RAC02-12SE/277/W
AC/DC Enclosed Power Supply (PSU), ITE, 1 Outputs, 2 W, 12 VDC, 167 mA
- Manufacturer: RECOM POWER
- Product type: AC / DC Enclosed Power Supplies
- Product Range: RAC02 Series
- No. of Outputs: 1Outputs
- Output Power Max: 2W
- Input Voltage VAC: 85V AC to 305V AC
- Power Supply Approvals: ITE
- Power Supply Output Type: Fixed
- Output Current - Output 1: 167mA
- Output Voltage - Output 1: 12VDC
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 13.88 € |
| Current stock | 10+ |
| Lead time | 30 days |
**![NOT RECOMMENDED FOR NEW DESIGNS] ! (LAST TIME BUY: 31[ST] MAR 2026)** Features • 35mW max. no load power consumption • Efficiency up to 76% **AC/DC Converter** • Isolated output 3kVAC / 1 minute Regulated • SCP, OVP protection • Wide operating temperature range: -40°C to +85°C Converter • Universal input 85-305VAC **RACC02-SE/277/W** ~~ee __~~ Description **2 Watt** The ultra-compact wired RAC02-SE/277/W modules are available with output voltages of 3.3, 5, 12 and 24V, and the input-to-output isolation is 3kVAC/1min. With a standby consumption of 35mW **Single 3** maximum, the mini power supplies are particularly suitable for energy-saving sleep mode and stand-by applications. Because of its compact design (height <18mm), it is a versatile solution for home **Output** automation and other similar applications. Complete with an integrated input filter, the series has enhanced EMI performance and complies with EN55032, class B. The mini power supplies are also protected against short circuit with fully automatic restart after the error has been solved. The converters are EN/UL60950-1 certified and come complete with a 3 year warranty. ## Selection Guide |Part|nom. Input|Output|Output|Efficiency|Max. Capacitive| |---|---|---|---|---|---| |Number|Voltage Range|Voltage|Current|typ(1)|Load(2)| ||[VAC]|[VDC]|[mA]|[%]|[µF]| |RAC02-3.3SE/277/W|100-277|3.3|600|67|12000| |RAC02-05SE/277/W|100-277|5.0|400|70|5500| |RAC02-12SE/277/W|100-277|12|167|73|500| |RAC02-24SE/277/W|100-277|24|83|76|160| ## Notes: Note1: Efficiency is tested at 230VAC and full load at +25°C ambient Note2: Max Cap Load is tested at nominal input and full resisitive load **==> picture [465 x 121] intentionally omitted <==** **----- Start of picture text -----**<br> RoHScompliant10 from 102+ REACHcompliant ERPcompliant<br>CERTIFIED<br>EN-60335-1<br>RAC02-__ SE/277/W E224736<br>| W ired @ Cem.<br>nom. Output Power<br>Output Voltage S ingle<br>— | Ti. Al<br>E<br>T T<br>O O<br>i<br>N N<br>a<br>N P N P<br>C C<br>S<br>l<br>V<br>R<br>V<br>R<br>H<br>A A<br>n<br>E<br>O<br>E<br>I I O<br>M M<br>p<br>L L<br>U<br>R R<br>D D<br>O<br>P P<br>c<br>O T O T<br>U U<br>p<br>O<br>C C<br>M M<br>E E<br>C C<br>L<br>e<br>E R E R<br>O T O T<br>a<br>R R<br>H<br>s<br>S<br>S<br>S<br>C C S<br>D<br>**----- End of picture text -----**<br> ## Model Numbering Ordering Examples: RAC02-05SE/277/W 2 Watt 5Vout Single Output Wired Version RAC02-12SE/277/W 2 Watt 12Vout Single Output Wired Version **PREFERRED ALTERNATIVES** Please consider these alternatives: **RAC04NE-K/277/W Series** IEC/EN60950-1 certified CAN/CSA-22.2 No. 60950 certified UL60950-1 certified EN60335-1 certified EN55032 certified EN55024 certified EN55014 certified CB Report REV.: 12/2026 PA-1 **www.recom-power.com** **(LAST TIME BUY: 31[ST] MAR 2026** ## **! NOT RECOMMENDED FOR NEW DESIGNS !** ## **RAC02-SE/277/W** ## **AC/DC Converter** ## **Series** Specifications (measured @ Ta= 25°C, nom. Vin (115/230VAC), full load and after warm-up unless otherwise stated) |BASIC CHARACTERISTICS|BASIC CHARACTERISTICS|BASIC CHARACTERISTICS|BASIC CHARACTERISTICS|BASIC CHARACTERISTICS|BASIC CHARACTERISTICS| |---|---|---|---|---|---| |Parameter|Condition||Min.|Typ.|Max.| |Input Voltage Range(3)|nom. Vin= 230VAC||85VAC<br>120VDC|277VAC|305VAC<br>430VDC| |Input Current|115VAC<br>230VAC|||47mA<br>30mA|| |Inrush Current|cold start at +25°C|115VAC<br>230VAC|||15A<br>30A| |No load Power Consumption|85-305VAC, 47-63Hz||||35mW| |Input Frequency Range|AC Input||47Hz||440Hz| |Minimum Load||||2%|| |Hold-up Time|115VAC||18ms||| |Internal OperatingFrequency|100% load at nominal Vin|||55kHz|| |Output Ripple and Noise(4)|3.3Vout<br>5, 12, 24Vout||||300mVp-p<br>250mVp-p| |Notes:<br>Note3:<br>The products were submitted for safety fles at AC-Input operation<br>Note4:<br>Ripple and Noise is the maximum peak-to-peak voltage value measured at the output with a 20MHz bandwidth, at rated line<br>voltage at full load. And with a 47µF low-ESR electrolytic capacitor in parallel with a 0.1µF ceramic capacitor across output<br>Effciency vs. Load<br>RAC02-05SE/277/W<br>0<br>10<br>20<br>30<br>40<br>50<br>60<br>70<br>80<br>90<br>100<br>100<br>80<br>60<br>40<br>90<br>70<br>50<br>30<br>20<br>10<br>0<br>Efficiency [%]<br>Output Load [%]<br>~~115VAC~~<br>230VAC<br>~~277VAC~~|||||| ## REGULATIONS |REGULATIONS||| |---|---|---| |Parameter|Condition|Value| |Output Voltage Tolerance(5)||±6.0% max.| |Line Regulation|low line to high line, full load|±1.5% max.| |Load Regulation|2% to 100% load|6.0% typ.| ## Notes: Note5: Includes initial voltage accuracy, thermal drift, line regulation and load regulation at rated input voltage and load conditions REV.: 12/2026 PA-2 **www.recom-power.com** **(LAST TIME BUY: 31[ST] MAR 2026** ## **! NOT RECOMMENDED FOR NEW DESIGNS !** ## **RAC02-SE/277/W** ## **AC/DC Converter** ## **Series** Specifications (measured @ Ta= 25°C, nom. Vin (115/230VAC), full load and after warm-up unless otherwise stated) |PROTECTIONS|||| |---|---|---|---| |Parameter|Type||Value| |Short Circuit Protection(SCP)|below 100mW||continuous, automatic recovery| |Over Voltage Protection(OVP)|zener diode clamp||110% - 140%| |Over Current Limit|||110% - 190%| |Over Voltage Category|||OVCII| |Isolation Voltage|I/P to O/P|tested for 1 minute|3kVAC| |Isolation Resistance|||1GΩ min.| |Leakage Current|85-305VAC, 47-63Hz||10µA max.| |Notes:|||| Note6: Refer to local wiring regulations if input over-current protection is also required. Recommended fuse: slow blow type Protection Circuit ## ENVIRONMENTAL |ENVIRONMENTAL||||| |---|---|---|---|---| |Parameter|Condition|||Value| |Operating Temperature Range(7)|full load, 230VAC<br>refer to derating graph|||-40°C to +75°C<br>-40°C to +85°C| |Maximum Case Temperature||||+105°C| |Thermal Impedance||||8.5K/W typ.| |OperatingHumidity|non-condensing|||5% - 95% RH max.| |MTBF|according to MIL-HDBK-217F, G.B.|+25°C|115VAC<br>230VAC|2238 x 103hours<br>1670 x 103hours| Notes: Note7: At low input voltage (85-140VAC) and temperature below -25°C the RAC02-3.3SE/277/W and RAC02-05SE/277/W, will not start ## Derating Graph **==> picture [486 x 207] intentionally omitted <==** **----- Start of picture text -----**<br> @ 85-140VAC @ 140-305VAC<br>100 100<br>90 90<br>80 80<br>70 70<br>YY<br>60 Up 4 60<br>ty<br>50 Gy Up 50<br>Hy<br>40 Up 4 40<br>30 YH) 30<br>HyUp “ 3.3V and 5V all models<br>20 YY) all other models 20<br>10 YY 10<br>Yt<br>0 0<br>-40 -20 0 20 40 60 80 100 120 -40 -20 0 20 40 60 80 100 120<br>-25 75 85 75 85<br>Ambient Temperature [°C] Ambient Temperature [°C]<br>Output Load [%] Output Load [%]<br>**----- End of picture text -----**<br> REV.: 12/2026 PA-3 **www.recom-power.com** **! NOT RECOMMENDED FOR NEW DESIGNS !** **(LAST TIME BUY: 31[ST] MAR 2026** ## **RAC02-SE/277/W** ## **AC/DC Converter** ## **Series** Specifications (measured @ Ta= 25°C, nom. Vin (115/230VAC), full load and after warm-up unless otherwise stated) |SAFETY AND CERTIFICATIONS|SAFETY AND CERTIFICATIONS|| |---|---|---| |Certifcate Type(Safety)|Report / File Number|Standard| |Information Technology Equipment, General Requirements for Safety|L0339L26-CB-1-B4|IEC60950-1:2005 2nd Edition + A2:2013<br>EN60950-1:2006 + A2:2013| |Information Technology Equipment, General Requirements for Safety|E224736-X1-A24-UL|UL No. 60950-1, 2nd Edition, 2014<br>CAN/CSA-C22.2 No. 60950-1-07, 2nd Edition, 2014| |Household and similar electrical appliances, General requirements|L0339L26-B2-L|EN60335-1:2012+A11:2014| |EAC Safety of Low Voltage Equipment|RU-AT.37.02367|TP TC 004/2011| |RoHS2||RoHS-2011/65/EU + AM-2015/863| |||| |EMC Compliance(Industrial)|Condition|Standard / Criterion| |Electromagnetic compatibility of multimedia equipment -<br>Emission requirements|1502CE17|EN55032:2015, Class B| |Information technology equipment - Immunity characteristics -<br>Limits and methods of measurement||EN55024:2010| |ESD Electrostatic discharge immunity test|±8.0kV air, ±4.0kV contact|EN61000-4-2:2009, Criteria B| |Radiated, radio-frequency, electromagnetic feld immunity test|3V/m|EN61000-4-3:2006 + A2:2010, Criteria A| |Fast Transient and Burst Immunity|AC Power Port: ±1.0kV|EN61000-4-4:2012, Criteria A| |Power Magnetic Field Immunity|50Hz, 1 A/m|EN61000-4-8:2010, Criteria A| |Voltage Dips and Interruption|Voltage Dips: >95% reduction<br>>30% reduction<br>Interruption: >95%|EN61000-4-11:2004, Criteria A<br>EN61000-4-11:2004, Criteria A<br>EN61000-4-11:2004,Criteria B| |Limits of Voltage Fluctuations & Flicker||EN61000-3-3:2013| |||| |EMC Compliance(Household)|Condition|Standard / Criterion| |Electromagnetic compatibility of multimedia equipment – Emission<br>Requirements|E16113001|EN55014-1:2006+A2:2011| |Information technology equipment - Immunity characteristics -<br>Limits and methods of measurement||EN55014-2:2015| |ESD Electrostatic discharge immunity test|±8.0kV air, ±4.0kV contact|IEC61000-4-2:2008, Criteria A| |Radiated, radio-frequency, electromagnetic feld immunity test|3V/m|IEC61000-4-3:2006 + A2:2010, Criteria A| |Fast Transient and Burst Immunity|AC Power Port ±1.0kV<br>DC Output±0.5kV|IEC61000-4-4:2012, Criteria A| |Surge Immunity|AC Power Port L-N ±2.0kV<br>DC OutputL-N ±1.0kV|IEC61000-4-5:2014, Criteria B| |Immunity to conducted disturbances, induced by radio-frequencyfelds|AC Power Port 3V, DC Output 3V|IEC61000-4-6:2013, Criteria A| |Voltage Dips and Interruption|Voltage Dips: >95% reduction<br>>30% reduction<br>Interruption: >95%|IEC61000-4-11:2004, Criteria B<br>IEC61000-4-11:2004, Criteria C<br>IEC61000-4-11:2004,Criteria C| |Limits of Harmonic Current Emissions||EN61000-3-2:2014| |Limits of Voltage Fluctuations & Flicker||EN61000-3-3:2013| |DIMENSION AND PHYSICAL CHARACTERISTICS|DIMENSION AND PHYSICAL CHARACTERISTICS|DIMENSION AND PHYSICAL CHARACTERISTICS| |---|---|---| |Parameter|Type|Value| |Material|case<br>potting|black plastic, (UL94V-0)<br>epoxy,(UL94V-0)| |Dimension(LxWxH)||33.7 x 22.2 x 17.75mm| |Weight||25gtyp.| |continued on nextpage||| REV.: 12/2026 PA-4 **www.recom-power.com** **! NOT RECOMMENDED FOR NEW DESIGNS !** **(LAST TIME BUY: 31[ST] MAR 2026** ## **RAC02-SE/277/W** ## **AC/DC Converter** ## **Series** Specifications (measured @ Ta= 25°C, nom. Vin (115/230VAC), full load and after warm-up unless otherwise stated) **==> picture [510 x 381] intentionally omitted <==** **----- Start of picture text -----**<br> Dimension Drawing (mm)<br>embossed logo<br>33.7 22.2<br>5.0<br>Wired Connections<br> Wired Color Type Function<br> 1, blue UL-1015, AWG22 VAC in (N)<br> 2, brown UL-1015, AWG22 VAC in (L)<br>Ø2.40 Ø1.56 Ø0.76 Ø0.76 3, black 4, red ULUL--1430, AWG22 1430, AWG22 +Vout-Vout<br>Tolerance: xx.x= ±0.5mm<br> xx.xx= ±0.35mm<br>L brown Bottom View<br>+red<br>18.0 tc<br>N blue -black<br>17.7<br>0.75<br>85.0<br>10 ±3<br>7.0<br>**----- End of picture text -----**<br> |||| |---|---|---| |PACKAGING INFORMATION||| |Parameter|Type|Value| |PackagingDimension(LxWxH)|cardboard box|520.0 x 195.0 x 68.0mm| |Packaging Quantity||30pcs| |Storage Temperature Range||-40°C to +85°C| The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. REV.: 12/2026 PA-5 **www.recom-power.com**
Updated at February 9, 2023
RECOM Power is a globally recognized manufacturer specializing in standard and customized power conversion solutions. Headquartered in Austria with state-of-the-art research and development facilities, the company has built a strong reputation for innovation and reliability. Operating from ISO 9001 and IATF 16949 certified manufacturing sites, RECOM delivers premium power supplies engineered for demanding applications across IoT, Industry 4.0, medical technology, and transportation. The core of our RECOM Power portfolio is dedicated to advanced power and line protection, featuring an extensive selection of high-performance AC/DC converters. These modules are designed to provide efficient, stable power distribution for a wide array of industrial and commercial electronics. In addition to general-purpose power supplies, we offer a robust range of AC/DC LED power supplies specifically optimized to meet the stringent efficiency and lifespan requirements of modern lighting systems. To support comprehensive power architecture design, our selection also includes highly efficient DC/DC converters ideal for precise voltage regulation in complex circuits. Furthermore, we provide specialized passive components such as RECOM power inductors, ensuring engineers have access to the critical, high-quality components required to develop resilient and optimized power delivery systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →