RAC01-15SC
AC/DC PCB Mount Power Supply (PSU), ITE, 1 Output, 1 W, 15 VDC, 67 mA
- Manufacturer: RECOM POWER
- Product type: AC / DC PCB Mount Power Supplies
- Depth: 33.7mm
- Width: 22.2mm
- Height: 17.75mm
- Product Range: RAC01 Series
- No. of Outputs: 1 Output
- Output Power Max: 1W
- Input Voltage VAC: 80V AC to 264V AC
- Input Voltage AC Max: 264V
- Input Voltage AC Min: 80V
- Power Supply Approvals: ITE
- Power Supply Output Type: Fixed
- Output Current - Output 1: 67mA
- Output Voltage - Output 1: 15VDC
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 13.22 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **![NOT RECOMMENDED FOR NEW DESIGNS] ![[TH]]** **(LAST TIME BUY: 12[[TH]] AUG 2022)** • Compact low profile AC-DC power supply **==> picture [81 x 19] intentionally omitted <==** **----- Start of picture text -----**<br> Features<br>**----- End of picture text -----**<br> - 30mW no load power consumption • Class II power supply with 3kVAC isolation ## Regulated Converters • Universal input voltage range (80~264VAC) • Low output ripple/noise • EN, UL and CE certified ## Description The RAC01-SC and RAC02-SC series are ultra-compact universal input AC/DC power modules for PCB mounting. They feature high efficiency, low standby power, high operating temperature, soft start and short-circuit protection as well as a built-in EMC Class B filter. Output voltages range from 3.3VDC to 24VDC. ## **AC/DC Converter** ## **RAC01-C RAC02-C** ## **1-2 Watt 3** <i> **Single Output** ## Selection Guide |Part|Input|Output|Output|Efficiency|Max. Capacitive| |---|---|---|---|---|---| |Number|Voltage Range|Voltage|Current|typ|Load(1,2)| ||[VAC]|[VDC]|[mA]|[%]|[µF]| |RAC01-3.3SC|80-264|3.3|300|65|2200| |RAC01-05SC|80-264|5|200|68|1600| |RAC01-09SC|80-264|9|111|70|470| |RAC01-12SC|80-264|12|83|72|180| |RAC01-15SC|80-264|15|67|72|180| |RAC01-24SC|80-264|24|42|73|68| ||||||| |RAC02-3.3SC|80-264|3.3|600|66|2700| |RAC02-05SC|80-264|5|400|70|2000| |RAC02-09SC|80-264|9|222|72|560| |RAC02-12SC|80-264|12|167|74|200| |RAC02-15SC|80-264|15|133|74|200| |RAC02-24SC|80-264|24|83|77|68| ## Notes: Note1: Measured @ 230VAC / 50Hz / Ta=25°C with constant resistive load Note2: If used @ 115VAC / 60Hz with full load, maximum capacitive load is less, please contact techsupportAT@recom-power.com for detailed information ## Model Numbering **==> picture [139 x 79] intentionally omitted <==** **----- Start of picture text -----**<br> VA RoHScompliant10 from 10 eesm 2+ ul REACHcompliant y, ERPcompliant y<br>*<br>CERTIFIEDEN-60335-1 C<br>E224736<br>E<br>T T<br>O O<br>i<br>N N<br>a<br>N P N P<br>C C<br>S<br>l<br>V<br>R<br>V<br>R<br>H<br>A A<br>n<br>E<br>O<br>E<br>I O I<br>M M<br>p<br>L L<br>U<br>R R<br>D D<br>O<br>P P<br>c<br>O T O T<br>U U<br>p<br>O<br>C C<br>M M<br>E E<br>C C<br>L<br>e<br>E R E R<br>O T O T<br>a<br>R R<br>H<br>s<br>S<br>S<br>S<br>C S C<br>D<br>**----- End of picture text -----**<br> ## RAC0_-__ _C nom. Output Power[(3)] **S** ingle nom. Output Voltage ## **PREFERRED ALTERNATIVES** ## Notes: Please consider these alternatives: Note3: „1“ for 1 Watt, „2“ for 2 Watt **RAC02E-K/277** Ordering Examples: RAC01-12SC 1 Watt 12Vout Single Output RAC01-05SC 1 Watt 5Vout Single Output RAC02-3.3SC 2 Watt 3.3Vout Single Output RAC02-24SC 2 Watt 24Vout Single Output EN60950-1 certified UL60950-1 certified *EN60335-1 certified (only 2W version) REV.: 2/2022 PA-1 **www.recom-power.com** **! NOT RECOMMENDED FOR NEW DESIGNS !** ## **AC/DC Converter** ## **(LAST TIME BUY: 12[TH] AUG 2022) RAC01-C RAC02-C** Specifications (measured at Ta= 25°C, nominal input voltage, full load otherwise noted) |BASIC CHARACTERISTICS|BASIC CHARACTERISTICS|||||| |---|---|---|---|---|---|---| |Parameter||Condition||Min.|Typ.|Max.| |Input Voltage Range(4)||nom. Vin = 230VAC||80VAC<br>115VDC||264VAC<br>370VDC| |Input Current||RAC01-C|115VAC<br>230VAC|||34mA<br>23mA| |||RAC02-C|115VAC<br>230VAC|||55mA<br>36mA| |Inrush Current||<0.5ms cold start at 25°C|115VAC<br>230VAC|||30A<br>60A| |No load Power Consumption||115VAC<br>230VAC|||30mW<br>80mW|| |Input FrequencyRange||AC Input||47Hz||63Hz| |Minimum Load(5)|||||0%|| |Start-up Time||115VAC<br>230VAC|||3ms<br>1.5ms|| |Rise Time||115VAC/ 230VAC|||20ms|| |Hold-up time||115VAC<br>230VAC|||10ms<br>60ms|| |Internal OperatingFrequency||100% load at nominal Vin|||30kHz|| |Output Ripple and Noise(6)||20MHz BW|3.3Vout<br>all others|||150mVp-p<br>100mVp-p| |continued on next page<br>Effciency vs. Load<br>0<br>10<br>20<br>30<br>40<br>50<br>60<br>70<br>80<br>90<br>100<br>100<br>80<br>60<br>40<br>90<br>70<br>50<br>30<br>20<br>10<br>0<br>Efficiency [%]<br>Output Load [%]<br>115VAC<br>~~230VAC~~<br>Notes:<br>Note4: Refer to line derating graph on page 3<br>Note5: Operation below 10% load won‘t harm the converter, but specifcations may not be met<br>Note6: Ripple and Noise is the maximum peak-to-peak voltage value measured at the output with a 20MHz bandwidth, at rated line voltage and full load<br>RAC01-05SC<br>RAC01-12SC<br>0<br>10<br>20<br>30<br>40<br>50<br>60<br>70<br>80<br>90<br>100<br>100<br>80<br>60<br>40<br>90<br>70<br>50<br>30<br>20<br>10<br>0<br>Efficiency [%]<br>Output Load [%]<br>115VAC<br>~~230VAC~~|Notes:|||||| REV.: 2/2022 PA-2 **www.recom-power.com** ## **! NOT RECOMMENDED FOR NEW DESIGNS !** ## **AC/DC Converter** ## **(LAST TIME BUY: 12[TH] AUG 2022) RAC01-C RAC02-C** Specifications (measured at Ta= 25°C, nominal input voltage, full load otherwise noted) **==> picture [525 x 475] intentionally omitted <==** **----- Start of picture text -----**<br> RAC02-05SC RAC02-12SC<br>100 100<br>90 90<br>80 80<br>70 70<br>60 60<br>50 50<br>40 40<br>115VAC 115VAC<br>30 230VAC 30 230VAC<br>20 20<br>10 10<br>0 0<br>0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100<br>Output Load [%] Output Load [%]<br>Line Derating<br>100<br>90<br>80<br>70<br>60<br>50<br>40<br>30<br>20<br>10<br>0<br>80 100 120 140 160 180 200 220 240 260 264<br>90<br>Input Voltage [VAC]<br>Efficiency [%] Efficiency [%]<br>Output Load [%]<br>**----- End of picture text -----**<br> ## REGULATIONS |REGULATIONS|REGULATIONS|REGULATIONS| |---|---|---| |Parameter|Condition|Value| |Output Accuracy||±5.0% typ.| |Line Regulation|low line to high line|±2.0% max.| |Load Regulation|10% to 100% load|6.0% max.| |continued on next page||| REV.: 2/2022 PA-3 **www.recom-power.com** ## **! NOT RECOMMENDED FOR NEW DESIGNS !** ## **AC/DC Converter** ## **(LAST TIME BUY: 12[TH] AUG 2022) RAC01-C RAC02-C** Specifications (measured at Ta= 25°C, nominal input voltage, full load otherwise noted) **==> picture [499 x 423] intentionally omitted <==** **----- Start of picture text -----**<br> Deviation vs. Load<br>RAC01-05SC RAC01-12SC<br>16 6<br>14 5<br>12 115VAC 115VAC<br>4<br>230VAC 230VAC<br>10<br>3<br>8<br>2<br>6<br>1<br>4<br>2 0<br>0 -1<br>-2 -2<br>0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100<br>Output Load [%] Output Load [%]<br>RAC02-05SC RAC02-12SC<br>16 6<br>14 5<br>12 115VAC 115VAC<br>4<br>230VAC 230VAC<br>10<br>3<br>8<br>2<br>6<br>1<br>4<br>0<br>2<br>0 -1<br>-2 -2<br>0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100<br>Output Load [%] Output Load [%]<br>Deviation [%] Deviation [%]<br>Deviation [%] Deviation [%]<br>**----- End of picture text -----**<br> |PROTECTIONS|PROTECTIONS|||| |---|---|---|---|---| |Parameter||Type||Value| |Short Circuit Protection(SCP)||below 100mW||Hiccupmode, automatic recovery| |Over Voltage Category||||OVCII| |Class of Equipment||||ClassII| |Isolation Voltage||I/P to O/P|rated for 1 minute|3kVAC| |Isolation Resistance||||1GWmin.| |Isolation Capacitance||||1000pF max.| |Insulation Grade||||reinforced| |Leakage Current||||0.25mA max.| ||Notes:|||| REV.: 2/2022 PA-4 **www.recom-power.com** **! NOT RECOMMENDED FOR NEW DESIGNS !** ## **AC/DC Converter** ## **(LAST TIME BUY: 12[TH] AUG 2022) RAC01-C RAC02-C** Specifications (measured at Ta= 25°C, nominal input voltage, full load otherwise noted) **==> picture [374 x 116] intentionally omitted <==** **----- Start of picture text -----**<br> Protection Circuit<br>L N<br>F VACin (L) +Vout +Vout<br>VACin(N) -Vout -Vout<br>U<br>**----- End of picture text -----**<br> |ENVIRONMENTAL|ENVIRONMENTAL|ENVIRONMENTAL|ENVIRONMENTAL|ENVIRONMENTAL|ENVIRONMENTAL|ENVIRONMENTAL|ENVIRONMENTAL|ENVIRONMENTAL|ENVIRONMENTAL|ENVIRONMENTAL||||||| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| |Parameter||Condition||||||||||||||Value| |Operating Temperature Range||@ natural convection 0.1m/s||||||full load|||RAC01-C|||||-25°C to +80°C| ||||||||||||RAC02-C|||||-25°C to +75°C| |||||||||refer to derating graph||||||||-25°C to +85°C| |Maximum Case Temperature||||||||||||||||+95°C| |Temperature Coeffcient||+25°C to +75°C||||||||||||||0.1%°C| |Thermal Impedance||0.1m/s,horizontal||||||||||||||27°C/W| |OperatingAltitude||||||||||||||||2000m| |OperatingHumidity||non-condensing||||||||||||||95% RH max.| |Pollution Degree||||||||||||||||PD2| |Vibration||||||||||||||||accordingto MIL-STD-810F| |MTBF||according to MIL-HDBK-217F, G.B.||||||+25°C<br>+55°C<br>+80°C||||||||666 x 103hours<br>395 x 103hours<br>125 x 103hours| |Derating Graph<br>(@ Chamber and natural|-25<br>100<br>80<br>60<br>40<br>90<br>70<br>50<br>30<br>20<br>10<br>0<br>Output Load [%]<br>convection 0.1m/s)<br>Notes:|||||||||||||||| |||||||||||||||||| |||||||||||||||||| |||||||||||||||||| |||||||||||||||||| |||||||||||||||||| |||||||||||||||||| ||||||||~~-C~~|||||||||| |||||||~~RAC0~~||||||||||| |||||||RAC01|-C|||||||||| |||||||||||||||||| |||||||||||||||||| |||||||||||||||||| |||||||||||||||||| REV.: 2/2022 PA-5 **www.recom-power.com** **! NOT RECOMMENDED FOR NEW DESIGNS !** **(LAST TIME BUY: 12[TH] AUG 2022)** ## **AC/DC Converter** ## **RAC01-C RAC02-C** Specifications (measured at Ta= 25°C, nominal input voltage, full load otherwise noted) |SAFETY AND CERTIFICATIONS|SAFETY AND CERTIFICATIONS|SAFETY AND CERTIFICATIONS|SAFETY AND CERTIFICATIONS| |---|---|---|---| |Certifcate Type(Safety)||Report / File Number|Standard| |Information Technology Equipment - General Requirments for Safety||1606038|EN60950-1:2006 + A2:2013<br>IEC60950-1:2005,2nd Edition + A2:2013| |Information TechnologyEquipment - General Requirments for Safety (CB Scheme)||L0339m10-CB-1-B1|IEC60950-1:2005, 2nd Edition + A2:2013| |Information Technology Equipment, General Requirements for Safety||E224736-A5|UL60950-1, 2nd Edition, 2007<br>CSA C22.2 60950-1,2nd Edition,2007| |Household and similar electrical appliances - Safety- Part 1: General requirements(10)||L0339L26-B2-L|EN60335-1:2012 + A11:2014| |EAC Safetyof Low Voltage Equipment||RU-AT.49.09571|TP TC 004/2011| |RoHS2|||RoHS-2011/65/EU + AM-2015/863| ||||| |EMC Compliance(Industrial)||Condition|Standard / Criterion| |Electromagnetic compatibilityof multimedia equipment – Emission Requirements|||EN55032:2015| |Information technology equipment - Immunity characteristics - Limits and methods<br>of measurement|||EN55024:2010 + A1:2015| |ESD Electrostatic discharge immunitytest||±8kV air, ±4kV contact|IEC61000-4-2:2008, Criteria A| |Radiated, radio-frequency, electromagnetic feld immunity test||3V/m|IEC61000-4-3:2006 + A2:2010, Criteria A| |Fast Transient and Burst Immunity||AC Power Port: ±1.0kV|IEC61000-4-4:2012, Criteria A| |Surge Immunity||AC Power Port: L-N ±1.0kV|IEC61000-4-5:2005, Criteria A| |Immunity to conducted disturbances, induced by radio-frequency felds||AC Power Port 3Vr.m.s.|IEC61000-4-6:2008, Criteria A| |Voltage Dips and Interruptions||Voltage Dips >95%<br>Voltage Dips 30%<br>Voltage Interruptions >95%|IEC61000-4-11:2004, Criteria A<br>IEC61000-4-11:2004, Criteria A<br>IEC61000-4-11:2004,Criteria C| |Limits of Voltage Fluctuations & Flicker|||EN61000-3-3:2013| ||||| |EMC Compliance(Household)only2Watt version||Condition|Standard / Criterion| |Electromagnetic compatibility - Requirements for household appliances, electric<br>tools and similar apparatus - Part 1: Emission|||EN55014-1:2006+A2:2011| |Information technology equipment - Immunity characteristics - Limits and methods<br>of measurement|||EN55014-2:2015| |ESD Electrostatic discharge immunitytest||±8kV air, ±4kV contact|IEC61000-4-2:2008, Criteria A| |Radiated, radio-frequency, electromagnetic feld immunity test||3V/m|IEC61000-4-3:2006 + A2:2010, Criteria A| |Fast Transient and Burst Immunity||AC Power Port: ±1kV<br>DC Output: ±0.5kV|EC61000-4-4:2012, Criteria A| |Surge Immunity||AC Power Port:L to N ±2kV<br>DC Output: L to N ±1kV|IEC61000-4-5:2014, Criteria B| |Immunity to conducted disturbances, induced by radio-frequency felds||3 Vr.m.s.|IEC61000-4-6:2013, Criteria A| |Voltage Dips and Interruptions||Voltage Dips >95%<br>Voltage Dips 30%<br>Voltage Interruptions >95%|IEC61000-4-11:2004, Criteria B<br>IEC61000-4-11:2004, Criteria C<br>IEC61000-4-11:2004,Criteria C| |Limits of Harmonic Current Emissions|||EN61000-3-2:2014| |Limits of Voltage Fluctuations & Flicker|||EN61000-3-3:2013| ||Notes:<br>Note10: RAC01-C series is excluded||| REV.: 2/2022 PA-6 **www.recom-power.com** **(LAST TIME BUY: 12[TH] AUG 2022)** ## **! NOT RECOMMENDED FOR NEW DESIGNS !** ## **AC/DC Converter** ## **RAC01-C RAC02-C** Specifications (measured at Ta= 25°C, nominal input voltage, full load otherwise noted) **==> picture [526 x 526] intentionally omitted <==** **----- Start of picture text -----**<br> DIMENSION AND PHYSICAL CHARACTERISTICS<br>Parameter Type Value<br>case black plastic (UL94V-0)<br>Material potting silicone (UL94V-0)<br>PCB FR4, (UL94V-1)<br>Dimension (LxWxH) 33.7 x 22.2 x 17.75mm<br>Weight 25g typ.<br> Dimension Drawing (mm)<br>33.7<br>embossed logo<br>33.4 21.9<br>Pin Connections<br> Pin # Single<br> 1 VAC in (N)<br> 2 VAC in (L)<br> 3 -Vout<br> 4 +Vout<br>Tolerance: xx.x= ±0.5mm<br> xx.xx= ±0.25mm<br>5.0<br>Ø 0.6 [±0.1]<br>28.0 Recommended Footprint Details<br>1 Top View 3<br>2<br>Bottom View 4<br>Leave Clear<br>4<br>of PCB Traces<br>1 3<br>2<br>2.54<br>Allow 5mm clearance around converter for air circulation<br>22.2<br>17.75<br>±1.0<br>6.1 0.75<br>7.62<br>15.24 2.54<br>**----- End of picture text -----**<br> |||| |---|---|---| |PACKAGING INFORMATION||| |Parameter|Type|Value| |PackagingDimension(LxWxH)|tube|520.0 x 37.0 x 28.0mm| |PackagingQuantity||22pcs| |Storage Temperature Range||-40°C to +100°C| |Storage Humidity|non-condensing|95% RH max.| The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. REV.: 2/2022 PA-7 **www.recom-power.com**
Updated at February 9, 2023
RECOM Power is a globally recognized manufacturer specializing in standard and customized power conversion solutions. Headquartered in Austria with state-of-the-art research and development facilities, the company has built a strong reputation for innovation and reliability. Operating from ISO 9001 and IATF 16949 certified manufacturing sites, RECOM delivers premium power supplies engineered for demanding applications across IoT, Industry 4.0, medical technology, and transportation. The core of our RECOM Power portfolio is dedicated to advanced power and line protection, featuring an extensive selection of high-performance AC/DC converters. These modules are designed to provide efficient, stable power distribution for a wide array of industrial and commercial electronics. In addition to general-purpose power supplies, we offer a robust range of AC/DC LED power supplies specifically optimized to meet the stringent efficiency and lifespan requirements of modern lighting systems. To support comprehensive power architecture design, our selection also includes highly efficient DC/DC converters ideal for precise voltage regulation in complex circuits. Furthermore, we provide specialized passive components such as RECOM power inductors, ensuring engineers have access to the critical, high-quality components required to develop resilient and optimized power delivery systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →