RAC01-12SGA
AC/DC PCB Mount Power Supply (PSU), ITE & Household, 1 Output, 1 W, 12 VDC, 83 mA
- Manufacturer: RECOM POWER
- Product type: AC / DC PCB Mount Power Supplies
- No. of Outputs:1 Output; Output Power Max:1W; Output Voltage - Output 1:12V; Output Current - Output 1:83mA; Output Voltage - Output 2:-; Output Current - Output 2:-; Output Voltage - Ou
- SVHC: No SVHC (04-Feb-2026)
- Depth: 33.7mm
- Width: 22.2mm
- Height: 19mm
- Product Range: RAC01-GA Series
- No. of Outputs: 1 Output
- Output Power Max: 1W
- Input Voltage VAC: 85V AC to 264V AC
- Input Voltage AC Max: 264V
- Input Voltage AC Min: 85V
- Power Supply Output Type: Fixed
- Output Current - Output 1: 83mA
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 12VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Power Supply Applications: ITE & Household
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 6.21 € |
| Current stock | 10+ |
| Lead time | 30 days |
**==> picture [133 x 12] intentionally omitted <==** **----- Start of picture text -----**<br> • Universal input 85-264VAC<br>**----- End of picture text -----**<br> ## Features Regulated Converter • <150mW No load power consumption • Class II installations (without FG) • -25°C to +80°C Operating temperature • Continuous SCP, OCP • EN/IEC/UL60950, EN/IEC/UL62368 & EN60335-1 certified ## Description The RAC01-GA series are low cost AC/DC power supplies, ideal for PCB mounted, compact, board level industrial applications. They feature universal AC input voltage range, regulated and short-circuit-proof isolated DC outputs, low standby power consumption and -25°C to +80°C operating temperature range. The RAC01-GA have a built-in Class A / FCC Part 15 EMC filter, are certified to EN60335, EN60950 and EN62368 safety standards and come with a three year warranty. ## **AC/DC Converter** ## **RAC01-GA** **1 Watt Single Output EMC Class A** ## Selection Guide |Part|Input|Output|Output|Efficiency|Max. Capacitive| |---|---|---|---|---|---| |Number|Voltage Range|Voltage|Current|typ(1)|Load(2)| ||[VAC]|[VDC]|[mA]|[%]|[µF]| |RAC01-05SGA|85-264|5|200|63|500| |RAC01-12SGA|85-264|12|83|68|200| |On Request|||||| |RAC01-3.3SGA<br>85-264<br>3.3<br>303<br>63<br>500<br>RAC01-15SGA<br>85-264<br>15<br>66<br>63<br>200<br>RAC01-24SGA(3)<br>85-264<br>24<br>42<br>63<br>200<br>~~ee~~|||||| Notes: Note1: Measured with all input voltages at 25°C with constant resistant mode at full load Note2: Max Cap Load is tested at nominal input and full resisitive load Note3: Minimum order quantity ≥2000pcs **==> picture [141 x 129] intentionally omitted <==** **----- Start of picture text -----**<br> RoHScompliant10 from 102+ REACHcompliant ERPLOT6 compliant<br>CERTIFIED<br>EN-60335-1<br>bo<br>SCHEa E224736 WeaAL<br>E<br>T T<br>O O<br>i<br>N N<br>a<br>N P N P<br>C C<br>S<br>l<br>V<br>R<br>V<br>R<br>H<br>A A<br>n<br>E<br>O<br>E<br>I O I<br>M M<br>p<br>L L<br>U<br>R R<br>D D<br>O<br>P P<br>c<br>O T O T<br>U U<br>p<br>O<br>C C<br>M M<br>E E<br>C C<br>L<br>e<br>E R E R<br>O T O T<br>a<br>R R<br>H<br>s<br>S<br>S<br>S<br>C S C<br>D<br>**----- End of picture text -----**<br> Model Numbering ~~De~~ RAC01-__ SGA nom. Output Power EMC Class A nom. Output Voltage TS }Tt **S** ingle Ordering Examples: RAC01-12SGA 12Vout Single Output EMC Class A **RAC02E-K/277** Se IEC/EN60950-1 certified CAN/CSA-C22.2 No. 62368 certified UL62368-1 certified IEC/EN62368-1 certified EN60335-1 certified EN55032 compliant EN55024 compliant CB Report pending REV.: 6/2023 PA-1 **www.recom-power.com** ## **RAC01-GA** ## **AC/DC Converter** ## **Series** Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) |BASIC CHARACTERISTICS|BASIC CHARACTERISTICS|||||||| |---|---|---|---|---|---|---|---|---| |Parameter|||Condition|||Min.|Typ.|Max.| |Internal Input Filter||||||||Pi-type| |Input Voltage Range(4,5,6)|||nom. Vin= 230VAC|||85VAC|230VAC|264VAC| |Input Current|||115VAC<br>230VAC||||25mA<br>18mA|30mA<br>20mA| |Inrush Current|||cold start at 25°C|115VAC<br>230VAC||||30A<br>40A| |No load Power Consumption||||||||150mW| |Input Frequency Range||||||47Hz||63Hz| |Minimum Load||||||0%||| |Power Factor|||115VAC, 230VAC|||0.4||0.6| |Start-up Time|||115VAC<br>230VAC|||||1s<br>2s| |Hold-up time|||115VAC<br>230VAC|||||18ms<br>80ms| |Internal OperatingFrequency|||100% load at nominal Vin||||65kHz|| |Output Ripple and Noise|||20MHz BW|0°C to 80 °C|5Vout<br>12Vout|||100mVp-p<br>200mVp-p| |||||-25 °C to 0 °C|5Vout<br>12Vout|||200mVp-p<br>300mVp-p| |Effciency vs.<br><br>100<br>80<br>60<br>40<br>90<br>70<br>50<br>30<br>20<br>10<br>0<br>Efficiency [%]|Load<br>0<br>10<br>20<br>30<br>40<br>50<br>60<br>70<br>80<br>90<br>100<br>Output Load [%]<br>115VAC<br>230VAC<br>0<br>10<br>20<br>30<br>40<br>50<br>60<br>70<br>80<br>90<br>100<br>100<br>80<br>60<br>40<br>90<br>70<br>50<br>30<br>20<br>10<br>0<br>Efficiency [%]<br>Output Load [%]<br>115VAC<br>230VAC<br>RAC01-12SGA<br>RAC01-05SGA<br>Notes:<br>Note4: No proper operation with DC input voltage<br>Note5: The products were submitted for safety fles at AC-Input operation<br>Note6: Refer to“Line Derating”|Notes:||||||| REV.: 6/2023 PA-2 **www.recom-power.com** ## **RAC01-GA** ## **AC/DC Converter** ## **Series** Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) **==> picture [526 x 296] intentionally omitted <==** **----- Start of picture text -----**<br> REGULATIONS<br>Parameter Condition Value<br>Output Accuracy -25°C to +80°C ±6.0% max.<br>Line Regulation -25°C to +80°C ±2.0% max.<br>Load Regulation -25°C to +80°C 6.0% max.<br>Deviation vs. Load<br>RAC01-05SGA RAC01-12SGA<br>6 6<br>4 4<br>115VAC 115VAC<br>2 230VAC 2 230VAC<br>0 0<br>-2 -2<br>-4 -4<br>-6 -6<br>0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100<br>Output Load [%] Output Load [%]<br>Deviation [%] Deviation [%]<br>**----- End of picture text -----**<br> |PROTECTIONS|PROTECTIONS|||| |---|---|---|---|---| |Parameter||Type||Value| |Input Fuse(7)||internal||fusible resistor, 1Ω/1W| |Short Circuit Protection(SCP)||below 100mΩ||continuous, auto recovery| |Over Voltage Category||||OVCII| |Over Current Protection (OCP)||5Vout<br>12Vout||0.22A - 0.5A, hiccup mode<br>0.25A - 0.91A, hiccupmode| |Class of Equipment||||Class II| |Isolation Voltage(8)||I/P to O/P|rated for 1 minute|3kVAC| |Isolation Resistance||||100MΩ min.| |Insulation Grade||||reinforced| |Leakage Current||I/P to O/P||0.25mA max.| |Notes:<br>Note7: Refer to local wiring regulations if input over-current protection is also required<br>Note8: For repeat Hi-Pot testing, reduce the time and/or the test voltage<br>Note9: For operation at 230VAC, an external MOV is recommended. The Varistor should comply with IEC-61051-2. e.g. EPCOS S14 series<br>-Vout<br>+Vout<br>L<br>N<br>+Vout<br>VACin(L)<br>VACin(N)<br>-Vout<br>**F**<br>Var<br>U<br>Protection Circuit|Notes:|||| REV.: 6/2023 PA-3 **www.recom-power.com** ## **RAC01-GA** ## **AC/DC Converter** ## **Series** Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) |ENVIRONMENTAL|ENVIRONMENTAL|ENVIRONMENTAL|ENVIRONMENTAL|ENVIRONMENTAL| |---|---|---|---|---| |Parameter|Condition|||Value| |Operating Temperature Range|@ natural convection 0.1m/s|full load||-25°C to +70°C| |||refer to”DeratingGraph”||-25°C to +80°C| |Maximum Case Temperature||||+120°C| |Temperature Coeffcient||||0.03%/K| |OperatingAltitude(10)||||4000m| |OperatingHumidity|non-condensing|||5% - 90% RH max.| |Pollution Degree||||PD2| |Shock||||10-150Hz, 2G 10min./1cycle, period 60min. each along x,y,z axes| |Vibration|accordingto MIL-STD-202G|||20G/11ms pulse, 3 times at each x, y, z axes| |MTBF(11)|according to MIL-HDBK-217F, method 2||+25°C<br>+70°C|1691 x 103hours<br>424 x 103hours| |-25<br>-10<br>5<br>20<br>35<br>50<br>80<br>95<br>100<br>80<br>60<br>40<br>90<br>70<br>50<br>30<br>20<br>10<br>0<br>Output Load [%]<br>Ambient Temperature [°C]<br>70<br>65<br>Derating Graph<br>(@ Chamber and natural convection 0.1m/s)<br>Notes:<br>Note10: Recognized by UL for safe operation up to 4000m. High altitude operation may impact the performance and lifetime.<br>Contact TechsupportAT@recom-power.com for advice<br>Note11: Based on calculation for 5Vout<br>Line Derating<br>100<br>80<br>60<br>40<br>90<br>70<br>50<br>30<br>20<br>10<br>0<br>Output Load [%]<br>Input Voltage [VAC]<br>85<br>90<br>264||||| **==> picture [526 x 503] intentionally omitted <==** **----- Start of picture text -----**<br> Derating Graph Line Derating<br>(@ Chamber and natural convection 0.1m/s)<br>100 100<br>90 90<br>80 80<br>70 70<br>60 60<br>50 50<br>40 40<br>30 30<br>20 20<br>10 10<br>0 0<br>-25 -10 5 20 35 50 65 80 95 85 90 264<br>70<br>Ambient Temperature [°C] Input Voltage [VAC]<br>Notes:<br> Note10: Recognized by UL for safe operation up to 4000m. High altitude operation may impact the performance and lifetime.<br> Contact TechsupportAT@recom-power.com for advice<br> Note11: Based on calculation for 5Vout<br>SAFETY AND CERTIFICATIONS<br>Certificate Type (Safety) Report / File Number Standard<br>IEC60950-1:2005 2nd Edition + Am2:2013<br>Information Technology Equipment, General Requirements for Safety SA1804152L01001<br>EN60950-1:2006 + A12:2011 + A2:2013<br>Audio/Video, information and communication technology equipment - E196683-A5 and UL62368-1, 2nd Edition<br>Part1: Safety requirements E19668-A6001 CAN/CSA-C22.2 No. 62368-1-14<br>Audio/Video, information and communication technology equipment -<br>IEC62368-1:2014 2nd Edition<br>Part1: Safety requirements (CB Scheme)<br>SA1804152S 001<br>Audio/Video, information and communication technology equipment -<br>EN62368-1:2014+A11:2017<br>Part1: Safety requirements<br>Household and similar electrical appliances – Safety – Part 1: Gener-<br>SES180313004001E EN60335-1:2012+A11:2014<br>al requirements<br>RoHS2 RoHS 2011/65/EU + AM2015/863<br>continued on next page<br>Output Load [%] Output Load [%]<br>**----- End of picture text -----**<br> REV.: 6/2023 PA-4 **www.recom-power.com** ## **RAC01-GA** ## **AC/DC Converter** ## **Series** Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) |EMC Compliance|EMC Compliance|EMC Compliance|EMC Compliance|Condition|Condition|Condition|Standard / Criterion| |---|---|---|---|---|---|---|---| |Electromagnetic compatibility of multimedia equipment - Emission<br>requirements||||EA1804152E 01001|||EN55032, Class A| |Information technology equipment - Immunity characteristics - Limits<br>and methods of measurement|||||||EN55024:2010 + A1:2015| |ESD Electrostatic discharge immunity test||||Air ±2, 4, 8kV<br>Contact ±2, 4kV|||EN61000-4-2:2009, Criteria A| |Radiated, radio-frequency, electromagnetic feld immunity test||||3V/m|||EN61000-4-3:2006 + A2:2010, Criteria A| |Fast Transient and Burst Immunity||||AC Power Port: ±1.0kV|||EN61000-4-4:2012, Criteria A| |Surge Immunity||||AC Power Port: L-N ±1.0kV|||EN61000-4-5:2014, Criteria B| |Immunity to conducted disturbances, induced by radio-frequency felds||||AC Power Port 3V|||EN61000-4-6:2014, Criteria A| |Power Magnetic Field Immunity||||50Hz, 1A/m|||EN61000-4-8:2009, Criteria A| |Voltage Dips and Interruption||||Voltage Dips >95%|||EN61000-4-11:2004, Criteria A| |||||Voltage Dips 30%|||EN61000-4-11:2004, Criteria B| |||||Voltage Interruptions >95%|||EN61000-4-11:2004, Criteria B| |Limits of Voltage Fluctuations & Flicker|||||||EN61000-3-3:2013| |L<br>N<br>CY1<br>CY2<br>CY1,CY2<br>Vishay 564R30TSD22, SLCC<br>X7R radial, 2.2nF, 3kVDC ±10%<br>EMI Filtering according to EN60335-1 / EN55032 Class B Compliance||||Compliance|||+VOUT<br>-VOUT| ||||||||| ||||||||| ||||||||| ||||||CY2||| ||||||||| ||||||CY1,CY2||| ||||Vishay 564R30TSD22, SLCC<br>X7R radial, 2.2nF, 3kVDC ±10%||||| |DIMENSION AND PHYSICAL CHARACTERISTICS|DIMENSION AND PHYSICAL CHARACTERISTICS|DIMENSION AND PHYSICAL CHARACTERISTICS| |---|---|---| |Parameter|Type|Value| |Material|case<br>PCB|black plastic (UL94V-2)<br>FR4(UL94V-0)| |Dimension(LxWxH)||33.7 x 22.2 x 19.0mm| |Weight||12gtyp.| |continued on next page||| REV.: 6/2023 PA-5 **www.recom-power.com** ## **RAC01-GA** ## **AC/DC Converter** ## **Series** Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) **==> picture [488 x 398] intentionally omitted <==** **----- Start of picture text -----**<br> Dimension Drawing (mm)<br>33.7<br>embossed logo<br>Pin Connections<br> Pin # Single<br>2.85 15.24<br>1 VAC in (L)<br> 2 VAC in (N)<br>Recommended Footprint Details<br> 3 -Vout<br>2.54<br>Ø0.8 [±0.03] 4 +Vout<br>Tolerance:<br>Pin length: -0.5/+0.9<br>1 2 3 xx.x= ±0.5mm<br>x.xx= ±0.25mm<br>Bottom View 4 Top View 4<br>2 3 1<br>28.00<br>22.2<br>19.0<br>3.7<br>2.54<br>7.62<br>**----- End of picture text -----**<br> |||| |---|---|---| |PACKAGING INFORMATION||| |Parameter|Type|Value| |PackagingDimension(LxWxH)|tube|470.0 x 36.4 x 26.4mm| |Packaging Quantity||20pcs| |Storage Temperature Range||-25°C to +85°C| |Storage Humidity|non-condensing|5% - 95% RH max.| The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. REV.: 6/2023 PA-6 **www.recom-power.com**
Updated at June 3, 2026
RECOM Power is a globally recognized manufacturer specializing in standard and customized power conversion solutions. Headquartered in Austria with state-of-the-art research and development facilities, the company has built a strong reputation for innovation and reliability. Operating from ISO 9001 and IATF 16949 certified manufacturing sites, RECOM delivers premium power supplies engineered for demanding applications across IoT, Industry 4.0, medical technology, and transportation. The core of our RECOM Power portfolio is dedicated to advanced power and line protection, featuring an extensive selection of high-performance AC/DC converters. These modules are designed to provide efficient, stable power distribution for a wide array of industrial and commercial electronics. In addition to general-purpose power supplies, we offer a robust range of AC/DC LED power supplies specifically optimized to meet the stringent efficiency and lifespan requirements of modern lighting systems. To support comprehensive power architecture design, our selection also includes highly efficient DC/DC converters ideal for precise voltage regulation in complex circuits. Furthermore, we provide specialized passive components such as RECOM power inductors, ensuring engineers have access to the critical, high-quality components required to develop resilient and optimized power delivery systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →