- Manufacturer: BANNER ENGINEERING
- Product type: Signal Converters
- SVHC: No SVHC (15-Jan-2018)
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 280.11 € |
| Current stock | 10+ |
| Lead time | 30 days |
R90C 4-Port Modbus[®] to Analog Hub ## Quick Start Guide This guide is designed to help you set up and install the R90C 4-Port ModBus to Analog Hub. For complete information on programming, performance, troubleshooting, dimensions, and accessories, please refer to the Instruction Manual at www.bannerengineering.com. Search for p/n 227463 to view the Instruction Manual. Use of this document assumes familiarity with pertinent industry standards and practices. **==> picture [119 x 52] intentionally omitted <==** - Compact ModBus[®] to analog converter that generates a current or voltage output on each of the four ports - Rugged over-molded design meets IP65, IP67, and IP68 - Connects directly to a sensor or anywhere in-line for ease of use - R90C ModBus hubs are a quick, easy, and economical way to integrate analog outputs into a ModBus system ## Overview The R90C 4-Port ModBus to Analog Hub can output either 0 V to 10 V, or 4 mA to 20mA, to each of the four unique ports. Writing to the appropriate ModBus RTU register allows the user to select the type of output - voltage or current - for each port. ## Mechanical Installation Install the R90C 4-Port ModBus to Analog Hub to allow access for functional checks, maintenance, and service or replacement. All mounting hardware is supplied by the user. Fasteners must be of sufficient strength to guard against breakage. Use of permanent fasteners or locking hardware is recommended to prevent the loosening or displacement of the device. The mounting hole (4.5 mm) in the R90C 4-Port ModBus to Analog Hub accepts M4 (#8) hardware. See the figure below to help in determining the minimum screw length. **==> picture [244 x 121] intentionally omitted <==** **----- Start of picture text -----**<br> 16.0 mm<br>X<br>3 mm *<br>NUT<br> * for minimum<br>Screw Length = 16.0 mm + “X” mm + 3 mm engagement of<br>three threads<br>**----- End of picture text -----**<br> CAUTION: Do not overtighten the R90C 4-Port ModBus to Analog Hub's mounting screw during installation. Overtightening can affect the performance of the R90C 4-Port ModBus to Analog Hub. ## Status Indicators The R90C 4-Port ModBus to Analog Hub has matching amber LED indicators on both sides for each analog output port to allow for installation needs and still provide adequate indication visibility. |Analog Output Amber LEDs|Analog Output Amber LEDs|Power and Communication Green LED|Power and Communication Green LED| |---|---|---|---| |Indication|Status|Indication|Status| |Off|Turns off if the actual analog out value is outside the<br>defned output range|Off|Power off| |||Solid Green|Power on| |Solid Amber|Turns on if the actual analog out value is within the<br>defned output range||| |||Flashing Green, 4 Hz|ModBus Communications are active| ||||| Original Document 227462 Rev. A 15 December 2022 227462 R90C 4-Port Modbus[®] to Analog Hub ## Specifications Supply Voltage 24 V DC (± 10%) at 125 mA maximum Power Pass-Through Current 4 A maximum total across all four ports Load Requirements Voltage Mode = Resistance > 1000 ohms Current Mode = Resistance < 500 ohms Supply Protection Circuitry Protected against reverse polarity and transient voltages Leakage Current Immunity 400 µA Indicators Green: Power, ModBus communication Amber: Analog output status ## Connections (4) Integral 4-pin M12 female quick-disconnect connector (1) Integral 5-pin M12 male quick-disconnect connector Construction Coupling Material: Nickel-plated brass Connector Body: PVC translucent black Vibration and Mechanical Shock Meets IEC 60068-2-6 requirements (Vibration: 10 Hz to 55 Hz, 0.5 mm amplitude, 5 minutes sweep, 30 minutes dwell) Meets IEC 60068-2-27 requirements (Shock: 15G 11 ms duration, half sine wave) Certifcations Banner Engineering BV Park Lane, Culliganlaan 2F bus 3, 1831 Diegem, BELGIUM **==> picture [32 x 56] intentionally omitted <==** Turck Banner LTD Blenheim House, Blenheim Court, Wickford, Essex SS11 8YT, Great Britain Environmental Rating IP65, IP67, IP68 NEMA/UL Type 1 Operating Conditions Temperature: –40 °C to +70 °C (–40 °F to +158 °F) - 90% at +70 °C maximum relative humidity (non-condensing) Storage Temperature: –40 °C to +80 °C (–40 °F to +176 °F) Required Overcurrent Protection WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations. Overcurrent protection is required to be provided by end product application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply. Supply wiring leads < 24 AWG shall not be spliced. For additional product support, go to www.bannerengineering.com. |Supply Wiring (AWG)|Required Overcurrent Protection (Amps)| |---|---| |20|5.0| |22|3.0| |24|2.0| |26|1.0| |28|0.8| |30|0.5| ## Banner Engineering Corp. Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com. For patent information, see www.bannerengineering.com/patents. ## FCC Part 15 Class B This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. ## Industry Canada This device complies with CAN ICES-3 (B)/NMB-3(B). Operation is subject to the following two conditions: 1) This device may not cause harmful interference; and 2) This device must accept any interference received, including interference that may cause undesired operation. Cet appareil est conforme à la norme NMB-3(B). Le fonctionnement est soumis aux deux conditions suivantes : (1) ce dispositif ne peut pas occasionner d'interférences, et (2) il doit tolérer toute interférence, y compris celles susceptibles de provoquer un fonctionnement non souhaité du dispositif. © Banner Engineering Corp. All rights reserved
Updated at April 23, 2026
Founded in 1966, Banner Engineering is a globally recognized leader in the design and manufacture of industrial automation products. The company is renowned for developing innovative, high-quality solutions that improve operational efficiency, safeguard personnel, and optimize manufacturing processes across a diverse range of industries. Our extensive selection of Banner Engineering components prominently features their industry-leading sensing technologies. We offer a comprehensive array of precision light sensors engineered for accurate detection and measurement in demanding environments. Complementing this core sensing portfolio is a robust offering of automation signaling devices, including visual signal indicator units and essential accessories, which provide clear and immediate communication of machine status. Beyond primary sensing and indication solutions, our range encompasses critical components for broader process control and machine safety. This includes advanced process controllers, reliable pressure sensors and transducers, and dependable safety relays. Supported by a variety of purpose-built sensor accessories and fiber optic lead assemblies, Banner Engineering delivers the durable, high-performance technologies required to build and maintain sophisticated automated systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.