R45C-K-UUQ
Signal Converter, Voltage, Voltage, 1 Channels, 0.5 %, 30 VDC
- Manufacturer: BANNER ENGINEERING
- Product type: Signal Converters
- SVHC: No SVHC (15-Jan-2018)
- Accuracy %: 0.5%
- Product Range: R45C Series
- Supply Voltage: 30VDC
- Isolation Input: -
- No. of Channels: 1 Channel
- Output Accuracy: -
- No. of Output Channels: 1Channels
- Signal Conditioner Input: Voltage
- Signal Conditioner Output: Voltage
- Signal Conditioner Mounting: -
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 121.57 € |
| Current stock | 10+ |
| Lead time | 30 days |
R45C IO-Link Device to Analog In-Out Converter Instruction Manual ## Features - Compact analog to IO-Link device converter that outputs an analog value, voltage or current, as presented by the IO-Link Master - The converter also connects to an analog source, voltage or current, and outputs the value to the IO-Link master - Rugged overmolded design meets IP65, IP67, and IP68 - • Connects directly to a sensor or anywhere in-line for ease of use ## Models **==> picture [480 x 66] intentionally omitted <==** **----- Start of picture text -----**<br> Housing Function Male Female Connector<br>R45 C - K - II Q<br>C = Converter K = IO-Link II = Analog Current In/Current Out Q = Integral M12 quick disconnect<br>UU = Analog Voltage In/Voltage Out<br>**----- End of picture text -----**<br> ## Overview ## Analog In When an analog input value is received by this converter, the numerical representational value is sent to an IO-Link Master via Process Data In (PDI). PDI Analog Ranges: - Voltage = 0 mV to 10,000 mV - Current = 4,000 µA to 20,000 µA ## Analog Out This converter also allows for the user to output an analog value by sending the numerical analog value from the IO-Link Master via Process Data Out (PDO). PDO Analog Ranges: - Voltage = 0 mV to 11,000 mV - Current = 0 µA to 24,000 µA ## PDO Outside Valid Range (POVR) If the PDO value sent to this converter is outside of the PDO Analog Range value, then the actual analog output value will be set to the one of the three selectable POVR levels after a 2 second delay: - Low (default): 0 V or 3.5 mA - High: 10.5 V or 20.5 mA - Hold: Level retains previous value indefinitely NOTE: If a connected IO-Link sensor is changed back to SIO mode, then the previous value will be held. ## Status Indicators The R45C IO-Link Device to Analog In-Out Converter has three amber LED indicators on both sides for IO-Link and analog communications to allow for installation needs and still provide adequate indication visibility. There is also a green LED indicator on both sides of the converter, which signals the device's power status. Original Instructions September 11, 2023 © Banner Engineering Corp. p/n: 223053 Rev. B 223053 R45C IO-Link Device to Analog In-Out Converter Instruction Manual **==> picture [141 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> R45C status indicators – front and back<br>**----- End of picture text -----**<br> **IO-Link LED** (on either side)* **Power LED** (on either side)* **Analog 1 In/Out LEDs** (on either side)* **==> picture [75 x 71] intentionally omitted <==** **==> picture [79 x 12] intentionally omitted <==** **----- Start of picture text -----**<br> Rotate 180˚<br>**----- End of picture text -----**<br> **==> picture [75 x 71] intentionally omitted <==** **Analog 2 In/Out LEDs** (on either side)* * Indicator LEDs are visible through translucent housing **==> picture [500 x 233] intentionally omitted <==** **----- Start of picture text -----**<br> IO-Link Amber LED<br>Indication Status<br>Off IO-Link communications are not present<br>Flashing Amber (900 ms On, 100 ms Off) IO-Link communications are active<br>Analog In Amber LED<br>Indication Status<br>Off Analog current value is less than setpoint SP1 OR analog value is greater than setpoint SP2<br>Solid Amber Analog current value is between setpoint SP1 AND setpoint SP2<br>Default Current Values: Default Voltage Values:<br>• SP1 = 0.004 A • SP1 = 0 V<br>• SP2 = 0.02 A • SP2 = 10 V<br>Analog Out Amber LED<br>Indication Status<br>Off Turns off if written PDO analog value is outside the allowable output range<br>Solid Amber Turns on if written PDO analog value is inside the allowable output range<br>Allowable Current Range: 0 mA to 24 mA<br>Allowable Voltage Range: 0 V to 11 V<br>**----- End of picture text -----**<br> ## Installation Instructions ## Mechanical Installation Install the R45C to allow access for functional checks, maintenance, and service or replacement. Do not install the R45C in such a way to allow for intentional defeat. Fasteners must be of sufficient strength to guard against breakage. The use of permanent fasteners or locking hardware is recommended to prevent the loosening or displacement of the device. The mounting hole (4.5 mm) in the R45C accepts M4 (#8) hardware. See the figure below to help in determining the minimum screw length. September 11, 2023 page 2 © Banner Engineering Corp. All rights reserved. R45C IO-Link Device to Analog In-Out Converter Instruction Manual **==> picture [96 x 83] intentionally omitted <==** **----- Start of picture text -----**<br> 3.9 mm<br>12.9 mm<br>X<br>3 mm * * for minimum<br>engagement of<br>three threads<br>**----- End of picture text -----**<br> Screw Length (with screw head fitting in counterbore) = 12.9 mm + “X” mm + 3 mm **==> picture [32 x 38] intentionally omitted <==** CAUTION: Do not overtighten the R45C's mounting screw during installation. Overtightening can affect the performance of the R45C. ## Wiring Diagrams **==> picture [500 x 262] intentionally omitted <==** **----- Start of picture text -----**<br> Male Female Pin Wire Color<br>1 1 Brown<br>2 2 White<br>2<br>1 3 Blue<br>4<br>3<br>3 4 4 Black<br>Female (Analog In-Out) Signal Description<br>Pin 1 18 V DC to 30 V DC<br>Pin 2 Analog In<br>Pin 3 Ground<br>Pin 4 Analog Out<br>Male (IO-Link Master) Signal Description<br>Pin 1 18 V DC to 30 V DC<br>Pin 2 Banner-specific<br>Pin 3 Ground<br>Pin 4 IO-Link<br>**----- End of picture text -----**<br> ## Configuration The measured current value is available via Process Data as the measure value μA, and the voltage is available in mV. For more information, see Banner P/N 223174 R45C Analog Converter (Voltage and Current) IO-Link Data Reference Guide and Banner P/N 223171 R45C-K-Analog IO-LINK IODD Files. ## IO-Link® IO-Link® is a point-to-point communication link between a master device and a sensor and/or light. It can be used to automatically parameterize sensors or lights and to transmit process data. For the latest IO-Link protocol and specifications, please visit www.io-link.com. For the latest IODD files, please refer to the Banner Engineering Corp website at: www.bannerengineering.com. ## Specifications Supply Voltage Supply Protection Circuitry 18 V DC to 30 V DC at 50 mA maximum Protected against reverse polarity and transient voltages Power Pass-Through Current Leakage Current Immunity 4 A maximum 400 µA September 11, 2023 page 3 © Banner Engineering Corp. All rights reserved. R45C IO-Link Device to Analog In-Out Converter Instruction Manual ## Resolution 14 bits Accuracy 0.5% ## Indicators Green: Power Amber: IO-Link communications Amber: Analog input value present Amber: Analog output value in range Connections Integral male/female 4-pin M12 quick disconnect Construction Coupling Material: Nickel-plated brass Connector Body: PVC translucent black ## Vibration and Mechanical Shock Meets IEC 60068-2-6 requirements (Vibration: 10 Hz to 55 Hz, 0.5 mm amplitude, 5 minutes sweep, 30 minutes dwell) Meets IEC 60068-2-27 requirements (Shock: 15G 11 ms duration, half sine wave) Certifications Banner Engineering BV Park Lane, Culliganlaan 2F bus 3 1831 Diegem, BELGIUM Environmental Rating IP65, IP67, IP68 NEMA/UL Type 1 ## Operating Conditions Temperature: –40 °C to +70 °C (–40 °F to +158 °F) 90% at +70 °C maximum relative humidity (non-condensing) Storage Temperature: –40 °C to +80 °C (–40 °F to +176 °F) Required Overcurrent Protection **==> picture [32 x 42] intentionally omitted <==** WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations. Overcurrent protection is required to be provided by end product application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply. Supply wiring leads < 24 AWG shall not be spliced. For additional product support, go to www.bannerengineering.com. **==> picture [222 x 79] intentionally omitted <==** **----- Start of picture text -----**<br> Supply Supply<br>Required Overcurrent Required Overcurrent<br>Wiring Wiring<br>Protection (A) Protection (A)<br>(AWG) (AWG)<br>20 5.0 26 1.0<br>22 3.0 28 0.8<br>24 1.0 30 0.5<br>**----- End of picture text -----**<br> ## FCC Part 15 Class B This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. ## Industry Canada ICES-003(B) This device complies with CAN ICES-3 (B)/NMB-3(B). Operation is subject to the following two conditions: 1) This device may not cause harmful interference; and 2) This device must accept any interference received, including interference that may cause undesired operation. Cet appareil est conforme à la norme NMB-3(B). Le fonctionnement est soumis aux deux conditions suivantes : (1) ce dispositif ne peut pas occasionner d'interférences, et (2) il doit tolérer toute interférence, y compris celles susceptibles de provoquer un fonctionnement non souhaité du dispositif. ## Dimensions All measurements are listed in millimeters [inches], unless noted otherwise. September 11, 2023 page 4 © Banner Engineering Corp. All rights reserved. R45C IO-Link Device to Analog In-Out Converter Instruction Manual ## Accessories ## Cordsets **==> picture [500 x 197] intentionally omitted <==** **----- Start of picture text -----**<br> 4-Pin Threaded M12 Cordsets—Double Ended<br>Model Length Style Dimensions Pinout<br>MQDEC-401SS 0.31 m (1 ft) Female<br>MQDEC-403SS 0.91 m (2.99 ft)<br>2<br>40 Typ.<br>MQDEC-406SS 1.83 m (6 ft) [1.58"] 1<br>MQDEC-412SS 3.66 m (12 ft) 4 3<br>MQDEC-420SS 6.10 m (20 ft) M12 x 1<br>MQDEC-430SS 9.14 m (30.2 ft) Male Straight/Female ø 14.5 [0.57"] Male<br>Straight 44 Typ.<br>[1.73"] 1<br>2<br>4<br>MQDEC-450SS 15.2 m (49.9 ft) M12 x 1 3<br>ø 14.5 [0.57"] 1 = Brown<br>2 = White<br>3 = Blue<br>4 = Black<br>**----- End of picture text -----**<br> ## Banner Engineering Corp Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com. For patent information, see www.bannerengineering.com/patents. September 11, 2023 page 5 © Banner Engineering Corp. All rights reserved.
Updated at April 23, 2026
Founded in 1966, Banner Engineering is a globally recognized leader in the design and manufacture of industrial automation products. The company is renowned for developing innovative, high-quality solutions that improve operational efficiency, safeguard personnel, and optimize manufacturing processes across a diverse range of industries. Our extensive selection of Banner Engineering components prominently features their industry-leading sensing technologies. We offer a comprehensive array of precision light sensors engineered for accurate detection and measurement in demanding environments. Complementing this core sensing portfolio is a robust offering of automation signaling devices, including visual signal indicator units and essential accessories, which provide clear and immediate communication of machine status. Beyond primary sensing and indication solutions, our range encompasses critical components for broader process control and machine safety. This includes advanced process controllers, reliable pressure sensors and transducers, and dependable safety relays. Supported by a variety of purpose-built sensor accessories and fiber optic lead assemblies, Banner Engineering delivers the durable, high-performance technologies required to build and maintain sophisticated automated systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →