Image not available
Illustrative purposes only
R-3W
POWER WARNING ALERT, 40-750VAC
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: GRACE TECHNOLOGIES
- Product type: Visual Signal Indicator Units
- Module Lens Colour:-; Supply Voltage VAC:600V; Supply Voltage VDC:1kV; Visual Signal Type:Flashing; Lens Diameter:39.34mm; Product Range:-; IP / NEMA Rating:NEMA 4; Pow 44P9342
- SVHC: No SVHC (04-Feb-2026)
- Power Rating: 1.2W
- Lens Diameter: 39.34mm
- External Height: 78mm
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 227.3 € |
| Current stock | 10+ |
| Lead time | 30 days |
Permanent Electrical Safety Devices **Thru-Door Voltage Indicator Flashing and Non-Flashing Catalog Numbers Product Data Sheet** ~~a~~ **R-3W / R-3W-SR** SafeSide® thru-door voltage indicators provide electrical **Voltage Indicator** safety information while the panel doors are safely closed. **with Solid-on LEDs or Flashing LEDs** This “one-size-fits-all” solution detects 3-phase AC or DC ~~7~~ **FEATURES:** voltage from 40-750VAC/30-1000VDC. The encapsulated Redundant Circuitry / Long Life LED's construction and redundant circuit design means rugged 40-750VAC / 30-1000VDC / 35-600VAC 1Ø reliability. SafeSide® products are available with flashing Potted Construction with 6' Leads LEDs (R-3W) and non-flashing LEDs (R-3W-SR). Phase Insensitive Redundant Circuitry / Long Life LED's 40-750VAC / 30-1000VDC / 35-600VAC 1Ø Potted Construction with 6' Leads Phase Insensitive 30mm Pushbutton or Pilot Hole High Surge Immunity **UL TYPE 4X** UL Listed, Type 4X, 12, 13 **C LISTED** ® **L US** IND. CONT. EQ. . A 6 496Y **APPLICATIONS:** UL File: E256847 Circuit Breaker Disconnects - No Visible Blades **RoHS** ~~Do~~ High Energy Panels (NFPA 70E Category 3 or 4 ce AAA Frequently Accessed Panels Mechanical LOTO: Indicating Zero Energy Panels with Multiple Power Sources **Safer Lock-Out Tag-Out (LOTO)** CC Keeping personnel away from live voltage is foundational to electrical safety. Electrical safety demands a precise answer to the question 'Is voltage present?'. Thru-door voltage indicators provide visibility of voltage from outside the enclosure without exposing personnel to voltage. ## **More Productivity in Mechanical LOTO** Workers performing mechanical LOTO must isolate electrical energy. An externally-mounted voltage detector provides a means to check voltage inside an electrical panel. Without a voltage indicator, a mechanic performing mechanical LOTO would be required to work in tandem with an electrician using a voltmeter to physically verify voltage inside an electrical panel. In this case, the electrician is exposed to voltage. With thru-door voltage detectors, the mechanic can verify zero electrical energy without any exposure to voltage. Three Phase 40-750VAC/30-1000VDC UL-Listed Voltage Indicator for Type 4X/12/13 for 30mm Mounting |**R-3W**|Flashing| |---|---| |**R-3W-KB**<br>**1**<br>**R-3W-L**<br>**R-3W-KB-L**|Flush Mount Assembly with Bezel and R-3W (UL)<br>Adhesive-Backed Warning Label<br>(slips over installed R-3W)<br>Adhesive-Backed Warning Label<br>(slips over installed R-3W-KB)| ||| |**R-3W-SR**<br>**2**<br>**R-3W-SR-KB**<br>**1**|Non-Flashing<br>Flush Mount Assembly with Bezel and R-3W-SR (UL)| |**R-3W-SR-L**|Adhesive-Backed Warning Label<br>(slips over installed R-3W-SR)| |**R-3W-KB-L**|Adhesive-Backed Warning Label<br>(slips over installed R-3W-SR-KB)| ||| |**R-3W2**<br>**3**<br>**R-3W2-KB**<br>**1**|Hazardous Location Flashing Voltage Indicator (Suitable for<br>use in Class 1, Division 2 (Zone 2), Groups A, B, C, D hazardous<br>Location, or Non-Hazardous Locations Only)<br>Flush Mount Assembly with Bezel and R-3W2 (UL)| |**R-3W-L**|Adhesive-Backed Warning Label<br>(slips over installed R-3W2)| |**R-3W-KB-L**|Adhesive-Backed Warning Label<br>(slips over installed R-3W2-KB)| ## **Reduced Voltage Exposure and Arc Flash Risk** Voltage is the common denominator in an electrical accident or an arc flash; no voltage means no accident, no arc flash. While performing electrical LOTO with a thru-door voltage detector installed, the electrician can pre-check the internal voltage state without opening the enclosure. Next, the electrician should replicate a zero voltage reading with his voltmeter as per NFPA 70e 120.1(5). This low-cost, redundant voltage-verification task reduces arc flash risk and increases electrical safety for workers. **Warning:** Verify an electrical conductor has been de-energized using an adequately rated voltage detector before working on it. Follow appropriate Energy Control (Lockout/Tagout) procedures as per OSHA Subpart S; the current edition of NFPA 70E; and the current edition of CSA Z462. - **(1)** Must be purchased as an assembly for UL Listing **(2)** For the R-3W-SR, the LED appearance for differing voltages as follows: 32-159V(FLASH); 160-329V(SHIMMER); 330V+(SOLID)). **(3)** See R-3W2 datasheet for specifications and UL information **5001 Tremont Avenue** © 2014 Grace Engineered Products, Inc. Data:R-3W/R-3W-SR:08/2014 **Davenport, IA 52807** LIT-DS-R3W **(800) 280-9517 Fax: (563) 386-9639** SafeSide® is a Trademark of Grace Engineered Products, Inc. _**www.pesd.com**_ ## **Voltage Indicator** ## **TYPICAL CONFIGURATION*:** **==> picture [703 x 181] intentionally omitted <==** **----- Start of picture text -----**<br> VAC VDC [ 31.200.5mm+ 0.02+ 0.5mm] OPERATIONAL RANGE: AC Single or 3-Phase: 40-750V 50/60Hz<br>THREE PHASE DELTA, 3W + GNDMAIN FUSED L1 -- L2L1POWER++ DANGER ++GNDL3 -- 1.549 DIA.[39.34mm] 1.102 -0+.012[28.00mm -0+.03] KNOCKOUTPANEL UP TO 1ANTI-ROTATIONLOCATIONS DC OR STORED ENERGY:MAXIMUM VOLTAGE: secondsOperates up to 400 Hz30 to 1000 VDC750VAC/1000VDC - Surge 4300V for 5<br>se FEED SAFETYSWITCH — L2 eZ CUSTOMER PANEL Se) 1.381 DIA. SLEEVE | 30mm HEX NUT a l l 0.157[4.00mm] — POWER CONSUMPTION: re TEMPERATURES: 1.2 Watts @ 750 VAC (Approximately)Operate: -20ºC to +55ºC, Storage: -45ºC to<br>ORBREAKER O-RING SEAL M30X1.5 4G6G EXT +85ºC<br>‘a L3 J } \\ Wire: 18 AWG,Style 1452, FAILURE CURRENT: — is 3.7mA @ 750 3Maximum single component failure fault current-Phase<br>FUSING: Follow all Local, State, and national Electrical<br>GROUND Codes when installing this equipment.<br>ORISOLATED H T REDYELBLU 1.050 eb [31.75mm]1.250 Overcurrent protection of the supply leads maybe necessary. The installation of overcurrent<br>GRN [26.67mm] protection shall be in accordance with the<br>0 os EAa ; a requirements in the NEC (NFPA 70) or end<br>3.071<br>[78.00mm] product standard(s) when used in the final<br>installation.<br>**----- End of picture text -----**<br> ## **INDICATOR FLASH RATES for the R-3W only (L1,L2,L3,GND)** ## **Accessories:** |~~3-PHASE LINE-TO-LINE~~|~~**<29**~~|~~**30**~~|~~**120**~~|~~**240**~~|~~**480**~~|~~**600**~~|~~**750**~~| |---|---|---|---|---|---|---|---| |~~3-PHASE LINE-TO-LINE~~|~~**<29**~~|~~**30**~~|~~**120**~~|~~**240**~~|~~**480**~~|~~**600**~~|~~**750**~~| |FLASHES/SEC(TYPICAL)|**0**|**1.3**|**4.2**|**5.8**|**7.3**|**8**|**8.8**| |DC OR STORED ENERGY(VDC)|**<27**|**30**|**48**|**110**|**300**|**600**|**1000**| |FLASHES/SEC(TYPICAL)|**0**|**1.6**|**2.5**|**4.5**|**6.9**|**8.8**|**9.1**| **==> picture [38 x 10] intentionally omitted <==** **----- Start of picture text -----**<br> NEW!<br>**----- End of picture text -----**<br> Dimensions of the Bezel - Diameter: 2.25” Outside cabinet depth: .20” Inside cabinet depth: 3.50” **New! Bezel-mount Installation for Voltage Indicator!** Create a near-flush look by purchasing your Voltage Indicator with our new bezel. **Part Number Description** ~~———— ——~~ **R-3W-KB Flashing Voltage Indicator with Bezel R-3W-SR-KB Non-Flashing Voltage Indicator with Bezel R-3W2-KB Class 1 Div 2 Voltage Indicator with Bezel** *Corresponding label available for bezel-mount configurations. Note: When mounting the Bezel (part numbers with -KB), the diameter of the cut-out is as follows: 1.701 inches (43.21mm). **==> picture [13 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> 2.0”<br>**----- End of picture text -----**<br> ## **Part #: R-3W-NPT125** A 30mm to 1 ” NPT conduit adapter. This assembly fits into a standard conduit LB for mounting on the outside of an enclosure. **==> picture [16 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> 4.5”<br>**----- End of picture text -----**<br> ## **Voltage Indicator Alert Label** **DANGER VOLTAGE IF FLASHING SAFETY PROCEDURES STILL APPLY.TEST BEFORE TOUCHING.** This adhesive-back label fits over an installed power warning alert. Warning language differs for flashing and non-flashing units. **Part Number Description** GRACEE N G I N E E R E DPRODUCTS, INCWWW.GRACE-ENG.COM **Read instructionsWARNING! R-3W-L Label for Flashing and Class 1 Div 2 Voltage Indicator before installing R-3W-SR-L Label for Non-Flashing Voltage Indicator** Label dimensions are 3"W x 2.3"H. **R-3W-KB-L Label for all Bezel Units** ) 7 ~~a~~ ## **Part #: R-3W-DR-C6** Use this door mount accessory for additional voltage protection. Includes a 30mm adapter and 6' of NW10 flexible conduit. (Allow 4.5" depth into panel).
Updated at April 23, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →