PX3AG1BH025BSAAX
Pressure Sensor, Heavy Duty, 25 bar, Ratiometric, Sealed Gauge, 5 VDC, G1/4, 3.5 mA
- Manufacturer: HONEYWELL
- Product type: Pressure Transducers
- Port Style: G1/4
- Product Range: PX3 Series
- Sensor Output: Ratiometric
- Supply Current: 3.5mA
- Voltage Rating: 5VDC
- Operating Pressure Max: 25bar
- Pressure Measurement Type: Sealed Gauge
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 62.87 € |
| Current stock | 25+ |
| Lead time | 7 days |
## Heavy Duty Pressure Transducers ## **PX2 Series** 1 bar to 70 bar | 100 kPa to 7 MPa | 15 psi to 1000 psi Datasheet ## Heavy Duty Pressure Transducers Honeywell’s PX2 Series Heavy Duty Pressure Transducer is a portfolio of highly configurable pressure sensors that use piezoresistive sensing technology with ASIC (Application Specific Integrated Circuit) signal conditioning in a stainless steel housing. The PX2 Series is fully calibrated and compensated for offset, sensitivity, temperature effects and non-linearity using the on-board ASIC. This provides a Total Error Band of ±2% over the operating temperature range of -40 ºC to 125 ºC [-40 °F to 257 °F]. With thousands of possible configurations, the PX2 Series allows Honeywell to meet customer requirements and quickly provide samples. New standard configurations are regularly being added. The PX2 Series is compatible with a variety of harsh media including brake fluid, common hydrofluorocarbon refrigerants, engine oil, tap water, hydraulic fluids, and compressed air. The wide operating temperature range, ingress protection up to IP69K, and 100 V/m radiated immunity allow for reliable performance in tough environments. These transducers measure absolute, sealed gage, or vented gage pressure. The absolute versions have an internal vacuum reference and an output value proportional to absolute pressure, the sealed gage versions have an internal pressure reference of one atmosphere at sea level, and the vented gage versions measure pressure with respect to ambient pressure. The PX2 Series is available in three pressure ranges: - 1 bar to 70 bar - 100 kPa to 7 MPa - 15 psi to 1000 psi All products are RoHS compliant and are designed and manufactured according to ISO 9001 standards. ## _**What makes our transducers better?**_ - **Affordable:** Competitive product cost, over 60,000 standard configurations, and global application support - ° **Available:** Wide selection of features and a short lead time for samples and production parts - **High performance:** Small Total Error Band, fast response time, and longer life - 0 ¢ | **High durability:** Environmentally tough, wide operating temperature - ° range, and ability to withstand f . mechanical shock and vibration ## _**Count on affordability and availability with these high performing, durable transducers.**_ AFFORDABLE • AvAiLABLE • high pERFORmAncE **2** sensing.honeywell.com Features and Benefits ## _**Affordability minimizes your cost to produce.**_ ## **COST EFFECTIVE*** The PX2 Series is a precise pressure measurement solution that optimizes system performance at a competitive cost. ## **DESIGNED FOR CONFIGURABILITY*** With over 60,000 standard configurations, the PX2 Series easily meets our customers’ specific application needs. ## **APPLICATION EXPERTISE*** Knowledgeable application engineers are available to answer customers’ specific design questions during the development of their product. ## **GLOBAL SUPPORT** Honeywell’s global presence offers customers immediate product and application support throughout the development cycle, from design to global manufacturing. ## _**Available feature-rich and fast.**_ aLCLTFSCSCt‘“‘CC*S ## **WIDE SELECTION OF OPTIONS** Numerous standard or custom connectors, ports, pressure ranges and types, and output options include: - Electrical connector types: Delphi Metri-Pack 150 (UL 94 HB or V-0 options), - Micro M12, DIN, Deutsch, or cable harness (1 m, 2 m, 3 m, or 5 m). - Pressure port types: 7/16-20 UNF 1/4 in 45° Flare Female Schrader (SAE J512), 7/16-20 UNF 45° Flare Male (SAE J513), 7/16-20 UNF 37° Flare Male (SAE J514), G1/4 (ISO 1179-3), G1/8 (ISO 1179-3), M12 x 1.5 (ISO 6149-3), - 1/4-18 NPT, 1/8-27 NPT, 9/16-18 UNF, (SAE J1926-3), or 7/16-20 UNF (SAE J1926-3) - Pressure range: 1 bar to 70 bar | 100 kPa to 7 MPa | 15 psi to 1000 psi. - Pressure reference: Absolute, sealed gage, or vented gage. - Output transfer function: Ratiometric, regulated, or current. - Two available flame retardant options: UL 94 HB is standard on all electrical - terminations, UL 94 V-0 is available upon request. ## **SHORT LEAD TIME** Due to the PX2 Series’ configurability, customers can count on a quick response to prototypes. Additionally, dedicated teams and manufacturing processes ensure that product samples are shipped quickly to support your demanding product development cycle. *Competitive Differentiator **3** sensing.honeywell.com Features and Benefits _**Dependable, consistent performance.**_ =0LFLFCFCCti“‘;‘C*S ## **SMALL TOTAL ERROR BAND (TEB)** Honeywell specifies TEB, the most comprehensive, clear, and meaningful measurement that provides the transducer’s true accuracy over a compensated temperature range of -40 °C to 125 °C [-40 °F to 257 °F] (see Figure 1). **==> picture [254 x 248] intentionally omitted <==** **----- Start of picture text -----**<br> All Possible Errors<br>Offset<br>+<br>Full Scale Span<br>+<br>Pressure Non-Linearity<br>+<br>Pressure Hysteresis = Accuracy<br>+ = Total<br>Error Band<br>Pressure Non-Repeatability<br>= ee<br>+<br>Thermal Effect on Offset<br>+<br>Thermal Effect on Span<br>+<br>Thermal Hysteresis<br>**----- End of picture text -----**<br> Figure 1: TEB For the PX2 Series The PX2 Series’ industry-leading TEB of ±2%: - Provides excellent transducer interchangeability due to minimal part-to-part variation in accuracy. - Reduces the customers’ need for individual transducer testing and calibration. - Supports system accuracy and warranty requirements. ## **FAST RESPONSE TIME** A fast response time of <2 ms helps maximize system performance. ## **APPLICATION LIFE** A minimum 10 million cycles to operating pressure provides enhanced life in the application. **4** sensing.honeywell.com Features and Benefits ## **ENERGY EFFICIENT*** AC and AD output transfer functions offer a 3.3 V ratiometric output with a <7 ms turn on time, enabling the PX2 Series to be used when energy efficiency is a key requirement. ## **SIX SIGMA DESIGN STANDARDS*** Results in a high level of quality, performance, and consistency so that customers are assured that the transducer will perform to specification. ## _**Durability improves output and endurance.**_ ## **ENVIRONMENTALLY TOUGH** Compatibility with a wide variety of harsh media, up to IP69K ingress protection, and 100 V/m radiated immunity allow for use in tough environments. Sensor has overvoltage, reverse voltage, and short circuit protection. ## **WIDE OPERATING TEMPERATURE RANGE** A compensated operating temperature range of -40 °C to 125 °C [-40 °F to 257 °F] allows customers to design the same sensor into a variety of applications. ## **SHOCK AND VIBRATION RESISTANT** A mechanical shock rating of 100 G per MIL-STD-202F, Method 213B, Cond. F, and a vibration rating of 20 G sweep, 10 Hz to 2000 Hz, increase flexibility of use within the application. ## **GOOD EMC PROTECTION** Provides confidence that the transducer will not be damaged by environmental electromagnetic interference. Radiated immunity protection up to 100 V/m (ISO 11452-2) is available. *Competitive Differentiator **5** sensing.honeywell.com ## Potential Applications ## **INDUSTRIAL** ## **HVAC/R** May be used to monitor system performance for proper environmental control of: - Compressor inlet and outlet pressure - Rooftop chillers - Compressor rack rooms - Refrigerant recovery systems - Compressor oil pressure ## **AIR COMPRESSORS** May be used to monitor compressor performance and efficiency, specifically: - Compressor inlet and outlet pressure - Cooling water inlet and outlet pressure - Compressor oil pressure - Filter pressure drop ## **GENERAL** May be used to monitor air and fluid pressure in the following applications: - Emissions monitoring - Factory automation - Flow and level - Fluid power - Foam dispensing - Injection molding knock-out valves - Lasers - Laminating equipment - Packaging equipment - Pneumatics - Pumps - Solar energy - Sprayers - System pressure - Valves **6** sensing.honeywell.com Heavy Duty Pressure Transducers ## **Table 1. Electrical Specifications** **==> picture [542 x 384] intentionally omitted <==** **----- Start of picture text -----**<br> Current<br>Ratiometric Output Regulated Output<br>Output<br>Characteristic<br>Output Transfer Function Order Code [1]<br>AA AB AC AD CH BC BD BE BG<br>Output transfer function [1] :<br> null output value 10% of Vs 5% of Vs 10% of Vs 5% of Vs 4 mA 1 V 0.25 V 0.5 V 1 V<br> full scale output value 90% of Vs 95% of Vs 90% of Vs 95% of Vs 4 mA 6 V 10.25 V 4.5 V 5 V<br> full scale span (FSS) 80% of Vs 90% of Vs 80% of Vs 90% of Vs 16 mA 5 V 10 V 4 V 4 V<br> operating supply voltage, min.(Vs) [2] 4.75 V 4.5 V 3.135 V 3.135 V 8 V 9 V 13 V 8 V 8 V<br> operating supply voltage, typ. (Vs) [2] 5 V 5 V 3.3 V 3.3 V — — — — —<br> operating supply voltage, max. (Vs) [2] 5.25 V 5.5 V 3.465 V 3.465 V 30 V [4] 30 V [3] 30 V [3] 30 V [3] 30 V [3]<br>Supply current (typ.) 5 mA 4 mA — 5.5 mA<br>Output load (pull up or down)<br> minimum 2 kOhm — 2 kOhm<br> maximum — (Vs - 8) x —<br>50 Ohm [4]<br>Absolute voltage ratings [5] :<br> minimum [6] -16 V -16 V -16 V<br> maximum [6] 16 V 30 V 30 V<br> maximum applied to output pin Vs — 12 V<br> (short circuit protection) [7]<br>EMC rating [8] :<br> CE compliance:<br> electrostatic discharge ±4 kV contact, ±8 kV air per IEC 61000-4-2<br> radiated immunity 10 V/m (80 MHz to 1000 MHz) per IEC 61000-4-3<br> fast transient burst ±1 kV per IEC61000-4-4<br> immunity to conducted disturbances 3 V per IEC61000-4-6<br> radiated emissions 40 dB 30 MHz to 230 MHz; 47 dB 230 MHz to 1000 MHz per CISPR 11<br> ISO 11452-2:<br> radiated immunity 100 V/m 200 MHz to 2 GHz 20 V/m 200 MHz to 2 GHz<br>**----- End of picture text -----**<br> 1Output transfer function options are shown in the Nomenclature and Order Guide. (See Figure 4.) 2Transducer will not produce valid output when supply voltage is outside of operating range. 3Applies at 25 °C. See Figure 2 for Regulated Output Supply Voltage. 4Applies at 25 °C. See Figure 3 for Current Output Supply Voltage. 5Absolute maximum ratings are the extreme limits the device can withstand without damage to the product. Voltages above these ratings may cause permanent damage. Exposure to absolute maximum conditions for extended periods may degrade device reliability. 6Absolute voltage applies to potential across power and ground terminals. 7Short circuit protection between output pin and ground, and output pin and supply pin. 8All EMC ratings verified with the Delphi Metri-Pack 150 electrical connector type. **Figure 2. Regulated Output Supply Voltage** **==> picture [192 x 153] intentionally omitted <==** **Figure 3. Current Output Supply Voltage** **==> picture [244 x 155] intentionally omitted <==** **7** sensing.honeywell.com ## PX2 Series **Table 2. Performance Specifications[1]** **==> picture [542 x 193] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Parameter<br>Operating temperature range [2] -40 °C to 125 °C [-40 °F to 257 °F]<br>Storage temperature range [3] -40 °C to 125 °C [-40 °F to 257 °F]<br>Compensated temperature range [4] -40 °C to 125 °C [-40 °F to 257 °F]<br>Overpressure minimum rating [5] (See Table 3.)<br>Burst pressure minimum rating [6] (See Table 3.)<br>Long term stability ±0.5 %FSS [9 ] (1000 hr at 25 °C [77 °F])<br>Accuracy [7] ±0.25 %FSS [9] (See Figure 1.)<br>Offset error [8] ±1 %FSS [9]<br>Total Error Band [10] ±2 %FSS [9] (-40 °C to 125 °C [-40°F to 257 °F]) (See Figure 1.)<br>Response time [11] <2 ms<br>Turn on time [12] <7 ms<br>Life [13] min. of 10 million cycles to operating pressure<br>**----- End of picture text -----**<br> 1All specifications apply at 25 °C and under operating conditions unless otherwise noted. 2Operating Temperature Range: The temperature range over which the product will produce an output proportional to pressure but may not remain within the specified performance limits. 3Storage Temperature Range: The temperature range over which the product may safely be exposed without excitation or pressure applied. Under these conditions the product will remain in specification after excursion to any temperatures within this range. Exposure to temperatures outside this range may cause permanent damage to the product. 4Compensated Temperature Range: The temperature range (or ranges) over which the product will produce an output proportional to pressure within the specified performance limits. 5Overpressure: The absolute maximum rating for pressure which may be safely applied to the product for it to remain in specification once pressure is returned to the operating pressure range. Exposure to higher pressure may cause permanent damage to the product. 6Burst Pressure: The maximum pressure that may be applied to the product without causing escape of the pressure media. The product should not be expected to function after exposure to any pressure beyond the rated burst pressure. This rating is also the case burst rating of the product. 7Accuracy: The maximum deviation in output from a Best Fit Straight Line (BFSL) fitted to the output measured over the pressure range at 25 °C. Includes all errors due to pressure non-linearity, pressure hysteresis, and non-repeatability. 8Offset Error: the maximum deviation in the output signal obtained when the reference pressure is applied at 25 °C relative to the ideal transfer function. 9Full Scale Span (FSS): The algebraic difference between the output signal measured at the maximum (Pmax.) and minimum (Pmin.) limits of the pressure range. 10Total Error Band: The maximum deviation from the ideal transfer function over the entire compensated temperature and pressure range. Includes all errors due to offset, full scale span, pressure non-linearity, pressure hysteresis, repeatability, thermal effect on offset, thermal effect on span, and thermal hysteresis. 11Response Time: The response time of the transducer is the maximum amount of time that the transducer will take for the transducer to output a change from 10% to 90% of full scale in response to a 0% to 100% full scale step input pressure range. 12Turn On Time: Duration from power applied until first valid output. 13Life may vary depending on the application in which transducer is used. Contact Honeywell Sales and Service for Mean Time to Failure (MTTF) data based on customer-specific usage profile. **8** sensing.honeywell.com ## Heavy Duty Pressure Transducers **Table 3. Pressure Ratings** **==> picture [544 x 255] intentionally omitted <==** **----- Start of picture text -----**<br> bar kPa MPa psi<br>Operating Over- Burst Operating Over- Burst Operating Over- Burst Operating Over- Burst<br>Pressure pressure Pressure Pressure pressure Pressure Pressure pressure Pressure Pressure pressure Pressure<br>1 5 8 100 500 800 1 3.1 5.1 15 70 115<br>1.6 5 8 160 1000 1700 1.6 5.2 8.6 30 150 250<br>2 10 17 250 1000 1700 2.5 6.9 10.3 50 250 400<br>2.5 10 17 400 1700 2700 4 6.9 10.3 100 450 750<br>4 17 27 600 3100 5100 4.6 6.9 10.3 150 450 750<br>6 31 51 — 6 13.8 20.6 200 750 1250<br>8 31 51 — 7 13.8 20.6 250 750 1250<br>10 31 51 — — 300 1000 1500<br>16 52 86 — — 500 1000 1500<br>25 69 103 — — 600 1000 1500<br>34 69 103 — — 667 1000 1500<br>40 69 103 — — 750 1500 2250<br>46 69 103 — — 800 1500 2250<br>60 138 206 — — 850 2000 3000<br>70 138 206 — — 1000 2000 3000<br>**----- End of picture text -----**<br> **Table 4. Pressure Reference Types** **==> picture [542 x 106] intentionally omitted <==** **----- Start of picture text -----**<br> Pressure Reference Description<br>Output is proportional to the difference between applied pressure and a built-in fixed reference to vacuum (zero<br>Absolute<br>pressure), where the minimum operating pressure is set to absolute zero pressure (perfect vacuum).<br>Output is proportional to the difference between applied pressure and a built-in fixed reference to<br>Sealed gage [1]<br>1 atmA, where the minimum operating pressure is set to 14.7 psiA (1 atmA).<br>Sensor measures pressure relative to ambient pressure. Output is proportional to the difference between applied<br>Vented gage [2]<br>pressure and atmospheric (ambient) pressure, where the minimum operating pressure is set to atmospheric pressure.<br>**----- End of picture text -----**<br> 1Sealed gage option only available in pressure ranges at or above 100 psi. 2Vented gage option only available in pressure ranges between 100 psi and 667 psi. **Table 5. Mechanical Characteristics** **==> picture [543 x 193] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Parameter<br>Mechanical shock 100 G per MIL-STD-202F, Method 213B, Cond. F (at 25 °C)<br>Vibration 20 G sweep, 10 Hz to 2000 Hz (at 25 °C)<br>Enclosure rating per electrical connector type selection (See Figure 5.)<br>Wetted materials:<br> port 304 stainless steel<br> substrate alumina ceramic<br> adhesives epoxy<br> electronics glass, silicon<br>External materials:<br> housing 304 stainless steel<br> connector:<br> UL 94 HB (standard) PBT 30% GF, black<br> UL 94 V-0 (optional) PBT 30% GF, natural (beige)<br> cable jacket TPE<br>Installation torque per pressure port type (See Figure 6.)<br>**----- End of picture text -----**<br> **9** sensing.honeywell.com PX2 Series ## **Figure 4. Nomenclature and Order Guide[1]** **==> picture [415 x 673] intentionally omitted <==** **----- Start of picture text -----**<br> |||| |---|---|---| |PEPE|P|Pe| |Or|@neenls*),| |ae| |[|| **----- End of picture text -----**<br> **10** sensing.honeywell.com Heavy Duty Pressure Transducers ## **Figure 5. Electrical Connector Type Dimensions (For reference only: mm/[in].)** **==> picture [540 x 104] intentionally omitted <==** **==> picture [542 x 548] intentionally omitted <==** **----- Start of picture text -----**<br> A<br>Delphi Metri-Pack 150, Standard<br>(UL 94 HB) B C<br>Micro M12 DIN<br>J (IEC 61076-2) (EN 175301-803C)<br>Delphi Metri-Pack 150<br>(UL 94 V-0)<br>Connector: DELPHI 12078088 Connector: IEC 61076-2-101 Connector: EN 175301-803C<br>Mating Connector: DELPHI 12110192 Mating Connector: 4 POS TYPE D Mating Connector: EN 175301-803C DIN<br>IP Rating [1] : IP65 (all versions) IP Rating [1] : IP65/IP67 (absolute, sealed gage 43650C 8MM<br> versions) IP Rating [1] : IP65 (all versions)<br> IP65 (vented gage versions)<br>Voltage Current Voltage Current Voltage Current<br>Pin Pin Pin<br>Output Output Output Output Output Output<br>A GND RTN 1 V+ supply 1 GND RTN<br>B V+ supply 3 GND RTN 2 V+ supply<br>3 Vout NC<br>C Vout NC 4 Vout NC<br>PE NC NC<br>Hole Hole Hole<br>(vented gage (vented gage (vented gage<br>versions only) versions only) versions only)<br>**----- End of picture text -----**<br> 1IP rating is determined by the electrical connection chosen. **11** sensing.honeywell.com PX2 Series ## **Figure 5. Electrical Connector Type Dimensions (continued)** **==> picture [540 x 99] intentionally omitted <==** **==> picture [542 x 529] intentionally omitted <==** **----- Start of picture text -----**<br> E Cable Harness, 1 Meter [2]<br>D F Cable Harness, 2 Meter [2]<br>Deutsch<br>(DTM04-3P) G Cable Harness, 3 Meter [2, 3]<br>H Cable Harness, 5 Meter [2, 3]<br>Connector: Deutsch DTM04-3P Connector: 24 AWG with TPE Jacket<br>Mating Connector: DTM06-3S Mating Connector: Flying leads<br>IP Rating [1] : IP65, IP67, IP69K (absolute, IP Rating [1] : IP65, IP67, IP69K (absolute, sealed gage versions)<br> sealed gage versions)<br> IP65 (vented gage versions)<br>Voltage Current Voltage Current<br>Pin Wire Color Wire Color<br>Output Output Output Output<br>1 GND RTN red V+ red supply<br>2 Vout NC black GND<br>black RTN<br>3 V+ supply white Vout<br>Hole<br>(vented gage<br>versions only)<br>**----- End of picture text -----**<br> - 1IP rating is determined by the electrical connector type chosen. 2Three-wire cable is required for ratiometric and regulated outputs; two wire cable is required for current output. - 3Three meter and five meter cables are only available with Output Transfer Function **CH** = Current, 4 mA to 20 mA. **12** sensing.honeywell.com Heavy Duty Pressure Transducers ## **Figure 6. Pressure Port Type Dimensions (For reference only: mm/[in].)[1]** **==> picture [542 x 626] intentionally omitted <==** **----- Start of picture text -----**<br> 22 Hex flat to flat<br>[0.87]<br>F1 7/16-20 UNF 1/4 in 45º Flare Female Schrader (SAE J512) F2 7/16-20 UNF 45º Flare Male (SAE J513)<br>Seal: 45º cone Seal: 45º cone<br>Mating geometry: SAE J512 Mating geometry: SAE J513<br>Installation torque [2] : 17 N m [12.5 ft-lb] Installation torque [2] : 1/4 Turn from finger tight<br>“P” = 19,2<br> [0.75] 12,3<br>[0.49]<br>F3 7/16-20 UNF 37º Flare Male (SAE J514) G1 G1/4 ( ISO 1179-3)<br>Seal [3,4] : 37º cone Seal [3,4] : O-ring<br>Mating Geometry: SAE J514 Mating geometry: ISO 1179-1<br>Installation Torque [2] : 16 N m [11.8 ft-lb] Installation torque [2] : 50 N m [38.9 ft-lb]<br>“P” = 20,5<br> [0.81] 15,5<br>[0.61]<br>G2 G1/8 (ISO 1179-3) M1 M12 X 1.5 (ISO 6149-3)<br>Seal [3,4] : O-ring Seal [2,3] : O-ring<br>Mating geometry: ISO 1179-1 Mating geometry: ISO 6149-1<br>Installation torque [2] : 25 N m [18.4 ft-lb] Installation torque [2] : 25 N m [18.4 ft-lb]<br>N1 1/4–18 NPT N2 1/8–27 NPT<br>Seal: pipe thread Seal: pipe thread<br>Mating geometry: ANSI B1.20.1 Mating geometry: ANSI B1.20.1<br>Installation torque [2] : 2 to 3 turns Installation torque [2] : 2 to 3 turns<br>from finger tight from finger tight<br>S1 9/16–18 UNF (SAE J1926-3) S2 7/16–20 UNF (SAE J1926-3)<br>Seal [3,4] : O-ring Seal [3,4] : O-ring<br>Mating geometry: SAE J1926-1 Mating geometry: SAE J1926-1<br>Installation torque [2] : 30 N m [22.1 ft-lb] Installation torque [2] : 18 N m [12.3 ft-lb]<br>**----- End of picture text -----**<br> - 1See **CAUTION** on back page. - 2Straight thread maximum torque is validated to 150% of installation torque. > 3Seals for pressure port type order codes **S1** , **S2** , **M1** , **G1** and **G2** are included and assembled to the sensors. - 4O-ring material is nitrile 70 durometer -30 ºC to 125 ºC [-22 ºF to 257 ºF]. **13** sensing.honeywell.com ## **CAUTION** ## **PRODUCT DAMAGE** - Ensure torque specifications are determined for the specific application. Values provided are for reference only. NPT ports are not specified with torque values. Correct installation is based on the number of Turns From Finger Tight (TFFT). (Mating materials and thread sealants can result in significantly different torque values from one application to the next.) - When using NPT ports in stainless steel manifolds, use a thread sealant with anti-seize properties to prevent thread galling. Ensure the sealant is rated for the application. - Use appropriate tools (such as an open ended wrench or deep well socket) to install transducers. - Always hand-start transducers into the hole to prevent cross threading and damage **Failure to comply with these instructions may result in product damage.** ## **ADDITIONAL INFORMATION** The following associated literature is available at sensing.honeywell.com: - Product line guide - Product part listing/nomenclature tree - Product range guide - Technical Information: - Total Error Band Specification for Honeywell Heavy Duty Pressure Transducers, PX2 Series - Application information - Product installation instructions ## **Find out more** Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office. To learn more about Honeywell’s sensing and control products, call **+1-815-235-6847 or 1-800-537-6945** , visit **sensing.honeywell.com,** or e-mail inquiries to ## **WARNING** ## **PERSONAL INJURY** **DO NOT USE** these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. **Failure to comply with these instructions could result in death or serious injury.** ## **WARNING** ## **MISUSE OF DOCUMENTATION** - The information presented in this datasheet is for reference only. Do not use this document as a product installation guide. - Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. **Failure to comply with these instructions could result in death or serious injury.** ## **WARRANTY/REMEDY** Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. **The foregoing is buyer’s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.** While we provide application assistance personally, through our literature and the Honeywell website, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. **info.sc@honeywell.com** Sensing and Control Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 **honeywell.com** 50069942-H-EN GLO February 2015 © 2015 Honeywell International Inc. All rights reserved.
Updated at February 9, 2023
Honeywell is a globally recognized leader in the design and manufacture of advanced sensing and switching solutions. Renowned for engineering components that deliver enhanced precision and ruggedness, Honeywell provides essential technologies for demanding applications across critical healthcare, aerospace, and industrial equipment. With a comprehensive portfolio built to address both basic and complex design challenges, the company stands at the forefront of reliable electronic component manufacturing. The core of our Honeywell offering is an extensive selection of high-performance sensors and transducers. This includes a robust lineup of pressure sensors and transducers engineered for accurate fluid and gas measurement in challenging environments. Furthermore, we provide a wide array of temperature sensors and specialized temperature sensing NTC thermistors designed for stable thermal management, alongside precision current sensors and load cells that deliver critical feedback for control systems. Beyond advanced sensing technology, Honeywell’s expertise extends to essential circuit protection and electromechanical components. Our selection encompasses power relays, thermal magnetic circuit breakers, and standard terminal blocks, ensuring safe and efficient power distribution. Whether integrating core components or sourcing specialized accessories, design engineers can rely on Honeywell for uncompromising quality and operational excellence.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →