Image not available
Illustrative purposes only
PWM-90-48
LED Driver, LED Lighting, 90.24 W, 48 VDC, 1.88 A, Constant Voltage, 90 V
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC LED Power Supplies
- SVHC: No SVHC (25-Jun-2025)
- Product Range: PWM-90
- Output Current: 1.88A
- LED Driver Mode: Constant Voltage
- Output Power Max: 90.24W
- Input Voltage Max: 305V
- Input Voltage Min: 90V
- Output Voltage Max: 48VDC
- Power Supply Applications: LED Lighting
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 32.72 € |
| Current stock | 10+ |
| Lead time | 30 days |
**- PWM 90 series** 90W PWM output LED power supply ** IP67** ## ■ **** - ‧ - ‧ - ‧ - ‧ ## ■ **** - ‧ - ‧ - ‧ - ‧ - - ‧ - ‧ - ‧ - ‧Ⅱ - ‧ - ‧ - ‧ - ‧ ## ■ **** Ⅱ ℃ ## ■ **** ** ** ~~Te~~ _File Name:PWM-90-SPEC 2014-10-21_ **- PWM 90 series** 90W PWM output LED power supply ## **SPECIFICATION** ||**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**RATED POWER**<br>**OUTPUT**<br>**SETUP, RISE TIMENote.2**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**SAFETY STANDARDS**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVER LOAD**<br>**OVER VOLTAGE**<br>**SHORT CIRCUIT**<br>**OVER TEMPERATURE**<br>12V<br>24V<br>36V<br>48V<br>7.5A<br>3.75A<br>2.5A<br>1.88A<br>90W<br>90W<br>90W<br>90.24W<br>0 ~ 100%<br>300Hz<br>±4.0%<br>±3.0%<br>±2.0%<br>±1.0%<br>500ms, 80ms 115VAC / 230VAC at full load<br>16ms/230VAC 16ms/115VAC at full load<br>90 ~ 305VAC 127 ~ 431VDC<br>47 ~ 63Hz<br>PF>0.98/115VAC, PF>0.96/230VAC, PF>0.94/277VAC at full load (Please refer to "Power Factor Characteristic" curve)<br>88%<br>90.5%<br>90.5%<br>90.5%<br><0.25mA / 277VAC<br>108 ~ 120% rated output power<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>Hiccup mode, recovers automatically after fault condition is removed<br>-40 ~ +70℃(Refer to "Derating Curve")<br>20 ~ 95% RH non-condensing<br>-40 ~ +80℃, 10 ~ 95% RH<br>±0.03%/℃(0 ~ 50℃)<br>10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes<br>224.2K hrs min. MIL-HDBK-217F (25℃)<br>171*63*37.5mm (L*W*H)<br>℃<br><br>0.77Kg; 18pcs/14.9Kg/0.82CUFT<br>**DIMMING RANGE**<br>**PWM FREQUENCY (Typ.)**<br>**VOLTAGE TOLERANCE**<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**PROTECTION**<br>15 ~ 17V<br>28 ~ 34V<br>41 ~ 46V<br>54 ~ 60V<br>0.95A / 115VAC 0.5A / 230VAC 0.4A / 277VAC<br>**PWM-90-12**<br>**PWM-90-24**<br>**PWM-90-36**<br>**PWM-90-48**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3.75KVAC<br>I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH<br>**EMC IMMUNITY**<br>Compliance to EN55015, EN61000-3-2 Class C (≧60% load) ; EN61000-3-3<br>Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level(surge L- N : 2KV), criteria A<br>**EMC EMISSION**<br>UL8750, CSA C22.2 No. 250.<br>, ENEC EN61347-1, EN61347-2-13, EN62384 independent, IP67 approved ;<br>13-12<br>Design refer to EN60335-1<br>COLD START 60A(twidth=550 s measured at 50% Ipeak) at 230VAC<br>μ<br>**TOTAL HARMONIC DISTORTION** THD< 20% when output loading≧60% at 115VAC/230VAC input and output loading≧75% at 277VAC input<br>Shut down o/p voltage, re-power on to recover<br>Protection type :Shut down o/p voltage, re-power on to recover|**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**RATED POWER**<br>**OUTPUT**<br>**SETUP, RISE TIMENote.2**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**SAFETY STANDARDS**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVER LOAD**<br>**OVER VOLTAGE**<br>**SHORT CIRCUIT**<br>**OVER TEMPERATURE**<br>12V<br>24V<br>36V<br>48V<br>7.5A<br>3.75A<br>2.5A<br>1.88A<br>90W<br>90W<br>90W<br>90.24W<br>0 ~ 100%<br>300Hz<br>±4.0%<br>±3.0%<br>±2.0%<br>±1.0%<br>500ms, 80ms 115VAC / 230VAC at full load<br>16ms/230VAC 16ms/115VAC at full load<br>90 ~ 305VAC 127 ~ 431VDC<br>47 ~ 63Hz<br>PF>0.98/115VAC, PF>0.96/230VAC, PF>0.94/277VAC at full load (Please refer to "Power Factor Characteristic" curve)<br>88%<br>90.5%<br>90.5%<br>90.5%<br><0.25mA / 277VAC<br>108 ~ 120% rated output power<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>Hiccup mode, recovers automatically after fault condition is removed<br>-40 ~ +70℃(Refer to "Derating Curve")<br>20 ~ 95% RH non-condensing<br>-40 ~ +80℃, 10 ~ 95% RH<br>±0.03%/℃(0 ~ 50℃)<br>10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes<br>224.2K hrs min. MIL-HDBK-217F (25℃)<br>171*63*37.5mm (L*W*H)<br>℃<br><br>0.77Kg; 18pcs/14.9Kg/0.82CUFT<br>**DIMMING RANGE**<br>**PWM FREQUENCY (Typ.)**<br>**VOLTAGE TOLERANCE**<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**PROTECTION**<br>15 ~ 17V<br>28 ~ 34V<br>41 ~ 46V<br>54 ~ 60V<br>0.95A / 115VAC 0.5A / 230VAC 0.4A / 277VAC<br>**PWM-90-12**<br>**PWM-90-24**<br>**PWM-90-36**<br>**PWM-90-48**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3.75KVAC<br>I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH<br>**EMC IMMUNITY**<br>Compliance to EN55015, EN61000-3-2 Class C (≧60% load) ; EN61000-3-3<br>Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level(surge L- N : 2KV), criteria A<br>**EMC EMISSION**<br>UL8750, CSA C22.2 No. 250.<br>, ENEC EN61347-1, EN61347-2-13, EN62384 independent, IP67 approved ;<br>13-12<br>Design refer to EN60335-1<br>COLD START 60A(twidth=550 s measured at 50% Ipeak) at 230VAC<br>μ<br>**TOTAL HARMONIC DISTORTION** THD< 20% when output loading≧60% at 115VAC/230VAC input and output loading≧75% at 277VAC input<br>Shut down o/p voltage, re-power on to recover<br>Protection type :Shut down o/p voltage, re-power on to recover|**PWM-90-12**|**PWM-90-24**|**PWM-90-36**|**PWM-90-48**| |---|---|---|---|---|---|---| |||**DC VOLTAGE**|12V|24V|36V|48V| |||**RATED CURRENT**|7.5A|3.75A|2.5A|1.88A| |||**RATED POWER**|90W|90W|90W|90.24W| |||**DIMMING RANGE**|0 ~ 100%|||| |||**PWM FREQUENCY (Typ.)**|300Hz|||| |||**VOLTAGE TOLERANCE**|±4.0%|±3.0%|±2.0%|±1.0%| |||**SETUP, RISE TIMENote.2**|500ms, 80ms 115VAC / 230VAC at full load|||| |||**HOLD UP TIME (Typ.)**|16ms/230VAC 16ms/115VAC at full load|||| |||**VOLTAGE RANGE**|90 ~ 305VAC 127 ~ 431VDC|||| |||**FREQUENCY RANGE**|47 ~ 63Hz|||| |||**POWER FACTOR (Typ.)**|PF>0.98/115VAC, PF>0.96/230VAC, PF>0.94/277VAC at full load (Please refer to "Power Factor Characteristic" curve)|||| |||**TOTAL HARMONIC DISTORTION**|THD< 20% when output loading≧60% at 115VAC/230VAC input and output loading≧75% at 277VAC input|||| |||**EFFICIENCY (Typ.)**|88%|90.5%|90.5%|90.5%| |||**AC CURRENT (Typ.)**|0.95A / 115VAC 0.5A / 230VAC 0.4A / 277VAC|||| |||**INRUSH CURRENT (Typ.)**|COLD START 60A(twidth=550 s measured at 50% Ipeak) at 230VAC<br>μ|||| |||**LEAKAGE CURRENT**|<0.25mA / 277VAC|||| |||**OVER LOAD**|108 ~ 120% rated output power<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed|||| |||**SHORT CIRCUIT**|Hiccup mode, recovers automatically after fault condition is removed|||| |||**OVER VOLTAGE**|15 ~ 17V<br>28 ~ 34V<br>41 ~ 46V<br>54 ~ 60V<br>Protection type :Shut down o/p voltage, re-power on to recover|||| |||**OVER TEMPERATURE**|Shut down o/p voltage, re-power on to recover|||| |||**WORKING TEMP.**|-40 ~ +70℃(Refer to "Derating Curve")|||| |||**WORKING HUMIDITY**|20 ~ 95% RH non-condensing|||| |||**STORAGE TEMP., HUMIDITY**|-40 ~ +80℃, 10 ~ 95% RH|||| |||**TEMP. COEFFICIENT**|±0.03%/℃(0 ~ 50℃)|||| |||**VIBRATION**|10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes|||| |||**SAFETY STANDARDS**|UL8750, CSA C22.2 No. 250.<br>, ENEC EN61347-1, EN61347-2-13, EN62384 independent, IP67 approved ;<br>13-12<br>Design refer to EN60335-1|||| |||**WITHSTAND VOLTAGE**|I/P-O/P:3.75KVAC|||| |||**ISOLATION RESISTANCE**|I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH|||| |||**EMC EMISSION**|Compliance to EN55015, EN61000-3-2 Class C (≧60% load) ; EN61000-3-3|||| |||**EMC IMMUNITY**|Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level(surge L- N : 2KV), criteria A|||| |||**MTBF**|224.2K hrs min. MIL-HDBK-217F (25℃)|||| |||**DIMENSION**|171*63*37.5mm (L*W*H)|||| |||**PACKING**|0.77Kg; 18pcs/14.9Kg/0.82CUFT|||| |||℃<br>||||| _File Name:PWM-90-SPEC 2014-10-21_ **- PWM 90 series** ## 90W PWM output LED power supply ## **Block Diagram** **==> picture [487 x 601] intentionally omitted <==** **----- Start of picture text -----**<br> PFC fosc : 50~120KHz<br>PWM fosc : 60~130KHz<br>EMI FILTER PFC POWER RECTIFIERS +V<br>I/P & CIRCUIT SWITCHING & DIMMING -V<br>RECTIFIERS FILTER CIRCUIT<br>O.L.P. DIM+<br>DIM-<br>O.T.P. O.L.P. DETECTION<br>PWM & PFC CIRCUIT<br>CONTROL<br>O.V.P.<br>Derating Curve Static Characteristics<br>100<br>100<br>90<br>80 80<br>230VAC<br>Input only 70<br>60<br>50 60<br>40<br>50<br>20 40<br>-40 -25 -10 0 15 30 50 60 70 (HORIZONTAL) 90 100 125 135 145 155 165 175 180 200 230 305<br>AMBIENT TEMPERATURE ( ℃ ) INPUT VOLTAGE (V) 60Hz<br>Power Factor Characteristic<br>Constant Voltage Mode<br>1.00<br>0.90<br>0.80<br>0.70<br>0.60<br>277V<br>0.50<br>0.40 230V<br>0.30 115V<br>0.20<br>0.10<br>0.00<br>10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>(90W)<br>LOAD<br>LOAD (%) LOAD (%)<br>PF<br>**----- End of picture text -----**<br> _File Name:PWM-90-SPEC 2014-10-21_ **- PWM 90 series** 90W PWM output LED power supply ## **EFFICIENCY vs LOAD (48V Model)** PWM-90 series possess superior working efficiency that up to 90.5% can be reached in field applications. **==> picture [432 x 188] intentionally omitted <==** **----- Start of picture text -----**<br> 94<br>92<br>90<br>88<br>86 277V<br>84 230V<br>82<br>115V<br>80<br>78<br>76<br>10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>EFFICIENCY (%)<br>**----- End of picture text -----**<br> **LOAD** ## **DIMMING OPERATION** The PWM style output is a simple switching of supply ON/OFF at a rate so fast that the human eye cannot see led flickering. Duty cycle describes the proportion of time when output voltage is on relative to the entire period of time. It is expressed in percentage, 100% being fully on (maximal brightness) and a low duty cycle corresponding to lower brightness. Built-in 3 in 1 dimming function. The duty of the PWM style output can be adjusted through output cable by connecting a 0~10Vdc or 10V PWM signal or resistance between DIM+ and DIM-. ## ◎ **Connection** **==> picture [339 x 119] intentionally omitted <==** **----- Start of picture text -----**<br> LED Strips<br>+<br>+V +<br>-<br>-V -<br>DIM+<br>+<br>0~10Vdc or 10V PWM or resistance control dimmer<br>DIM- -<br>**----- End of picture text -----**<br> ※DO NOT connect "DIM- to -V" _File Name:PWM-90-SPEC 2014-10-21_ **- PWM 90 series** ## 90W PWM output LED power supply **==> picture [511 x 668] intentionally omitted <==** **----- Start of picture text -----**<br> ◎ Duty cycle of output current VS Dimming input<br>100% when DIM+/DIM- are open circuit.<br>100%<br>90%<br>80%<br>70%<br>Non-Linear<br>60%<br>50%<br>40%<br>30%<br>20%<br>10%<br>0%<br>0V 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V 0~10Vdc<br>0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Duty cycle of 10V PWM (frequency range = 100~3KHz)<br>0K 10K 20K 30K 40K 50K 60K 70K 80K 90K 100K 0~100KΩresistance<br>Dimming input<br>◎ PWM Style Output<br>ON<br>Output DC current TON<br>Duty cycle(%) = ×100%<br>T<br>OFF Output PWM frequency : 300Hz fixed (Typ.)<br>TON<br>T<br>Mechanical Specification<br>Case No. PWM-90P Unit:mm<br>171<br>5<br>5<br>300±20 300±20<br>AC/L(Brown)AC/N(Blue) SJTW 18AWG×2C 85.5 SJTW 16AWG×2C +V(Red)-V(Black)<br>DIM+(Blue)<br>DIM-(White)<br>UL2464 18AWG×2C<br>5<br>5<br>※ T case: Max. Case Temperature.<br>Recommend Mounting Direction<br>2-<br>ψ<br>4.5<br>Duty cycle of output current<br>63<br>31.5<br>37.5<br>**----- End of picture text -----**<br> _File Name:PWM-90-SPEC 2014-10-21_ **- PWM 90 series** ## 90W PWM output LED power supply ## **Installation Manual** **==> picture [471 x 225] intentionally omitted <==** **----- Start of picture text -----**<br> ◎ Connection<br>+V(RED) +<br>AC/L(BROWN) LED Strip<br>-<br>-V(BLACK)<br>AC/N(BLUE)<br>DIM+(BLUE)<br>+<br>0~10Vdc or 10V PWM<br>- or resistance Dimmer<br>DIM-(WHITE)<br>**----- End of picture text -----**<br> ## ◎ **Cautions** - ‧ Before commencing any installation or maintenance work, please disconnect the power supply from the utility. Ensure - that it cannot be re-connected inadvertently! - ‧Keep proper ventilation around the unit and do not stack any object on it. Also a 10-15 cm clearance must be kept when the adjacent device is a heat source. - ‧Mounting orientations other than standard orientation or operate under high ambient temperature may increase the internal component temperature and will require a de-rating in output current. - ‧ Current rating of an approved primary /secondary cable should be greater than or equal to that of the unit. Please refer - to its specification. - ‧ For LED power supplies with waterproof connectors, verify that the linkage between the unit and the lighting fixture is - tight so that water cannot intrude into the system. - ‧ For dimmable LED power supplies, make sure that your dimming controller is capable of driving these units.PWM series - require 0.15mA each unit. - ‧ Tc max. is identified on the product label. Please make sure that temperature of Tc point will not exceed limit. - ‧DO NOT connect "DIM+ to -V". - ‧ Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 - minutes. - ‧ The power supply is considered as a component that will be operated in combination with final equipment. Since EMC - performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. - ‧For more information about installation, please refer to www.meanwell.com/webnet/search/installationsearch.html for details. _File Name:PWM-90-SPEC 2014-10-21_
Updated at April 17, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →