- Manufacturer: MEAN WELL
- Product type: AC / DC LED Power Supplies
- SVHC: No SVHC (25-Jun-2025)
- Product Range: PWM-60
- Output Current: 1.67A
- LED Driver Mode: Constant Voltage
- Output Power Max: 60.12W
- Input Voltage Max: 305V
- Input Voltage Min: 90V
- Output Voltage Max: 36VDC
- Power Supply Applications: LED Lighting
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 32.64 € |
| Current stock | 10+ |
| Lead time | 30 days |
60W PWM Output LED Driver ## **- PWM 60 series** - **IS 15885(Part 2/Sec13)** - (for DA-Type only) ~~=P oPO~~ **** VVV ** ** **IP67** Cz **R-41027766** THOMAS SAMUEL THOMAS SAMUEL Abus **** Abus **** Ks © CB CE EH - ■ **** ■ **** - ‧ ‧ ‧ - ‧ ‧ - ‧ ‧ ‧ ‧ - ‧ - ‧ - ‧ - ‧ - ‧ ■ **** ~ - - ℃℃ - ■ ** ** LJ ~~Ud~~ ||||| |---|---|---|---| ||||| ||||| _File Name:PWM-60-SPEC 2019-01-10_ **- PWM 60 series** 60W PWM Output LED Driver ## **SPECIFICATION** ||**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**RATED POWER**<br>**OUTPUT**<br>**SETUP, RISE TIMENote.2**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGENote.3**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**SAFETY STANDARDS Note.5**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**OVER TEMPERATURE**<br>0 ~ 100%<br>1.47kHz<br>500ms, 80ms/ 115AC or 230VAC<br>16ms/115VAC or 230VAC<br>90 ~ 305VAC 127 ~ 431VDC<br>47 ~ 63Hz<br>PF>0.97/115VAC, PF>0.95/230VAC, PF>0.92/277VAC @ full load<br>(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)<br><0.25mA / 277VAC<br>108 ~ 125% rated output power<br>Hiccup mode, recovers automatically after fault condition is removed<br>20 ~ 95% RH non-condensing<br>-40 ~ +80℃, 10 ~ 95% RH<br>10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes<br>996K hrs min. Telcordia SR-332 (Bellcore) ; 271.03K hrs min. MIL-HDBK-217F (25℃)<br>℃<br><br><br><br><br>℃<br><br>℃℃<br><br><br>**DIMMING RANGE**<br>**PWM FREQUENCY (Typ.)**<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**PROTECTION**<br>Shut down o/p voltage, re-power on to recover<br>15 ~ 17V<br>28 ~ 34V<br>41 ~ 46V<br>54 ~ 60V<br>**PWM-60-12**<br>**PWM-60-24**<br>**PWM-60-36**<br>**PWM-60-48**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3.75KVAC<br>I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH<br>**EMC IMMUNITY**<br>Compliance to EN55015, EN61000-3-2 Class C (@load≧60%) ; EN61000-3-3,GB17743 and GB17625.1,EAC TP TC 020<br>Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level (surge immunity Line-Line 2KV),EAC TP TC 020<br>**EMC EMISSION Note.6**<br>COLD START 50A(twidth=270 s measured at 50% Ipeak) at 230VAC<br>;Per NEMA 410<br>μ<br>**TOTAL HARMONIC DISTORTION**<br>**MAX. NO. of PSUs on 16A**<br>**CIRCUIT BREAKER**<br>9 units (circuit breaker of type B) / 16 units (circuit breaker of type C) at 230VAC<br>**SHORT CIRCUIT**<br>(Please refer to "STATIC CHARACTERISTIC" section)<br>THD< 20%(@load≧60%/115VAC, 230VAC; @load≧75%/277VAC)<br>(Please refer to “TOTAL HARMONIC DISTORTION” section)<br><0.5W<br>****<br>Tcase=-40 ~ +<br>(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)<br>85℃<br>Tcase=+85℃<br>**MAX. CASE TEMP.**<br>UL8750( type ”HL” )( except for DA-Type), UL879( for 12V,24V Blank Type only), CSA C22.2 No. 250.13-12; ENEC EN61347-1,<br>EN61347-2-13 independent,EN62384, IP67,BIS IS15885(for 12,24,48 Blank Type only), EAC TP TC 004, GB19510.1,<br>GB19510.14 approved; Design refer to EN60335-1<br>86%<br>89%<br>90%<br>90%<br>±0.03%/℃(0 ~ 50℃)<br>0.49Kg;30pcs/15.7Kg/1.0CUFT<br>150*53*35mm (L*W*H)<br>Shut down o/p voltage, re-power on to recover<br>12V<br>24V<br>36V<br>48V<br>5A<br>2.5A<br>1.67A<br>1.25A<br>60W<br>60W<br>60.12W<br>60W<br>0.8A / 115VAC 0.4A / 230VAC 0.32A / 277VAC<br>Shut down o/p voltage, re-power on to recover<br>**DALI STANDARDS**<br>Comply with IEC62386-101, 102, 207 for DA-Type only,Device type 6(DT6)|**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**RATED POWER**<br>**OUTPUT**<br>**SETUP, RISE TIMENote.2**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGENote.3**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**SAFETY STANDARDS Note.5**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**OVER TEMPERATURE**<br>0 ~ 100%<br>1.47kHz<br>500ms, 80ms/ 115AC or 230VAC<br>16ms/115VAC or 230VAC<br>90 ~ 305VAC 127 ~ 431VDC<br>47 ~ 63Hz<br>PF>0.97/115VAC, PF>0.95/230VAC, PF>0.92/277VAC @ full load<br>(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)<br><0.25mA / 277VAC<br>108 ~ 125% rated output power<br>Hiccup mode, recovers automatically after fault condition is removed<br>20 ~ 95% RH non-condensing<br>-40 ~ +80℃, 10 ~ 95% RH<br>10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes<br>996K hrs min. Telcordia SR-332 (Bellcore) ; 271.03K hrs min. MIL-HDBK-217F (25℃)<br>℃<br><br><br><br><br>℃<br><br>℃℃<br><br><br>**DIMMING RANGE**<br>**PWM FREQUENCY (Typ.)**<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**PROTECTION**<br>Shut down o/p voltage, re-power on to recover<br>15 ~ 17V<br>28 ~ 34V<br>41 ~ 46V<br>54 ~ 60V<br>**PWM-60-12**<br>**PWM-60-24**<br>**PWM-60-36**<br>**PWM-60-48**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3.75KVAC<br>I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH<br>**EMC IMMUNITY**<br>Compliance to EN55015, EN61000-3-2 Class C (@load≧60%) ; EN61000-3-3,GB17743 and GB17625.1,EAC TP TC 020<br>Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level (surge immunity Line-Line 2KV),EAC TP TC 020<br>**EMC EMISSION Note.6**<br>COLD START 50A(twidth=270 s measured at 50% Ipeak) at 230VAC<br>;Per NEMA 410<br>μ<br>**TOTAL HARMONIC DISTORTION**<br>**MAX. NO. of PSUs on 16A**<br>**CIRCUIT BREAKER**<br>9 units (circuit breaker of type B) / 16 units (circuit breaker of type C) at 230VAC<br>**SHORT CIRCUIT**<br>(Please refer to "STATIC CHARACTERISTIC" section)<br>THD< 20%(@load≧60%/115VAC, 230VAC; @load≧75%/277VAC)<br>(Please refer to “TOTAL HARMONIC DISTORTION” section)<br><0.5W<br>****<br>Tcase=-40 ~ +<br>(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)<br>85℃<br>Tcase=+85℃<br>**MAX. CASE TEMP.**<br>UL8750( type ”HL” )( except for DA-Type), UL879( for 12V,24V Blank Type only), CSA C22.2 No. 250.13-12; ENEC EN61347-1,<br>EN61347-2-13 independent,EN62384, IP67,BIS IS15885(for 12,24,48 Blank Type only), EAC TP TC 004, GB19510.1,<br>GB19510.14 approved; Design refer to EN60335-1<br>86%<br>89%<br>90%<br>90%<br>±0.03%/℃(0 ~ 50℃)<br>0.49Kg;30pcs/15.7Kg/1.0CUFT<br>150*53*35mm (L*W*H)<br>Shut down o/p voltage, re-power on to recover<br>12V<br>24V<br>36V<br>48V<br>5A<br>2.5A<br>1.67A<br>1.25A<br>60W<br>60W<br>60.12W<br>60W<br>0.8A / 115VAC 0.4A / 230VAC 0.32A / 277VAC<br>Shut down o/p voltage, re-power on to recover<br>**DALI STANDARDS**<br>Comply with IEC62386-101, 102, 207 for DA-Type only,Device type 6(DT6)|**PWM-60-12**|**PWM-60-24**|**PWM-60-36**|**PWM-60-48**| |---|---|---|---|---|---|---| |||**DC VOLTAGE**|12V|24V|36V|48V| |||**RATED CURRENT**|5A|2.5A|1.67A|1.25A| |||**RATED POWER**|60W|60W|60.12W|60W| |||**DIMMING RANGE**|0 ~ 100%|||| |||**PWM FREQUENCY (Typ.)**|1.47kHz|||| |||**SETUP, RISE TIMENote.2**|500ms, 80ms/ 115AC or 230VAC|||| |||**HOLD UP TIME (Typ.)**|16ms/115VAC or 230VAC|||| |||**VOLTAGE RANGENote.3**|<br>90 ~ 305VAC 127 ~ 431VDC<br>(Please refer to "STATIC CHARACTERISTIC" section)|||| |||**FREQUENCY RANGE**|47 ~ 63Hz|||| |||**POWER FACTOR (Typ.)**|PF>0.97/115VAC, PF>0.95/230VAC, PF>0.92/277VAC @ full load<br>(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)|||| |||**TOTAL HARMONIC DISTORTION**|THD< 20%(@load≧60%/115VAC, 230VAC; @load≧75%/277VAC)<br>(Please refer to “TOTAL HARMONIC DISTORTION” section)|||| |||**EFFICIENCY (Typ.)**|86%|89%|90%|90%| |||**AC CURRENT (Typ.)**|0.8A / 115VAC 0.4A / 230VAC 0.32A / 277VAC|||| |||**INRUSH CURRENT (Typ.)**|COLD START 50A(twidth=270 s measured at 50% Ipeak) at 230VAC<br>;Per NEMA 410<br>μ|||| |||**MAX. NO. of PSUs on 16A**<br>**CIRCUIT BREAKER**|9 units (circuit breaker of type B) / 16 units (circuit breaker of type C) at 230VAC|||| |||**LEAKAGE CURRENT**|<0.25mA / 277VAC|||| |||****|<0.5W|||| |||**OVERLOAD**|108 ~ 125% rated output power<br>Hiccup mode, recovers automatically after fault condition is removed|||| |||**SHORT CIRCUIT**|Shut down o/p voltage, re-power on to recover|||| |||**OVER VOLTAGE**|15 ~ 17V<br>28 ~ 34V<br>41 ~ 46V<br>54 ~ 60V<br>Shut down o/p voltage, re-power on to recover|||| |||**OVER TEMPERATURE**|Shut down o/p voltage, re-power on to recover|||| |||**WORKING TEMP.**|Tcase=-40 ~ +<br>(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)<br>85℃|||| |||**MAX. CASE TEMP.**|Tcase=+85℃|||| |||**WORKING HUMIDITY**|20 ~ 95% RH non-condensing|||| |||**STORAGE TEMP., HUMIDITY**|-40 ~ +80℃, 10 ~ 95% RH|||| |||**TEMP. COEFFICIENT**|±0.03%/℃(0 ~ 50℃)|||| |||**VIBRATION**|10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes|||| |||**SAFETY STANDARDS Note.5**|UL8750( type ”HL” )( except for DA-Type), UL879( for 12V,24V Blank Type only), CSA C22.2 No. 250.13-12; ENEC EN61347-1,<br>EN61347-2-13 independent,EN62384, IP67,BIS IS15885(for 12,24,48 Blank Type only), EAC TP TC 004, GB19510.1,<br>GB19510.14 approved; Design refer to EN60335-1|||| |||**DALI STANDARDS**|Comply with IEC62386-101, 102, 207 for DA-Type only,Device type 6(DT6)|||| |||**WITHSTAND VOLTAGE**|I/P-O/P:3.75KVAC|||| |||**ISOLATION RESISTANCE**|I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH|||| |||**EMC EMISSION Note.6**|Compliance to EN55015, EN61000-3-2 Class C (@load≧60%) ; EN61000-3-3,GB17743 and GB17625.1,EAC TP TC 020|||| |||**EMC IMMUNITY**|Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level (surge immunity Line-Line 2KV),EAC TP TC 020|||| |||**MTBF**|996K hrs min. Telcordia SR-332 (Bellcore) ; 271.03K hrs min. MIL-HDBK-217F (25℃)|||| |||**DIMENSION**|150*53*35mm (L*W*H)|||| |||**PACKING**<br>℃<br><br><br><br><br>℃<br><br>℃℃<br><br><br>0.49Kg;30pcs/15.7Kg/1.0CUFT||||| _File Name:PWM-60-SPEC 2019-01-10_ **- PWM 60 series** 60W PWM Output LED Driver ## **DIMMING OPERATION** **==> picture [497 x 604] intentionally omitted <==** **----- Start of picture text -----**<br> AC/L(Brown)<br>AC/N(Blue) Vo+(Red)<br>Vo-(Black)<br>SJTW 18AWG×2C DIM+(Blue)*<br>DIM-(White)* *<br>UL2464 18AWG×2C(Vo+,Vo-)<br>UL2464 22AWG×2C(DIM+,DIM-)<br>* DIM+ for Blank-Type<br>※ Dimming principle for PWM style output DA+ for DA-type<br>‧Dimming is achieved by varying the duty cycle of the output current. * *DIM- for Blank-Type<br> DA- for DA-type<br>NOTE: DA Type is no distinction<br>between “+” and “-” poles<br>ON<br>Output DC current TON<br>Duty cycle(%) = ×100%<br>T<br>OFF Output PWM frequency : 1.47kHz fixed (Typ.)<br>Io=0A<br>TON<br>T<br>※ 3 in 1 dimming function (for Blank-Type)<br>‧Apply one of the three methodologies between DIM+ and DIM-: 0 ~ 10VDC, or 10V PWM signal or resistance.<br>‧Dimming source current from power supply: 100μA (typ.)<br>◎ Applying additive 0 ~ 10VDC 100%<br>90%<br>LED Strips 80%<br>+<br>Vo+ + 70%<br>60%<br>-<br>Vo- - 50%<br>DIM+ 40%<br>+<br>Additive Voltage 10% 30%<br>- 20%<br>DIM-<br>0.15% 10%<br>“DO NOT connect "DIM- to Vo-" 0.6V 1V 0%0V 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V<br>Dimming input: Additive voltage<br>◎ Applying additive 10V PWM signal (frequency range 100Hz ~ 3KHz): 100%<br>90%<br>LED Strips 80%<br>+<br>Vo+ + 70%<br>60%<br>-<br>Vo- - 50%<br>DIM+ 40%<br>30%<br>Additive PWM signal 10%<br>20%<br>DIM-<br>0.15% 10%<br>“DO NOT connect "DIM- to Vo-" 6% 10%<br>0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>Duty cycle of additive 10V PWM signal dimming input<br>Duty cycle of output current (%)<br>Duty cycle of output current (%)<br>**----- End of picture text -----**<br> _File Name:PWM-60-SPEC 2019-01-10_ **- PWM 60 series** 60W PWM Output LED Driver **==> picture [460 x 205] intentionally omitted <==** **----- Start of picture text -----**<br> ◎ Applying additive resistance: 100%<br>LED Strips 90%<br>Vo+ + + 80%<br>70%<br>-<br>Vo- - 60%<br>DIM+ 50%<br>40%<br>Additive Resistance<br>30%<br>10%<br>DIM- 20%<br>“DO NOT connect "DIM- to Vo-" 10%<br>6K/N 10K/N Short0% 10K/N 20K/N 30K/N 40K/N 50K/N 60K/N 70K/N 80K/N 90K/N 100K/N<br>(N=driver quantity for�synchronized�dimming operation)<br>Dimming input: Additive resistance<br>Note : 1. Min. duty cycle of output current is about 6% and the output current is not defined when 0%< Iout<6%.<br>Duty cycle of output current (%)<br>**----- End of picture text -----**<br> 2. The duty cycle of output current could drop down to 0% when dimming input is about 0kΩ or 0Vdc, or 10V PWM signal with 0% duty cycle. - ※ DALI Interface (primary side; for DA-Type) ‧Apply DALI signal between DA+ and DA-. - ‧DALI protocol comprises 16 groups and 64 addresses. - ‧First step is fixed at 0.2% of output _File Name:PWM-60-SPEC 2019-01-10_ **- PWM 60 series** 60W PWM Output LED Driver ## **OUTPUT LOAD vs TEMPERATURE** **==> picture [501 x 360] intentionally omitted <==** **----- Start of picture text -----**<br> 100 100<br>80 80<br>230VAC 230VAC<br>Input only Input only<br>60 60<br>50<br>40 40<br>20 20<br>-40 -25 -10 0 15 30 50 60 70 (HORIZONTAL) -40 -25 0 20 45 60 70 80 85 (HORIZONTAL)<br>AMBIENT TEMPERATURE,Ta ( ℃ ) Tcase ( ℃ )<br>STATIC CHARACTERISTIC POWER FACTOR (PF) CHARACTERISTIC<br>※ Tcase at 75℃<br>100<br>1.0<br>90<br>0.9<br>80 0.8<br>70 0.7 277V<br>0.6 230V<br>60<br>115V<br>0.5<br>50<br>0.4<br>40 0.3<br>10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>90 100 125 135 145 155 165 175 180 200 230 305 (60W)<br>LOAD<br>INPUT VOLTAGE (V) 60Hz<br>LOAD (%) LOAD (%)<br>PF<br>LOAD (%)<br>**----- End of picture text -----**<br> - ※De-rating is needed under low input voltage. ## **TOTAL HARMONIC DISTORTION (THD)** ## **EFFICIENCY vs LOAD** PWM-60 series possess superior working efficiency that up to 90% can be reached in field applications. ※ 48V Model, Tcase at 75℃ **==> picture [244 x 134] intentionally omitted <==** **----- Start of picture text -----**<br> 20%<br>18%<br>16%<br>14%<br>277VAC<br>12%<br>10% 230VAC<br>8% 115VAC<br>6%<br>4%<br>2%<br>0%<br>50% 60% 70% 80% 90% 100%<br>LOAD<br>THD<br>**----- End of picture text -----**<br> ※ 48V Model, Tcase at 75℃ **==> picture [243 x 128] intentionally omitted <==** **----- Start of picture text -----**<br> 92%<br>90%<br>88%<br>86% 277V<br>230V<br>84% 115V<br>82%<br>80%<br>78%<br>10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>LOAD<br>EFFICIENCY(%)<br>**----- End of picture text -----**<br> _File Name:PWM-60-SPEC 2019-01-10_ **- PWM 60 series** 60W PWM Output LED Driver ## **LIFE TIME** **==> picture [361 x 192] intentionally omitted <==** **----- Start of picture text -----**<br> 120<br>100<br>80<br>60<br>40<br>20<br>0<br>25 35 45 55 65 75 85<br>(Kh)<br>LIFETIME<br>**----- End of picture text -----**<br> **==> picture [43 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> Tc�����������℃<br>**----- End of picture text -----**<br> _File Name:PWM-60-SPEC 2019-01-10_ **- PWM 60 series** ## 60W PWM Output LED Driver ## **Block Diagram** **==> picture [507 x 487] intentionally omitted <==** **----- Start of picture text -----**<br> PFC fosc : 50~120KHz<br>PWM fosc : 60~130KHz<br>EMI FILTER PFC POWER RECTIFIERS Vo+<br>I/P & CIRCUIT SWITCHING & DIMMING Vo-<br>RECTIFIERS FILTER CIRCUIT<br>O.L.P. DIM+<br>DIM-<br>O.T.P. O.L.P. DETECTION<br>PWM & PFC CIRCUIT<br>CONTROL<br>O.V.P.<br>Mechanical Specification<br>Case No. NPF-60A Unit:mm<br>150<br>5<br>300±20<br>AC/L(Brown) 300±20<br>AC/N(Blue) Vo+(Red)<br>SJTW 18AWG×2C ψ4.5 tc 35 UL2464 18AWG×2C(Vo+,Vo-) DIM+(Blue)Vo-(Black)DIM-(White)***<br>UL2464 22AWG×2C(DIM+,DIM-)<br>5 * DIM+ for Blank-Type<br> DA+ for DA-type<br>* *DIM- for Blank-Type<br>‧ : Max. Case Temperaturetc DA- for DA-type<br>NOTE: DA Type is no distinction<br>between “+” and “-” poles<br>Recommend Mounting Direction<br>5<br>53<br>5 31<br>35<br>**----- End of picture text -----**<br> _File Name:PWM-60-SPEC 2019-01-10_ **- PWM 60 series** 60W PWM Output LED Driver ## **Installation Manual** ## ◎ **Connection for Blank-type** **==> picture [448 x 92] intentionally omitted <==** **----- Start of picture text -----**<br> Vo+(RED) +<br>AC/L(BROWN) LED Strip<br>-<br>Vo-(BLACK)<br>AC/N(BLUE)<br>DIM+(BLUE)<br>+<br>0~10Vdc or 10V PWM<br>- or resistance Dimmer<br>DIM-(WHITE) or DALI Dimmer<br>**----- End of picture text -----**<br> ## ◎ **Cautions** - ‧ Before commencing any installation or maintenance work, please disconnect the power supply from the utility. Ensure - that it cannot be re-connected inadvertently! - ‧Keep proper ventilation around the unit and do not stack any object on it. Also a 10-15 cm clearance must be kept when the adjacent device is a heat source. - ‧Mounting orientations other than standard orientation or operate under high ambient temperature may increase the internal component temperature and will require a de-rating in output current. - ‧ Current rating of an approved primary /secondary cable should be greater than or equal to that of the unit. Please refer - to its specification. - ‧ For LED drivers with waterproof connectors, verify that the linkage between the unit and the lighting fixture is - tight so that water cannot intrude into the system. - ‧ For dimmable LED drivers, make sure that your dimming controller is capable of driving these units.PWM series - require 0.15mA each unit. - ‧ Tc max. is identified on the product label. Please make sure that temperature of Tc point will not exceed limit. - DO NOT connect "DIM- to Vo-". - ‧ - ‧ Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 - minutes. - ‧ The power supply is considered as a component that will be operated in combination with final equipment. Since EMC - performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. - ‧For more information about installation, Please refer to : http://www.meanwell.com/manual.html for details. _File Name:PWM-60-SPEC 2019-01-10_
Updated at April 17, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →