PTP33B-GR7M1PGBWSJ
Pressure Switch, 4-20mA (4-Wire), IO-Link, Gauge, BSPP, -1 bar, 10 bar, PNP
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: ENDRESS+HAUSER
- Product type: Pressure Switches
- SVHC: No SVHC (27-Jun-2024)
- Deadband Max: -
- Deadband Min: -
- Pressure Type: Gauge
- Product Range: Ceraphant PTP33B Series
- Pressure Port Size: G1A
- Pressure Port Type: BSPP
- Contact Configuration: PNP
- Switching Current Max: 200mA
- Switching Voltage Max: -
- Operating Pressure Max: 10bar
- Operating Pressure Min: -1bar
- Operating Temperature Max: 70°C
- Operating Temperature Min: -40°C
- Transducer Connection / Termination: 4 Pin M12 Connector
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 323.36 € |
| Current stock | 10+ |
| Lead time | 30 days |
TI01246P/00/EN/06.18 71422363 2018-12-20
Products
Solutions
Services
## Technical Information Ceraphant PTP33B
Process pressure measurement
Pressure switch for safe measurement and monitoring of absolute and gauge pressure
## Application
The Ceraphant is a pressure switch for the measurement of absolute and gauge pressure in gases, vapors, liquids and dust for applications with hygienic requirements. The Ceraphant can be used internationally thanks to a wide range of approvals and process connections.
## Your benefits
- High reproducibility and long-term stability
- Reference accuracy: up to 0.3%
- Customized measuring ranges
- Turn down up to 5:1
- Sensor for measuring ranges up to 40 bar (600 psi)
- Housing and process isolating diaphragm made of 316L
- Fully-welded process connections
- Suitable for CIP/SIP cleaning
- Optionally available with IO-Link
Operation and electrical connection in accordance with VDMA 24574-1:2008
Ceraphant PTP33B
## Table of contents
|Document information . . . . . . . . . . . . . . . . . . . . . . .|4|
|---|---|
|Document function . . . . . . . . . . . . . . . . . . . . . . . . . . . .|4|
|Symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|4|
|Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|5|
|Terms and abbreviations . . . . . . . . . . . . . . . . . . . . . . . .|6|
|Turn down calculation . . . . . . . . . . . . . . . . . . . . . . . . . .|7|
|Function and system design . . . . . . . . . . . . . . . . . . .|8|
|Measuring principle - process pressure measurement . . . . .|8|
|Measuring system . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|8|
|Device features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|8|
|Product design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|10|
|System integration . . . . . . . . . . . . . . . . . . . . . . . . . . .|10|
|Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|11|
|Measured variable . . . . . . . . . . . . . . . . . . . . . . . . . . . .|11|
|Measuring range. . . . . . . . . . . . . . . . . . . . . . . . . . . .|11|
|Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>Output signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>Range of adjustment . . . . . . . . . . . . . . . . . . . . . . . . . .<br>Switching capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . .|12<br>12<br>12<br> 12|
|Signal range 4 to 20 mA . . . . . . . . . . . . . . . . . . . . . . . .|12|
|Load (for devices with analog output) . . . . . . . . . . . . . . .|12|
|Signal on alarm 4 to 20 mA . . . . . . . . . . . . . . . . . . . . . .|13|
|Dead time, time constant . . . . . . . . . . . . . . . . . . . . . . .|13|
|Dynamic behavior . . . . . . . . . . . . . . . . . . . . . . . . . . . .|13|
|Dynamic behavior of switch output . . . . . . . . . . . . . . . . .|14|
|Damping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|14|
|Power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|15|
|Terminal assignment . . . . . . . . . . . . . . . . . . . . . . . . . .|15|
|Supply voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|16|
|Current consumption and alarm signal . . . . . . . . . . . . . .|16|
|Power supply fault . . . . . . . . . . . . . . . . . . . . . . . . . . . .|16|
|Electrical connection . . . . . . . . . . . . . . . . . . . . . . . . . .|16|
|Cable specification . . . . . . . . . . . . . . . . . . . . . . . . . . . .|17|
|Residual ripple . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|17|
|Influence of power supply . . . . . . . . . . . . . . . . . . . . . . .|17|
|Overvoltage protection. . . . . . . . . . . . . . . . . . . . . . . .|17|
## Performance characteristics of metal process
|Performance characteristics of metal process||
|---|---|
|isolating diaphragm . . . . . . . . . . . . . . . . . . . . . . . .|18|
|Reference operating conditions . . . . . . . . . . . . . . . . . . .|18|
|Measuring uncertainty for small absolute pressure||
|measuring ranges . . . . . . . . . . . . . . . . . . . . . . . . . . . .|18|
|Influence of the installation position . . . . . . . . . . . . . . . .|18|
|Resolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>Reference accuracy . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>Thermal change of the zero output and the output span. . . <br>Long-term stability. . . . . . . . . . . . . . . . . . . . . . . . . . .|18<br>18<br> 18<br>18|
|Switch-on time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|18|
|Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|19|
|Installation conditions . . . . . . . . . . . . . . . . . . . . . . . . .<br>Influence of the installation position . . . . . . . . . . . . . . . .<br>Mounting location . . . . . . . . . . . . . . . . . . . . . . . . . . . .|19<br>19<br> 19|
|Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|22|
|---|---|
|Ambient temperature range . . . . . . . . . . . . . . . . . . . . .|22|
|Storage temperature range . . . . . . . . . . . . . . . . . . . . . .|22|
|Climate class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|22|
|Degree of protection . . . . . . . . . . . . . . . . . . . . . . . . . .|22|
|Vibration resistance . . . . . . . . . . . . . . . . . . . . . . . . . . .|22|
|Electromagnetic compatibility . . . . . . . . . . . . . . . . . . . .|22|
|Process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|23|
|Process temperature range for devices with metallic||
|process isolating diaphragm. . . . . . . . . . . . . . . . . . . . .|23|
|Pressure specifications . . . . . . . . . . . . . . . . . . . . . . . . .|23|
|Mechanical construction . . . . . . . . . . . . . . . . . . . .|24|
|Design, dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .|24|
|Electrical connection . . . . . . . . . . . . . . . . . . . . . . . . . .|24|
|Housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|25|
|Process connections with flush-mounted, metal process||
|isolating diaphragm . . . . . . . . . . . . . . . . . . . . . . . . . . .|26|
|Materials in contact with process . . . . . . . . . . . . . . . . . .|30|
|Materials not in contact with process . . . . . . . . . . . . . . .|31|
|Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|31|
|Operability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|32|
|IO-Link (optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . .|32|
|Operation with local display . . . . . . . . . . . . . . . . . . . . .|32|
|Device Search (IO-Link) . . . . . . . . . . . . . . . . . . . . . . . .|33|
|Functions of switch output . . . . . . . . . . . . . . . . . . . . . .|34|
|Certificates and approvals . . . . . . . . . . . . . . . . . . .|36|
|CE mark . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|36|
|RoHS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|36|
|RCM-Tick marking . . . . . . . . . . . . . . . . . . . . . . . . . . . .|36|
|Suitability for hygienic processes . . . . . . . . . . . . . . . . . .|36|
|Pressure Equipment Directive 2014/68/EU (PED) . . . . . . .|36|
|Manufacturer declarations . . . . . . . . . . . . . . . . . . . . . .|37|
|Other standards and guidelines . . . . . . . . . . . . . . . . . . .|37|
|CRN approval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|38|
|Calibration unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|38|
|Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|38|
|Inspection certificates . . . . . . . . . . . . . . . . . . . . . . . . . .|38|
|Additional approval . . . . . . . . . . . . . . . . . . . . . . . . . . .|39|
|Ordering information . . . . . . . . . . . . . . . . . . . . . . .|39|
|Scope of delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|39|
|Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|40|
|Weld-in adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|40|
|Process adapter M24 . . . . . . . . . . . . . . . . . . . . . . . . . .|40|
|M12 plug connectors . . . . . . . . . . . . . . . . . . . . . . . . . .|41|
|Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . .|42|
|Field of Activities . . . . . . . . . . . . . . . . . . . . . . . . . . . .|42|
|Technical Information . . . . . . . . . . . . . . . . . . . . . . . . .|42|
|Operating Instructions . . . . . . . . . . . . . . . . . . . . . . . . .|42|
|Brief Operating Instructions . . . . . . . . . . . . . . . . . . . . .|42|
Endress+Hauser
2
Ceraphant PTP33B
Registered trademarks . . . . . . . . . . . . . . . . . . . . . . 42
Endress+Hauser
3
Ceraphant PTP33B
## Document information
Document function
Symbols used
The document contains all the technical data on the device and provides an overview of the accessories and other products that can be ordered for the device.
## Safety symbols
|Symbol|Meaning|
|---|---|
|**DANGER**|DANGER!<br>This symbol alerts you to a dangerous situation. Failure to avoid this situation will result in<br>serious or fatal injury.|
|**WARNING**|WARNING!<br>This symbol alerts you to a dangerous situation. Failure to avoid this situation can result in<br>serious or fatal injury.|
|**CAUTION**|CAUTION!<br>This symbol alerts you to a dangerous situation. Failure to avoid this situation can result in<br>minor or medium injury.|
|**NOTICE**|NOTICE!<br>This symbol contains information on procedures and other facts which do not result in<br>personal injury.|
Electrical symbols
|Symbol|Meaning|Symbol|Meaning|
|---|---|---|---|
||Protective ground connection<br>A terminal which must be connected<br>to ground prior to establishing any<br>other connections.||Ground connection<br>A grounded terminal which, as far as<br>the operator is concerned, is<br>grounded via a grounding system.|
Symbols for certain types of information
|Symbol|Meaning|
|---|---|
||Permitted<br>Procedures, processes or actions that are permitted.|
||Forbidden<br>Procedures, processes or actions that are forbidden.|
||Tip<br>Indicates additional information.|
||Reference to documentation|
|**A**|Reference to page|
||Reference to graphic|
||Visual inspection|
## Symbols in graphics
|Symbol|Meaning|
|---|---|
|1, 2, 3 ...|Item numbers|
|,<br>…<br>,<br>1. 2. 3.|Series of steps|
|A, B, C, ...|Views|
Endress+Hauser
4
Ceraphant PTP33B
## Documentation
The document types listed are available: In the Download Area of the Endress+Hauser Internet site: www.endress.com → Download
Brief Operating Instructions (KA): getting the 1st measured value quickly Devices with IO-Link: KA01404P
These instructions contain all the essential information from incoming acceptance to initial commissioning (not for devices with IO-Link).
Operating Instructions (BA): your comprehensive reference
These Operating Instructions contain all the information that is required in various phases of the life cycle of the device: from product identification, incoming acceptance and storage, to mounting, connection, operation and commissioning through to troubleshooting, maintenance and disposal.
Endress+Hauser
5
Ceraphant PTP33B
## Terms and abbreviations
|URL<br>OPL<br>MWP<br>LRL<br>0<br>p<br>LRV<br>URV<br>1<br>2<br>3<br>4|URL<br>OPL<br>MWP<br>LRL<br>0<br>p<br>LRV<br>URV<br>1<br>2<br>3<br>4|URL<br>OPL<br>MWP<br>LRL<br>0<br>p<br>LRV<br>URV<br>1<br>2<br>3<br>4|
|---|---|---|
|A0029505|||
|Item|Term/<br>abbreviation|Explanation|
|1|OPL|The OPL (over pressure limit = sensor overload limit) for the measuring device<br>depends on the lowest-rated element, with regard to pressure, of the selected<br>components, i.e. the process connection has to be taken into consideration in<br>addition to the measuring cell. Also observe pressure-temperature dependency. For<br>the relevant standards and additional notes, see the "Pressure specifications" section<br>→ 23 .<br>The OPL may only be applied for a limited period of time.|
|2|MWP|The MWP (maximum working pressure) for the sensors depends on the lowest-<br>rated element, with regard to pressure, of the selected components, i.e. the process<br>connection has to be taken into consideration in addition to the measuring cell.<br>Also observe pressure-temperature dependency. For the relevant standards and<br>additional notes, see the "Pressure specifications" section → 23 .<br>The MWP may be applied at the device for an unlimited period.<br>The MWP can also be found on the nameplate.|
|3|Maximum sensor<br>measuring range|Span between LRL and URL<br>This sensor measuring range is equivalent to the maximum calibratable/adjustable<br>span.|
|4|Calibrated/adjusted<br>span|Span between LRV and URV<br>Factory setting: 0 to URL<br>Other calibrated spans can be ordered as customized spans.|
|p|-|Pressure|
|-|LRL|Lower range limit|
|-|URL|Upper range limit|
|-|LRV|Lower range value|
|-|URV|Upper range value|
|-|TD (turn down)|Turn down<br>Example - see the following section.|
Endress+Hauser
6
Ceraphant PTP33B
## Turn down calculation
1 = 2 3 LRL LRV URV URL _1 Calibrated/adjusted span 2 Zero point-based span 3 URL sensor_
**==> picture [22 x 4] intentionally omitted <==**
**----- Start of picture text -----**<br>
A0029545<br>**----- End of picture text -----**<br>
Example • Sensor:10 bar (150 psi) • Calibrated/adjusted span: 0 to 5 bar (0 to 75 psi) • Upper range value (URL) = 10 bar (150 psi) • Lower range value (LRV) = 0 bar (0 psi) • Upper range value (URV) = 5 bar (75 psi) Turn down (TD): URL TD = |URV - LRV| 10 bar (150 psi) TD = = 2 - |5 bar (75 psi) 0 bar (0 psi)| In this example, the TD is 2:1. This span is based on the zero point.
Endress+Hauser
7
Ceraphant PTP33B
## Function and system design
## Measuring principle - process pressure measurement
Devices with metallic process isolating diaphragm
The process pressure deflects the metal process isolating diaphragm of the sensor and a fill fluid transfers the pressure to a Wheatstone bridge (semiconductor technology). The pressure-dependent change in the bridge output voltage is measured and evaluated.
## Advantages:
- Can be used for high process pressures
- Fully welded sensor
- Slim, flush-mounted process connections available
**==> picture [319 x 116] intentionally omitted <==**
**----- Start of picture text -----**<br>
1<br>2<br>3<br>4<br>p<br>**----- End of picture text -----**<br>
**==> picture [22 x 4] intentionally omitted <==**
**----- Start of picture text -----**<br>
A0016448<br>**----- End of picture text -----**<br>
- _1 Silicon measuring element, substrate_
- _2 Wheatstone bridge_
- _3 Channel with fill fluid_
- _4 Metal process isolating diaphragm_
## Measuring system
A complete measuring system comprises:
**==> picture [71 x 54] intentionally omitted <==**
**==> picture [171 x 56] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 2 3<br>**----- End of picture text -----**<br>
**==> picture [22 x 4] intentionally omitted <==**
**----- Start of picture text -----**<br>
A0021924<br>**----- End of picture text -----**<br>
- _1 PLC (programmable logic control)_
- _2 e.g. RMA42 / RIA45 (if required)_
- _3 Device_
Device features
## Field of application
PTP33B: Gauge and absolute pressure and hygienic applications
## Process connections
PTP33B:
- Thread ISO 228
- Thread M24 x 1.5
- SMS
- Varivent
- Clamp/Tri-Clamp
- DIN 11851
## Measuring ranges
PTP33B: from 0 to +400 mbar (0 to +6 psi) to 0 to +40 bar (0 to +600 psi).
OPL (depends on the measuring range)
PTP33B: max. 0 to +160 bar (0 to +2 400 psi)
Endress+Hauser
8
Ceraphant PTP33B
## MWP
PTP33B: max. 0 to +100 bar (0 to +1 500 psi)
Process temperature range (temperature at process connection)
PTP33B: –10 to +100 °C (+14 to +212 °F) (+135 °C (+275 °F) for one hour maximum)
## Ambient temperature range
PTP33B: –40 to +70 °C (–40 to +158 °F)(in the range of the temperature limits with restrictions in optical properties, such as display speed and contrast)
## Reference accuracy
PTP33B: standard: up to 0.5 %; platinum: up to 0.3 %
## Supply voltage
PTP33B: 10 to 30 V DC at a DC power unit
PTP33B IO-Link: 10 to 30 V DC at a DC power unit
IO-Link communication is guaranteed only if the supply voltage is at least 18 V.
## Output
Devices with IO-Link: c/Q output for communication (SIO mode (switch output))
PTP33B:
- 1 x PNP switch output (three-wire) (not with IO-Link)
- 2 x PNP switch output (four-wire), IO-Link
- 1 x PNP switch output + 4 to 20 mA output (four-wire), IO-Link
## Material
PTP33B:
- Housing made from 316L (1.4404)
- Process connections made from 316L (1.4435)
- Process isolating diaphragm made from 316L (1.4435)
## Options
PTP33B:
- 3.1 Material certificates
- EHEDG/3A approvals
- Certificate of calibration
- Weld-in adapter
- Min. alarm current setting
- IO-Link
Endress+Hauser
9
Ceraphant PTP33B
## Product design
**==> picture [517 x 238] intentionally omitted <==**
**----- Start of picture text -----**<br>
Overview Item Description<br>A B C A Valve plug<br>B Cable<br>C M12 plug<br>Housing cap made of plastic<br> A0022015 A0037236<br> A0037238<br>D D Housing<br>E Process connection (sample illustration)<br>E<br> A0027227<br>**----- End of picture text -----**<br>
System integration
The device can be given a tag name (max. 32 alphanumeric characters).
|Designation|Option1)|
|---|---|
|Measuring point (TAG), see additional specifications|Z1|
- 1) Product Configurator order code for "Marking"
For devices with IO-Link, an IO-DD is available in the Downloads area of the Endress+Hauser website → 32.
Endress+Hauser
10
Ceraphant PTP33B
## Input
|||Input|Input|Input|Input|Input|Input|Input|
|---|---|---|---|---|---|---|---|---|
|Measured variable||Measured process variable<br>Gauge pressure or absolute pressure<br>Calculated process variable<br>Pressure|||||||
|Measuring range||Metal process isolating diaphragm|||||||
|Sensor|Device|Maximum<br>Sensor measuring range||Lowest<br>calibratable<br>1)|MWP|OPL|Factory settings2)|Option3)|
|||lower (LRL)|upper (URL)|span|||||
|||[bar (psi)]|[bar (psi)]|[bar (psi)]|[bar (psi)]|[bar (psi)]|||
|Devices for gauge pressure measurement|||||||||
|400 mbar (6 psi)4)|PTP33B|–0.4 (–6)|+0.4 (+6)|0.4 (6)|1 (15)|1.6 (24)|0 to 400 mbar (0 to 6 psi)|1F|
|1 bar (15 psi)4)|PTP33B|–1 (–15)|+1 (+15)|0.4 (6)|2.7 (40.5)|4 (60)|0 to 1 bar (0 to 15 psi)|1H|
|2 bar (30 psi)4)|PTP33B|–1 (–15)|+2 (+30)|0.4 (6)|6.7 (100.5)|10 (150)|0 to 2 bar (0 to 30 psi)|1K|
|4 bar (60 psi)4)|PTP33B|–1 (–15)|+4 (+60)|0.8 (12)|10.7 (160.5)|16 (240)|0 to 4 bar (0 to 60 psi)|1M|
|10 bar (150 psi)4)|PTP33B|–1 (–15)|+10 (+150)|2 (30)|25 (375)|40 (600)|0 to 10 bar (0 to 150 psi)|1P|
|40 bar (600 psi)4)|PTP33B|–1 (–15)|+40 (+600)|8 (120)|100 (1500)|160 (2400)|0 to 40 bar (0 to 600 psi)|1S|
|Devices for absolute pressure measurement|||||||||
|400 mbar (6 psi)4)|PTP33B|0 (0)|0.4 (+6)|0.4 (6)|1 (15)|1.6 (24)|0 to 400 mbar (0 to 6 psi)|2F|
|1 bar (15 psi)4)|PTP33B|0 (0)|1 (+15)|0.4 (6)|2.7 (40.5)|4 (60)|0 to 1 bar (0 to 15 psi)|2H|
|2 bar (30 psi)4)|PTP33B|0 (0)|2 (+30)|0.4 (6)|6.7 (100.5)|10 (150)|0 to 2 bar (0 to 30 psi)|2K|
|4 bar (60 psi)4)|PTP33B|0 (0)|4 (+60)|0.8 (12)|10.7 (160.5)|16 (240)|0 to 4 bar (0 to 60 psi)|2M|
|10 bar (150 psi)4)|PTP33B|0 (0)|10 (+150)|2 (30)|25 (375)|40 (600)|0 to 10 bar (0 to 150 psi)|2P|
|40 bar (600 psi)4)|PTP33B|0 (0)|+40 (+600)|8 (120)|100 (1500)|160 (2400)|0 to 40 bar (0 to 600 psi)|2S|
1) Highest turn down that can be set at the factory: 5:1. The turn down is preset and cannot be changed.
2) Other measuring ranges (e.g. –1 to +5 bar (–15 to 75 psi)) can be ordered with customer-specific settings (see the Product Configurator, order code for "Calibration; Unit" option "U"). It is possible to invert the output signal (LRV = 20 mA; URV = 4 mA). Prerequisite: URV < LRV
3) Product Configurator, order code for "Sensor range"
4) Vacuum resistance: 0.01 bar (0.145 psi) abs
_Maximum turn down which can be ordered for absolute pressure and gauge pressure sensors_
Ranges 0.5%/0.3%: TD 1:1 to TD 5:1
Endress+Hauser
11
Ceraphant PTP33B
||Output|Output|
|---|---|---|
|Output signal|Designation|Option1)|
||PNP switch output + 4 to 20 mA output (4-wire), IO-Link|7|
||PNP switch output (3-wire)|4|
||2 x PNP switch output (4-wire), IO-Link|8|
||1)<br>Product Configurator, order code for "Output"||
- Range of adjustment • Switch output
Switch point (SP): 0.5 to 100 % in increments of 0.1% (min. 1 mbar * (0.015 psi)) of the upper range limit (URL) switchback point (RSP): 0 to 99.5% in increments of 0.1% (min. 1 mbar * (0.015 psi)) of the upper range limit (URL) Minimum distance between SP and RSP: 0.5 % URL
- Analog output (if available) Lower range value (LRV) and upper range value (URV) can be set anywhere within the sensor range (LRL - URL). Turn down for analog output up to 5:1 of upper sensor limit (URL).
- Factory setting (if no customer-specific setting is ordered): Switch point SP1: 90 %; switchback point RP1: 10 %; Switch point SP2: 95 %; switchback point RP2: 15 %; Analog output: LRV 0 %; URV 100 %
- For measuring ranges with a negative gauge pressure up to 4 bar (60 psi), the increment when setting the switch point is min. 10 mbar (0.15 psi)
- Switching capacity • Switch state ON: Ia ≤ 250 mA; switch state OFF: Ia ≤1 mA • Devices with IO-Link: Switch state ON[ 1)] : Ia ≤ 200 mA[ 2)] ; switch state OFF: Ia ≤100 μA • Switch cycles: >10,000,000 • Voltage drop PNP: ≤2 V • Overload protection: Automatic load testing of switching current; – Max. capacitive load: 14 μF at max. supply voltage (without resistive load)
- – Devices with IO-Link: Max. capacitive load: 1 μF at max. supply voltage (without resistive load)
- – Max. cycle duration: 0.5 s; min. ton: 4 mson: 4 ms: 4 ms – Max. cycle duration: 0.5 s; min. ton: 40 μs – Periodic disconnection from protective circuit in the event of overcurrent (f = 2 Hz) and "F804" displayed
- Signal range 4 to 20 mA 3.8 mA to 20.5 mA
- Overload protection: Automatic load testing of switching current; – Max. capacitive load: 14 μF at max. supply voltage (without resistive load)
- – Devices with IO-Link: Max. capacitive load: 1 μF at max. supply voltage (without resistive load)
- – Max. cycle duration: 0.5 s; min. ton: 4 mson: 4 ms: 4 ms
Load (for devices with analog In order to guarantee sufficient terminal voltage, a maximum load resistance RL (including line output) resistance) must not be exceeded depending on the supply voltage UB of the supply unit.
The maximum load resistance depends on the terminal voltage and is calculated according to the following formula:
> 1) 100 mA can be guaranteed over the entire temperature range for the switch outputs "2 x PNP" and "1 x PNP + 4 to 20 mA output". For lower ambient temperatures, higher currents are possible but cannot be guaranteed. Typical value at 20 °C (68 °F) approx. 200 mA. 200 mA can be guaranteed over the entire temperature range for the "1 x PNP" current output.
> 2) Larger currents are supported, thus deviating from the IO-Link standard.
Endress+Hauser
12
Ceraphant PTP33B
**==> picture [387 x 159] intentionally omitted <==**
**----- Start of picture text -----**<br>
RLmax<br>[�]<br>1022<br>587 2 RLmax � U B � 6.5V<br>23mA<br>152<br>0 10 20 30 UB<br>1 [V]<br> A0031107<br>**----- End of picture text -----**<br>
- _1 Power supply 10 to 30 V DC_
- _2 RLmax maximum load resistance UB Supply voltage_
## If load is too great:
- failure current is output and "S803" displayed (output: MIN alarm current)
- Periodic checking to establish if it is possible to quit fault state
- In order to guarantee sufficient terminal voltage, a maximum load resistance RL (including line resistance) must not be exceeded depending on the supply voltage UB of the supply unit.
## Signal on alarm 4 to 20 mA
The response of the output to error is regulated in accordance with NAMUR NE43.
- The behavior of the current output in the event of faults is defined in the following parameters: • Alarm current FCU "MIN": Lower alarm current (≤3.6 mA) (optional, see the following table)
- Alarm current FCU "MAX" (factory setting): Upper alarm current (≥21 mA)
- Alarm current FCU "HLD" (HOLD) (optional, see the following table): Last measured current value is held. When the device starts, the current output is set to "Lower alarm current" (≤3.6 mA).
## alarm current
|Device|Description|Option|
|---|---|---|
|PTP33B|Adjusted min. alarm current|IA1)|
|PTP33B|1 low ≤3.6 mA<br>2 high ≥21 mA<br>3 last current value|U2)|
|1)<br>Product Configurator order code for "Service"<br>2)<br>Product Configurator order code for "Calibration/unit"|||
Dead time, time constant Presentation of the dead time and the time constant:
**==> picture [387 x 126] intentionally omitted <==**
**----- Start of picture text -----**<br>
I<br>100 %<br>90 %<br>63 %<br>t1 t2 t<br>t3<br> A0019786<br>**----- End of picture text -----**<br>
Dynamic behavior
Endress+Hauser
13
Ceraphant PTP33B
## Analog electronics
|Dead time (t1) [ms]|Time constant (T63), t2[ms]|Time constant (T90), t3[ms]|
|---|---|---|
|7 ms|11 ms|16 ms|
Dynamic behavior of switch output
Damping
PNP switch output and 2 x PNP switch output: response time ≤20 ms
Once the supply voltage has been applied, damping for the first measured value is at 0 i.e. the first measured value applied always corresponds to the actual measured value (regardless of damping). A damping affects all outputs (output signal, display):
- Via local display, infinitely variable 0 to 999.9 s
- Factory setting: 2.0 s
Endress+Hauser
14
Ceraphant PTP33B
## Power supply
## L[WARNING]
## Electrical safety is compromised by an incorrect connection!
- ‣ In accordance with IEC/EN61010 a separate circuit breaker must be provided for the device .
- ‣ Protective circuits against reverse polarity, HF influences and overvoltage peaks are integrated. ‣ The device must be operated with a 630 mA fine-wire fuse (slow-blow).
## Terminal assignment
## _1 x PNP switch output R1 (not with IO-Link functionality)_
**==> picture [387 x 172] intentionally omitted <==**
**----- Start of picture text -----**<br>
M12 plug Valve plug Cable<br>0.63A 0.63A 1 0.63A<br>L+ 1 L+ L+<br>2 1 2a<br>3<br>3 4 R1 4 � R1<br>L– R1 3 L–<br> A0029268 2 L– 4 �<br> A0023271 2b (a)<br> A0022801<br>1 brown = L+<br>2a black = switch output 1<br>2b white = not in use<br>3 blue = L-<br>4 green/yellow = ground<br>(a) reference air hose<br>**----- End of picture text -----**<br>
## _2 x PNP switch output R1 and R2_
**==> picture [387 x 172] intentionally omitted <==**
**----- Start of picture text -----**<br>
M12 plug Valve plug Cable<br>0.63A - 1 0.63A<br>L+ L+<br>2a<br>2 1<br>2b<br>3 4 R1 R1<br>R2<br>L– 3<br>L–<br>R2 4<br>�<br> A0023248 (a)<br> A0023282<br>1 brown = L+<br>2a black = switch output 1<br>2b white = switch output 2<br>3 blue = L-<br>4 green/yellow = ground<br>(a) reference air hose<br>**----- End of picture text -----**<br>
## _IO-Link: 2 x PNP switch output R1 and R2_
**==> picture [387 x 107] intentionally omitted <==**
**----- Start of picture text -----**<br>
M12 plug<br>0.63 A<br>L+<br>2 1<br>IO-Link<br>Q2 C/Q 1<br>3 4<br>SIO<br>L–<br>R1<br> A0036997<br>**----- End of picture text -----**<br>
Endress+Hauser
15
Ceraphant PTP33B
_1 x PNP switch output R1 with additional analog output 4 to 20 mA (active)_
**==> picture [387 x 176] intentionally omitted <==**
**----- Start of picture text -----**<br>
M12 plug Valve plug Cable<br>0.63A - 1 0.63A<br>L+ L+<br>2a<br>2 1<br>2b<br>3 4 R1 R1<br>L–<br>3<br>L–<br>4<br>�<br> A0023249 (a)<br> A0030519<br>1 brown = L+<br>2a black = switch output 1<br>2b white = analog output 4 to 20 mA<br>3 blue = L-<br>4 green/yellow = ground<br>(a) reference air hose<br>**----- End of picture text -----**<br>
_IO-Link: 1 x PNP switch output R1 with additional analog output 4 to 20 mA (active)_
**==> picture [387 x 89] intentionally omitted <==**
**----- Start of picture text -----**<br>
M12 plug<br>0.63 A<br>L+<br>2 1<br>IO-Link<br>C/Q<br>3 4<br>SIO<br>L–<br> A0036998<br>**----- End of picture text -----**<br>
## Supply voltage
Supply voltage: 10 to 30 V DC at a DC power unit
Supply voltage IO-Link: 10 to 30 V DC at a DC power unit
IO-Link communication is guaranteed only if the supply voltage is at least 18 V.
Current consumption and alarm signal
|Intrinsic power consumption|Alarm current (for devices with analog output)1)|
|---|---|
|≤ 60 mA|≥21 mA (factory setting)|
|Devices with IO-Link: Maximum current consumption: ≤ 300 mA||
- 1) Setting min. alarm current ≤3.6mA can be ordered via the product order structure. Min. alarm current ≤3.6mA can be configured at the device or via IO-Link.
Power supply fault
- Behavior in the event of overvoltage (>30 V): The device works continuously up to 34 V DC without damage. If the supply voltage is exceeded, the specified characteristics are no longer guaranteed.
- Behavior in the event of undervoltage:
If the supply voltage falls below the minimum value, the device switches off in a defined manner.
## Electrical connection
## Degree of protection
|Device|Connection|Degree of protection|Option1)|
|---|---|---|---|
|PTP33B|Cable5 m (16 ft)|IP66/67 NEMA type 4X enclosure|D|
|PTP33B|Cable10 m (33 ft)|IP66/67 NEMA type 4X enclosure|E|
|PTP33B|Cable25 m (82 ft)|IP66/67 NEMA type 4X enclosure|F|
|PTP33B|M12 plug|IP65/67 NEMA type 4X enclosure|M|
|PTP33B|Valve plug ISO4400 M16|IP65 NEMA type 4X enclosure|U|
|PTP33B|Valve plug ISO4400 NPT ½|IP65 NEMA type 4X enclosure|V|
- 1) Product Configurator order code for "Electrical connection"
Endress+Hauser
16
Ceraphant PTP33B
|Cable specification|For valve plug: < 1.5 mm2(16 AWG) and Ø4.5 to 10 mm (0.18 to 0.39 in)|
|---|---|
|Residual ripple|The device operates within the reference accuracy up to ±5 % of the residual ripple of the supply|
||voltage, within the permitted voltage range.|
|Influence of power supply|≤0.005 % of the URL/1 V|
|Overvoltage protection|The device does not contain any special elements to protect against overvoltage ("wire to ground").|
||Nevertheless the requirements of the applicable EMC standard EN 61000-4-5 (testing voltage 1kV|
||EMC wire/ground) are met.|
Endress+Hauser
17
Ceraphant PTP33B
## Performance characteristics of metal process isolating diaphragm
||Performance characteristics of metal process isolating<br>diaphragm|Performance characteristics of metal process isolating<br>diaphragm|Performance characteristics of metal process isolating<br>diaphragm|Performance characteristics of metal process isolating<br>diaphragm|
|---|---|---|---|---|
|Reference operating<br>conditions|• As per IEC 60770<br>• Ambient temperature TA= constant, in the range: +21 to +33 °C (+70 to +91 °F)<br>• Humidity φ = constant, in the range: 5 to 80 % rH<br>• Ambient pressure pA= constant, in the range: 860 to 1 060 mbar (12.47 to 15.37 psi)<br>• Position of measuring cell = constant, in the range: horizontal ±1° (see also "Influence of the<br>installation position" section → 19)<br>• Zero based span<br>• Process isolating diaphragm material: AISI 316L (1.4435)<br>• Filling oil: synthetic oil polyalphaolefin FDA 21 CFR 178.3620, NSF H1<br>• Supply voltage: 24 V DC ±3 V DC<br>• Load: 320 Ω (at 4 to 20 mA output)||||
|Measuring uncertainty for<br>small absolute pressure<br>measuring ranges|The smallest extended uncertainty of measurement that can delivered by our standards is:<br>• in the range 1 to 30 mbar (0.0145 to 0.435 psi): 0.4 % of reading<br>• in the range < 1 mbar (0.0145 psi): 1 % of reading.||||
|Influence of the installation<br>position|→ 19||||
|Resolution|Current output: min. 1.6 μA<br>Display: can be set (factory setting: presentation of the maximum accuracy of the transmitter)||||
|Reference accuracy|The reference accuracy contains the non-linearity [DIN EN 61298-2 3.11] including the pressure<br>hysteresis [DIN EN 61298-23.13] and non-repeatability [DIN EN 61298-2 3.11] in accordance with<br>the limit point method as per [DIN EN 60770].||||
||Device|% of the calibrated span to the maximum turn down|||
|||Reference accuracy|Non-linearity|Non-repeatability|
||PTP33B - standard|±0.5|±0.1|±0.1|
||PTP33B - platinum|±0.3|±0.1|±0.1|
Overview of the turn down ranges → 11
|Thermal change of the zero<br>output and the output span|Measuring cell|–20 to +85 °C (–4 to +185 °F)|–20 to +85 °C (–4 to +185 °F)|–20 to +85 °C (–4 to +185 °F)|–40 to –20 °C (–40 to –4 °F)<br>+85 to +100 °C (+185 to +212 °F)|–40 to –20 °C (–40 to –4 °F)<br>+85 to +100 °C (+185 to +212 °F)|
|---|---|---|---|---|---|---|
|||% of the calibrated span for TD 1:1|||||
||<1 bar (15 psi)|<1|||<1.2||
||≥ 1 bar (15 psi)|<0.8|||<1||
||||||||
|Long-term stability|Device||1 year|5 years||8 years|
||||% of URL||||
||PTP33B||±0.2|±0.4||In preparation|
||||||||
|Switch-on time|≤2 s||||||
The following applies for IO-Link: For small measuring ranges, pay attention to the thermal compensation effects.
Endress+Hauser
18
Ceraphant PTP33B
## Installation
## Installation conditions
- Moisture must not penetrate the housing when mounting the device, establishing the electrical connection and during operation.
- Point the cable and connector downwards where possible to prevent moisture from entering (e.g. rain or condensation water).
Influence of the installation position
Any orientation is possible. However, the orientation may cause a zero point shift i.e. the measured value does not show zero when the vessel is empty or partially full.
|**C**<br>**A**<br>**B**|**C**<br>**A**<br>**B**|**C**<br>**A**<br>**B**|**C**<br>**A**<br>**B**|
|---|---|---|---|
|A0024708||||
|Type|Process isolating diaphragm<br>axis is horizontal (A)|Process isolating diaphragm<br>pointing upwards (B)|Process isolating diaphragm<br>pointing downwards (C)|
|PTP33B|Calibration position, no effect|Up to +4 mbar (+0.058 psi)|Up to –4 mbar (–0.058 psi)|
A position-dependent zero shift can be corrected on the device .
## Mounting location
## Pressure measurement
## _Pressure measurement in gases_
Mount the device with shutoff device above the tapping point so that any condensate can flow into the process.
**==> picture [7 x 30] intentionally omitted <==**
**----- Start of picture text -----**<br>
1<br>2<br>**----- End of picture text -----**<br>
**==> picture [22 x 4] intentionally omitted <==**
**----- Start of picture text -----**<br>
A0025920<br>**----- End of picture text -----**<br>
- _1 Device_
- _2 Shutoff device_
## _Pressure measurement in vapors_
Advantage:
- defined water column causes only minor/negligible measuring errors and
- only minor/negligible heat effects on the device.
Mounting above the tapping point is also permitted.
Note the max. permitted ambient temperature of the transmitter!
Take the influence of the hydrostatic water column into consideration.
Endress+Hauser
19
Ceraphant PTP33B
**==> picture [55 x 128] intentionally omitted <==**
**==> picture [123 x 33] intentionally omitted <==**
**==> picture [172 x 114] intentionally omitted <==**
**----- Start of picture text -----**<br>
1<br>4<br>2<br>2<br>3<br>1<br>**----- End of picture text -----**<br>
**==> picture [22 x 4] intentionally omitted <==**
**----- Start of picture text -----**<br>
A0025921<br>**----- End of picture text -----**<br>
**==> picture [66 x 38] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 Device<br>2 Shutoff device<br>3 Siphon<br>4 Siphon<br>**----- End of picture text -----**<br>
## _Pressure measurement in liquids_
Mount the device with a shutoff device and siphon below or at the same height as the tapping point. Take the influence of the hydrostatic water column into consideration.
**==> picture [387 x 189] intentionally omitted <==**
**----- Start of picture text -----**<br>
1<br>2<br>3<br> A0025922<br>1 Device<br>2 Shutoff device<br>3 Siphon<br>**----- End of picture text -----**<br>
## Level measurement
- Always install the device below the lowest measuring point.
- Do not install the device at the following positions: – In the filling curtain
- In the tank outlet
- in the suction area of a pump
- Or at a point in the tank which could be affected by pressure pulses from the agitator.
- A functional test can be carried out more easily if you mount the device downstream from a shutoff device.
Endress+Hauser
20
Ceraphant PTP33B
**==> picture [330 x 132] intentionally omitted <==**
**==> picture [22 x 4] intentionally omitted <==**
**----- Start of picture text -----**<br>
A0025923<br>**----- End of picture text -----**<br>
Endress+Hauser
21
Ceraphant PTP33B
## Environment
|Ambient temperature range|Device|Ambient temperature range1)|Ambient temperature range1)|Ambient temperature range1)|Ambient temperature range1)|Ambient temperature range1)|Ambient temperature range1)|
|---|---|---|---|---|---|---|---|
||PTP33B|–20 to +70 °C (–4 to +158 °F)<br>IO-Link: –40 to +70 °C (–40 to +158 °F)<br>(in the range of the temperature limits with restrictions in optical properties, such as display speed<br>and contrast)||||||
||1)<br>Exception: the following cable is designed for an ambient temperature range of<br>–25 to +70 °C (–13 to +158 °F): Product Configurator order code for "Enclosed accessories" option "RZ".|||||||
|Storage temperature range|–40 to +85 °C (–40 to +185 °F)|||||||
|Climate class|Device||Climate class|Note||||
||PTP33B||Class 3K5|Air temperature: –5 to +45 °C (+23 to +113 °F),<br>relative humidity: 4 to 95 %<br>satisfied according to IEC 721-3-3 (condensation not possible)||||
|||||||||
|Degree of protection|Device||Connection|||Degree of protection|Option1)|
||PTP33B||Cable5 m (16 ft)|||IP66/67 NEMA type 4X enclosure|D|
||PTP33B||Cable10 m (33 ft)|||IP66/67 NEMA type 4X enclosure|E|
||PTP33B||Cable25 m (82 ft)|||IP66/67 NEMA type 4X enclosure|F|
||PTP33B||M12 plug|||IP65/67 NEMA type 4X enclosure|M|
||PTP33B||Valve plug ISO4400 M16|||IP65 NEMA type 4X enclosure|U|
||PTP33B||Valve plug ISO4400 NPT ½|||IP65 NEMA type 4X enclosure|V|
||1)<br>Product Configurator order code for "Electrical connection"|||||||
|Vibration resistance|Test standard||||Vibration resistance|||
||IEC 60068-2-64:2008||||Guaranteed for 5 to 2000Hz: 0.05g2/Hz|||
|||||||||
|Electromagnetic<br>compatibility|• Interference emission as per EN 61326-1 equipment B<br>• Interference immunity as per EN 61326-1 (industrial environment)|||||||
- Devices with IO-Link: For intended use, the switch output can switch to the communication mode for 0.2 s in the event of transient faults.
- NAMUR recommendation EMC (NE21) (not for devices with IO-Link)
- Maximum deviation: 1.5% with TD 1:1
For more details, please refer to the Declaration of Conformity.
Endress+Hauser
22
Ceraphant PTP33B
## Process
||Process||
|---|---|---|
|Process temperature range<br>for devices with metallic<br>process isolating diaphragm|Device|Process temperature range|
||PTP33B|–10 to +100 °C (+14 to +212 °F)|
||PTP33B<br>Sterilization in place (SIP)|At +135°C (+275 °F) for a maximum of one hour (device in operation but not within<br>measuring specification)|
Applications with changes in temperature Frequent extreme changes in temperatures can temporarily cause measuring errors. Internal temperature compensation is faster the smaller the change in temperature and the longer the time interval.
For further information please contact your local Endress+Hauser Sales Center.
## L[[WARNING]]
> Pressure specifications L[[WARNING]] The maximum pressure for the measuring device depends on the lowest-rated element with regard to pressure.
- ‣ For pressure specifications, see the "Measuring range" section and the "Mechanical construction" section.
- ‣ The Pressure Equipment Directive (2014/68/EU) uses the abbreviation "PS". The abbreviation "PS" corresponds to the MWP (maximum working pressure) of the measuring device.
- ‣ MWP (maximum working pressure): The MWP (maximum working pressure) is specified on the nameplate. This value is based on a reference temperature of +20 °C (+68 °F) and may be applied to the device for an unlimited period of time. Observe the temperature dependency of the MWP.
- ‣ OPL (over pressure limit): The test pressure corresponds to the over pressure limit of the sensor and may only be applied temporarily to ensure that the measurement is within the specifications and no permanent damage develops. In the case of sensor range and process connections where the over pressure limit (OPL) of the process connection is smaller than the nominal value of the sensor, the device is set at the factory, at the very maximum, to the OPL value of the process connection. If you want to use the entire sensor range, select a process connection with a higher OPL value.
Endress+Hauser
23
Ceraphant PTP33B
## Mechanical construction
For the dimensions, see the Product Configurator: www.endress.com
Search for product → click "Configuration" to the right of the product image → after configuration click "CAD"
The following dimensions are rounded values. For this reason, they may deviate slightly from the dimensions given on www.endress.com.
## Design, dimensions
## Device height
The device height is calculated from
- the height of the electrical connection
- the height of the housing and
- the height of the individual process connection.
The individual heights of the components are listed in the following sections. To calculate the device height simply add up the individual heights of the components. Where applicable also take into consideration the installation distance (space that is used to install the device). You can use the following table for this purpose:
|Section|Page|Height|Example|
|---|---|---|---|
|Electrical connection|→ 24|(A)|**A**<br>**B**<br>**C**<br>**D**<br>A0027267|
|Housing height|→ 25|(B)||
|Process connection height|→ 26|(C)||
|Installation distance|-|(D)||
## Electrical connection
|Electrical connection|Electrical connection||||||
|---|---|---|---|---|---|---|
|A<br>ø41 (1.61)<br>M12x1<br>56 (2.2)<br>A0022840||B<br>26 (1.02)<br>r�120 (4.72)<br>ø41 (1.61)<br>56 (2.2)<br>A0022842|||C<br>35 (1.38)<br>36 (1.42)<br>ø41 (1.61)<br>56 (2.2)<br>A0022836||
|Engineering unit mm (in)|||||||
||||||||
|Position|Designation||Material|Weight kg (lbs)||Option1)|
|A|M12 plug IP65/67<br>(Additional dimensions → 41)||Housing cap made of plastic|0.012 (0.03)||M<br>Plug connector with cable<br>can be ordered as an accessory → 41|
|B|Cable5 m (16 ft)||PUR (UL94V0)|0.280 (0.62)||D|
|B|Cable10 m (33 ft)||PUR (UL94V0)|0.570 (1.26)||E|
|B|Cable25 m (82 ft)||PUR (UL94V0)|1.400 (3.09)||F|
Endress+Hauser
24
Ceraphant PTP33B
|Position|Designation|Material|Weight kg (lbs)|Option1)|
|---|---|---|---|---|
|C|M16 valve plug|Plastic PPSU|0.060 (0.14)|U|
|C|NPT ½ valve plug|Plastic PPSU|0.060 (0.14)|V|
1) Product Configurator, order code for "Electrical connection"
Housing
**==> picture [387 x 271] intentionally omitted <==**
**----- Start of picture text -----**<br>
ø31.5 (1.24)<br> A0025964<br>Engineering unit mm (in)<br>Device Material Weight kg (lbs)<br>PTP33B Stainless steel 316L 0.100 (0.22)<br>60 (2.36)<br>**----- End of picture text -----**<br>
Endress+Hauser
25
Ceraphant PTP33B
Process connections with flush-mounted, metal process isolating diaphragm Thread ISO 228 G
**==> picture [517 x 199] intentionally omitted <==**
**----- Start of picture text -----**<br>
A B<br>36 36<br>ø25.4 (1) ø29 (1.14)<br>ø30 (1.18) G 1" A<br>G 1" A ø39 (1.54)<br> A0021972 A0021973<br>Engineering unit mm (in). Diameter of process isolating diaphragm: 17.2 mm (0.68 in)<br>7 (0.28)<br>48 (1.89) 48 (1.89)<br>7 (0.28)<br>26.8 (1.06) 29.5 (1.16)<br>22.3 (0.88) 8.8 (0.35) 10.9 (0.43)<br>**----- End of picture text -----**<br>
|Item|Description|Seal|Material|Weight<br>|Approval|Option1)|
|---|---|---|---|---|---|---|
|||||kg (lbs)|||
|A|Thread ISO 228 G 1" A|Metal joint|316L|0.270 (0.60)<br>|CRN|WQJ|
|B|Thread ISO 228 G 1" A|Seal established via O-ring.<br>VMQ O-ring is enclosed with QJ and QK accessories.|316L|0.270 (0.60)<br>|EHEDG, 3A2), CRN|WSJ|
1) Product Configurator, order code for "Process connection"
- 2) EHEDG and 3A only in conjunction with weld-in adapter → 40
Endress+Hauser
26
Ceraphant PTP33B
## Thread M24 x 1.5
**==> picture [303 x 181] intentionally omitted <==**
**----- Start of picture text -----**<br>
ø24 (0.94)<br>32<br>M24x1.5<br>2 ø31.5 (1.24)<br> A0021969<br>7 (0.28)<br>41 (1.61)<br>4 (0.16)<br>13.8 (0.54) 17 (0.67)<br>**----- End of picture text -----**<br>
Engineering unit mm (in). Diameter of process isolating diaphragm: 17.2 mm (0.68 in)
|Designation|Seal|Material|Weight|Approval|Option1)|
|---|---|---|---|---|---|
||||kg (lbs)|||
|M24 x 1.52)|EPDM O-ring (2), pre-mounted|316L|0.150 (0.33)|EHEDG, 3A, CRN|X2J|
|M24 x 1.52)|FKM O-ring (2), pre-mounted|316L|0.150 (0.33)|EHEDG, 3A, CRN|X3J|
- 1) Product Configurator, order code for "Process connection"
- 2) torque 65 Nm (48 lbf ft)
Endress+Hauser
27
Ceraphant PTP33B
## Hygienic connections
**==> picture [517 x 320] intentionally omitted <==**
**----- Start of picture text -----**<br>
A ø35 (1.38) B ø48 (1.89)<br>ø27 (1.06)<br>ø39 (1.54)<br>ø43.4 (1.71)<br>ø55.4 (2.18)<br> A0021956 A0021957<br>C ø61 (2.4) D<br>ø51 (2.01) ø55 (2.17)<br>ø67.4 (2.65) A0021974<br> A0021958<br>Engineering unit mm (in). Diameter of process isolating diaphragm: 17.2 mm (0.68 in)<br>28 (1.1)<br>28 (1.1)<br>3 (0.12) 10 (0.39)<br>3 (0.12) 10 (0.39)<br>4 (0.16) 28 (1.1)<br>28 (1.1)<br>3 (0.12) 11 (0.43)<br>**----- End of picture text -----**<br>
|Position|Designation|Nominal pressure|Material1)|Weight|Approval|Option2)|
|---|---|---|---|---|---|---|
|||PN||kg (lbs)|||
|A|DIN 11851 DN 25|40|316L|0.360 (0.79)|3A, EHEDG, CRN|1GJ|
|B|DIN 11851 DN 40|40|316L|0.520 (1.15)|3A, EHEDG, CRN|1JJ|
|C|DIN 11851 DN 50|25|316L|0.760 (1.68)|3A, EHEDG, CRN|1DJ|
|D|SMS 1 ½"|25|316L|0.440 (0.97)|3A, CRN|4QJ|
1) Roughness of wetted surfaces Ra ≤0.76 μm (29.9 μin).
2) Product Configurator, order code for "Process connection"
Endress+Hauser
28
Ceraphant PTP33B
## Hygienic connections
**==> picture [517 x 373] intentionally omitted <==**
**----- Start of picture text -----**<br>
A<br>ø34 (1.34)<br> A0022800<br>B C<br>ø50.5 (1.99) ø64 (2.52)<br> A0021976 A0021979<br>D ø57 (2.24) E ø75 (2.95)<br>ø66 (2.6) ø84 (3.31)<br> A0021981 A0021980<br>Engineering unit mm (in). Diameter of process isolating diaphragm: 17.2 mm (0.68 in)<br>28 (1.1)<br>28 (1.1) 28 (1.1)<br>28 (1.1) 28 (1.1)<br>19 (0.75) 12.3 (0.48) 19 (0.75) 12.3 (0.48)<br>**----- End of picture text -----**<br>
|Item|Description|Approval|Nominal pressure|Material1)|Weight|Option2)|
|---|---|---|---|---|---|---|
||||PN||kg (lbs)||
|A|Clamp ISO 2852 DN22|3A, EHEDG, CRN|40|316L|0.090 (0.20)|3AJ|
|B|Tri-Clamp ISO 2852 DN 25 – DN 38 (1 ½"), DIN32676 DN25-38|3A, EHEDG, CRN|40|316L|0.160 (0.35)|3CJ|
|C|Tri-Clamp ISO 2852 DN 40 – DN 51 (2"), DIN32676 DN50,<br>EHEDG, 3A|3A, EHEDG, CRN|40|316L|0.230 (0.51)|3EJ|
|D|Varivent F pipe DN25-32|3A, EHEDG, CRN|40|316L|0.350 (0.77)|41J|
|E|Varivent N pipe DN40-162|3A, EHEDG, CRN|40|316L|0.630 (1.39)|42J|
1) Roughness of wetted surfaces Ra ≤0.76 μm (29.9 μin).
2) Product Configurator, order code for "Process connection"
Endress+Hauser
29
Ceraphant PTP33B
## Materials in contact with process
## NOTICE
- ‣ Device components in contact with the process are listed in the "Mechanical construction" and "Ordering information" sections.
## TSE Certificate of Suitability
The following applies to all device components in contact with the process:
- They do not contain any materials derived from animals.
- No additives or operating materials derived from animals are used in production or processing.
## Process connections
- Endress+Hauser supplies a threaded connection made of stainless steel in accordance with AISI 316L (DIN/ EN material number 1.4404 or 1.4435). With regard to their stability-temperature property, the materials 1.4404 and 1.4435 are grouped together under 13E0 in EN 1092-1: 2001 Tab. 18. The chemical composition of the two materials can be identical.
- "Clamp connections" and "Hygienic process connections": AISI 316L (DIN/EN material number 1.4435)
## Process isolating diaphragm
|Description|Material|
|---|---|
|Metal process isolating diaphragm|AISI 316L (DIN/EN material number 1.4435)|
## Seals
See the specific process connection.
Endress+Hauser
30
Ceraphant PTP33B
|Materials not in contact with<br>process|Housing|Housing|Housing|
|---|---|---|---|
||2<br>3<br>1<br>A0022245<br>6<br>7<br>5<br>4<br>A0027292|||
|||||
||Item number|Component part|Material|
||1|Housing with valve plug connection|• Seal: NBR<br>• Plug: PA<br>• Screw: V2A<br>• Adapter plate: PBT/PC<br>• Housing: PBT/PC|
||2|Housing prepared for M12 plug connection|• Adapter plate: PBT/PC<br>• For other materials, see the "Accessories" section<br>• Housing: PBT/PC|
||3|Housing with cable connection|• Pressure screw: PVDF<br>• Seal: TPE-V<br>• Cable: PUR (UL 94 V0)<br>• Adapter plate: PBT/PC<br>• Housing: PBT/PC|
||4|Design element|PBT/PC|
||5|Nameplates|Lasered directly onto the housing|
||6|Housing|316L (1.4404)|
||7|Pressure compensation element|316L (1.4404)|
||Filling oil|Filling oil|Filling oil|Filling oil|
|---|---|---|---|---|
||Device|Filling oil|||
||PTP33B|Synthetic oil polyalphaolefin FDA 21 CFR 178.3620, NSF H1|||
||||||
|Cleaning|Device||Description|Option1)|
||PTP33B||Cleaned from oil+grease|HA|
||1)<br>Product Configurator, order code for "Service"||||
Endress+Hauser
31
Ceraphant PTP33B
## Operability
## IO-Link (optional)
Operating concept for devices with IO-Link
_Operator-oriented menu structure for user-specific tasks_
_Quick and safe commissioning_
Guided menus for applications
## _Reliable operation_
Operation in the following languages: Via IO-Link: English
_Efficient diagnostics increase measurement availability_
- Remedial measures
- Simulation options
## IO-Link information
IO-Link is a point-to-point connection for communication between the measuring device and an IOLink master. The measuring device features an IO-Link communication interface type 2 with a second IO function on pin 4. This requires an IO-Link-compatible assembly (IO-Link master) for operation. The IO-Link communication interface enables direct access to the process and diagnostic data. It also provides the option of configuring the measuring device on the fly.
Physical layer, the measuring device supports the following features:
- IO-Link specification: version 1.1
- IO-Link Smart Sensor Profile 2nd Edition (supports minimum scope of IdentClass)
- SIO mode: yes
- Speed: COM2; 38.4 kBaud
- Minimum cycle time: 2.5 msec.
- Process data width: 32 bit
- IO-Link data storage: yes
- Block parameterization: yes
## IO-Link download
http://www.endress.com/download
- Select "Software" as the media type.
- Select "Device Driver" as the software type. Select IO-Link (IODD).
- In the "Text Search" field enter the device name.
https://ioddfinder.io-link.com/
Search by
- Manufacturer
- Article number
- Product type
Operation with local display
## Overview
A 1-line liquid crystal display (LCD) is used for display and operation. The local display shows measured values, fault messages and information messages and therefore supports the user through each operating step.
During measuring operation, the display shows measured values, fault messages and notice messages. In addition, it is possible to switch to menu mode via the operating keys.
Endress+Hauser
32
Ceraphant PTP33B
**==> picture [387 x 177] intentionally omitted <==**
**----- Start of picture text -----**<br>
4 5<br>3<br>2<br>E<br>1<br> A0022121<br>1 Operating keys<br>2 Status LED<br>3 Switch output LEDs<br>4 Measured value<br>5 Unit<br>**----- End of picture text -----**<br>
The second switch output is not used for the device version with current output.
## Functions:
- 4-digit measured value display and decimal point
- Simple and complete menu guidance due to breakdown of parameters into several levels and groups
- Possibility to configure the display in accordance with individual wishes and requirements
- Comprehensive diagnostic functions (fault and warning message, peak-hold indicators, etc.)
- Quick and safe commissioning
- The device also signals the status via LEDs.
## Information on the operational states
|Operational states|Function of status-LED and onsite display|
|---|---|
|Operation|• Status LED is lit green<br>• LEDs of switch output 1 and switch output 2 signal the status of each switch output<br>• No activity of LED for switch output 2 if current output is active<br>• White background lighting|
|Problem|• Status LED lit steady red<br>• Red display background<br>• LED of switch output 1 and switch output 2 off (switch output is deactivated)|
|Warning|• Status LED flashing red<br>• White display background<br>• LEDs of switch output 1 and switch output 2 signal the status of each switch output|
|For Device Search|• The green LED is lit (= operational) on the device and starts to flash with increased<br>luminosity. Flash frequency<br>• LEDs of switch output 1 and switch output 2 signal the status of each switch output<br>• Display background depending on the device status|
|IO-Link<br>communication|• Status LED flashes green as per IO-Link specification (regardless of measuring<br>operation, error or warning). Flash frequency<br>• Display background depending on the device status<br>• The state of switch output 1 is also indicated via the LED of switch output 1 at the same<br>time as the process data are displayed|
Device Search (IO-Link)
The Device Search parameter is used to uniquely identify the device during installation.
Endress+Hauser
33
Ceraphant PTP33B
Functions of switch output
The switch output can be used for two-point control (hysteresis) or for monitoring a process pressure range (window function).
## Hysteresis
Sample explanation. Device with two switch outputs.
**==> picture [288 x 168] intentionally omitted <==**
**----- Start of picture text -----**<br>
p<br>SP1/SP2<br>2<br>RP1/RP2<br>1<br>0 HNO<br>1 HNC<br>0<br>t<br>**----- End of picture text -----**<br>
**==> picture [22 x 4] intentionally omitted <==**
**----- Start of picture text -----**<br>
A0022943<br>**----- End of picture text -----**<br>
- _ 1 SP1/SP2: switch point 1/2; RP1/RP2: switch-back point 1/2_
- _0 0-signal. Output open in quiescent state._
- _1 1-signal. Output closed in quiescent state._
- _2 Hysteresis_
_HNO Closing_
_HNC NC contact_
## _Description_
When the set switch point "SP1/SP2" is reached (with increasing pressure), an electrical signal change takes place at the switch output.
When the set switchback point "RP1/RP2" is reached (with decreasing pressure), an electrical signal change takes place at the switch output.
The difference between the value of the switch point "SP1/SP2" and the switchback point "RP1/RP2" is known as the hysteresis.
Endress+Hauser
34
Ceraphant PTP33B
## Window function
Sample explanation. Device with two switch outputs.
**==> picture [288 x 167] intentionally omitted <==**
**----- Start of picture text -----**<br>
p<br>FH1/FH2<br>2<br>FL1/FL2<br>1<br>0 FNO<br>1 FNC<br>0<br>t<br>**----- End of picture text -----**<br>
**==> picture [22 x 4] intentionally omitted <==**
**----- Start of picture text -----**<br>
A0027370<br>**----- End of picture text -----**<br>
- _ 2 FH1/FH2: upper value of pressure window; FL1/FL2: lower value of pressure window_
- _0 0-signal. Output open in quiescent state._
- _1 1-signal. Output closed in quiescent state._
- _2 Pressure window (difference between the value of the high window "FH1/FH2" and the low window "FL1/ FL2")_
- _FNO Closing_
- _FNC NC contact_
## _Description_
When the lower value of the pressure window "FL1/FL2" is reached (with increasing or decreasing pressure), an electrical signal change takes place at the switch output.
When the upper value of the pressure window "FH1/FH2" is reached (with increasing or decreasing pressure), an electrical signal change takes place at the switch output.
The difference between the upper value of the pressure window "FH1/FH2" and the lower value of the pressure window "FL1/FL2" is known as the pressure window.
Endress+Hauser
35
Ceraphant PTP33B
## Certificates and approvals
CE mark
RoHS
RCM-Tick marking
The device meets the legal requirements of the relevant EC directives. Endress+Hauser confirms that the device has been successfully tested by applying the CE mark.
The measuring system complies with the substance restrictions of the Restriction on Hazardous Substances Directive 2011/65/EU (RoHS 2).
The supplied product or measuring system meets the ACMA (Australian Communications and Media Authority) requirements for network integrity, interoperability, performance characteristics as well as health and safety regulations. Here, especially the regulatory arrangements for electromagnetic compatibility are met. The products are labelled with the RCM- Tick marking on the name plate.
**==> picture [47 x 36] intentionally omitted <==**
A0029561
## Suitability for hygienic processes
All materials in contact with foodstuffs comply with framework regulation (EC) 1935/2004. The device is available with hygienic process connections (overview: see order code).
## L[CAUTION]
## Contamination in the process!
Risk of contamination if incorrect seals and parts are used!
- ‣ To avoid the risk of contamination, when installing the device comply with the design principles of EHEDG, Guideline 37 "Hygienic Design and Application of Sensors" and Guideline 16 "Hygienic Pipe Couplings".
- ‣ Suitable assemblies and seals must be used to ensure hygienic design in accordance with 3-A SSI and EHEDG specifications.
- ‣ The leak-proof connections can be cleaned with the cleaning methods typical of this industry (CIP and SIP). Attention must be paid to the pressure and temperature specifications of the sensor and process connections for CIP and SIP processes (clean in place/sterilize in place).
The seamless connections can be cleaned of all residue using any of the typical cleaning methods within this industry.
**==> picture [387 x 139] intentionally omitted <==**
**----- Start of picture text -----**<br>
74 -<br>TYPE EL<br>CLASS I<br>OCTOBER 2014<br> A0025304<br>**----- End of picture text -----**<br>
Pressure Equipment Directive 2014/68/EU (PED)
## Pressure equipment with allowable pressure ≤ 200 bar (2 900 psi)
Pressure equipment (with a maximum allowable pressure PS ≤ 200 bar (2 900 psi)) can be classified as pressure accessories in accordance with Pressure Equipment Directive 2014/68/EU. If the maximum allowable pressure is ≤ 200 bar (2 900 psi) and the pressurized volume of the pressure equipment is ≤ 0.1 l, the pressure equipment is subject to the Pressure Equipment Directive (cf. Pressure Equipment Directive 2014/68/EU, Article 4, point 3). The Pressure Equipment Directive only requires that the pressure equipment shall be designed and manufactured in accordance with the "sound engineering practice of a Member State".
Endress+Hauser
36
Ceraphant PTP33B
_Reasons:_
- Pressure Equipment Directive (PED) 2014/68/EU Article 4, point 3
- Pressure equipment directive 2014/68/EU, Commission's Working Group "Pressure", Guideline A-05 + A-06
_Note:_
A partial examination shall be performed for pressure instruments that are part of safety equipment for the protection of a pipe or vessel from exceeding allowable limits (safety accessory in accordance with Pressure Equipment Directive 2014/68/EU, Article 2, point 4).
## Manufacturer declarations
Depending on the desired configuration, the following documents can be ordered additionally with the device:
- FDA conformity
- TSE-free: materials free from animal origin
- Regulation (EC) No. 2023/2006 (GMP)
- Regulation (EC) No. 1935/2004 on materials and articles intended to come into contact with food
Downloading the Declaration of Conformity
http://www.endress.com/en/download
**==> picture [386 x 190] intentionally omitted <==**
**----- Start of picture text -----**<br>
videos, certificates and a whole host of other documents! 2<br>1<br>Media Type<br>3<br>4<br>Frese] earch<br> A0031778<br>1. Select "Approvals & Certificates"<br>2. Select "Manufact. Declaration"<br>3. Enter the required product code<br>4. Click "Search"<br>The available downloads are displayed.<br>**----- End of picture text -----**<br>
Other standards and The applicable European guidelines and standards can be found in the relevant EU Declarations of guidelines Conformity. The following standards were also applied: DIN EN 60770 (IEC 60770):
Transmitters for use in industrial process control systems Part 1: Methods for performance evaluation Methods for evaluating the performance of transmitters for control and regulation in industrial process control systems. DIN 16086: Electrical pressure measuring instruments, pressure sensors, pressure transmitters, pressure measuring instruments, concepts, specifications on data sheets Procedure for writing specifications in data sheets for electrical pressure measuring instruments, pressure sensors and pressure transmitters.
Endress+Hauser
37
Ceraphant PTP33B
## EN 61326-X:
EMC product family standard for electrical equipment for measurement, control and laboratory use.
## EN 60529:
Degrees of protection provided by enclosures (IP code)
## NAMUR - User association of automation technology in process industries.
NE21 - Electromagnetic Compatibility (EMC) of Industrial Process and Laboratory Control Equipment.
NE43 - Standardization of the Signal Level for the Failure Information of Digital Transmitters.
NE44 - Standardization of Status Indicators on PCT Instruments with the Help of Light Emitting Diodes
NE53 - Software of Field Devices and Signal-processing Devices with Digital Electronics
NE107 - Self-monitoring and Diagnosis of Field Devices
## VDMA 24574-1:2008-04
Fluid technology terms, menu navigation and electrical connection for fluid sensors, Part 1: Pressure switches
## CRN approval
A CRN approval is available for some device versions. A CRN-approved process connection with a CSA approval must be ordered for a CRN-approved device. The CRN-approved devices are assigned the registration number 0F18141.5C.
Ordering information: Product Configurator, order code for "Process connection" (the CRN process connections are indicated appropriately in the "Mechanical construction" section.)
## Calibration unit
|Designation|Option1)|
|---|---|
|Sensor range; %|A|
|Sensor range; mbar/bar|B|
|Sensor range; kPa/MPa|C|
|Sensor range; psi|F|
|Switch 1; see additional spec.|S|
|Switch 1 + 2; see additional spec.|T|
|Switch, analog output; see additional spec.|U|
1) Product Configurator, order code for "Calibration; unit"
## Calibration
## Inspection certificates
|Designation|Option1)|
|---|---|
|3-point certificate of calibration|F3|
|1)<br>Product Configurator order code for "Calibration"||
|Device|Designation|Option1)|
|---|---|---|
|PTP33B|3.1 Material documentation, wetted metal parts, EN10204-3.1 inspection certificate|JA|
|PTP33B|Surface finish measurement ISO4287/Ra, wetted metal parts, inspection certificate|KB|
- 1) Product Configurator, order code for "Test, Certificate"
Endress+Hauser
38
Ceraphant PTP33B
|Additional approval|Device|Designation|Option1)|
|---|---|---|---|
||PTP33B|EHEDG, certificate copy|L1|
||PTP33B|3A, certificate copy|L2|
||PTP33B|Declaration of Conformity EC1935/2004, wetted parts|L3|
- 1) Product Configurator, order code for "Additional approval"
## Ordering information
Detailed ordering information is available from the following sources:
- In the Product Configurator on the Endress+Hauser website: www.endress.com -> Click "Corporate" -> Select your country -> Click "Products" -> Select the product using the filters and search field -> Open product page -> The "Configure" button to the right of the product image opens the Product Configurator.
- From your Endress+Hauser Sales Center: www.addresses.endress.com
Product Configurator - the tool for individual product configuration
- Up-to-the-minute configuration data
- Depending on the device: Direct input of measuring point-specific information such as measuring range or operating language
- Automatic verification of exclusion criteria
- Automatic creation of the order code and its breakdown in PDF or Excel output format
- Ability to order directly in the Endress+Hauser Online Shop
Scope of delivery
- Measuring device
- Optional accessories
- Brief Operating Instructions
- Certificates
Endress+Hauser
39
Ceraphant PTP33B
## Accessories
## Weld-in adapter
Various weld-in adapters are available for installation in vessels or pipes.
|Device|Description|Option1)|Order number|
|---|---|---|---|
|PTP33B|Weld-in adapter M24, d=65, 316L|PM|71041381|
|PTP33B|Weld-in adapter M24, d=65, 316L 3.1 EN10204-3.1<br>material, inspection certificate|PN|71041383|
|PTP33B|Weld-in adapter G1, 316L, conical metal joint|QE|52005087|
|PTP33B|Weld-in adapter G1, 316L, 3.1, conical metal joint,<br>EN10204-3.1 material, inspection certificate|QF|52010171|
|PTP33B|Weld-in tool adapter G1, brass|QG|52005272|
|PTP33B|Weld-in adapter G1, 316L, silicone O-ring seal|QJ|52001051|
|PTP33B|Weld-in adapter G1, 316L, 3.1, silicone O-ring seal,<br>EN10204-3.1 material, inspection certificate|QK|52011896|
- 1) Product Configurator, order code for "Enclosed accessories"
If installed horizontally and weld-in adapters with a leakage hole are used, ensure that the leakage hole is pointing down. This allows leaks to be detected as quickly as possible.
Process adapter M24
The following process adapters can be ordered for the process connections with order option X2J and X3J:
|Device|Description|Order number|Order number with inspection certificate 3.1 EN10204|
|---|---|---|---|
|PTP33B|Varivent F DN32 PN40|52023996|52024003|
|PTP33B|Varivent N DN50 PN40|52023997|52024004|
|PTP33B|DIN11851 DN40|52023999|52024006|
|PTP33B|DIN11851 DN50|52023998|52024005|
|PTP33B|SMS 1½"|52026997|52026999|
|PTP33B|Clamp 1½"|52023994|52024001|
|PTP33B|Clamp 2"|52023995|52024002|
Endress+Hauser
40
Ceraphant PTP33B
## M12 plug connectors
|Connector|Degree of protection|Material|Option1)|Order number|
|---|---|---|---|---|
|M12<br>(self-terminated connection<br>at M12 plug)<br>53 (2.09)<br>ø20<br>(0.8)<br>A0024475|IP67|• Union nut: Cu Sn/Ni<br>• Body: PBT<br>• Seal: NBR|R1|52006263|
|M12 90 degrees<br>with 5m (16 ft) cable<br>27<br>(1.06)<br>40 (1.57)<br>�<br>A0024476|IP67|• Union nut: GD Zn/Ni<br>• Body: PUR<br>• Cable: PVC<br>Cable colors<br>• 1 = BN = brown<br>• 2 = WT = white<br>• 3 = BU = blue<br>• 4 = BK = black|RZ|52010285|
|M12 90 degrees<br>(self-terminated connection<br>at M12 plug)<br>35<br>(1.38)<br>28<br>(1.1)<br>20 (0.79)<br>A0024478|IP67|• Union nut: GD Zn/Ni<br>• Body: PBT<br>• Seal: NBR|RM|71114212|
- 1) Product Configurator, order code for "Enclosed accessories"
Endress+Hauser
41
Ceraphant PTP33B
## Documentation
Field of Activities Pressure measurement, powerful instruments for process pressure, differential pressure, level and flow: FA00004P Technical Information • TI00241F: EMC Test Procedures • TI00426F: Weld-in adapters, process adapters and flanges (overview) Operating Instructions BA01270P Devices with IO-Link: BA01911P Brief Operating Instructions KA01163P Devices with IO-Link: KA01404P
## Registered trademarks
is a registered trademark of the IO-Link company group.
Endress+Hauser
42
*71422363* 71422363
www.addresses.endress.com
Updated at June 9, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →