PTFZ-08-E
Relay Socket, DIN Rail, Screw, 8 Pins, 15 A, 250 V, PTF Series
- Manufacturer: OMRON INDUSTRIAL AUTOMATION
- Product type: Relay Sockets
- SVHC: To Be Advised
- No. of Pins: 8Pins
- Product Range: PTF Series
- Current Rating: 15A
- Voltage Rating: 250V
- Socket Mounting: DIN Rail
- Socket Terminals: Screw
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 5.66 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **Electronic Thermostat E5L**
## **Ideal for Simple Built-in Control.**
- A high switching capacity of 10 A at 250 VAC enables direct load switching.
- A sensor is provided to enable immediate application.
- Sockets with finger protection (PTF14A-E), without finger protection (PTF14A) and Socket with Push-In Plus technology (PTF-14-PU-L) can be used.
- Simple operation and settings. Even simpler with digital models.
## **Model Number Structure**
## **Model Number Legend**
## **E5L-** @@
**1 2**
1. Setting and Indication Methods 2. Set temperature A: Analog setting, no display − 30-20 : − 30 to +20 ° C C: Digital setting, display 0-50 : 0 to +50 ° C 0-100 : 0 to +100 ° C 100-200 : +100 to +200 ° C
## **Ordering Information**
## **Electronic Thermostats**
## **E5L-A** @
|**Size**|**Type**|**Control method**|**Control**<br>**output**|**Model**|
|---|---|---|---|---|
|45×35 mm|Plug-in|ON/OFF operation|Relay|**E5L-A -30-20**|
|||||**E5L-A 0-50**|
|||||**E5L-A 0-100**|
|||||**E5L-A 100-200**|
## **E5L-C** @
|**Size**|**Type**|**Control method**|**Control**<br>**output**|**Model**|
|---|---|---|---|---|
|45×35 mm|Plug-in|ON/OFF operation|Relay|**E5L-C -30-20**|
|||||**E5L-C 0-100**|
|||||**E5L-C 100-200**|
**Note:** The E5L-C is not available with a set temperature range of 0 to 50 ° C.
## **Options (Order Separately)**
## **Mounting Brackets**
**Model**
## **Y92H-10**
**Note:** This Mounting Brackets is provided with the Electronic Thermostat.
## **Sockets**
|**Type**|**Model**|
|---|---|
|Front-connecting Socket|**PTF14A**|
||**PTFZ-14-E**|
||**PTF-14-PU-L**|
**1**
**E5L**
## **Ratings and Characteristics**
## **Ratings**
|**Item**<br>**Model**|**E5L-A**@|**E5L-C**@|
|---|---|---|
|**Power supply voltage**|100 to 240 VAC, 50/60 Hz||
|**Operating voltage range**|85% to 110% of the rated supply voltage||
|**Power consumption**|Approx. 3 VA||
|**Inputs**|Element-interchangeable thermistor||
|**Control method**|ON/OFF control||
|**Control output**|SPDT contacts, 250 VAC, 10 A, cosφ= 1 (resistive load)|SPST-NO contacts, 250 VAC, 10 A, cosφ= 1 (resistive load)|
|**Setting method**|Analog setting|Digital settings using keys on front panel|
|**Indication method**|No display|LCD digital display (character height: 12 mm)|
|**Other functions**||• Setting protection (key protection)<br>• Input shift<br>• Direct/reverse operation|
|**Ambient temperature**|−10 to 55°C (with no icing or condensation)||
|**Ambient humidity**|25% to 85%||
|**Storage temperature**|−25°C to 65°C (with no icing or condensation)||
**Note:** Do not use the output from an Inverter as the power supply.
## **Characteristics**
|**Item**<br>**Model**|**E5L-A**@|**E5L-C**@|
|---|---|---|
|**Indication accuracy**|---|±(1°C + 1 digit) max.*1|
|**Setting accuracy**|---|±(1°C + 1 digit) max.*1|
|**Hysteresis**|−30 to 20°C models: Approx. 0.5 to 2.5°C (variable)<br>0 to 50°C models: Approx. 0.5 to 4°C (variable)<br>0 to 100°C models: Approx. 0.5 to 4°C (variable)<br>100 to 200°C models: Approx. 0.7 to 4°C (variable)|1 to 9°C (in increments of 1°C)|
|**Repeat accuracy**|1% FS max.|---|
|**Minimum scale**<br>**(standard scale)**|−30 to 20°C models and 0 to 50°C models: 5°C<br>0 to 100°C models and 100 to 200°C models: 10°C|---|
|**Influence of temperature**|---|±((1% of PV or 2°C, whichever is greater) +1 digit) max.|
|**Influence of voltage**|---||
|**Influence of EMS.**<br>**(at EN61326-1)**|---||
|**Sampling period**|---|2 s|
|**Insulation resistance**|100 MΩmax. (at 500 VDC)||
|**Dielectric strength**|2,810 VAC, 50/60 Hz for 1 min (between charged terminals and uncharged metallic parts, between power supply<br>terminals and input terminals, between power supply terminals and output terminals, and between input terminals<br>and output terminals)||
|**Vibration (malfunction)**|Frequency of 10 to 55 Hz, 0.5-mm double amplitude for 10 min each in X, Y, and Z directions||
|**Vibration (destruction)**|Frequency of 10 to 55-Hz, 0.75-mm double amplitude for 2 h each in X, Y, and Z directions||
|**Shock (malfunction)**|150 m/s2, 3 times each in 6 directions|100 m/s2, 3 times each in 6 directions|
|**Shock (destruction)**|300 m/s2, 3 times each in 6 directions||
|**Electrical life expectancy**<br>**(control output relay)**|100,000 operations min (at maximum applicable load)||
|**Memory protection**|---|Non-volatile memory (100,000 write operations)|
|**Weight (Thermostat)**|Approx. 80 g (Thermostat only)||
|**Degree of protection**|Front panel: IP40, Terminals: IP00||
|**Approved standards**|---||
|**Conformed standards**|EN 61010-1 (IEC 61010-1), Pollution Degree 2, Overvoltage Category II||
|**EMC Directives**|EMI:<br>EN61326-1*2<br>Radiated EMI:<br>EN55011 Group1 ClassA<br>Conducted EMI:<br>EN55011 Group1 ClassA<br>EMS:<br>EN61326-1*2<br>Electrostatic discharge immunity:<br>EN61000-4-2<br>Electromagnetic field strength immunity:<br>EN61000-4-3<br>Burst noise immunity:<br>EN61000-4-4<br>Conducted disturbance immunity:<br>EN61000-4-6<br>Surge immunity:<br>EN61000-4-5<br>Voltage dip and power interruption immunity: EN6100-4-11||
*1. The accuracy of the accessory thermistor is not included.
*2. Industrial electromagnetic environment (EN/IEC 61326-1 Table 2)
**2**
**E5L**
## **External Connections**
**==> picture [487 x 159] intentionally omitted <==**
**----- Start of picture text -----**<br>
E5L-A @ E5L-C @<br>Control output [*] Control output [*]<br>250 VAC, 10 A 250 VAC, 10 A<br>Element- Element-<br>o a 10m 12 _ _—__! 9 = 12 _ _—_!<br>interchangeable interchangeable<br>Thermistor 13 q 14 [ Thermistor 13 [ 14 [<br>Input power supply: 100 to 240 VAC Input power supply: 100 to 240 VAC<br>* Control output Heating load: Terminals 8 and 12 * Control outputs: Terminals 8 and 12<br>Cooling load: Terminals 4 and 12 Use the keys on the front panel to set direct/reverse operation.<br>Be careful of the cooling load contacts, because they will be electrically<br>charged even when the E5L input power supply is OFF.<br>**----- End of picture text -----**<br>
**Note:** For thermistor wiring, separate the input power supply and load lines as much as possible to avoid the influence of inductive noise.
## **Nomenclature**
## **E5L-A** @
## **Operation Indicator**
**==> picture [49 x 16] intentionally omitted <==**
**----- Start of picture text -----**<br>
Hysteresis<br>adjuster (DIFF.)<br>**----- End of picture text -----**<br>
|**Operation**<br>**indicator**|**Output status**|**Output status**|
|---|---|---|
||**Heating load**|**Cooling load**|
|**Lit red.**|ON|OFF|
|**Not lit.**|OFF|ON|
**==> picture [60 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Operation indicator<br>**----- End of picture text -----**<br>
Temperature dial
## **E5L-C** @
**==> picture [248 x 29] intentionally omitted <==**
**----- Start of picture text -----**<br>
Operation indicator —n<br>Process value<br>Set value indicator —h and set value<br>Protection indicator display<br>**----- End of picture text -----**<br>
**==> picture [130 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Mode Key Down Key Up Key<br>**----- End of picture text -----**<br>
**==> picture [188 x 113] intentionally omitted <==**
**----- Start of picture text -----**<br>
Operation Indicator: ON<br>Output status<br>Operation<br>indicator Reverse Direct operation<br>operation<br>Lit ON ON<br>Not lit OFF OFF<br>Set Value Indicator: SV<br>——<br>Lit when the set value is displayed.<br>Setting Protection Indicator: on<br>Lit when setting protection is set.<br>**----- End of picture text -----**<br>
**3**
**E5L**
**(Unit: mm)**
## **Dimensions**
## **Thermostats**
**==> picture [34 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
E5L-A @<br>**----- End of picture text -----**<br>
**==> picture [34 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
E5L-C @<br>**----- End of picture text -----**<br>
**==> picture [265 x 150] intentionally omitted <==**
**----- Start of picture text -----**<br>
35 of} | ro He + to p<br>45 (4.6) 64 6.4<br>75.0<br>35<br>im) IP<br>(ty) iP<br>45 64 6.4<br>70.4<br>**----- End of picture text -----**<br>
## **Wiring Connection Sockets (Order Separately)**
**==> picture [104 x 16] intentionally omitted <==**
**----- Start of picture text -----**<br>
Terminal Arrangement and<br>Internal Connections<br>**----- End of picture text -----**<br>
**==> picture [499 x 459] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions Internal Connections Mounting Hole Dimensions<br>PTF14A Two, 4.5 x 6 mounting holes 7 [±0.2] 3.4 (TOP VIEW)<br>Note: Can be mounted to a DIN Track.<br>14, M3.5 x 8<br>7 eee Sems screws<br>Misioiclc!<br>| _ J ol f olfe l fe l _<br>ooodno<br>onooono<br>78.5 max. onooono 35.5 68 [±0.3] 1 1<br>Oo Oo<br>(TOP VIEW)<br>ISIS a<br>Ie est<br>4 5.5 max . 8 4 3 2 1 36 [±0.2] Two, M4 or<br>aL 30 max Ht . 8 7 6 5 4.5-dia. holes<br>PTFZ-14-E (Finger Protection Structure) (TOP VIEW)<br>Two, 4.5 × 6 7 3.4 Note: Can be mounted to a DIN Track.<br>mounting holes<br>14-M3.5×7 12 11 10 9 Two, 4.5 dia. or<br>14 13 M4 mounting holes<br>78.5 max. y1 oOo 35.5 68 [±0.3] ||<br>=<br>e<br>a<br>45.5 max. 8<br>33 max. 19 [±0.2]<br>PTF-14-PU-L Socket with Push-In Plus technology (TOP VIEW) (TOP VIEW)<br>48.2 41 31 21 11 Two, M3 screw hole or<br>45 (12) (11) (10) (9) two, 3.5 dia. hole<br>— 43.4 — 36.3 | LJOOo 44 CI 34 CI 24 14 CI WA<br>27.6 3.9 (8) (7) (6) (5)<br>(4.2) 42 32 22 12<br>(4) (3) (2) (1)<br>27.4<br>108<br>90<br>35.3<br>(14) (13)<br>A2 A1<br>(4.2) a, Note: The numbers in<br>27.6 parentheses are<br>28.1 traditionally used Note: Pull out the hooks to mount<br>30.3 terminal numbers. the Relay with screws.<br>**----- End of picture text -----**<br>
**4**
**E5L**
## **Accessories**
## **E52-THE-E5L Element-interchangeable Thermistor**
**Included with the following models:** − **30 to 20** ° **C.**
**==> picture [502 x 334] intentionally omitted <==**
**----- Start of picture text -----**<br>
(5.5-dia.) PVC cable (12/0.18) Color code<br>10 Temperature Range<br>(15) (30)<br>30 500 (60) Temperature range Color code resistanceNominal Thermistor constant Lead wires<br>Included with the following models: 0 to 50 ° C and 0 to 100 ° C. 0 to 100 − 30 to 20 ° C ° C * BlackBlue 6 k6 k ΩΩ (0 (0 °° C)C) 3,390 K3,390 K Heat-resistant PVC cable<br>(5.5-dia.) Color code PVC cable (12/0.18) === 100 to 200 ° C Yellow 0.55 k(200 ° C) Ω 4,300 K PTFE<br>Note: PVC cable is heat resistant from − 40 to 105 ° C.<br>1 0 PTFE cable is heat resistant from − 40 to 250 ° C.<br>30 500 30 * Use a 0 to 100 ° C thermistor for 0 to 50 ° C applications.<br>Tolerance<br>Included with 100 to 200 ° C Models.<br>Measured temperature Tolerance<br>5-dia. max. PTFE cable (7/0.2) Color code − 30 to 100 ° C ± 2 ° C max.<br>100 to 200 ° C Measured temperature ± 2% max.<br>10<br>1 5 60<br>—— 30 500 e=<br>Y92H-10 Mounting Brackets (Two)<br>Note: Included with product.<br>4.5 If a mounting bracket is missing or damaged, order<br>a new bracket separately.<br>6.9 2<br>63.7<br>1.6 10.3<br>**----- End of picture text -----**<br>
## **Temperature Sensors (Order Separately)**
E52-THE5A, E52-THE6D, and E52-THE6F Temperature Sensors can be ordered separately. For details, refer to an _OMRON Web site_ .
**5** omRON ~~a~~
**E5L**
## **Operating the E5L-C** @
**==> picture [77 x 32] intentionally omitted <==**
**----- Start of picture text -----**<br>
Power ON<br>**----- End of picture text -----**<br>
**==> picture [293 x 173] intentionally omitted <==**
**----- Start of picture text -----**<br>
Temperature Input Shift Direct/Reverse<br>Operation<br>Press the Key Press the Key<br>for at least 3 s. for at least 3 s.<br>Process value<br>Press the Key for at least 3 s.<br>Press the Key Control stops.<br>for less than 1 s.<br>Set<br>temperature<br>Press the Key<br>for less than 1 s.<br>**----- End of picture text -----**<br>
**==> picture [222 x 86] intentionally omitted <==**
**----- Start of picture text -----**<br>
Setting Protection<br>Press the Press the<br>and Keys and Keys<br>for at least 1 s. for at least 1 s.<br>Set temperature Process value<br>display display<br>Press the and Keys for at least 1 s.<br>**----- End of picture text -----**<br>
**==> picture [89 x 40] intentionally omitted <==**
**----- Start of picture text -----**<br>
Hysteresis<br>Press the Key<br>for less than 1 s.<br>**----- End of picture text -----**<br>
## **Set temperature**
**1.** Press the Key to enter the Set Temperature Mode.
**2.** Press the and Keys to set the temperature. The display will continue to change for as long as the key is held down.
**Note:** The default setting is the lowest temperature in the range.
## **Setting the Hysteresis**
**1.** Press the Key to enter the Hysteresis Mode.
**2.** Press the and Keys to set the value. Each time the key is pressed, the setting will change by 1 ° C. The setting will not continue to change even if the key is held down. The key must be released after each change. The hysteresis can be set from 1 to 9 ° C, in increments of 1 ° C.
**Note:** The default setting is 1 ° C.
|**Hysteresis**|**Display**|
|---|---|
|+1°C<br>5°C||
|+<br>+9°C||
|**Reverse Operation (Heating Control)**<br>**Direct Operation (Cooling Control)**||
**==> picture [237 x 95] intentionally omitted <==**
**----- Start of picture text -----**<br>
Hysteresis Hysteresis<br>ON ON<br>OFF OFF<br>Less than (Set Set temperature Less than set (Set temperature -<br>temperature - or more temperature Hysteresis) or more<br>Hysteresis)<br>Control output Control output<br>**----- End of picture text -----**<br>
## **Setting the Temperature Input Shift**
**1.** Press the Key for at least 3 s to enter the Temperature Input Shift Mode.
**2.** Press the and Keys to set the value. Each time the key is pressed, the setting will change by 1 ° C. The setting will not continue to change as the key is held down. The key must be released after each change.
- The input shift can be set from − 9 to 9 ° C, in increments of 1 ° C.
**Note: 1.** The default setting is 0 ° C.
**2.** The control output turns OFF while this setting is being made.
|**Input shift display**|**Thermistor measured**<br>**temperature**|**Tempera-**<br>**ture dis-**<br>**play**|
|---|---|---|
|(No shift)<br>(+9°C shift)|25°C<br>25°C|25°C<br>34°C|
## **Setting Direct or Reverse Operation**
**1.** Press the Key for at least 3 s to enter the Direct/Reverse Selection Mode.
**2.** Press the and Keys to set the value. Direct operation can be set by pressing the Key, and reverse operation can be set by pressing the Key.
- **Note: 1.** The default setting is for reverse operation.
**2.** The control output turns OFF while this setting is being made.
|**Direct/reverse operation**|**Display**|
|---|---|
|Reverse operation||
|Direct operation||
**6**
**E5L**
## **Setting Protection**
**1.** Setting Protection (Process Value Display) Press the and Keys simultaneously while the process value is being displayed to change to the setting protection state.
**2.** Setting Protection (Set Temperature Display)
- From the Setting Protection (process value display) Mode, press the and Keys simultaneously to change to the setting protection (set temperature display) state.
**3.** From the Setting Protection (set temperature display) Mode, press the and Keys simultaneously to return to the process value display with no setting protection.
|**Display example**|**Display**|
|---|---|
|Process value display||
|Set temperature display||
- **Note: 1.** Setting protection disables key operations to prevent the settings from being changed accidentally. will be lit while protection is in effect.
**2.** Protection will be maintained even when the power supply is turned OFF and ON.
## **Error Displays and Causes**
## **E5L-A** @
When a thermistor disconnection occurs, the built-in relay operates at the OFF side (when NO contacts are used).
|**Thermistor**|**NO contacts**<br>**(Terminal numbers 8 and 12)**<br>***Heating load**|**NC contacts**<br>**(Terminal numbers 4 and 12)**<br>***Cooling load**|
|---|---|---|
|Disconnection|OFF|ON|
|Short-circuit|OFF|ON|
## **E5L-C** @
When an error occurs, the display shows the error code. Take the necessary measures, referring to the following table.
|**Display**|**Meaning**|**Cause**|**Control output**|
|---|---|---|---|
|FFF (lit)|Overflow|The process value is higher than the set<br>temperature range.|Reverse operation: OFF<br>Direct operation: ON|
|--- (lit)|Underflow|The process value is lower than the set<br>temperature range|Reverse operation: ON<br>Direct operation: OFF|
|FFF (flashing)|Thermistor short-<br>circuited|The thermistor is short-circuited.|Reverse operation: OFF<br>Direct operation: OFF|
|--- (flashing)|Thermistor<br>disconnected|The thermistor is disconnected.|Reverse operation: OFF<br>Direct operation: OFF|
|E11 (lit)|Memoryerror|The thermostat has failed.|OFF|
- **Note: 1.** Errors are not displayed while settings are being changed, except for memory errors. The control output status will be as shown in the above table while the set temperature or hysteresis is being set. The control output will be OFF while the temperature input shift or direct/ reverse operation setting is being set. Key operations will be possible when an error occurs, except for a memory error.
**2.** The setting protection indicator ( ) and set value indicator ("SV") will be continued even when settings are protected, except when a memory error occurs.
**7**
**E5L**
## **Safety Precautions**
## **CAUTION**
Do not touch the terminals while power is being supplied. Doing so may occasionally result in minor injury due to electric shock.
Do not allow pieces of metal, wire clippings, or fine metallic shavings or filings from installation to enter the Product. Doing so may occasionally result in electric shock, fire, or malfunction.
Do not use the Product where subject to flammable or explosive gas. Otherwise, minor injury from explosion may occasionally occur.
Never disassemble, modify, or repair the Product or touch any of the internal parts. Minor electric shock, fire, or malfunction may occasionally occur.
If the output relays are used past their life expectancy, contact fusing or burning may occasionally occur. Always consider the application conditions and use the output relays within their rated load and electrical life expectancy. The life expectancy of output relays varies considerably with the output load and switching conditions.
Tighten the terminal screws to between 0.74 and 0.90 N·m. Loose screws may occasionally result in fire.
Set the parameters and wiring of the Product so that they are suitable for the system being controlled. Unexpected operation may occasionally result in property damage or accidents.
A malfunction in the Product may occasionally make control operations impossible or prevent alarm outputs, resulting in property damage. To maintain safety in the event of malfunction of the Product, take appropriate safety measures, such as installing a monitoring device on a separate line.
## **Precautions for Safe Use**
Be sure to observe the following precautions to prevent failure to operate, malfunction, or adverse effects on the performance and functions of the Thermostat. Not doing so may occasionally result in unexpected events.
**1.** The Product is designed for indoor use only. Do not use the Product outdoors or in any of the following locations.
- Locations directly subject to heat radiated from heating equipment
- Locations subject to water or oil
- Locations subject to direct sunlight
- Locations subject to dust or corrosive gas (in particular, sulfide gas and ammonia gas)
- Locations subject to sudden or extreme temperature changes
- Locations subject to icing or condensation
- Locations subject to vibration or shock
**2.** Use and store the Product within the rated temperature and humidity ranges. Provide forced cooling if required.
**3.** To allow heat to escape, do not block the area around the Product.
**4.** Be sure to wire the Product properly with the correct terminal polarity.
**5.** Use the specified size of crimped terminals for wiring (M3.5, width of 6.8 mm or less). To connect bare wires to the terminals, use copper wires with a gauge of AWG24 to AWG14 (equal to a cross-sectional area of 0.205 to 2.081 mm[2] ). (The stripping length is 5 to 6 mm.) Do not connect more than two wires or two crimp terminals to one terminal. When connecting two wires, they must be of the same size and type.
**6.** Do not connect anything to terminals that are not used.
**7.** Allow as much space as possible between the Thermostat and devices that generate powerful high frequencies or surges. Separate the wiring to the Thermostat from high-voltage or highcurrent lines, and do not place the wiring to the Thermostat in parallel with or in the same wiring paths as power lines.
**8.** Use this Product within the rated load and power supply specifications.
**9.** Turn ON the power supply at least 30 minutes prior to starting control operations.
**10.** A switch or circuit breaker must be provided close to the Thermostat. The switch or circuit breaker must be within easy reach of the operator, and must be marked as a disconnecting means for the Thermostat.
**11.** Do not use paint thinner or similar solvents to clean the Thermostat. Use standard grade alcohol.
**12.** Design the system (e.g., the control panel) considering the 2.5 second of delay between turning ON the Thermostat and stabilization of the Thermostat's output.
**8**
**E5L**
## **Precautions for Correct Use**
## **Mounting the Thermostat**
**1.** Using the PTF14A Socket, PTF14A-E Socket with Finger Protection and PTF-14-PU-L Socket with Push-In Plus technology, mount the Thermostat to the bracket (Y92H-10) that is provided.
## **Other Precautions**
- Do not use the E5L-C @ if the front sheet is peeling or torn.
- Use appropriate tools to disassemble the Thermostat for disposal.
**==> picture [233 x 117] intentionally omitted <==**
**----- Start of picture text -----**<br>
(4.6) (4.6)<br>Mount Brackets Mount Brackets<br>Y92H-10 Y92H-10<br>(98.6) (98.6)<br>E5L+PTF14A E5L+PTFZ-14-E<br>**----- End of picture text -----**<br>
**==> picture [123 x 112] intentionally omitted <==**
**----- Start of picture text -----**<br>
(4.6)<br>Mount Brackets<br>Y92H-10<br>(96)<br>**----- End of picture text -----**<br>
**==> picture [77 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
E5L+PTF-14-PU-L<br>**----- End of picture text -----**<br>
**2.** The structure does not allow the case to be removed. Do not apply excessive force when mounting the Thermostat.
## **Settings**
**1.** E5L-A @ Temperature Dial
- The temperature dial has some backlash. To adjust the temperature more accurately, turn the dial clockwise when adjusting the temperature.
- Do not change the setting of the temperature dial more than 20 times.
- Do not attempt to turn the dial past the range of the setting scale. Applying excessive force may damage the Thermostat.
**2.** E5L-A @ Hysteresis Dial
- This dial can be used to set hysteresis for the ON/OFF operation. Turn the dial clockwise to increase the hysteresis and counterclockwise to reduce the hysteresis. Increase the hysteresis to extend the life of the relay by preventing relay chattering caused by the control output turning ON and OFF frequently.
- Do not change the setting of the temperature dial more than 20 times.
## **Mounting the Thermistor**
- Select a location for the temperature sensor of the thermistor where the temperature distribution of sensing objects will not be changed by installation.
- Insert the temperature sensor as far in as possible.
- When measuring fluid temperature, the thermistor should be installed against the current. Before mounting, take factors such as the bending moment of inertia and vibration into consideration.
- Do not apply mechanical force to the temperature-sensing part of the thermistor.
- The E52-THE @@ Thermistor can be used for applications that require metal protective tubing. Consult with your OMRON representative.
**9**
**MEMO**
**10**
## **Terms and Conditions Agreement**
## **Read and understand this catalog.**
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments.
## **Warranties.**
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
## **Limitation on Liability; Etc.**
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
## **Suitability of Use.**
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
## **Programmable Products.**
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof.
## **Performance Data.**
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
## **Change in Specifications.**
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product.
## **Errors and Omissions.**
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions.
## **Note: Do not use this document to operate the Unit.**
**OMRON Corporation Industrial Automation Company Kyoto, JAPAN**
**Authorized Distributor:**
**Contact: www.ia.omron.com**
## _**Regional Headquarters**_
**OMRON EUROPE B.V.** Wegalaan 67-69, 2132 JD Hoofddorp The Netherlands Tel: (31)2356-81-300/Fax: (31)2356-81-388
**OMRON ASIA PACIFIC PTE. LTD.**
438B Alexandra Road, #08-01/02 Alexandra Technopark, Singapore 119968 Tel: (65) 6835-3011/Fax: (65) 6835-2711
## **OMRON ELECTRONICS LLC**
2895 Greenspoint Parkway, Suite 200 Hoffman Estates, IL 60169 U.S.A. Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
**OMRON (CHINA) CO., LTD.**
Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 200120, China Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
© OMRON Corporation 2009-2022 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice.
**CSM_2_11 Cat. No. H162-E1-08**
0522 (0309)
Updated at June 6, 2026
With a legacy spanning over 80 years, Omron Industrial Automation is a globally recognized leader in the manufacture of advanced industrial control and automation components. Renowned for their reliability and engineering excellence, Omron delivers comprehensive solutions that enhance efficiency, machine safety, and precision across a wide range of manufacturing environments. Our extensive portfolio of Omron products is heavily focused on their industry-leading sensing and switching technologies. We offer a vast selection of sensors, excelling specifically in high-performance proximity sensors, light sensors, and temperature sensors. Complementing this range are robust switching solutions, featuring a deep inventory of power relays, solid-state relays, safety relays, and essential relay accessories designed for demanding operational requirements. Beyond sensing and switching, Omron is highly regarded for its precision automation and process control equipment. Our selection features highly accurate temperature controllers, versatile process controllers, and sophisticated panel displays and instrumentation. To support these fundamental systems, we also supply dependable Omron power supplies, notably AC/DC converters, alongside vital connectivity components like DIN rail terminal blocks to ensure secure, efficient, and complete industrial setups.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →