Image not available
Illustrative purposes only
PSK-6G-5
AC-DC,6 W,5 VDC,SIN OUT,ENCAPSULATED
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: CUI
- Product type: AC / DC PCB Mount Power Supplies
- SVHC: No SVHC (04-Feb-2026)
| Delivery and price | |
|---|---|
| Units per pack | 220 |
| Price | 8.42 € |
| Current stock | 10+ |
| Lead time | 30 days |
**date** 10/10/2025 **page** 1 of 6 ## **SERIES:** PSK-6G **DESCRIPTION:** INTERNAL AC-DC POWER SUPPLY **│** ## **FEATURES** - universal input 90 ~ 264 Vac - high efficiency up to 83% - compact size (1.62 x 0.83 inch) - low no load power consumption (<0.075 W) - certified to IEC/EN/UL 62368-1 - designed to meet IEC/EN 60335-1 - operating temperature -40 ~ 80°C (with derating) - class II - over voltage (OVC II & OVC III) and short-circuit protection - operating altitude 5,000 m - CISPR/FCC Class B |Hols COAL|CE||||| |---|---|---|---|---|---| |**MODEL**|**output**<br>**voltage**|**output**<br>**current**|**output**<br>**power**|**ripple**<br>**and noise1**|**efficiency2**| |||**max**|**max**|**max**|**typ**| ||(Vdc)|(A)|(W)|(mVp-p)|**(%)**| |PSK-6G-3|3.3|1.50|4.95|100|75| |PSK-6G-5|5|1.20|6.0|100|78| |PSK-6G-9|9|0.67|6.0|100|81| |PSK-6G-12|12|0.50|6.0|120|81| |PSK-6G-15|15|0.40|6.0|150|81| |PSK-6G-24|24|0.25|6.0|240|83| - Notes: 1. Ripple & noise are measured at 20 MHz BW with 0.1 µF ceramic capacitor and a 10 µF electrolytic capacitor 2. Typical efficiency at 230 Vac and full load at 25°C. 3. Unless otherwise specified, all indicators in this manual are measured at Ta=25 °C, humidity<75% RH, nominal input voltage, and output rated load. ## **PART NUMBER KEY** ## **- - PSK 6G XX** Base Number Output Voltage **belfuse** .com **CUI Inc │ SERIES:** PSK-6G **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 10/10/2025 **│ page** 2 of 6 |**INPUT**|||||| |---|---|---|---|---|---| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |voltage4|ac input<br>dc input|90<br>120|100~240|264<br>370|Vac<br>Vdc| |frequency||47|50~60|63|Hz| |current|at full load, 100 Vac|||0.25|A| |inrush current|at 240 Vac, cold start at 25°C|||90|A| |leakage current||||0.25|mA| |no load power consumption||||0.075|W| Notes: 4. The safety approvals only apply to the ac input. |**OUTPUT**|||||| |---|---|---|---|---|---| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| ||3.3 Vdc output model|||1,500|μF| ||5 Vdc output model|||1,200|μF| |capacitive load|9 Vdc output model<br>12 Vdc output model|||670<br>500|μF<br>μF| ||15 Vdc output model|||400|μF| ||24 Vdc output model|||250|μF| ||3.3 Vdc output model|||±6|%| |output voltage accuracy|5 & 9 Vdc output model|||±5|%| ||12, 15 & 24 Vdc output model|||±3|%| |line regulation|low line to high line|||±1|%| ||10% ~ 100% load||||| |load regulation|3.3 Vdc output model<br>5 & 9 Vdc output model|||±6<br>±5|%<br>%| ||12, 15 & 24 Vdc output model|||±3|%| |hold-up time|at 115 Vac||12||ms| |switching frequency||30||70|kHz| |**PROTECTIONS**|||||| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |over current protection|auto recovery, hiccup|110||200|%| ||auto recovery, hiccup||||| ||3.3 & 5 Vdc output model|6.45||7.14|Vdc| |over voltage protection|9 Vdc output model<br>12 Vdc output model|10.5<br>14.3||12.1<br>15.8|Vdc<br>Vdc| ||15 Vdc output model|17.1||19.5|Vdc| ||24 Vdc output model|28.5||31.5|Vdc| |short circuit protection|auto recovery||||| |**SAFETY & COMPLIANCE**|||||| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |isolation voltage|input to output, for 1 minute|||4,300|Vac| |safety approvals|certifed to 62368-1: IEC, EN, UL<br>designed to meet 60335-1: IEC, EN||||| |safety class5|Class II (to be determined at end product), IEC/EN/UL|62368-1|||| |EMC emmision|EN 55032:2015+A1:2020, EN 55032:2015+A11:2020<br>EN 61000-6-3:2021, Class B||||| |conducted disturbance|EN 55032:2015+A1:2020, EN 55032:2015+A11:2020<br>EN 61000-6-3:2021, Class B||||| |radiated disturbances|EN 55032:2015+A1:2020, EN 55032:2015+A11:2020<br>EN 61000-6-3:2021, Class B||||| |harmonic current emissions|EN 61000-3-2:2019+A1:2021||||| **belfuse** .com **CUI Inc │ SERIES:** PSK-6G **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 10/10/2025 **│ page** 3 of 6 ## **SAFETY & COMPLIANCE** |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |---|---|---|---|---|---| |voltage fluctuations & flicker|EN 61000-3-3:2013+A2:2021||||| |EMC immunity|EN 55035:2017+A11:2020, EN 61000-6-1:2019, EN 61000-6-2:2019, IEC 61000-4-2,3,4,5,6,11||||| |ESD|IEC 61000-4-2:2008, Air Discharge: ±8 kV, Contact Discharge: ±4 kV, perf. Criteria A||||| |radiated immunity|IEC 61000-4-3:2020, perf. Criteria A||||| |EFT/burst|IEC 61000-4-4:2012, ±1.0 kV, ±2 kV, perf. Criteria A||||| |surge|IEC 61000-4-5:2014+A1:2017, L-N: ±0.5 kV, ±1 kV, perf. Criteria A||||| |conducted disturbance|IEC 61000-4-6:2013+COR1:2015, perf. Criteria A||||| |voltage dips|IEC 61000-4-11:2020, Dip: 30% Reduction, Dip >95% Reduction, perf. Criteria A||||| |voltage interruptions|IEC 61000-4-11:2020, >95% Reduction, perf. Criteria B||||| |MTBF|MIL-HDBK-217F at 25°C|||1,120,000|hours| |RoHS|yes||||| Notes: 5. The UL 623681-1 standard is Ed. 2.0. ## **ENVIRONMENTAL** |**ENVIRONMENTAL**|||||| |---|---|---|---|---|---| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |operating temperature||-40||80|°C| |storage temperature||-40||85|°C| |storage humidity|non-condensing|0||93|%| |operating altitude|IEC/EN/UL 62368-1 OVC II<br>IEC 62368-1 OVC III|||5,000<br>2,000|m<br>m| |**MECHANICAL**|||||| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |dimensions|1.620 x 0.830 x 0.787 [41.1x21.0x20.00 mm]||||inch| |weight|||30||g| ## **MECHANICAL DRAWING** units: inch [mm] tolerance: inch: x.xx=±0.03, x.xxx=±0.020 mm: x.x=±0.7, x.xx=±0.50 |PIN CONNECTIONS|PIN CONNECTIONS| |---|---| |PIN|Function| |1|AC(N)| |2|AC(L)| |3|+Vo| |4|-Vo| **belfuse** .com **CUI Inc │ SERIES:** PSK-6G **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 10/10/2025 **│ page** 4 of 6 ## **DERATING CURVE** ## **EFFICIENCY CURVES** **belfuse** .com **CUI Inc │ SERIES:** PSK-6G **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 10/10/2025 **│ page** 5 of 6 ## **EFFICIENCY CURVES (CONTINUED)** ## **ELECTRICAL BLOCK DIAGRAM** **Figure 1** **belfuse** .com **CUI Inc │ SERIES:** PSK-6G **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 10/10/2025 **│ page** 6 of 6 ## **REVISION HISTORY** |**rev.**|**description**|**date**| |---|---|---| |1.0|initial release|07/22/2025| |1.01|dimensions updated in the features|10/10/2025| The revision history provided is for informational purposes only and is believed to be accurate. **==> picture [155 x 34] intentionally omitted <==** 15575 SW Sequoia Pkwy #100 Portland, OR 97224 800.275.4899 Fax 503.612.2383 Belfuse.com powersupport@belf.com CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
Updated at June 3, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →