Image not available
Illustrative purposes only
PSK-36E-15
AC-DC, 36 W, 15 VDC, CHASSIS MOUNT
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: CUI
- Product type: AC / DC PCB Mount Power Supplies
- SVHC: Lead (21-Jan-2025)
- Product Range: PSK-36E Series
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 21.82 € |
| Current stock | 10+ |
| Lead time | 30 days |
Additional Resources: Product Page | 3D Model | PCB Footprint **date** 12/20/2024 **page** 1 of 6 ## **SERIES:** PSK-36E **DESCRIPTION:** INTERNAL AC-DC POWER SUPPLY **│** ## **FEATURES** - universal input range (90 ~ 264 Vac) - Class B emissions (EN 55032/CISPR) - certified to IEC/EN/UL 62368-1 - designed to meet IEC/EN 60335 - short circuit, over voltage protection - <0.1 W no-load power consumption - Class II, Class I (determined at end use) - 5,000 m operating altitude |**MODEL**|**output**<br>**voltage**|**output**<br>**current**|**output**<br>**power**|**ripple**<br>**and noise1**|**efficiency2**| |---|---|---|---|---|---| ||**typ**|**max**|**max**|**max**|**typ**| ||(Vdc)|(A)|(W)|(mVp-p)|**(%)**| |PSK-36E-5|5|6.0|30|100|85| |PSK-36E-12|12|3.0|36|120|88| |PSK-36E-15|15|2.4|36|150|88| |PSK-36E-24|24|1.5|36|240|89| |PSK-36E-48|48|0.75|36|480|89| - Notes: 1. At full load, nominal input, 20 MHz bandwidth oscilloscope with 0.1µF ceramic capacitor and 10 µF electrolytic capacitor. 2. At 230 Vac input. 3. All specifications are measured at Ta=25°C, humidity <75%, nominal input voltage, and rated output load unless otherwise specified. ## **PART NUMBER KEY** ## **- - PSK 36E XX** Base Number Output Voltage **cui** .com Additional Resources: Product Page | 3D Model | PCB Footprint **CUI Inc │ SERIES:** PSK-36E **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 12/20/2024 **│ page** 2 of 6 |**INPUT**|||||| |---|---|---|---|---|---| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |voltage4|ac input (safety approved)<br>dc input|90<br>120|100~240|264<br>370|Vac<br>Vdc| |frequency||47|50~60|63|Hz| |current|at 100 Vac, full load|||0.9|A| |inrush current|at 240 Vac, full load|||90|A| |leakage current||||0.25|mA| |no load power consumption||||0.1|W| |Notes:<br>4. See the derating curves for more details.|||||| |**OUTPUT**|||||| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| ||5 Vdc output model|||6,000|μF| ||12 Vdc output model|||3,000|μF| |capacitive load|15 Vdc output model|||2,400|μF| ||24 Vdc output model|||1,500|μF| ||48 Vdc output model|||750|μF| ||5 Vdc output model|4.90||5.10|Vdc| ||12 Vdc output model|11.76||12.24|Vdc| |output voltage set point|15 Vdc output model|14.70||15.30|Vdc| ||24 Vdc output model|23.52||24.48|Vdc| ||48 Vdc output model|47.02||48.96|Vdc| |voltage accuracy|5 Vdc output model<br>all other output models||±2<br>±1||%<br>%| |line regulation|high line to low line|||±0.5|%| |load regulation|10 % to 100 % load|||±1.0|%| |hold-up time|at 115 Vac||8||ms| |switching frequency|||65||kHz| |**PROTECTIONS**|||||| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| ||latch mode||||| ||5 Vdc output model|||7.44|Vdc| |over voltage protection|12 Vdc output model<br>15 Vdc output model|||16.8<br>21.5|Vdc<br>Vdc| ||24 Vdc output model|||31.5|Vdc| ||48 Vdc output model|||63.0|Vdc| |over current protection|auto recovery, hiccup|110||180|%| |short circuit protection|auto recovery||||| |**SAFETY & COMPLIANCE**|||||| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |isolation voltage|input to output, for 1 minunte|||4,000|Vdc| |safety approvals|certifed to 62368-1: IEC, EN, UL<br>designed to meet 60335-1: EN||||| |safety class|Class II, Class I (determined at end use)||||| |EMC|EN 55032:2015+A11:2020, EN 61204-3:2018, EN IEC 61000-6-3:2021, EN IEC 61000-6-4:2019,<br>EN IEC 61000-3-2:2019, EN 61000-3-3:2013+A1:2019, Class B||||| |EMC immunity|EN 55035:2017+A11:2020, EN 61204-3:2018, EN IEC 61000-6-1:2019, EN IEC 61000-6-2:2019||||| |conducted emissions|EN 55032:2015+A11:2020, EN 61204-3:2018, EN IEC 61000-6-3:2021, EN IEC 61000-6-4:2019,<br>Class B||||| |radiated emissions|EN 55032:2015+A11:2020, EN 61204-3:2018, EN IEC 61000-6-3:2021, EN IEC 61000-6-4:2019,<br>Class B||||| |ESD|IEC 61000-4-2:2008, perf. Criteria A||||| **cui** .com Additional Resources: Product Page | 3D Model | PCB Footprint **CUI Inc │ SERIES:** PSK-36E **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 12/20/2024 **│ page** 3 of 6 ## **SAFETY & COMPLIANCE** |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |---|---|---|---|---|---| |radiated immunity|IEC 61000-4-3:2020, perf. Criteria A||||| |EFT/burst|IEC 61000-4-4:2012, ±1 kV, ±2 kV, perf. Criteria A||||| |surge|IEC 61000-4-5:2014+A1:2017, L-N: ±0.5 kV, ±1 kV, L-E(Ground): ±0.5 kV, ±1 kV, ±2 kV,<br>perf. Criteria A||IEC 61000-4-5:2014+A1:2017, L-N: ±0.5 kV, ±1 kV, L-E(Ground): ±0.5 kV, ±1 kV, ±2 kV,||| |conducted immunity|IEC 61000-4-6:2013+COR1:2015, perf. Criteria A||||| |PFMF|IEC 61000-4-8:2009, perf. Criteria A||||| |voltage dips|IEC 61000-4-11:2020, Dip: 30% Reduction, Dip >95% Reduction, perf. Criteria A||IEC 61000-4-11:2020, Dip: 30% Reduction, Dip >95% Reduction, perf. Criteria A||| |voltage interruption|IEC 61000-4-11:2020, >95% Reduction, perf. Criteria B||||| |MTBF|as per MIL-HDBK-217F at 25°C|700,000|||hours| |RoHS|yes||||| |**ENVIRONMENTAL**|||||| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |operating temperature|see derating curve<br>(safety approved at maximum 50°C)|-40||80|°C| |storage temperature||-40||85|°C| |storage humidity|non-condensing|0||93|%| |altitude|IEC/EN/UL 62368-1 OVC II<br>designed to meet EN 60335-1 OVC II|||5,000<br>2,000|m<br>m| |**MECHANICAL**|||||| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |dimensions|3.100 x 1.600 x 1.134 [78.8 x 40.7 x 28.80 mm]||||inch| |weight|||156||g| ## **DERATING CURVE** **cui** .com Additional Resources: Product Page | 3D Model | PCB Footprint **CUI Inc │ SERIES:** PSK-36E **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 12/20/2024 **│ page** 4 of 6 ## **MECHANICAL DRAWING** ## units: inch [mm] tolerance: inches: x.xx = ±0.03, x.xxx = ±0.020 mm: x.x - ±0.7, x.xx = ±0.50 |PIN CONNECTIONS|PIN CONNECTIONS| |---|---| |PIN|Function| |1|AC(N)| |2|AC(L)| |3|+Vout| |4|+Vout| |5|-Vout| |6|-Vout| ## **EFFICIENCY CURVES** **cui** .com Additional Resources: Product Page | 3D Model | PCB Footprint **CUI Inc │ SERIES:** PSK-36E **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 12/20/2024 **│ page** 5 of 6 ## **EFFICIENCY CURVES (CONTINUED)** ## **ELECTRICAL BLOCK DIAGRAM** **==> picture [42 x 10] intentionally omitted <==** **----- Start of picture text -----**<br> Figure 1<br>**----- End of picture text -----**<br> **cui** .com Additional Resources: Product Page | 3D Model | PCB Footprint **CUI Inc │ SERIES:** PSK-36E **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 12/20/2024 **│ page** 6 of 6 ## **REVISION HISTORY** |**rev.**|**description**|**date**| |---|---|---| |1.0|initial release|10/15/2024| |1.01|safeties updated|12/20/2024| The revision history provided is for informational purposes only and is believed to be accurate. **==> picture [155 x 34] intentionally omitted <==** ## **Headquarters** 15575 SW Sequoia Pkwy #100 Portland, OR 97224 **800.275.4899** Fax 503.612.2383 **cui** .com techsupport@cui.com CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
Updated at June 3, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →