PSG480E24RM
POWER SUPPLY, AC-DC, 24V, 20A
- Manufacturer: EATON
- Product type:
- Power Supply Applications:ITE; No. of Outputs:1 Output; Output Power Max:480W; Output Voltage - Output 1:24VDC; Output Current - Output 1:20A; Output Voltage - Output 2: 44Y6826
- Product Range: PSG Series
- No. of Outputs: 1 Output
- Output Power Max: 480W
- Current, Output 4: -
- Input Voltage VAC: 85V AC to 264V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 20A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 24VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 5 |
| Price | 375.81 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **Powersupplyunit,1-phase,100-240VAC/24VDC,20A** ## **Partno. PSG480E24RM Articleno. 172894 CatalogNo. PSG480E24RM** ## **Delivery program** |**Deliveryyprogramrogramgramram**|||| |---|---|---|---| |Product range|||Power supplies PSG| |Subrange|||power supply unit| |Description|||Power Boost via 2-fold rated operational current for 2 s<br>PELV (EN 60204), SELV (EN 60950)| |Phases|||Single-phase| |Input voltage range|||85 - 264 V AC<br>(120 - 375 V DC)| |Nominal input voltage|||100 - 240 V AC<br>125 - 250 V DC| |Rated output voltage|||24 V DC (± 2%)| |Rated output current||A|20| |Setting range for the output voltage|||24 - 28 V DC| |Rated output power||W|480| ## **Technicaldata** ## **Inputcharacteristics** ||Nominal input voltage|||100 - 240 V AC| |---|---|---|---|---| |||||125 - 250 V DC| ||Input voltage range||V|85 - 264 V AC| |||||120 - 375 V DC| ||Supply frequency|||| ||Rated value||Hz|50/60| ||Range||Hz|47 - 63| ||Nominal current|In|A|< 5.0 bei 115 V AC| |||||< 3.0 bei 230 V AC| ||Inrush current limitation I²t (+25 °C)||A|< 35 A at 115 V AC| |||||< 35 A at 230 V AC| ||Mains buffering at nominal load||ms|| ||Mains failure bridging||ms|> 20 at 115 V AC| |||||> 125 at 230 V AC| ||Run-up time after mains voltage applied||ms|< 1000| ||Internal input fuse (device protection, not accessible)|||T8 AH/250 V| ||Back-up fuse|||10, 16 A (recommended)| ||Tripping characteristic|||B| ||Leakage Current|||< 3 mA at 240 V AC| ||Short-term interruption|||100% voltage dip, 1 cycle (20 ms at 50 Hz), automatic start| |**Outputcharacteristics**||||| ||Rated output power||W|480| ||Rated output voltage|||24 V DC (± 2%)| ||Tolerance|||±2 %| ||Setting range for the output voltage|||24 - 28 V DC| ||Derating from Tamb> +50 °C|||> 50 °C (2.5% / °C)| |||||> 70 °C (5% / °C)| ||Capacitive load starting|||Max 10000 µF| ||Heat dissipation||W|59| ||Efficiency||%|> 90 at 115 V AC & 230 V AC| ||Residual ripple and switching peaks|||< 50 mVpp / < 150 mVpp| ||Can be switched in parallel|||for redundancy, with O ring diode (PSG960R24RM)| |**Generalcharacteristics**||||| ||Housing|||Aluminium| ||Status indication|||green LED for "DC OK"| ||MTBF (mean time between failures)|||> 500,000 h| ||Height||mm|121| 11/17/2016 172894 - HPL-ED2016 V27.0 EN 1 / 4 |Width||mm|144| |---|---|---|---| |Depth||mm|118.6| |Weight||kg|1.37| |Terminations|||Screw connection| |Stripping length||mm|7| |Terminal capacity|||| |flexible with ferrules/solid||mm2|Primary side: 0.82 - 5.3 mm² (18 - 10 AWG)<br>Secondary side: 3.3 - 5.3 mm² (12 - 10 AWG)| |Tightening torque||Nm|Primary side: 0.5<br>Secondary side: 0.5| |Ambient air temperature range||°C|| |Operation||°C|-20 - +75 (> 50 °C derating)| |Storage, transport|ϑ|°C|| |Storage|ϑ|°C|-25 - +85| |damp heat|||< 95 % relative humidity at +25 °C, no condensation| |Vibrations (IEC/EN 60068-2-6)|||10 - 500 Hz at 30 m/s² (3 G max ) for 60 min. in X-axis, Y-axis, Z-axis directions| |Mechanical shock resistance (IEC 60068-2-27)|||30 g (300 m/s²) in all directions| |Pollution degree|||2| |Climatic class (IEC)|||3K3 according to EN 60721| |**Safetyandsafetyfeatures**|||| |Transient overvoltage protection|||Varistor| |Current limitation at short-circuit|||IÜberstrom= 150 % der max. Ausgangsleistung| |Overvoltage protection|||Yes, against internal overvoltage| |Insulation voltage|||| |Input/Output|||4 kV AC (type test), 3 kV AC (routine test)| |Input/PE|||1.5 kV AC (type test), 1.5 kV AC (routine test)| |Output/PE|||1.5 kV AC (type test), 500 V AC (routine test)| |Degree of Protection|||IP20| |Protection class|||Class I with PE connection| |**Standards**|||| ||||Electrical equipment of machines: IEC60204-1 (Overvoltage category III)<br>Equipping power installations with electronic apparatus: EN 50178/IEC 62103<br>Safety extra-low voltage: PELV (EN 60204), SELV (EN 60950)<br>Protection against electric shock: DIN 57100-410<br>CE: according to EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU<br>RoHS-compliant: RoHS Directive 2011/65/EU<br>ITE: EN 55022, EN 61000-3-2, EN 61000-3-3, EN 55024<br>Industrial: EN 55011<br>Mains harmonics limitation: EN 601000-3-2<br>Electrical Safety (of IT equipment) : SIQ to EN60950-1, UL/c-UL recognized to UL<br>60950-1, CSA C22.2 No. 60950-1, CB scheme to IEC 60950-1<br>UL508<br>Class2: UL/c-UL recognized to UL1310 and CSA C22.2 No. 223 |<br>Component power supply unit for general use: EN61204-3| ## **DesignverificationasperIEC/EN61439** |**DesignverificationasperIEC/EN61439**|||| |---|---|---|---| |Technical data for design verification|||| |Rated operational current for specified heat dissipation|In|A|0| |Heat dissipation per pole, current-dependent|Pvid|W|0| |Equipment heat dissipation, current-dependent|Pvid|W|0| |Static heat dissipation, non-current-dependent|Pvs|W|59| |Heat dissipation capacity|Pdiss|W|0| |Operating ambient temperature min.||°C|-20| |Operating ambient temperature max.||°C|75| |IEC/EN 61439 design verification|||| |10.2 Strength of materials and parts|||| |10.2.2 Corrosion resistance|||Meets the product standard's requirements.| |10.2.3.1 Verification of thermal stability of enclosures|||Meets the product standard's requirements.| |10.2.3.2 Verification of resistance of insulating materials to normal heat|||Meets the product standard's requirements.| |10.2.3.3 Verification of resistance of insulating materials to abnormal heat<br>and fire due to internal electric effects|||Meets the product standard's requirements.| |10.2.4 Resistance to ultra-violet (UV) radiation|||Meets the product standard's requirements.| 11/17/2016 172894 - HPL-ED2016 V27.0 EN 2 / 4 |10.2.5 Lifting|||Does not apply, since the entire switchgear needs to be evaluated.| |---|---|---|---| |10.2.6 Mechanical impact|||Does not apply, since the entire switchgear needs to be evaluated.| |10.2.7 Inscriptions|||Meets the product standard's requirements.| |10.3 Degree of protection of ASSEMBLIES|||Meets the product standard's requirements.| |10.4 Clearances and creepage distances|||Meets the product standard's requirements.| |10.5 Protection against electric shock|||Does not apply, since the entire switchgear needs to be evaluated.| |10.6 Incorporation of switching devices and components|||Does not apply, since the entire switchgear needs to be evaluated.| |10.7 Internal electrical circuits and connections|||Is the panel builder's responsibility.| |10.8 Connections for external conductors|||Is the panel builder's responsibility.| |10.9 Insulation properties|||| |10.9.2 Power-frequency electric strength|||Is the panel builder's responsibility.| |10.9.3 Impulse withstand voltage|||Is the panel builder's responsibility.| |10.9.4 Testing of enclosures made of insulating material|||Is the panel builder's responsibility.| |10.10 Temperature rise|||The panel builder is responsible for the temperature rise calculation. Eaton will<br>provide heat dissipation data for the devices.| |10.11 Short-circuit rating|||Is the panel builder's responsibility.| |10.12 Electromagnetic compatibility|||Is the panel builder's responsibility.| |10.13 Mechanical function|||The device meets the requirements, provided the information in the instruction<br>leaflet (IL) is observed.| ## **TechnicaldataETIM6.0** Low-voltage industrial components (EG000017) / DC-power supply (EC002540) Electric engineering, automation, process control engineering / Power supply / Power supply (other) / DC-power supply (ecl@ss8.1-27-04-90-02 [AFZ644012]) |**TechnicaldataETIM6.0**|**TechnicaldataETIM6.0**|**TechnicaldataETIM6.0**|**TechnicaldataETIM6.0**| |---|---|---|---| |Low-voltage industrial components (EG000017) / DC-power supply (EC002540)|||| |Electric engineering, automation, process control engineering / Power supply / Power supply (other) / DC-power supply (ecl@ss8.1-27-04-90-02 [AFZ644012])|||| |Voltage type of supply voltage|||AC| |1st secondary output voltage||V|24 - 28| |2nd secondary output voltage||V|0 - 0| |3rd secondary output voltage||V|0 - 0| |Max. output current 1||A|20| |Max. output current 2||A|0| |Max. output current 3||A|0| |Secondary voltage adjustable|||Yes| |Nominal value output voltage 1||V|24| |Nominal value output voltage 2||V|0| |Nominal value output voltage 3||V|0| |Nominal value output current 1||A|20| |Nominal value output current 2||A|0| |Nominal value output current 3||A|0| |Short-circuit-proof|||Yes| |Rated supply voltage at AC 50 Hz||V|85 - 264| |Rated supply voltage at AC 60 Hz||V|85 - 264| |Rated supply voltage at DC||V|0 - 0| |Output voltage stabilized|||Yes| |Power consumption||VA|600| |Power output||W|480| |Stabilized|||Yes| |Type of electric connection|||Screw connection| |Rail mounting possible|||Yes| |Wall mounting possible|||No| |Modular version|||Yes| |Width in number of modular spacings|||0| |Built-in width||mm|144| |Built-in height||mm|121| |Direct mounting possible|||No| |Width||mm|144| |Height||mm|121| |Depth||mm|1186| 11/17/2016 172894 - HPL-ED2016 V27.0 EN 3 / 4 |Suitable for safety functions|||No| |---|---|---|---| |SIL according to IEC 61508|||None| |Performance level acc. to EN ISO 13849-1|||None| |Degree of protection (IP)|||IP20| ## **Dimensions** ## **Additionalproductinformation(links)** **IL125009ENInstallationInstructionsforPSG480E24RMPOWERSUPPLY** IL125009EN Installation Instructions for ftp://ftp.moeller.net/DOCUMENTATION/AWA_INSTRUCTIONS/IL125009EN2014_06.pdf PSG480E24RM POWER SUPPLY Eaton Industries GmbH http://www.eaton.eu © 11/2016 by Eaton Industries GmbH 172894 - HPL-ED2016 V27.0 EN 11/17/2016 4 / 4
Updated at June 4, 2026
Eaton is a global leader in power management technologies, providing energy-efficient solutions that help customers effectively manage electrical power safely and sustainably. Renowned in the electronics industry for its deep engineering expertise, the company develops reliable components designed to address the most critical power challenges across the computing, industrial, medical, and transportation sectors. The manufacturer's product portfolio is highly regarded for its robust power and line protection solutions. A core focus of their offering includes high-efficiency AC/DC converters designed for demanding power supply applications. Complementing these are Eaton's advanced passive components, particularly power inductors, which play a critical role in energy storage, filtering, and voltage regulation in modern electronic circuitry. Furthermore, their industry-leading circuit protection lineup features precision thermal circuit breakers built to safeguard sensitive equipment from overcurrent events. Beyond power conversion and protection, Eaton supplies specialized components for broader industrial applications. This includes precision panel instrumentation for automation and process control, as well as dependable power relays for complex switching tasks. Through a steadfast commitment to innovation and quality, Eaton equips engineers with the critical components required to build safe, efficient, and resilient electronic systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →