Image not available
Illustrative purposes only
PSC-100A-C
AC/DC Enclosed Power Supply (PSU), ITE, 1 Outputs, 100.05 W, 13.8 VDC, 7 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC Enclosed Power Supplies
- SVHC: No SVHC (25-Jun-2025)
- Product Range: PSC-100 Series
- No. of Outputs: 1Outputs
- Output Power Max: 100.05W
- Input Voltage VAC: 90V AC to 264V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 7A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 13.8VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 29.41 € |
| Current stock | 10+ |
| Lead time | 30 days |
## 100W Single Output with Battery Charger(UPS Function) **PSC - 100 series** Caen e rere reer reer e eee eee ee ## **SPECIFICATION** BauarSicherheitbeegelodwacmat geprufto ges g As US ~~S|~~ c ~~c~~ s www.ID 2000000000tuv.com FL CBC **UL62368 1- EN62368-1 TPTC004 IEC62368-1** |**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**Note.4**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**ALARM**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**SAFETY STANDARDS**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**BATTERY CUT OFF**<br>**AC OK**<br>**Note.6**<br>**BATTERY LOW**<br>**AC CURRENT (Typ.)**<br>2400ms, 30ms/230VAC 2400ms, 30ms/115VAC at full load<br>40ms/230VAC 14ms/115VAC at full load<br>90 ~ 264VAC 127 ~ 370VDC<br>47 ~ 63Hz<br>86%<br>CH1:28.98 ~ 37.26V<br>88%<br>20 1V<br>±<br>2A/115VAC 1.2A/230VAC<br>COLD START 35A/115VAC 70A/230VAC<br><1mA / 240VAC<br>105 ~ 150% rated output power<br>CH1:14.49 ~ 18.63V<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>Protection type : Shut down o/p voltage, re-power on to recover<br>10 0.5V<br>±<br>UL62368-1, TUV EN62368-1,<br>approved<br>EAC TP TC 004<br>Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020<br>Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A, EAC TP TC 020<br>-20 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>20 ~ 90% RH non-condensing<br>-20 ~ +85<br>, 10 ~ 95% RH<br>℃<br>10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes<br>417.6K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>PCB:127*76.2*31mm (L*W*H) ; Enclosed type:130*85*37mm (L*W*H)<br>PCB:0.23Kg; 63pcs/15.5Kg/1.35CUFT ; Enclosed type:0.44Kg;32pcs/15Kg/0.64CUFT<br>**FUNCTION**<br>Battery low voltage : < 11V<br>Battery low voltage : < 22V<br>Relay contact output, ON : AC OK ; OFF : AC Fail ; Max. rating : 30V / 1A<br>Relay contact output, OFF : Battery OK ; ON : Battery Low ; Max. rating : 30V / 1A<br>**PSC-100B**<br>27.6V<br>CH1<br>2.4A<br>0 ~ 3.5A<br>100.74W<br>100mVp-p<br>CH1: 24 ~ 29V<br>±1.0%<br>±0.5%<br>±0.5%<br>27.6V<br>CH2<br>1.25A<br>--------<br>--------<br>--------<br>--------<br>--------<br>13.8V<br>CH2<br>2.5A<br>--------<br>--------<br>--------<br>--------<br>--------<br>**PSC-100A**<br>13.8V<br>4.75A<br>0 ~ 7A<br>100.05W<br>100mVp-p<br>CH1: 12 ~ 15V<br>±1.0%<br>±0.5%<br>±0.5%<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCE Note.3**<br>**ENVIRONMENT**<br>**PROTECTION**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>**SAFETY &**<br>**EMC**<br>**(Note 4)**<br>、<br>℃<br>℃<br>CH1<br>**OUTPUT NUMBER**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>±<br>℃<br>℃<br>0.03%/<br>(0~50<br>) on CH1 output<br>1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25<br>of ambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance: includes set up tolerance, line regulation and load regulation.<br>4. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.<br>5. Heat sink HS2,HS3 can not be shorted.<br>6. Heat sink HS2,HS3 must have safety isolation distance from system case.<br>7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a230mm*230mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)<br>8. Please refer to suggest application (2)<br>(4) in page 3.<br>9. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>=/1000m with fan models for operating altitude higher than 2000m(6500ft)|**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**Note.4**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**ALARM**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**SAFETY STANDARDS**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**BATTERY CUT OFF**<br>**AC OK**<br>**Note.6**<br>**BATTERY LOW**<br>**AC CURRENT (Typ.)**<br>2400ms, 30ms/230VAC 2400ms, 30ms/115VAC at full load<br>40ms/230VAC 14ms/115VAC at full load<br>90 ~ 264VAC 127 ~ 370VDC<br>47 ~ 63Hz<br>86%<br>CH1:28.98 ~ 37.26V<br>88%<br>20 1V<br>±<br>2A/115VAC 1.2A/230VAC<br>COLD START 35A/115VAC 70A/230VAC<br><1mA / 240VAC<br>105 ~ 150% rated output power<br>CH1:14.49 ~ 18.63V<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>Protection type : Shut down o/p voltage, re-power on to recover<br>10 0.5V<br>±<br>UL62368-1, TUV EN62368-1,<br>approved<br>EAC TP TC 004<br>Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020<br>Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A, EAC TP TC 020<br>-20 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>20 ~ 90% RH non-condensing<br>-20 ~ +85<br>, 10 ~ 95% RH<br>℃<br>10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes<br>417.6K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>PCB:127*76.2*31mm (L*W*H) ; Enclosed type:130*85*37mm (L*W*H)<br>PCB:0.23Kg; 63pcs/15.5Kg/1.35CUFT ; Enclosed type:0.44Kg;32pcs/15Kg/0.64CUFT<br>**FUNCTION**<br>Battery low voltage : < 11V<br>Battery low voltage : < 22V<br>Relay contact output, ON : AC OK ; OFF : AC Fail ; Max. rating : 30V / 1A<br>Relay contact output, OFF : Battery OK ; ON : Battery Low ; Max. rating : 30V / 1A<br>**PSC-100B**<br>27.6V<br>CH1<br>2.4A<br>0 ~ 3.5A<br>100.74W<br>100mVp-p<br>CH1: 24 ~ 29V<br>±1.0%<br>±0.5%<br>±0.5%<br>27.6V<br>CH2<br>1.25A<br>--------<br>--------<br>--------<br>--------<br>--------<br>13.8V<br>CH2<br>2.5A<br>--------<br>--------<br>--------<br>--------<br>--------<br>**PSC-100A**<br>13.8V<br>4.75A<br>0 ~ 7A<br>100.05W<br>100mVp-p<br>CH1: 12 ~ 15V<br>±1.0%<br>±0.5%<br>±0.5%<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCE Note.3**<br>**ENVIRONMENT**<br>**PROTECTION**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>**SAFETY &**<br>**EMC**<br>**(Note 4)**<br>、<br>℃<br>℃<br>CH1<br>**OUTPUT NUMBER**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>±<br>℃<br>℃<br>0.03%/<br>(0~50<br>) on CH1 output<br>1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25<br>of ambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance: includes set up tolerance, line regulation and load regulation.<br>4. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.<br>5. Heat sink HS2,HS3 can not be shorted.<br>6. Heat sink HS2,HS3 must have safety isolation distance from system case.<br>7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a230mm*230mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)<br>8. Please refer to suggest application (2)<br>(4) in page 3.<br>9. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>=/1000m with fan models for operating altitude higher than 2000m(6500ft)|**PSC-100A**|**PSC-100A**|**PSC-100B**|**PSC-100B**| |---|---|---|---|---|---| ||**OUTPUT NUMBER**|CH1|CH2|CH1|CH2| ||**DC VOLTAGE**|13.8V|13.8V|27.6V|27.6V| ||**RATED CURRENT**|4.75A|2.5A|2.4A|1.25A| ||**CURRENT RANGE**|0 ~ 7A|--------|0 ~ 3.5A|--------| ||**RATED POWER**|100.05W||100.74W|| ||**RIPPLE & NOISE (max.) Note.2**|100mVp-p|--------|100mVp-p|--------| ||**VOLTAGE ADJ. RANGE**|CH1: 12 ~ 15V||CH1: 24 ~ 29V|| ||**VOLTAGE TOLERANCE Note.3**|±1.0%|--------|±1.0%|--------| ||**LINE REGULATION**|±0.5%|--------|±0.5%|--------| ||**LOAD REGULATION**|±0.5%|--------|±0.5%|--------| ||**SETUP, RISE TIME**<br>**Note.4**|2400ms, 30ms/230VAC 2400ms, 30ms/115VAC at full load|||| ||**HOLD UP TIME (Typ.)**|40ms/230VAC 14ms/115VAC at full load|||| ||**VOLTAGE RANGE**|90 ~ 264VAC 127 ~ 370VDC|||| ||**FREQUENCY RANGE**|47 ~ 63Hz|||| ||**EFFICIENCY (Typ.)**|86%||88%|| ||**AC CURRENT (Typ.)**|2A/115VAC 1.2A/230VAC|||| ||**INRUSH CURRENT (Typ.)**|COLD START 35A/115VAC 70A/230VAC|||| ||**LEAKAGE CURRENT**|<1mA / 240VAC|||| ||**OVERLOAD**|105 ~ 150% rated output power<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed|||| ||**OVER VOLTAGE**|CH1:28.98 ~ 37.26V<br>CH1:14.49 ~ 18.63V<br>Protection type : Shut down o/p voltage, re-power on to recover|||| ||**BATTERY CUT OFF**|10 0.5V<br>±||20 1V<br>±|| ||**AC OK**<br>**Note.6**|Relay contact output, ON : AC OK ; OFF : AC Fail ; Max. rating : 30V / 1A|||| ||**BATTERY LOW**|Battery low voltage : < 11V<br>Battery low voltage : < 22V<br>Relay contact output, OFF : Battery OK ; ON : Battery Low ; Max. rating : 30V / 1A|||| ||**WORKING TEMP.**|-20 ~ +70<br>(Refer to "Derating Curve")<br>℃|||| ||**WORKING HUMIDITY**|20 ~ 90% RH non-condensing|||| ||**STORAGE TEMP., HUMIDITY**|-20 ~ +85<br>, 10 ~ 95% RH<br>℃|||| ||**TEMP. COEFFICIENT**|±<br>℃<br>℃<br>0.03%/<br>(0~50<br>) on CH1 output|||| ||**VIBRATION**|10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes|||| ||**SAFETY STANDARDS**|UL62368-1, TUV EN62368-1,<br>approved<br>EAC TP TC 004|||| ||**WITHSTAND VOLTAGE**|I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC|||| ||**ISOLATION RESISTANCE**|I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃|||| ||**EMC EMISSION**|Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020|||| ||**EMC IMMUNITY**|Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A, EAC TP TC 020|||| ||**MTBF**|417.6K hrs min. MIL-HDBK-217F (25<br>)<br>℃|||| ||**DIMENSION**|PCB:127*76.2*31mm (L*W*H) ; Enclosed type:130*85*37mm (L*W*H)|||| ||**PACKING**<br>PCB:0.23Kg; 63pcs/15.5Kg/1.35CUFT ; Enclosed type:0.44Kg;32pcs/15Kg/0.64CUFT<br>、<br>℃<br>℃<br>1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25<br>of ambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance: includes set up tolerance, line regulation and load regulation.<br>4. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.<br>5. Heat sink HS2,HS3 can not be shorted.<br>6. Heat sink HS2,HS3 must have safety isolation distance from system case.<br>7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a230mm*230mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)<br>8. Please refer to suggest application (2)<br>(4) in page 3.<br>9. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>=/1000m with fan models for operating altitude higher than 2000m(6500ft)||||| 、 ℃ /1000m with fanless models and of 5 ℃ = /1000m with fan models for operating altitude higher than 2000m(6500ft) _File Name:PSC-100-SPEC 2019-07-03_ ## MEAN WELL 100W Single Output with Battery Charger(UPS Function) **PSC - 100 series** ~~a~~ ## **Mechanical Specification** **==> picture [499 x 650] intentionally omitted <==** **----- Start of picture text -----**<br> Unit:mm<br>B<br>Cover:<br>No. 946B-T<br>io M2 © ee e<br>T3.15A/250VAC FUSE CN2 12 <A] O00OOGHOGOSSO0G Gs SSeeeSea eeSees~— 9909900<br>FS13 L 34 =) 00gOGCOGLOD006g806ROOGEOG00og80ogGsRA1906HSLOGSLOGH LOOG909 95005000240p02<br>2 5<br>1 6 Ce<br>CN1 7<br>8<br>@<br>1<br>2<br>3 CN3<br>4<br>M1 ~ ~ Ny SVR1 L<br>HS2 HS3<br>s ® QO® « —_<br>M3<br>5.6 115.8 Mylar film<br>ee Sa a IK<br>127<br>TT = SS yu amas»<br>~<br>| 7<br>& [=]<br>— ~ —_<br>L-Bracket:<br>No. 946A-D SseSS<br>AC Input Connector (CN1) : JST B3P-VH or equivalent<br>Pin No. Assignment Mating Housing Terminal<br>1 AC/N Alarm Output Connector(CN3) : JST B4B-XH or equivalent<br>2 No Pin JST VHR JST SVH-21T-P1.1 Pin No. Assignment Mating Housing Terminal<br>or equivalent or equivalent<br>3 AC/L 1 2<br>AC OK<br>JST XHP JST SXH-001T-P0.6<br>fa | |<br>DC Output Connector (CN2) : JST B8P-VH or equivalent 3 4 Bat. Low or equivalent or equivalent<br>Pin No. Assignment Mating Housing Terminal lal; |<br>1,2 -V<br>3,4 +V JST VHR JST SVH-21T-P1.1 1.HS2,HS3 cannot be shorted.<br>5,6 Bat+ or equivalent or equivalent<br>2.HS2,HS3 must have safety isolation distance from system case.<br>7,8 Bat- 3.-V and Bat- can not be shorted.<br>a : Grounding Required 4.M1 is safety ground. For better EMC performance,Please secure<br>an electrical connection between M1,M2,M3,and chassis grounding.<br>a Block Diagram<br>RL1 AC OK<br>ALARM<br>CIRCUIT O<br>RL2 Bat. Low<br>O<br>EMI FILTER POWER RECTIFIERS +V<br>I/P & &<br>RECTIFIER SWITCHING ee ee ee -V<br>FILTER<br>[fe O Bat. +<br>DETECTION Bat. -<br>FG CIRCUIT<br>PWM<br>O.L.P. CONTROL Battery Charger<br>—I q e —- &<br>= x O.V.P. a Back up Control<br>7.1<br>2-M3 L=4<br>115.8<br>2-M3<br>6-M3 L=4<br>78<br>130 62<br>26<br>17<br>68.6<br>41.7<br>8.2<br>85<br>4-<br>£3.8<br>3max.<br>5.7<br>76.2 64.75<br>31max. 18<br>37<br>**----- End of picture text -----**<br> _File Name:PSC-100-SPEC 2019-07-03_ ## 100W Single Output with Battery Charger(UPS Function) **PSC - 100 series** **==> picture [463 x 181] intentionally omitted <==** **----- Start of picture text -----**<br> Output Derating Output Derating VS Input Voltage<br>100<br>100<br>PCB only<br>90<br>80 80 PCB only<br>Enclosed tpye Enclosed type<br>60 70<br>50<br>60<br>40<br>50<br>20<br>40<br>-20 0 10 20 30 40 50 60 70 (HORIZONTAL) 90 95 100 115 120 140 160 180 200 220 240 264<br>AMBIENT TEMPERATURE ( ¢ ) INPUT VOLTAGE (VAC) 60Hz<br>LOAD (%) LOAD (%)<br>**----- End of picture text -----**<br> ## **Suggested Application** ## **1.Backup connection for AC interruption** - (1) Please refer to the Fig1.1 for suggested connection. The power supply charges the battery and provides energy to the load at the same time when the AC main is OK. The battery starts to supply power to the load when the AC mains fails. **==> picture [61 x 64] intentionally omitted <==** **==> picture [70 x 70] intentionally omitted <==** **==> picture [104 x 78] intentionally omitted <==** **----- Start of picture text -----**<br> -V - Load<br>+V +<br>Bat+<br>Bat- A : 12V<br>+ B : 24V<br>-<br>Battery<br>**----- End of picture text -----**<br> Fig 1.1 Suggested system connection ## **2.Alarm signal for AC OK and Battery Low** (1) Alarm signal is sent out through " AC OK " & " Battery Low " pins.(relay contact type) (2) An external voltage source is required for this function. The maximum applied voltage is 30V and the maximum sink current is 1A. - (3) Table2.1 explains the alarm function built in the power supply |Function|Output of Alarm<br>Description|AC OK|(Battery low)||| |---|---|---|---|---|---| ||Low or short<br>The signal is "Low" when the power supply<br>turns on|CN3 Pin1(Pin3)|||| |AC OK|||||| |Battery<br>Low|voltage 30V max.)<br>voltage 30V max.)<br>Low or short<br>High or open(External applied<br>High or open(External applied<br>The signal is "Low" when the voltage of<br>The signal is "High" when the voltage of<br>The signal turns to be "High" when the power<br>battery is under A:11V, B:22V<br>battery is above A:11V, B:22V<br>supply turns OFF||||R<br>V| |||CN3 Pin2(Pin4)|||External voltage source (V)| ||Table 2.1 Explanation of Alarm Signal||||and resistor (R)| ||||||(The max. Sink is 1A and 30V)| - (4) RL1 (AC OK)signal will go into hiccup mode when the overload protection is activating. **==> picture [126 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> Fig 2.2 Internal circuit of AC OK (Battery Low)<br>**----- End of picture text -----**<br> _File Name:PSC-100-SPEC 2019-07-03_
Updated at June 6, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →