PS5R-VB05
AC/DC DIN Rail Power Supply (PSU), ITE, 1 Output, 10 W, 5 VDC, 2 A
- Manufacturer: IDEC
- Product type:
- SVHC: No SVHC (15-Jan-2019)
- Product Range: PS5R-V Series
- No. of Outputs: 1 Output
- Output Power Max: 10W
- Current, Output 4: -
- Input Voltage VAC: 85V AC to 264V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 2A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 5VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 43.01 € |
| Current stock | 10+ |
| Lead time | 30 days |
Switching Power Supplies ## PS5R-V ## Suitable for global and semiconductor applications ## Meets SEMI F47 Sag Immunity Voltage sag ride-through capabilities for semiconductor process equipment, metering equipment and automatic test equipment. (approved at 208V AC input) ## Space-saving DIN-rail switching power supplies. • See website for details on approvals and standards. |Part No.|Input Voltage|Output Capacity|Output Voltage / Output Current| |---|---|---|---| |PS5R-VB05||10W|5V/2.0A| |PS5R-VB12|||12V/1.3A| |||15W|| |PS5R-VB24|||24V/0.65A| |PS5R-VC12|||12V/2.5A| |||30W|| |PS5R-VC24|||24V/1.3A| |PS5R-VD24||60W|24V/2.5A| |PS5R-VE24||90W|24V/3.75A| ||100 to 240V AC||| ||(Voltage range: 85 to 264V AC /||| ||100 to 370V DC)||| |PS5R-VF24||120W|24V/5.0A| |PS5R-VG24||240W|24V/10.0A| For more information, visit http://asia.idec.com J-003 ## Reduced installation space <2 an ## Conventional - Required space between the switching power supplies reduced to half ## Volume: - Size is reduced to the smaller output capacity (30W/90W/120W)[*1] Approx.50% less*2 Width: Approx.50% less*2 ## Reduced wiring & flexible installation - Less wiring required - Can be installed in six directions ## Improved reliability - Five-year warranty - Operating temperature –25 to +75ºC - *1 Compared with conventional PS5R-S model. - *2 Compared with conventional PS5R-S output capacity 30W model. ## Reduces installation space inside the panel APEM Switches & Pilot Lights Control Boxes Emergency Stop Switches Enabling Switches Safety Products Explosion Proof Terminal Blocks Relays & Sockets Circuit Protectors Power Supplies LED Illumination Controllers Operator Interfaces Sensors AUTO-ID PS5R-S s nw] YU 20mm 20mm PS5R-V Slim size Space between the switching supplies reduced to half ae ~~[~~ | U U 10mm 10mm PS5R-V PS6R ## Reduced wiring & flexible installation ## Reduced wiring ## Six mounting directions Spring-up terminals accepts wiring of ring terminals. No need to worry about loosing screws . Download catalogs and CAD from http://asia.idec.com/downloads J-004 ## PS5R-V Switching Power Supplies ## Space-saving DIN-rail switching power supplies ## PS5R-V Package Quantity: 1 APEM Switches & Pilot Lights Shape Control Boxes on a es I 240, . Emergency Stop Switches Enabling 10W/15W 30W 60W/90W 120W 240W Switches ~~Sn~~ Safety Products ~~YG~~ Output Capacity Part No. Input Voltage Output Voltage Output Current ~~a~~ 10W PS5R-VB05 ~~ee~~ 5V 2.0 A Explosion Proof PS5R-VB12 12V 1.3 A 15W PS5R-VB24 24V 0.65A Terminal Blocks ~~| Er~~ ~~**ee**~~ PS5R-VC12 12V 2.5 A Relays & Sockets 30W PS5R-VC24 100 to 240V AC 24V 1.3 A ~~fpoe EF~~ (Voltage range: 85 to 264V AC / 100 to 370V DC) ~~**ee**~~ Circuit 60W PS5R-VD24 24V 2.5 A Protectors ~~es ee~~ 90W PS5R-VE24 24V 3.75A Power Supplies ~~es~~ 120W PS5R-VF24 ~~ee~~ 24V 5.0 A ~~L_TdITDC_c—.-es~~ LED Illumination 240W PS5R-VG24 24V 10.0 A ~~es ee~~ Controllers Operator Interfaces Sensors AUTO-ID PS5R-V ~~= _~~ PS6R ## DIN Rail (35mm-wide) |Length||Part No.<br>Material<br>Weight|Part No.<br>Material<br>Weight|Package Quantity|Package Quantity|Remarks|Remarks| |---|---|---|---|---|---|---|---| |1,000mm|BAA1000PN10<br>Aluminum<br>BAP1000PN10<br>Steel||200g<br>320g||10<br>10|SeeH-071for DIN rail products.|| |End Clip|||||||| |Part No.<br>Package Quantity<br>BNL6PN10<br>10<br>Panel Mounting Bracket *1<br>Applicable Switching<br>Power Supply<br>Ordering No.<br>PS5R-VB<br>PS9Z-5R1B|||Remarks<br>Applicable rail: BAA,BAP<br>Weight: approx.15g<br>Remarks<br>—||Part No. Development<br>PS5R-V <br>Switching Power<br>Supply<br>Slim Line<br>~~oe~~<br>: :||Output Voltage Code<br>05: 5V *4<br>12: 12V *5<br>24: 24V<br>Output Capacity| |PS5R-VC||PS9Z-5R2B|For side mounting||||Code| |PS5R-VD<br>PS5R-VE||PS9Z-5R1C|—||||B: 10W/15W<br>C: 30W| |PS5R-VF<br>PS5R-VG||PS9Z-5R1E<br>PS9Z-6R1F<br>PS9Z-6R2F|—<br>—<br>For side mounting||Use for interpreting part numbers.||D: 60W<br>E: 90W<br>F: 120W<br>G: 240W| ## End Clip ## Panel Mounting Bracket *[1] |Applicable Switching<br>Power Supply|Ordering No.|Remarks| |---|---|---| |PS5R-VB<br>PS5R-VC|PS9Z-5R1B|—| ||PS9Z-5R2B|For side mounting| |PS5R-VD<br>PS5R-VE|PS9Z-5R1C|—| |PS5R-VF|PS9Z-5R1E|—| |PS5R-VG|PS9Z-6R1F|—| ||PS9Z-6R2F|For side mounting| - *1: Used for direct panel mounting. - *4: PS5R-VB only *5: PS5R-VB/VC only For more information, visit http://asia.idec.com J-005 PS5R-V Switching Power Supplies APEM Switches & Pilot Lights Control Boxes Emergency Stop Switches Enabling Switches Safety Products Explosion Proof Terminal Blocks Relays & Sockets Circuit Protectors Power Supplies LED Illumination Controllers Operator Interfaces Sensors AUTO-ID PS5R-V PS6R ## Specifications **==> picture [495 x 666] intentionally omitted <==** **----- Start of picture text -----**<br> (10W/15W)<br>Part No. PS5R-VB05 PS5R-VC12(30W) (60W) (90W) (120W) (240W)<br>PS5R-VB12 PS5R-VD24 PS5R-VE24 PS5R-VF24 PS5R-VG24<br>PS5R-VC24<br>PS5R-VB24<br>Rated Input Voltage 100 to 240V AC<br>(Single-phase two-wire)(*1,*2) (Voltage range: 85 to 264V AC/100 to 370V DC) (Load ≤ 80% at 100-105V DC)<br>Frequency 50/60 Hz<br> 5V: 0.25A<br>100V AC 0.7A 1.3A 1.1A 1.4A 2.7A<br>Input 12V, 24V: 0.35A<br>Current (Typ.) 230V AC 5V: 0.14A 0.3A 0.8A 0.6A 0.7A 1.2A<br>12V, 24V: 0.19A<br>14A max.<br>Inrush 100V AC 18A (Ta = 25°C, cold start) (Ta = 25°C, cold start)<br>Current (Typ.) 230V AC 45A (Ta = 25°C, cold start) 30A max. (Ta = 25°C, cold start)<br>Leakage 120V AC 0.5 mA max.<br>Current 230V AC 1.0 mA max.<br>Efficiency 100V AC 5V: 77%, 12V: 82%, 24V: 84% 12V: 83%, 24V: 85% 86% 88% 89%<br>(Typ.)<br>(at rated 230V AC 5V: 73%, 12V: 80%, 24V: 81% 12V: 85%, 24V: 87% 86% 89% 90%<br>output) (*3)<br>Power 100V AC — — — 0.99<br>Factor (Typ.) 230V AC — — — 0.86 0.92 0.96<br>Rated Voltage/Current 5V/2.0A (*4), 12V/1.3A, 24V/0.65A 12V/2.5A, 24V/1.3A 24V/2.5A 24V/3.75A 24V/5A 24V/10A<br>Adjustable Voltage Range ±10% ±5% ±10%<br> 5V: 53ms<br>12V: 13ms<br>Output Holding 100V AC 12V: 34ms 24V: 15ms 13ms 20ms 30ms 30ms<br>Time (Typ.) 24V: 36ms<br>(at rated 5V: 330ms 12V: 110ms<br>output) 230V AC 12V: 215ms 24V: 110ms 105ms 30ms 33ms 40ms<br>24V: 230ms<br>Start Time<br>500 ms max. 600 ms max. 800 ms max. 700 ms max. 800 ms max.<br>(at rated input and output)<br>Rise Time 5V, 12V: 200ms max. 200ms max.<br>(at rated input and output) 24V: 250ms max.<br>Input Fluctuation 0.4% max.<br>5V: 2.5% max.<br>Load Fluctuation 1.0% max.<br>12V, 24V: 1.0% max.<br>0.05%/°C max. 12V: 0.05%/°C max. (–10 to +50°C)<br>Temperature Change (–10 to +65°C) 24V: 0.05%/°C max. (–10 to +55°C) [0.05%/°C max. (–10 to +55°C)] 0.05%/°C max. (–25 to +55°C)<br> 5V: 8% p-p max. (–25 to –10°C)<br>12V: 6% p-p max. (–25 to –10°C)<br>12V: 6% p-p max. (–25 to –10°C)24V: 4% p-p max. (–25 to –10°C) 24V: 4% p-p max. (–25 to –10°C) [4% p-p max. (–25 to –10°C)] 4% p-p max. (–25 to –10°C)<br> 5V: 5% p-p max. (–10 to +0°C)<br>Ripple 12V: 2.5% p-p max. (–10 to +0°C)<br>(including noise) 12V: 2.5% p-p max. (–10 to +0°C)24V: 1.5% p-p max. (–10 to +0°C) 24V: 1.5% p-p max. (–10 to +0°C) [1.5% p-p max. (–10 to +0°C)] 1.5% p-p max. (–10 to +0°C)<br> 5V: 2.5% p-p max. (0 to +65°C)<br>12V: 1.5% p-p max. (0 to +50°C)<br>12V: 1.5% p-p max. (0 to +65°C) 1% p-p max. (0 to +55°C) 1% p-p max. (0 to +55°C)<br>24V: 1% p-p max. (0 to +65°C) 24V: 1% p-p max. (0 to +55°C)<br>Supple-mentary Overcurrent Protection 105% min. (auto reset) 101% min. (auto reset) 105% min. (auto reset)<br>Functions Operation Indicator LED (green)<br>Between input and output terminals: 3,000V AC, 1 minute<br>Dielectric Strength Between input and ground terminals: 2,000V AC, 1 minute<br>Between output and ground terminal: 500V AC, 1 minute<br>Insulation Resistance Between input and output terminals: 100MΩ min. (500V DC megger), Between input and ground terminal: 100MΩ min. (500V DC megger)<br>Operating Temperature (*2) –25 to +75°C (no freezing) –25 to +70°C (no freezing) –25 to +65°C (no freezing)<br>Operating Humidity 20 to 90% RH (no condensation)<br>Storage Temperature –25 to +75°C (no freezing)<br>Storage Humidity 20 to 90% RH (no condensation)<br>10 to 55 Hz, amplitude<br>0.21mm, 2 hours each in 3<br>10 to 55 Hz, amplitude<br>10 to 55 Hz, amplitude 0.33mm, 2 hours each in 3 axes axes (when used with part<br>10 to 55 Hz, amplitude 0.375mm, 0.375mm, 2 hours each<br>Vibration Resistance 2 hours each in 3 axes (when used with part no. BNL6 mounting clips) no. BNL6 mounting clips) in 3 axes<br>10 to 55 Hz, amplitude 0.375mm, 2 hours each in 3 axes 10 to 55 Hz, amplitude<br>(when used with part no. BNL6 mounting clips) (when used with part no.<br>(when used with part no. BNL8 mounting clips) 0.375mm, 2 hours each in<br>BNL6 mounting clips)<br>3 axes (when used with part<br>no. BNL8 mounting clips)<br>Shock Resistance 300 m/s [2] , 3 times each in 6 directions<br>EMI EN61204-3 (Class B)<br>EMC<br>EMS EN61204-3 (industrial)<br>UL508 (Listing), ANSI/ISA-12.12.01, CSA C22.2 No. 107.1, 213,<br>UL508 (Listing), UL1310 Class 2, ANSI/ISA-12.12.01, CSA C22.2 No. 107.1, 213, 223<br>Safety Standards EN60950-1, EN62368-1, EN50178, EN62477-1,<br>EN60950-1, EN62368-1, EN50178, EN62477-1, SELV (UL60950-1, EN60950-1, EN62368-1) SELV (EN60950-1, EN62368-1)<br>Other Standard SEMI F47 (at 208V AC input only)<br>Degree of Protection IP20 (EN60529)<br>Dimensions (mm) 90H × 22.5W × 95D 95H × 36W × 108D 115H × 46W × 121D 125H × 60W × 125D<br>Weight (approx.) 140g 150g 260g 310g 470g 960g<br>Terminal Screw M3.5<br>Input<br>Output<br>Regulation<br>**----- End of picture text -----**<br> At normal temperature and humidity unless otherwise specified. *1: DC input voltage is not subject to safety standards. When using on DC input, connect a fuse to the input terminal for DC input protection. - *2: See the output derating curves on J-008. *3: Under stable state. - *4: PS5R-VB05 (5V DC/2.0A) is 10W (Up to 3.0A at Ta = 0 to 40°C. Not subject to safety standards at 2.0A and over.) ## Reference Value Expected Life (*5) 8 years minimum (at the rated input, 50% load, operating temperature +40°C, standard mounting direction) - *5: Calculation of the expected life is based on the actual life of the aluminum electrolytic capacitor. The expected life depends on operating conditions. Download catalogs and CAD from http://asia.idec.com/downloads J-006 PS5R-V Switching Power Supplies ## Block Diagrams ## PS5R-VB **==> picture [386 x 541] intentionally omitted <==** **----- Start of picture text -----**<br> Fuse<br>L +V<br>INPUT<br>N −V<br>Control<br>APEM V.ADJ<br>Switches &<br>Detection<br>Pilot Lights<br>Control Boxes<br>PS5R-VC/PS5R-VD<br>Emergency<br>Stop Switches<br>Enabling L Fuse +V<br>Switches<br>INPUT<br>Safety Products N −V<br>Explosion Proof<br>V.ADJ<br>Terminal Blocks<br>Detection<br>Relays & Sockets<br>Circuit<br>Protectors PS5R-VE24<br>Power Supplies<br>Fuse<br>LED Illumination L +V<br>INPUT<br>Controllers N −V<br>Operator<br>Interfaces<br>V.ADJ<br>Sensors<br>Detection<br>AUTO-ID<br>PS5R-VF24<br>Fuse<br>PS5R-V<br>L +V<br>INPUT<br>PS6R<br>N −V<br>V.ADJ<br>Detection<br>PS5R-VG24<br>Fuse<br>L +V<br>INPUT<br>N −V<br>V.ADJ<br>Detection<br>Line filter Rectifying Overcurrent Detection Switching Rectifying<br>Line filter Rectifying Overcurrent Detection Switching Rectifying<br>Control<br>Line filter Rectifying Active Filter Ripple Filter Switching Rectifying Overcurrent Detection<br>Control<br>Line filter Rectifying Active Filter Ripple Filter Overcurrent Detection Switching Rectifying<br>Control<br>Line filter Rectifying Active Filter Ripple Filter Switching Rectifying Overcurrent Detection<br>Control<br>**----- End of picture text -----**<br> For more information, visit http://asia.idec.com J-007 PS5R-V Switching Power Supplies PS5R-V PS6R ## Characteristics ## Operating Temperature vs. Output Current (Derating Curves) Conditions: Natural air cooling (Operating temperature is the temperature around the switching power supply.) ## PS5R-VB05, -VB12, -VB24 **==> picture [491 x 400] intentionally omitted <==** **----- Start of picture text -----**<br> PS5R-VB05, -VB12, -VB24 PS5R-VC12 PS5R-VC24<br>10090 Mounting A 10090 Mounting A 10090 Mounting A, B<br>80 Input Voltage: 80 Input Voltage: 80 Input Voltage:<br>70 85-100V AC 70 85-100V AC 70 85-100V AC<br>60 60 60<br>50 50 50 MountingC<br>40 40 40<br>30 Mounting B, C, D, E, F 30 30<br>20 20 Mounting B, C, D, E, F 20 Mounting D, E, F<br>10 10 10<br>0 0 0<br>-30 -20 -10 0 10 20 30 40 50 60 70 80 -30 -20 -10 0 10 20 30 40 50 60 70 80 -30 -20 -10 0 10 20 30 40 50 60 70 80<br>Operating Temperature (˚C) Operating Temperature (˚C) Operating Temperature (˚C)<br>PS5R-VD24 PS5R-VE24 PS5R-VF24<br>100 100 100<br>90 Mounting E 90 Mounting A 90 Mounting C, E<br>8070 : Input Voltage: 85-100V AC 8070 Mounting E 8070<br>60 Mounting B, C, D 60 60 Mounting<br>50 50 50 B, D<br>40 40 40<br>3020 Mounting F Mounting A 3020 B, C, D, FMounting 3020 Mounting F Mounting A<br>10 10 10<br>0 0 0<br>-30 -20 -10 0 10 20 30 40 50 60 70 80 -30 -20 -10 0 10 20 30 40 50 60 70 80 -30 -20 -10 0 10 20 30 40 50 60 70 80<br>Operating Temperature (˚C) Operating Temperature (˚C) Operating Temperature (˚C)<br>PS5R-VG24<br>Operating Temperature Approved by Safety Standards (°C)<br>100 Mounting A<br>90 UL508, CSA C22.2 No.107.1, ANSI/ISA12.12.01,<br>80 Mounting E EN60950-1, EN62368-1, EN50178, EN62477-1<br>7060 Mounting B Part No. Mounting Mounting Mounting Mounting Mounting Mounting<br>50 A B C D E F<br>——_——EeEee<br>4030 Mounting PS5R-VB05, 65 60 60 60 60 60<br>20 B, C, F -VB12, -VB24<br>10 PS5R-VC12 50 45 45 45 45 45<br>0-30 -20 -10 0 10 20 30 40 50 60 70 80 a PS5R-VC24 a 55 55 50 45 45 45<br>Operating Temperature (˚C) PS5R-VD24 55 40 40 40 45 35<br>poa PS5R-VE24 50 40 40 40 45 40<br>a PS5R-VF24 55 40 45 40 45 35<br>pT PS5R-VG24 50 35 30 30 45 30<br>Output Current (%) Output Current (%) Output Current (%)<br>Output Current (%) Output Current (%) Output Current (%)<br>Output Current (%)<br>**----- End of picture text -----**<br> ## PS5R-VD24 ## PS5R-VG24 APEM Switches & Pilot Lights Control Boxes Emergency Stop Switches Enabling Switches Safety Products Explosion Proof Terminal Blocks Relays & Sockets Circuit Protectors Power Supplies LED Illumination Controllers Operator Interfaces Sensors AUTO-ID Mounting Style **==> picture [300 x 46] intentionally omitted <==** **----- Start of picture text -----**<br> Up<br>Mounting A Mounting B Mounting C Mounting D Mounting E Mounting F<br>(Vertical, standard) (Upright) (Left side up) (Right side up) (Upside down) (Downward)<br>**----- End of picture text -----**<br> Output Current vs. Input Voltage (derating curves) PS5R-VG24 **==> picture [132 x 95] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>90<br>80<br>70<br>60<br>50<br>40<br>30<br>20<br>10<br>0<br>(ACV) 85 100 264<br>(DCV) 100 140 Input Voltage (V) 370<br>Output Current (%)<br>**----- End of picture text -----**<br> Download catalogs and CAD from http://asia.idec.com/downloads J-008 PS5R-V Switching Power Supplies ## Overcurrent Protection Characteristics PS5R-VB/VC/VD/VF PS5R-VE24 ## PS5R-VG24 **==> picture [544 x 307] intentionally omitted <==** **----- Start of picture text -----**<br> 100 100 100<br>95 95<br>APEM<br>Switches &<br>Pilot Lights<br>Intermittent Operation Intermittent Operation<br>Control Boxes<br>StoEmergency p Switches -30 00 Output Current (%) 100 105 and over 00 Output Current (%) 100 101 and over 00 Output Current (%) 100 105 and over<br>Enabling<br>Switches<br>Safety Products<br>Explosion Proof Parts Description<br>Terminal Blocks PS5R-VB/VC PS5R-VD/VE/VF PS5R-VG<br>Relays & Sockets<br>Circuit<br>Protectors<br>Power Supplies<br>LED Illumination<br>Controllers<br>Operator<br>Interfaces<br>Sensors<br>AUTO-ID<br>Output Voltage (%) Intermittent Operation Output Voltage (%) Output Voltage (%)<br>**----- End of picture text -----**<br> |PS5R-V<br>PS6R|Marki|ng<br>Name|Description<br>age range: 85 to 264V AC/100 to 370V DC<br>sure to connect this terminal to a proper ground.<br>Positive output terminal<br>Negative output terminal<br>ning clockwise increases the output voltage.<br>ningcounterclockwise decreases the output voltage.<br>hts when the output voltage is on.| |---|---|---|---| ||L, N|AC Input Terminal<br>Volt|| |||Ground Terminal<br>Be|| ||+V, –V|<br>DC Output Terminals<br>+V:<br>–V:|| ||VR.AD|J<br>Output Voltage Adjustment<br>Tur<br>Tur|| ||DC ON|<br>Operation Indicator (green)<br>Lig|| For more information, visit http://asia.idec.com J-009 PS5R-V Switching Power Supplies ## Dimensions ## PS5R-VB/VC **==> picture [305 x 674] intentionally omitted <==** **----- Start of picture text -----**<br> 5-M3.5<br>Screw Terminal 95<br>9.5 3.8<br>22.5<br> PS5R-VD/VE 5-M3.5<br>10 10 Screw Terminal<br>108<br>20 3.8<br>36<br> PS5R-VF<br>5-M3.5<br>11.5 11.5 Screw Terminal<br>121<br>23<br>3.8<br>46<br>5-M3.5<br>PS5R-VG Screw Terminal<br>9.5 9.5 125 5.5<br>9.5 9.5 9.5 9.5 3.8<br>60<br>8.2<br>12.2 27.3<br>90 35.3<br>61.6<br>4.4<br>8<br>24.9<br>9<br>7 95 35.3<br>4.5<br>85.<br>44.9<br>5<br>98 11<br>35.3<br>4.5<br>9.3<br>44.9<br>106.5 35.3 125<br>4.5<br>**----- End of picture text -----**<br> All dimensions in mm. Tolerance: ±1mm APEM Switches & Pilot Lights Control Boxes Emergency Stop Switches Enabling Switches Safety Products Explosion Proof Terminal Blocks Relays & Sockets Circuit Protectors Power Supplies LED Illumination Controllers Operator Interfaces Sensors AUTO-ID PS5R-V PS6R Download catalogs and CAD from http://asia.idec.com/downloads J-010 PS5R-V Switching Power Supplies ## Dimensions ## Panel Mounting Bracket **==> picture [527 x 694] intentionally omitted <==** **----- Start of picture text -----**<br> When installed on switching power supply<br>PS9Z-5R1B 2-M4 or ø2-4.5 holes<br>APEM<br>Switches &<br>Pilot Lights<br>Mounting hole layout<br>Control Boxes when installing ona panel directly 96.7<br>Emergency 12 12 Front View Side View<br>Stop Switches 24.7<br>Enabling PS9Z-5R2B Side-mount 2-M4 or ø2-4.5 holes 28.8 5.5<br>Switches<br>Safety Products<br>Explosion Proof<br>Mounting hole layout<br>Terminal Blocks when installing on<br>a panel directly<br>Relays & Sockets 44<br>62.9 Side View Front View<br>Circuit<br>Protectors<br>109.8<br>PS9Z-5R1C 2-M4 or ø2-4.5 holes<br>Power Supplies<br>LED Illumination<br>Controllers<br>Operator<br>Interfaces Mounting hole layout<br>when installing on<br>Sensors 26 26 a panel directly<br>38 Front View Side View<br>AUTO-ID<br>PS9Z-5R1E 2-M4 or ø2-4.5 holes 122.8<br>PS5R-V<br>PS6R<br>Mounting hole layout<br>when installing on<br>36 36 a panel directly<br>48 Front View Side View<br>PS9Z-6R1F 10.5 10.5 130.6<br>28 4-M4 or ø4-4.5 holes<br>Mounting hole layout<br>when installing on<br>a panel directly<br>28 28<br>39<br>Front View Side View<br>PS9Z-6R2F Side-mount<br>56 4-M4 or ø4-4.5 holes 62.3 29.5 31<br>All dimensions in mm.<br>Mounting hole Tolerance: ±1mm<br>layout for side<br>mounting<br>56 56<br>70<br>Mounting Screws<br>Side View Back View (4 M3×6 countersunk screws)<br>13.6<br>120 112 112<br>16.4<br>10.0<br>110 102.0 102<br>10.0<br>0.2<br>1<br>115 105 105<br>9.9<br>10.2<br>135 125 125<br>9.9<br>10<br>145 135 135<br>145<br>11.8<br>638.<br>148.6 138.6 1<br>11.8<br>**----- End of picture text -----**<br> For more information, visit http://asia.idec.com J-011 PS5R-V Switching Power Supplies Switches & Pilot Lights Control Boxes Emergency Stop Switches Enabling Switches Safety Products Circuit Protectors Power Supplies ## Safety Precautions Mount the PS5R-V in an enclosure. Do not use the PS5R-V alone as an Electric Facilities for General Use. Use the PS5R-V for electric facilities for business use only. - Do not use switching power supplies with electric equipment whose malfunction or inadvertent operation may damage the human body or life directly. - Make sure that the input voltage and output current do not exceed the ratings. If the input voltage and output current exceed the ratings, electric shock, fire, or malfunction may occur. - Do not touch the terminals of the switching power supply while input voltage is applied, otherwise electric shock may occur. - Provide the final product with protection against malfunction or damage that may be caused by malfunction of the switching power supply. ## Operating Instructions ## Notes for installation - Do not close the top and bottom openings of the PS5R-V to allow for heat radiation by convection. - Maintain a minimum of 10 mm clearance around the PS5R-V, except for the top and bottom openings. - When mounting multiple PS5R-V switching power supplies side by side, maintain a minimum of 10 mm clearance. Observe the derating curves in consideration of the ambient temperature. **==> picture [95 x 88] intentionally omitted <==** 10mm minimum - When the derating voltage may exceed the recommended value, provide forced air-cooling. - Make sure to wire the ground terminal correctly. - For wiring, use wires of heat resistance of 60oC or higher (PS5R-VB: 80oC or higher). Use copper wire of the following sizes, according to the rated current. - Operating temperatures should not exceed the ratings. Be sure to note the derating characteristics. If the operating temperature exceeds the ratings, electric shock, fire, or malfunction may occur. - Blown fuses indicate that the internal circuits are damaged. Contact IDEC for repair. Do not just replace the fuse and reoperate, otherwise electric shock, fire, or malfunction may occur. - Do not use the switching power supplies to charge rechargeable batteries. - Do not overload or short-circuit the switching power supply for a long period of time, otherwise the internal elements may be damaged. - Do not disassemble, repair, or modify the power supplies, otherwise the high voltage internal part may cause electric shock, fire, or malfunction. - The fuse inside the PS5R-V switching power supply is for AC input. Use a DC fuse for DC input. ## Mounting on DIN Rails 1. Use a 35mm-wide DIN rail. 2. Fasten the DIN rail to a mounting plate using screws. 3. Place the PS5R-V on the DIN rail as shown with input terminal side up ( ), and press the PS5R-V towards the DIN rail ( ). Make sure that the PS5R-V is installed firmly. 4. Use BNL6 mounting clips for fastening the PS5R-V on the DIN rail. Use of BNL8 mounting clips is recommended when excessive vibration or shock is anticipated. Do not use the PS5R-V when it is subject to vibration constantly. ## Removal - Insert a flat screwdriver into the slot in the clamp, and pull out the clamp until it clicks ( ). The lock mechanism is released and the PS5R-V can be removed ( ). When mounting the PS5R-V again, push in the latch first. **==> picture [170 x 85] intentionally omitted <==** **----- Start of picture text -----**<br> Mounting Removal<br>Clamp<br>**----- End of picture text -----**<br> APEM Explosion Proof Terminal Blocks Relays & Sockets LED Illumination Controllers Operator Interfaces Sensors AUTO-ID PS5R-V PS6R **==> picture [241 x 41] intentionally omitted <==** **----- Start of picture text -----**<br> Terminal Wire Size (allowable current) Wire Type<br>Input AWG18 to 14<br>Copper<br>AWG18 to 14<br>Output Solid/Stranded<br>(AWG18: 7A, AWG16: 10A, AWG14: 15A)<br>**----- End of picture text -----**<br> Cross-sectional area AWG18: 0.82mm[2] , AWG16: 1.31mm[2] , AWG14: 2.0mm[2] Note: Wires of the above size must be used to comply with UL508, CSA C22.2 No. 107.1. ## Applicable crimp terminal (reference) ø3.6 min. 7.0 max. 4.1 max. 5.6 min. (PS5R-VG: 6.3 min) - Recommended tightening torque of the input and output terminals is 1.0 to 1.3 N·m (0.8 N·m for UL). Download catalogs and CAD from http://asia.idec.com/downloads J-012 PS5R-V Switching Power Supplies APEM Switches & Pilot Lights Control Boxes Emergency Stop Switches Enabling Switches Safety Products Explosion Proof Terminal Blocks Circuit Protectors Power Supplies LED Illumination Controllers Operator Interfaces Sensors AUTO-ID PS5R-V PS6R ## Operating Instructions Relays & Sockets ## Installing the Panel Mounting Bracket ## <Installing PS9Z-5R1� Panel Mounting Bracket> ## Panel Mounting Bracket (PS9Z-5R1�) **==> picture [223 x 172] intentionally omitted <==** **----- Start of picture text -----**<br> Tab � Push in the latch to LOCK<br>� position.<br>Slot<br>LOCK<br>Power<br>Supply<br>UNLOCK<br>�<br>Latch<br>� Install the tab on the panel<br>mounting bracket into the slot on<br>�<br>the power supply.<br>� Install the brackets as shown on<br>the left.<br>**----- End of picture text -----**<br> **==> picture [8 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> �<br>**----- End of picture text -----**<br> - Ensure that the panel mounting bracket is locked by the latch. - LOCK ## <Installing PS9Z-5R2B Panel Mounting Bracket> Panel Mounting Bracket (PS9Z-5R2B) - Pull out the latch to UNLOCK position. LOCK **==> picture [228 x 84] intentionally omitted <==** **----- Start of picture text -----**<br> LOCK<br>Tab<br>� UNLOCK<br>�<br>� Insert the tab on the panel<br>Latch Power mounting bracket into the slot on<br>Supply the power supply.<br>**----- End of picture text -----**<br> **==> picture [77 x 43] intentionally omitted <==** - - Push in the latch to LOCK position. - � Ensure that the panel mounting bracket is locked by the latch. - LOCK ## Adjustment of Output Voltage The output voltage can be adjusted within ±10% of the rated output voltage (PS5R-VE: ±5%) by using the VR.ADJ control on the front. Turning the VR.ADJ clockwise increases the output voltage. Turning the VR.ADJ counterclockwise decreases the output voltage. ## Overcurrent Protection The output voltage drops automatically when an overcurrent flows due to an overload or short circuit. Normal voltage is auto matically restored when the load returns to normal conditions. ## Insulation/Dielectric Test When performing an insulation/dielectric test, short-circuit the input (between L and N) and output (between +V and –V). Do not apply or interrupt the voltage quickly, otherwise surge volt ages may be generated and the PS5R-V may be damaged. ## Notes for Operation • Output interruption may indicate blown fuses. Contact IDEC. The PS5R-V switching power supply contains an internal fuse for AC input. When using with DC input, install an exter nal fuse for DC input. To avoid blown fuses, select a fuse in consideration of the rated current of the internal fuse. ## Rated Current of Internal Fuses |PS5R-VB/VC|2A| |---|---| |PS5R-VD/VE/VF|4A| |PS5R-VG|6.3A| - Avoid overload and short-circuit for a long period of time, oth erwise the internal elements may be damaged. - DC input operation is not subject to safety standards. ## Rust and Scratches on Metal parts Hot-dip galvanized steel and bonderized steel are used for the PS5R-V. Rust on the edge and scratches on the surfaces may be developed depending on the storage condition, but the performance of the PS5R-V is not affected. ## Noise Small acoustic noise inside the PS5R-V may be heard depending on the input voltage and load, but the performance of the PS5R-V is not affected. ## Installing PS9Z-6R2F Side-mount Panel Mounting Bracket Install the bracket on the switching power supply using four M3 × 6 countersunk screws supplied with the bracket. For more information, visit http://asia.idec.com J-013 PS5R-V Switching Power Supplies Switches & Pilot Lights Control Boxes Emergency Stop Switches Enabling Switches Safety Products ## Operating Instructions ## Series Operation The following series operation is allowed. In (b) series operation, connect Schottky barrier diodes. Choose (a) series operation when using the PS5R-V as positive and negative output power supply. Insert a Shottky barrier diode for loads such as operational amplifier where outputs of two power supplies may be connected in series (Load 3). Select a Schottky diode in consideration of the rated current. **==> picture [197 x 61] intentionally omitted <==** **----- Start of picture text -----**<br> L L +V L L +V<br>N N –V Load 1 N N –V<br>Load 3 Load<br>L +V Load 2 L +V<br>N –V N –V<br>(a) (b)<br>**----- End of picture text -----**<br> ## Parallel Operation Parallel operation is not possible to increase the output capacity, because the internal elements and load may be damaged. ## Backup Operation Backup operation is a connection method of two switching power supplies in parallel for emergency. Normally one switching power supply has a sufficient output. If one switching power supply fails, another one operates to continue the output. Make sure that the sum of power consumption by load and diode is not greater than the rated wattage (rated voltage × rated current) of one switching power supply. **==> picture [98 x 45] intentionally omitted <==** **----- Start of picture text -----**<br> D<br>+<br>AC IN OUT Load<br>–<br>D<br>+<br>IN OUT<br>–<br>**----- End of picture text -----**<br> ## Select a diode in consideration of: Diode's current must be more than double the PS5R-V's output current. Take heat dissipation into consideration. APEM Explosion Proof Terminal Blocks Relays & Sockets ## Warranty ## Warranty IDEC warranties the PS5R-V switching power supplies for a period of five years from the date of shipment. ## Scope IDEC agrees to repair or replace the PS5R-V switching power supply if the product has been operated under the following conditions. The maximum value of output capacity is within the range shown in “Operating Temperature vs. Output Current" on J-008. 1. Average operating temperature (ambient temperature of switching power supply) is 40°C maximum. IDEC shall not be liable for other damages including consequential, contingent or incidental damages. Warranty does not apply if the PS5R-V switching power supply was subject to: 1. Inappropriate handling, or operation beyond the specifications. 2. Modification or repair by other than IDEC. 3. Failure caused by other than the PS5R-V switching power supply. 4. Failure caused by natural disasters. Circuit Protectors Power Supplies LED Illumination Controllers Operator Interfaces Sensors AUTO-ID PS5R-V 2. The load is 80% maximum. 3. Input voltage is the rated input voltage. PS6R 4. Standard mounting style Download catalogs and CAD from http://asia.idec.com/downloads J-014 ## Ordering Terms and Conditions ## Thank you for using IDEC Products. By purchasing products listed in our catalogs, datasheets, and the like (hereinafter referred to as “Catalogs”) you agree to be bound by these terms and conditions. Please read and agree to the terms and conditions before placing your order. ## 1. Notes on contents of Catalogs - (1) Rated values, performance values, and specification values of IDEC products listed in this Catalog are values acquired under respective conditions in independent testing, and do not guarantee values gained in combined conditions. - Also, durability varies depending on the usage environment and usage conditions. - (2) Reference data and reference values listed in Catalogs are for reference purposes only, and do not guarantee that the product will always operate appropriately in that range. - (3) The specifications / appearance and accessories of IDEC products listed in Catalogs are subject to change or termination of sales without notice, for improvement or other reasons. - (4) The content of Catalogs is subject to change without notice. ## 2. Note on applications - (1) If using IDEC products in combination with other products, confirm the applicable laws / regulations and standards. Also, confirm that IDEC products are compatible with your systems, machines, devices, and the like by using under the actual conditions. IDEC shall bear no liability whatsoever regarding the compatibility with IDEC products. - (2) The usage examples and application examples listed in Catalogs are for reference purposes only. Therefore, when introducing a product, confirm the performance and safety of the instruments, devices, and the like before use. Furthermore, regarding these examples, IDEC does not grant license to use IDEC products to you, and IDEC offers no warranties regarding the ownership of intellectual property rights or non-infringement upon the intellectual property rights of third parties. - (3) When using IDEC products, be cautious when implementing the following. i. Use of IDEC products with sufficient allowance for rating and performance - ii. Safety design, including redundant design and malfunction prevention design that prevents other danger and damage even in the event that an IDEC product fails - iii. Wiring and installation that ensures the IDEC product used in your system, machine, device, or the like can perform and function according to its specifications - (4) Continuing to use an IDEC product even after the performance has deteriorated can result in abnormal heat, smoke, fires, and the like due to insulation deterioration or the like. Perform periodic maintenance for IDEC products and the systems, machines, devices, and the like in which they are used. - (5) IDEC products are developed and manufactured as general-purpose products for general industrial products. They are not intended for use in the following applications, and in the event that you use an IDEC product for these applications, unless otherwise agreed upon between you and IDEC, IDEC shall provide no guarantees whatsoever regarding IDEC products. - i. Use in applications that require a high degree of safety, including nuclear power control equipment, transportation equipment (railroads / airplanes / ships / vehicles / vehicle instruments, etc.), equipment for use in outer space, elevating equipment, medical instruments, safety devices, or any other equipment, instruments, or the like that could endanger life or human health - ii. Use in applications that require a high degree of reliability, such as provision systems for gas / waterworks / electricity, etc., systems that operate continuously for 24 hours, and settlement systems ## 3. Inspections We ask that you implement inspections for IDEC products you purchase without delay, as well as thoroughly keep in mind management/maintenance regarding handling of the product before and during the inspection. ## 4. Warranty - (1) Warranty period The warranty period for IDEC products shall be one (1) year after purchase or delivery to the specified location. However, this shall not apply in cases where there is a different specification in the Catalogs or there is another agreement in place between you and IDEC. - (2) Warranty scope Should a failure occur in an IDEC product during the above warranty period for reasons attributable to IDEC, then IDEC shall replace or repair that product, free of charge, at the purchase location / delivery location of the product, or an IDEC service base. However, failures caused by the following reasons shall be deemed outside the scope of this warranty. - i. The product was handled or used deviating from the conditions / environment listed in the Catalogs ii. The failure was caused by reasons other than an IDEC product - iii. Modification or repair was performed by a party other than IDEC - iv. The failure was caused by a software program of a party other than IDEC - v. The product was used outside of its original purpose - vi. Replacement of maintenance parts, installation of accessories, or the like was not performed properly in accordance with the user’s manual and Catalogs vii. The failure could not have been predicted with the scientific and technical standards at the time when the product was shipped from IDEC viii. The failure was due to other causes not attributable to IDEC (including cases of force majeure such as natural disasters and other disasters) Furthermore, the warranty described here refers to a warranty on the IDEC product as a unit, and damages induced by the failure of an IDEC product are excluded from this warranty. ## 5. Limitation of liability The warranty listed in this Agreement is the full and complete warranty for IDEC products, and IDEC shall bear no liability whatsoever regarding special damages, indirect damages, incidental damages, or passive damages that occurred due to an IDEC product. ## 6. Service scope The prices of IDEC products do not include the cost of services, such as dispatching technicians. Therefore, separate fees are required in the following cases. - (1) Instructions for installation / adjustment and accompaniment at test operation (including creating application software and testing operation, etc.) - (2) Maintenance inspections, adjustments, and repairs - (3) Technical instructions and technical training - (4) Product tests or inspections specified by you The above content assumes transactions and usage within your region. Please consult with an IDEC sales representative regarding transactions and usage outside of your region. Also, IDEC provides no guarantees whatsoever regarding IDEC products sold outside your region. - iii. Use in applications where the product may be handled or used deviating from the specifications or conditions / environment listed in the Catalogs, such as equipment used outdoors or applications in environments subject to chemical pollution or electromagnetic interference If you would like to use IDEC products in the above applications, be sure to consult with an IDEC sales representative. ## ## **www.idec.com** 6-64, Nishi-Miyahara-2-Chome, Yodogawa-ku, Osaka 532-0004, Japan **USA** IDEC Corporation Tel: +1-408-747-0550 opencontact@idec.com **Germany** APEM GmbH Tel: +49-40-25 30 54-0 service@eu.idec.com **Singapore** IDEC Izumi Asia Pte. Ltd. Tel: +65-6746-1155 info@sg.idec.com **Thailand** IDEC Asia (Thailand) Co., Ltd Tel: +66-2-392-9765 sales@th.idec.com **Australia** IDEC Australia Pty. Ltd. Tel: +61-3-8523-5900 sales@au.idec.com **India** IDEC Controls India Private Limited Tel: +91-80679-35328 info_india@idec.com **Taiwan** IDEC Taiwan Corporation Tel: +886-2-2577-6938 service@tw.idec.com **Hong Kong** IDEC Izumi (H.K.) Co., Ltd. Tel: +852-2803-8989 info@hk.idec.com **China/Shanghai** IDEC (Shanghai) Corporation Tel: +86-21-6135-1515 idec@cn.idec.com **China/Shenzhen** IDEC (Shenzhen) Corporation Tel: +86-755-8356-2977 idec@cn.idec.com **China/Beijing** IDEC (Beijing) Corporation Tel: +86-10-6581-6131 idec@cn.idec.com **Japan** IDEC Corporation Tel: +81-6-6398-2527 marketing@idec.co.jp **==> picture [96 x 34] intentionally omitted <==**
Updated at June 4, 2026
Founded in 1945, IDEC is a globally recognized leader in industrial automation, machine safety, and control products. Renowned for pioneering innovations in Human-Machine Interface (HMI) systems, the company is dedicated to creating a safe and efficient harmony between advanced workplace technology and human operators. At the core of IDEC’s extensive portfolio is a comprehensive selection of high-performance relays designed for demanding industrial environments. This includes a broad range of electromechanical power relays, solid-state relays, contactors, and critical safety relays, supported by a wide array of specialized relay accessories to ensure reliable and efficient switching. Beyond switching components, IDEC provides complete solutions for modern control panels and automated systems. Their robust engineering extends to advanced panel displays and instrumentation, precision light sensors, and dependable AC/DC power converters. With additional offerings in industrial switches, visual signaling units, and DIN rail terminal blocks, IDEC equips engineers with the high-quality components required to build secure, next-generation automation infrastructure.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →