Image not available
Illustrative purposes only
PS-05-12
AC/DC Open Frame Power Supply (PSU), ITE, 1 Output, 5.4 W, 85V AC to 264V AC, Fixed
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC Open Frame Power Supplies
- SVHC: No SVHC (27-Jun-2024)
- Product Range: PS-05 Series
- No. of Outputs: 1 Output
- Input Voltage VAC: 85V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 450mA
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 12VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
- Power Rating (Forced Cooling): -
- Power Rating (Convection Cooling): 5.4W
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 8.0 € |
| Current stock | 10+ |
| Lead time | 30 days |
**PS - 05 series** ## MEAN WELL 5W Single Output Switching Power Supply **- series** ~~a~~ ## ■ ## **SPECIFICATION** |**PS-05-5**<br>**PS-05-12**<br>**PS-05-15**<br>**PS-05-24**<br>**PS-05-48**<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**HOLD UP TIME(Typ.)**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**EFFICIENCY(Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**SAFETY STANDARDS**<br>**WORKING HUMIDITY**<br>**WORKING TEMP.**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**AC CURRENT (Typ.)**<br>5V<br>12V<br>15V<br>24V<br>48V<br>1A<br>0.45A<br>0.35A<br>0.22A<br>0.11A<br>0 ~ 1.2A<br>0 ~ 0.5A<br>0 ~ 0.4A<br>0 ~ 0.25A<br>0 ~ 0.125A<br>5W<br>5.4W<br>5.25W<br>5.28W<br>5.28W<br>100mVp-p<br>120mVp-p<br>120mVp-p<br>200mVp-p<br>200mVp-p<br>±2.0%<br>±2.0%<br>±2.0%<br>±2.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>100ms at full load<br>85 ~ 264VAC 120 ~ 370VDC<br>47 ~ 63Hz<br>70%<br>75%<br>13.8 ~ 16.2V<br>17.2 ~ 20.2V<br>27.6 ~ 32.4V<br>55.2 ~ 64.8V<br>75%<br>76%<br>76%<br>0.15A/115VAC 0.07A/230VAC<br>COLD START 30A/230VAC<br><0.5mA / 240VAC<br>Above 105%rated output power<br>5.75 ~ 6.75V<br>Protection type : Hiccup mode, recovery automatically after fault condition is removed<br>Hiccup mode, recovery automatically after fault condition is removed<br>-10 ~ +60<br>(Refer to "Derating Curve")<br>℃<br>20 ~ 90% RH non-condensing<br>-20 ~ +85<br>, 10 ~ 95% RH<br>℃<br>±<br>℃<br>℃<br>0.05%/<br>(0 ~ 50<br>)<br>10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>75*40*20mm (L*W*H)<br>0.05Kg; 120pcs/6.25Kg/0.56CUFT<br>**OVER TEMPERATURE**<br>**HARMONIC CURRENT**<br>**EMS IMMUNITY**<br>EAC TP TC 004approved, IEC62368-1 CB approved by TUV<br>Compliance to EN55032 (CISPR32) Class B, EAC TP TC 020<br>Compliance to EN61000-3-2,-3<br>Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A, EAC TP TC 020<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3KVAC<br>I/P-O/P:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>**EMI CONDUCTION & RADIATION**<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**(Note 4)**<br>**PROTECTION**<br>℃<br>(as available on http://www.meanwell.com)<br>℃<br>℃<br>※<br>:<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCE Note.3**<br>**SETUP, RISE TIME**<br>1000ms, 20ms<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25 _ of ambient temperature.<br>2. Ripple & noise are measured at20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance: includes set up tolerance, line regulation and load regulation.<br>4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>5. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft)<br>Product Liability Disclaimer<br>For detailed information, please refer to|**PS-05-5**<br>**PS-05-12**<br>**PS-05-15**<br>**PS-05-24**<br>**PS-05-48**<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**HOLD UP TIME(Typ.)**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**EFFICIENCY(Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**SAFETY STANDARDS**<br>**WORKING HUMIDITY**<br>**WORKING TEMP.**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**AC CURRENT (Typ.)**<br>5V<br>12V<br>15V<br>24V<br>48V<br>1A<br>0.45A<br>0.35A<br>0.22A<br>0.11A<br>0 ~ 1.2A<br>0 ~ 0.5A<br>0 ~ 0.4A<br>0 ~ 0.25A<br>0 ~ 0.125A<br>5W<br>5.4W<br>5.25W<br>5.28W<br>5.28W<br>100mVp-p<br>120mVp-p<br>120mVp-p<br>200mVp-p<br>200mVp-p<br>±2.0%<br>±2.0%<br>±2.0%<br>±2.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>100ms at full load<br>85 ~ 264VAC 120 ~ 370VDC<br>47 ~ 63Hz<br>70%<br>75%<br>13.8 ~ 16.2V<br>17.2 ~ 20.2V<br>27.6 ~ 32.4V<br>55.2 ~ 64.8V<br>75%<br>76%<br>76%<br>0.15A/115VAC 0.07A/230VAC<br>COLD START 30A/230VAC<br><0.5mA / 240VAC<br>Above 105%rated output power<br>5.75 ~ 6.75V<br>Protection type : Hiccup mode, recovery automatically after fault condition is removed<br>Hiccup mode, recovery automatically after fault condition is removed<br>-10 ~ +60<br>(Refer to "Derating Curve")<br>℃<br>20 ~ 90% RH non-condensing<br>-20 ~ +85<br>, 10 ~ 95% RH<br>℃<br>±<br>℃<br>℃<br>0.05%/<br>(0 ~ 50<br>)<br>10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>75*40*20mm (L*W*H)<br>0.05Kg; 120pcs/6.25Kg/0.56CUFT<br>**OVER TEMPERATURE**<br>**HARMONIC CURRENT**<br>**EMS IMMUNITY**<br>EAC TP TC 004approved, IEC62368-1 CB approved by TUV<br>Compliance to EN55032 (CISPR32) Class B, EAC TP TC 020<br>Compliance to EN61000-3-2,-3<br>Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A, EAC TP TC 020<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3KVAC<br>I/P-O/P:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>**EMI CONDUCTION & RADIATION**<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**(Note 4)**<br>**PROTECTION**<br>℃<br>(as available on http://www.meanwell.com)<br>℃<br>℃<br>※<br>:<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCE Note.3**<br>**SETUP, RISE TIME**<br>1000ms, 20ms<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25 _ of ambient temperature.<br>2. Ripple & noise are measured at20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance: includes set up tolerance, line regulation and load regulation.<br>4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>5. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft)<br>Product Liability Disclaimer<br>For detailed information, please refer to|**PS-05-5**|**PS-05-12**|**PS-05-15**|**PS-05-24**<br>**PS-05-48**|**PS-05-48**| |---|---|---|---|---|---|---| ||**DC VOLTAGE**|5V|12V|15V|24V<br>48V|48V| ||**RATED CURRENT**|1A|0.45A|0.35A|0.22A<br>0.11A|0.11A| ||**CURRENT RANGE**|0 ~ 1.2A|0 ~ 0.5A|0 ~ 0.4A|0 ~ 0.25A<br>0 ~ 0.125A|0 ~ 0.125A| ||**RATED POWER**|5W|5.4W|5.25W|5.28W<br>5.28W|5.28W| ||**RIPPLE & NOISE (max.) Note.2**|100mVp-p|120mVp-p|120mVp-p|200mVp-p<br>200mVp-p|200mVp-p| ||**VOLTAGE TOLERANCE Note.3**|±2.0%|±2.0%|±2.0%|±2.0%<br>±|±1.0%| ||**LINE REGULATION**|±1.0%|±1.0%|±1.0%|±0.5%<br>±|±0.5%| ||**LOAD REGULATION**|±1.0%|±1.0%|±1.0%|±0.5%<br>±|±0.5%| ||**SETUP, RISE TIME**|1000ms, 20ms||||| ||**HOLD UP TIME(Typ.)**|100ms at full load||||| ||**VOLTAGE RANGE**|85 ~ 264VAC 120 ~ 370VDC||||| ||**FREQUENCY RANGE**|47 ~ 63Hz||||| ||**EFFICIENCY(Typ.)**|70%|75%|75%|76%|76%| ||**AC CURRENT (Typ.)**|0.15A/115VAC 0.07A/230VAC||||| ||**INRUSH CURRENT (Typ.)**|COLD START 30A/230VAC||||| ||**LEAKAGE CURRENT**|<0.5mA / 240VAC||||| ||**OVERLOAD**|Above 105%rated output power<br>Protection type : Hiccup mode, recovery automatically after fault condition is removed||||| ||**OVER VOLTAGE**|5.75 ~ 6.75V|13.8 ~ 16.2V|17.2 ~ 20.2V|27.6 ~ 32.4V|55.2 ~ 64.8V| ||**OVER TEMPERATURE**|Hiccup mode, recovery automatically after fault condition is removed||||| ||**WORKING TEMP.**|-10 ~ +60<br>(Refer to "Derating Curve")<br>℃||||| ||**WORKING HUMIDITY**|20 ~ 90% RH non-condensing||||| ||**STORAGE TEMP., HUMIDITY**|-20 ~ +85<br>, 10 ~ 95% RH<br>℃||||| ||**TEMP. COEFFICIENT**|±<br>℃<br>℃<br>0.05%/<br>(0 ~ 50<br>)||||| ||**VIBRATION**|10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes||||| ||**SAFETY STANDARDS**|EAC TP TC 004approved, IEC62368-1 CB approved by TUV||||| ||**WITHSTAND VOLTAGE**|I/P-O/P:3KVAC||||| ||**ISOLATION RESISTANCE**|I/P-O/P:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃||||| ||**EMI CONDUCTION & RADIATION**|Compliance to EN55032 (CISPR32) Class B, EAC TP TC 020||||| ||**HARMONIC CURRENT**|Compliance to EN61000-3-2,-3||||| ||**EMS IMMUNITY**|Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A, EAC TP TC 020||||| ||**DIMENSION**|75*40*20mm (L*W*H)||||| ||**PACKING**<br>0.05Kg; 120pcs/6.25Kg/0.56CUFT<br>℃<br>(as available on http://www.meanwell.com)<br>℃<br>℃<br>※<br>:<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25 _ of ambient temperature.<br>2. Ripple & noise are measured at20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance: includes set up tolerance, line regulation and load regulation.<br>4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>5. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft)<br>Product Liability Disclaimer<br>For detailed information, please refer to|||||| _File Name:PS-05-SPEC 2020-10-20_ **PS - 05 series** ## 5W Single Output Switching Power Supply **==> picture [482 x 637] intentionally omitted <==** **----- Start of picture text -----**<br> Mechanical Specification Unit:mm<br>75<br>67<br>To chassis Grounding<br>1<br>2 CN1<br>3 1<br>CN2 2<br>AC Input Connector (CN2) : Molex 5285-03 or equivalent DC Output Connector (CN1) : Molex 5273-02 or equivalent<br>Pin No. Assignment Mating Housing Terminal Pin No. Assignment Mating Housing Terminal<br>1 FG 1 +V Molex 5195 Molex 5194<br>Molex 5058 Molex 2478<br>2 AC/N or equivalent or equivalent 2 -V or equivalent or equivalent<br>3 AC/L : Grounding Required<br>CN2:Pin 1 is safety ground<br>Block Diagram fosc : 67KHz<br>RECTIFIERS POWER RECTIFIERS<br>EMI +V<br>I/P & SWITCH- &<br>FILTER FILTER ING FILTER -V<br>PWM<br>CONTROL<br>FG DETECTION<br>CIRCUIT<br>Derating Curve Static Characteristics<br>100<br>100<br>90<br>80<br>80<br>60 70<br>60<br>40<br>50<br>20<br>40<br>-10 0 10 20 30 40 50 60 (HORIZONTAL) 85 90 95 100 105 264<br>AMBIENT TEMPERATURE ( ℃ ) INPUT VOLTAGE (V) 60Hz<br>4-<br>3.5<br>LOAD (%) LOAD (%)<br>40 32<br>20<br>**----- End of picture text -----**<br> _File Name:PS-05-SPEC 2020-10-20_
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →