- Manufacturer: TE CONNECTIVITY - POTTER&BRUMFIELD
- Product type: Power Relays
- Contact Configuration:DPDT; Coil Voltage:480VAC; Contact Current:25A; Product Range:PRD Series; Relay Mounting:Panel Mount; Coil Type:-; Contact Voltage VAC:240V; Rela 17M1536
- Coil Type: -
- Coil Voltage: 480VAC
- Product Range: PRD Series
- Relay Mounting: Panel Mount
- Coil Resistance: 4.5kohm
- Contact Current: 25A
- Relay Terminals: Screw
- Contact Material: Silver
- Contact Voltage VAC: 240V
- Contact Voltage VDC: 50V
- Contact Configuration: DPDT
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 68.46 € |
| Current stock | 10+ |
| Lead time | 30 days |
General Purpose Panel/Plug-in Relays **Potter & Brumfield** ## **PRD Series Power Relay** ## n **Contact ratings to 50A** > n **Magnetic blowouts available for switching DC loads** > n **Contact arrangement up to 2 form C (2CO)** > n **1 form C auxiliary switch available** > n **UL class B insulation** Typical applications Industrial controls, lighting. ## ~~**Approvals**~~ ## ~~**Contact ratings** (continued)~~ UL E22575; CSA LR15734; VDE Reg.Nr.C144 |UL E22575; CSA LR15734; VDE Reg.Nr.C144|UL E22575; CSA LR15734; VDE Reg.Nr.C144|UL E22575; CSA LR15734; VDE Reg.Nr.C144|UL E22575; CSA LR15734; VDE Reg.Nr.C144|Type|Load|Cycles| |---|---|---|---|---|---|---| |Models with all screw terminals are UL Listed. Others are UL Recognized.|Models with all screw terminals are UL Listed. Others are UL Recognized.|||**UL 5081)**||| |Technical data of approved types on request.||||Models with screws or quick connects for main terminals||| |~~**Contact Data**~~||||Code F, AgCdO, 1 pole<br>50A, 240VAC, general purpose2)||20x103| |Contact arrangement|Contact arrangement<br>1 and 2 form A (NO); 1 and 2 form C (CO);||1 and 2 form A (NO); 1 and 2 form C (CO);||30A, 277VAC, resistive|100x103| |||1 form X (NO-DM)|||1.5HP, 120VAC|100x103| |Rated voltage|||600VAC,125VDC||2HP, 250VAC|100x103| |Rated current|||50A||10A, 600VAC|100x103| |Contact material<br>Min. recommended contact load||Ag, AgCdO, W<br>1A, 12VDC or 12VAC||Code F, AgCdO, 2 pole<br>50A, 240VAC, general purpose2)||20x103| |Initial contact resistance|||75mΩ max.||30A, 240VAC|100x103| |Initial voltage drop|||75mV||20A, 277VAC|100x103| |Frequency of operation|||7200 ops/hr||1.5HP, 120VAC|100x103| |Operate/releases time max.|||40/20ms||2HP, 250VAC|100x103| |Bounce time max.|||10ms||10A, 600VAC|100x103| |||||2) In order to achieve 50A rating with contact code F, termination Code 0 or A is required.|2) In order to achieve 50A rating with contact code F, termination Code 0 or A is required.|2) In order to achieve 50A rating with contact code F, termination Code 0 or A is required.| |**Contact ratings**||||||| |Type|Load||Cycles|Code H, Ag with magnetic blowout, 1 or 2 pole||| |**UL 5081)**|||||20A, 125VDC|100x103| |Models with screws or quick connects for main terminals||Models with screws or quick connects for main terminals|||1/3HP, 125VDC|100x103| |Code Y, Ag, 1 pole||||Code J, AgCdO with magnetic blowout, 1 or 2 pole|Code J, AgCdO with magnetic blowout, 1 or 2 pole|| ||25A, 277VAC||100x103||20A, 125VDC|100x103| ||1HP, 120VAC||100x103||1/3HP, 125VDC|100x103| ||2HP, 250VAC||100x103|Code N, W stationary with AgCdO movable, 1 or 2 pole||| ||10A, 600VAC||100x103||25A, 250VAC|100x103| ||7A, 50VDC, resistive|7A, 50VDC, resistive|100x103||1HP, 125VAC|100x103| |Code Y, Ag, 2 pole|||||2HP, 250VAC|100x103| ||25A, 240VAC||100x103|**UL 5081)**||| ||20A, 277VAC||100x103|Models with box lugs for main terminals|Models with box lugs for main terminals|| ||1HP, 120VAC||100x103|Code P, Ag, 1 form X|Code P, Ag, 1 form X|| ||2HP, 250VAC||100x103||50A, 277VAC, general purpose|100x103| ||7A, 50VDC, resistive|7A, 50VDC, resistive|100x103||30A, 277VAC, ballast|6x103| ||10A, 600VAC||100x103||15A, 277VAC, tungsten|6x103| |Code G, AgCdO, 1 pole|||||102LRA, 17FLA, 240VAC|30x103| ||30A, 277VAC, resistive||100x103||120LRA, 20FLA, 120VAC|30x103| ||1.5HP, 120VAC||100x103||1.5HP, 120VAC|30x103| ||2HP, 250VAC||100x103||3HP, 240VAC|30x103| ||10A, 600VAC||100x103|**Factory ratings**||| |Code G, AgCdO, 2 pole||||Models with box lugs for main terminals|Models with box lugs for main terminals|| ||30A, 240VAC||100x103|Code R, Ag with magnetic blowout, 1 form X||| ||20A, 277VAC||100x103|60A, 28VDC, resistive|60A, 28VDC, resistive|100x103| ||1.5HP, 120VAC||100x103|30A, 125VDC|30A, 125VDC|100x103| ||2HP, 250VAC||100x103|||| ||10A, 600VAC||100x103|Mechanical endurance DC Coil, 1x106ops.; AC Coil 5x105ops.||| 1) Any PRD relay deviating electrically or physically from the standard models in the table is not UL or CSA listed. All horsepower ratings are for single phase motors.. |~~**Auxiliary Snap-Action Switch Contact Data**~~|~~**Action Switch Contact Data**~~| |---|---| |Contact arrangement|1 form C (CO)| |Rating|5A, 120VAC, 60Hz., 25°C| |Contact material|Ag| 1 Catalog and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Catalog product data, ‘Definitions’ section, application notes and all specifications are subject to change. Catalog and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions 06-2015, Rev. 0615 www.te.com © 2015 Tyco Electronics Corporation, a TE Connectivity Ltd. company. General Purpose Panel/Plug-in Relays **Potter & Brumfield** ## **PRD Series Power Relay** (Continued) |~~**Coil Data**~~|~~**Coil Data**~~||||||~~**Insulation Data**~~|| |---|---|---|---|---|---|---|---|---| |Coil voltage range|Coil voltage range|||6 to 110VDC|||Initial dielectric strength|| |||||6 to 480VAC|||between open contacts|2000Vrms| |Coil insulation system according UL|||Coil insulation system according UL|Class B|||between contact and coil|2000Vrms| |**Coil versions, DC coil**|||||||between adjacent contacts|2000V~~rms~~| |Coil|Rated|Operate|Release|Release<br>Coil|Rated coil||Initial insulation resistance|| |code|voltage|voltage|voltage|resistance|power||between insulated elements|100MΩ| ||VDC|VDC|VDC|Ω±10%|W|||| |6|6|4.5|0.6|18|2||~~**Other Data**~~|| |12|12|9|1.2|71|2||Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content|| |24|24|18|2.4|288|2||refer to the Product Compliance Support Center at|refer to the Product Compliance Support Center at| |48|48|36|4.8|1150|2||www.te.com/customersupport/rohssupportcenter|| |110|110|82.5|11|6050|2||Ambient temperature|| |All figures are given for coil without preenergization, at ambient temperature +23°C.|||||All figures are given for coil without preenergization, at ambient temperature +23°C.||AC coil: -55ºC to 45ºC|| |Other coil voltages on request.||Other coil voltages on request.|||||DC coil:-55°C to 80°C|| |**Coil versions, AC coil**<br>Coil<br>Rated<br>code<br>voltage<br>VAC<br>6<br>6||Operate<br>voltage<br>VAC<br>5.1|Release<br>voltage<br>VAC<br>0.6|Release<br>Coil<br>resistance<br>Ω±15%<br>0.86|Rated coil<br>power<br>VA<br>9.8||Category of environmental protection<br>IEC 61810<br>Terminal type<br>Screw, Quick connects, Box lugs<br>Weight<br>Packaging/unit|RT0-open relay<br>Screw, Quick connects, Box lugs<br>284g<br>tray/20 pcs., box/40pcs.| |12|12|10.2|1.2|3.2|9.8||~~**Accessories**~~|| |24|24|20.4|2.4|12|9.8|||| |120<br>240|120<br>240|102<br>204|12<br>24|290<br>1200|9.8<br>9.8||Product Code Description<br>35D013<br>Metal dust cover|| |480|480|408|48|4500|9.8|||| All figures are given for coil without preenergization, at ambient temperature +23°C. Other coil voltages on request. ## **Dimensions** **==> picture [521 x 286] intentionally omitted <==** **----- Start of picture text -----**<br> PRD/PRDA 1, 3, 5 and 7 PRD/PRDA 11 PRD-3_P and R<br>2 MTG. HOLES<br>.875 MAX.(22.23) 2.5 MAX.(63.3).81 (7.9).31 .875 MAX.(22.23) 3.375 MAX.(85.73) 1.687 (7.9).31 (7.9).31 .187 + .005 – .003DIA.<br>(20.6) (42.85) ( )4.75 + .13 – .08<br>4 2 6 4 2 6 2 6<br>2.51 MAX. 8 2.51 MAX. 2.50<br>hs) evita’<br>(63.75) (63.8) (63.5)<br>COIL (47.63)1.875 COIL 7 (47.63)1.875 (47.63)1.875 COIL CONNECTORBOX LUG<br>3 1 5 3 1 5 1 5<br>aii oy 2 MTG. HOLES r y .81<br>2 MTG. HOLES DIA. (20.6)<br>DIA. .187 + .005<br>8B | ns .187 + .005 a mc s&s Das – .003 et 2.5 MAX. t .59 MAX.<br> – .003 4.75 + .13 (64) (15.0)<br>4.75 + .13 ( ) – .08<br>( ) – .08<br>2.28 MAX.<br>(57.9)<br>2.50 MAX. ON PRD7 2.50 MAX. 2.28 MAX.<br> (63.5) (63.5) (57.9)<br>.375<br>(9.53)<br>2.23 3.00<br>3.375 (56.6) 4.250 MAX. (76.2) .375 .375<br>(85.73) (107.95) (9.53) (9.53)<br>2.5 MAX.(63.5) W/O AUX SWITCH 3.375 MAX.(85.73) W/O AUX SWITCH<br>**----- End of picture text -----**<br> Catalog and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Catalog and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions 2 Catalog product data, ‘Definitions’ section, application notes and all specifications are subject to change. 06-2015, Rev. 0615 www.te.com © 2015 Tyco Electronics Corporation, a TE Connectivity Ltd. company. General Purpose Panel/Plug-in Relays **Potter & Brumfield** ## **PRD Series Power Relay** (Continued) ## **Terminal assignment for models with magnetic blowout** **==> picture [516 x 389] intentionally omitted <==** **----- Start of picture text -----**<br> PRD3 with blowout PRD7 with blowout PRD 11 with blowout<br>THIS SIDE OF MAGNET THIS SIDE OF MAGNET THIS SIDE OF MAGNET<br>ATTRACTS NORTH SEEKING ATTRACTS NORTH SEEKING ATTRACTS NORTH SEEKING<br>POLE OF COMPASS. POLE OF COMPASS. POLE OF COMPASS.<br>- -<br>- + - +<br>all A AFI PA, gu Ly<br>POLARITY POLARITY POLARITY<br>MARKING MARKING MARKING<br>ae a i<br>Product code structure Typical product code PRD -7 A Y 0 -120<br>Type<br>PRD Open relay<br>PRDA Open relay with aux. 1 form C (CO) snap-action switch<br>Main contact arrangement<br>1 1 form A (1 NO) 3 1 form X (1 NO-DM)<br>5 1 form C (1 CO) 7 2 form A (2 NO)<br>7V 2 form A (2 NO) with 3mm contact gap [1)] 11 2 form C (2 CO)<br>1) Code 7V is only available as a UL Recognized model, not UL Listed<br>Coil input<br>SO A AC, 50/60Hz D DC<br>Main contact material and type<br>Y .312” (7.92mm) dia. Ag [25A max. rating]<br>G .312” (7.92mm) dia. AgCdO [30A max. rating]<br>F .312” (7.92mm) dia. AgCdO [50A max. rating] [2)]<br>H Ag with magnetic blowout [20A DC max. rating] [3)]<br>J AgCdO with magnetic blowout [20A DC max. rating]<br>N W stationary & AgCdO movable [25A max. rating] [4)]<br>P Ag [50A max. rating] [5)]<br>R Ag with magnetic blow out [50A max. rating] [5)]<br>2) Available with Main contact arrangement code 1, 5, 7 or 11 only, and Termination code 0 or A only.<br>**----- End of picture text -----**<br> - 3) Available with Main contact arrangement code 3, 7 or 11 only - 4) Available with Main contact arrangement code 1, 5, 7 or 11 only. - 5) Available with Main contact arrangement code 3 only, and Termination code 4 only. - **Termination PRD types only 0** #8-32 screw term. for main contacts, #6-32 screw term. for coil. **1** .250” (6.35mm) QC for main contacts and coil **3** #8-32 screw term. for main contacts, .250” (6.35mm) QC for coil. **4** Box lug term. which accept #6 - #14 wire for main contacts, #6-32 screw term. for coil.[6)] - 6) Available with Main contact arrangement code 3 only, and Main contact material code P or R only. **PRDA (with aux. switch) types only** **A** #8-32 screw term. for main contacts, #6-32 screw term. for coil, screw term. for aux. switch **B** .250” (6.35mm) QC for main contacts, coil and aux. switch **L** Twin .250” (6.35mm) QC for main contacts, .250” (6.35mm) QC for coil and aux. switch **Coil voltage** Coil code: please refer to coil versions table 3 Catalog and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Catalog product data, ‘Definitions’ section, application notes and all specifications are subject to change. Catalog and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions 06-2015, Rev. 0615 www.te.com © 2015 Tyco Electronics Corporation, a TE Connectivity Ltd. company. General Purpose Panel/Plug-in Relays **Potter & Brumfield** ## **PRD Series Power Relay** (Continued) |PRD-3AY0-120<br>PRD-3AG0-120<br>PRD-3AJ0-120<br>PRD-3AJ3-24<br>PRD-3DH0-24<br>PRD-3DY0-12<br>PRD-3DY0-24<br>PRD-3DY0-110<br>PRD-5AY0-24<br>PRD-5AY0-120<br>PRD-5AY1-120<br>PRD-5AY0-240<br>PRD-5DF0-12<br>PRD-5DY0-12<br>PRD-5DY0-24<br>PRD-7AG0-120<br>PRD-7AY0-24<br>PRD-7AY0-120<br>PRD-7AY0-240<br>PRD-7AY3-120<br>PRD-7DG0-24<br>PRD-7DH0-48<br>PRD-7DY0-12<br>PRD-7DY0-24<br>PRD-11AF0-240<br>PRD-11AG0-24<br>PRD-11AG0-120<br>PRD-11AG0-240<br>PRD-11AH0-120<br>PRD-11AY0-24<br>PRD-11AY0-120<br>PRD-11AY0-240<br>PRD-11AY0-480<br>PRD-11DF0-12<br>PRD-11DF0-110<br>PRD-11DG0-12<br>PRD-11DG0-24<br>PRD-11DH0-12<br>PRD-11DH0-24<br>PRD-11DH0-48<br>PRD-11DH0-110<br>PRD-11DJ0-24<br>PRD-11DY0-12<br>PRD-11DY0-24<br>PRD-11DY0-48<br>PRD-11DY0-110<br>PRDA-11AGA-120<br>PRDA-11AYA-120|1 form X, 1 NO-DM<br>~~—~~|Ag<br>~~po~~<br>|120VAC<br>~~|~~|Screw|7-1393127-9<br>6-1393127-9<br>7-1393127-4<br>7-1393127-5<br>8-1393127-6<br>9-1393127-5<br>9-1393127-6<br>9-1393127-4<br>1393128-6<br>1393128-5<br>1-1393128-1<br>1393128-7<br>2-1423100-4<br>1-1393128-6<br>1-1393128-7<br>9-1393129-5<br>1393130-9<br>1393130-7<br>1-1393130-0<br>1-1393130-2<br>1-1393130-6<br>2-1393130-1<br>2-1393130-8<br>2-1393130-9<br>3-1423100-0<br>1-1393127-1<br>1393127-9<br>1-1393127-2<br>1-1393127-6<br>2-1393127-9<br>2-1393127-6<br>3-1393127-0<br>3-1393127-1<br>2-1423100-2<br>2-1423100-9<br>3-1393127-5<br>3-1393127-8<br>4-1393127-7<br>4-1393127-9<br>5-1393127-0<br>4-1393127-6<br>5-1393127-5<br>6-1393127-1<br>6-1393127-2<br>6-1393127-3<br>6-1393127-0<br>7-1393131-4<br>7-1393131-9| |---|---|---|---|---|---| |||AgCdO,30A<br>~~po~~<br>|||| |||AgCdO, mag blowout<br>~~po~~<br>|||| ||||24VAC<br>24VDC<br>~~|~~<br>~~———~~|Screw /QC|| |||Ag,magblowout<br>~~po~~<br><br>~~———~~||Screw<br>~~————~~|| |||Ag<br>~~po~~<br> <br>~~———~~|12VDC<br>~~|~~<br>~~———~~||| ||||24VDC<br>~~|~~<br>~~po~~<br>~~———~~||| ||||110VDC<br>~~|~~<br>~~po~~<br>~~Po~~<br>~~———~~||| ||1 form C, 1 CO<br>~~— ~~||24VAC<br> ~~|~~<br>~~Po~~<br>~~po~~<br>~~———~~||| ||||120VAC<br>~~po~~<br>~~———~~||| |||||QC<br>~~————~~|| ||||240VAC<br>~~———~~<br>~~|~~|Screw<br>~~————~~|| |||AgCdO,50A<br>~~———~~<br>~~Sj~~|12VDC<br>~~———~~<br>~~|~~<br>~~Sj~~||| |||Ag<br>~~Sj~~|||| ||||24VDC||| ||2 form A, 2 NO<br>~~———~~|AgCdO,30A<br>~~ee~~<br>~~**e**e~~<br>~~———~~|120VAC<br>~~ee~~<br>~~Jo~~<br>~~———~~||| |||Ag<br>~~**e**e~~<br>~~———~~|24VAC<br>~~Jo~~<br>~~———~~||| ||||120VAC<br>~~Jo~~<br>~~———~~||| ||||240VAC<br>~~Jo~~<br>~~Jo~~<br>~~———~~||| ||||120VAC<br>~~Jo~~<br>~~PO~~<br>~~———~~|Screw /QC<br>~~PO~~|| |||AgCdO,30A<br>~~**e**e~~<br>~~———~~|24VDC<br>~~Jo~~<br>~~e~~<br>~~———~~|Screw|| |||Ag,magblowout<br>~~es~~<br>~~———~~|48VAC<br>~~es~~<br>~~———~~||| |||Ag<br>~~———~~|12VDC<br>~~———~~||| ||||24VDC<br>~~———~~||| ||2 form C, 2 CO|AgCdO,50A<br>~~a~~|240VAC<br>~~a~~<br>~~——~~||| |||AgCdO, 30A<br>~~a~~<br>~~a~~|24VAC<br>~~a~~<br>~~a~~<br>~~——~~||| ||||120VAC<br>~~a~~<br>~~——~~<br>~~po~~||| ||||240VAC<br>~~a~~<br>~~——~~<br>~~po~~<br>~~Po~~||| |||Ag,magblowout<br>~~a~~<br>~~es~~<br>~~——~~|120VAC<br>~~a~~<br>~~——~~<br>~~Po~~<br>~~es~~<br>~~Po~~||| |||Ag<br>~~es~~<br>~~——~~<br>~~—~~|24VAC<br>~~——~~<br>~~es~~<br>~~Po~~<br>~~Po~~||| ||||120VAC<br>~~Po~~<br>~~po~~<br>~~Po~~||| ||||240VAC<br>~~po~~<br>~~Po~~||| ||||480VAC<br>~~Po~~<br>~~==~~||| |||AgCdO, 50A<br>~~——~~<br>~~—~~|12VDC<br>~~Po~~<br>~~==~~||| ||||110VDC<br>~~==~~||| |||AgCdO, 30A<br>~~— ~~<br>~~—~~|12VDC<br>~~==~~<br>~~—~~||| ||||24VDC<br> ~~==~~<br>~~—~~<br>~~——~~||| |||Ag, mag blowout<br>~~—~~<br>~~a~~<br>~~J~~|12VDC<br>~~—~~<br>~~a~~<br>~~——~~||| ||||24VDC<br>~~a~~<br>~~——~~<br>~~|~~||| ||||48VDC<br>~~a~~<br>~~——~~<br>~~|~~<br>~~Po~~<br>~~J~~||| ||||110 VDC<br>~~a~~<br>~~——~~<br>~~Po~~<br>~~J~~||| |||AgCdO,magblowout<br>~~a~~<br>~~J~~<br>~~ee~~<br>~~——|~~|24 VDC<br>~~a~~<br>~~——~~<br>~~J~~<br>~~ee~~<br>~~——|~~||| |||Ag<br>~~ee~~<br>~~——|~~|12 VDC<br>~~ee~~<br>~~——|~~||| ||||24 VDC<br>~~——|Po~~||| ||||48 VAC<br>~~——|Po~~<br>~~po~~||| ||||110 VDC<br>~~——|~~<br>~~po~~<br>~~Po~~||| |||AgCdO, 30A<br>~~——|~~<br>~~po~~|120 VAC<br>~~——|~~<br>~~Po~~<br>~~po~~||| ## **PRD accessory** **Product Code** ~~a~~ 35D013 **==> picture [408 x 150] intentionally omitted <==** **----- Start of picture text -----**<br> Description Part Number<br>Metal dust cover enclosure 5-1393158-2<br>35D013 Dust Cover 5.31 MAX. 3.13 MAX.<br>PRD dust cover has a steel base (104.77)4.125 (134.9) (79.5).97<br>with knockouts for 0.5” (12.7mm) dia.conduit and a cover fitted with two (12.7).50 (52.3)2.06 (17.45).687 (2.36).093 (24.64)<br>screws. Fits PRD relays, except with<br>auxiliary contacts. Finished in gray<br>baked enamel. 1.875 1.625 1.50 3.38 MAX.<br>(47.63) (41.28) (38.1) .75 (85.9)<br>(19.1)<br>Mounting:Three No. 10 holes on1.875” (47.63mm) x4.125” (104.77mm) .218 DIA.(5.54)(23.86).937 (65.0)2.56 (130.18)5.125 (20.62).812 4 KNOCKOUT HOLES.88 DIA.(22.4)<br>centers. 3 MTG. HOLES 4 HOLES TAPPED #8-32 2 KNOCKOUT HOLES EACH END<br>Note: Additional unused holes may be present in dust cover base.<br>**----- End of picture text -----**<br> 4 Catalog and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Catalog product data, ‘Definitions’ section, application notes and all specifications are subject to change. Catalog and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions 06-2015, Rev. 0615 www.te.com © 2015 Tyco Electronics Corporation, a TE Connectivity Ltd. company.
Updated at June 5, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →