PMT-24V350W1AK
POWER SUPPLY, AC-DC, 24V, 14.6A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: DELTA ELECTRONICS / POWER
- Product type: AC / DC Enclosed Power Supplies
- Product Range: PMT Series
- No. of Outputs: 1Outputs
- Output Power Max: 350.4W
- Power Supply Approvals: ITE
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 14.6A
- Output Voltage - Output 1: 24V
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 62.18 € |
| Current stock | 25+ |
| Lead time | 7 days |
**TECHNICAL DATASHEET** ## **PMT Panel Mount Power Supply** 24V 350W 1 Phase / PMT-24V350W1A □ ## **PMT** ## **Highlights & Features** - AC input voltage range selectable by switch - Full Aluminium casing for light weight and corrosion resistant handling - Built-in automatic fan speed control circuit - MTBF > 700,000 hrs as per Telcordia SR-332 - Short Circuit / Overvoltage / Overload / Over Temperature Protections ## **Safety Standards** CB Certified for worldwide use **Model Number:** PMT-24V350W1A☐ **Unit Weight:** 0.82 kg (1.81 lb) **Dimensions (L x W x D):** 215 x 115 x 50 mm (8.46 x 4.53 x 1.97 inch) ## **General Description** The PMT-24V350W1A☐ offers a nominal output voltage of 24V with a wide operating temperature range from -10°C to +70°C and can withstand shock and vibration according to IEC 60068-2. In addition to features like overvoltage and overload protections, Delta’s PMT series of panel mount power supplies is unlike many other brands in the same price level. The PMT series is designed for cost competitive markets without compromising the quality of the components and product specifications. The series of products has an expected life time of 10 years and will have no output power de-rating from 100Vac to 132Vac & 200Vac to 264Vac. ## **Model Information** PMT Panel Mount Power Supply |**ModelNumber**||**Input Voltage Range**|**Input Voltage Range**|**Input Voltage Range**|**Rated OutputVoltage**|**Rated OutputVoltage**|**Rated OutputVoltage**||**Rated Output Current**|**Rated Output Current**| |---|---|---|---|---|---|---|---|---|---|---| |PMT-24V350W1A☐||90-132Vac, 180-264Vac|||24Vdc||||14.6A|| |||(Selectable by Switch)||||||||| |**Model Numbering**||||||||||| |**PM**|**T –**||**24V**|**350W**||**1**||**A**||□| |Panel Mount|Product Type||Output Voltage|Output Power||Single Phase||No PFC|No PFC|Connector Type| ||T – Enclosed|||||||||With UL, TUV, CE| |||||||||||K – Front Face| |||||||||||R – Terminal Block*| |||||||||||With UL| |||||||||||G – Front Face| |||||||||||M – Terminal Block*| ## **Model Numbering** **K, G R*, M*** *Options All parameters are specified at 25°C ambient and AC input unless otherwise indicated. 1 **www.DeltaPSU.com (November 2018, Rev. 06)** **TECHNICAL DATASHEET** ## **PMT Panel Mount Power Supply** 24V 350W 1 Phase / PMT-24V350W1A □ ## **Specifications** Input Ratings / Characteristics |**Specifications**<br>Input Ratings / Characteristics|| |---|---| |Nominal Input Voltage|100-120Vac, 200-240Vac(Selectable bySwitch)| |Input Voltage Range|90-132Vac, 180-264Vac(Selectable bySwitch)| |Nominal Input Frequency|50-60Hz| |Input FrequencyRange|47-63Hz| |Input Current|< 7.00A @ 115Vac, < 4.00A @ 230Vac| |Efficiencyat 100% Load|> 87.0%@230Vac| |Max Inrush Current(Cold Start)|< 50A@115Vac, < 60A@230Vac| |Leakage Current|< 3.5mA@240Vac| ## Output Ratings / Characteristics* |Output Ratings / Characteristics*|| |---|---| |Nominal Output Voltage|24Vdc| |FactorySet Point Tolerance|24Vdc ± 2%| |Output Voltage Adjustment Range|20.0-26.4Vdc| |Output Current|14.6A(350.4W max.)| |Output Power|350.4W| |Line Regulation|± 0.5% typ.| |Load Regulation|± 0.5% typ.| |PARD**(20MHz)|< 150mVpp| |Rise Time|< 50ms@nominal input(100% load)| |Start-up Time|< 1000ms @ nominal input (100% load)| |Hold-up Time|> 16ms@115Vac, > 20ms@230Vac(100% load)| |Dynamic Response (Overshoot & Undershoot O/P Voltage)|± 5% @ 10-50% load and 50-100% load| |Start-upwith Capacitive Loads|8,000µF Max| *For power de-rating from 50°C to 70°C, see power de-rating on page 3. **PARD is measured with an AC coupling mode, 5cm wires, and in parallel with 0.1µF ceramic capacitor & 47µF electrolytic capacitor. ## Mechanical |Mechanical||| |---|---|---| |Case Chassis / Cover||Aluminium| |Dimensions (L x W x D)||215 x 115 x 50 mm (8.46 x 4.53 x 1.97 inch)| |Unit Weight||0.82 kg (1.81 lb)| |Indicator||Green LED(DC OK)| |CoolingSystem||Forced Cooling| |Terminal|PMT-24V350W1AK<br>PMT-24V350W1AG|M3.5 x 9 Pins (Rated 300V/20A)| ||PMT-24V350W1AR<br>PMT-24V350W1AM|M3.5 x 9 Pins (Rated 300V/15A)| |Wire||AWG 20-12| |Noise(1 Meter frompower supply)||Sound Pressure Level(SPL)< 52dBA| **==> picture [101 x 32] intentionally omitted <==** All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 06)** 2 **TECHNICAL DATASHEET** ## **PMT Panel Mount Power Supply** 24V 350W 1 Phase / PMT-24V350W1A □ ## Environment |Environment||| |---|---|---| |Surrounding Air Temperature|Operating|-10°C to +70°C| ||Storage|-25°C to +85°C| |Power De-rating||> 50°C de-rate power by 2.5% / °C<br>< 100Vac de-rate power by 3% / V<br><200Vac de-rate power by 3% / V| |OperatingHumidity||5 to 95% RH(Non-Condensing)| |OperatingAltitude||0 to 5,000 Meters(16,400 ft.)| |Shock Test|Non-Operating|IEC 60068-2-27, Half Sine: 50G for a duration of 11ms, 3 times<br>per direction, 18 times in total| |Vibration|Operating|IEC 60068-2-6, Sine Wave: 10Hz to 150Hz @ 25m/S² (2.5G<br>peak); 90 min per axis for all X, Y, Z direction| ||Non-Operating|IEC 60068-2-6, Random: 5Hz to 500Hz @ 2.09Grms peak; 20<br>min per axis for all X, Y, Z direction| |Over Voltage Category||II| |Pollution Degree||2| ## Protections |Protections|| |---|---| |Overvoltage|< 32.4V, SELV Output, Latch Mode| |Overload / Overcurrent|< 25A of rated load current, Hiccup Mode,<br>Non-Latching (Auto-Recovery)| |Over Temperature|Hiccup Mode, Non-Latching<br>(Auto-Recovery when the fault is removed)| |Short Circuit|Hiccup Mode, Non-Latching<br>(Auto-Recovery when the fault is removed)| |Internal Fuse at L pin|T10AH| |Protection Against Shock|Class I with PE* connection| *PE: Primary Earth ## Reliability Data |Reliability Data||| |---|---|---| |MTBF||> 700,000 hrs as per Telcordia SR-332<br>I/P: 100Vac, O/P: 100% load, Ta: 35°C| |Expected CapLife Time||10years(115Vac & 230Vac, 50% load@40°C)| **==> picture [101 x 32] intentionally omitted <==** All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 06)** 3 **TECHNICAL DATASHEET** **PMT Panel Mount Power Supply** 24V 350W 1 Phase / PMT-24V350W1A □ ## Safety Standards / Directives |Safety Standards / Directives||| |---|---|---| |SafetyEntryLow Voltage||SELV(EN 60950-1)| |Electrical Safety|TUV Bauart<br>UL/cUL recognized<br>CB scheme<br>UL/cUL recognized<br>CB scheme|**PMT-24V350W1AK/ PMT-24V350W1AR:**<br>EN 60950-1<br>UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E131881)<br>IEC 60950-1<br>**PMT-24V350W1AG/ PMT-24V350W1AM:**<br>UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E131881)<br>IEC 60950-1| |CE||**PMT-24V350W1AK / PMT-24V350W1AR: **<br>In conformance with EMC Directive 2014/30/EU and<br>Low Voltage Directive 2014/35/EU| |Material and Parts||RoHS Directive 2011/65/EU Compliant| |Galvanic Isolation|Input to Output|3.0KVac| ||Input to Ground|1.5KVac| ||Output to Ground|0.5KVac| ## EMC |Emissions (CE & RE)||**PMT-24V350W1AK / PMT-24V350W1AR: **<br>CISPR 32, EN 55032, EN 55011, FCC Title 47: Class B<br>**PMT-24V350W1AG/ PMT-24V350W1AM:**<br>CISPR 32, EN 55032, FCC Title 47: Class A<br>(With Delta EMI filter P/N: 10DKAW5)| |---|---|---| |Immunity||EN 55024| |Electrostatic Discharge|IEC 61000-4-2|Level 4 Criteria A1)<br>Air Discharge: 15kV<br>Contact Discharge:8kV| |Radiated Field|IEC 61000-4-3|Level 3 Criteria A1)<br>80MHz-1GHz, 10V/M with 1kHz tone / 80% modulation| |Electrical Fast Transient / Burst|IEC 61000-4-4|Level 3 Criteria A1)<br>2kV| |Surge|IEC 61000-4-5|Level 3 Criteria A1)<br>Common Mode2): 2kV<br>Differential Mode3): 1kV| |Conducted|IEC 61000-4-6|Level 3 Criteria A1)<br>150kHz-80MHz, 10Vrms| |Power Frequency Magnetic Fields|IEC 61000-4-8|Criteria A1)<br>10A/Meter| |Voltage Dips and Interruptions|IEC 61000-4-11|100% dip; 1 cycle (20ms); Self Recoverable| |Low Energy Pulse Test (Ring<br>Wave)|IEC 61000-4-12|Level 3 Criteria A1)<br>Common Mode2): 2kV<br>Differential Mode3): 1kV| |Harmonic Current Emission||NA| |Voltage Fluctuation and Flicker*||**PMT-24V350W1AK/ PMT-24V350W1AR:**<br>IEC/EN 61000-3-3| - *Fulfills tested conditions - 1) Criteria A: Normal performance within the specification limits - 2) Asymmetrical: Common mode (Line to earth) - 3) Symmetrical: Differential mode (Line to line) **==> picture [101 x 32] intentionally omitted <==** All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 06)** 4 **TECHNICAL DATASHEET** ## **PMT Panel Mount Power Supply** 24V 350W 1 Phase / PMT-24V350W1A □ ## **Block Diagram** ## **Device Description** **PMT-24V350W1AK / PMT-24V350W1AG:** Front Face **PMT-24V350W1AR / PMT-24V350W1AM:** Terminal Block - 1) Input & Output terminal block connector - 2) DC voltage adjustment potentiometer - 3) DC OK control LED (Green) - 4) AC selectable switch All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 06)** 5 **TECHNICAL DATASHEET** ## **PMT Panel Mount Power Supply** 24V 350W 1 Phase / PMT-24V350W1A □ ## **Dimensions** PMT-24V350W1AK / PMT-24V350W1AG: Front Face **L x W x D:** 215 x 115 x 50 mm (8.46 x 4.53 x 1.97 inch) All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 06)** 6 **TECHNICAL DATASHEET** ## **PMT Panel Mount Power Supply** 24V 350W 1 Phase / PMT-24V350W1A □ PMT-24V350W1AR / PMT-24V350W1AM: Terminal Block **L x W x D:** 215 x 115 x 50 mm (8.46 x 4.53 x 1.97 inch) All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 06)** 7 **TECHNICAL DATASHEET** ## **PMT Panel Mount Power Supply** 24V 350W 1 Phase / PMT-24V350W1A □ ## **Engineering Data** Output Load De-rating VS Surrounding Air Temperature ## **Note** 1. Power supply components may degrade, or be damaged, when the power supply is continuously used outside the shaded region, refer to the graph shown in Fig. 1. 2. If the output capacity is not reduced when the surrounding air temperature exceeds its specification as defined on Page 3 under “Environment”, the device will run into Over Temperature Protection. When activated, the output voltage will go into bouncing mode and will recover when the surrounding air temperature is lowered or the load is reduced as far as necessary to keep the device in working condition. 3. In order for the device to function in the manner intended, it is also necessary to keep a safety distance of ≥ 20 mm (0.79 inch) with adjacent units while the device is in operation. ## **Fig. 1 De-rating for Vertical and Horizontal Mounting Orientation** > 50°C de-rate power by 2.5% / °C 4. Depending on the surrounding air temperature and output load delivered by the power supply, the device housing can be very hot! 5. If the device has to be mounted in any other orientation, please contact **info@deltapsu.com** for more details. Output Load De-rating VS Input Voltage - No output power de-rating for the input voltage from 100Vac to 132Vac & 200Vac to 264Vac All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 06)** 8 **TECHNICAL DATASHEET** ## **PMT Panel Mount Power Supply** 24V 350W 1 Phase / PMT-24V350W1A □ ## **Assembly & Installation** - Ⓐ Side Mounting: Fig. 2 and Fig. 3 show the mounting hole locations for power supply assembly onto a metal mounting surface. The power supply shall be mounted on minimum of 4 mounting holes using M4 screw maximum 5 mm (0.20 inch) length (Refer to Fig. 4). This is to maintain a safety distance between the screw and internal components. - Ⓑ Base Mounting: Fig. 2 and Fig. 3 show the mounting hole locations for power supply assembly onto a metal mounting surface. The power supply shall be mounted on minimum of 4 mounting holes using M4 screw maximum 4 mm (0.16 inch) length (Refer to Fig. 4). - Ⓒ Connector - Ⓓ This surface belongs to customer’s end system or panel where the power supply is mounted. **==> picture [495 x 142] intentionally omitted <==** **----- Start of picture text -----**<br> Base Mounting (Horizontal) Base Mounting (Vertical) Side Mounting (Horizontal)<br>es \ > \ je<br>_——, — rr<br>——— ONY \ Der reer<br>QE ¢<br>Fig. 2 Recommended Mounting Orientations<br>**----- End of picture text -----**<br> - Use flexible cable (stranded or solid) of AWG No. 20-12. The input/output connectors’ allowable current is 23A max per pin. User should calculate and select the suitable wire specification (type/quantity/diameter) according to actual output current. The torque at the connector shall not exceed 13 Kgf.cm (11.23 lbf.in). The insulation stripping length should not exceed 0.275” or 7 mm. - • Recommended mounting torque of the product and its mounting accessories is 9~12 Kgf.cm (7.81~10.42 lbf.in). HOLE bi **Safety Distance** D1 = 4mm Min. D2 = 20mm Min **.** @) MOUNTING HOLE I} Ee **Fig. 3 Mounting Hole Locations** Ensure the mounted device is kept at ≥ 4 mm (0.16 inch) safety distance at all sides from other components and equipments. In addition, to ensure sufficient convection cooling, always maintain a distance of ≥ 20 mm (0.79 inch) from fan ventilated surfaces while the device is in operation. Please insert an insulation sheet between the system and product, if the safety distance is < 4mm (0.16 inch). - Only use M4 screw ≤ 5 mm (0.20 inch) through the base mounting holes at Ⓐ _._ This is to keep a safe distance between the screw and internal components. - Only use M4 screw ≤ 4 mm (0.16 inch) through the base mounting holes at Ⓑ _._ This is to keep a safe distance between the screw and internal components. **Fig. 4 Assembly Reference** All parameters are specified at 25°C ambient and AC input unless otherwise indicated. | **www.DeltaPSU.com (November 2018, Rev. 06)** 9 **TECHNICAL DATASHEET** **PMT Panel Mount Power Supply** 24V 350W 1 Phase / PMT-24V350W1A □ ## Safety Instructions - Must select correct AC input voltage before turning on (Refer to the “Device Description” on Page 5). - If user’s mounting orientation is not according to the recommended mounting orientations, please consult Delta for further information. - The device is not recommended to be placed on low thermal conductive surface. For example, plastics. - The enclosure of the device can become very hot depending on the ambient temperature and load of the power supply. Do not touch the device while it is in operation or immediately after power is turned OFF. Risk of burning! - Do not touch the terminals while power is being supplied. Risk of electric shock. - Prevent any foreign metal, particles or conductors from entering the device through the openings during installation. It may cause electric shock, safety hazard, fire and/or product failure. - Warning: When connecting the device, secure Earth connection before connecting L and N. When disconnecting the device, remove L and N connections before removing the Earth connection. The power supply must be mounted by metal screws onto a grounded metal surface. It is highly recommended that the Earth terminal on the connector be connected to the grounded metal surface. ## **Accessories** ## LM-01: Top Fixing Bracket This bracket is used to fix the power supply onto a flat surface from the top. **==> picture [185 x 42] intentionally omitted <==** **----- Start of picture text -----**<br> •<br>•<br>oS a<br>**----- End of picture text -----**<br> All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 06)** 10 **TECHNICAL DATASHEET** **PMT Panel Mount Power Supply** 24V 350W 1 Phase / PMT-24V350W1A □ ## **Functions** ## Start-up Time The time required for the output voltage to reach 90% of its final steady state set value, after the input voltage is applied. ## Rise Time The time required for the output voltage to change from 10% to 90% of its final steady state set value. ## Hold-up Time Time between the collapse of the AC input voltage, and the output falling to 95% of its steady state set value. ## ■ **Graph illustrating the Start-up Time, Rise Time, and Hold-up Time** ## Inrush Current Inrush current is the peak, instantaneous, input current measured and, occurs when the input voltage is first applied. For AC input voltages, the maximum peak value of inrush current will occur during the first half cycle of the applied AC voltage. This peak value decreases exponentially during subsequent cycles of AC voltage. ## Dynamic Response The power supply output voltage will remain within ±1000mVpp of its steady state value, when subjected to a dynamic load from 10 to 50% and 50 to 100% of its rated current. ## ■ **50% duty cycle / 5Hz to 100Hz** All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 06)** 11 **TECHNICAL DATASHEET** **PMT Panel Mount Power Supply** 24V 350W 1 Phase / PMT-24V350W1A □ ## Overload & Overcurrent Protections (Auto-Recovery) The power supply’s Overload (OLP) and Overcurrent (OCP) Protections will be activated when output current exceeds >25A of rated load current. In such occurrence, the VO will start to droop and once the power supply has reached its maximum power limit, the protection is activated and the power supply will go into “Hiccup mode” (Auto-Recovery). The power supply will recover once the fault condition of the OLP and OCP is removed and IO is back within the specifications. ## Overvoltage Protection (Latch Mode) The power supply’s overvoltage circuit will be activated when its internal feedback circuit fails. The output voltage shall not exceed its specifications defined on Page 3 under “Protections”. Power supply will latch, and require removal/re-application of input AC voltage in order to restart. ## **The power supply should be latch.** ## Over Temperature Protection (Auto-Recovery) It is not recommended to prolong the duration of IO when it is <25A but >14.6A, since it may cause damage to the PSU. ## Short Circuit Protection (Auto-Recovery) The power supply’s output OLP/OCP function also provides protection against short circuits. When a short circuit is applied, the output current will operate in “Hiccup mode”, as shown in the illustration in the OLP/OCP section on this page. The power supply will return to normal operation after the short circuit is removed. As described in load de-rating section, the power supply also has Over Temperature Protection (OTP). In the event of a higher operating temperature at 100% load, the power supply will run into OTP when the operating temperature is beyond what is recommended in the de-rating graph. When activated, the output voltage will go into bouncing mode until the temperature drops to its normal operating temperature as recommended in the derating graph. All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 06)** 12 **TECHNICAL DATASHEET** **PMT Panel Mount Power Supply** 24V 350W 1 Phase / PMT-24V350W1A □ ## Operating Mode ## **Redundant Operation** In order to ensure proper redundant operation for the power supply units (PSUs), the output voltage difference between the two units must be kept at 0.45~0.50V for these 24V supplies. Follow simple steps given below to set them up for the redundant operation: ## **Step 1.** Measure output voltage of PSU 1 and PSU 2. If PSU 1 is the master unit, then VO of PSU 1 must be higher than PSU 2. In order to set the output voltage, individually connect each power supply to 50% of rated load at any line voltage from 85-264Vac, and set the PSU 1 and PSU 2 output voltage. ## **Step 2.** Connect the power supply units PSU 1 and PSU 2 to Vin 1 & Vin 2, respectively, of the DRR-20N (or 20A) module shown on the right of above diagram. **==> picture [270 x 132] intentionally omitted <==** **----- Start of picture text -----**<br> PSU 1 PSU 2 DRR-40N or<br>DRR-40A<br>FX PX 11<br>OA leet TerminalLOAD 7 Com<br>0000000 0000000 a x CI<br>KEY<br>+ Output PSU 1<br>+ Output PSU 2<br>L (L1) H | Terminal NDC OKSignal – Common Signal<br>N (L2)PE<br>**----- End of picture text -----**<br> ## **Fig. 5 Redundant Operation Connection Diagram** ## **Step 3.** Connect the system load to Vout. Please note that output voltage Vout from DRR module will be = VO (output voltage of power supply) – Vdrop* (in DRR module). *Vdrop will vary from 0.60V to 0.90V (Typical 0.65V) depending on the load current and surrounding air temperature ## **Parallel Operation** The power supply units (PSUs) can also be used for parallel operation in order to increase the output power. The difference in output voltage between the two units must be kept to within 25mV of each other. This difference must be verified with the same output load connected independently to each unit. Parameters such as EMI, inrush current, leakage current, PARD, start up time will be different from those on the datasheet, when two units are connected in parallel. The user will need to verify that any differences will still allow the two power supplies connected in parallel will work properly in their product/application. ## **Fig. 6 Parallel Operation Connection Diagram** All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 06)** 13 **TECHNICAL DATASHEET** ## **PMT Panel Mount Power Supply** 24V 350W 1 Phase / PMT-24V350W1A □ ## **Others** ## Delta RoHS Compliant ## **Restriction of the usage of hazardous substances** **==> picture [42 x 46] intentionally omitted <==** The European directive 2011/65/EU limits the maximum impurity level of homogeneous materials such as lead, mercury, cadmium, chrome, polybrominated flame retardants PBB and PBDE for the use in electrical and electronic equipment. RoHS is the abbreviation for “Restriction of the use of certain hazardous substances in electrical and electronic equipment”. This product conforms to this standard. ## Attention Delta provides all information in the datasheets on an “AS IS” basis and does not offer any kind of warranty through the information for using the product. In the event of any discrepancy between the information in the catalog and datasheets, the datasheets shall prevail (please refer to www.DeltaPSU.com for the latest datasheets information). Delta shall have no liability of indemnification for any claim or action arising from any error for the provided information in the datasheets. Customer shall take its responsibility for evaluation of using the product before placing an order with Delta. Delta reserves the right to make changes to the information described in the datasheets without notice. **==> picture [101 x 32] intentionally omitted <==** All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 06)** 14
Updated at February 9, 2023
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →