PMH-24V100WCAA
POWER SUPPLY, AC-DC, 24V, 4.16A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: DELTA ELECTRONICS
- Product type: AC / DC Enclosed Power Supplies
- Power Supply Applications:ITE & Household; No. of Outputs:1Outputs; Output Power Max:100W; Output Voltage - Output 1:24V; Output Current - Output 1:4.16A; Output Volta 52AH7532
- No. of Outputs: 1Outputs
| Delivery and price | |
|---|---|
| Units per pack | 25 |
| Price | 29.24 € |
| Current stock | 10+ |
| Lead time | 30 days |
**TECHNICAL DATASHEET** ## **PMH Panel Mount Power Supply** 24V 100W 1 Phase / PMH-24V100WC ## **PMH** ## **Highlights & Features** - Household appliance approvals IEC/EN 60335-1, IEC/EN 61558-1 and IEC/EN 61558-2-16 - Universal AC input voltage - Full power from -20°C to +50°C operation @ 5000m or 16400 ft. altitude - Full corrosion resistant aluminium casing - No load power consumption < 0.5W - High MTBF > 700,000 hrs as per Telcordia SR-332 - Versatile connector options available: IP20, Front Face and Harness connectors ## **Safety Standards** CB Certified for worldwide use **Model Number:** PMH-24V100WC `☐☐` **Unit Weight:** 0.43 kg (0.95 lb) **Dimensions (L x W x D):** 158 x 97 x 38 mm (6.22 x 3.82 x 1.50 inch) ## **General Description** The PMH-24V100WC `☐☐` offers universal input from 85Vac to 264Vac with nominal output voltage of 24V. The highly efficient convection cooling construction can operate from -30°C to 70°C. The PMH series is specifically designed for household electrical appliances with safety approvals including IEC/EN 60335-1 and IEC/EN 61558-2-16, as well as IEC/EN/UL 60950-1. In addition, the product meets the EMC approvals to EN 55014-1 / EN 55014-2 for household appliances and EN 61000-6-1 / EN 61000-6-3 for residential environment without extra EMI filter required and comes with several connector options consisting of Terminal Block, IP20, Front Face and Harness connectors. Other available options include isolation or non-isolation between Primary Earth and output DC Return (-V pins on output connector). ## **Model Information** PMH Panel Mount Power Supply |**ModelNumber**|**ModelNumber**|**Input Voltage Ran**|**e Range**|**e Range**|**Rated Output**|**Rated Output**|**Voltage**|**Rated Out**|**Rated Output Current**| |---|---|---|---|---|---|---|---|---|---| |PMH-24V100WC☐☐||85-264Vac(120-375Vdc)|||24Vdc|||4.16A|4.16A| |**Model Numbering**|||||||||| |**PM**|**H –**|**24V**||**100W**||**C**|.||| |Panel Mount|Product Type|Output Voltage|Output Voltage|Output Power|Output Power|Package Type<br>A – PD2 + No PFC|||Connector Type and| ||H – Household<br>Series|||||C – Enclosed|C – Enclosed<br>C – PD3 + No PFC||Primary Earth to Output DC<br>Return Connection.<br>See options in table below| ||||||||||| ||a)||||**Connector Type **<br>Terminal Block<br>IP20 Connector*<br>Front Face*<br>Harness*||**Output non-isolated to PE**<br>**Output isolated to PE**<br>A<br>S<br>J<br>U<br>L<br>V<br>H<br>T||| |**A, S J, U L, V H, T**|**A, S J, U L, V H, T**|**A, S J, U L, V H, T**|**A, S J, U L, V H, T**|**A, S J, U L, V H, T**|*Options||||| ## **Model Numbering** All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (December 2018, Rev. 06)** 1 **TECHNICAL DATASHEET** **PMH Panel Mount Power Supply** 24V 100W 1 Phase / PMH-24V100WC ## **Specifications** Input Ratings / Characteristics |Input Ratings / Characteristics|Input Ratings / Characteristics|| |---|---|---| |Nominal Input Voltage||100-240Vac| |Input Voltage Range||85-264Vac| |Nominal Input Frequency||50-60Hz| |Input FrequencyRange||47-63Hz| |Nominal DC Input Voltage||125-250Vdc| |DC Input Voltage Range||120-375Vdc| |Input Current||< 1.90A @ 115Vac, < 1.10A @ 230Vac| |Efficiency at 100% Load||> 87.0% @ 115Vac, > 89.0% @ 230Vac| |Max Power Dissipation|0% load|< 0.5W @ 115Vac & 230Vac| ||100% load|15.0W typ. @ 115Vac & 12.2W typ. @ 230Vac| |Max Inrush Current(Cold Start)||< 50A @ 115Vac, < 100A @ 230Vac| |Leakage Current|PMH-24V100WCA☐|< 1.2mA @ 240Vac| ||PMH-24V100WCC☐|< 0.5mA @ 240Vac| Output Ratings / Characteristics* |Output Ratings / Characteristics*|| |---|---| |Nominal Output Voltage|24Vdc| |FactorySet Point Tolerance|24Vdc ± 2%| |Output Voltage Adjustment Range|22-28Vdc| |Output Current|4.16A(100W max.)| |Output Power|100W| |Line Regulation|< 0.5%(@ 85-264Vac input, 100% load)| |Load Regulation|< 1.0% (@ 85-264Vac input, 0-100% load)| |PARD**(20MHz)|< 100mVpp| |Rise Time|< 20ms @ nominal input (@ -20°C to 70°C)<br>< 30ms @ nominal input(@ < -20°C to -30°C)| |Start-up Time|< 1300ms @ 100Vac (100% load)<br>< 750ms @ 240Vac (100% load)| |Hold-upTime|> 15ms@115Vac,> 100ms@230Vac(100% load)| |Dynamic Response (Overshoot & Undershoot O/P Voltage)|± 5% @ 85-264Vac input, 0-100% load<br>(Slew Rate: 0.1A/μS, 50% duty cycle @ 5Hz to 1KHz)| |Start-upwith Capacitive Loads|8,000µF Max| *For power de-rating from < -20°C to -30°C, and 50°C to 70°C, see power de-rating on page 3. **PARD is measured with an AC coupling mode, 5cm wires, and in parallel with 0.1µF ceramic capacitor & 47µF electrolytic capacitor. All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (December 2018, Rev. 06)** 2 **TECHNICAL DATASHEET** **PMH Panel Mount Power Supply** 24V 100W 1 Phase / PMH-24V100WC ## Mechanical |Mechanical|Mechanical|| |---|---|---| |Case Chassis / Cover||Aluminium| |Dimensions (L x W x D)||158 x 97 x 38 mm (6.22 x 3.82 x 1.50 inch)| |Unit Weight||0.43 kg (0.95 lb)| |Indicator||Green LED(DC OK)| |CoolingSystem||Convection| |Terminal|PMH-24V100WC☐S (A)|M3.5 x 7 Pins(Rated 300V/15A)| ||PMH-24V100WC☐U (J)|M3.5 x 7 Pins(Rated 300V/20A)| ||PMH-24V100WC☐V (L)|M3.5 x 7 Pins(Rated 300V/20A)| ||PMH-24V100WC☐T(H)|Input: B3P(6-2.3.5)-VH(LF)(SN)<br>Output: B4P7-VH(LF)(SN)| |Wire|PMH-24V100WC☐S (A)|AWG 20-14| ||PMH-24V100WC☐U (J)|AWG 20-12| ||PMH-24V100WC☐V (L)|| |Noise(1 Meter frompower supply)||Sound Pressure Level(SPL)< 25dBA| ## Environment |Environment||| |---|---|---| |Surrounding Air Temperature|Operating|-30°C to +70°C| ||Storage|-30°C to +85°C| |Power De-rating||-20°C to -30°C de-rate power by 2.0% / °C<br>> 50°C de-rate power by 2.5% / °C| |OperatingHumidity||5 to 95% RH(Non-Condensing)| |OperatingAltitude||0 to 5,000 Meters(16,400 ft.)| |Shock Test|Non-Operating|IEC 60068-2-27, 30G (300m/S²) for a duration of 18ms,1 times<br>per direction, 2 times in total| |Vibration|Non-Operating|IEC 60068-2-6, 10Hz to 150Hz @ 50m/S² (5G peak);<br>displacement of 0.35mm; 20 min per axis for all X, Y, Z<br>direction| |Bump|Operating|IEC 60068-2-29, 10G (100m/S²) for a duration of 11ms,1000<br>timesper direction, 6000 times in total| |Over Voltage Category||II| |Pollution Degree|PMH-24V100WCA☐|2| ||PMH-24V100WCC☐|3| All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (December 2018, Rev. 06)** 3 **TECHNICAL DATASHEET** **PMH Panel Mount Power Supply** 24V 100W 1 Phase / PMH-24V100WC ## Protections |Protections|| |---|---| |Overvoltage|28.8-35.2V range, Hiccup Mode,<br>Non-Latching (Auto-Recovery)| |Overload / Overcurrent|> 120% of rated load current, Hiccup Mode,<br>Non-Latching (Auto recovery)| |Over Temperature|< 75°C Surrounding Air Temperature @ 100% load,<br>Non-Latching (Auto-recovery)| |Short Circuit|Hiccup Mode, Non-Latching<br>(Auto-recovery when the fault is removed).| |Internal Fuse at L pin|T3.15AH| |Degree of Protection|IP20(PMH-24V100WC☐Uand PMH-24V100WC☐J)| |Protection Against Shock|Class I with PE* connection| *PE: Primary Earth ## Reliability Data |Reliability Data|| |---|---| |MTBF|> 700,000 hrs. as per Telcordia SR-332<br>I/P: 115Vac,O/P: 100% load,Ta: 25°C| |Expected CapLife Time|10years(115Vac & 230Vac,50% load@40°C)| Safety Standards / Directives |Safety Standards / Directives||| |---|---|---| |Safety Entry Low Voltage|Output non-isolated to PE<br>Output isolated to PE|PELV (EN 60335), SELV (EN 60950)<br>SELV(EN 60335), SELV(EN 60950)| |Electrical Safety|SIQ Bauart|EN 60950-1, EN 60335-1, EN 61558-1, EN 61558-2-16| ||UL/cUL recognized|UL 60950-1 and CSA C22.2 No. 60950-1(File No. E191395)| ||CB scheme|IEC 60950-1, IEC 60335-1, IEC 61558-1, IEC 61558-2-16| |CE||In conformance with EMC Directive 2014/30/EU and Low<br>Voltage Directive 2014/35/EU| |Material and Parts||RoHS Directive 2011/65/EU Compliant| |Galvanic Isolation|Input to Output|4.2KVac| ||Input to Ground|1.5KVac| ||Output to Ground|Output non-isolated to PE (common pins connect to PE)<br>(PMH-24V100WC☐A, PMH-24V100WC☐J,<br>PMH-24V100WC☐L,PMH-24V100WC☐H)<br>1.5KVdc (Output isolated to PE)<br>(PMH-24V100WC☐S, PMH-24V100WC☐U,<br>PMH-24V100WC☐V, PMH-24V100WC☐T)| All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (December 2018, Rev. 06)** 4 **TECHNICAL DATASHEET** **PMH Panel Mount Power Supply** 24V 100W 1 Phase / PMH-24V100WC ## EMC |EMC||| |---|---|---| |Emissions (CE & RE)|CISPR 32, EN 55032, FCC Title 47: Class B,<br>EN 55014-1, EN 61000-6-3|| |Immunity|EN 55024, EN 61000-6-1, EN 55014-2|| |Electrostatic Discharge<br>IEC 61000-4-2|Level 4 Criteria A1)<br>Air Discharge: 15kV<br>Contact Discharge: 8kV|| |Radiated Field<br>IEC 61000-4-3|Level 3 Criteria A1)<br>80MHz-1GHz, 10V/M with 1kHz tone / 80% modulation<br>1.4GHz-2GHz, 3V/M with 1kHz tone / 80% modulation<br>2GHz-2.7GHz, 1V/M with 1kHz tone / 80% modulation|| |Electrical Fast Transient / Burst<br>IEC 61000-4-4|Level 3 Criteria A1)<br>2kV|| |Surge<br>IEC 61000-4-5|Level 3 Criteria A1)<br>Common Mode3): 2kV<br>Differential Mode4): 1kV|| |Conducted<br>IEC 61000-4-6|Level 3 Criteria A1)<br>150kHz-80MHz, 10Vrms|| |Power Frequency Magnetic Fields<br>IEC 61000-4-8|Criteria A1)<br>30A/Meter|| |Voltage Dips and Interruptions<br>IEC 61000-4-11|0% of 100Vac, 20ms<br>40% of 100Vac, 200ms<br>70% of 100Vac, 500ms<br>0% of 100Vac, 5000ms<br>0% of 240Vac, 20ms<br>40% of 240Vac, 200ms<br>70% of 240Vac, 500ms<br>0% of 240Vac, 5000ms|Criteria A1)<br>Criteria A1)<br>Criteria A1)<br>Criteria B2)<br>Criteria A1)<br>Criteria A1)<br>Criteria A1)<br>Criteria B2)| |Low Energy Pulse Test (Ring Wave)<br>IEC 61000-4-12|Level 3 Criteria A1)<br>Common Mode3): 2kV<br>Differential Mode4): 1kV|| |Harmonic Current Emission|IEC/EN 61000-3-2,Class A|| |Voltage Fluctuation and Flicker|IEC/EN 61000-3-3|| - 1) Criteria A: Normal performance within the specification limits - 2) Criteria B: Temporary degradation or loss of function which is self-recoverable - 3) Asymmetrical: Common mode (Line to earth) - 4) Symmetrical: Differential mode (Line to line) All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (December 2018, Rev. 06)** 5 **TECHNICAL DATASHEET** ## **PMH Panel Mount Power Supply** 24V 100W 1 Phase / PMH-24V100WC ## **Block Diagram** ## **Device Descriptions** |**Device Descriptions**|| |---|---| |**PMH-24V100WC**☐**S (A):**Terminal Block|**PMH-24V100WC**☐**U (J):**IP20 Terminal Block| |Ventilatedsurface<br>-<br>Sidesurface<br>pesSSSSsSsene<br>i<br>SOOSSRSasa<br>un<br>RORSSESSSSsSSs.<br>“ =<br>||eO<br>Basesurface<br>\ge oO|**PMH-24V100WC**☐**V (L):**Front Face<br>**PMH-24V100WC**☐**T (H):**Harness<br>‘\eege ee)<br>3)<br>ces eeerts|<br>ee<br>oO<br>eet<br>——<LAMa]<br>es<br>O~~e~~<br>J ==FIN<br>meal<br>@| - 1) Input & Output terminal block connector 2) DC voltage adjustment potentiometer (22V – 28V) - 3) DC OK control LED (Green) All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (December 2018, Rev. 06)** 6 **TECHNICAL DATASHEET** ## **PMH Panel Mount Power Supply** 24V 100W 1 Phase / PMH-24V100WC ## **Dimensions** **L x W x D:** 158 x 97 x 38 mm (6.22 x 3.82 x 1.50 inch) (PMH-24V100WC `☐` S (A): Terminal Block) ## **Engineering Data** Output Load De-rating VS Surrounding Air Temperature ## **Note** 1. Power supply components may degrade, or be damaged, when the power supply is continuously used outside the shaded region, refer to the graph shown in Fig. 1. 2. If the output capacity is not reduced when surrounding air temperature exceeds its specification as defined on Page 3 under “Environment”, the device will run into Over Temperature Protection. When activated, the output voltage will go into bouncing mode and will recover when the surrounding air temperature is lowered or the load is reduced as far as necessary to keep the device in working condition. 3. In order for the device to function in the manner intended, it is also necessary to keep a safety distance as recommended in the safety instructions while the device is in operation. ## **Fig. 1 De-rating for Vertical and Horizontal Mounting Orientation** -20°C to -30°C de-rate power by 2.0% / °C > 50°C de-rate power by 2.5% / °C 4. Depending on the surrounding air temperature and output load delivered by the power supply, the device can be very hot! 5. If the device has to be mounted in any other orientation, please contact **info@deltapsu.com** for more details. All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (December 2018, Rev. 06)** 7 **TECHNICAL DATASHEET** ## **PMH Panel Mount Power Supply** 24V 100W 1 Phase / PMH-24V100WC ## Output Load De-rating VS Input Voltage - No output power de-rating across the entire input voltage range ## **Assembly & Installation** - Ⓐ Mounting holes for power supply assembly onto the mounting surface. The power supply shall be mounted on minimum 2 mounting holes using M3 screw minimum 5mm length. - Ⓑ This surface belongs to customer’s end system or panel where the power supply is mounted. - Ⓒ Connector **==> picture [458 x 216] intentionally omitted <==** **----- Start of picture text -----**<br> Side Mounting (Vertical) Base Mounting (Vertical) Side Mounting (Horizontal)<br>mae od (A)<br>U ~) ©@® —S ee<br>. amr<br>.<br>y, & woccseueeuee<br>=<br>Fig. 2 Mounting Orientation<br>**----- End of picture text -----**<br> - Use flexible cable (stranded or solid) with the following sizes: |**PMH-24V100WC**☐**S(A)**|**PMH-24V100WC**☐**U(J)**|**PMH-24V100WC**☐**V(L)**| |---|---|---| |AWG 20-14|AWG 20-12|AWG 20-12| - The torque at the Connector shall not exceed 13Kgf.cm (11.23 lbf.in). The insulation stripping length should not exceed 0.275” or 7mm. - Please refer the table below for the recommended mating connector, terminal and AWG wire size of **PMH-24V100WC** `☐` **T (H)** . |**Power Supply Header**|**Power Supply Header**|**Mating Connector**|**Terminal**|**AWG**| |---|---|---|---|---| |**Input (JST)**|B3P(6-2.3.5)-VH(LF)(SN)|VHR-6N|SVH-21T-P1.1|22-18| |**Output (JST)**|B4P7-VH(LF)(SN)|VHR-7N|SVH-21T-P1.1|22-18| All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (December 2018, Rev. 06)** 8 **TECHNICAL DATASHEET** **PMH Panel Mount Power Supply** 24V 100W 1 Phase / PMH-24V100WC ## Installation of Mounting Accessories - Only use M3 screw ≤ 6mm (0.23 inch) through the base mounting holes. This is to keep a safety distance between the screw and internal components. - Recommended mounting tightening torque: 4~8Kgf.cm (3.47~6.94 lbf.in). ## Safety Instructions - To ensure sufficient convection cooling, always maintain a safety distance of ≥ 20mm (0.78 inch) from all ventilated surfaces while the device is in operation. - The device is not recommended to be placed on surface with low thermal conductivity, such as plastics, for example. - Note that the enclosure of the device can become very hot depending on the ambient temperature and load of the power supply. Do not touch the device while it is in operation or immediately after power is turned OFF. Risk of burning! - Do not touch the terminals while power is being supplied. Risk of electric shock. - Prevent any foreign metal, particles or conductors from entering the device through the openings during installation. It may cause: Electric shock; Safety Hazard; Fire; Product failure - The appliance is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction. - Warning: When connecting the device, secure Earth connection before connecting L and N. When disconnecting the device, remove L and N connections before removing the Earth connection. - The device is earthed and must be inaccessible. ## **Accessories** L-02: Latch P-03: Bracket These accessories are used to mount the panel mount power supply onto a DIN rail. All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (December 2018, Rev. 06)** 9 **TECHNICAL DATASHEET** ## **PMH Panel Mount Power Supply** 24V 100W 1 Phase / PMH-24V100WC ## **Functions** - **Graph illustrating the Start-up Time, Rise Time, and Hold-up Time** ## Start-up Time The time required for the output voltage to reach 90% of its final steady state set value, after the input voltage is applied. ## Rise Time The time required for the output voltage to change from 10% to 90% of its final steady state set value. ## Hold-up Time Time between the collapse of the AC input voltage, and the output falling to 95% of its steady state set value. ## Inrush Current Inrush current is the peak, instantaneous, input current measured and, occurs when the input voltage is first applied. For AC input voltages, the maximum peak value of inrush current will occur during the first half cycle of the applied AC voltage. This peak value decreases exponentially during subsequent cycles of AC voltage. ## Dynamic Response The power supply output voltage will remains within ±5% of its steady state value, when subjected to a dynamic load from 0% to 100% of its rated current. - **50% duty cycle / 5Hz to 1KHz** All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (December 2018, Rev. 06)** 10 **TECHNICAL DATASHEET** **PMH Panel Mount Power Supply** 24V 100W 1 Phase / PMH-24V100WC ## Overload & Overcurrent Protections (Auto-Recovery) The power supply’s Overload (OLP) and Overcurrent (OCP) Protections will be activated when output current (IO) exceeds its specification as defined on Page 4 under “Protections”. In such occurrence, the output voltage (VO) will start to droop and once the power supply has reached its maximum power limit, the protection is activated and the power supply will go into “Hiccup mode” (AutoRecovery). The power supply will recover once the fault condition of the OLP and OCP is removed and IO is back within the specifications. ## Overvoltage Protection (Auto-Recovery) The power supply’s overvoltage circuit will be activated when its internal feedback circuit fails. The output voltage shall not exceed its specifications defined on Page 4 under “Protections”. ## Over Temperature Protection (Auto-Recovery) It is not recommended to prolong the duration of IO when it is less than OLP/OCP point, but greater than 100%, since it may cause damage to the PSU. As described in load de-rating section, the power supply also has Over Temperature Protection (OTP). In the event of a higher operating temperature at 100% load, the power supply will run into OTP when the operating temperature is beyond what is recommended in the de-rating graph. When activated, the output voltage will go into bouncing mode until the temperature drops to its normal operating temperature as recommended in the de-rating graph. ## Short Circuit Protection (Auto-Recovery) The power supply’s output OLP/OCP function also provides protection against short circuits. When a short circuit is applied, the output current will operate in “Hiccup mode”, as shown in the illustration in the OLP/OCP section on this page. The power supply will return to normal operation after the short circuit is removed. ## External Input Protection Device The unit is protected with internal fuse (not replaceable) at L pin and it has been tested and approved on 20A (UL) and 16A (IEC) branch circuits without additional protection device. An external protection device is only required if the supplying branch has an ampacity greater than above. Thus, if an external protective device is necessary, or, utilized, please refer a minimum value of 10A C- characteristic breaker should be used. All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (December 2018, Rev. 06)** 11 **TECHNICAL DATASHEET** ## **PMH Panel Mount Power Supply** 24V 100W 1 Phase / PMH-24V100WC ## Operating Mode ## **Redundant Operation** In order to ensure proper redundant operation for the power supply units (PSUs), the output voltage difference between the two units must be kept at 0.45~0.50V for these 24V supplies. Follow simple steps given below to set them up for the redundant operation: ## **Step 1.** Measure output voltage of PSU 1 and PSU 2. If PSU 1 is the master unit, then VO of PSU 1 must be higher than PSU 2. In order to set the output voltage, individually connect each power supply to 50% of rated load at any line voltage from 85-264Vac, and set the PSU 1 and PSU 2 output voltage. ## **Step 2.** Connect the power supply units PSU 1 and PSU 2 to Vin 1 & Vin 2, respectively, of the DRR-20N (or 20A) module shown on the right of above diagram. **The Signal GND in the DRR module is for the built-in LED and DC OK signals. The Output GND terminals from the two PSU’s do not need to be connected to the Signal GND terminal. ## **Fig. 3 Redundant Operation Connection Diagram** ## **Step 3.** Connect the system load to Vout. Please note that output voltage Vout from DRR module will be = VO (output voltage of power supply) – Vdrop* (in DRR module). *Vdrop will vary from 0.60V to 0.90V (Typical 0.65V) depending on the load current and surrounding air temperature. ## **Parallel Operation** The power supply units (PSUs) can also be used for parallel operation in order to increase the output power. The difference in output voltage between the two units must be kept to within 25mV of each other. This difference must be verified with the same output load connected independently to each unit. Parameters such as EMI, inrush current, leakage current, PARD, start up time will be different from those on the datasheet, when two units are connected in parallel. The user will need to verify that any differences will still allow the two power supplies connected in parallel will work properly in their product/application. **Fig. 4 Parallel Operation Connection Diagram** All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (December 2018, Rev. 06)** 12 **TECHNICAL DATASHEET** **PMH Panel Mount Power Supply** 24V 100W 1 Phase / PMH-24V100WC **Fig. 5 DC Input Operation Connection Diagram** ## **DC Input Operation** ## **Step 1.** Use a battery or similar DC source. ## **Step 2.** Connect +pole to L and -pole to N. ## **Step 3.** Connect the PE terminal to an earth wire or to the machine ground. **Fig. 6 2 of 3 Phase System Input Operation Connection Diagram** ## **2 of 3 Phase System Input Operation** Delta's PMH can use on 2 of 3 phase system. Please refer to the following step. ## **Step 1.** The input voltage applied from Line to Neutral is below the maximum rated input. The input voltage shall be below 240Vac +10%. ## **Step 2.** The external protector is needed on N (Neutral) input line to secure a safety. N line does not have internal fuse protection. An appropriate fuse or circuit breaker should be connected in series with N input line connection like the following. All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (December 2018, Rev. 06)** 13 **TECHNICAL DATASHEET** **PMH Panel Mount Power Supply** 24V 100W 1 Phase / PMH-24V100WC ## **Others** ## Delta RoHS Compliant ## **Restriction of the usage of hazardous substances** The European directive 2011/65/EU limits the maximum impurity level of homogeneous materials such as lead, mercury, cadmium, chrome, polybrominated flame retardants PBB and PBDE for the use in electrical and electronic equipment. RoHS is the abbreviation for “Restriction of the use of certain hazardous substances in electrical and electronic equipment”. This product conforms to this standard. ## PFC – Norm EN 61000-3-2 ## **Line Current Harmonic content** Typically, the input current waveform is not sinusoidal due to the periodical peak charging of the input capacitor. In industrial environment, complying with EN 61000-3-2 is only necessary under special conditions. Complying to this standard can have some technical drawbacks, such as lower efficiency as well as some commercial aspects such as higher purchasing costs. Frequently, the user does not profit from fulfilling this standard, therefore, it is important to know whether it is mandatory to meet this standard for a specific application. ## Attention Delta provides all information in the datasheets on an “AS IS” basis and does not offer any kind of warranty through the information for using the product. In the event of any discrepancy between the information in the catalog and datasheets, the datasheets shall prevail (please refer to www.DeltaPSU.com for the latest datasheets information). Delta shall have no liability of indemnification for any claim or action arising from any error for the provided information in the datasheets. Customer shall take its responsibility for evaluation of using the product before placing an order with Delta. Delta reserves the right to make changes to the information described in the datasheets without notice. All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (December 2018, Rev. 06)** 14
Updated at June 5, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →