Image not available
Illustrative purposes only
PMC-24V150W1AA
AC/DC Enclosed Power Supply (PSU), ITE, 1 Outputs, 150 W, 24 VDC, 6.25 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: DELTA ELECTRONICS
- Product type: AC / DC Enclosed Power Supplies
- SVHC: To Be Advised
- Product Range: PMC Series
- No. of Outputs: 1Outputs
- Output Power Max: 150W
- Input Voltage VAC: 85V AC to 264V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 6.25A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 24VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 5 |
| Price | 34.2 € |
| Current stock | 10+ |
| Lead time | 30 days |
**TECHNICAL DATASHEET** ## **PMC Panel Mount Power Supply** 24V 150W 1 Phase / PMC-24V150W1AX ## **PMC** ## **Highlights & Features** - Universal AC input range from 85Vac to 264Vac without power de-rating - Full Aluminum casing for light weight and corrosion resistant handling - High MTBF > 700,000 hrs. as per Telcordia SR-332 - Overvoltage / Overcurrent / Over Temperature Protections - • Certified according to IEC/EN/UL 62368-1 - IP 20 Compliant (for PMC-24V150W1AJ) ## **Safety Standards** CB Certified for worldwide use **Model Number:** PMC-24V150W1AX **Unit Weight** : 0.48 kg (1.06 lb) **Dimensions (L x W x H):** 178 x 97 x 38 mm (7.01 x 3.82 x 1.50 inch) ## **General Description** The new Panel Mount Power Supply is the latest offering from one of the world’s largest power supply manufacturers and solution providers - Delta. The product range offers a nominal output voltage of 24V, a wide temperature range from -10°C to +70°C and a highly dependable minimum holdup time. The state-of-the-art design is made to withstand harsh industrial environments. What makes the product stands out from the crowd is its lightweight full aluminum body design which can withstand shock and vibration according to IEC60068-2. Delta’s Panel Mount Power Supply also offers overvoltage and overload protection. Using a wide input voltage range design, it is compatible worldwide. The input also includes DC operating voltage from 125-375Vdc. Best of all, this excellent design and quality does not come with a big price tag. ## **Model Information** PMC Panel Mount Power Supply |**ModelNumber**|**Input Voltage Range**|**OutputVoltage**|**Output Current**| |---|---|---|---| |PMC-24V150W1AX|85-264Vac(125-375Vdc)|24Vdc|6.25A| ## **Model Numbering** |**Model Numbering**||||||| |---|---|---|---|---|---|---| |**PMC**|**24V**|**150W**|**1**|**A**|**X**|| |PMC Series|Output Voltage|Output Power|Single Phase|Delta Standard|A - Terminal Block|A - Terminal Block| ||||||J - IP 20 Connector|J - IP 20 Connector| **==> picture [75 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> A J<br>**----- End of picture text -----**<br> 1 All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (December 2020, Rev. 04)** **TECHNICAL DATASHEET** ## **PMC Panel Mount Power Supply** 24V 150W 1 Phase / PMC-24V150W1AX ## **Specifications** Input Ratings / Characteristics |**Specifications**<br>Input Ratings / Characteristics|| |---|---| |Nominal Input Voltage|100-240Vac| |Input Voltage Range|85-264Vac| |Nominal Input Frequency|50-60Hz| |Input Frequency Range|47-63Hz| |Nominal DC Input Voltage|125-250Vdc| |DC Input Voltage Range|125-375Vdc| |Input Current|< 3.1A@115Vac, < 2.0A@230Vac| |Efficiencyat 100% Load|> 87%@115Vac, > 88%@230Vac| |Max Inrush Current|< 60A @ 115Vac, < 120A @ 230Vac| |Power Factor|NA| |Leakage Current|< 1mA@240Vac| Output Ratings / Characteristics |Output Ratings / Characteristics|| |---|---| |Nominal Output Voltage|24Vdc| |Output Voltage Tolerance|± 2%(initial set point tolerance from factory)| |Output Voltage Adjustment Range|22-28Vdc| |Output Current|6.25A| |Output Power|150W| |Line Regulation|< 0.5% typ. (@ 85-264Vac input, 100% load)| |Load Regulation|< 1% typ.(@85-264Vac input, 0-100% load)| |PARD(20MHz)|< 100mVpp| |Rise Time|< 30ms@nominal input(100% load)| |Start-up Time|< 1000ms @ nominal input (100% load)| |Hold-upTime|> 15ms@115Vac,> 80ms@230Vac(100% load)| |Dynamic Response (Overshoot & Undershoot O/P Voltage)|± 5% @ 0-100% load| |Start-upwith Capacitive Loads|8,000µF Max| ## Mechanical |Mechanical|| |---|---| |Case Cover|Aluminium| |Dimensions (L x W x H)|178 x 97 x 38 mm (7.01 x 3.82 x 1.50 inch)| |Unit Weight|0.48 kg (1.06 lb)| |Indicator|Green LED(DC OK)| |System Cooling|Convection| |Terminal<br>Input and Output|PMC-24V150W1AA: M3.5 x 7 Pins (Rated 300V/15A)<br>PMC-24V150W1AJ: M3.5 x 7 Pins (Rated 300V/20A)| |Wire|PMC-24V150W1AA: AWG 18-14<br>PMC-24V150W1AJ: AWG 18-12| |Noise|Sound Pressure Level(SPL)<40dBA| | 2 All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (December 2020, Rev. 04)** **TECHNICAL DATASHEET** ## **PMC Panel Mount Power Supply** 24V 150W 1 Phase / PMC-24V150W1AX ## Environment |Environment||| |---|---|---| |Surrounding Air Temperature|Operating|-10°C to +70°C| ||Storage|-25°C to +85°C| |Power De-rating||> 50°C de-rate power by 2.5% / °C| |OperatingHumidity||< 95% RH| |OperatingAltitude||3,000 Meters| |Shock Test (Non-Operating)||IEC60068-2-27, 30G (300m/S²) for a duration of 18ms| |||3 times per direction, 18 times in total| |Vibration (Non-Operating)||IEC60068-2-6, 10Hz to 500Hz @ 50m/S² (5G peak);| |||20 minper axis for all X,Y,Z direction| |Pollution Degree||2| ## Protections |Protections|| |---|---| |Overvoltage|< 32V ±10%, SELV output, Hicc-up Mode,| ||Non-Latching (Auto recovery).| |Overload / Overcurrent|> 120% of rated load current, Hicc-up Mode,| ||Non-Latching (Auto recovery).| |Over Temperature|< 75°C Ambient Temp@ 100% load,| ||Non-Latching (Auto-recovery).| |Short Circuit|Hicc-up Mode, Non-Latching| ||(Auto-recoverywhen the fault is removed).| |Protection Against Shock|Class I with PE* connection| |*PE: Primary Earth|| |Reliability Data|| |MTBF|> 700,000 hrs,asper Telcordia SR-332| |Expected CapLife Time|10years(115Vac & 230Vac,50% load@40°C)| *PE: Primary Earth ## Reliability Data | All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (December 2020, Rev. 04)** 3 **TECHNICAL DATASHEET** ## **PMC Panel Mount Power Supply** 24V 150W 1 Phase / PMC-24V150W1AX ## Safety Standards / Directives |EMC|| |---|---| |EMC / Emissions|CISPR32, EN55032, FCC Title 47: Class B| |Immunityto|| |Electrostatic Discharge<br>IEC61000-4-2|Level 4 Criteria A1)<br>Air Discharge: 15kV<br>Contact Discharge: 8kV| |Radiated Field<br>IEC61000-4-3|Level 3 Criteria A1)<br>80MHz-1GHz, 10V/M with 1kHz tone / 80% modulation| |Electrical Fast Transient / Burst<br>IEC61000-4-4|Level 3 Criteria A1)<br>2kV| |Surge<br>IEC61000-4-5|Level 3 Criteria A1)<br>Common Mode2): 2kV<br>Differential Mode3): 2kV| |Conducted<br>IEC61000-4-6|Level 3 Criteria A1)<br>150kHz-80MHz, 10Vrms| |Power Frequency Magnetic Fields<br>IEC61000-4-8|Criteria A1)<br>10A/Meter| |Voltage Dips<br>IEC61000-4-11|100% dip; 1 cycle (20ms); Self Recoverable| |Low Energy Pulse Test (Ring Wave)<br>IEC61000-4-12|Level 3 Criteria A1)<br>Common Mode2): 2kV<br>Differential Mode3): 1kV| - 1) Criteria A: Normal performance within the specification limits - 2) Asymmetrical: Common mode (Line to earth) - 3) Symmetrical: Differential mode (Line to line) 4 All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (December 2020, Rev. 04)** | ## **TECHNICAL DATASHEET PMC Panel Mount Power Supply** 24V 150W 1 Phase / PMC-24V150W1AX ## **Block Diagram** ## **Device Description** **==> picture [117 x 109] intentionally omitted <==** **----- Start of picture text -----**<br> aeSEREAeRSaeeS<br>aan Seen alea<br>— ORRens TE<br>SUNN CREED<br>“RO |] GoXe™<br>S || SRN SIKA<br>NARS.MOS b<TS, ~<br>SUNLAA><br>**----- End of picture text -----**<br> - 1) Input & Output terminal block connector 2) DC Voltage adjustment potentiometer - 3) DC OK control LED (Green) 5 All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (December 2020, Rev. 04)** ## **TECHNICAL DATASHEET PMC Panel Mount Power Supply** 24V 150W 1 Phase / PMC-24V150W1AX ## **Dimensions** **L x W x H:** 178 x 97 x 38 mm (7.01 x 3.82 x 1.50 inch) ## **Engineering Data** De-rating VS surrounding air temperature ## **Note** 1. Power supply components may degrade, or be damaged, when the power supply is continuously used outside the shaded region, refer to the graph shown in Fig. 1. 2. If the output capacity is not reduced when the surrounding air temperature > 50°C, the device may run into Over Temperature Protection. When activated, the output voltage will go into bouncing mode and will recover when the surrounding air temperature is lowered or the load is reduced as far as necessary to keep the device in working condition. 3. If the device has to be mounted in any other orientation, please do not hesitate to contact **info@deltapsu.com** for more details. **Fig. 1 De-rating for Vertical and Horizontal Mounting Orientation > 50°C de-rate power by 2.5% / °C** 4. In order for the device to function in the manner intended, it is also necessary to keep a safety distance of 20mm with adjacent units while the device is in operation. 5. Depending on the surrounding air temperature and output load delivered by the power supply, the device housing can be very hot! 6 All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (December 2020, Rev. 04)** **TECHNICAL DATASHEET** ## **PMC Panel Mount Power Supply** 24V 150W 1 Phase / PMC-24V150W1AX De-rating VS AC input voltage ■ No output power de-rating across the entire input voltage range ## **Assembly & Installation** ## Mounting **Ⓐ** Mounting holes for power supply assembly onto the mounting surface. Power supply shall be mounted on minimum 2 mounting holes using M3 screw minimum 5 mm length. **Ⓑ** This surface belongs to customer’s end system or panel where the power supply is mounted. **Ⓒ** Connector. ## **Side Mounting (Vertical) Base Mounting (Vertical) Side Mounting (Horizontal)** **Fig. 2 Mounting Orientation** ## Installation - Only use M3 screw ≤ 6 mm through the base mounting holes. This is to - keep a safe distance between the screw and internal components. - Recommended mounting tightening torque : 4~8Kgf.cm 7 All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (December 2020, Rev. 04)** **TECHNICAL DATASHEET** ## **PMC Panel Mount Power Supply** 24V 150W 1 Phase / PMC-24V150W1AX ## Safety Instructions - To ensure sufficient convection cooling, always maintain a safety distance of > 20mm from all ventilated surfaces while the device is in operation. - The device is not recommended to be placed on low thermal conductive surface, for example, plastics. - Note that the enclosure of the device can become very hot depending on the ambient temperature and load of the power supply. Do not touch the device while it is in operation or immediately after power is turned OFF. Risk of burning! - Do not touch the terminals while power is being supplied. Risk of electric shock. - Prevent any foreign metal, particles or conductors to enter the device through the openings during installation. It can cause: - - Electric shock; Safety Hazard; Fire; Product failure - Warning: When connecting the device, secure Earth connection before connecting L and N. When disconnecting the device, remove L and N connections before removing the Earth connection. ## **Functions** ## ■ **Graph illustrating the Start-up Time, Rise Time, and Hold-up Time** ## Start-up Time The time required for the output voltage to reach 90% of its set value, after the input voltage is applied. ## Rise Time The time required for the output voltage to change from 10% to 90% of its set value. ## Hold-up Time Hold up time is the time when the AC input collapses and output voltage retains regulation for a certain period of time. The time required for the output to reach 95% of its set value, after the input voltage is removed. 8 All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (December 2020, Rev. 04)** **TECHNICAL DATASHEET** ## **PMC Panel Mount Power Supply** 24V 150W 1 Phase / PMC-24V150W1AX ## Inrush Current Inrush Current is the first surge current seen on the input side when AC input is applied to the power supply. It is the first pulse captured; see a typical picture for the inrush current as seen in the power supply. ## Overload & Overcurrent Protections The power supply’s Overload (OLP) and Over current (OCP) Protections will be activated when output current exceeds 120% of IO (Max load). In such occurrence, the VO will start to droop and once the power supply has reached its maximum power limit, the protection is activated and the power supply will go into “Hiccup mode” (Auto-Recovery). The power supply will recover once the fault condition of the OLP and OCP is removed and IO is back within the specifications. ## Dynamic Response The power supply output voltage will remains within ±5% of its steady state value, when subjected to a dynamic load from 5% to 100% of its rated current. - **50% duty cycle / 5Hz to 1KHz** Additionally, if the IO is < 120% but > 100% for a prolong period of time (depending on the load), the Over Temperature Protection (OTP) will be activated due to high temperature on critical components. The power supply will then go into “Hiccup mode” until power supply cool down. ## Over Temperature Protection As mentioned above, the power supply also has Over Temperature Protection (OTP). This is activated when the overload condition persists for an extended duration and the output current is below the overload trigger point but > 100% load. In the event of a higher operating condition at 100% load, the power supply will run into OTP when the surrounding air temperature is > 75°C. When activated, the output voltage will go into bouncing mode until the operating surrounding temperature drops to 50°C or output capacity is reduced as recommended in the de-rating graph. ## Short Circuit Protection The power supply’s output OLP/OCP function also provides protection against short circuits. When a short circuit is applied, the output current will operate in “Hiccup mode”, as shown in the illustration in the OLP/OCP section on this page. The power supply will return to normal operation after the short circuit is removed. ## Overvoltage Protection The power supply’s overvoltage circuit will be activated when its internal feedback circuit fails. The output voltage shall not exceed its specifications defined on Page 3 under “Protections”. 9 All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (December 2020, Rev. 04)** **TECHNICAL DATASHEET** ## **PMC Panel Mount Power Supply** 24V 150W 1 Phase / PMC-24V150W1AX ## Operating Mode ## **Redundancy Operation** In order to ensure proper redundancy operation for the power supply unit (PSU), ensure that the output voltage difference between the two units is kept at 0.45~0.50V for 24V supplies. Follow simple steps given below to verify: ## **Step 1.** Measure output voltage of PSU 1 and PSU 2. If PSU 1 is the master unit, then VO of PSU 1 must be higher than PSU 2. In order to set the output voltage, connect the power supply to 50% load and set the PSU 1 and PSU 2 output voltage. ## **Step 2.** **Fig. 3 Redundancy / Parallel Operation Connection Diagram** Connect the right DRR module, 20A as per the system requirement to the power supply units PSU 1 and PSU 2 at Vin 1 & Vin 2 respectively. ## **Step 3.** Connect the system load from Vout. Please note that output voltage Vout from DRR module will be = VO (output voltage of power supply) – Vdrop* (in DRR module). ## **Parallel Operation** These DRR modules can also be used for Parallel function in order to increase the output power by N+1 (e.g. 2.5A + 2.5A = 5A or 2.5A + 2.5A + 2.5A = 7.5A) or current sharing, and thus increasing the power supply and system reliability. Though the PMC-24V150W1AX is not designed for current sharing, a good current sharing between two power supplies can be achieved by following simple steps as below (Refer to Fig. 3 for the Connection Diagram). ## **Step 1.** Set output load condition for both supplies at 50% and measure the output voltages. ## **Step 3.** Connect PSU 1 and PSU 2 with the DRR-20A module and measure at Vin 1 & Vin 2 to verify the voltage difference. Ensure the voltages are within ±25mV. ## **Step 2.** Adjust output voltages to the same level or within ±25mV difference. ## **Step 4.** Output voltage from DRR module Vout will be = VO (output voltage of power supply) – Vdrop* (in DRR module). ## ***Vdrop will vary from 0.60V to 0.90V (Typical 0.65V) depending on the load current and surrounding air temperature.** All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (December 2020, Rev. 04)** 10 **TECHNICAL DATASHEET** ## **PMC Panel Mount Power Supply** 24V 150W 1 Phase / PMC-24V150W1AX ## **Others** ## Attention Delta provides all information in the datasheets on an “AS IS” basis and does not offer any kind of warranty through the information for using the product. In the event of any discrepancy between the information in the catalog and datasheets, the datasheets shall prevail (please refer to www.DeltaPSU.com for the latest datasheets information). Delta shall have no liability of indemnification for any claim or action arising from any error for the provided information in the datasheets. Customer shall take its responsibility for evaluation of using the product before placing an order with Delta. Delta reserves the right to make changes to the information described in the datasheets without notice. 11 All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (December 2020, Rev. 04)** |
Updated at June 5, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →