Image not available
Illustrative purposes only
PMC-12V035W1AA
AC/DC Enclosed Power Supply (PSU), ITE, 1 Outputs, 36 W, 12 VDC, 3 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: DELTA ELECTRONICS
- Product type: AC / DC Enclosed Power Supplies
- SVHC: To Be Advised
- Product Range: PMC Series
- No. of Outputs: 1Outputs
- Output Power Max: 36W
- Input Voltage VAC: 85V AC to 264V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 3A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 12VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 17.21 € |
| Current stock | 10+ |
| Lead time | 30 days |
**TECHNICAL DATASHEET** ## **PMC Panel Mount Power Supply** 12V 36W 1 Phase / PMC-12V035W1A☐ ## **PMC** ## **Highlights & Features** - Universal AC input voltage range - Power will not de-rate for the entire input voltage range - Full corrosion resistant aluminium casing - Conforms to harmonic current IEC/EN 61000-3-2, Class A - High MTBF > 700,000 hrs per Telcordia SR-332 - Safety approval according to IEC/EN/UL 60950-1, IEC/EN/UL 62368-1 and EMI to EN 55032, Class B - Also available: IP20 connector ## **Safety Standards** CB Certified for worldwide use **Model Number:** PMC-12V035W1A☐ **Unit Weight:** 0.21 kg (0.46 lb) **Dimensions (L x W x H):** 98 x 97 x 38 mm (3.86 x 3.82 x 1.50 inch) ## **General Description** Delta’s PMC series of panel mount power supply offers a nominal output voltage of 12V, a wide temperature range from -10°C to +70°C and a highly dependable minimum hold-up time. The state-of-the-art design is made to withstand harsh industrial environments. What makes the product stands out from the crowd is its lightweight full aluminum body design, which can withstand shock and vibration according to IEC 60068-2. The PMC series also offers overvoltage and overload protection. Using a wide input voltage range design, it is compatible worldwide. The input also includes DC operating voltage from 125-375Vdc. Best of all, this excellent design and quality does not come with a big price tag. ## **Model Information** PMC Panel Mount Power Supply |**ModelNumber**|**Input Voltage Range**|**Rated OutputVoltage**|**Rated Output Current**| |---|---|---|---| |PMC-12V035W1A☐|85-264Vac(125-375Vdc)|12Vdc|3.00A| ## **Model Numbering** |**PM**|**C-**|**12V**|**035W**|**1**|**A**|☐| |---|---|---|---|---|---|---| |Panel Mount|Product Type<br>C – Enclosed|Output Voltage|Output Power|Single Phase|No PFC|Connector Type<br>A – Terminal Block<br>J – IP20 Connector*| **==> picture [34 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> *Options<br>**----- End of picture text -----**<br> **==> picture [77 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> A J<br>**----- End of picture text -----**<br> All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2020, Rev. 04)** 1 **TECHNICAL DATASHEET** ## **PMC Panel Mount Power Supply** 12V 36W 1 Phase / PMC-12V035W1A☐ ## **Specifications** ## Input Ratings / Characteristics |**Specifications**<br>Input Ratings / Characteristics|| |---|---| |Nominal Input Voltage|100-240Vac| |Input Voltage Range|85-264Vac| |Nominal Input Frequency|50-60Hz| |Input FrequencyRange|47-63Hz| |Nominal DC Input Voltage|125-250Vdc| |DC Input Voltage Range|125-375Vdc| |Input Current|< 0.75A@115Vac, < 0.5A@230Vac| |Efficiency at 100% Load|> 85% @ 115Vac, > 86% @ 230Vac| |Max Inrush Current(Cold Start)|< 30A@115Vac, < 60A@230Vac| |Leakage Current|< 1mA@240Vac| Output Ratings / Characteristics |Output Ratings / Characteristics|| |---|---| |Nominal Output Voltage|12Vdc| |Output Voltage Tolerance|± 2% (initial set point tolerance from factory)| |Output Voltage Adjustment Range|11-14Vdc| |Output Current|3.00A| |Output Power|36W| |Line Regulation|< 0.5% typ.(@85-264Vac input, 100% load)| |Load Regulation|< 1% typ. (@ 85-264Vac input, 0-100% load)| |PARD(20MHz)|< 100mVpp| |Rise Time|< 30ms@nominal input(100% load)| |Start-up Time|< 2500ms@nominal input(100% load)| |Hold-upTime|> 15ms@115Vac,> 80ms@230Vac(100% load)| |Dynamic Response(Overshoot & Undershoot O/P Voltage)|± 5%@0-100% load| |Start-upwith Capacitive Loads|6,600µF Max| ## Mechanical |Mechanical||| |---|---|---| |Case Chassis / Cover||Aluminium| |Dimensions (L x W x H)||98 x 97 x 38 mm (3.86 x 3.82 x 1.50 inch)| |Unit Weight||0.21 kg (0.46 lb)| |Indicator|Green LED|DC OK| |CoolingSystem||Convection| |Terminal|PMC-12V035W1AA|M3.5 x 5 Pins (Rated 300VAC/15A)| ||PMC-12V035W1AJ|<br>M3.5 x 5 Pins (Rated 300VAC/20A)| |Wire|PMC-12V035W1AA|<br>AWG 20-14| ||PMC-12V035W1AJ|AWG 20-12| |Noise(1 Meter frompower supply)||Sound Pressure Level(SPL)<40dBA| **==> picture [101 x 32] intentionally omitted <==** All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2020, Rev. 04)** 2 **TECHNICAL DATASHEET** ## **PMC Panel Mount Power Supply** 12V 36W 1 Phase / PMC-12V035W1A☐ ## Environment |Environment|||| |---|---|---|---| |Surrounding Air Temperature||Operating|-10°C to +70°C| |||Storage|-25°C to +85°C| |Power De-rating|||> 50°C de-rate power by 2.5% / °C| |OperatingHumidity|||5 to 95% RH(Non-Condensing)| |OperatingAltitude|||0 to 3,000 Meters(9,840 ft)| |Shock Test||Non-Operating|IEC 60068-2-27, 30G (300m/S²) for a duration of 18ms<br>3 times per direction, 18 times in total| |Vibration||Non-Operating|<br>IEC 60068-2-6, 10Hz to 150Hz @ 50m/S² (5G peak);<br>90 minper axis for all X,Y,Z direction| |Pollution Degree|||2| ## Protections |Protections|| |---|---| |Overvoltage|16V +10% -5%, SELV output, Hiccup Mode,<br>Non-Latching (Auto-Recovery)| |Overload / Overcurrent|> 120% of rated load current, Hiccup Mode,<br>Non-Latching (Auto-Recovery)| |Over Temperature|< 75°C Surrounding Air Temperature @ 100% load,<br>Non-Latching (Auto-Recovery)| |Short Circuit|Hiccup Mode, Non-Latching<br>(Auto-Recoverywhen the fault is removed)| |Degree of Protection|IP20 (available for PMC-12V035W1AJonly)| |Protection Against Shock|Class I with PE* connection| *PE: Primary Earth ## Reliability Data |Reliability Data||| |---|---|---| |MTBF||> 700,000 hrs, as per Telcordia SR-332<br>I/P: 115Vac,O/P: 100% load,Ta: 25°C| |Expected CapLife Time||10years(115Vac & 230Vac,50% load@40°C)| **==> picture [101 x 32] intentionally omitted <==** All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2020, Rev. 04)** 3 **TECHNICAL DATASHEET** ## **PMC Panel Mount Power Supply** 12V 36W 1 Phase / PMC-12V035W1A☐ ## Safety Standards / Directives |Safety Standards / Directives|||| |---|---|---|---| |Electrical Safety||TUV Bauart|EN 60950-1, EN 62368-1| |||UL/cUL recognized|UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E191395),<br>UL 62368-1 and CSA C22.2 No. 62368-1(File No. E191395)| |||CB scheme|IEC 60950-1, IEC 62368-1| |CCC|||GB4943| |CE|||In conformance with EMC Directive 2014/30/EU and Low<br>Voltage Directive 2014/35/EU| |Galvanic Isolation||Input to Output|3.0 KVac| |||Input to Ground|1.5 KVac| |||Output to Ground|0.5 KVac| |EMC|||| |EMC / Emissions|||CISPR32, EN55032, FCC Title 47: Class B, GB9254| |Immunityto|||EN 55024| |Electrostatic Discharge||IEC61000-4-2|Level 4 Criteria A1)<br>Air Discharge: 15kV<br>Contact Discharge: 8kV| |Radiated Field||IEC61000-4-3|Level 2 Criteria A1)<br>80MHz-1GHz, 3V/M with 1kHz tone / 80% modulation| |Electrical Fast Transient / Burst||IEC61000-4-4|Level 3 Criteria A1)<br>2kV| |Surge||IEC61000-4-5|Level 3 Criteria A1)<br>Common Mode2): 2kV<br>Differential Mode3): 2kV| |Conducted||IEC61000-4-6|Level 2 Criteria A1)<br>150kHz-80MHz, 3Vrms| |Power Frequency Magnetic Fields||IEC61000-4-8|Criteria A1)<br>1A/Meter| |Voltage Dips||IEC61000-4-11|100% dip; 1 cycle (20ms); Self Recoverable| |Low Energy Pulse Test (Ring Wave)||IEC61000-4-12|Level 3 Criteria A1)<br>Common Mode2): 2kV<br>Differential Mode3): 1kV| |Voltage Fluctuation and Flicker|||IEC/EN 61000-3-3| - 1) Criteria A: Normal performance within the specification limits - 2) Asymmetrical: Common mode (Line to earth) - 3) Symmetrical: Differential mode (Line to line) **==> picture [101 x 32] intentionally omitted <==** All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2020, Rev. 04)** 4 **TECHNICAL DATASHEET** ## **PMC Panel Mount Power Supply** 12V 36W 1 Phase / PMC-12V035W1A☐ ## **Block Diagram** ## **Device Description** **PMC-12V035W1AA:** Terminal Block ## **PMC-12V035W1AJ:** IP20 Connector - 1) Input & Output terminal block connector 2) DC Voltage adjustment potentiometer 3) DC OK control LED (Green) All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2020, Rev. 04)** 5 **TECHNICAL DATASHEET** ## **PMC Panel Mount Power Supply** 12V 36W 1 Phase / PMC-12V035W1A☐ ## **Dimensions** - **PMC-12V035W1AA:** Terminal Block **L x W x H:** 98 x 97 x 38 mm (3.86 x 3.82 x 1.50 inch) - **PMC-12V035W1AJ:** IP20 Connector **L x W x H:** 98 x 97 x 38 mm (3.86 x 3.82 x 1.50 inch) All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2020, Rev. 04)** 6 **TECHNICAL DATASHEET** ## **PMC Panel Mount Power Supply** 12V 36W 1 Phase / PMC-12V035W1A☐ ## **Engineering Data** De-rating VS surrounding air temperature ## **Note** 1. Power supply components may degrade, or be damaged, when the power supply is continuously used outside the shaded region, refer to the graph shown in Fig. 1. 2. If the output capacity is not reduced when the surrounding air temperature > 50°C, the device may run into Over Temperature Protection. When activated, the output voltage will go into bouncing mode and will recover when the surrounding air temperature is lowered or the load is reduced as far as necessary to keep the device in working condition. 3. In order for the device to function in the manner intended, it is also necessary to keep a safety distance of 20mm with adjacent units while the device is in operation. **Fig. 1 De-rating for Vertical and Horizontal Mounting Orientation > 50°C de-rate power by 2.5% / °C** 4. Depending on the surrounding air temperature and output load delivered by the power supply, the device housing can be very hot! 5. If the device has to be mounted in any other orientation, please do not hesitate to contact **info@deltapsu.com** for more details. De-rating VS AC input voltage ■ No output power de-rating across the entire input voltage range All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2020, Rev. 04)** 7 **TECHNICAL DATASHEET** ## **PMC Panel Mount Power Supply** 12V 36W 1 Phase / PMC-12V035W1A☐ ## **Assembly & Installation** ## Mounting - **Ⓐ** Mounting holes for power supply assembly onto the mounting surface. Power supply shall be mounted on minimum 2 mounting holes using M3 screw minimum 5 mm length. - **Ⓑ** This surface belongs to customer’s end system or panel where the power supply is mounted. - **Ⓒ** Connector. **Side Mounting (Vertical) Base Mounting (Vertical) Side Mounting (Horizontal)** pa cooocooccconns A) ae © are ars **Fig. 2 Recommended Mounting Orientations** • Use flexible cable (stranded or solid) with the following sizes: ~~es~~ **PMC-12V** 035 **W1AA PMC-12V** 035 **W1AJ** AWG 20-14 AWG 20-12 - PMC-12V035W1AA / PMC-12V035W1AJ: The torque at the Connector shall not exceed 13 Kgf.cm. The insulation stripping length should not exceed 0.275” or 7mm. ## Installation of Mounting Accessories - Only use M3 screw ≤ 6 mm through the base mounting holes. This is to - keep a safe distance between the screw and internal components. - Recommended mounting tightening torque : 4~8Kgf.cm All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2020, Rev. 04)** 8 **TECHNICAL DATASHEET** ## **PMC Panel Mount Power Supply** 12V 36W 1 Phase / PMC-12V035W1A☐ ## Safety Instructions - To ensure sufficient convection cooling, always maintain a safety distance of ≥ 20mm from all ventilated surfaces while the device is in operation. - The device is not recommended to be placed on low thermal conductive surface, for example, plastics. - Note that the enclosure of the device can become very hot depending on the ambient temperature and load of the power supply. Do not touch the device while it is in operation or immediately after power is turned OFF. Risk of burning! - Do not touch the terminals while power is being supplied. Risk of electric shock. - Prevent any foreign metal, particles or conductors to enter the device through the openings during installation. It can cause: Electric shock; Safety Hazard; Fire; Product failure - Warning: When connecting the device, secure Earth connection before connecting L and N. When disconnecting the device, remove L and N connections before removing the Earth connection. ## **Accessories** ## L-01: Latch ## P-03: Bracket These accessories are used to mount the panel mount power supply onto a DIN rail. All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2020, Rev. 04)** 9 **TECHNICAL DATASHEET** ## **PMC Panel Mount Power Supply** 12V 36W 1 Phase / PMC-12V035W1A☐ ## **Functions** ## ■ **Graph illustrating the Start-up Time, Rise Time, and Hold-up Time** ## Start-up Time The time required for the output voltage to reach 90% of its set value, after the input voltage is applied. ## Rise Time The time required for the output voltage to change from 10% to 90% of its set value. ## Hold-up Time Hold up time is the time when the AC input collapses and output voltage retains regulation for a certain period of time. The time required for the output to reach 95% of its set value, after the input voltage is removed. ## Inrush Current Inrush Current is the first surge current seen on the input side when AC input is applied to the power supply. It is the first pulse captured; see a typical picture for the inrush current as seen in the power supply. ## Dynamic Response The power supply output voltage will remains within ±5% of its steady state value, when subjected to a dynamic load from 0% to 100%. All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2020, Rev. 04)** 10 **TECHNICAL DATASHEET** ## **PMC Panel Mount Power Supply** 12V 36W 1 Phase / PMC-12V035W1A☐ ## Overload & Overcurrent Protections (Auto-Recovery) The power supply’s Overload (OLP) and Over current (OCP) Protections will be activated when output current exceeds 120% of IO (Max load). In such occurrence, the VO will start to droop and once the power supply has reached its maximum power limit, the protection is activated and the power supply will go into “Hiccup mode” (Auto-Recovery). The power supply will recover once the fault condition of the OLP and OCP is removed and IO is back within the specifications. ## Overvoltage Protection (Auto-Recovery) The power supply’s overvoltage circuit will be activated when its internal feedback circuit fails. The output voltage shall not exceed its specifications defined on Page 3 under “Protections”. ## Over Temperature Protection (Auto-Recovery) It is not recommended to prolong the duration of IO when it is less than OLP/OCP point, but greater than 100%, since it may cause damage to the PSU. As described in load de-rating section, the power supply also has Over Temperature Protection (OTP). In the event of a higher operating temperature at 100% load, the power supply will run into OTP when the operating temperature is beyond what is recommended in the de-rating graph. When activated, the output voltage will go into bouncing mode until the temperature drops to its normal operating temperature as recommended in the de-rating graph. ## Short Circuit Protection (Auto-Recovery) The power supply’s output OLP/OCP function also provides protection against short circuits. When a short circuit is applied, the output current will operate in “Hiccup mode”, as shown in the illustration in the OLP/OCP section on this page. The power supply will return to normal operation after the short circuit is removed. ## **Others** ## Attention Delta provides all information in the datasheets on an “AS IS” basis and does not offer any kind of warranty through the information for using the product. In the event of any discrepancy between the information in the catalog and datasheets, the datasheets shall prevail (please refer to **www.DeltaPSU.com** for the latest datasheets information). Delta shall have no liability of indemnification for any claim or action arising from any error for the provided information in the datasheets. Customer shall take its responsibility for evaluation of using the product before placing an order with Delta. Delta reserves the right to make changes to the information described in the datasheets without notice. All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2020, Rev. 04)** 11
Updated at June 5, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →