Image not available
Illustrative purposes only
PM6760D60RPH
SOLID STATE RELAY
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SENSATA-CRYDOM / PARTNER STOCK
- Product type:
- SVHC: No SVHC (27-Jun-2024)
- Product Range: PM67 Series
| Delivery and price | |
|---|---|
| Units per pack | 3 |
| Price | 240.02 € |
| Current stock | 25+ |
| Lead time | 9 days |
## **| PM67 SERIES** ## PANEL MOUNT SOLID STATE RELAYS ## Introduction The PM67 is a compact 3-phase solid state relay in a panel mountable 67.5mm wide package with output ratings up to 75 Amps per channel @ 40°C. Its built-in overvoltage protection and the optional overtemperature protection make it suitable for demanding heating, motion and lighting applications. It’s easy to install and its large cage clamp terminals allow connecting wires up to 2 AWG size on the output terminals without the use of any additional accessories, therefore reducing installation cost and time. UL approved and VDE certified, the PM67 is a powerful and versatile solid state relay with superior performance when compared to previous generations and competitor products. ## Features - 3-Phase AC Output Panel Mount SSRs - Output ratings up to 75 Amps at 600 VAC - 2 & 3 controlled Legs option - Over Temperature protection w/alarm (optional) - Built-in overvoltage protection - Clamp Cage terminal type accepts up to 2 AWG wire size. - Layout of mounting holes compatible with standard hockey puck SSRs - IP20 touch-safe housing - AC or DC control - cURus and VDE approved ## Applications - Plastic injection molding equipment - Packaging equipment - Industrial ovens - Lighting control - Professional cooking equipment - Pump control - Conveyor drives - HVAC&R ## **PRODUCT SELECTION** |**Control Voltage**|25A|30A|50A|55A|60A|75A| |---|---|---|---|---|---|---| |**4-32 VDC**|PM6760D25P|PM6760D30P|PM6760D50P|PM6760D55P|PM6760D60P|PM6760D75P| |**90-280 VAC/VDC**|PM6760A25P|PM6760A30P|PM6760A50P|PM6760A55P|PM6760A60P|PM6760A75P| Page 1 Copyright © 2019 Sensata Technologies, Inc. www.sensata.com ## **ORDERING OPTIONS** ## Example : PM6760A25RPTA Description of part number example |**Family**||**PM67**<br>**60**<br>**x**<br>**xx**<br>**x**<br>**P**<br>**xx**|**PM67**<br>**60**<br>**x**<br>**xx**<br>**x**<br>**P**<br>**xx**|**PM67**<br>**60**<br>**x**<br>**xx**<br>**x**<br>**P**<br>**xx**|**PM67**<br>**60**<br>**x**<br>**xx**<br>**x**<br>**P**<br>**xx**|**PM67**<br>**60**<br>**x**<br>**xx**<br>**x**<br>**P**<br>**xx**|**PM67**<br>**60**<br>**x**<br>**xx**<br>**x**<br>**P**<br>**xx**|**xx**|**xx**|| |---|---|---|---|---|---|---|---|---|---|---| |||||||||||| |||||||||||| |**Operating Volta**|**ge**|||||||||| |60 = 48-600 VAC||||||||||| |**Control Voltage**||||||||||| |||||||||||| |D = 4-32 VDC (4-28 VD<br>A = 90-280 VAC/VDC|C for TA option)|||||||||| |**Rated Load Curr**|**ent**|||||||||| |25 = 25A, 3-legs<br>30 = 30A, 2-legs<br>50 = 50A, 3-legs|55 = 55A, 2-legs<br>60 = 60A, 3-legs<br>75 = 75A, 2-legs|||||||||| |**Switching Type**||||||||||| |Blank = Zero voltage tu<br>R = Instantaneous turn|rn on<br>on|||||||||| |**Overvoltage Pro**|**tection**|||||||||| |P = With internal overv|oltage protection|||||||||| |**Over Temperature Protection(1)**<br>|**Pi(1)**|||||||||| |||||||||||| |Blank = No Over Temperature protection<br>TA = With Over Temperature Protection and Alarm Output<br>Required for valid part number<br>For options only and not required for valid part||||||||||| |number||||||||||| ## **SPECIFICATIONS** ## Output[(2)] **==> picture [541 x 273] intentionally omitted <==** **----- Start of picture text -----**<br> Description 25A 30A 50A 55A 60A 75A<br>Operating Voltage (47-440Hz) [VRMS] 48-600 48-600 48-600 48-600 48-600 48-600<br>Transient Overvoltage [Vpk] [(3)] 1200 1200 1200 1200 1200 1200<br>Maximum Off-State Leakage Current @ Rated Voltage 1 1 1 1 1 1<br>[mARMS]<br>Minimum Off-State dV/dt @ Maximum Rated Voltage [V/ 500 500 500 500 500 500<br>μsec]<br>Load Current, General Use UL508/LC A IEC62314 @ 40°C 25 30 50 55 60 75<br>[ARMS]<br>Load Current, Motor Starting UL508 FLA/LC B IEC62314 @ 6.4/3.9 6.4/3.9 12/6.8 12/6.8 21/17.6 21/17.6<br>40°C [ARMS]<br>Minimum Load Current [mARMS] 100 100 100 100 150 150<br>Maximum 1 Cycle Surge Current (50/60Hz) [Apk] 286/300 286/300 716/750 716/750 1290/1350 1290/1350<br>Maximum On-State Voltage Drop @ Rated Current [VRMS] 1.25 1.3 1.25 1.3 1.15 1.20<br>Maximum 1/2 Cycle I² t for Fusing (50/60Hz) [A² sec] 409/375 409/375 2563/2343 2563/2343 8320/7593 8320/7593<br>Minimum Power Factor (at Maximum Load) 0.5 0.5 0.5 0.5 0.5 0.5<br>Motor Rating UL 508: 120 VAC / 240 VAC / 480 VAC [HP] 0.5/1.0/3.0 0.75/1.0/3.0 1.5/3.0/7.5 1.5/3.0/7.5 3.0/5.0/15.0 3.0/5.0/15.0<br>Motor Rating IEC62314: 240 VAC / 400 VAC / 500 VAC [kW] 0.75/1.5/2.2 0.75/1.5/2.2 1.5/3.0/4.0 1.5/3.0/4.0 4.0/7.5/11.0 4.0/7.5/11.0<br>**----- End of picture text -----**<br> Page 2 Copyright © 2019 Sensata Technologies, Inc. www.sensata.com ## Input[(2)] **==> picture [541 x 176] intentionally omitted <==** **----- Start of picture text -----**<br> Description PM6760Dxxx PM6760Axxx<br>wo-TA Option w-TA Option wo-TA Option w-TA Option<br>Control Voltage Range 4-32 VDC [(4)] 4-28 VDC [(4)] 90-280 VAC/VDC<br>Maximum Reverse Voltage -32 VDC -<br>Minimum Turn-On Voltage 4 VDC 90 VAC/VDC<br>Must Turn-Off Voltage 1 VDC 5 VAC/VDC<br>Minimum Input Current (for on-state) 25 mA 20 mA 1 mA 1 mA<br>Maximum Input Current 40 mA 50 mA 4 mA 8 mA<br>Nominal Input Impedance Current Limited Switching mode<br>Maximum Turn-On Time [msec] 1/2 Cycle [(5)] 10<br>Maximum Turn-Off Time [msec] 1/2 Cycle 20<br>**----- End of picture text -----**<br> ## Alarm[(2)] **==> picture [541 x 396] intentionally omitted <==** **----- Start of picture text -----**<br> Description PM6760Dxxx PM6760Axxx<br>Output type Solid State Solid State<br>Maximum Output Voltage 60 VDC 400 VDC / 265 VAC<br>Maximum Alarm Output Current [mA] 60 60<br>General [(2)]<br>Description Parameters<br>Dielectric Strength, Input to Output (50/60Hz) 4k VRMS<br>Dielectric Strength, Input/Output to Case (50/60Hz) 4k VRMS<br>Minimum Insulation Resistance (@ 500 VDC) 10 [9 ] Ohms<br>Maximum Capacitance, Input/Output 25 pF<br>Ambient Operating Temperature Range -40 to 80 °C<br>Ambient Storage Temperature Range -40 to 100 °C<br>Short Circuit Current Rating [(6) ] 100 kA<br>Weight (typical) 6.7 oz (190 g)<br>Housing Material UL94 V-0<br>Heat Sink Material Aluminum<br>DIN Rail Clip Material Zinc Plated Steel<br>Hardware Finish Nickel Plating<br>Input Terminal Screw Torque Range (lb-in/Nm) 5/0.5<br>Load Terminal Screw Torque Range (lb-in/Nm) 18-20/2.0-2.2<br>Humidity per IEC 60068-2-78 [(7)] 93%<br>LED Input Status Indicator See status chart<br>Overvoltage Category III<br>Impulse Withstand Voltage According to IEC 60664-1 6kV<br>**----- End of picture text -----**<br> Page 3 Copyright © 2019 Sensata Technologies, Inc. www.sensata.com **EQUIVALENT CIRCUIT BLOCK DIAGRAMS/WIRING DIAGRAMS** ## **PM6760XXX** **==> picture [527 x 649] intentionally omitted <==** **----- Start of picture text -----**<br> 48-600 VAC, 47-440 Hz<br>L1 L1<br>L2 L2<br>L3 L3<br> Short circuit and overload<br>current protection<br>/ > / > / ><br>1/L1 3/L2 5/L3<br>L1 L2 L3<br>T1 T2 T3<br>INPUT CONTROL<br>INPUT<br>2/T1 4/T2 6/T3<br>Motor Controller T1 T2 T3 General Use<br>Application Application<br>T1 T2 T3 T1 T2 T3<br>M<br>3<br>PM6760X(30,55,75) PM6760X(25,50,60)<br>( 2 CONTROLLED LEGS ) ( 3 CONTROLLED LEGS )<br>MAIN CIRCUIT MAIN CIRCUIT<br>L1 L2 L3 +A1 L1 L2 L3 +A1<br>T1 T2 T3 -A2 T1 T2 T3 -A2<br>48-600VAC<br>INPUT CTRL 4-32VDC<br>A1+ A2-<br>**----- End of picture text -----**<br> Page 4 Copyright © 2019 Sensata Technologies, Inc. www.sensata.com **PM6760XXXTA** **==> picture [524 x 643] intentionally omitted <==** **----- Start of picture text -----**<br> 48-600 VAC, 47-440 Hz<br>L1 L1<br>L2 L2<br>L3 L3<br> Short circuit and overload<br>current protection<br>/ > / > / ><br>1/L1 3/L2 5/L3<br>L1 L2 L3<br>T1 T2 T3<br>ALARM INPUT<br>OUTPUT A1 A2 A3 A4 CONTROL<br>INPUT<br>2/T1 4/T2 6/T3<br>Motor Controller T1 T2 T3 General Use<br>Application Application<br>T1 T2 T3 T1 T2 T3<br>M<br>3<br>PM6760X(30,55,75)TA PM6760X(25,50,60)TA<br>( 2 CONTROLLED LEGS ) ( 3 CONTROLLED LEGS )<br>MAIN CIRCUIT ALARM MAIN CIRCUIT ALARM<br>OUTPUT OUTPUT<br>L1 L2 L3 +A1 A3 L1 L2 L3 +A1 A3<br>T1 T2 T3 -A2 A4 T1 T2 T3 -A2 A4<br>48-600VAC<br>INPUT CTRL 4-32VDC<br>A1+ A2-<br>**----- End of picture text -----**<br> Page 5 Copyright © 2019 Sensata Technologies, Inc. www.sensata.com ## **MECHANICAL SPECIFICATIONS** Tolerances: ±0.02 in / 0.5 mm All dimensions are in inches [mm] **==> picture [388 x 656] intentionally omitted <==** **----- Start of picture text -----**<br> 2.66<br>67.5<br>4X . 87<br>22.2<br>1/L1 3/L2 5/L3<br>L1 L2 L3<br>T1 T2 T3 INPUT 1.88 2.93 3.61<br>47.8 74.5 91.8<br>2/T1 4/T2 6/T3<br>2X Ø .18<br>4.5<br>MOUNTING HOLE<br>2.16<br>54.7<br>1.46<br>37.2<br>48-600VAC<br>INPUT CTRL 4-32VDC<br>A1+ A2-<br>**----- End of picture text -----**<br> Page 6 Copyright © 2019 Sensata Technologies, Inc. www.sensata.com ## **SURGE CURRENT INFORMATION[(8)]** **==> picture [54 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> 25A & 30A<br>**----- End of picture text -----**<br> ## 50A & 55A ## 60A & 75A ## **THERMAL DERATE INFORMATION** ## PM6760x25 **==> picture [251 x 139] intentionally omitted <==** **----- Start of picture text -----**<br> 35<br>30<br>25 a aee ee ee<br>20 ——<br>15<br>aa FE<br>10 rr i,<br>5 a ee<br>ee ee<br>0<br>25 40 80<br>Ambient Temperature (ºC)<br>Load Current (Amps)<br>**----- End of picture text -----**<br> ## PM6760x30 **==> picture [257 x 146] intentionally omitted <==** **----- Start of picture text -----**<br> 35<br>30<br>25 i [eee] _——...—<br>“<br>20<br>15 Pep ertesseeeepe NO<br>10 rr a<br>a a<br>5<br>es ee<br>0<br>25 40 80<br>Ambient Temperature (ºC)<br>Load Current (Amps)<br>**----- End of picture text -----**<br> Page 7 Copyright © 2019 Sensata Technologies, Inc. www.sensata.com **==> picture [8 x 85] intentionally omitted <==** **----- Start of picture text -----**<br> Load Current (Amps)<br>**----- End of picture text -----**<br> **==> picture [137 x 22] intentionally omitted <==** **----- Start of picture text -----**<br> PM6760x50<br>0.25 C/W 0.5 C/W 1.0 C/W<br>**----- End of picture text -----**<br> **==> picture [239 x 140] intentionally omitted <==** **----- Start of picture text -----**<br> 70<br>60<br>50<br>40<br>30<br>20<br>10<br>0<br>25 40 80<br>Ambient Temperature (ºC)<br>**----- End of picture text -----**<br> **==> picture [259 x 168] intentionally omitted <==** **----- Start of picture text -----**<br> PM6760x55<br>0.25 C/W 0.5 C/W 1.0 C/W<br>70<br>60<br>50<br>40<br>30<br>20<br>10<br>0<br>25 40 80<br>Ambient Temperature (ºC)<br>Load Current (Amps)<br>**----- End of picture text -----**<br> **==> picture [8 x 85] intentionally omitted <==** **----- Start of picture text -----**<br> Load Current (Amps)<br>**----- End of picture text -----**<br> **==> picture [59 x 10] intentionally omitted <==** **----- Start of picture text -----**<br> PM6760x60<br>**----- End of picture text -----**<br> **==> picture [238 x 152] intentionally omitted <==** **----- Start of picture text -----**<br> 0.25 C/W 0.5 C/W 1.0 C/W DR67<br>80<br>70<br>60<br>50<br>40<br>30<br>20<br>10<br>0<br>25 40 80<br>Ambient Temperature (ºC)<br>**----- End of picture text -----**<br> **==> picture [9 x 85] intentionally omitted <==** **----- Start of picture text -----**<br> Load Current (Amps)<br>**----- End of picture text -----**<br> **==> picture [243 x 171] intentionally omitted <==** **----- Start of picture text -----**<br> PM6760x75<br>0.25 C/W 0.5 C/W 1.0 C/W DR67<br>90<br>80<br>70<br>60<br>50<br>40<br>30<br>20<br>10<br>0<br>25 40 80<br>Ambient Temperature (ºC)<br>**----- End of picture text -----**<br> ## **STATUS CHART** ## **(only for models with overtemperature protection)** **==> picture [388 x 152] intentionally omitted <==** **----- Start of picture text -----**<br> TA SUFFIX MODELS<br>**----- End of picture text -----**<br> **==> picture [153 x 12] intentionally omitted <==** **----- Start of picture text -----**<br> Conditions Description<br>**----- End of picture text -----**<br> |1,11|Initial Condition.| |---|---| |2, 4|Control Input is On, Output is activated,<br>temperature rises,Green LED is On.| |3,7|Control Input is Off,Output is Off.| |5|LED changes to solid Orange color.| ||Output is Off due to overtemperature,| |6, 9|Alarm is latched On, LED changes to| ||solid red.| ||While Control Input is Off: Output,| |7|Alarm and LED remains Off. (Control| ||Input Min. 100ms Off to reset values)| |8|Control Input is On, Output is on and<br>temperature rises.| |6, 10|Alarm will reset until Control Input<br>is Off.| |6|, 1|<br>is Off.|<br>is Off.|<br>is Off.|<br>is Off.|<br>is Off.| |---|---|---|---|---|---|---| |* Max.|60|ms OFF when applying PWM on Control Input.||||| ||||||Green|Output On| ||||LED<br>Color||Red|Alarm| ||||||Yellow|Pre-Alarm| Page 8 Copyright © 2019 Sensata Technologies, Inc. www.sensata.com ## **INSTALLATION INSTRUCTIONS** ## **Mounting on Heat Sink** **==> picture [114 x 148] intentionally omitted <==** - Select adequate heat sink (see thermal derating curves in product series datasheet). - Be sure to use a thermal pad (part no. HSP-8) or equivalent thermal compound between the SSR and the selected heat sink. - SSR housing mounting holes have a diameter of 0.341in (8.66mm). Two screws are needed to mount the SSR onto a heat sink (See fig.1). Mounting screws are sold separately as HK8. Otherwise, recommended screw size is 8-32 (socket) using an allen wrench (9/64 in) for the installation. Choose screw length considering mounting surface hole depth and SSR baseplate thickness of 0.125 in (3.2 mm). - Before applying full torque tighten down both screws until they contact the baseplate.Then, tighten them to 20 lb-in (2.2 Nm) min. - For optimal thermal performance heat sink fins should be oriented vertically to promote natural convection airflow ## **Mounting on Panel** **fig.1** SSR mounted on HS053 heat sink - Locate the panel section on which the SSR will be mounted. Panel mount surface must provide adequate heat sinking capability, uncoated, clean, flat (0.004 in/in recommended) and preferably aluminum. - Be sure to use thermal pad HSP-8 or equivalent thermal compound between the SSR and the panel. - SSR housing mounting slots have a diameter of 0.341 in (8.66 mm). Two screws are needed (not included) to mount the SSR onto a panel. Mounting screws are sold separately as HK8. Otherwise, recommended screw size is 8-32 (socket) using allen wrench (9/64 in) for the installation. Choose screw length considering the mounting surface and that the SSR baseplate thickness is 0.125 in (3.2 mm). - Before applying full torque tighten down both screws until they contact the baseplate. Then, tighten them to 20 lb-in (2.2 Nm) min ## **Wiring Instructions** - Recommended wire sizes as shown in TABLE 1 - Maximum terminal screw torque input terminal 5 lb-in (0.5 Nm) (screw terminal only) - Maximum terminal screw torque load terminal 18-20 lb-in (2.0-2.2 Nm) - Strip lenght for input terminals: Per manufacturer specifications - Strip lenght for load terminals: 10mm min. - Use only copper conductors rated for 75°C **Table 1. Wire Size & Pull Out Strength** |**Table 1. Wire Size & Pull Out Strength**|**Table 1. Wire Size & Pull Out Strength**|**Table 1. Wire Size & Pull Out Strength**|**Table 1. Wire Size & Pull Out Strength**| |---|---|---|---| |Terminal Confguration||Recommended Wire Size (Solid/Stranded)|Wire Pull-Out Strength (lb)[N]*| ||Output|1 x 18 AWG (1 mm2) [minimum]|20 [88]| |||1 x 8 AWG (10 mm2)|75 [333]| |||2 x 8 AWG (10 mm2)|65 [289]| |||1 x 3 AWG (26.67 mm2)(1)|90 [400]| |Input|Screw|30 AWG (0.05 mm2) [minimum]|4.5 [20]| |||12 AWG (3.3 mm2) [maximum]|30 [133]| ||Spring(2)|26 AWG (0.13 mm2) [minimum]|5 [22]| |||12 AWG (3.3 mm2) [maximum]|5 [22]| *Tests performed on Stranded wire - (1) Maximum wire size 1 x 2 AWG (35mm2) - (2) Applicable when using CP202 connector instead of supplied connector Page 9 Copyright © 2019 Sensata Technologies, Inc. www.sensata.com **==> picture [443 x 202] intentionally omitted <==** **----- Start of picture text -----**<br> ACCESSORIES<br>®<br>Recommended Accessories<br>Be<br>Heat Sink Thermal<br>Hardware Kit Thermal Pad Connectors ID Marker<br>Part No. Resistance [°C/W]<br>a HS073 ee 0.7<br>CNLB<br>HS053 0.5 CP201<br>HK8 HSP-8 CNLN<br>HS033 0.36 CP202<br>CNL2<br>HS023 0.25<br>Ptft tt<br>**----- End of picture text -----**<br> ## **AGENCY APPROVALS & CERTIFICATIONS** **Approvals (Tested and Certified According To)** E116949 40047491 UL 508 and C22.2 No. 14 EN 62314 ~~en~~ **CONFORMANCES ENVIRONMENTAL** ~~ee~~ **Vibration Resistances to and Shock heat and fire Resistance** ~~Ee~~ IEC 61373: CateIEC 60335-1, Directive Directive GBT 26572-2011 gory 1, Class B Section 30 2006/95/EC 2011/65/EU ~~pf tT~~ Page 10 Copyright © 2019 Sensata Technologies, Inc. www.sensata.com |**Electromagnetic Compatibility**<br>~~Rn~~<br>~~esa~~|**Electromagnetic Compatibility**<br>~~Rn~~<br>~~esa~~|**Electromagnetic Compatibility**<br>~~Rn~~<br>~~esa~~|**Electromagnetic Compatibility**<br>~~Rn~~<br>~~esa~~|**Electromagnetic Compatibility**<br>~~Rn~~<br>~~esa~~| |---|---|---|---|---| |**Generic Standard**<br>~~es~~|**Immunity Tests**<br>|**Test Specification Level**<br>~~a~~||**Performance**<br>~~a~~| |IEC 61000-6-2<br>Immunity for Industrial Envi-<br>ronments"<br>~~es ~~<br>=<br>“|Electrostatic Discharge<br>IEC 61000-4-2<br> <br>~~_———————eEEe~~|8kV air discharge<br> ~~a~~||Criterion A<br>~~a~~| |||6kV contact discharge<br>~~Pf~~<br>~~_———————eEEe~~||Criterion A<br>~~Pf~~<br>~~_———————eEEe~~| ||Fast transient (burst)<br>IEC 61000-4-4<br>~~_———————eEEe~~<br>~~|~~|Output<br>~~_———————eEEe~~|2kV, 5kHz, 100kHz<br>~~_———————eEEe~~|Criterion B<br>~~_———————eEEe~~| |||Input<br>~~_———————eEEe~~<br>~~|[EE~~|1kV, 5kHz, 100kHz<br>~~_———————eEEe~~<br>~~[EE~~|Criterion B<br>~~_———————eEEe~~<br>~~a~~<br>~~TE~~| ||Surge<br>IEC 61000-4-5<br>~~_———————eEEe~~<br>~~|~~|Output<br>~~_———————eEEe~~<br>~~|[EE~~|1kV Line to Line<br>~~_———————eEEe~~<br>~~[EE~~|Criterion B<br>~~_———————eEEe~~<br>~~a~~<br>~~TE~~| ||||2kV Line to Earth<br>~~[EE~~|Criterion B<br>~~a~~<br>~~TE~~| |||AC Input Option<br>~~| [EE~~|1kV Line to Line<br>~~[EE~~<br>~~ee~~|Criterion A<br>~~a~~<br>~~TE~~<br>~~ee~~| ||||2kV Line to Earth<br>~~ee~~|Criterion A<br>~~ee~~| ## **GENERAL NOTES** (1) Option available upon demand. Please contact your local Sensata representative for additional information. (2) All parameters at 25°C unless otherwise specified per Channel. (3) Output will self trigger between 900-1200 Vpk, not suitable for capacitive loads. (4) Increase minimum voltage by 1 V for operations from -20 to -40°C. (5) Turn-on time for Instantaneous turn-on versions is 0.1 msec. (6) When protected with the appropriate class and rated fuse. For detailed info please contact Sensata Technical Support. (7) No freezing or condensation allowed. (8) For single surge pulse Tc=25°C; Tj=125°C. For AC Output SSRs, AC RMS value of surge current equals the peak value divided by 2 (1.414). ## **WARNINGS** RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE - The product’s side panels may be hot, allow the product to cool before touching - Follow proper mounting instructions including torque values - Do not allow liquids or foreign objects to enter this product **Failure to follow these instructions can result in serious injury, or equipment damage.** ## HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH - Disconnect all power before installing or working with this equipment - Verify all connections and replace all covers before turning on power **Failure to follow these instructions will result in death or serious injury.** Page 11 Sensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, evaluation and judgment in designing Buyer’s systems and products. Sensata data sheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements, improvements and other changes to its data sheets or components without notice. Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE OF THE DATA SHEETS, EXPRESS, IMPLIED OR STATUTORY, INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATA SHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. ## **CONTACT US** ## **Americas** +1 (877) 502 5500 – Option 2 sales.crydom@sensata.com **Europe, Middle East & Africa** +44 (1202) 416170 ssr-info.eu@sensata.com **Asia Pacific** sales.isasia@list.sensata.com China +86 (21) 2306 1500 Japan +81 (45) 277 7117 Korea +82 (31) 601 2004 India +91 (80) 67920890 Rest of Asia +886 (2) 27602006 ext 2808 Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA. www.sensata.com Rev:08/09/19 ERN 20741 FDE-07-01 Rev.B Copyright © 2019 Sensata Technologies, Inc.
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →