Image not available
Illustrative purposes only
PM-0112-070-0.
POWER SUPPLY, AC-DC, 12V, 7A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: BLOCK
- Product type:
- Power Supply Applications:ITE; No. of Outputs:1 Output; Output Power Max:84W; Output Voltage - Output 1:12VDC; Output Current - Output 1:7A; Output Voltage - Output 2:-; 53Y0122
- SVHC: No SVHC (21-Jan-2025)
- Product Range: -
- No. of Outputs: 1 Output
- Output Power Max: 84W
- Current, Output 4: -
- Input Voltage VAC: 100V AC to 240V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 7A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 12VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 129.92 € |
| Current stock | 10+ |
| Lead time | 30 days |
Single-phase, primary switched mode power supply **PM-0112-070-0** ~~DT~~ ## Advantages Stabilized and adjustable output voltage Low stand-by consumption <1 W Constant current limiting without overload shutdown DC OK indicator Push-in terminals Robust DIN rail mounting In compliance with EN 60335-1 3 years warranty ## Applications Efficient, primary switched mode power supply in slim plastic housing. A powerful and flexible option that's still light and compact. Our real all-rounders, these power supply units are suitable for a highly diverse range of applications in solar, measurement and control technology as well as industrial and building automation. The devices cover the lower and average power requirements from 25 W to 100 W. Versions with 12 V, 24 V, 30.5 V and 48 V are available, enabling a whole range of applications. A version with 3.8 A rated current is available for establishing NEC Class 2 circuits. All power supplies also comply with the EN 60335-1 standard for domestic appliances. The output voltage can be easily set using the rotary potentiometer on the front of the housing. The DIN rail fastening method and push-in connection terminals enable fast and secure mounting. Versions for construction of AS-i circuits as well as for medical applications according to UL 60601 are available. **==> picture [102 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> Picture shows PM-0124-040-0<br>**----- End of picture text -----**<br> ## Standards Z ## Approvals # W o Z Primary switched mode power supply to UL 60950, UL 508 UL/CSA 60950 recognised, UL508 listed, Germanischer Lloyd Safety: EN 61558-2-16, EN 60950-1, EN 60335-1 EMC: EN 61204-3 ## Single-phase, primary switched mode power supply **PM-0112-070-0** |||Type|PM-0112-070-0| |---|---|---|---| |+-||Special features<br>Characteristics|-| |o <br>b<br>oO<br>xe)<br>=|Input<br>Input rated voltage<br>Input voltage range<br>Input voltage derating<br> ~~| ——~~||100 - 240 Vac<br>85 - 264 Vac (120 - 372 Vdc)<br>-2,5 %/Vac < 95 Vac| |9||Rated frequency range|44 Hz - 66 Hz / 0 Hz| |oO<br>wo||Input rated current (rated load)<br>Starting current limiter<br>Switch-on time|1.87 A (100 Vac) / 0.94 A (240 Vac)<br>< 30 A, NTC<br>0.5 s (100 Vac) / 0.3 s (230 Vac)| |||Power factor<br>Input fuse internal|0.55<br>4 A| |||Recommended back-up fuse (circuit breaker)<br>Mains buffering (rated load)<br>Transient surge voltage protection<br>Output|6 A, 10 A, 16 A,<br>characteristic B, C<br>15 ms (100 Vac) / 80 ms (230 Vac)<br>varistor| |||Output rated voltage<br>Output voltage range<br>Output rated current<br>Output limited current|12 Vdc<br>11,5 – 14,5 Vdc<br>7 A<br>7.7 ... 8 A (constant current)| |||Class 2 output (UL Limited Power Source, LPS)|No| |||Parallel connection|Yes| |||Serial operation|Yes| |||Power dissipation, no load/rated load|<1 W / 16.2 W (230 Vac)| |||Max. power losses|19.8 W (100 Vac / 12 V / 7 A)| |||Ripple factor|typ. 20mVss| |||Resistance to reverse feed max.|25 Vdc| |||Over-voltage-protection|max. 32 Vdc| |||Efficiency|86 %| |||Signaling|| ||||LED green| |||Status indicator|Uout > typ. 10 Vdc| ||||LED lit permanently| ||||Active high signal| |||Signal output|Uout > typ. 10 Vdc<br>max. 40 mA@12 Vdc| ||||short circuit proof| |||Approvals|| |||Approvals|cURus, cULus, GL| |||Environment|| |||Storage temperature|-13 °F to +185 °F| |||Ambient temperature|-13 °F to +158 °F| |||Derating|-3 %/K > +122 °F| |||Mounting position|horizontal for standard rail DIN TS35| |||Type of cooling|Natural convection| |||Required minimum spacing (left/right)|0.00 inch| |||Required minimum spacing (over/under)|1.97 inch| |||Safetyandprotection|| |||Protection index|IP 20| |||Safety class|II, without PE connection| |||Order numbers|| |||**Order Number**|**PM-0112-070-0**| **==> picture [256 x 217] intentionally omitted <==** **----- Start of picture text -----**<br> Type PM-0112-070-0<br>Terminal and mounting<br>Terminals input (direct plug-in technology Push-in) max 2,5 mm²<br>Terminals output (direct plug-in technology Push-in) max 2,5 mm²<br>boO Terminals signalling (direct plug-in technology Push- max 2,5 mm²<br>oO in)<br>xe)<br>G Measures and wei ————SSSSSSSSS_______—8QqR ghts<br>2 Weight 0.88 lbs<br>Dimensions in inch<br>5oOo<br>=<br>0.14<br>_ ——— EQD QLe_<br>3.54 1 tsi ESS |<br>s o n] = SS Ss<br>I # 0 I) | Se .<br>= is p ~<br>0.12 1.77 ———Be i ; r 6| aT ale Go<br>2.05 | ad 4.07<br>4.37<br>30<br>**----- End of picture text -----**<br>
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →