- Manufacturer: DELTA ELECTRONICS
- Product type: AC / DC Open Frame Power Supplies
- SVHC: To Be Advised
- Product Range: PJT Series
- No. of Outputs: 1 Output
- Input Voltage VAC: 90V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 3.33A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 12VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
- Power Rating (Forced Cooling): -
- Power Rating (Convection Cooling): 40W
| Delivery and price | |
|---|---|
| Units per pack | 250 |
| Price | 12.89 € |
| Current stock | 100+ |
| Lead time | 30 days |
**TECHNICAL DATASHEET** ## **PJT Open Frame Power Supply** PJT-40W Series / PJT-□□V40WBA□ ## **PJT** ## **Highlights & Features** - Universal AC input voltage - Standard industrial foot print of 2” x 3” - Low leakage current < 0.1mA - Convection cooled operating temperature range from -10°C to +70°C - High MTBF > 700,000 hrs as per Telcordia SR-332 - Multiple connector source options ## **Safety Standards** CB Certified for worldwide use **Model Number:** PJT-☐☐V40WBA☐ **Unit Weight:** 0.08 kg (0.18 lb) **Dimensions (L x W x D):** 76.2 x 50.8 x 22.9 mm [2” x 3”] ## **General Description** The PJT open frame power supply series offers choices of 12V, 15V, 18V and 24V nominal output voltages. The single output products are designed with small standard industrial foot prints at 2” x 3”. The highly efficient convection cooling designs enable optimum thermal management for high power efficiency. The PJT series of products can operate from -10°C to +70°C across the entire input voltage range of 90 to 264Vac and are certified for safety standard according to IEC/EN/UL 62368-1 and for EMI standard according to EN 55032, Class B. ## **Model Information** PJT Open Frame Power Supply |Model Number|Input Voltage Range|Rated OutputVoltage|Rated Output Current| |---|---|---|---| |PJT-12V40WBA☐|90-264Vac|12Vdc|3.33A| |PJT-15V40WBA☐||15Vdc|2.67A| |PJT-18V40WBA☐||18Vdc|2.22A| |PJT-24V40WBA☐||24Vdc|1.66A| ## **Model Numbering** |**PJ**|**T –**|**XXV**|**40W**|**B**|**A**|□| |---|---|---|---|---|---|---| |Open Frame|Product Type<br>T – ITE Application<br>Series|T – ITE Application<br>Output Voltage<br>12V<br>15V<br>18V<br>24V|Output Power|Package Type<br>B – Open Frame|Family Code<br>A|Harness Connector<br>A – JST connector<br>B – Molex connector*<br>C – JWT connector*| *Options All parameters are specified at 25°C ambient and AC unless otherwise indicated. **www.DeltaPSU.com (September 2020, Rev. 03)** 1 **TECHNICAL DATASHEET** **PJT Open Frame Power Supply** PJT-40W Series / PJT-□□V40WBA□ ## **Specifications** **Model Number** PJT-12V40WBA☐ PJT-15V40WBA☐ PJT-18V40WBA☐ PJT-24V40WBA☐ ## Input Ratings / Characteristics |Input Ratings / Characteristics|Input Ratings / Characteristics||||| |---|---|---|---|---|---| |Nominal Input Voltage||100-240Vac|||| |Input Voltage Range||90-264Vac|||| |Nominal Input Frequency||50-60Hz|||| |Input FrequencyRange||47-63Hz|||| |Input Current||< 0.85A typ. @ 115Vac|||| |Efficiency at 100% Load|115Vac|85.0% typ.|86.0% typ.|86.0% typ.|86.0% typ.| ||230Vac|86.0% typ.|87.0% typ.||87.0% typ.| |Max Inrush Current(Cold Start)||30A typ.@115Vac, 60A typ.@230Vac|||| |Leakage Current||0.1mA@240Vac|||| ## Output Ratings / Characteristics |Leakage Current<br>Output Ratings / Characteristics|Leakage Current<br>Output Ratings / Characteristics|0.1mA@240Vac|||| |---|---|---|---|---|---| |Nominal Output Voltage||12Vdc|15Vdc|18Vdc|24Vdc| |FactorySet Point Tolerance||No potentiometer(± 5%)|||| |Output Current||3.33A|2.67A|2.22A|1.66A| |Output Power||40W|||| |Line Regulation||± 0.5%@115Vac & 230Vac|||| |Load Regulation||± 1.0% @ 115Vac & 230Vac|||| |PARD* (20MHz)||< 120mVpp|< 150mVpp|< 180mVpp|< 240mVpp| |Start-up Time|115Vac|2800ms typ.(100% load)|||| ||230Vac|1100ms typ.(100% load)|||| |Hold-up Time|115Vac|18ms typ.(100% load)|||| ||230Vac|90ms typ.(100% load)|||| |Dynamic Response<br>(Overshoot & Undershoot O/P Voltage)||± 5% @ 50-100% load<br>(Slew Rate: 0.1A/µS)|||| |Start-upwith Capacitive Loads||4,000uF Max|3,500uF Max|3,000uF Max|2,000uF Max| *PARD is measured with an AC coupling mode, 5cm wires, and in parallel with 0.1μF ceramic capacitor & 47μF electrolytic capacitor. ## Mechanical |Mechanical|Mechanical|| |---|---|---| |Dimensions||76.2 x 50.8 x 22.9 mm[2” x 3”]| |Unit Weight||0.08 kg (0.18 lb)| |CoolingSystem||Convection| |Power Supply Header|PJT-☐☐V40WBAA|Input: JST B2P3-VH (LF)(SN)<br>Output: JST B4P-VH (LF)(SN)| ||PJT-☐☐V40WBAB|Input: Molex 26-62-4030<br>Output: Molex 26-60-4040| ||PJT-☐☐V40WBAC|Input: JWT A3963WV2-3P-D<br>Output: JWT A3963WV2-4P| |Wire||AWG 22-18| All parameters are specified at 25°C ambient and AC unless otherwise indicated. **www.DeltaPSU.com (September 2020, Rev. 03)** 2 **TECHNICAL DATASHEET** **PJT Open Frame Power Supply** PJT-40W Series / PJT-□□V40WBA□ ## Environment |Environment||||| |---|---|---|---|---| |Surrounding Air Temperature|Operating|-10°C to +70°C||| ||Storage|-40°C to +85°C||| |Power De-rating||> 50°C de-ratepower by2.5% / °C||| |OperatingHumidity||10 to 95% RH(Non-Condensing)||| |OperatingAltitude||0 to 5,000 Meters (16,400 ft.)||| |Shock Test (Non-Operating)||IEC 60068-2-27, Half Sine Wave: 50G for a duration of 11ms,||| |||3 shocks for each 3 directions||| |Vibration (Operating)||IEC 60068-2-6, Sine Wave: 10Hz to 150Hz @ 25m/S² (2.5G);|IEC 60068-2-6, Sine Wave: 10Hz to 150Hz @ 25m/S² (2.5G);|IEC 60068-2-6, Sine Wave: 10Hz to 150Hz @ 25m/S² (2.5G);| |||10 min per cycle, 90 min per axis for all X, Y, Z direction||| |Protections||||| |Overvoltage||13.2-18.0V,<br>16.5-22.5V,|19.8-27.0V,|26.4-36.0V,| |||Latch Mode<br>Latch Mode|Latch Mode|Latch Mode| |Overload / Overcurrent||> 140% of rated load current, Hiccup Mode,||| |||Non-Latching (Auto-Recovery)||| |Over Temperature||Non-Latching (Auto-Recovery)||| |Short Circuit||Hiccup Mode, Non-Latching (Auto-Recoverywhen the fault is removed||when the fault is removed)| |Protection Against Shock||Class I with PE* connection||| *PE: Primary Earth |||*PE: Primary Earth| |---|---|---| |Reliability Data||| |MTBF||> 700,000 hrs. as per Telcordia SR-332| |Expected Cap Life Time||10 years (115Vac & 230Vac, 50% load @ 40°C)| |Safety Standards / Directives||| |Electrical Safety|TUV Bauart|EN 60950-1/ EN 62368-1| ||UL/cUL recognized|UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E131881)| |||UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E131881)| ||CB scheme|IEC 60950-1/ IEC 62368-1| |CE||In conformance with EMC Directive 2014/30/EU and| |||Low Voltage Directive 2014/35/EU| |Galvanic Isolation|Input to Output|3.0KVac| ||Input to Ground|2.0KVac| ||Output to Ground|0.5KVac| All parameters are specified at 25°C ambient and AC unless otherwise indicated. **www.DeltaPSU.com (September 2020, Rev. 03)** 3 **TECHNICAL DATASHEET** ## **PJT Open Frame Power Supply** PJT-40W Series / PJT-□□V40WBA□ ## EMC |EMC|| |---|---| |Emissions(CE&RE)|CISPR 32, EN 55032, FCC Title 47: Class B| |Immunityto|EN 55024| |Electrostatic Discharge<br>IEC 61000-4-2|Criteria A1)<br>Level 3 Air Discharge: 8kV<br>Level 3 Contact Discharge: 6kV| |Radiated Field<br>IEC 61000-4-3|Level 2 Criteria A1)<br>80MHz-1GHz, 3V/M with 1kHz tone / 80% modulation| |Electrical Fast Transient / Burst<br>IEC 61000-4-4|Level 3 Criteria A1)<br>2kV| |Surge<br>IEC 61000-4-5|Level 3 Criteria A1)<br>Common Mode2): 2kV<br>Differential Mode3): 1kV| |Conducted<br>IEC 61000-4-6|Level 2 Criteria A1)<br>3V with 80% AM| |Power Frequency Magnetic Fields<br>IEC 61000-4-8|Criteria A1)<br>Magnetic field strength 3A/Meter| |Voltage Dips<br>IEC 61000-4-11|30% dip; 10ms Criterion A<br>60% dip; 100ms Criterion B<br>95% dip; 5000ms Criterion B| |Voltage Fluctuation and Flicker|IEC/EN 61000-3-3| ## Voltage Fluctuation and Flicker 1) Criteria A: Normal performance within the specification limits 2) Asymmetrical: Common mode (Line to earth) 3) Symmetrical: Differential mode (Line to line) ## **Block Diagram** All parameters are specified at 25°C ambient and AC unless otherwise indicated. **www.DeltaPSU.com (September 2020, Rev. 03)** 4 **TECHNICAL DATASHEET** ## **PJT Open Frame Power Supply** PJT-40W Series / PJT-□□V40WBA□ ## **Dimensions** **L x W x D:** 76.2 x 50.8 x 22.9 mm [2” x 3”] **==> picture [121 x 59] intentionally omitted <==** **----- Start of picture text -----**<br> =in vot 4 5<br>|<br>| vt) | 1<br>1<br>3 ;<br>**----- End of picture text -----**<br> - **Item Device Description** 1 Input Connector (CN1) Pin 1: Line - Pin 2: NC Pin 3: Neutral - 2 Output Connector (CN2) Pin 1 to 2 : V(+) Pin 3 to 4 : V(-) All parameters are specified at 25°C ambient and AC unless otherwise indicated. **www.DeltaPSU.com (September 2020, Rev. 03)** 5 **TECHNICAL DATASHEET** ## **PJT Open Frame Power Supply** PJT-40W Series / PJT-□□V40WBA□ ## **Engineering Data** Output Load De-rating VS Surrounding Air Temperature ## **Note** 1. Power supply components may degrade, or be damaged, when the power supply is continuously used outside the shaded region, refer to the graph shown in Fig. 1. 2. If the output capacity is not reduced when the surrounding air temperature >50°C, the device will run into Over Temperature Protection. When activated, the output voltage will go into bouncing mode and will recover when the surrounding air temperature is lowered or the load is reduced as far as necessary to keep the device in working condition. 3. Depending on the surrounding air temperature and output load delivered by the power supply, the device can be very hot! 4. If the device has to be mounted in any other orientation, please contact **info@deltapsu.com** for more details. ## **Fig. 1 De-rating for Horizontal Mounting Orientation** > 50°C de-rate power by 2.5% / °C ## Output Load De-rating VS Input Voltage - No output power de-rating for the input voltage from 90Vac to 264Vac - L Frame / Enclosed All parameters are specified at 25°C ambient and AC unless otherwise indicated. **www.DeltaPSU.com (September 2020, Rev. 03)** 6 **TECHNICAL DATASHEET** ## **PJT Open Frame Power Supply** PJT-40W Series / PJT-□□V40WBA□ ## **Assembly & Installation** Any excessive twisting or bending may damage the device’s PCB. Please handle the device with care. **Base Mounting (Horizontal) Fig. 2 Recommended Mounting Orientation** Use cable of AWG No. 22-18. Please refer to Table 1 for the recommended Mating Connector and Terminal **.** |**Table 1**<br>||**Input / Output**<br>~~es~~|**Power Supply Header**|**Mating Connector**|**Terminal**| |---|---|---|---|---| |**A – JST connector**<br>|<br>||Input<br>~~es~~<br>~~ee~~|B2P3-VH(LF)(SN)<br>~~ee~~|VHR-3N<br>~~ee~~|SVH-21T-P1.1| ||Output<br>~~es~~<br>~~ee~~<br>|<br>||B4P-VH(LF)(SN)<br>~~ee~~<br>~~ee~~|VHR-4N<br>~~ee~~<br>~~ee~~|SVH-21T-P1.1<br>~~ee~~| |**B – Molex connector**<br>||Input<br>~~ee~~<br>|<br>||26-62-4030<br>~~ee~~<br>~~ee~~|09-50-3031<br>~~ee~~<br>~~ee~~|08-52-0071<br>~~ee~~| ||Output<br>~~ee~~<br>|<br>||26-60-4040<br>~~ee ~~<br>~~ee~~|09-50-3041<br> ~~ee~~<br>~~ee ~~|08-52-0071<br> ~~ee~~| |**C – JWT connector**|Input|A3963WV2-3P-D|A3963H02-3P|A3963TOP-2| ||Output|A3963WV2-4P|A3963H02-4P|A3963TOP-2| ## Safety Instructions - If the device has to be mounted in any other orientation, please contact info@deltapsu.com for more details. - The device is not recommended to be placed on surface with low thermal conductivity, such as plastics, for example. - For safety reasons, please ensure the mounted device is kept at ≥ 4mm (0.16 inch) safety distance at all sides from other components and equipments. Please insert an insulation sheet between the system and product, if the safety distance is less than 4mm. In addition, to ensure sufficient convection cooling, always maintain a distance of ≥ 20mm (0.79 inch) from ventilated surfaces while the device is in operation. - Note that the device can become very hot depending on the ambient temperature and load of the power supply. Do not touch the device while it is in operation or immediately after power is turned OFF. Risk of burning! - Do not touch the terminals while power is being supplied. Risk of electric shock. - Prevent any foreign metal, particles or conductors from entering the device through the openings during installation. It may cause: Electric shock; Safety Hazard; Fire; Product failure - The power supply must be mounted by metal screws onto a grounded metal surface. It is highly recommended that the Earth terminal on the connector be connected to the grounded metal surface. All parameters are specified at 25°C ambient and AC unless otherwise indicated. 7 **www.DeltaPSU.com (September 2020, Rev. 03)** **TECHNICAL DATASHEET** ## **PJT Open Frame Power Supply** PJT-40W Series / PJT-□□V40WBA□ ## **Functions** ## Start-up Time The time required for the output voltage to reach 90% of its final steady state set value, after the input voltage is applied. ## Rise Time The time required for the output voltage to change from 10% to 90% of its final steady state set value. ## Hold-up Time Time between the collapse of the AC input voltage, and the output falling to 95% of its steady state set value. ## ■ **Graph illustrating the Start-up Time, Rise Time, and Hold-up Time** ## Inrush Current Inrush current is the peak, instantaneous, input current measured and, occurs when the input voltage is first applied. For AC input voltages, the maximum peak value of inrush current will occur during the first half cycle of the applied AC voltage. This peak value decreases exponentially during subsequent cycles of AC voltage. ## Dynamic Response The power supply output voltage will remain within ±5% of its steady state value, when subjected to a dynamic load from 0 to 100% of its rated current. All parameters are specified at 25°C ambient and AC unless otherwise indicated. **www.DeltaPSU.com (September 2020, Rev. 03)** 8 **TECHNICAL DATASHEET** ## **PJT Open Frame Power Supply** PJT-40W Series / PJT-□□V40WBA□ ## Overload & Overcurrent Protections (Auto-Recovery) The power supply’s Overload (OLP) and Overcurrent (OCP) Protections will be activated when output current exceeds 140% of IO (Max load). In such occurrence, the VO will start to droop and once the power supply has reached its maximum power limit, the protection is activated and the power supply will go into “Hiccup mode” (Auto-Recovery). The power supply will recover once the fault condition of the OLP and OCP is removed and IO is back within the specifications. ## Overvoltage Protection (Latch Mode) The power supply’s overvoltage circuit will be activated when its internal feedback circuit fails. The output voltage shall not exceed its specifications defined on Page 3 under “Protections”. Power supply will latch off, and require removal/re-application of input AC voltage in order to restart. ## **The power supply should be latch.** ## Over Temperature Protection (Auto-Recovery) It is not recommended to prolong the duration of IO when it is <140% but >100%, since it may cause damage to the PSU. ## Short Circuit Protection (Auto-Recovery) The power supply’s output OLP/OCP function also provides protection against short circuits. When a short circuit is applied, the output current will operate in “Hiccup mode”, as shown in the illustration in the OLP/OCP section on this page. The power supply will return to normal operation after the short circuit is removed. As described in load de-rating section, the power supply also has Over Temperature Protection (OTP). In the event of a higher operating temperature at 100% load, the power supply will run into OTP when the operating temperature is beyond what is recommended in the de-rating graph. When activated, the output voltage will go into bouncing mode until the temperature drops to its normal operating temperature as recommended in the de-rating graph. ## **Others** ## Attention Delta provides all information in the datasheets on an “AS IS” basis and does not offer any kind of warranty through the information for using the product. In the event of any discrepancy between the information in the catalog and datasheets, the datasheets shall prevail (please refer to www.DeltaPSU.com for the latest datasheets information). Delta shall have no liability of indemnification for any claim or action arising from any error for the provided information in the datasheets. Customer shall take its responsibility for evaluation of using the product before placing an order with Delta. Delta reserves the right to make changes to the information described in the datasheets without notice. All parameters are specified at 25°C ambient and AC unless otherwise indicated. **www.DeltaPSU.com (September 2020, Rev. 03)** 9
Updated at April 22, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →