Image not available
Illustrative purposes only
PJ-24V30WBNA
AC/DC Open Frame Power Supply (PSU), ITE, 1 Output, 31.2 W, 85V AC to 264V AC, Adjustable, Fixed
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: DELTA ELECTRONICS
- Product type: AC / DC Open Frame Power Supplies
- SVHC: To Be Advised
- Product Range: PJ Series
- No. of Outputs: 1 Output
- Input Voltage VAC: 85V AC to 264V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 1.3A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 24VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
- Power Rating (Forced Cooling): -
- Power Rating (Convection Cooling): 31.2W
| Delivery and price | |
|---|---|
| Units per pack | 250 |
| Price | 16.58 € |
| Current stock | 10+ |
| Lead time | 30 days |
**TECHNICAL DATASHEET**
**PJ Open Frame Power Supply** 24V 30W 1 Phase / PJ-24V30W□NA
## **PJ**
## **Highlights & Features**
- Universal AC input voltage range
- Low Inrush Current / Low Leakage Current
- High efficiency
- Conforms to harmonic current IEC/EN 61000-3-2, Class A
- Conformal coating on PCBA to protect against chemical and dust pollutants
- Versatile configuration options: Open Frame, L Frame, Enclosed
- Long life capacitors
## **Safety Standards**
CB Certified for worldwide use
**Model Number:** PJ-24V30W□NA **Unit Weight: Open Frame** : 0.11 kg (0.24 lb) **Enclosed** : 0.20 kg (0.44 lb) **Dimensions (L x W x D): Open Frame** : 105 x 50 x 25.6 mm (4.13 x 1.97 x 1.01 inch) **Enclosed** : 25 x 60 x 36 mm (4.92 x 2.36 x 1.42 inch)
## **General Description**
The PJ series of Open Frame Power Supply comes with universal AC input at 85Vac to 264Vac. Other features include low leakage / Inrush current and conformal coating on the PCBAs to provide protection against dust and chemical pollutants. All products fulfill Harmonic Current Emission according to IEC/EN 61000-3-2. The PJ series is certified for EMC standards according to EN 55011 for industrial, scientific and medical (ISM) radio-frequency equipment and EN 55032 for Industrial Technology Equipment (ITE) radiofrequency equipment and EMS according to EN 55024. In addition, the detachable input and output connectors are from JST and only recognized Japanese capacitors are used.
Metal chassis and case cover are available as options for different installation preferences. The PJ series conforms to major international safety standards according to EN/UL 62368-1 standards and are fully compliant with RoHS Directive for environmental protection.
## **Model Information**
PJ Open Frame Power Supply
|**ModelNumber**|**ModelNumber**|**Input Voltage Range**|**Input Voltage Range**|**Rated OutputVoltage**|**Rated OutputVoltage**|**Rated Output Current**|**Rated Output Current**|
|---|---|---|---|---|---|---|---|
|PJ-24V30W□NA||85-264Vac||24Vdc||1.30A||
|**Model Numbering**||||||||
||||||**CC Code**|||
|**PJ –**|**24V**|**30W**|□||**N**||**A**|
|PJ Series|Output Voltage|Output Power|Product Type||Remote ON/OFF Function||Delta Standard|
||||B - Open Frame||N - No Remote ON/OFF|||
||||L - L Frame|||||
||||C - Enclosed|||||
## **Model Numbering**
All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (October 2020, Rev. 04)**
1
**TECHNICAL DATASHEET**
## **PJ Open Frame Power Supply** 24V 30W 1 Phase / PJ-24V30W□NA
## **Specifications**
## Input Ratings / Characteristics
|**Specifications**<br>Input Ratings / Characteristics||
|---|---|
|Nominal Input Voltage|100-240Vac|
|Input Voltage Range|85-264Vac|
|Nominal Input Frequency|50-60Hz|
|Input FrequencyRange|47-63Hz|
|Input Current|0.65A typ. @ 100Vac, 0.35A typ. @ 200Vac|
|Efficiencyat 100% Load|85.0% typ.@100Vac, 86.0% typ.@200Vac|
|Max Inrush Current(Cold Start)|15A typ.@100Vac, 30A typ.@200Vac|
|Leakage Current|0.1mA@100Vac, 0.2mA@240Vac|
## Output Ratings / Characteristics*
|Output Ratings / Characteristics*||
|---|---|
|Nominal Output Voltage|24Vdc|
|Output Voltage Tolerance|± 1%(initial set point tolerance from factory)|
|Output Voltage Adjustment Range|21.6-26.4Vdc|
|Output Current|1.30A|
|Output Power|31.2W|
|Line Regulation|< 96mV|
|Load Regulation|< 150mV|
|Ripple(20MHz)|< 120mVpp@0°C to 50°C, < 160mVpp@-10°C to 0°C|
|Ripple Noise(20MHz)|< 150mVpp@0°C to 50°C, < 180mVpp@-10°C to 0°C|
|Start-up Time|500ms typ. @ 100Vac|
|Hold-up Time|20ms typ.@100Vac(100% Load)|
|Dynamic Response<br>(Overshoot & Undershoot O/P Voltage)|± 5% @ 0-50% load and 50-100% load|
|Start-up with Capacitive Loads|8,000µF Max|
*For power de-rating from 50°C to 70°C, see power de-rating on page 3
## Mechanical
|Mechanical|Mechanical||
|---|---|---|
|Case Chassis||SGCC|
|Case Cover||SGCC|
|Dimensions|Open Frame<br>Enclosed|105 x 50 x 25.6 mm (4.13 x 1.97 x 1.01 inch)<br>125 x 60 x 36 mm(4.92 x 2.36 x 1.42 inch)|
|Unit Weight|Open Frame<br>Enclosed|0.11 kg (0.24 lb)<br>0.20 kg (0.44 lb)|
|CoolingSystem||Convection|
|Terminal|Input|JST B3P5-VH(LF)(SN)|
||Output|JST B4P-VH(LF)(SN)|
|Wire||AWG 22-18|
All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (October 2020, Rev. 04)**
2
**TECHNICAL DATASHEET**
**PJ Open Frame Power Supply** 24V 30W 1 Phase / PJ-24V30W□NA
## Environment
|Environment|||
|---|---|---|
|Surrounding Air Temperature|Operating|-10°C to +70°C|
||Storage|-25°C to +75°C|
|Power De-rating|Mounting Orientation A|> 50°C de-rate power by 2.5% / °C<br>< 90Vac de-ratepower by2% / V|
|OperatingHumidity||5 to 95% RH(Non-Condensing)|
|OperatingAltitude||0 to 5,000 Meters(16,400 ft)|
|Shock Test (Non-Operating)||IEC 60068-2-27, 196.1m/S² (20G),11ms, once along X, Y, and Z<br>axis|
|Vibration (Operating)||IEC 60068-2-6, 10Hz to 55Hz @ 19.6m/S² (2G); 60 min per axis<br>for all X, Y, Z direction|
## Protections
|Protections||
|---|---|
|Overvoltage|27.6-33.6V, Latch Mode|
|Overload / Overcurrent|> 105% of rated load current, Hiccup Mode,<br>Non-Latching (Auto-Recovery)|
|Over Temperature|Latch Mode|
|Short Circuit|Hiccup Mode, Non-Latching<br>(Auto-Recoverywhen the fault is removed)|
|Protection Against Shock|Class I with PE* connection|
*PE: Primary Earth
## Reliability Data
|Reliability Data||
|---|---|
|MTBF|> 200,000 hrs. asper JEITA RCR-9102B|
|Expected CapLife Time|10years(115Vac, 50% load@40°C)|
## Safety Standards / Directives
|Safety Standards / Directives|||
|---|---|---|
|Electrical Safety|TUV Bauart<br>UL/cUL recognized<br>CB scheme|EN 60950-1, EN 62368-1<br>UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E131881)<br>UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E131881)<br>IEC 60950-1, IEC 62368-1|
|CE||In conformance with EMC Directive 2014/30/EU and<br>Low Voltage Directive 2014/35/EU|
|Galvanic Isolation|Input to Output|3.0KVac|
||Input to Ground|2.0KVac|
||Output to Ground|0.5KVac|
All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (October 2020, Rev. 04)**
3
**TECHNICAL DATASHEET**
**PJ Open Frame Power Supply** 24V 30W 1 Phase / PJ-24V30W□NA
|EMC||
|---|---|
|Emissions(CE & RE)|CISPR 32, EN 55032, FCC Title 47: Class B|
|Immunityto||
|Electrostatic Discharge<br>IEC 61000-4-2|Level 4 Criteria A1)<br>Air Discharge: 15kV<br>Contact Discharge: 8kV|
|Radiated Field<br>IEC 61000-4-3|Level 3 Criteria A1)<br>80MHz-1GHz, 10V/M with 1kHz tone / 80% modulation|
|Electrical Fast Transient / Burst<br>IEC 61000-4-4|Level 3 Criteria A1)<br>2kV|
|Surge<br>IEC 61000-4-5|Level 3 Criteria A1)<br>Common Mode2): 2kV<br>Differential Mode3): 1kV|
|Conducted<br>IEC 61000-4-6|Level 3 Criteria A1)<br>150kHz-80MHz, 10Vrms|
|Power Frequency Magnetic Fields<br>IEC 61000-4-8|Criteria A1)<br>Magnetic field strength 30A/Meter|
|Voltage Dips<br>IEC 61000-4-11|100% dip; 1 cycle (20ms); Self Recoverable|
|Low Energy Pulse Test (Ring Wave)<br>IEC 61000-4-12|Level 3 Criteria A1)<br>Common Mode2): 2kV<br>Differential Mode3): 1kV|
|Harmonic Current Emission|IEC/EN 61000-3-2, Class A|
|Voltage Fluctuation and Flicker|IEC/EN 61000-3-3|
1) Criteria A: Normal performance within the specification limits
2) Asymmetrical: Common mode (Line to earth)
3) Symmetrical: Differential mode (Line to line)
## **Block Diagram**
All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (October 2020, Rev. 04)**
4
## **TECHNICAL DATASHEET PJ Open Frame Power Supply** 24V 30W 1 Phase / PJ-24V30W□NA
## **Dimensions**
## **Open Frame**
**(L x W x D):** 105 x 50 x 25.6 mm (4.13 x 1.97 x 1.01 inch)
## **L Frame**
**(L x W x D):** 125 x 60 x 36 mm (4.92 x 2.36 x 1.42 inch)
- **Item Device Description Notes** 1 Input Connector • Dimensions are in mm 2 Output Connector • For information on I/O Connector and Housing, please refer to Table 1 (Page 6). • For L Frame type: There are 6 threaded mounting holes and 4 normal mounting
- 3 VR holes.
- 4 Chassis • For Open Frame type: There are 4 normal mounting holes. • Recommended mounting torque for tightening: 4~8Kgf.cm.
All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (October 2020, Rev. 04)**
5
## **TECHNICAL DATASHEET PJ Open Frame Power Supply** 24V 30W 1 Phase / PJ-24V30W□NA
## **Enclosed**
**(L x W x D):** 125 x 60 x 36 mm (4.92 x 2.36 x 1.42 inch)
## **Item Device Description**
## **Notes**
- 1 Input Connector • Dimensions are in mm
- 2 Output Connector
- 3 VR
- 4 Cover
- For information on I/O Connector and Housing, please refer to Table 1 (Page 6).
- For Enclosed type: There are 6 threaded mounting holes and 4 normal mounting holes.
-
- Recommended mounting torque for tightening: 4~8Kgf.cm.
- 5 Chassis
## **Assembly & Installation**
## Assembly Reference
## ■ Open Frame
## ■ L Frame / Enclosed
For safety reasons, please ensure the mounted device is kept at ≥ 4mm safety distance at all sides from other components and equipments. **Please insert an insulation sheet between the system and product, if the safety distance is less than 4mm.**
Use flexible cable (stranded or solid) of AWG No. 22-18. Please refer to Table 1 for the recommended Housing and Terminal.
|**Table 1**|**Connector (Board Mounting)**|**Housing**|**Terminal**|
|---|---|---|---|
|**Input (JST)**|B3P5-VH(LF)(SN)|VHR-5N|SVH-21T-P1.1|
|**Output (JST)**|B4P-VH(LF)(SN)|VHR-4N||
All parameters are specified at 25°C ambient and AC input unless otherwise indicated. 6 **www.DeltaPSU.com (October 2020, Rev. 04)**
**TECHNICAL DATASHEET**
## **PJ Open Frame Power Supply** 24V 30W 1 Phase / PJ-24V30W□NA
## Mounting Orientation
-
- Any excessive twisting or bending may damage the device’s PCB. Please handle the device with care.
- The device is not recommended to be placed on low thermal conductive surfaces. For example, plastics.
- • Prevent any foreign metal, particles or conductors from entering the device through the openings during installation. It may cause: -Electric shock; Safety hazard; Product failure.
- • **The power supply must be mounted by metal screws onto a grounded metal surface. It is highly recommended that the Earth terminal on the connector be connected to the grounded metal surface.**
## **Engineering Data**
## **Convection**
Output Load De-rating VS Surrounding Air Temperature
■ Open Frame / L Frame
## ■ Enclosed
Fig.1.1 De-rating for Mounting Orientation A to F > 50°C de-rate power by 2.5% / °C
Fig.1.2 De-rating for Mounting Orientation A to F > 40°C de-rate power by 2.5% / °C
All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (October 2020, Rev. 04)**
7
**TECHNICAL DATASHEET**
## **PJ Open Frame Power Supply** 24V 30W 1 Phase / PJ-24V30W□NA
## **Forced Cooling** (Air Velocity > 0.7m/s)
Output Load De-rating VS Surrounding Air Temperature
## ■ Air Flow Direction
## ■ Open Frame / L Frame
■ Enclosed
- Fig.1.3 De-rating for Mounting Orientation A to F > 60°C de-rate power by 2% / °C
Fig.1.4 De-rating for Mounting Orientation A to F > 50°C de-rate power by 2% / °C
## **Notes**
1. Power supply components may degrade, or be damaged, when the power supply is continuously used outside the shaded region, refer to the graphs shown above.
2. If the output capacity is not reduced when the surrounding air temperature is more than the upper limit temperature, the device will run into Over Temperature Protection. When activated, the output voltage will go into bouncing mode and will recover when the surrounding air temperature is lowered or the load is reduced as far as necessary to keep the device in working condition.
3. Depending on the surrounding air temperature and output load delivered by the power supply, the device housing can be very hot!
4. If the device has to be mounted in any other orientation, please do not hesitate to contact **info@deltapsu.com** for more details.
All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (October 2020, Rev. 04)**
8
## **TECHNICAL DATASHEET PJ Open Frame Power Supply** 24V 30W 1 Phase / PJ-24V30W□NA
## Output Load De-rating VS. Input Voltage
■ No output power de-rating for the input voltage range from 90Vac to 264Vac
Fig.1.5 De-rating for Mounting Orientation A to F < 90Vac de-rate power by 2% / V
## **Functions**
## Start-up Time
The time required for the output voltage to reach 90% of its final steady state set value, after the input voltage is applied.
## Rise Time
The time required for the output voltage to change from 10% to 90% of its final steady state set value.
## Hold-up Time
Time between the collapse of the AC input voltage, and the output falling to 95% of its steady state set value.
## ■ **Graph illustrating the Start-up Time, Rise Time, and Hold-up Time**
All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (October 2020, Rev. 04)**
9
**TECHNICAL DATASHEET**
## **PJ Open Frame Power Supply** 24V 30W 1 Phase / PJ-24V30W□NA
## Dynamic Response
The power supply output voltage will remain within ±5% of its steady state value, when subjected to a dynamic load 0% to 100% of its rated current.
## Short Circuit Protection (Auto-Recovery)
The power supply’s output OLP/OCP function also provides protection against short circuits. When a short circuit is applied, the output current will operate in “Hiccup mode”, as shown in the illustration in the OLP/OCP section on this page. The power supply will return to normal operation after the short circuit is removed.
## Inrush Current
Inrush current is the peak, instantaneous, input current measured and, occurs when the input voltage is first applied. For AC input voltages, the maximum peak value of inrush current will occur during the first half cycle of the applied AC voltage. This peak value decreases exponentially during subsequent cycles of AC voltage.
## Overload & Overcurrent Protections (Auto-Recovery)
The power supply’s Overload (OLP) and Overcurrent (OCP) Protections will be activated when output current exceeds 105% of IO (Max load). In such occurrence, the VO will start to droop and once the power supply has reached its maximum power limit, the protection is activated and the power supply will go into “Hiccup mode” (Auto-Recovery). The power supply will recover once the fault condition of the OLP and OCP is removed and IO is back within the specifications.
Additionally, if the IO is <105% but >100% for a prolong period of time (depending on the load), the Over Temperature Protection (OTP) will be activated due to high temperature on critical components. The power supply will then go into latch mode until the fault is removed and the mains is reapplied.
## Over Temperature Protection
## Overvoltage Protection
The power supply’s overvoltage circuit will be activated when its internal feedback circuit fails. The output voltage shall not exceed its specifications defined on Page 3 under “Protections”.
As mentioned above, the power supply also has Over Temperature Protection (OTP). This is activated when the overload condition persists for an extended duration and the output current is below the overload trigger point but >100% load. In the event of a higher operating condition at 100% load, the power supply will run into OTP when the surrounding air temperature is higher than the operating temperature. When activated, the output voltage will go into latch mode until the mains is reapplied and the surrounding air temperature drops to its normal operating temperature.
## **The power supply should be latch.**
All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (October 2020, Rev. 04)**
10
**TECHNICAL DATASHEET**
## **PJ Open Frame Power Supply** 24V 30W 1 Phase / PJ-24V30W□NA
## **Others**
## Conformal Coating
## **The Protective Coating Technology**
Delta Electronics Group has designed the perfect dipping technique which penetrates everywhere including under device, and prevents leakage. The conformal coating dipping can be applied to PCBs or circuit board. The coating preserves the performance of precision electronic primarily by preventing ionizable contaminants such as salt from reaching circuit nodes, where the material slumps around sharp edges. This can be a problem especially in highly conversing atmosphere.
## Attention
Delta provides all information in the datasheets on an “AS IS” basis and does not offer any kind of warranty through the information for using the product. In the event of any discrepancy between the information in the catalog and datasheets, the datasheets shall prevail (please refer to www.DeltaPSU.com for the latest datasheets information). Delta shall have no liability of indemnification for any claim or action arising from any error for the provided information in the datasheets. Customer shall take its responsibility for evaluation of using the product before placing an order with Delta.
Delta reserves the right to make changes to the information described in the datasheets without notice.
All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (October 2020, Rev. 04)**
11
Updated at April 22, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →