PHP-3500-48
AC/DC Enclosed Power Supply (PSU), 127 to 370VDC, ITE & Household, 1 Outputs, 3.504 kW, 48 VDC
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC Enclosed Power Supplies
- SVHC: No SVHC (25-Jun-2025)
- Product Range: PHP-3500 Series
- No. of Outputs: 1Outputs
- Output Power Max: 3.504kW
- Input Voltage VAC: 90V AC to 264V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 73A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 48VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE & Household
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 897.84 € |
| Current stock | 10+ |
| Lead time | 30 days |
**-** 3500W Conduction Cooling with PFC Switching Supply **PHP 3500 series** **==> picture [187 x 52] intentionally omitted <==** **----- Start of picture text -----**<br> BauarSicherheitbeegelodwacmat geprufto ges g<br>AL : www.ID 2000000000tuv.com<br>UL62368-1 EN62368-1 2 TPTC004 Hl CBCE IEC62368-1<br>■ Features<br>**----- End of picture text -----**<br> ## ■ * - 30 +70 ℃ ## ■ Industrial automation machinery Industrial control system Mechanical and electrical equipment Electronic instruments, equipments or apparatus Household appliances Optional cold plate for quick implementation Ⅲ ## ■ PHP-3500 series is a 3500W single-output slim type power supply with 60mm of low profile design. Adopting the full range 90~264VAC input, the entire series provides an output voltage line of 24V and 48V. In addition to the high efficiency up to 96%, that the whole series operates from -30℃ ~ +70℃ under air convection without fan. PHP-3500 has the complete protection functions and 2G anti-vibration capability; it complies with the international safety regulations such as TUV EN62368-1, UL62368-1, and design refers to EN61558-1 and EN60335-1. PHP-3500 series serves as a high performance power supply solution for various industrial applications. ## ■ _File Name:PHP-3500-SPEC 2020-03-27_ **- PHP 3500 series** 3500W Conduction Cooling with PFC Switching Supply ## **SPECIFICATION** ## **MODEL** |**VOLTAGE ADJ. RANGE**<br>105 ~ 115% rated output power<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**OUTPUT**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**Note.4**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**Note.10**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**OVER TEMPERATURE**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**AC CURRENT (Typ.)**<br>1500ms, 60ms/230VAC at full load<br>90 ~ 264VAC 127 ~ 370VDC<br>Cold start 80A/230VAC<br>2mA / 240VAC<br>-30 ~ +70<br>Baseplate temperature (Refer to “Derating Curve")<br>℃<br>20 ~ 90% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃<br>±<br>℃<br>℃)<br>0.03%/<br>(0 ~ 50<br>10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes<br>183.4K hrs min.<br>Telcordia SR-332 (Bellcore) ; 56.26K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>PF<br>0.95/230VAC at full load<br>≥<br>16ms/230VAC at 75% load 10ms/230VAC at full load<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCE Note.3**<br>℃<br>ncludes set up tolerance,<br>derating curve<br>℃<br>℃<br>**ENVIRONMENT**<br>**PROTECTION**<br>380*141.4*60mm (L*W*H)<br>Protection type :Shut down O/P voltage,re-power on to recover<br>Protection type :Shut down O/P voltage, recovers automatically after temperature goes down<br>20A/230VAC<br>**RATED POWER**<br>4.5Kg;4pcs/19Kg/2.46CUFT<br>47 ~ 63Hz<br>Protection type : Constant current limiting, shut down O/P voltage 5 sec. after O/P voltage is down low, re-power on to recover<br>**FUNCTION**<br>**REMOTE ON/OFF CONTROL**<br>**AUXILIARY POWER**<br>**DC-OK SIGNAL**<br>Power ON : Short circuit Power OFF : Open circuit<br>12V@0.5A tolerance 10%, ripple 150mVp-p<br>±<br>The TTL signal out, PSU turn on = -0.5 ~ 0.5V ; PSU turn off = 3.5 ~ 5.5V. Please refer to the Function Manual.<br>**SAFETY STANDARDS**<br>**SAFETY &**<br>**EMC**<br>**(Note.7,8)**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC<br>I/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25<br>/ 70%RH<br>℃<br>UL62368-1, CAN/CSA C22.2<br>,TUV EN62368-1,<br>approved ; design refers to EN61558-1, EN60335-1<br>No. 62368-1<br>EAC TP TC 004<br>**MTBF**<br>**PACKING**<br>Adjustment of constant current level is allowable to 20 ~ 100% of rated current. Please refer to the Function Manual.<br>**OUTPUT VOLTAGE**<br>**PROGRAMMABLE(PV)Note.5,6**<br>**OUTPUT CURRENT**<br>**PROGRAMMABLE(PC) Note.6**<br>By built-in potentiometer, SVR<br>300mVp-p<br>480mVp-p<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±1.0%<br>±1.0%<br>95%<br>96%<br>30 ~ 36V<br>60 ~ 72V<br>**PHP-3500-24**<br>**PHP-3500-48**<br>3480W<br>3504W<br>24V<br>48V<br>145A<br>73A<br>24~28.8V<br>48~57.6V<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>**Parameter**<br>**Parameter**<br>ESD<br>Radiated<br>EFT / Burst<br>Surge<br>Conducted<br>Magnetic Field<br>Voltage Dips and Interruptions<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>**Standard**<br>**Standard**<br>EN55032 (CISPR32)<br>EN55032 (CISPR32)<br>EN61000-3-12<br>EN61000-3-3<br>EN61000-4-2<br>EN61000-4-3<br>EN61000-4-4<br>EN61000-6-2<br>EN61000-4-6<br>EN61000-4-8<br>EN61000-4-11<br>**Test Level / Note**<br>**Test Level / Note**<br>Level 3, 8KV air ; Level 2, 4KV contact<br>Level 3<br>Level 3<br>2KV/Line-Line 4KV/Line-Earth<br>Level 3<br>Level 4<br>>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods<br>Class B<br>Class A<br>-----<br>-----<br>**OVER VOLTAGE CATEGORY** Ⅱ; According to EN61558; altitude up to 5000 meters.<br>Adjustment of output voltage is allowable to 50 ~ 120% of nominal output voltage. Please refer to the Function Manual.<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25 _of ambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance<br>line regulation and load regulation.<br>4. Derating may be needed under low input voltages. Please check the<br>for more details.<br>5. Without water or fan cooling to provide adequate heat dissipation, OTP might be triggered if trimming output voltage by PV signal toward upper or bottom<br>limits of nominal voltage. Under such condition, enhanced cooling on PSU is highly recommended.<br>6. PV/PC function when users are not operating on PMBus. SVR functions when users are neither operation on PMBus nor using PV/PC.<br>7. Need additional EMI filter to meet regulations of EMC conducted and radiated emission. Characteristics of EMI filter please refer to the table, Minimum<br>Insertion Loss.<br>8. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a 600mm*900mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http:/Avww.meanwell.com)<br>9. The ambient temperature derating of 3.5<br>/1000m with fanless models and of 5<br>+ /1000m with fan models for operating altitude higherthan 2000m(6500ft).<br>10. The efficiency is measured at75% load.|**VOLTAGE ADJ. RANGE**<br>105 ~ 115% rated output power<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**OUTPUT**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**Note.4**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**Note.10**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**OVER TEMPERATURE**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**AC CURRENT (Typ.)**<br>1500ms, 60ms/230VAC at full load<br>90 ~ 264VAC 127 ~ 370VDC<br>Cold start 80A/230VAC<br>2mA / 240VAC<br>-30 ~ +70<br>Baseplate temperature (Refer to “Derating Curve")<br>℃<br>20 ~ 90% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃<br>±<br>℃<br>℃)<br>0.03%/<br>(0 ~ 50<br>10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes<br>183.4K hrs min.<br>Telcordia SR-332 (Bellcore) ; 56.26K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>PF<br>0.95/230VAC at full load<br>≥<br>16ms/230VAC at 75% load 10ms/230VAC at full load<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCE Note.3**<br>℃<br>ncludes set up tolerance,<br>derating curve<br>℃<br>℃<br>**ENVIRONMENT**<br>**PROTECTION**<br>380*141.4*60mm (L*W*H)<br>Protection type :Shut down O/P voltage,re-power on to recover<br>Protection type :Shut down O/P voltage, recovers automatically after temperature goes down<br>20A/230VAC<br>**RATED POWER**<br>4.5Kg;4pcs/19Kg/2.46CUFT<br>47 ~ 63Hz<br>Protection type : Constant current limiting, shut down O/P voltage 5 sec. after O/P voltage is down low, re-power on to recover<br>**FUNCTION**<br>**REMOTE ON/OFF CONTROL**<br>**AUXILIARY POWER**<br>**DC-OK SIGNAL**<br>Power ON : Short circuit Power OFF : Open circuit<br>12V@0.5A tolerance 10%, ripple 150mVp-p<br>±<br>The TTL signal out, PSU turn on = -0.5 ~ 0.5V ; PSU turn off = 3.5 ~ 5.5V. Please refer to the Function Manual.<br>**SAFETY STANDARDS**<br>**SAFETY &**<br>**EMC**<br>**(Note.7,8)**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC<br>I/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25<br>/ 70%RH<br>℃<br>UL62368-1, CAN/CSA C22.2<br>,TUV EN62368-1,<br>approved ; design refers to EN61558-1, EN60335-1<br>No. 62368-1<br>EAC TP TC 004<br>**MTBF**<br>**PACKING**<br>Adjustment of constant current level is allowable to 20 ~ 100% of rated current. Please refer to the Function Manual.<br>**OUTPUT VOLTAGE**<br>**PROGRAMMABLE(PV)Note.5,6**<br>**OUTPUT CURRENT**<br>**PROGRAMMABLE(PC) Note.6**<br>By built-in potentiometer, SVR<br>300mVp-p<br>480mVp-p<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±1.0%<br>±1.0%<br>95%<br>96%<br>30 ~ 36V<br>60 ~ 72V<br>**PHP-3500-24**<br>**PHP-3500-48**<br>3480W<br>3504W<br>24V<br>48V<br>145A<br>73A<br>24~28.8V<br>48~57.6V<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>**Parameter**<br>**Parameter**<br>ESD<br>Radiated<br>EFT / Burst<br>Surge<br>Conducted<br>Magnetic Field<br>Voltage Dips and Interruptions<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>**Standard**<br>**Standard**<br>EN55032 (CISPR32)<br>EN55032 (CISPR32)<br>EN61000-3-12<br>EN61000-3-3<br>EN61000-4-2<br>EN61000-4-3<br>EN61000-4-4<br>EN61000-6-2<br>EN61000-4-6<br>EN61000-4-8<br>EN61000-4-11<br>**Test Level / Note**<br>**Test Level / Note**<br>Level 3, 8KV air ; Level 2, 4KV contact<br>Level 3<br>Level 3<br>2KV/Line-Line 4KV/Line-Earth<br>Level 3<br>Level 4<br>>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods<br>Class B<br>Class A<br>-----<br>-----<br>**OVER VOLTAGE CATEGORY** Ⅱ; According to EN61558; altitude up to 5000 meters.<br>Adjustment of output voltage is allowable to 50 ~ 120% of nominal output voltage. Please refer to the Function Manual.<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25 _of ambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance<br>line regulation and load regulation.<br>4. Derating may be needed under low input voltages. Please check the<br>for more details.<br>5. Without water or fan cooling to provide adequate heat dissipation, OTP might be triggered if trimming output voltage by PV signal toward upper or bottom<br>limits of nominal voltage. Under such condition, enhanced cooling on PSU is highly recommended.<br>6. PV/PC function when users are not operating on PMBus. SVR functions when users are neither operation on PMBus nor using PV/PC.<br>7. Need additional EMI filter to meet regulations of EMC conducted and radiated emission. Characteristics of EMI filter please refer to the table, Minimum<br>Insertion Loss.<br>8. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a 600mm*900mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http:/Avww.meanwell.com)<br>9. The ambient temperature derating of 3.5<br>/1000m with fanless models and of 5<br>+ /1000m with fan models for operating altitude higherthan 2000m(6500ft).<br>10. The efficiency is measured at75% load.|**PHP-3500-24**|**PHP-3500-24**|**PHP-3500-48**|**PHP-3500-48**| |---|---|---|---|---|---| ||**DC VOLTAGE**|24V||48V|| ||**RATED CURRENT**|145A||73A|| ||**RATED POWER**|3480W||3504W|| ||**RIPPLE & NOISE (max.) Note.2**|300mVp-p||480mVp-p|| ||**VOLTAGE ADJ. RANGE**|By built-in potentiometer, SVR<br>24~28.8V<br>48~57.6V|||| ||**VOLTAGE TOLERANCE Note.3**|±1.0%||±1.0%|| ||**LINE REGULATION**|±0.5%||±0.5%|| ||**LOAD REGULATION**|±0.5%||±0.5%|| ||**SETUP, RISE TIME**|1500ms, 60ms/230VAC at full load|||| ||**HOLD UP TIME (Typ.)**|16ms/230VAC at 75% load 10ms/230VAC at full load|||| ||**VOLTAGE RANGE**<br>**Note.4**|90 ~ 264VAC 127 ~ 370VDC|||| ||**FREQUENCY RANGE**|47 ~ 63Hz|||| ||**POWER FACTOR (Typ.)**|PF<br>0.95/230VAC at full load<br>≥|||| ||**EFFICIENCY (Typ.)**<br>**Note.10**|95%||96%|| ||**AC CURRENT (Typ.)**|20A/230VAC|||| ||**INRUSH CURRENT (Typ.)**|Cold start 80A/230VAC|||| ||**LEAKAGE CURRENT**|2mA / 240VAC|||| ||**OVERLOAD**|105 ~ 115% rated output power<br>Protection type : Constant current limiting, shut down O/P voltage 5 sec. after O/P voltage is down low, re-power on to recover|||| ||**OVER VOLTAGE**|Protection type :Shut down O/P voltage,re-power on to recover<br>30 ~ 36V<br>60 ~ 72V|||| ||**OVER TEMPERATURE**|Protection type :Shut down O/P voltage, recovers automatically after temperature goes down|||| ||**OUTPUT VOLTAGE**<br>**PROGRAMMABLE(PV)Note.5,6**|Adjustment of output voltage is allowable to 50 ~ 120% of nominal output voltage. Please refer to the Function Manual.|||| ||**OUTPUT CURRENT**<br>**PROGRAMMABLE(PC) Note.6**|Adjustment of constant current level is allowable to 20 ~ 100% of rated current. Please refer to the Function Manual.|||| ||**REMOTE ON/OFF CONTROL**|Power ON : Short circuit Power OFF : Open circuit|||| ||**AUXILIARY POWER**|12V@0.5A tolerance 10%, ripple 150mVp-p<br>±|||| ||**DC-OK SIGNAL**|The TTL signal out, PSU turn on = -0.5 ~ 0.5V ; PSU turn off = 3.5 ~ 5.5V. Please refer to the Function Manual.|||| ||**WORKING TEMP.**|-30 ~ +70<br>Baseplate temperature (Refer to “Derating Curve")<br>℃|||| ||**WORKING HUMIDITY**|20 ~ 90% RH non-condensing|||| ||**STORAGE TEMP., HUMIDITY**|-40 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃|||| ||**TEMP. COEFFICIENT**|±<br>℃<br>℃)<br>0.03%/<br>(0 ~ 50|||| ||**VIBRATION**|10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes|||| ||**OVER VOLTAGE CATEGORY**|Ⅱ; According to EN61558; altitude up to 5000 meters.|||| ||**SAFETY STANDARDS**|UL62368-1, CAN/CSA C22.2<br>,TUV EN62368-1,<br>approved ; design refers to EN61558-1, EN60335-1<br>No. 62368-1<br>EAC TP TC 004|||| ||**WITHSTAND VOLTAGE**|I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC|||| ||**ISOLATION RESISTANCE**<br>**MTBF**<br>**EMC IMMUNITY**<br>**EMC EMISSION**|I/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25<br>/ 70%RH<br>℃|||| |||**Parameter**|**Standard**||**Test Level / Note**| |||Conducted|EN55032 (CISPR32)||Class B| |||Radiated|EN55032 (CISPR32)||Class A| |||Harmonic Current|EN61000-3-12||-----| |||Voltage Flicker|EN61000-3-3||-----| |||**Parameter**|**Standard**||**Test Level / Note**| |||ESD|EN61000-4-2||Level 3, 8KV air ; Level 2, 4KV contact| |||Radiated|EN61000-4-3||Level 3| |||EFT / Burst|EN61000-4-4||Level 3| |||Surge|EN61000-6-2||2KV/Line-Line 4KV/Line-Earth| |||Conducted|EN61000-4-6||Level 3| |||Magnetic Field|EN61000-4-8||Level 4| |||Voltage Dips and Interruptions|EN61000-4-11||>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods| |||183.4K hrs min.<br>Telcordia SR-332 (Bellcore) ; 56.26K hrs min. MIL-HDBK-217F (25<br>)<br>℃|||| ||**DIMENSION**|380*141.4*60mm (L*W*H)|||| ||℃<br>ncludes set up tolerance,<br>derating curve<br>℃<br>℃<br>4.5Kg;4pcs/19Kg/2.46CUFT<br>**PACKING**<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25 _of ambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance<br>line regulation and load regulation.<br>4. Derating may be needed under low input voltages. Please check the<br>for more details.<br>5. Without water or fan cooling to provide adequate heat dissipation, OTP might be triggered if trimming output voltage by PV signal toward upper or bottom<br>limits of nominal voltage. Under such condition, enhanced cooling on PSU is highly recommended.<br>6. PV/PC function when users are not operating on PMBus. SVR functions when users are neither operation on PMBus nor using PV/PC.<br>7. Need additional EMI filter to meet regulations of EMC conducted and radiated emission. Characteristics of EMI filter please refer to the table, Minimum<br>Insertion Loss.<br>8. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a 600mm*900mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http:/Avww.meanwell.com)<br>9. The ambient temperature derating of 3.5<br>/1000m with fanless models and of 5<br>+ /1000m with fan models for operating altitude higherthan 2000m(6500ft).<br>10. The efficiency is measured at75% load.||||| ncludes set up tolerance, derating curve > ℃ /1000m with fanless models and of 5 ℃ + /1000m with fan models for operating altitude higher than 2000m(6500ft). _File Name:PHP-3500-SPEC 2020-03-27_ ## **-** 3500W Conduction Cooling with PFC Switching Supply **PHP 3500 series** **==> picture [511 x 668] intentionally omitted <==** **----- Start of picture text -----**<br> BLOCK DIAGRAM<br>PFC fosc : 110KHz<br>PWM fosc : 100KHz<br>I/P FILTEREMI CURRENTLIMITINGINRUSHACTIVE RECTIFIERSPFC& SWITCHINGPOWER RECTIFIERSFILTER& +V-V<br>DETECTION<br>CIRCUIT<br>O.L.P.<br>DETECTION MCU O.V.P. PV/PC<br>CIRCUIT<br>O.T.P. TRANSCEIVERS DA/DB<br>O.T.P. MCU ISOLATIONDATA T-AlarmDC-OK<br>(SDA/SCL)<br>AUX (CANH/CANL)<br>POWER<br>RECTIFIERS Remote ON-OFF<br>& 12V/0.5A<br>FILTER<br>DERATING CURVE<br>100 100<br>75 230VAC<br>65 Input only<br>60 60<br>50 50<br>230VAC<br>Input only<br>30<br>20<br>-30 -25 0 25 45 70 (HORIZONTAL) -30 -25 0 25 45 50 70 (HORIZONTAL)<br>AMBIENT TEMPERATURE WITH ADDITIONAL ALUMINUM PLATE( ℃ ) AMBIENT TEMPERATURE WITH 128 CFM FAN*2 OR WATER<br>(450x450x3mm) COOLING SYSTEM ( ℃ )<br>Note. Tcase max. ≦ 70oC and ambient temp must be within above Note. Tcase max. ≦ 45oC and ambient temp must be within above<br>de-rating curve. de-rating curve.<br>STATIC CHARACTERISTICS<br>100<br>100<br>230VAC<br>Input only<br>50<br>50<br>20<br>-30 -25 0 25 45 50 70 (HORIZONTAL) 90 100 115 180 264<br>AMBIENT TEMPERATURE WITHOUT ALUMINUM PLATE( ℃ ) INPUT VOLTAGE (VAC) 60Hz<br>LOAD (%) LOAD (%)<br>LOAD (%) LOAD (%)<br>**----- End of picture text -----**<br> _File Name:PHP-3500-SPEC 2020-03-27_ ## **-** 3500W Conduction Cooling with PFC Switching Supply **PHP 3500 series** ## **FUNCTION MANUAL** **1.Output Voltage Programming (or, PV / remote voltage programming / remote adjust / margin programming / dynamic voltage trim)** ※ In addition to the adjustment via the built-in potentiometer, the output voltage can be trimmed by applying EXTERNAL VOLTAGE. **==> picture [462 x 229] intentionally omitted <==** **----- Start of picture text -----**<br> CN55<br>PIN1 -V(Signal)<br>EXTERNAL<br>VOLTAGE (DC)<br>PIN5 PV<br>Vout<br>120<br>100<br>100<br>Non-Linear 80<br>60<br>50<br>40<br>20<br>V<br>0 0.4 1 4.74.8 50 90 95 100 120<br>OUTPUT VOLTAGE (%)<br>◎ The rated current should change with the Output Voltage Programming accordingly.<br>OUTPUT VOLTAGE(%)<br>OUTPUT CURRENT (%)<br>**----- End of picture text -----**<br> ## **2.Output Current Programming (or, PC / remote current programming / dynamic current trim)** ※ The output current can be trimmed to 20~100% of the rated current by applying EXTERNAL VOLTAGE. **==> picture [466 x 112] intentionally omitted <==** **----- Start of picture text -----**<br> CN55<br>PIN1 -V(Signal)<br>EXTERNAL<br>VOLTAGE (DC)<br>PIN3 PC<br>※ Covered by over temperature protection, auto de-rating function works under operation either in PC mode or under control by communication protocol.<br>T1(Typ.): Maximum ambient temperature of full load.<br>T2(Typ.): T1+5℃.<br>**----- End of picture text -----**<br> **==> picture [469 x 146] intentionally omitted <==** **----- Start of picture text -----**<br> Iout<br>110 100<br>100<br>80 Non-Linear<br>Non-Linear<br>60<br>50<br>40<br>20 20<br>V<br>0 0.4 1 4.7 4.8 T1 T2 (HORIZONTAL)<br>EXTERNAL VOLTAGE (DC) AMBIENT TEMPERATURE ( ℃ )<br>LOAD (%)<br>OUTPUT CURRENT(%)<br>**----- End of picture text -----**<br> _File Name:PHP-3500-SPEC 2020-03-27_ ## **-** 3500W Conduction Cooling with PFC Switching Supply **PHP 3500 series** ## **3.Remote ON-OFF Control** The power supply can be turned ON/OFF individually or along with other units in parallel by using the "Remote ON-OFF" function. **==> picture [379 x 96] intentionally omitted <==** **----- Start of picture text -----**<br> CN47<br>Remote ON-OFF Power Supply Status<br>Short circuit ON<br>PIN1 +12V-AUX Open circuit OFF<br>Switch<br>PIN3-Remote ON-OFF<br>**----- End of picture text -----**<br> ## **4.DC-OK Signal** DC-OK signal is a TTL level signal. The maximum sourcing current is 10mA and the maximum external voltage is 5.6V. **==> picture [376 x 97] intentionally omitted <==** **----- Start of picture text -----**<br> CN47<br>DC-OK signal Power Supply Status<br>“High” >3.5~5.5V OFF<br>“Low” <-0.5~0.5V ON<br>PIN5-DC-OK Signal<br>PIN4-GND-AUX<br>**----- End of picture text -----**<br> ## **5.PMBus Communication Interface** PHP-3500 supports PMBus Rev. 1.1 with maximum 100KHz bus speed, allowing information reading, status monitoring, output trimming, etc. For details, please refer to the Function Manual. _File Name:PHP-3500-SPEC 2020-03-27_ ## **-** 3500W Conduction Cooling with PFC Switching Supply **PHP 3500 series** ## **6.Current Sharing** PHP-3500 has the built-in active current sharing function and can be connected in parallel, up to 4 units, to provide higher output power as exhibited below : ※ The power supplies should be paralleled using short and large diameter wiring and then connected to the load. ※ Difference of output voltages among parallel units should be less than 0.2V. - ※ The total output current must not exceed the value determined by the following equation: Maximum output current at parallel operation=(Rated current per unit)×(Number of unit)×0.9 - ※ When the total output current is less than 5% of the total rated current, or say (5% of Rated current per unit)×(Number of unit) the current shared among units may not be balanced. - ※ Under parallel operation ripple of the output voltage may be higher than the SPEC at light load condition. It will go back to normal ripple level once the output load is more than 5%. - ※ CN55/SW51 Function pin connection |Paralle<br>1 unit<br>2 unit<br>3 unit<br>4 unit|l<br>CN55<br>SW51<br>PSU1|l<br>CN55<br>SW51<br>PSU1|PSU2|PSU2|PSU3|PSU3|PSU4|PSU4| |---|---|---|---|---|---|---|---|---| |||SW51|CN5<br>|5<br>SW51|CN55|SW51|CN55|SW51| ||X|ON|∣|∣|∣|∣|∣|∣| ||V|ON|V|ON|∣|∣|∣|∣| ||V|ON|V|OFF|V|ON|∣|∣| ||V|ON|V|OFF|V|OFF|V|ON| - (V : CN55 connected ; X : CN55 not connected.) **==> picture [382 x 260] intentionally omitted <==** **----- Start of picture text -----**<br> PHP-3500 PHP-3500 PHP-3500 PHP-3500<br>PSU1 PSU2 PSU3 PSU4<br>TB1 TB1 TB1 TB1<br>-V +V -V +V -V +V -V +V<br>-V +V<br>LOAD<br>Fig 6.1<br>1 13 15 1 13 15 1 13 15 1 13 15<br>-V(signal) DB DA -V(signal) DB DA -V(signal) DB DA -V(signal) DB DA<br>+V(signal) DB DA +V(signal) DB DA +V(signal) DB DA +V(signal) DB DA<br>2 14 16 2 14 16 2 14 16 2 14 16<br>PSU1 CN55 PSU4 CN55<br>PSU2 CN55 PSU3 CN55<br>**----- End of picture text -----**<br> If the lines of CN55 are too long, they should be twisted in pairs to avoid the noise. ◎ DA,DB and -V(signal) are connected mutually in parallel. _File Name:PHP-3500-SPEC 2020-03-27_ **-** 3500W Conduction Cooling with PFC Switching Supply **PHP 3500 series** **==> picture [500 x 757] intentionally omitted <==** **----- Start of picture text -----**<br> MECHANICAL SPECIFICATION Case No.278A Unit:mm<br>tc T case<br>380<br>369 5.5<br>154<br>-V<br>+V<br>CN47<br>LED SVR<br>CN55<br>TB1<br>3<br>2<br>1<br>6-ψ5.2 L=12<br>183<br>�tc : Max. Case Temperature tc T case<br>AC Input Terminal(TB1) Pin NO. Assignment ※DC Output Terminal Pin No. Assignment<br>Pin No. Assignment Terminal Max mounting torque Assignment Diagram Maximum mounting torque<br>1 AC/L<br>DECA<br>2 AC/N T25-EM10-03 18Kgf-cm +V, -V 10Kgf-cm<br>3<br>※ LED Status Indicators<br>LED Description<br>Green The power supply functions normally.<br>Red (Flashing) The LED will flash with red light when internal temperature reaches 85℃; under this<br>condition, the unit still operates normally without entering OTP.<br>(In the meantime, an alarm signal will be sent out through the PMBus /CANBus interface.)<br>Red Abnormal status (Over temperature protection, Overload protection)<br>※Control Pin No. Assignment(CN55) : HRS DF11-22DP-2DS or equivalent<br>2 1 Mating Housing HRS DF11-22DS or equivalent<br>Terminal HRS DF11-**SC or equivalent<br>22 21<br>Pin No. Function Description<br>1 -V (Signal) Negative output voltage signal.<br>2 +V (Signal) Positive output voltage signal.<br>3,4 PC Connection for constant current level programming. (Note.1)<br>5,6 PV Connection for output voltage programming. (Note.1)<br>7,8,9,10,11,12 NC<br>13,14,15,16 DB,DA Differential digital signal for parallel control. (Note.1)<br>17,18 GND-AUX(S) The signal return is isolated from the output terminals (+V & -V).<br>SCL For PMBus model: Serial Clock used in the PMBus interface. (Note.2)<br>19,20<br>CANL For CANBus model: Data line used in CANBus interface. (Note.2)<br>SDA For PMBus model: Serial Data used in the PMBus interface. (Note.2)<br>21,22<br>CANH For CANBus model: Data line used in CANBus interface. (Note.2)<br>Note1: Non-isolated signal, referenced to [-V(signal)].<br>Note2: Isolated signal, referenced to GND-AUX(S).<br>8.2<br>125 141.4<br>7<br>10<br>60<br>6 2<br>22 5 21<br>SW51 21 1<br>22 2<br>OFF ON 21 1<br>**----- End of picture text -----**<br> _File Name:PHP-3500-SPEC 2020-03-27_ ## **-** 3500W Conduction Cooling with PFC Switching Supply **PHP 3500 series** **==> picture [455 x 556] intentionally omitted <==** **----- Start of picture text -----**<br> ※Control Pin No. Assignment(CN47) : HRS DF11-06DP-2DS or equivalent<br>2 1<br>Mating Housing HRS DF11-06DS or equivalent<br>6 5 Terminal HRS DF11-**SC or equivalent<br>Pin No. Function Description<br>1 +12V-AUX Auxiliary voltage output, 10.8~13.2V, referenced to GND-AUX (pin 2) .<br>The maximum load current is 0.5A. This output has the built-in "Oring diodes" and is not controlled by the Remote ON/OFF control.<br>2 GND-AUX Auxiliary voltage output GND. The signal return is isolated from the output terminals (+V & -V).<br>3 Remote The unit can turn the output ON/OFF by electrical signal or dry contact between Remote ON/OFF and +12V-AUX . (Note.2)<br>ON-OFF Short (10.8 ~ 13.2V) : Power ON ; Open (-0.5 ~ 0.5V) : Power OFF ; The maximum input voltage is 13.2V.<br>4 GND-AUX(S) The signal return is isolated from the output terminals (+V & -V).<br>High (3.5 ~ 5.5V) : When the Vout ≦80%±5%.<br>5 DC-OK Low (-0.5 ~ 0.5V) : When Vout ≧80%±5%.<br>The maximum sourcing current is 10mA and only for output. (Note.2)<br>High (3.5 ~ 5.5V) : When the internal temperature exceeds the limit of temperature alarm.<br>6 T-ALARM Low (-0.5 ~ 0.5V) : When the internal temperature is normal, and when fan works normally.<br>The maximum sourcing current is 10mA and only for output(Note.2)<br>GUIDANCE OF ADDITIONAL FILTER<br>1.Schematic<br>1 3<br>Cy<br>LINE Cx L Cx R L LOAD<br>Cy<br>2 4<br>5<br>2.Minimum insertion loss (In dB at 50 Ω system)<br>FREQ. MHz 0.01 0.05 0.10 0.15 0.50 1.0 5.0 10 30<br>COM. MODE dB 2 5 8 10 30 35 55 45 30<br>DIF. MODE dB 4 15 18 18 45 50 40 40 40<br>3.Configration<br>PHP-3500<br>EMI AC DC<br>LOAD<br>FILTER I/P O/P<br>AC Utility<br>**----- End of picture text -----**<br> _File Name:PHP-3500-SPEC 2020-03-27_ ## **-** 3500W Conduction Cooling with PFC Switching Supply **PHP 3500 series** ## **1.Operate with additional aluminum plate** In order to meet the“Derating Curve”and the “Static Characteristics” ,PHP-3500 series must be installed onto an aluminum plate(or the cabinet of the same size) on the bottom.The size of the suggested aluminum plate is shown as below. And for optimizing thermal performance, the aluminum plate must have an even and smooth surface (or coated with thermal grease), and PHP-3500 series must be firmly mounted at the center of the aluminum plate. **==> picture [501 x 563] intentionally omitted <==** **----- Start of picture text -----**<br> unit:mm<br>M5*6<br>2.Suitable for conduction cooling<br>Inlet temperature��25℃<br>Flow rate (minimum)� 1 LPM<br>If optional cold plate is in need, please contact MEAN WELL for details.<br>Ordering No.: HS-656<br>380<br>374.5<br>364.5<br>183<br>15.5<br>5.5 50 2-3/8"(ψ9.5)<br>M4*6 Water Output Apply thermal grease (gap filler) between power supply<br>28.5 and cold plate connection surface.<br>Thermal grease (gap filler) :<br>* Thermal conductivity is no less than 1W/mK.<br>* Thickness is no more than 0.3mm.<br>5.5 M5*6 Water Input<br>15.5<br>12<br>159.5<br>364.5<br>374.5<br>450<br>450<br>7.7 7.1 16.08<br>140.4 132.7 108.25<br>70.2<br>7.1<br>3<br>**----- End of picture text -----**<br> _File Name:PHP-3500-SPEC 2020-03-27_ ## **-** 3500W Conduction Cooling with PFC Switching Supply **PHP 3500 series** **==> picture [17 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> M5*6<br>**----- End of picture text -----**<br> **==> picture [80 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> 3.With 128CFM forced air<br>**----- End of picture text -----**<br> **==> picture [266 x 61] intentionally omitted <==** **----- Start of picture text -----**<br> 190mm<br>128CFM x 2<br>FAN FAN<br>Air flow<br>direction<br>100mm<br>**----- End of picture text -----**<br> _File Name:PHP-3500-SPEC 2020-03-27_
Updated at June 6, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →