PDRC-75-24-2
AC/DC DIN Rail Power Supply (PSU), ITE, 1 Output, 91 W, 24 VDC, 3.8 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: CUI
- Product type:
- SVHC: To Be Advised
- Product Range: PDRC-75 Series
- No. of Outputs: 1 Output
- Output Power Max: 91W
- Current, Output 4: -
- Input Voltage VAC: 90V AC to 264V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 3.8A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 24VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 96.8 € |
| Current stock | 10+ |
| Lead time | 30 days |
Additional Resources: Product Page ~~OS~~ | 3D Model **date** 08/04/2020 **page** 1 of 6 ## **SERIES:** PDRC-75 **DESCRIPTION:** AC-DC DIN RAIL POWER SUPPLY **│** ## **FEATURES** - low profile for building automation - universal input (90~264 Vac) - integrated fuse and surge protection - 3,000 Vac input/output isolation voltage - DC On/Low LED indicators - over-voltage/current protection - UL/cUL, TUV, CE certified |**MODEL**|**output**<br>**voltage**|**output**<br>**current**|**output**<br>**power**|**ripple**<br>**and noise1**|**efficiency2**| |---|---|---|---|---|---| |||**max**|**max**|**max**|**typ**| ||(Vdc)|(A)|(W)|(mVp-p)|**(%)**| |PDRC-75-5|5|12.0|60|50|80| |PDRC-75-12|12|6.0|72|50|86| |PDRC-75-15|15|5.0|75|50|86| |PDRC-75-24|24|4.2|100|50|89| |PDRC-75-24-23|24|3.8|91|50|89| Notes: 1. At full load, nominal input, 20 MHz bandwidth oscilloscope. 2. At nominal input. 3. Model PDRC-75-24-2 is UL 1310 certified. 4. All specifications are measured at Ta=25°C, nominal input voltage, and rated output load unless otherwise specified. ## **PART NUMBER KEY** ## **- - PDRC 75 XX** Base Number Output Voltage **cui** .com Additional Resources: Product Page | 3D Model **CUI Inc │ SERIES:** PDRC-75 **│ DESCRIPTION:** AC-DC DIN RAIL POWER SUPPLY **date** 08/04/2020 **│ page** 2 of 6 |**INPUT**|| |---|---| |**parameter**|**conditions/description**<br>**min**<br>**typ**<br>**max**<br>**units**| |voltage|90<br>120<br>264<br>375<br>Vac<br>Vdc| |frequency|47<br>63<br>Hz| |current|at 90 Vac, full load<br>5 Vdc output model<br>12, 15 output model<br>24 Vdc output model<br>1.5<br>1.7<br>2.2<br>A<br>A<br>A| |inrush current|at 115 Vac, full load<br>at 230 Vac, full load<br>30<br>60<br>A<br>A| |leakage current|input to output<br>0.25<br>mA| |**OUTPUT**|| |**parameter**|**conditions/description**<br>**min**<br>**typ**<br>**max**<br>**units**| |capacitive load|at Vi nom, full load<br>3,500<br>µF| |initial set point accuracy|±1<br>%| |line regulation|at full load, V in min to V in max<br>±1<br>%| |load regulation|at Vi nom, 0~100% load<br>±1<br>%| |adjustability|via built in trim pot, 0.8 A load<br>5 Vdc output model<br>12 Vdc output model<br>15 Vdc output model<br>24 Vdc output model<br>24 Vdc output model (PDRC-75-24-2)<br>5<br>12<br>13.5<br>24<br>20<br>5.5<br>14<br>16.5<br>28<br>24.2<br>Vdc<br>Vdc<br>Vdc<br>Vdc<br>Vdc| |rated continuous loading at<br>max trim voltage|5 Vdc output model (5.5 Vdc)<br>12 Vdc output model (14.0 Vdc)<br>15 Vdc output model (16.5 Vdc)<br>24 Vdc output model (28.0 Vdc)<br>24 Vdc output model (PDRC-75-24-2) (24.2 Vdc)<br>10.5<br>5.1<br>4.5<br>3.6<br>3.7<br>A<br>A<br>A<br>A<br>A| |start-up time|at Vi nom, full load<br>at Vi nom, full load with max capacitive load<br>1.0<br>1.5<br>s<br>s| |rise time|at Vi nom, full load<br>at Vi nom, full load with max capacitive load<br>150<br>500<br>ms<br>ms| |hold-up time|5, 12 Vdc output models<br>at 115 Vac, full load<br>at 230 Vac, full load<br>16<br>60<br>ms<br>ms| ||15, 24 Vdc output models<br>at 115 Vac, full load<br>at 230 Vac, full load<br>12<br>60<br>ms<br>ms| |fall time|at Vi nom, full load<br>150<br>ms| |transient recovery time|at Vi nom, 100~50% load<br>2<br>ms| |switching frequency|at Vi nom, full load<br>35<br>45<br>kHz| |temperature coefcient|±0.03<br>%/°C| |power back immunity|at Vi nom, full load, for 1 second<br>5 Vdc output model<br>12 Vdc output model<br>15 Vdc output model<br>24 Vdc output model<br>7.5<br>18<br>22<br>35<br>Vdc<br>Vdc<br>Vdc<br>Vdc| |DC ON indicator threshold at<br>start-up (GREEN)|5 Vdc output model<br>12 Vdc output model<br>15 Vdc output model<br>24 Vdc output model<br>3.5<br>9.0<br>11.0<br>19.2<br>4.5<br>10.8<br>13.5<br>21.6<br>Vdc<br>Vdc<br>Vdc<br>Vdc| |DC LOW indicator threshold<br>after start-up (RED)|5 Vdc output model<br>12 Vdc output model<br>15 Vdc output model<br>24 Vdc output model<br>3.5<br>9.0<br>11.0<br>19.2<br>4.5<br>10.8<br>13.5<br>21.6<br>Vdc<br>Vdc<br>Vdc<br>Vdc| **cui** .com Additional Resources: Product Page | 3D Model **CUI Inc │ SERIES:** PDRC-75 **│ DESCRIPTION:** AC-DC DIN RAIL POWER SUPPLY **date** 08/04/2020 **│ page** 3 of 6 |**PROTECTIONS**|||||| |---|---|---|---|---|---| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| ||at Vi nom, full load, auto recovery||||| ||5 Vdc output model|5.75||6.5|Vdc| |over voltage protection|12 Vdc output model<br>15 Vdc output model|15<br>18||16.5<br>20|Vdc<br>Vdc| ||24 Vdc output model|30||33|Vdc| ||24 Vdc output model (PDRC-75-24-2)|24.5||25.5|Vdc| ||fold forward (see curve)||||| |over current protection|24 Vdc output model (PDRC-75-24-2)|102||108|%| ||all other models|110||150|%| |short circuit protection|fold forward||||| |**SAFETY & COMPLIANCE**|||||| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |isolation voltage|input to output for 1 minute|3,000<br>4,242|||Vac<br>Vdc| |isolation resistance|input to output at 500 Vdc|100|||MΩ| |safety approvals5|UL 508, UL 1310, UL/EN 62368-1<br>ISA 12.12.01 (Class I, Div 2, Groups A~D)||||| |safety class|class I||||| ||EN 55032 Class B, EN 55024, ENV 50204,||||| ||EN 61204-3, EN 61000-3-2, EN 61000-3-3,||||| |EMI/EMC|EN 61000-6-2, EN 61000-6-3, EN 61000-4-2,||||| ||EN 61000-4-3, EN 61000-4-4, EN 61000-4-5,||||| ||EN 61000-4-6, EN 61000-4-8, EN 61000-4-11||||| |pollution degree|2||||| |degree of protection|IP20||||| ||as per Bellcore Issue 6 at 40 °C, GB||||| ||5 Vdc output model||610,000||hours| |MTBF|12 Vdc output model<br>15 Vdc output model||578,000<br>581,000||hours<br>hours| ||24 Vdc output model||554,000||hours| ||24 Vdc output model (PDRC-75-24-2)||583,000||hours| |RoHS|yes||||| Notes: 5. Model PDRC-75-24-2 is only model that is UL 1310 certified. 6. The power supply is considered a component which will be installed into final equipment. The final equipment still must be tested to meet the necessary EMC directives. ## **ENVIRONMENTAL** |**ENVIRONMENTAL**|||||| |---|---|---|---|---|---| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |operating temperature|see derating curves|-40||71|°C| |storage temperature||-40||85|°C| |humidity|non-condensing|20||95|%| |altitude|IEC 60068-2-13|||4,850|m| ||meets IEC 60068-2-6 (Mounting on rail: 10~500||||| |vibration|Hz, 2 G, along X,Y,Z axis, for 60 minutes on each||||| ||axis)||||| |shock|meets IEC 60068-2-27 (15 G, 11 ms, 3 axis, 6<br>faces, 3 times for each face)||||| **cui** .com Additional Resources: Product Page | 3D Model **CUI Inc │ SERIES:** PDRC-75 **│ DESCRIPTION:** AC-DC DIN RAIL POWER SUPPLY **date** 08/04/2020 **│ page** 4 of 6 ## **MECHANICAL** |**MECHANICAL**|||||| |---|---|---|---|---|---| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |dimensions|91.00 x 90.00 x 57.00 (3.58 x 3.54 x 2.24 inches)||||mm| |material|plastic||||| |weight|||380||g| |cooling|natural convection||||| |input/output connector|accepts 24~12 AWG wire||||| ## **MECHANICAL DRAWING** units: mm [inch] tolerance: X≤30.00: ±0.30 [±0.01] 30.00<X≤120.00: ±0.50 [±0.02] unless otherwise noted ||| |---|---| |TERMINAL<br>CONNECTIONS|| |TERMINAL|Function| |1|V-| |2<br>3|V-<br>V+| |4|<br>V+| |5|L| |6|N| **==> picture [374 x 242] intentionally omitted <==** ||INSTALLATION| |---|---| |DIN RAIL|TS35/7.5 or TS35/15| |Cable|fexible/solid, copper conductors<br>only, 60/75°C| |Wire Range|24~12 AWG<br>(0.2~2.5 mm2)| |Strip Length|7 mm| |Screw Torque|6 lb·in| |Position|Vertical| |Cooling|Natural convection, 25 mm<br>clearance on all sides| **cui** .com Additional Resources: Product Page | 3D Model **CUI Inc │ SERIES:** PDRC-75 **│ DESCRIPTION:** AC-DC DIN RAIL POWER SUPPLY **date** 08/04/2020 **│ page** 5 of 6 ## **DERATING CURVES** **==> picture [344 x 188] intentionally omitted <==** **----- Start of picture text -----**<br> Temperature Derating Curve<br>(Output Load vs. Ambient Tempearature)<br>100 5 Vdc output model<br>all other models<br>80<br>75<br>62.5<br>40<br>20<br>-40 0 20 30 40 56 61 71 80<br>Ambient Temperature (°C)<br>Load (%)<br>**----- End of picture text -----**<br> ## **EFFICIENCY CURVES** **==> picture [201 x 168] intentionally omitted <==** **----- Start of picture text -----**<br> PDRC-75-24 Efficiency Curve<br>(Efficiency vs. Load Current)<br>Load Current (%)<br>Efficiency (%)<br>**----- End of picture text -----**<br> ## **CURRENT LIMITED CURVE** PDRC-75-24 Typical Over Current Protection Curve (Output Voltage vs. Time) **==> picture [281 x 84] intentionally omitted <==** **----- Start of picture text -----**<br> (%)<br> (%)<br>**----- End of picture text -----**<br> **cui** .com Additional Resources: Product Page | 3D Model **CUI Inc │ SERIES:** PDRC-75 **│ DESCRIPTION:** AC-DC DIN RAIL POWER SUPPLY **date** 08/04/2020 **│ page** 6 of 6 ## **REVISION HISTORY** |**rev.**|**description**|**date**| |---|---|---| |1.0|initial release|06/17/2019| |1.01|updated safetycertifcations|08/04/2020| The revision history provided is for informational purposes only and is believed to be accurate. **==> picture [115 x 37] intentionally omitted <==** **Headquarters** 20050 SW 112th Ave. Tualatin, OR 97062 **800.275.4899** Fax 503.612.2383 **cui** .com techsupport@cui.com CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →