Image not available
Illustrative purposes only
PDA150F-12-N
AC/DC Enclosed Power Supply (PSU), ITE, 1 Outputs, 156 W, 12 VDC, 13 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: COSEL
- Product type: AC / DC Enclosed Power Supplies
- SVHC: Lead (04-Feb-2026)
- Product Range: PDA Series
- No. of Outputs: 1Outputs
- Output Power Max: 156W
- Current, Output 4: -
- Input Voltage VAC: 85V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 13A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 12VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 61.19 € |
| Current stock | 10+ |
| Lead time | 30 days |
**AC-DC Power Supplies Enclosed Type**
Power World wide Safety EMI Inrush OCP Factor Approvals current Correction limiting
OVP
Remote Parallel ON/OFF Operation
## **PDA-series**
## ~~|a~~ **Feature CE marking**
High efficiency
Low Voltage Directive RoHS Directive
Low noise
Complies with SEMI F47 Harmonic attenuator (Complies with IEC61000-3-2)
## **UKCA marking**
## a
Universal input (85-264VAC)
Electrical Equipment Safety Regulations RoHS Regulations
Built-in inrush current, overcurrent and overvoltage protection circuits
UL508 (Optional)
## **EMI**
## ~~a~~ **EMI**
· PDA300F/600F
Parallel Operation / N+1 Parallel Redundancy Operation possible With various alarms
Complies with CISPR11-B, CISPR32-B, EN55011-B, EN55032-B, FCC Part 15-B, FCC Part 18-B, VCCI-B
With AUX output 12V Output voltage can be varied to near 0V
## ~~a~~ **EMS Compliance** : EN61204-3, EN61000-6-2
EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 EN61000-4-8 EN61000-4-11
## ~~a~~ **Safety agency approvals**
UL62368-1, C-UL (equivalent to CAN/CSA-C22.2 No.62368-1), EN62368-1
Complies with DEN-AN UL508 (Optional)
## ~~a~~ **5-year warranty (refer to Instruction Manual)**
**PDA-1**
January 29, 2026
**AC-DC Power Supplies Enclosed Type PD PDA15F** ~~ed] —~~ 1
**AC-DC Power Supplies Enclosed Type Ordering information - - PD A 15 F** O O **PDA15F** ~~] —~~ 1 2 3 4 5 6
**==> picture [2 x 3] intentionally omitted <==**
**----- Start of picture text -----**<br>
R<br>**----- End of picture text -----**<br>
**Example recommended EMI/EMC filter NAC-06-472** High voltage pulse noise type : NAP series Low leakage current type : NAM series *A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply.
1Series name 2Single output 3Output wattage 4Universal input 5Output voltage 6Optional[*][1] N : with cover C: with Coating G: LOW leakage current J1 : VH(J.S.T.) connector type N1 : with DIN rail and Cover T5 : UL508[5V,12V,24V]
For option details, refer to Instruction Manual 8.1.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
||**MODEL**<br>~~a~~|**MODEL**<br>~~a~~|**PDA15F-3R3**|**PDA15F-5**|**PDA15F-12**|**PDA15F-15**|**PDA15F-24**|
|---|---|---|---|---|---|---|---|
|**INPUT**<br>~~|~~|**VOLTAGE[VAC]**<br>*2 <br>~~Po~~||85 - 264 1f(Refer to “Derating” and Instruction Manual 1.1)|||||
||**CURRENT[A]**<br>~~a~~|**ACIN 100V**<br>~~a~~|0.24typ<br>~~a~~|0.35typ||||
|||**ACIN 230V**<br>~~a~~<br>~~a~~|0.13typ<br>~~a~~|0.19typ||||
||**FREQUENCY[Hz]**<br>~~Po~~||50 / 60(45 - 440)|||||
||**EFFICIENCY[%]**<br>~~EE~~|**ACIN 100V**<br>~~EE~~|72.0typ<br>~~EE~~|75.0typ<br>~~EE~~|78.5typ<br>~~EE~~|80.5typ<br>~~EE~~|81.0typ|
|||**ACIN 230V**<br>~~EE~~<br>~~a a~~|73.0typ<br>~~EE~~<br>~~a~~|78.5typ<br>~~EE~~|81.5typ<br>~~EE~~|82.5typ<br>~~EE~~|83.5typ|
||**INRUSH CURRENT[A]**<br>~~ES~~<br>~~|~~<br>~~|~~<br>~~tC~~|**ACIN 100V**<br>~~ES~~<br>~~|~~|15typ (Io=100%)at cold start|||||
|||**ACIN 230V**<br>~~ES~~<br>~~||~~|35typ (Io=100%)at cold start|||||
||**LEAKAGE CURRENT[mA]**<br>~~ES~~<br>~~||~~<br>~~|~~<br>~~tC~~<br>:~—“‘“CSC:*sSCsCY||0.15 / 0.30max(ACIN 100V / 240V,60Hz,Io=100%,Accordingto IEC62368-1,and DEN-AN)|||||
|**OUTPUT**<br>~~|~~|**VOLTAGE[V]**<br>~~|~~<br>~~|~~<br>~~tC~~<br>~~a~~<br>~~a~~||3.3|5<br>~~I (~~|12<br>~~(~~|15|24|
||**CURRENT[A]**<br>*2 <br>~~a~~<br>~~a~~||3.0|3.0<br>~~I (~~|1.3<br>~~(~~|1.0|0.7|
||**LINE REGULATION[mV]**<br>*3 <br>~~a~~||20max|20max<br>~~I (~~|48max<br>~~(~~|60max|96max|
||**LOAD REGULATION[mV]**<br>*3 <br>~~a~~||40max<br>~~a~~|40max|100max|120max|150max|
||**RIPPLE[mVp-p]**<br>*4<br>~~a~~|**0 to +55**C <br>~~a~~|80max<br>~~a~~|80max|120max|120max|120max|
|||**-20 to 0**C<br>~~a~~<br>~~a~~|140max<br>~~a~~|140max|160max|160max|160max|
|||**Io=0 to 15%** <br>~~a~~<br>~~a~~|300max<br>~~a~~|300max|300max|360max|300max|
||**RIPPLE NOISE[mVp-p]**<br>*4<br>~~a~~|**0 to +55**C <br>~~**a**~~|120max|120max|150max|150max|150max|
|||**-20 to 0**C<br>~~**a**~~|160max|160max|180max|180max|180max|
|||**Io=0 to 15%** <br>~~**a**~~|360max|360max|360max|360max|360max|
||**TEMPERATURE REGULATION[mV]**<br>~~a~~|**0 to +55**C <br>~~a~~|50max|50max|120max|150max|240max|
|||**-20 to +55**C <br>~~a~~<br>~~a~~|60max|60max|150max|180max|290max|
||**DRIFT[mV]**<br>*5 <br>~~a~~||20max|20max|48max|60max|96max|
||**START-UP TIME[ms]**<br>~~Po~~||80typ (ACIN 100V,Io=100%)|||||
||**HOLD-UP TIME[ms]**<br>~~Po~~||20typ (ACIN 100V,Io=100%)/ 150typ (ACIN 230V,Io=100%)|||||
||**OUTPUT VOLTAGE ADJUSTMENT RANGE[V]**<br>~~a~~||2.85 to 3.60|4.50 to 5.50|10.00 to 13.20|13.20 to 18.00|19.20 to 27.00|
||**OUTPUT VOLTAGE SETTING[V]**<br>~~QO~~||3.30 to 3.40<br>~~QO~~|5.00 to 5.15<br>~~QO~~|12.00 to 12.48<br>~~QO~~|15.00 to 15.60<br>~~QO~~|24.00 to 24.96|
|**PROTECTION**<br>**CIRCUIT AND**<br>**OTHERS**<br>~~|~~|**OVERCURRENT PROTECTION**<br>~~Po~~||Works over 105% of ratingand recovers automatically|||||
||**OVERVOLTAGE PROTECTION**<br>~~a~~<br>~~|~~<br>~~C—“‘;‘CSCSCisC~~||4.00 to 5.25|5.75 to 7.00|15.00 to 18.00|20.00 to 25.00|30.00 to 37.00|
||**REMOTE SENSING**<br>~~|~~<br>~~C—“‘;‘CSCSCisC~~||Notprovided|||||
|**ISOLATION**<br>~~|~~<br>~~|~~<br>~~|~~|**INPUT-OUTPUT**<br>~~|~~<br>~~C—“‘;‘CSCSCisC~~<br>~~Po~~||3,000VAC 1minute,Cutoff current = 10mA,500VDC 100MWmin(At Room Temperature)|||||
||**INPUT-FG**<br>~~Po~~<br>~~|~~<br>~~C—“‘“CCsC~~||2,000VAC 1minute,Cutoff current = 10mA,500VDC 100MWmin(At Room Temperature)|||||
||**OUTPUT-FG**<br>~~|~~<br>~~C—“‘“CCsC~~<br>~~|~~||500VAC 1minute,Cutoff current = 25mA,500VDC 100MWmin(At Room Temperature)|||||
|**ENVIRONMENT**<br>~~|~~<br>~~|~~<br>~~|~~|**OPERATING TEMP.,HUMID.AND ALTITUDE** *2 <br>~~|~~<br>~~C—“‘“CCsC~~<br>~~|~~||-20 to +70C,20 - 90%RH(Non condensing),5,000m (16,500feet)max|||||
||**STORAGE TEMP.,HUMID.AND ALTITUDE**<br>~~|Po~~||-20 to +75C,20 - 90%RH(Non condensing),9,000m(30,000feet)max|||||
||**VIBRATION**<br>~~Po~~<br>~~|~~<br>~~C—“‘;‘CSC‘isC~~||10 - 55Hz,19.6m/s2 (2G),3minutesperiod,60minutes each alongX,Y and Z axis|||||
||**IMPACT**<br>~~|~~<br>~~C—“‘;‘CSC‘isC~~||196.1m/s2 (20G),11ms,once each X,Y and Z axis|||||
|**SAFETY AND**<br>**NOISE**<br>**REGULATIONS**<br>~~|~~<br>~~|~~|**AGENCY APPROVALS**<br>~~|~~<br>~~C—“‘;‘CSC‘isC~~<br>~~|~~||UL62368-1,C-UL(equivalent to CAN/CSA-C22.2No.62368-1),EN62368-1,Complies with DEN-AN|||||
||**CONDUCTED NOISE**<br>~~Po~~<br>~~|~~<br>~~C—“‘;‘CCCisd~~||Complies with CISPR11-B,CISPR32-B,EN55011-B,EN55032-B,FCC Part15-B,FCC Part18-B,VCCI-B|||||
||**HARMONIC ATTENUATOR** *6 <br>~~|~~<br>~~C—“‘;‘CCCisd~~||Complies with IEC61000-3-2(Class A) (No built-inpower factor correction)|||||
|**OTHERS**<br>~~|~~<br>~~|~~|**CASE SIZE/WEIGHT**<br>~~|~~<br>~~C—“‘;‘CCCisd~~<br>~~|~~<br>~~|~~<br>~~—“(t;i‘CSCCSCisdzS~~||31X78X85mm[1.22X3.07X3.35 inches] (without terminal block) (WXHXD)/ 180gmax(with cover : 210gmax)|||||
||**COOLING METHOD**<br>*2 <br>~~|~~<br>~~—“(t;i‘CSCCSCisdzS~~||Convection/Forced air(Requires external fan) (Refer to “Derating”)|||||
- *1 The listed options may affect the published standard specifications. Please contact us for detailed product specifications.
- *2 Derating is required.Please contact us for DC input.
- *3 At low load conditions, the burst mode operation will start. To check load regulation, you will need to measure the characteristics at average mode with instruments.
- *4 This is the value that measured on measuring board with capacitor of 22mF at 150mm from output terminal.
- *5 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
- *6
- Please contact us about another class. When two or more units are operating it may not comply with the IEC61000-3-2. Please contact us for details.
- To meet the specification, do not operate overload condition.
-
-
- Parallel operation is not possible.
- Sound noise may be generated by power supply in case of pulse load.
- Measured by 20MHz oscilloscope or Ripple-Noise meter
- (Equivalent to KEISOKU-GIKEN:RM104).
Ripple and ripple noise spec is change at Io=0 to 15% by burst operation.
**PDA-2**
January 29, 2026
**PDA15F**
## **Block diagram**
**==> picture [462 x 235] intentionally omitted <==**
**----- Start of picture text -----**<br>
FUSE<br>AC250V<br>1.25A INRUSH RECTIFIER<br>AC IN CURRENT NOISE AND<br>85 - 264VAC LIMIT FILTER FILTER<br>FG<br>TRANSFORMER<br>RECTIFIER<br>SWITCHING<br>CONTROL DEVICE AND DC OUT<br>FILTER<br>CURRENT<br>SENSING<br>OPTOCOUPLER<br>CONTROL<br>OPTOCOUPLER<br>OVER VOLTAGE<br>PROTECTION<br>**----- End of picture text -----**<br>
## **External view**
- *Extemal size of option J1, N1 and V is different from standard model and refer to 8 option of instruction manual for details.
**==> picture [348 x 172] intentionally omitted <==**
**----- Start of picture text -----**<br>
Output voltage<br>potentiometeradjustment 12.2±1.5 Cover name plate 16.5±2 Point 2 85<br>[0.48] [0.65] [3.35]<br>M3<br>+V Cover (option)<br>-V<br>FG<br>AC(L)<br>AC(N)<br>15.1±1.5 Terminal 31±0.5 36.5<br>[0.59] Cover 2×M3 [1.22] [1.44] Point 1<br>22.6±1.5 Mounting Hole<br>[0.89]<br>7.5 [0.3] 78<br>[3.07]<br>70.5 [2.78]<br>9.5 [0.37] 34.5 [1.36]<br>11.5 [0.45]<br>**----- End of picture text -----**<br>
**==> picture [398 x 93] intentionally omitted <==**
**----- Start of picture text -----**<br>
2×M3<br>Mounting Hole Name plate<br>* Tolerance : ±1 [±0.04]<br>* Weight : 180g max (with cover : 210g max)<br>* PCB Material / thickness : CEM3 / 1.6mm [0.06]<br>* Chassis material : Galvanized steel plate<br>* Dimensions in mm, [ ]= inches<br>* Mounting torque : 0.6N ・ m max<br>* Screw tightening torque : M3 0.8N ・ m max<br>* Please connect safety ground to the unit in 2-M3 holes<br>* Point 1 , Point 2 are thermometry points. Please refer to Instruction Manual 4.<br>60±0.5 5<br>[2.36] [0.2]<br>31 [1.22] 34.5 [1.36]<br>18<br>[0.71]<br>**----- End of picture text -----**<br>
**PDA-3**
January 29, 2026
**AC-DC Power Supplies Enclosed Type PDA30F** ~~YS~~
**Ordering information**
**PD A 30 F** O O
## R Ais (D)C ~~E~~ EK
1 2
3 4 5 6
1Series name
**==> picture [75 x 14] intentionally omitted <==**
**----- Start of picture text -----**<br>
Example recommended EMI/EMC filter<br>NAC-06-472<br>**----- End of picture text -----**<br>
2Single output
- 3Output wattage
4Universal input
5Output voltage
**==> picture [80 x 39] intentionally omitted <==**
**----- Start of picture text -----**<br>
High voltage pulse noise type : NAP series<br>Low leakage current type : NAM series<br>*A higher current rating EMI/EMC filter<br>may be recommended in view of the<br>other devices that could be connected<br>in parallel with the power supply.<br>**----- End of picture text -----**<br>
6Optional[*][1] N : with cover C: with Coating G: LOW leakage current J1 : VH(J.S.T.) connector type N1 : with DIN rail and Cover T5 : UL508[5V,12V,24V]
For option details, refer to Instruction Manual 8.1.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
||**MODEL**<br>~~es~~<br>~~Po~~|**MODEL**<br>~~es~~<br>~~Po~~|**PDA30F-3R3**<br>~~es~~<br>~~ee~~|**PDA30F-5**<br>~~es~~<br>~~QO~~|**PDA30F-12**<br>~~es~~<br>~~QO~~|**PDA30F-15**<br>~~es~~|**PDA30F-24**|
|---|---|---|---|---|---|---|---|
|**INPUT**|**VOLTAGE[VAC]**<br>*2 <br>~~Po~~||85 - 264 1f(Refer to “Derating” and Instruction Manual 1.1)<br>~~ee~~<br>~~QO~~|||||
||**CURRENT[A]**<br>~~a~~|**ACIN 100V**<br>~~a~~|0.42typ<br>~~a~~|0.62typ||||
|||**ACIN 230V**<br>~~a~~<br>~~a~~|0.22typ<br>~~a~~|0.32typ||||
||**FREQUENCY[Hz]**<br>~~Po~~||50 / 60(45 - 440)|||||
||**EFFICIENCY[%]**<br>~~EE~~|**ACIN 100V**<br>~~EE~~|82.5typ<br>~~EE~~|83.0typ<br>~~EE~~|82.0typ<br>~~EE~~|81.0typ<br>~~EE~~|83.5typ|
|||**ACIN 230V**<br>~~EE~~<br>~~a~~|84.5typ<br>~~EE~~|87.0typ<br>~~EE~~|85.5typ<br>~~EE~~|84.5typ<br>~~EE~~|86.5typ|
||**INRUSH CURRENT[A]**<br>~~PE~~<br>~~|~~|**ACIN 100V**<br>~~PE~~<br>~~|~~|15typ (Io=100%)at cold start|||||
|||**ACIN 230V**<br>~~PE~~<br>~~|~~|35typ (Io=100%)at cold start|||||
||**LEAKAGE CURRENT[mA]**<br>~~PE~~<br>~~|~~<br>~~Po~~||0.25 / 0.55 max(ACIN 100V / 240V,60Hz,Io=100%,Accordingto IEC62368-1,and DEN-AN)<br>~~a~~|||||
|**OUTPUT**|**VOLTAGE[V]**<br>~~es~~<br>~~a~~||3.3<br>~~es~~<br>~~a~~<br>~~es~~|5<br>~~es~~<br>~~a~~|12<br>~~es~~|15<br>~~es~~|24|
||**CURRENT[A]**<br>*2 <br>~~es~~<br>~~a~~||6.0<br>~~a~~<br>~~es~~<br>~~es~~|6.0<br>~~a~~<br>~~es~~|2.5<br>~~es~~|2.0<br>~~es~~|1.3|
||**LINE REGULATION[mV]**<br>*3 <br>~~a~~||20max<br>~~es~~|20max|48max|60max|96max|
||**LOAD REGULATION[mV]**<br>*3 <br>~~a~~||40max<br>~~a~~|40max|100max|120max|150max|
||**RIPPLE[mVp-p]**<br>*4<br>~~a~~|**0 to +55**C <br>~~a~~|80max<br>~~a~~|80max|120max|120max|120max|
|||**-20 to 0**C<br>~~a~~<br>~~a~~|140max<br>~~a~~|140max|160max|160max|160max|
|||**Io=0 to 15%** <br>~~a~~<br>~~a~~|300max<br>~~a~~<br>~~GQ~~|300max<br>~~GQ~~|300max<br>~~GQ~~|300max<br>~~GQ~~|300max|
||**RIPPLE NOISE[mVp-p]**<br>*4<br>~~a~~|**0 to +55**C <br>~~**a**~~|120max|120max|150max|150max|150max|
|||**-20 to 0**C<br>~~**a**~~|160max|160max|180max|180max|180max|
|||**Io=0 to 15%** <br>~~**a**~~|360max|360max|360max|360max|360max|
||**TEMPERATURE REGULATION[mV]**<br>~~a~~|**0 to +55**C <br>~~a~~|50max|50max|120max|150max|240max|
|||**-20 to +55**C <br>~~a~~<br>~~a~~|60max<br>~~QQ~~|60max<br>~~QQ~~|150max<br>~~QQ~~|180max<br>~~QQ~~|290max|
||**DRIFT[mV]**<br>*5 <br>~~a~~||20max|20max|48max|60max|96max|
||**START-UP TIME[ms]**<br>~~Po~~||80typ (ACIN 100V,Io=100%)|||||
||**HOLD-UP TIME[ms]**<br>~~Po~~||20typ (ACIN 100V,Io=100%)/ 150typ (ACIN 230V,Io=100%)|||||
||**OUTPUT VOLTAGE ADJUSTMENT RANGE[V]**<br>~~a~~||2.85 to 3.60|4.50 to 5.50|10.00 to 13.20|13.20 to 18.00|20.40 to 27.00|
||**OUTPUT VOLTAGE SETTING[V]**<br>~~a~~||3.30 to 3.40|5.00 to 5.15|12.00 to 12.48|15.00 to 15.60|24.00 to 24.96|
|**PROTECTION**<br>**CIRCUIT AND**<br>**OTHERS**<br>~~PL~~|**OVERCURRENT PROTECTION**<br>~~Po~~||Works over 105% of ratingand recovers automatically|||||
||**OVERVOLTAGE PROTECTION**<br>~~a~~<br>~~PL~~||4.00 to 5.25|5.75 to 7.00|15.00 to 18.00|20.00 to 25.00|30.00 to 37.00|
||**REMOTE SENSING**<br>~~PL~~||Notprovided|||||
|**ISOLATION**<br>~~PL~~|**INPUT-OUTPUT**<br>~~PLPo~~||3,000VAC 1minute,Cutoff current = 10mA,500VDC 100MWmin(At Room Temperature)|||||
||**INPUT-FG**<br>~~Po~~||2,000VAC 1minute,Cutoff current = 10mA,500VDC 100MWmin(At Room Temperature)|||||
||**OUTPUT-FG**<br>~~LP~~||500VAC 1minute,Cutoff current = 25mA,500VDC 100MWmin(At Room Temperature)|||||
|**ENVIRONMENT**|**OPERATING TEMP.,HUMID.AND ALTITUDE** *2 <br>~~Po~~||-20 to +70C,20 - 90%RH(Non condensing),5,000m (16,500feet)max|||||
||**STORAGE TEMP.,HUMID.AND ALTITUDE**<br>~~Po~~||-20 to +75C,20 - 90%RH(Non condensing),9,000m(30,000feet)max|||||
||**VIBRATION**<br>~~Po~~||10 - 55Hz,19.6m/s2 (2G),3minutesperiod,60minutes each alongX,Y and Z axis|||||
||**IMPACT**<br>~~Po~~||196.1m/s2 (20G),11ms,once each X,Y and Z axis|||||
|**SAFETY AND**<br>**NOISE**<br>**REGULATIONS**|**AGENCY APPROVALS**<br>~~Po~~||UL62368-1,C-UL(equivalent to CAN/CSA-C22.2No.62368-1),EN62368-1,Complies with DEN-AN|||||
||**CONDUCTED NOISE**<br>~~Po~~||Complies with CISPR11-B,CISPR32-B,EN55011-B,EN55032-B,FCC Part15-B,FCC Part18-B,VCCI-B|||||
||**HARMONIC ATTENUATOR** *6 <br>~~Po~~||Complies with IEC61000-3-2(Class A) (No built-inpower factor correction)|||||
|**OTHERS**|**CASE SIZE/WEIGHT**<br>~~Po~~||31X78X103mm[1.22X3.07X4.06 inches] (without terminal block) (WXHXD)/ 250gmax(with cover : 280gmax)|||||
||**COOLING METHOD**<br>*2 <br>~~Pe~~||Convection/Forced air(Requires external fan) (Refer to “Derating”)|||||
- *1 The listed options may affect the published standard specifications. Please contact us for detailed product specifications.
- *2 Derating is required.Please contact us for DC input.
- *3 At low load conditions, the burst mode operation will start. To check load regulation, you will need to measure the characteristics at average mode with instruments.
- *4 This is the value that measured on measuring board with capacitor of 22mF at 150mm from output terminal.
- *5 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
- *6
- Please contact us about another class. When two or more units are operating it may not comply with the IEC61000-3-2. Please contact us for details.
- To meet the specification, do not operate overload condition.
-
-
- Parallel operation is not possible.
-
- Sound noise may be generated by power supply in case of pulse load.
- Measured by 20MHz oscilloscope or Ripple-Noise meter
- (Equivalent to KEISOKU-GIKEN:RM104).
Ripple and ripple noise spec is change at Io=0 to 15% by burst operation.
**PDA-4**
January 29, 2026
**PDA30F**
## **Block diagram**
**==> picture [462 x 236] intentionally omitted <==**
**----- Start of picture text -----**<br>
FUSE<br>AC250V<br>2.5A INRUSH RECTIFIER<br>AC IN CURRENT NOISE AND<br>85 - 264VAC LIMIT FILTER FILTER<br>FG<br>TRANSFORMER<br>RECTIFIER<br>SWITCHING<br>CONTROL DEVICE AND DC OUT<br>FILTER<br>CURRENT<br>SENSING<br>OPTOCOUPLER<br>CONTROL<br>OPTOCOUPLER<br>OVER VOLTAGE<br>PROTECTION<br>**----- End of picture text -----**<br>
## **External view**
- *Extemal size of option J1, N1 and V is different from standard model and refer to 8 option of instruction manual for details.
**==> picture [426 x 276] intentionally omitted <==**
**----- Start of picture text -----**<br>
Output voltage<br>potentiometeradjustment 12.2±1.5 16.5±2 Point 2 103<br>[0.48] Cover name plate [0.65] [4.06]<br>M3<br>+V<br>Cover (option)<br>-V<br>FG<br>AC(L)<br>AC(N)<br>Terminal<br>15.1±1.5 Cover 46±0.5 40.5<br>[0.59] [1.81] [1.59]<br>22.6[0.89]±1.5 2×M3 Point 1<br>Mounting Hole<br>2×M3<br>Mounting Hole Name plate<br>* Tolerance : ±1 [±0.04]<br>* Weight : 250g max (with cover : 280g max)<br>* PCB Material / thickness : CEM3 / 1.6mm [0.06]<br>* Chassis material : Galvanized steel plate<br>* Dimensions in mm, [ ]= inches<br>* Mounting torque : 0.6N ・ m max<br>* Screw tightening torque : M3 0.8N ・ m max<br>* Please connect safety ground to the unit in 2-M3 holes<br>* Point 1 , Point 2 are thermometry points. Please refer to Instruction Manual 4. 75±0.5 8.5<br>[2.95] [0.33]<br>05. 7.5 [0.3] 78 [3.07]<br>7 [2.78]<br>9.5 [0.37] 36.5 [1.44]<br>11.5 [0.45]<br>31 [1.22] 34.5 [1.36]<br>18<br>[0.71]<br>**----- End of picture text -----**<br>
**PDA-5**
January 29, 2026
**AC-DC Power Supplies Enclosed Type PDA50F** ~~|~~
**Ordering information**
**PD A 50 F** O O
1 2 3 4 5 6
## R ‘AL: (D) C ~~E~~ YK
**Example recommended EMI/EMC filter NAC-06-472**
1Series name
- 2Single output
- 3Output wattage
4Universal input
- 5Output voltage
High voltage pulse noise type : NAP series Low leakage current type : NAM series *A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply.
6Optional[*][1] N : with cover C: with Coating G: LOW leakage current J1 : VH(J.S.T.) connector type N1 : with DIN rail and Cover T5 : UL508[24V]
For option details, refer to Instruction Manual 8.1.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
||**MODEL**<br>~~a~~|**MODEL**<br>~~a~~|**PDA50F-3R3**|**PDA50F-5**<br>~~(~~|**PDA50F-12**<br>~~(~~|**PDA50F-15**|**PDA50F-24**|**PDA50F-36**|**PDA50F-48**|
|---|---|---|---|---|---|---|---|---|---|
|**INPUT**<br>~~|~~|**VOLTAGE[VAC]**<br>*2 <br>~~Po~~<br>~~eee~~<br>~~|~~||85 - 264 1f(Refer to Instruction Manual 1.1)<br><br>~~eee~~|||||||
||**CURRENT[A]**<br><br>~~a~~<br>~~|~~|**ACIN 100V**<br>~~a~~<br>~~eee~~<br>|0.72typ<br>~~a~~<br>~~eee~~|1.05typ||||||
|||**ACIN 230V**<br>~~a~~<br>~~eee~~<br>|0.38typ<br>~~a~~<br>~~eee~~|0.52typ||||||
||**FREQUENCY[Hz]**<br>~~eee~~<br>~~|ee~~||50 / 60(45 - 440)<br>~~eee~~<br>~~es~~<br>~~es eeeeee~~<br>~~ee~~|||||||
||**EFFICIENCY[%]**<br>~~|ee~~<br>~~|~~|**ACIN 100V**<br>~~eee~~<br>~~e~~|80.0typ<br>~~eee~~<br>~~es~~|81.5typ<br>~~es ee~~|82.5typ<br>~~ee~~|83.0typ<br>~~ee~~|85.0typ<br>~~ee~~|85.0typ<br>~~ee~~|86.0typ<br>~~ee~~|
|||**ACIN 230V**<br>~~e~~<br>~~|~~|82.5typ<br>~~es~~|85.0typ<br>~~es ee~~|85.0typ<br>~~ee~~|85.0typ<br>~~ee~~|87.5typ<br>~~ee~~|87.5typ<br>~~ee~~|88.5typ<br>~~ee~~|
||**INRUSH CURRENT[A]**<br>~~ee~~<br>~~|~~<br>~~ES~~|**ACIN 100V**<br>~~e~~<br>~~|~~<br>~~ES~~|15typ (Io=100%)at cold start<br>~~es~~<br>~~es ee ee ee~~<br>~~ee~~|||||||
|||**ACIN 230V**<br>~~|~~<br>~~ES~~|35typ (Io=100%)at cold start|||||||
||**LEAKAGE CURRENT[mA]**<br>~~ES~~<br>~~LT~~||0.3 / 0.65 max(ACIN 100V / 240V,60Hz,Io=100%,Accordingto IEC62368-1,and DEN-AN)|||||||
|**OUTPUT**<br>~~|~~<br>~~|~~|**VOLTAGE[V]**<br>~~QC~~||3.3<br>~~QC~~|5<br>~~QC~~|12<br>~~QC~~|15<br>~~QC~~|24<br>~~QC~~|36<br>~~QC~~|48|
||**CURRENT[A]**<br>*2 <br>~~(CO~~||10<br>~~(CO~~|10<br>~~(CO~~|4.3<br>~~(CO~~|3.5<br>~~(CO~~|2.2<br>~~(CO~~|1.4<br>~~(CO~~|1.1|
||**LINE REGULATION[mV]**<br>*3 <br>~~eG~~||20max<br>~~eG~~|20max<br>~~OG~~|48max<br>~~OG~~|60max<br>~~OG~~|96max|144max|192max|
||**LOAD REGULATION[mV]**<br>*3 <br>~~RG~~||40max<br>~~RG~~|40max<br>~~OG~~|100max<br>~~OG~~|120max<br>~~OG~~|150max|240max|240max|
||**RIPPLE[mVp-p]**<br>*4|**0 to +50**C <br>~~a~~|80max<br>~~QQ~~|80max<br>~~QQ~~|120max<br>~~QQ~~|120max<br>~~QQ~~|120max<br>~~QQ~~|150max<br>~~QQ~~|200max|
|||**-20 to 0**C<br>~~a~~|140max<br>~~eG~~|140max<br>~~eG~~|160max<br>~~eG~~|160max<br>~~eG~~|160max<br>~~eG~~|200max<br>~~eG~~|250max|
|||**Io=0 to 15%** <br>~~a~~|300max|300max|300max|300max|300max|300max|300max|
||**RIPPLE NOISE[mVp-p]**<br>*4<br>~~ee~~|**0 to +50**C <br>~~a~~|120max<br>~~GG~~|120max<br>~~GG~~|150max<br>~~GG~~|150max<br>~~GG~~|150max<br>~~GG~~|250max<br>~~GG~~|300max|
|||**-20 to 0**C<br>~~a~~|160max|160max|180max|180max|180max|300max|480max|
|||**Io=0 to 15%** <br>~~a~~<br>~~ee~~|360max<br>~~ee ee~~|360max<br>~~ee ee~~|360max<br>~~ee~~|360max|360max<br>~~eee~~|360max<br>~~eee~~|360max<br>~~eee~~|
||**TEMPERATURE REGULATION[mV]**<br>~~ee~~|**0 to +50**C <br>~~ee~~|50max<br>~~ee ee~~|50max<br>~~ee ee~~|120max<br>~~ee~~|150max|240max<br>~~eee~~|360max<br>~~eee~~|480max<br>~~eee~~|
|||**-20 to +50**C <br>~~ee~~<br>~~PO~~|60max<br>~~ee ee~~<br>~~PO~~|60max<br>~~ee ee~~<br>~~PO~~|150max<br>~~ee~~<br>~~PO~~|180max<br>~~PO~~|290max<br>~~eee~~<br>~~PO~~|450max<br>~~eee~~<br>~~PO~~|600max<br>~~eee~~|
||**DRIFT[mV]**<br>*5 <br>~~ee~~<br>~~eG~~<br>~~|~~<br>~~t—~—“‘CsCSC‘isC~~||20max<br>~~ee ee~~<br>~~eG~~|20max<br>~~ee ee~~<br>~~GG~~|48max<br>~~ee~~<br>~~GG~~|60max<br>~~GG~~|96max<br>~~eee~~|144max<br>~~eee~~|192max<br>~~eee~~|
||**START-UP TIME[ms]**<br>~~|~~<br>~~t—~—“‘CsCSC‘isC~~<br>~~|~~<br>~~C—C‘C‘isCO~~||80typ (ACIN 100V,Io=100%)|||||||
||**HOLD-UP TIME[ms]**<br>~~|~~<br>~~t—~—“‘CsCSC‘isC~~<br>~~|~~<br>~~C—C‘C‘isCO~~||20typ (ACIN 100V,Io=100%)/ 140typ (ACIN 230V,Io=100%)|||||||
||**OUTPUT VOLTAGE ADJUSTMENT RANGE[V]**<br>~~|~~<br>~~C—C‘C‘isCO~~<br>~~CG~~||2.85 to 3.63<br>~~CG~~|4.00 to 5.50<br>~~CG~~|10.00 to 13.20<br>~~CG~~|13.20 to 18.00<br>~~CG~~|19.20 to 27.00<br>~~CG~~|28.80 to 39.60<br>~~CG~~|39.00 to 53.00|
||**OUTPUT VOLTAGE SETTING[V]**<br>~~OQ~~||3.30 to 3.40<br>~~OQ~~|5.00 to 5.15<br>~~OQ~~|12.00 to 12.48<br>~~OQ~~|15.00 to 15.60<br>~~OQ~~|24.00 to 24.96<br>~~OQ~~|36.00 to 37.44<br>~~OQ~~|48.00 to 49.92|
|**PROTECTION**<br>**CIRCUIT AND**<br>**OTHERS**|**OVERCURRENT PROTECTION**<br>~~Pr~~||Works over 105% of ratingand recovers automatically|||||||
||**OVERVOLTAGE PROTECTION**<br>~~GG~~||4.00 to 5.25<br>~~GG~~|5.75 to 7.00<br>~~GG~~|15.00 to 18.00<br>~~GG~~|20.00 to 25.00<br>~~GG~~|30.00 to 37.00<br>~~GG~~|43.00 to 50.00<br>~~GG~~|58.00 to 67.00|
||**REMOTE SENSING**<br>~~fe~~||Notprovided|||||||
|**ISOLATION**<br>~~|~~|**INPUT-OUTPUT**<br>~~Po~~<br>~~|~~<br>~~C—“(C:isCiz~~||3,000VAC 1minute,Cutoff current = 10mA,500VDC 100MWmin(At Room Temperature)|||||||
||**INPUT-FG**<br>~~|~~<br>~~C—“(C:isCiz~~||2,000VAC 1minute,Cutoff current = 10mA,500VDC 100MWmin(At Room Temperature)|||||||
||**OUTPUT-FG**<br>~~|~~<br>~~C—“(C:isCiz~~<br>~~Po~~||500VAC 1minute,Cutoff current = 25mA,500VDC 100MWmin(At Room Temperature)|||||||
|**ENVIRONMENT**<br>~~||~~|**OPERATING TEMP.,HUMID.AND ALTITUDE** *2 <br>~~Po~~<br>~~||~~||-20 to +70C,20 - 90%RH(Non condensing),5,000m (16,500feet)max|||||||
||**STORAGE TEMP.,HUMID.AND ALTITUDE**<br>~~||~~||-20 to +75C,20 - 90%RH(Non condensing),9,000m(30,000feet)max|||||||
||**VIBRATION**<br>~~||~~||10 - 55Hz,19.6m/s2 (2G),3minutesperiod,60minutes each alongX,Y and Z axis|||||||
||**IMPACT**<br>~~||PO~~||196.1m/s2 (20G),11ms,once each X,Y and Z axis|||||||
|**SAFETY AND**<br>**NOISE**<br>**REGULATIONS**<br>~~|~~|**AGENCY APPROVALS**<br>~~Po~~<br>~~|~~||UL62368-1,C-UL(equivalent to CAN/CSA-C22.2No.62368-1),EN62368-1,Complies with DEN-AN|||||||
||**CONDUCTED NOISE**<br>~~|~~||Complies with CISPR11-B,CISPR32-B,EN55011-B,EN55032-B,FCC Part15-B,FCC Part18-B,VCCI-B|||||||
||**HARMONIC ATTENUATOR** *6 <br>~~|Po~~||Complies with IEC61000-3-2(Class A) (No built-inpower factor correction)|||||||
|**OTHERS**|**CASE SIZE/WEIGHT**<br>~~Po~~||31X82X120mm[1.22X3.23X4.72 inches] (without terminal block) (WXHXD)/ 330gmax(with cover : 370gmax)|||||||
||**COOLING METHOD**<br>*2 <br>~~Pe~~||Convection/Forced air(Requires external fan) (Refer to “Derating”)|||||||
- *1 The listed options may affect the published standard specifications. Please contact us for detailed product specifications.
- *2 Derating is required.Please contact us for DC input.
- *3 At low load conditions, the burst mode operation will start. To check load regulation, you will need to measure the characteristics at average mode with instruments.
- *4 This is the value that measured on measuring board with capacitor of 22mF at 150mm from output terminal.
- *5 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
- *6
- Please contact us about another class. When two or more units are operating it may not comply with the IEC61000-3-2. Please contact us for details.
- To meet the specification, do not operate overload condition.
-
-
- Parallel operation is not possible.
-
- Sound noise may be generated by power supply in case of pulse load.
- Measured by 20MHz oscilloscope or Ripple-Noise meter
- (Equivalent to KEISOKU-GIKEN:RM104).
Ripple and ripple noise spec is change at Io=0 to 15% by burst operation.
**PDA-6**
January 29, 2026
**PDA50F**
## **Block diagram**
**==> picture [462 x 236] intentionally omitted <==**
**----- Start of picture text -----**<br>
FUSE<br>AC250V<br>2.5A INRUSH RECTIFIER<br>AC IN CURRENT NOISE AND<br>85 - 264VAC LIMIT FILTER FILTER<br>FG<br>TRANSFORMER<br>RECTIFIER<br>SWITCHING<br>CONTROL DEVICE AND DC OUT<br>FILTER<br>CURRENT<br>SENSING<br>OPTOCOUPLER<br>CONTROL<br>OPTOCOUPLER<br>OVER VOLTAGE<br>PROTECTION<br>**----- End of picture text -----**<br>
## **External view**
- *Extemal size of option J1, N1 and V is different from standard model and refer to 8 option of instruction manual for details.
**==> picture [446 x 259] intentionally omitted <==**
**----- Start of picture text -----**<br>
Output voltage<br>adjustment 11.2±1.5 16.5±2 120<br>potentiometer [0.44] [0.65] [4.72]<br>Cover name plate<br>M3<br>+V Cover (option)<br>-V<br>FG<br>2×M3<br>AC(L) Mounting Hole<br>AC(N)<br>14.1±1.5 77±0.5 4<br>[0.56] Terminal [3.03] [0.16]<br>21.6[0.85]±1.5 Cover Point 2 2×M3 Point 1<br>Mounting Hole Name plate<br>* Tolerance : ±1 [±0.04]<br>* Weight : 330g max (with cover : 370g max)<br>* PCB Material / thickness : CEM3 / 1.6mm [0.06]<br>* Chassis material : Galvanized steel plate<br>* Dimensions in mm, [ ]= inches<br>* Mounting torque : 0.6N ・ m max<br>* Screw tightening torque : M3 0.8N ・ m max<br>* Please connect safety ground to the unit in 2-M3 holes 88±0.5 11<br>* Point 1 , Point 2 are thermometry points. Please refer to Instruction Manual 4. [3.46] [0.43]<br>0.6 [0.02]<br>7.5 [0.3] 82 [3.23]<br>70.5 [2.78]<br>9.5 [0.37] 35 [1.38]<br>11.5 [0.45]<br>31 [1.22] 34.5 [1.36]<br>18<br>[0.71]<br>**----- End of picture text -----**<br>
**PDA-7**
January 29, 2026
**AC-DC Power Supplies Enclosed Type PDA100F** ~~|~~
**Ordering information**
**PD A 100 F** O O
1
2 3 4 5 6
Wi;° R UK (D) C ~~E~~ LK
**Example recommended EMI/EMC filter NAC-06-472**
1Series name 2Single output
3Output wattage
4Universal input
5Output voltage
6Optional[*][1] N : with cover : C: with Coating G: LOW leakage current High voltage pulse noise type : NAP seriesLow leakage current type : NAM series J1 : VH(J.S.T.) Connector type *A higher current rating EMI/EMC filter may be recommended in view of the (only -12, -15, -24, -36, -48)N1 : with DIN rail and Cover other devices that could be connected T5 : UL508[24V] in parallel with the power supply.
For option details, refer to Instruction Manual 8.1.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
||**MODEL**<br>~~ee~~|**MODEL**<br>~~ee~~|**PDA100F-3R3 **|**PDA100F-5**|**PDA100F-12**|**PDA100F-15**|**PDA100F-24**|**PDA100F-36**|**PDA100F-48**|
|---|---|---|---|---|---|---|---|---|---|
|**INPUT**<br>~~|~~|**VOLTAGE[VAC]**<br>*2 <br>~~ee~~<br>~~PO~~<br>~~2~~<br>~~eee~~||85 - 264 1f(Refer to Instruction Manual 1.1)<br>~~eee~~|||||||
||**CURRENT[A]**<br>~~2~~|**ACIN 100V**<br>~~eee~~|0.9typ<br>~~eee~~|1.3typ<br>~~eee~~||||||
|||**ACIN 230V**<br>~~eee~~<br>~~a~~|0.4typ<br>~~eee~~<br>~~a~~|0.6typ<br>~~eee~~||||||
||**FREQUENCY[Hz]**<br>~~2~~<br>~~eee~~<br>~~Po~~<br>~~ee~~||50 / 60(45 - 66)<br>~~eee~~<br>~~es~~<br>~~es ee~~<br>~~eeee~~<br>~~ee~~|||||||
||**EFFICIENCY[%]**<br>~~ee~~|**ACIN 100V**<br>~~e~~|85.0typ<br>~~es~~|87.0typ<br>~~es ee~~|88.5typ<br>~~ee~~|88.5typ<br>~~ee~~|87.5typ<br>~~ee~~|87.5typ<br>~~ee~~|88.0typ<br>~~ee~~|
|||**ACIN 230V**<br>~~e~~<br>~~a~~|86.5typ<br>~~es~~<br>~~DC~~|89.5typ<br>~~es ee~~<br>~~DC~~|91.0typ<br>~~ee~~<br>~~DC~~|91.0typ<br>~~ee~~<br>~~DC~~|89.5typ<br>~~ee~~<br>~~DC~~|90.0typ<br>~~ee~~<br>~~DC~~|90.5typ<br>~~ee~~|
||**POWER FACTOR**<br>**(Io=100%)**<br>~~ee~~<br>~~——~~<br>~~|~~|**ACIN 100V**<br>~~e~~<br>~~——~~|0.97typ<br>~~es~~<br>~~——~~|0.97typ<br>~~es ee~~<br>~~ee ee~~<br>~~ee~~||||||
|||**ACIN 230V**<br>~~——~~<br>~~a~~|0.81typ<br>~~——~~<br>~~a~~|0.87typ||||||
||**INRUSH CURRENT[A]**<br>~~——~~<br>~~|~~|**ACIN 100V**<br>~~——~~<br>~~a~~|15typ (Io=100%)at cold start<br>~~——~~<br>~~a~~|||||||
|||**ACIN 230V**<br>~~a~~<br>~~P|~~|35typ (Io=100%)at cold start<br>~~a~~|||||||
||**LEAKAGE CURRENT[mA]**<br>~~a~~<br>~~|~~<br>~~P|~~<br>~~PT~~<br>~~a~~||0.4 / 0.75 max(ACIN 100V / 240V,60Hz,Io=100%,Accordingto IEC62368-1,and DEN-AN)<br>~~a~~<br>~~OQ~~<br>~~CO~~|||||||
|**OUTPUT**|**VOLTAGE[V]**<br>~~a~~||3.3|5<br>~~OQ~~|12<br>~~OQ~~|15<br>~~CO~~|24<br>~~CO~~|36|48|
||**CURRENT[A]**<br>*2 <br>~~a~~<br>~~QO~~<br>~~Qe~~||20<br>~~QO~~<br>~~Qe~~|20<br>~~OQ~~<br>~~QO~~|8.5<br>~~OQ~~<br>~~QO~~|7<br>~~CO~~<br>~~QO~~<br>~~OO~~|4.5<br>~~CO~~<br>~~QO~~<br>~~OO~~|2.8<br>~~QO~~|2.1|
||**LINE REGULATION[mV]**<br>*3 <br>~~QQ~~<br>~~Qe~~||20max<br>~~QQ~~<br>~~Qe~~|20max<br>~~QQ~~|48max<br>~~QQ~~|60max<br>~~QQ~~<br>~~OO~~|96max<br>~~QQ~~<br>~~OO~~|144max<br>~~QQ~~|192max|
||**LOAD REGULATION[mV]**<br>*3 <br>~~Qe~~||40max<br>~~Qe~~|40max<br>~~QQ~~|100max<br>~~QQ~~|120max<br>~~OO~~<br>~~QQ~~|150max<br>~~OO~~|240max|240max|
||**RIPPLE[mVp-p]**<br>*4|**0 to +50**C <br>~~a~~|80max|80max<br>~~Qe~~|120max<br>~~Qe~~|120max|120max|150max|150max|
|||**-20 to 0**C<br>~~a~~|140max<br>~~GQ~~|140max<br>~~GQ~~|160max<br>~~GQ~~|160max<br>~~GQ~~|160max<br>~~GQ~~|200max<br>~~GQ~~|200max|
|||**Io=0 to 15%** <br>~~a~~|300max<br>~~GQ~~|300max<br>~~GQ~~|360max<br>~~GQ~~|500max<br>~~GQ~~|500max<br>~~GQ~~|500max<br>~~GQ~~|500max|
||**RIPPLE NOISE[mVp-p]**<br>*4|**0 to +50**C <br>~~a ~~|120max<br> ~~a~~|120max<br>~~Ge~~|150max<br>~~Ge~~|150max|150max|250max|250max|
|||**-20 to 0**C<br>~~aa~~|160max<br>~~aa~~|160max<br>~~aa~~|180max|180max|180max|300max|300max|
|||**Io=0 to 15%** <br>~~a~~<br>~~a~~|360max<br>~~aGC~~<br>|360max<br>~~GC~~<br>~~ee~~<br>|400max<br>~~GC~~<br>|600max<br>~~GC~~<br>~~ee~~<br>|600max<br>~~GC~~<br>~~ee~~<br>|600max<br>~~GC~~<br>~~ee~~<br>|600max|
||**TEMPERATURE REGULATION[mV]**<br>~~es~~|**0 to +50**C <br>~~es~~<br>~~a~~|50max<br>~~es~~<br>|50max<br>~~es~~<br>~~ee~~<br>|120max<br>~~es~~<br>|150max<br>~~es~~<br>~~ee~~<br>|240max<br>~~es~~<br>~~ee~~<br>|360max<br>~~es~~<br>~~ee~~<br>|480max|
|||**-20 to +50**C <br>~~es~~<br>~~a~~|60max<br>~~es~~<br>~~QC~~|60max<br>~~es~~<br>~~ee~~<br>~~QC~~|150max<br>~~es~~<br>~~QC~~|180max<br>~~es~~<br>~~ee~~<br>~~QC~~|290max<br>~~es~~<br>~~ee~~<br>~~QC~~|450max<br>~~es~~<br>~~ee~~<br>~~QC~~|600max|
||**DRIFT[mV]**<br>*5 <br>~~a~~<br>~~Qe~~||20max<br><br>~~Qe~~|20max<br>~~ee~~<br><br>~~QO~~|48max<br><br>~~QO~~|60max<br>~~ee~~<br><br>~~QO~~|96max<br>~~ee~~<br>|144max<br>~~ee~~<br>|192max|
||**START-UP TIME[ms]**<br>~~PT~~||100typ (ACIN 100V,Io=100%)|||||||
||**HOLD-UP TIME[ms]**<br>~~PT~~<br>~~Ge~~||20typ (ACIN 100V,Io=100%)<br>~~CO~~<br>~~Ge~~|||||||
||**OUTPUT VOLTAGE ADJUSTMENT RANGE[V]**<br>~~GG~~<br>~~Ge~~||2.85 to 3.63<br>~~GG~~<br>~~Ge~~|4.00 to 5.50<br>~~GG~~|10.00 to 13.20<br>~~GG~~|13.20 to 18.00<br>~~GG~~<br>~~CO~~|19.20 to 27.00<br>~~GG~~<br>~~CO~~|28.80 to 39.60<br>~~GG~~|39.00 to 53.00|
||**OUTPUT VOLTAGE SETTING[V]**<br>~~Ge~~||3.30 to 3.40<br>~~Ge~~|5.00 to 5.15<br>~~QQ~~|12.00 to 12.48<br>~~QQ~~|15.00 to 15.60<br>~~CO~~<br>~~QQ~~|24.00 to 24.96<br>~~CO~~|36.00 to 37.44|48.00 to 49.92|
|**PROTECTION**<br>**CIRCUIT AND**<br>**OTHERS**|**OVERCURRENT PROTECTION**<br>~~PT~~<br>~~PO~~||Works over 105% of ratingand recovers automatically<br>~~GO~~|||||||
||**OVERVOLTAGE PROTECTION**<br>~~QC~~<br>~~PO~~||4.00 to 5.25<br>~~QC~~|5.75 to 7.00<br>~~QC~~|15.00 to 18.00<br>~~QC~~|20.00 to 25.00<br>~~QC~~<br>~~GO~~|30.00 to 37.00<br>~~QC~~<br>~~GO~~|43.00 to 50.00<br>~~QC~~|58.00 to 67.00|
||**REMOTE SENSING**<br>~~PO~~||Notprovided<br>~~GO~~|||||||
|**ISOLATION**|**INPUT-OUTPUT**<br>~~PT~~||3,000VAC 1minute,Cutoff current = 10mA,500VDC 100MWmin(At Room Temperature)|||||||
||**INPUT-FG**<br>~~PO~~||2,000VAC 1minute,Cutoff current = 10mA,500VDC 100MWmin(At Room Temperature)|||||||
||**OUTPUT-FG**<br>~~PO~~||500VAC 1minute,Cutoff current = 25mA,500VDC 100MWmin(At Room Temperature)|||||||
|**ENVIRONMENT**|**OPERATING TEMPERATURE,HUMID** *2 <br>~~PO~~||-20 to +70C,20 - 90%RH(Non condensing)|||||||
||**STORAGE TEMPERATURE,HUMID**<br>~~PO~~||-20 to +75C,20 - 90%RH(Non condensing)|||||||
||**VIBRATION**<br>~~PO~~||10 - 55Hz,19.6m/s2 (2G),3minutesperiod,60minutes each alongX,Y and Z axis|||||||
||**IMPACT**<br>~~PO~~||196.1m/s2 (20G),11ms,once each X,Y and Z axis|||||||
|**SAFETY AND**<br>**NOISE**<br>**REGULATIONS**|**AGENCY APPROVALS**<br>~~Po~~||UL62368-1,C-UL(equivalent to CAN/CSA-C22.2No.62368-1),EN62368-1,Complies with DEN-AN|||||||
||**CONDUCTED NOISE**<br>~~PO~~||Complies with CISPR11-B,CISPR32-B,EN55011-B,EN55032-B,FCC Part15-B,FCC Part18-B,VCCI-B|||||||
||**HARMONIC ATTENUATOR** *6 <br>~~PO~~||Complies with IEC61000-3-2(Class A)|||||||
|**OTHERS**|**CASE SIZE/WEIGHT**<br>~~Po~~||32X93X147mm[1.26×3.66×5.79 inches] (without terminal block) (WXHXD)/ 440gmax(with cover : 500gmax)|||||||
||**COOLING METHOD**<br>*2 <br>~~PO~~||Convection/Forced air(Refer to “Derating”)|||||||
- *1 The listed options may affect the published standard specifications. Please contact us for detailed product specifications.
- *2 Derating is required.Please contact us for DC input.
- *3 At low load conditions, the burst mode operation will start. To check load regulation, you will need to measure the characteristics at average mode with instruments.
- *4 This is the value that measured on measuring board with capacitor of 22mF at 150mm from output terminal.
Measured by 20MHz oscilloscope or Ripple-Noise meter
- (Equivalent to KEISOKU-GIKEN:RM104).
Ripple and ripple noise spec is change at Io=0 to 15% by burst operation.
- *5
- Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
- *6
- Please contact us about another class. When two or more units are operating it may not comply with the IEC61000-3-2. Please contact us for details.
- To meet the specification, do not operate overload condition.
- Parallel operation is not possible.
- Sound noise may be generated by power supply in case of pulse load.
**PDA-8**
January 29, 2026
## **PDA100F**
## **Block diagram**
**==> picture [450 x 222] intentionally omitted <==**
**----- Start of picture text -----**<br>
FUSE<br>AC250V 3.15A INRUSH<br>NOISE<br>AC IN 85 - 264VAC RECTIFIER CURRENT<br>FILTER<br>LIMIT<br>FG<br>BOOSTER CURRENT<br>INDUCTOR SENSING TRANSFORMER<br>RECTIFIER RECTIFIER<br>SWITCHING<br>AND DEVICE AND DC OUT<br>FILTER FILTER<br>SWITCHING<br>DEVICE<br>CURRENT<br>SENSING<br>OPTOCOUPLER<br>OVER VOLTAGE<br>CONTROL PROTECTION<br>OPTOCOUPLER<br>CONTROL CONTROL<br>**----- End of picture text -----**<br>
## **External view**
- *Extemal size of option J1, N1 and V is different from standard model and refer to 8 option of instruction manual for details.
**==> picture [447 x 277] intentionally omitted <==**
**----- Start of picture text -----**<br>
Cover<br>Output voltage 11.5±1.5 Point ①<br>potentiometercadjustment [0.45] Cover name plate 13.5[0.53]±2 [5.79]147<br>M4<br>+V<br>+V<br>-V<br>-V<br>FG ( )<br>2×M3<br>AC(L) Mounting<br>Hole<br>AC(N)<br>14.5±1.5 124±0.5 4<br>[0.57] TerminalCover [4.88] [0.16]<br>24±1.5<br>[0.94] 4×M3<br>Name plate Mounting<br>Hole<br>* Tolerance : ±1<br>* Weight : 440g max (with cover : 500g max)<br>* PCB Material / thickness : FR-4 / 1.6mm [0.06] 105.5±0.5<br>* Chassis material : Aluminum [4.15] 112.5±0.5 15<br>* Dimensions in mm, [ ]= inches<br>* Mounting torque : 0.6N ・ m max [4.43] [0.59]<br>0.6<br>[0.02]<br>93<br>[3.66]<br>81 [3.19] 8.6 [0.34]<br>10 [0.39] 33.5 [1.32]<br>10±1.5 [0.39]<br>18 13±0.5 [0.51] 32[1.26] 35 [1.38]<br>[0.71] 9.5 [0.37]<br>**----- End of picture text -----**<br>
- Screw tightening torque : M4 1.6N ・ m max
- Please connect safety ground to the FG terminal on the unit.
- Point 1 is the thermometry points. Please refer to Instruction Manual 4.
**PDA-9**
January 29, 2026
**Ordering information**
**AC-DC Power Supplies Enclosed Type**
**PD A 150 F** O O
## **PDA150F**
**==> picture [4 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
" R<br>**----- End of picture text -----**<br>
1
2 3 4 5 6
1Series name 2Single output 3Output wattage 4Universal input
**Example recommended EMI/EMC filter NAC-06-472**
5Output voltage 6Optional[*][1] N : with cover C: with Coating G: LOW leakage current J1 : VH(J.S.T.) Connector type (only -12, -15, -24, -36, -48) N1 : with DIN rail and Cover T5 : UL508[24V]
High voltage pulse noise type : NAP series Low leakage current type : NAM series *A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply.
For option details, refer to Instruction Manual 8.1.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
||**MODEL**<br>~~a~~|**MODEL**<br>~~a~~|**PDA150F-3R3 **|**PDA150F-5**|**PDA150F-12**|**PDA150F-15**|**PDA150F-24**|**PDA150F-36**|**PDA150F-48**|
|---|---|---|---|---|---|---|---|---|---|
|**INPUT**|**VOLTAGE[VAC]**<br>*2 <br>~~Po~~<br>~~lleee~~||85 - 264 1f(Refer to Instruction Manual 1.1)<br>~~eee~~|||||||
||**CURRENT[A]**<br>~~ll~~|**ACIN 100V**<br>~~eee~~|1.2typ<br>~~eee~~|1.8typ<br>~~eee~~||||||
|||**ACIN 230V**<br>~~eee~~<br>~~a~~|0.6typ<br>~~eee~~<br>~~a~~|0.9typ<br>~~eee~~||||||
||**FREQUENCY[Hz]**<br>~~ll eee~~<br>~~Po~~<br>~~a~~<br>~~cc~~||50 / 60(45 - 66)<br>~~eee~~<br>~~cc~~<br>~~eeeeeeeeeeeee~~|||||||
||**EFFICIENCY[%]**<br>~~a~~<br>~~ll~~|**ACIN 100V**<br>~~cc~~<br>~~**a**~~<br>|84.0typ<br>~~cc~~<br>~~es~~<br>|85.0typ<br>~~ee~~<br>|87.0typ<br>~~ee~~|88.5typ<br>~~eee~~|87.0typ<br>~~eee~~|88.0typ<br>~~eee~~|88.5typ<br>~~eee~~|
|||**ACIN 230V**<br>~~cc~~<br>~~**a**~~<br>|86.0typ<br>~~cc~~<br>~~es~~<br>|87.5typ<br>~~ee~~<br>|89.0typ<br>~~ee~~|89.5typ<br>~~eee~~|89.0typ<br>~~eee~~|90.0typ<br>~~eee~~|90.5typ<br>~~eee~~|
||**POWER FACTOR**<br>**(Io=100%)**<br>~~a~~<br>~~ll ~~|**ACIN 100V**<br>~~cc~~<br>~~**a**~~<br>~~—~~|0.97typ<br>~~cc~~<br>~~es~~<br>~~—~~|0.97typ<br>~~ee ee eee eee eee~~<br>~~—~~||||||
|||**ACIN 230V**<br>~~**a**~~<br> ~~—~~|0.84typ<br>~~es~~<br>~~—~~|0.87typ<br>~~—~~||||||
||**INRUSH CURRENT[A]**<br>~~ll ~~<br>~~—=~~<br>~~[|~~|**ACIN 100V**<br>~~**a**~~<br> <br>~~—=~~<br>~~[|~~|15typ (Io=100%)at cold start<br>~~es~~<br>|||||||
|||**ACIN 230V**<br>~~—=~~<br>~~[|~~|35typ (Io=100%)at cold start|||||||
||**LEAKAGE CURRENT[mA]**<br>~~—=~~<br>~~[|~~<br>~~Po~~<br>~~a~~||0.4 / 0.75 max(ACIN 100V / 240V,60Hz,Io=100%,Accordingto IEC62368-1,and DEN-AN)<br>~~GO~~<br>|||||||
|**OUTPUT**|**VOLTAGE[V]**<br>~~OG~~<br>~~a~~||3.3<br>~~OG~~<br>|5<br>~~OG~~<br>|12<br>~~OG~~<br>|15<br>~~OG~~<br>~~GO~~<br>|24<br>~~OG~~<br>~~GO~~<br>|36<br>~~OG~~<br>|48|
||**CURRENT[A]**<br>~~a GG~~||30<br>~~GG~~|30<br>~~GG~~|13<br>~~GG~~|10<br>~~GO~~<br>~~GG~~|6.5<br>~~GO~~<br>~~GG~~|4.3<br>~~GG~~|3.3|
||**LINE REGULATION[mV]**<br>*3 <br>~~GG~~||20max<br>~~GG~~|20max<br>~~GG~~|48max<br>~~GG~~|60max<br>~~GG~~|96max<br>~~GG~~|144max<br>~~GG~~|192max|
||**LOAD REGULATION[mV]**<br>*3 <br>~~GG~~||40max<br>~~GG~~|40max<br>~~GG~~|100max<br>~~GG~~|120max<br>~~GG~~|150max<br>~~GG~~|240max<br>~~GG~~|240max|
||**RIPPLE[mVp-p]**<br>*4|**0 to +50**C <br>~~PO~~|80max<br>~~PO~~|80max<br>~~PO~~|120max<br>~~PO~~|120max<br>~~PO~~|120max<br>~~PO~~|150max<br>~~PO~~|150max|
|||**-20 to 0**C<br>~~a GO~~|140max<br>~~GO~~|140max<br>~~GO~~|160max<br>~~GO~~|160max<br>~~GO~~|160max<br>~~GO~~|200max<br>~~GO~~|200max|
|||**Io=0 to 15%** <br>~~a GG~~|300max<br>~~GG~~|300max<br>~~GG~~|360max<br>~~GG~~|500max<br>~~GG~~|500max<br>~~GG~~|500max<br>~~GG~~|500max|
||**RIPPLE NOISE[mVp-p]**<br>*4<br>~~ee~~|**0 to +50**C <br>~~a GO~~|120max<br>~~GO~~|120max<br>~~GO~~|150max<br>~~GO~~|150max<br>~~GO~~|150max<br>~~GO~~|250max<br>~~GO~~|250max|
|||**-20 to 0**C<br>~~a DG~~|160max<br>~~DG~~|160max<br>~~DG~~|180max<br>~~DG~~|180max<br>~~DG~~|180max<br>~~DG~~|300max<br>~~DG~~|300max|
|||**Io=0 to 15%** <br>~~a QD~~<br>~~ee~~|360max<br>~~QD~~<br>~~ee ee~~|360max<br>~~QD~~<br>~~ee ee~~|400max<br>~~QD~~<br>~~ee~~|600max<br>~~QD~~|600max<br>~~QD~~<br>~~eee~~|600max<br>~~QD~~<br>~~eee~~|600max<br>~~eee~~|
||**TEMPERATURE REGULATION[mV]**<br>~~ee~~|**0 to +50**C <br>~~ee~~|50max<br>~~ee ee~~|50max<br>~~ee ee~~|120max<br>~~ee~~|150max|240max<br>~~eee~~|360max<br>~~eee~~|480max<br>~~eee~~|
|||**-20 to +50**C <br>~~ee~~<br>~~a~~|60max<br>~~ee ee~~|60max<br>~~ee ee~~|150max<br>~~ee~~<br>~~G~~|180max|290max<br>~~eee~~|450max<br>~~eee~~|600max<br>~~eee~~|
||**DRIFT[mV]**<br>*5 <br>~~ee~~<br>~~po~~||20max<br>~~ee ee~~<br>~~po~~|20max<br>~~ee ee~~<br>~~po~~|48max<br>~~ee~~<br>~~po~~|60max<br>~~po~~|96max<br>~~eee~~<br>~~po~~|144max<br>~~eee~~<br>~~po~~|192max<br>~~eee~~|
||**START-UP TIME[ms]**<br>~~Po~~||120typ (ACIN 100V,Io=100%)|||||||
||**HOLD-UP TIME[ms]**<br>~~Po~~||20typ (ACIN 100V,Io=100%)|||||||
||**OUTPUT VOLTAGE ADJUSTMENT RANGE[V]**<br>~~po~~||2.85 to 3.63<br>~~po~~|4.00 to 5.50<br>~~po~~|10.00 to 13.20<br>~~po~~|13.20 to 18.00<br>~~po~~|19.20 to 27.00<br>~~po~~|28.80 to 39.60<br>~~po~~|39.00 to 53.00|
||**OUTPUT VOLTAGE SETTING[V]**<br>~~PT~~||3.30 to 3.40<br>~~PT~~|5.00 to 5.15<br>~~PT~~|12.00 to 12.48<br>~~PT~~|15.00 to 15.60<br>~~PT~~|24.00 to 24.96<br>~~PT~~|36.00 to 37.44<br>~~PT~~|48.00 to 49.92|
|**PROTECTION**<br>**CIRCUIT AND**<br>**OTHERS**|**OVERCURRENT PROTECTION**<br>~~Po~~||Works over 105% of ratingand recovers automatically|||||||
||**OVERVOLTAGE PROTECTION**<br>~~GD~~||4.00 to 5.25<br>~~GD~~|5.75 to 7.00<br>~~GD~~|15.00 to 18.00<br>~~GD~~|20.00 to 25.00<br>~~GD~~|30.00 to 37.00<br>~~GD~~|43.00 to 50.00<br>~~GD~~|58.00 to 67.00|
||**REMOTE SENSING**<br>~~Po~~||Notprovided|||||||
|**ISOLATION**|**INPUT-OUTPUT**<br>~~Po~~||3,000VAC 1minute,Cutoff current = 10mA,500VDC 100MWmin(At Room Temperature)|||||||
||**INPUT-FG**<br>~~Po~~||2,000VAC 1minute,Cutoff current = 10mA,500VDC 100MWmin(At Room Temperature)|||||||
||**OUTPUT-FG**<br>~~Po~~||500VAC 1minute,Cutoff current = 25mA,500VDC 100MWmin(At Room Temperature)|||||||
|**ENVIRONMENT**|**OPERATING TEMPERATURE,HUMID** *2 <br>~~Po~~||-20 to +70C,20 - 90%RH(Non condensing)|||||||
||**STORAGE TEMPERATURE,HUMID**<br>~~Po~~||-20 to +75C,20 - 90%RH(Non condensing)|||||||
||**VIBRATION**<br>~~Po~~||10 - 55Hz,19.6m/s2 (2G),3minutesperiod,60minutes each alongX,Y and Z axis|||||||
||**IMPACT**<br>~~Po~~||196.1m/s2 (20G),11ms,once each X,Y and Z axis|||||||
|**SAFETY AND**<br>**NOISE**<br>**REGULATIONS**|**AGENCY APPROVALS**<br>~~Po~~||UL62368-1,C-UL(equivalent to CAN/CSA-C22.2No.62368-1),EN62368-1,Complies with DEN-AN|||||||
||**CONDUCTED NOISE**<br>~~Po~~||Complies with CISPR11-B,CISPR32-B,EN55011-B,EN55032-B,FCC Part15-B,FCC Part18-B,VCCI-B|||||||
||**HARMONIC ATTENUATOR** *6 <br>~~Po~~||Complies with IEC61000-3-2(Class A)|||||||
|**OTHERS**|**CASE SIZE/WEIGHT**<br>~~Po~~||34X93X168mm[1.34×3.66×6.61 inches] (without terminal block) (WXHXD)/ 530gmax(with cover : 600gmax)|||||||
||**COOLING METHOD**<br>*2 <br>~~Po~~||Convection/Forced air(Refer to “Derating”)|||||||
- *1 The listed options may affect the published standard specifications. Please contact us for detailed product specifications.
- *2 Derating is required.Please contact us for DC input.
- *3 At low load conditions, the burst mode operation will start. To check load regulation, you will need to measure the characteristics at average mode with instruments.
- *4 This is the value that measured on measuring board with capacitor of 22mF at 150mm from output terminal.
Measured by 20MHz oscilloscope or Ripple-Noise meter
- (Equivalent to KEISOKU-GIKEN:RM104).
Ripple and ripple noise spec is change at Io=0 to 15% by burst operation.
- *5
- Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
- *6
- Please contact us about another class. When two or more units are operating it may not comply with the IEC61000-3-2. Please contact us for details.
- To meet the specification, do not operate overload condition.
-
- Parallel operation is not possible.
- Sound noise may be generated by power supply in case of pulse load.
**PDA-10**
January 29, 2026
## **PDA150F**
## **Block diagram**
**==> picture [450 x 560] intentionally omitted <==**
**----- Start of picture text -----**<br>
FUSE<br>AC250V 5A INRUSH<br>NOISE<br>AC IN 85 - 264VAC RECTIFIER CURRENT<br>FILTER<br>LIMIT<br>FG<br>BOOSTER CURRENT<br>INDUCTOR SENSING TRANSFORMER<br>RECTIFIER RECTIFIER<br>SWITCHING<br>AND DEVICE AND DC OUT<br>FILTER FILTER<br>SWITCHING<br>DEVICE<br>CURRENT<br>SENSING<br>OPTOCOUPLER<br>OVER VOLTAGE<br>CONTROL PROTECTION<br>OPTOCOUPLER<br>CONTROL CONTROL<br>Extemal size of option J1, N1 and V is different from standard model and refer to 8 option of instruction manual for details.<br>Cover<br>Cover name plate<br>Point ①<br>Output voltage 11.5±1.5 13.5±2 168<br>adjustment [0.45] [0.53] [6.61]<br>potentiometer<br>M4<br>+V<br>+V<br>-V<br>-V<br>FG ( )<br>AC(L) 2×M3<br>Mounting<br>AC(N) Hole<br>14.5[0.57]±1.5 TerminalCover 78[3.07]±0.5 [2.30]58.5<br>24±1.5 2×M3<br>[0.94] Name plate Mounting<br>Hole<br>* Tolerance : ±1<br>* Weight : 530g max (with cover : 600g max)<br>* PCB Material / thickness : FR-4 / 1.6mm [0.06]<br>* Chassis material : Aluminum<br>** Dimensions in mm, [ ]= inches Mounting torque : 0.6N ・ m max 139.5±0.5 9<br>* Screw tightening torque : M4 1.6N ・ m max [5.49] [0.35]<br>0.6 [0.02]<br>93<br>81 [3.19] 8.6 [0.34] [3.66]<br>[1.48]<br>10 [0.39] 37.5<br>10±1.5 [0.39]<br>[1.34] 37 [1.46]<br>19 34<br>[0.75]<br>**----- End of picture text -----**<br>
## **External view**
- *Extemal size of option J1, N1 and V is different from standard model and refer to 8 option of instruction manual for details.
- Please connect safety ground to the FG terminal on the unit.
- Keep drawing current per pin below 20A for TB1.
- Point 1 is the thermometry points. Please refer to Instruction Manual 4.
**PDA-11**
January 29, 2026
**AC-DC Power Supplies Enclosed Type PDA300F** ~~_~~
**Ordering information**
## R ALi; (D)C ~~E~~ UK
**==> picture [227 x 136] intentionally omitted <==**
**----- Start of picture text -----**<br>
- -<br> PD A 300 F O O<br>1 2 3 4 5 6<br>1Series name<br>Example recommended EMI/EMC filter<br>NAC-06-472 2Single output<br>3Output wattage<br>_ 4Universal input<br>5Output voltage<br>6Optional [*][1]<br>C: with Coating<br>G: LOW leakage current<br>N1 : with DIN rail<br>High voltage pulse noise type : NAP series<br>Low leakage current type : NAM series<br>*A higher current rating EMI/EMC filter<br>may be recommended in view of the<br>other devices that could be connected<br>in parallel with the power supply.<br>**----- End of picture text -----**<br>
For option details, refer to Instruction Manual 8.1.
|**MODEL**|**MODEL**|**PDA300F-3R3 **|**PDA300F-5**|**PDA300F-12**|**PDA300F-15**|**PDA300F-24**|**PDA300F-36**|**PDA300F-48**|
|---|---|---|---|---|---|---|---|---|
|**MAX OUTPUT WATTAGE[W]**<br>*2||**198**|**300**|**324**|**330**|**336**|**324**|**336**|
|**DC OUTPUT**<br>*2|**ACIN 100V**|**3.3V 60A**|**5V 60A**|**12V 27A**|**15V 22A**|**24V 14A**|**36V 9A**|**48V 7A**|
||<br>**ACIN 230V**<br>*3|**3.3V 60A**|**5V 60A**|**12V 27A**|**15V 22A**|**24V 14(16.5) A **|**36V 9A**|**48V 7A**|
## **SPECIFICATIONS**
|~~Pe~~|**MODEL**<br>~~Pe~~|**MODEL**<br>~~Pe~~|**PDA300F-3R3 **|**PDA300F-5**|**PDA300F-12**|**PDA300F-15**|**PDA300F-24**|**PDA300F-36**|**PDA300F-48**|
|---|---|---|---|---|---|---|---|---|---|
|**INPUT**<br>~~Pe~~|**VOLTAGE[VAC]**<br>*2 <br>~~Pe~~<br>~~eeeee~~||85 - 264 1f (Refer to Instruction Manual 1.1)<br>~~eee~~|||||||
||**CURRENT[A]**<br>~~ee~~|**ACIN 100V**<br>~~eee~~|2.9typ<br>~~eee~~|4.1typ<br>~~eee~~||||||
|||**ACIN 230V**<br>~~eee~~|1.4typ<br>~~eee~~|1.9typ<br>~~eee~~||||||
||**FREQUENCY[Hz]**<br>~~ee eee ~~||50 / 60(45-66)<br> ~~eee~~|||||||
||**EFFICIENCY[%]**<br>~~a ~~<br>~~el~~|**ACIN 100V**<br>~~ce~~|70.0typ<br>~~ce~~|75.0typ<br>~~ce~~|79.0typ<br>~~ce~~|80.5typ<br>~~ce~~|82.0typ<br>~~ce~~|81.0typ<br>~~ce~~|82.5typ|
|||**ACIN 230V**<br> ~~ce~~<br>~~eee~~|72.5typ<br>~~ce~~<br>~~eee~~|78.0typ<br>~~ce~~|82.0typ<br>~~ce~~|84.0typ<br>~~ce~~|84.5typ<br>~~ce~~|84.5typ<br>~~ce~~|86.0typ|
||**POWER FACTOR**<br>**(Io=100%)**<br>~~el~~<br>~~ee~~|**ACIN 100V**<br>~~eee~~|0.99typ<br>~~eee~~|||||||
|||**ACIN 230V**<br>~~eee~~<br>~~ee~~|0.95typ<br>~~eee~~|||||||
||**INRUSH CURRENT[A]** <br>~~el ~~<br>~~ee~~|**ACIN 100V**<br> ~~eee~~<br>~~ee~~|20typ (Io=100%)at cold start<br>~~eee~~|||||||
|||<br>**ACIN 230V**<br>~~ee~~|40typ (Io=100%)at cold start|||||||
||**LEAKAGE CURRENT[mA]**<br>~~ee ee~~||0.4 / 0.75 max(ACIN 100V / 240V,60Hz,Io=100%,Accordingto IEC62368-1,and DEN-AN)|||||||
|**OUTPUT**<br>~~**P**~~|**VOLTAGE[V]**<br>~~a~~||3.3<br>~~es~~|5<br>~~CC~~|12<br>~~CC~~|15<br>~~CC~~|24<br>~~CC~~|36<br>~~CC~~|48|
||**CURRENT[A]**<br>*3 <br>~~Pe~~|**ACIN 100V**<br>~~a~~<br>~~Pe~~|60<br>~~es~~<br>~~Pe~~|60<br>~~CC~~<br>~~Pe~~|27<br>~~CC~~<br>~~Pe~~|22<br>~~CC~~<br>~~Pe~~|14<br>~~CC~~<br>~~Pe~~|9<br>~~CC~~<br>~~Pe~~|7|
|||<br>**ACIN 230V**<br>~~a~~<br>~~Pe~~|60<br>~~es~~<br>~~Pe~~|60<br>~~CC~~<br>~~Pe~~|27<br>~~CC~~<br>~~Pe~~|22<br>~~CC~~<br>~~Pe~~|14(16.5)<br>~~CC~~<br>~~Pe~~|9<br>~~CC~~<br>~~Pe~~|7|
||**LINE REGULATION[mV]**<br>~~ee~~||20max<br>~~ee~~|20max<br>~~ee~~|48max<br>~~ee~~|60max<br>~~ee~~|96max<br>~~ee~~|144max<br>~~ee~~|192max|
||**LOAD REGULATION[mV]**<br>~~a~~||40max<br>~~a~~|40max<br>~~a~~|100max<br>~~a~~|120max<br>~~a~~|150max<br>~~a~~|150max<br>~~a~~|300max|
||**RIPPLE[mVp-p]**<br>*4 <br>~~a~~|**0 to +50**C<br>~~a~~|80max<br>~~a~~|80max<br>~~a~~|120max<br>~~a~~|120max<br>~~a~~|120max<br>~~a~~|150max<br>~~a~~|150max|
|||<br>**-20 to 0**C<br>~~a~~|140max<br>~~a~~|140max<br>~~a~~|160max<br>~~a~~|160max<br>~~a~~|160max<br>~~a~~|160max<br>~~a~~|400max|
||**RIPPLE**<br>**NOISE[mVp-p]**<br>*4<br>~~a~~<br>~~**P**e~~|**0 to +50**C<br>~~a~~|120max<br>~~a~~|120max<br>~~a~~|150max<br>~~a~~|150max<br>~~a~~|150max<br>~~a~~|200max<br>~~a~~|200max|
|||**-20 to 0**C<br>~~a~~|160max<br>~~a~~|160max<br>~~a~~|180max<br>~~a~~|180max<br>~~a~~|180max<br>~~a~~|240max<br>~~a~~|500max|
||**TEMPERATURE**<br>**REGULATION[mV]**<br>~~**P**e~~|**0 to +50**C|40max|50max|120max|150max|240max|360max|480max|
|||**-20 to +50**C|60max|75max|180max|180max|290max|440max|600max|
||**DRIFT[mV]**<br>*5 <br>~~**P**e~~||12max|20max<br>~~T~~|48max<br>~~T~~|60max<br>~~T~~|96max<br>~~T~~|144max<br>~~T~~|192max|
||**START-UP TIME[ms]**||300typ (ACIN 100V,Io=100%)|||||||
||**HOLD-UP TIME[ms]**||35typ (ACIN 100V,Io=100%)|||||||
||**OUTPUT VOLTAGE ADJUSTMENT RANGE[V]** <br>~~PT~~||2.64 to 3.96<br>~~PT~~|3.96 to 6.00<br>~~PT~~|8.25 to 13.20<br>~~PT~~|10.50 to 16.50<br>~~PT~~|16.50 to 26.40<br>~~PT~~|25.20 to 39.60<br>~~PT~~|38.40 to 56.00|
||**OUTPUT VOLTAGE SETTING[V]**<br>~~PT~~||3.30 to 3.40<br>~~PT~~|5.00 to 5.15<br>~~PT~~|12.00 to 12.48<br>~~PT~~|15.00 to 15.60<br>~~PT~~|24.00 to 24.96<br>~~PT~~|36.00 to 37.44<br>~~PT~~|48.00 to 49.92|
|**PROTECTION**<br>**CIRCUIT AND**<br>**OTHERS**|**OVERCURRENT PROTECTION**||Works over 105% of ratingand recovers automatically|||||||
||**OVERVOLTAGE PROTECTION[V]**<br>~~PT~~||4.30 to 6.30<br>~~PT~~|6.50 to 8.00<br>~~PT~~|14.40 to 18.60<br>~~PT~~|18.00 to 23.30<br>~~PT~~|28.80 to 37.20<br>~~PT~~|43.20 to 54.00<br>~~PT~~|57.60 to 80.00|
||**REMOTE SENSING**||Provided|||||||
||**REMOTE ON/OFF**<br>~~Po~~||Provided|||||||
|**ISOLATION**|**INPUT-OUTPUT-RC**<br>~~Po~~||3,000VAC 1minute,Cutoff current = 10mA,500VDC 100MWmin(At Room Temperature)|||||||
||**INPUT-FG**<br>~~Po~~||2,000VAC 1minute,Cutoff current = 10mA,500VDC 100MWmin(At Room Temperature)|||||||
||**OUTPUT**・**RC**・**AUX-FG**<br>~~Po~~||500VAC 1minute,Cutoff current = 100mA,500VDC 100MWmin(At Room Temperature)|||||||
||**OUTPUT-RC-AUX**<br>~~Po~~||500VAC 1minute,Cutoff current = 100mA,500VDC 100MWmin(At Room Temperature)|||||||
|**ENVIRONMENT**|**OPERATING TEMP.,HUMID.AND ALTITUDE** *2 <br>~~Po~~||-20 to +70C (Refer to “Derating”),20 - 90%RH(Non condensing)|||||||
||**STORAGE TEMP.,HUMID.AND ALTITUDE**<br>~~Po~~||-20 to +75C,20 - 90%RH(Non condensing)|||||||
||**VIBRATION**<br>~~Po~~||10 - 55Hz,19.6m/s2 (2G),3minutesperiod,60minutes each alongX,Y and Z axis|||||||
||**IMPACT**<br>~~Po~~||196.1m/s2 (20G),11ms,once each X,Y and Z axis|||||||
|**SAFETY AND**<br>**NOISE**<br>**REGULATIONS**|**AGENCY APPROVALS(At only AC input)** <br>~~Po~~||UL62368-1,C-UL(equivalent to CAN/CSA-C22.2No.62368-1),EN62368-1,Complies with DEN-AN|||||||
||**CONDUCTED NOISE**<br>~~Po~~||Complies with CISPR11-B,CISPR32-B,EN55011-B,EN55032-B,FCC Part15-B,FCC Part18-B,VCCI-B|||||||
||**HARMONIC ATTENUATOR**<br>*6 <br>~~Po~~||Complies with IEC61000-3-2(Class A)|||||||
|**OTHERS**|**CASE SIZE/WEIGHT**<br>~~Po~~||102†42†170mm[4.02†1.65†6.69 inches] (without terminal block and screw) (W†H†D)/1.0kgmax|||||||
||**COOLING METHOD**<br>*2 <br>~~Po~~||Forced cooling (internal fan)|||||||
- *1 The listed options may affect the published standard specifications. Please contact us for detailed product specifications.
- *2 Derating is required. Please contact us for DC input.
- *3 ( ) means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manual in detail.
- *4 This is the value measured on measuring board with capacitor of 22μF within 150mm from output terminal.
- *5 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25ª, with the input voltage held constant at the rated input/output.
- *6 Please contact us about another class. When two or more units are operating it may not comply with the IEC61000-3-2. Please contact us for details.
- * To meet the specification, do not operate overload condition.
- Sound noise may be generated by power supply in case of pulse load.
- Measured by 20MHz Oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN : RM-104).
**PDA-12**
January 29, 2026
## **PDA300F**
## **Block diagram**
**==> picture [469 x 223] intentionally omitted <==**
**----- Start of picture text -----**<br>
AC IN FUSE NOISE INRUSH<br>85 - 264VAC FILTER RECTIFIER CURRENT<br>250V10A LIMIT<br>FG<br>BOOSTER CURRENT TRANSFORMER<br>INDUCTOR SENSING RECTIFIER SWITCHING RECTIFIER<br>AND DEVICE AND DC OUT<br>FILTER FILTER<br>SWITCHING THERMAL OPTOCOUPLER ±M<br>DEVICE PROTECTION<br>CURRENT OVER VOLTAGE<br>SENSING PROTECTION<br>OPTOCOUPLER<br>VOLTAGE<br>CONTROL SENSING CONTROL CONTROL ±S(REMOTE SENSING)<br>RC(REMOTE ON / OFF)<br>MASTER VB(VOLTAGE BALANCE)<br>SLAVE<br>CONTROL CB(CURRENT BALANCE)<br>TRANSFORMER<br>INTERNAL<br>REGULATOR FAN ALARM PG(POWER GOOD)<br>AUX(12 V 0.1A)<br>**----- End of picture text -----**<br>
## **External view**
**==> picture [450 x 299] intentionally omitted <==**
**----- Start of picture text -----**<br>
4 × M4<br>Mounting Hole<br>54 74±0.5<br>M4 [2.13] [2.91]<br>Cover name plate 2 × M4<br>13.5 Terminal Cover 20.5±2 Mounting Hole<br>[0.53] [0.81] (Bottom side)<br>AC(L)<br>AC(N)<br>FG ( )<br>-V<br>-V<br>+V<br>+V<br>M4 CN3<br>15 CN2 Name plate 28.5 64±0.5<br>[0.59] CN1<br>29.4 Output voltage [1.12] [2.52] 170 4±2<br>[1.16] adjustable [6.69] [0.16]<br>potentiometer<br>AIR FLO<br> Dimensions in mm, [ ] = inches<br> Tolerance : ± 1 [ ± 0.04]<br> Weight : 1.0kg max<br> PCB Material/thickness : FR-4/1.6mm [0.06]<br> Chassis material : Aluminum<br>• m max<br>12 [0.47]<br>[0.79]<br>20±0.5<br>6 [0.24]<br>7 [0.28]<br>0<br>1 [0.39] 89.<br>68. [0.34] 4 [1.96]<br>CN3 886. [3.42]<br>CN2 23.5 [0.93] 12 [0.47] 102 [4.02]<br>CN1 31125. [0.53][0.47] 50.5 [1.99]<br>V.ADJ H<br>42 [1.65]<br>**----- End of picture text -----**<br>
- Dimensions in mm, [ ] = inches
- Tolerance : ± 1 [ ± 0.04]
- Weight : 1.0kg max
- PCB Material/thickness : FR-4/1.6mm [0.06]
- Chassis material : Aluminum
- Mounting torque : 1.2N • m max
- Screw tightening torque : M4 : 1.6N • m max
- The housing for the remote sensing unused is mounted on CN1
- Please connect safety ground to FG terminal on the unit
**PDA-13**
January 29, 2026
|**PDA600F**<br>**AC-DC Power Supplies Enclosed Type**<br>**PD**<br>**A**<br>**600**<br>**F**<br>**-**O **-**O<br>**Ordering information**<br>1<br>2<br>3<br>4<br>5<br>6<br>~~|~~<br>~~|~~<br>~~a~~|**PDA600F**<br>**AC-DC Power Supplies Enclosed Type**<br>**PD**<br>**A**<br>**600**<br>**F**<br>**-**O **-**O<br>**Ordering information**<br>1<br>2<br>3<br>4<br>5<br>6<br>~~|~~<br>~~|~~<br>~~a~~|**PDA600F**<br>**AC-DC Power Supplies Enclosed Type**<br>**PD**<br>**A**<br>**600**<br>**F**<br>**-**O **-**O<br>**Ordering information**<br>1<br>2<br>3<br>4<br>5<br>6<br>~~|~~<br>~~|~~<br>~~a~~|**PDA600F**<br>**AC-DC Power Supplies Enclosed Type**<br>**PD**<br>**A**<br>**600**<br>**F**<br>**-**O **-**O<br>**Ordering information**<br>1<br>2<br>3<br>4<br>5<br>6<br>~~|~~<br>~~|~~<br>~~a~~|**PDA600F**<br>**AC-DC Power Supplies Enclosed Type**<br>**PD**<br>**A**<br>**600**<br>**F**<br>**-**O **-**O<br>**Ordering information**<br>1<br>2<br>3<br>4<br>5<br>6<br>~~|~~<br>~~|~~<br>~~a~~|**PDA600F**<br>**AC-DC Power Supplies Enclosed Type**<br>**PD**<br>**A**<br>**600**<br>**F**<br>**-**O **-**O<br>**Ordering information**<br>1<br>2<br>3<br>4<br>5<br>6<br>~~|~~<br>~~|~~<br>~~a~~|**PDA600F**<br>**AC-DC Power Supplies Enclosed Type**<br>**PD**<br>**A**<br>**600**<br>**F**<br>**-**O **-**O<br>**Ordering information**<br>1<br>2<br>3<br>4<br>5<br>6<br>~~|~~<br>~~|~~<br>~~a~~|
|---|---|---|---|---|---|---|
|R<br>ALi(D)C~~€~~ ea<br>c||||||1Series name<br>2Single output<br>3Output wattage<br>4Universal input<br>**Example recommended EMI/EMC filter**<br>**NAC-10-472**<br>~~|~~<br>~~=~~|
|||||||5 Output voltage|
|||||||6 Optional*1|
||||||||C: with Coating<br>G: LOW leakage current|
||re|Oe ,||||*<br>A higher current rating EMI/EMC filter<br>may be recommended in view of the<br>other devices that could be connected<br>High voltage pulse noise type : NAP series<br>Low leakage current type : NAM series|
|||||||in parallel with the power supply.|
|||||||For option details, refer to|
|||||||Instruction Manual 8.1.|
|**MODEL**||**PDA600F-3R3 **|**PDA600F-5**|**PDA600F-12**||**PDA600F-15**<br>**PDA600F-24**<br>**PDA600F-36**<br>**PDA600F-48**|
|**MAX OUTPUT WATTAGE[W]**|*2|**396**|**600**|**636**||**645**<br>**648**<br>**648**<br>**624**|
|**DC OUTPUT**<br>*2|**ACIN 100V**<br>**ACIN 230V**<br>*3|**3.3V 120A**<br> **3.3V 120A**|**5V 120A**<br>**5V 120A**|**12V 53A**<br>**12V 53A**||**15V 43A**<br>**24V 27A**<br>**36V 18A**<br>**48V 13A**<br>**15V 43A**<br>**24V 27(31)A**<br>**36V 18A**<br>**48V 13A**|
## **SPECIFICATIONS**
|~~Po~~|**MODEL**<br>~~Po~~<br>~~|~~|**MODEL**<br>~~Po~~<br>~~|~~|**PDA600F-3R3 **<br>~~|~~<br>~~|~~|**PDA600F-5**<br>~~|~~<br>~~|~~|**PDA600F-12**<br>~~|~~<br>~~|~~|**PDA600F-15**<br>~~|~~|**PDA600F-24**<br>~~es~~|**PDA600F-36**<br>~~ee~~|**PDA600F-48**|
|---|---|---|---|---|---|---|---|---|---|
|**INPUT**<br>~~Po~~<br>~~Po~~|**VOLTAGE[VAC]**<br>*2 <br>~~Po~~<br>~~|~~||85 - 264 1f (Refer to Instruction Manual 1.1)<br>~~es~~<br>~~ee~~<br>~~|~~<br>~~|~~<br>~~|~~<br>~~|~~|||||||
||**CURRENT[A]**|**ACIN 100V**|5.2typ|7.9typ||||||
|||**ACIN 230V**|2.5typ|3.4typ||||||
||**FREQUENCY[Hz]**<br>~~Po~~||50 / 60(45-66)<br>~~ee~~<br>~~ee~~<br>~~|~~<br>~~ee~~|||||||
||**EFFICIENCY[%]**<br>~~Po~~|**ACIN 100V**<br>~~es~~|73.5typ<br>~~es~~<br>~~ee~~|78.5typ<br>~~|~~<br>~~es~~|83.0typ<br>~~|~~|83.5typ<br>~~ee~~|85.5typ<br>~~ee~~|84.5typ|86.0typ|
|||**ACIN 230V**|75.5typ<br>~~ee~~|81.0typ<br>~~|~~|85.5typ<br>~~|~~|86.5typ<br>~~ee~~|88.0typ<br>~~ee~~|87.0typ|89.0typ|
||**POWER FACTOR**<br>**(Io=100%)**<br>~~Po~~|**ACIN 100V**|0.98typ<br>~~ee~~<br>~~ee~~|||||||
|||**ACIN 230V**|0.95typ|||||||
||**INRUSH CURRENT[A]**|**ACIN 100V**|20/40typ (Io=100%) (Primary/ Secondaryinrush current) (More than 3 sec. to re-start)|||||||
|||<br>**ACIN 230V**|40/40typ (Io=100%) (Primary/ Secondaryinrush current) (More than 3 sec. to re-start)|||||||
||**LEAKAGE CURRENT[mA]**<br>~~a~~||0.4 / 0.75 max(ACIN 100V / 240V,60Hz,Io=100%,Accordingto IEC62368-1,and DEN-AN)<br>~~|~~<br>~~|~~<br>~~|~~|||||||
|**OUTPUT**|**VOLTAGE[V]**<br>~~a~~||3.3|5|12<br>~~|~~|15<br>~~|~~<br>~~|~~|24<br>~~|~~<br>~~|~~|36<br>~~|~~|48|
||**CURRENT[A]**<br>*3 <br>~~a~~<br>~~Bs~~|**ACIN 100V**<br>~~Bs~~|120<br>~~Bs~~|120<br>~~Bs~~|53<br>~~|~~<br>~~Bs~~|43<br>~~|~~<br>~~|~~<br>~~Bs~~|27<br>~~|~~<br>~~|~~<br>~~Bs~~|18<br>~~|~~<br>~~Bs~~|13|
|||<br>**ACIN 230V**<br>~~Bs~~|120<br>~~Bs~~|120<br>~~Bs~~|53<br>~~Bs~~|43<br>~~Bs~~|27(31)<br>~~Bs~~|18<br>~~Bs~~|13|
||**LINE REGULATION[mV]**<br>~~a~~<br>~~cee~~||20max|20max|48max|60max<br>~~|~~|96max<br>~~|~~<br>~~|~~|144max<br>~~|~~|192max|
||**LOAD REGULATION[mV]**<br>~~a~~<br>~~cee~~||40max<br>~~cere~~|40max<br>~~cee~~|100max<br>~~eee~~|120max<br>~~|~~<br>~~eee~~|150max<br>~~|~~<br>~~|~~<br>~~eee~~|150max<br>~~|~~|300max|
||**RIPPLE[mVp-p]**<br>*4 <br>~~a~~<br>~~cee~~<br>~~————————~~|**0 to +50**C<br>~~e~~|80max<br>~~cere~~|80max<br>~~cee~~|120max<br>~~eee~~|120max<br>~~|~~<br>~~eee~~|120max<br>~~|~~<br>~~|~~<br>~~eee~~|150max<br>~~|~~|150max|
|||<br>**-20 to 0**C<br>~~e~~<br>~~————————~~|140max<br>~~cere~~<br>~~————————~~|140max<br>~~cee~~<br>~~————————~~|160max<br>~~eee~~|160max<br>~~|~~<br>~~eee~~|160max<br>~~|~~<br>~~eee~~<br>~~a~~|160max|400max|
||**RIPPLE**<br>**NOISE[mVp-p]**<br>*4<br>~~cee~~<br>~~————————~~|**0 to +50**C<br>~~e~~<br>~~————————~~|120max<br>~~cere~~<br>~~————————~~|120max<br>~~cee ~~<br>~~————————~~|150max<br> ~~eee ~~<br>~~a~~|150max<br>~~|~~<br> ~~eee ~~<br>~~a~~|150max<br>~~|~~<br> ~~eee~~<br>~~a~~|200max|200max|
|||**-20 to 0**C<br>~~————————~~<br>~~a GO~~|160max<br>~~————————~~<br>~~GO~~|160max<br>~~————————~~<br>~~GO~~|180max<br>~~GO~~|180max<br>~~GO~~|180max<br>~~a~~<br>~~GO~~|240max<br>~~GO~~|500max|
||**TEMPERATURE**<br>**REGULATION[mV]**<br>~~————————~~<br>~~a~~|**0 to +50**C<br>~~————————~~|40max<br>~~————————~~|50max<br>~~————————~~|120max|150max|240max<br>~~a~~|360max|480max|
|||**-20 to +50**C|60max|75max<br>~~|~~|180max<br>~~|~~<br>~~|~~|180max<br>~~|~~<br>~~|~~|290max<br>~~|~~<br>~~|~~|440max<br>~~|~~|600max|
||**DRIFT[mV]**<br>*5 <br>~~a~~||12max|20max<br>~~|~~|48max<br>~~|~~<br>~~|~~|60max<br>~~|~~<br>~~|~~|96max<br>~~|~~<br>~~|~~|144max<br>~~|~~|192max|
||**START-UP TIME[ms]**<br>~~a~~||400typ (ACIN 100V,Io=100%)<br>~~|~~<br>~~|~~<br>~~|~~<br>~~|~~|||||||
||**HOLD-UP TIME[ms]**||35typ (ACIN 100V,Io=100%)|||||||
||**OUTPUT VOLTAGE ADJUSTMENT RANGE[V]**||2.64 to 3.96|3.96 to 6.00<br>~~[|~~|8.25 to 13.20<br>~~[|~~<br>~~[|~~|10.50 to 16.50<br>~~|~~<br>~~[|~~|16.50 to 26.40<br>~~[|~~<br>~~|~~|25.20 to 39.60<br>~~[|~~|38.40 to 56.00|
||**OUTPUT VOLTAGE SETTING[V]**<br>~~Po~~||3.30 to 3.40<br>~~es~~|5.00 to 5.15<br>~~[|~~<br>~~es~~|12.00 to 12.48<br>~~[|~~<br>~~[|~~|15.00 to 15.60<br>~~|~~<br>~~[|~~|24.00 to 24.96<br>~~[|~~<br>~~|~~|36.00 to 37.44<br>~~[|~~|48.00 to 49.92|
|**PROTECTION**<br>**CIRCUIT AND**<br>**OTHERS**|**OVERCURRENT PROTECTION**<br>~~Po~~||Works over 105% of ratingand recovers automatically<br>~~[|~~<br>~~|~~<br>~~[|~~<br>~~[|~~|||||||
||**OVERVOLTAGE PROTECTION[V]**<br>~~po~~||4.30 to 6.30<br>~~po~~|6.50 to 8.00<br>~~po~~|14.40 to 18.60<br>~~po~~|18.00 to 23.30<br>~~po~~|28.80 to 37.20<br>~~po~~|43.20 to 54.00<br>~~po~~|57.60 to 80.00|
||**REMOTE SENSING**<br>~~po~~||Provided|||||||
||**REMOTE ON/OFF**<br>~~Po~~||Provided|||||||
|**ISOLATION**|**INPUT-OUTPUT-RC**<br>~~Po~~||3,000VAC 1minute,Cutoff current = 10mA,500VDC 100MWmin(At Room Temperature)|||||||
||**INPUT-FG**<br>~~Po~~||2,000VAC 1minute,Cutoff current = 10mA,500VDC 100MWmin(At Room Temperature)|||||||
||**OUTPUT-RC-AUX-FG**<br>~~po~~||500VAC 1minute,Cutoff current = 100mA,500VDC 100MWmin(At Room Temperature)|||||||
||**OUTPUT-RC-AUX**<br>~~Po~~||500VAC 1minute,Cutoff current = 100mA,500VDC 100MWmin(At Room Temperature)|||||||
|**ENVIRONMENT**|**OPERATING TEMP.,HUMID.AND ALTITUDE** *2 <br>~~po~~||-20 to +70C (Refer to “Derating”),20 - 90%RH(Non condensing)|||||||
||**STORAGE TEMP.,HUMID.AND ALTITUDE**<br>~~po~~||-20 to +75C,20 - 90%RH(Non condensing)|||||||
||**VIBRATION**<br>~~po~~||10 - 55Hz,19.6m/s2 (2G),3minutesperiod,60minutes each alongX,Y and Z axis|||||||
||**IMPACT**<br>~~Po~~||196.1m/s2 (20G),11ms,once each X,Y and Z axis|||||||
|**SAFETY AND**<br>**NOISE**<br>**REGULATIONS**|**AGENCY APPROVALS(At only AC input)** <br>~~Po~~||UL62368-1,C-UL(equivalent to CAN/CSA-C22.2No.62368-1),EN62368-1,Complies with DEN-AN|||||||
||**CONDUCTED NOISE**<br>~~po~~||Complies with CISPR11-B,CISPR32-B,EN55011-B,EN55032-B,FCC Part15-B,FCC Part18-B,VCCI-B|||||||
||**HARMONIC ATTENUATOR**<br>*6 <br>~~Po~~||Complies with IEC61000-3-2(Class A)|||||||
|**OTHERS**|**CASE SIZE/WEIGHT**<br>~~Po~~||120†61†190mm[4.72†2.4†7.48 inches] (without terminal block and screw) (W†H†D)/1.6kgmax|||||||
||**COOLING METHOD**<br>*2 <br>~~Po~~||Forced cooling (internal fan)|||||||
- *1 The listed options may affect the published standard specifications. Please contact us for detailed product specifications.
- *2 Derating is required. Please contact us for DC input.
- *3 ( ) means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manual in detail.
- *4 This is the value measured on measuring board with capacitor of 22μF within 150mm from output terminal.
- *5 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25ª, with the input voltage held constant at the rated input/output.
- *6 Please contact us about another class. When two or more units are operating it may not comply with the IEC61000-3-2. Please contact us for details.
- * To meet the specification, do not operate overload condition.
- Sound noise may be generated by power supply in case of pulse load.
- Measured by 20MHz Oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN : RM-104).
**PDA-14**
January 29, 2026
## **PDA600F**
## **Block diagram**
**==> picture [469 x 223] intentionally omitted <==**
**----- Start of picture text -----**<br>
FUSE<br>AC IN NOISE<br>85 - 264VAC FILTER RECTIFIER<br>250V16A<br>FG<br>BOOSTER CURRENT TRANSFORMER<br>INDUCTOR SENSING INRUSH RECTIFIER SWITCHING RECTIFIER<br>CURRENT AND DEVICE AND DC OUT<br>LIMIT FILTER FILTER<br>SWITCHING THERMAL OPTOCOUPLER ±M<br>DEVICE CURRENT PROTECTION OVER VOLTAGE<br>SENSING PROTECTION<br>VOLTAGE OPTOCOUPLER<br>CONTROL<br>SENSING CONTROL CONTROL ±S(REMOTE SENSING)<br>RC(REMOTE ON / OFF)<br>MASTER VB(VOLTAGE BALANCE)<br>SLAVE<br>CONTROL CB(CURRENT BALANCE)<br>TRANSFORMER<br>INTERNAL<br>REGULATOR FAN ALARM PG(POWER GOOD)<br>AUX(12 V 0.1A)<br>**----- End of picture text -----**<br>
## **External view**
**==> picture [457 x 273] intentionally omitted <==**
**----- Start of picture text -----**<br>
Cover name plate 4 × M4<br>Terminal Cover 17.5±2 Mounting Hole<br>13.6 M4 [0.00] Name plate (Bottom side)<br>[0.00]<br>AC(L)<br>AC(N)<br>FG ( )<br>-V CN3<br>-V CN2<br>+V CN1<br>+V<br>17.8 M5 Output voltageadjustable 21.5±2 24 150±0.5<br>[0.00] potentiometer [0.00] [0.00] [0.00] 3±2<br>48 190 [0.00]<br>[0.00] [0.00]<br>61 8 × M4<br>[0.00] Mounting Hole<br>(both sides)<br>AIR FLO<br>* Dimensions in mm, [ ] = inches<br>* Tolerance : ± 1 [ ± 0.04]<br>* Weight : 1.6kg max 24 150±0.5<br>* PCB Material/thickness : FR-4/1.6mm [0.06] [0.00] [0.00]<br>5<br>[0.00] 6.9 [0.00]<br>10 [0.00]<br>(L) AC<br>11 [0.00]<br>(N) AC FG( 52.8 [0.00]<br> ) 8.6 [0.00]<br>CN3 92.5 [0.00] ±0.5<br>CN2 27.5 [0.00] 14 [0.00] [0.00] 120 [0.00]<br>CN1 65. 100<br>1 [0.00]<br>14 [0.00]<br>V.ADJ<br>0.5<br>±<br>38<br>12.5<br>**----- End of picture text -----**<br>
- Chassis material : Aluminum
- Mounting torque : 1.2N • m max
- Screw tightening torque
- M4 : 1.6N • m max
- M5 : 2.5N • m max
- The housing for the remote sensing unused is mounted on CN1
- Please connect safety ground to FG terminal on the unit
**PDA-15**
January 29, 2026
## **PDA-series**
## **Terminal Blocks**
* The following information covers PDA300F - 600F. Please see External View for PDA15F - 150F.
## ¿ PDA300F
**==> picture [192 x 116] intentionally omitted <==**
**----- Start of picture text -----**<br>
9 8 7 6<br>CN3 CN2 CN1<br> H<br>V.ADJ<br>1 2 3 4 5<br>**----- End of picture text -----**<br>
**==> picture [203 x 152] intentionally omitted <==**
**----- Start of picture text -----**<br>
¿ PDA600F<br>9 8 7 6<br>CN3 CN2 CN1 V.ADJ<br>FG<br>AC AC<br>(L) (N)<br>1 2 3 4 5<br>**----- End of picture text -----**<br>
1 AC (L) Input Terminals 85 - 264VAC f 45 - 66Hz 2 AC (N)
3 Frame ground (M4 )
4 -Output
- 5 +Output
- 6 Output voltage adjustable potentiometer
- 7 CN1
- 8 CN2 Connectors
9 CN3
## ¿ PDA300F, 600F Pin Configuration
**==> picture [88 x 36] intentionally omitted <==**
**----- Start of picture text -----**<br>
PCB<br>8 2 10 2 10 2<br>7 1 9 1 9 1<br>CN3 CN2 CN1<br>**----- End of picture text -----**<br>
Pin Configuration and Functions of CN1 and CN2
|Pin No.|Function|
|---|---|
|1<br>|+M<br>:Self sensingterminal.(Do not wire for external connection.)|
|2<br><br>3<br>-|+S<br>: +Sensing<br>M<br>:Self sensingterminal(Do not wire for external connection)|
|4<br>-|..<br>S<br>: -Sensing|
|5<br>|VB<br>: Voltage balance|
|6<br>|CB<br>: Current balance|
|7<br>|TRM<br>: Adjustment of output voltage|
|8<br>-|S<br>: -Sensing|
|9<br>|RC2<br>: Remote ON/OFF|
|10<br>|RCG<br>: Remote ON/OFF(GND)|
Pin Configuration and Functions of CN3
|Pin No.|Pin No.|Function|Function|Function|
|---|---|---|---|---|
|1<br>-||S<br>: -Sensing|||
|2<br>-||S<br>: -Sensing|||
|3<br>||AUX<br>: Auxiliaryoutput<br>(12V 0.1A)|||
|4<br>||RC1<br>: Remote ON/OFF|||
|5<br>||AUXG<br>: Auxiliaryoutput(GND)|||
|6<br>||N.C.<br>: No connection|||
|7<br>||PG<br>: Alarm|||
|8<br>||PGG<br>: Alarm(GND)|||
|*Common signs among CN1, CN2 and CN3 such as -S represent the same<br>potential.<br>Matching connecters and terminals on CN1, CN2 and CN3|||||
|Connector||Housing|Terminal|Mfr.|
|CN1<br>CN2|S10B-PHDS|S<br>PHDR-10VS<br> <br> <br>S<br>PHDR-08VS|Reel<br>: SPHD-002T-P0.5<br>Loose : BPHD-001T-P0.5|J.S.T.|
|CN3|S8B-PHDS||||
**PDA-16**
January 29, 2026
## **PDA-series**
## **Assembling and Installation Method**
## Installation method
- ¡ Do not insert a screw more than 6mm from the outside of a power supply to keep enough insulation distance between the screw and internal components.
## ¿ PDA15F, PDA30F, PDA50F, PDA100F, PDA150F
- ¡ For the metal chassis, keep the distance d1 for isolation between component and metal chassis.
- The d1 dimension is the distance required for insulation and does not satisfy cooling conditions. For cooling conditions, please refer to “Derating” and section 3 of the instruction manual.
- ¡ If you use two or more power supplies side by side, please keep a sufficient distance between them to allow enough air ventilation.
- ¡ Ambient temperature around each power supply should not exceed the temperature range shown in “Derating”.
**==> picture [204 x 329] intentionally omitted <==**
**----- Start of picture text -----**<br>
Chassis of<br>Chassis of<br>PDA series<br>customer system<br>Mounting Screw<br>6mm max<br>d1 d1:3mm min<br>A B C<br>Normal mounting<br>**----- End of picture text -----**<br>
## ¿ PDA300F, PDA600F
- ¡ If you need to secure a power supply by screws, securely fix it, taking into consideration of its weight. You can install it in any direction.
**==> picture [428 x 130] intentionally omitted <==**
**----- Start of picture text -----**<br>
Fixed screw<br>Fixed screw<br>Terminal<br>block<br>Fixed screw Fixed screw Fixed screw<br>Fixed screw<br>(a) (b) Not allowed (c) (d) Only for PDA600F<br>Terminal block Terminal block Terminal block<br>**----- End of picture text -----**<br>
- ¡ If you use a power supply in a dusty environment, it can cause a failure. Please consider taking such countermeasures as installing an air filter near the suction area of the system to prevent a failure.
- ¡ The power supplies have a built-in forced cooling fan. Do not block ventilation at the suction side and its opposite side.
**==> picture [267 x 70] intentionally omitted <==**
**----- Start of picture text -----**<br>
d1,d2 : 30mm min<br>d3 Terminal d3 (Only for PDA300F) : 30mm min<br>block<br>d1 d2<br>**----- End of picture text -----**<br>
**PDA-17**
January 29, 2026
## **PDA-series**
## **Derating**
¿ Derating curve for input voltage PDA15F, PDA30F
**==> picture [119 x 106] intentionally omitted <==**
**----- Start of picture text -----**<br>
[%]<br>100<br>80<br>85 90<br>AC input voltage [VAC]<br>Load factor<br>**----- End of picture text -----**<br>
## ¿ PDA15F
Ambient temperature derating curve (Reference value)
**==> picture [224 x 449] intentionally omitted <==**
**----- Start of picture text -----**<br>
(1)A mounting (2)A-C mounting<br>(1)B,C mounting<br>100<br>80<br>75<br>60<br>(1)Convection<br>40 (2)Forced air (0.5m [3] / min)<br>20<br>15<br>0<br>-20 -10 0 10 20 30 40 50 55 60 70<br>Ambient temperature [ C ]<br> PDA30F<br>Ambient temperature derating curve<br>(Reference value)<br>(1)A mounting (2)A-C mounting<br>(1)C mounting (1)B mounting<br>100<br>80<br>75<br>60<br>(1)Convection<br>40 (2)Forced air (0.5m [3] / min)<br>20<br>15<br>0<br>-20 -10 0 10 20 30 40 45 50 55 60 70<br>Ambient temperature [ C ]<br> PDA50F-3R3, -5<br>Ambient temperature derating curve<br>(Reference value)<br>(2)A-C mounting<br>(1)B,C mounting (1)A mounting<br>100<br>80<br>60<br>50 (1)Convection<br>40 (2)Forced air (0.5m [3] / min)<br>20<br>15<br>0<br>-20 -10 0 10 20 30 40 45 50 60 70<br>Ambient temperature [ C ]<br>Load factor [%]<br>Load factor [%]<br>Load factor [%]<br>**----- End of picture text -----**<br>
## ¿ PDA30F
Ambient temperature derating curve (Reference value)
## ¿ PDA50F-3R3, -5
Ambient temperature derating curve (Reference value)
## ¿ PDA15F-□-N
Ambient temperature derating curve (Reference value)
**==> picture [223 x 449] intentionally omitted <==**
**----- Start of picture text -----**<br>
(1)A mounting (2)A-C mounting<br>(1)B,C mounting<br>100<br>80<br>75<br>70<br>60<br>50 (1)Convection<br>40 (2)Forced air (0.5m [3] / min)<br>20<br>15<br>0<br>-20 -10 0 10 20 30 40 45 50 60 70<br>Ambient temperature [ C ]<br> PDA30F-□-N □-N -N<br>Ambient temperature derating curve<br>(Reference value)<br>(1)A mounting (2)A-C mounting<br>(1)C mounting (1)B mounting<br>100<br>80<br>70<br>60<br>50 (1)Convection<br>40 (2)Forced air (0.5m [3] / min)<br>20<br>15<br>0<br>-20 -10 0 10 20 30 40 50 60 70<br>Ambient temperature [ C ]<br> PDA50F-3R3-N, -5-N<br>Ambient temperature derating curve<br>(Reference value)<br>(2)A-C mounting<br>(1)C mounting (1)A,B mounting<br>100<br>80<br>60<br>(1)Convection<br>40 (2)Forced air (0.5m [3] / min)<br>20<br>15<br>0<br>-20 -10 0 10 20 30 35 40 50 60 70<br>Ambient temperature [ C ]<br>Load factor [%]<br>Load factor [%]<br>Load factor [%]<br>**----- End of picture text -----**<br>
## ¿ PDA30F-□-N □-N -N
Ambient temperature derating curve (Reference value)
## ¿ PDA50F-3R3-N, -5-N
Ambient temperature derating curve (Reference value)
**PDA-18**
January 29, 2026
## **PDA-series**
## **Derating**
- ¿ PDA50F-12, -15, -24, -36, -48 Ambient temperature derating curve (Reference value)
**==> picture [221 x 109] intentionally omitted <==**
**----- Start of picture text -----**<br>
(2)A-C mounting<br>(1)B,C mounting (1)A mounting<br>100<br>80<br>60<br>50 (1)Convection<br>40 (2)Forced air (0.5m [3] / min)<br>20<br>15<br>0<br>-20 -10 0 10 20 30 40 45 50 60 70<br>Ambient temperature [ C ]<br>Load factor [%]<br>**----- End of picture text -----**<br>
- ¿ PDA100F
Ambient temperature derating curve (Reference value)
**==> picture [221 x 109] intentionally omitted <==**
**----- Start of picture text -----**<br>
(2)A-C mounting<br>(1)B,C mounting (1)A mounting<br>100<br>80<br>60<br>(1)Convection<br>40 (2)Forced air (0.5m [3] / min)<br>20<br>15<br>0<br>-20 -10 0 10 20 30 40 50 60 70<br>Ambient temperature [ C ]<br>Load factor [%]<br>**----- End of picture text -----**<br>
## ¿ PDA150F-3R3, -5
- Ambient temperature derating curve (Reference value)
**==> picture [221 x 109] intentionally omitted <==**
**----- Start of picture text -----**<br>
(2)A-C mounting<br>(1)B,C mounting (1)A mounting<br>100<br>80<br>60<br>(1)Convection<br>40 (2)Forced air (0.5m [3] / min)<br>20<br>15<br>0<br>-20 -10 0 10 20 30 35 40 50 60 70<br>Ambient temperature [ C ]<br>Load factor [%]<br>**----- End of picture text -----**<br>
- ¿ PDA150F-12, -15, -24, -36, -48 Ambient temperature derating curve (Reference value)
**==> picture [221 x 109] intentionally omitted <==**
**----- Start of picture text -----**<br>
(2)A-C mounting<br>(1)B,C mounting (1)A mounting<br>100<br>80<br>60<br>(1)Convection<br>40 (2)Forced air (0.5m [3] / min)<br>20<br>15<br>0<br>-20 -10 0 10 20 30 40 50 60 70<br>Ambient temperature [ C ]<br>Load factor [%]<br>**----- End of picture text -----**<br>
- ¿ PDA50F-12-N, -15-N, -24-N, -36-N, -48-N Ambient temperature derating curve (Reference value)
**==> picture [224 x 108] intentionally omitted <==**
**----- Start of picture text -----**<br>
(1)C mounting (1)A mounting (2)A-C mounting<br>(1)B mounting<br>100<br>80<br>60<br>50 (1)Convection<br>40 (2)Forced air (0.5m [3] / min)<br>30<br>20<br>15<br>0<br>-20 -10 0 10 20 30 40 45 50 60 70<br>Ambient temperature [ C ]<br>Load factor [%]<br>**----- End of picture text -----**<br>
- ¿ PDA100F-□-N
Ambient temperature derating curve (Reference value)
**==> picture [221 x 109] intentionally omitted <==**
**----- Start of picture text -----**<br>
(2)A-C mounting<br>(1)B,C mounting (1)A mounting<br>100<br>80<br>60<br>(1)Convection<br>40 (2)Forced air (0.5m [3] / min)<br>20<br>15<br>0<br>-20 -10 0 10 20 30 40 50 60 70<br>Ambient temperature [ C ]<br>Load factor [%]<br>**----- End of picture text -----**<br>
## ¿ PDA150F-3R3-N, -5-N
- Ambient temperature derating curve (Reference value)
**==> picture [222 x 109] intentionally omitted <==**
**----- Start of picture text -----**<br>
(2)A-C mounting<br>(1)B,C mounting (1)A mounting<br>100<br>80<br>60<br>(1)Convection<br>40 (2)Forced air (0.5m [3] / min)<br>20<br>15<br>0<br>-20 -10 0 10 20 30 35 40 50 60 70<br>Ambient temperature [ C ]<br>Load factor [%]<br>**----- End of picture text -----**<br>
- ¿ PDA150F-12-N, -15-N, -24-N, -36-N, -48-N Ambient temperature derating curve (Reference value)
**==> picture [222 x 109] intentionally omitted <==**
**----- Start of picture text -----**<br>
(2)A-C mounting<br>(1)B,C mounting (1)A mounting<br>100<br>80<br>60<br>(1)Convection<br>40 (2)Forced air (0.5m [3] / min)<br>20<br>15<br>0<br>-20 -10 0 10 20 30 40 50 60 70<br>Ambient temperature [ C ]<br>Load factor [%]<br>**----- End of picture text -----**<br>
**PDA-19**
January 29, 2026
## **PDA-series**
## **Derating**
- ¡ The operating ambient temperature is different by with / without chassis cover or mounting position.
- ¡ In the hatched area, the specification of Ripple, Ripple Noise is different from other area.
- ¡ The ambient temperature should be measured 5 to 10 cm away from the power supply so that it won’t be influenced by the heat from the power supply.
- ¡ Please make sure the maximum component temperature rise given in Instruction manual 4 is not exceeded.
- ¡ Please contact us for more information about operating ambient temperature.
- ¿ PDA300F, PDA600F Ambient temperature derating curve (Reference value)
**==> picture [208 x 91] intentionally omitted <==**
**----- Start of picture text -----**<br>
100<br>80<br>60<br>50<br>40<br>20<br>0<br>-20 -10 0 10 20 30 40 50 60 70<br>Ambient temperature [ C ]<br>Load factor [%]<br>**----- End of picture text -----**<br>
- ¡ In the hatched area, the specification of Ripple, Ripple Noise is different from other area.
- ¡ Derating curve depending on an ambient temperature (temperature of air sucked in for a cooling purpose) is shown above.
## **Instruction Manuals**
- Please see catalog and instructionmanual before you use.
## **Basic Characteristics Data**
**==> picture [506 x 156] intentionally omitted <==**
**----- Start of picture text -----**<br>
Switching Input Inrush PCB/Pattern oSeries/Parallelperation availability<br>Model Circuit method frequency current current<br>[kHz] *1 *2 *3 [[A]] protection Material Singlesided Double opSerieseration oParallelperation<br>PDA15F Flyback converter 20 to 125 0.35 Thermistor CEM-3 Yes - Yes No<br>PDA30F Flyback converter 30 to 130 0.62 Thermistor CEM-3 Yes - Yes No<br>PDA50F Flyback converter 25 to 130 1.05 Thermistor CEM-3 Yes - Yes No<br>PDA100F Active filter 20 to 250 1.3 Thermistor FR-4 - Yes Yes No<br>Flyback converter 45 to 110<br>PDA150F Active filter 20 to 250 1.8 Thermistor FR-4 - Yes Yes No<br>Flyback converter 45 to 110<br>Active filter 65<br>PDA300F 4.1 Thermistor FR-4 Yes Yes Yes<br>Forward converter 140<br>Active filter 65<br>PDA600F 7.9 SCR FR-4 Yes Yes Yes<br>Forward converter 220<br>**----- End of picture text -----**<br>
- *1 The value changes depending on input and load.
- *2 At light load, burst operation is performed to reduce input power. The switching frequency is changed by using condition. Please contact us for more details.
- *3 The value of input current is at ACIN 100V and rated load.
- *1,*2 are only for PDA15F-150F
**PDA-20**
January 29, 2026
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →