## **Photoelectrics Through-beam Type PD30CNT15....MU/DU**
- **Miniature sensor range**
- **Range: 15 m**
- **Sensitivity adjustment by Teach-In programming**
- **Modulated, Infraredred light 880 nm**
- **Supply voltage: 10 to 30 VDC**
- **Output: 100 mA, NPN or PNP preset**
- **Make and break switching function programmable**
- **LED indication for output, stability and power ON**
- **Protection: reverse polarity, short circuit and transients**
- **Cable and plug versions**
- **Excellent EMC performance**
- **Mute function (Sensor blanking) Emitter**
**• Dust alarm output - Receiver** ul CE @= **Orderin Ke g y PD30CNT15NPM5DU** ~~—o—ES———=—=—=—=—==~~ ty makes the sensors highly **Type** flexible. The output type is **Housing style** preset (NPN or PNP), and **Housing size** the output switching function **Housing material** is programmable (NO or NC), **Housing length** and one dust output NO or **Detection principle** NC. **Sensing distance** The mute function can be **Output type** used for testing the sensor **Output configuration** for: Malfunctioning, discon- **Connection type** nection, optical axis adjust- **Dust** ment, dusty and dirty lenses.
## **Product Descri tion p**
## ~~el~~
The PD30CNT15 sensor family comes in a compact 10 x 30 x 20 mm reinforced PMMA/ABS housing.
The sensors are useful in applications where high-accuracy detection as well as small size is required. Compact housing and high power LED for excellent performance-size ratio. The Teach-In function for adjustment of the sensitivi-
## **T e Selection yp**
|**Housing**<br>**Range Connection Ordering no.**|**Range Connection Ordering no.**|**Range Connection Ordering no.**|**Ordering no.**|**Ordering no.**|**Ordering no.**|
|---|---|---|---|---|---|
|**W x H x D**<br>**Sn**||**NPN**|**NPN**|**PNP**|**PNP**|
|||**Emitter**|**Make or break switching Emitter**|**Emitter**|**Make or break switching**|
|10 x 30 x 20 mm 15 m|Cable|**PD 30 CNT 15 NMU**|**PD 30 CNT 15 NPDU**|**PD 30 CNT 15 PMU**|**PD 30 CNT 15 PPDU**|
|10 x 30 x 20 mm 15 m|Plug|**PD 30 CNT 15 NM5MU**|**PD 30 CNT 15 NPM5DU**|**PD 30 CNT 15 PM5MU PD 30 CNT 15 PPM5DU**|**PD 30 CNT 15 PM5MU PD 30 CNT 15 PPM5DU**|
**Note:** Emitter, Receiver and Connector to be ordered separately.
## **S ecifications Emitter** EN 60947-5-2 **p**
|**Rated operational volt.**(UB)<br>**Ripple**(Urpp)<br>**Supply current**<br>**Light Source**<br>**Optical angle**<br>**Light type **|10 to 30 VDC<br>≤ 10%<br>≤ 25 mA<br>GaAIAs,LED,880 nm<br>± 2º at ½ range<br>Infrared,modulated|
|---|---|
|**Light spot**|110 mm @ 1.5 m|
|**Protection**|||Reversepolarity,transients|
|---|---|---|---|
|**Indication function**||||
|Power supplyON|ON||LED, green|
|**Mute function**||||
|Emitter off|0 to 3 sec|0 to 3 sec|0 to 2.5 VDC (NPN)|
||||5 to 30 VDC (PNP)|
|Emitter half power||> 3 sec|0 to 2.5 VDC (NPN)|
||||5 to 30 VDC (PNP)|
## **S ecifications Receiver** EN 60947-5-2 **p**
|**Rated operating distance**(Sn) 15 m, with PD30CNT15|) 15 m, with PD30CNT15|
|---|---|
||Emitter|
|**Blind zone**<br>**Sensitivity**<br>**Temperature drift**<br>**Hysteresis**(H)<br> (differential travel)<br>**Rated operational volt.**(UB)<br>**Ripple**(Urpp)<br>**Adjustable range**<br>resolution|None<br>Adjustable byTeach-In<br>≤ 0.3%/ºC<br>≤ 10%<br>10 to 30 VDC<br>≤ 10%<br>1.5 m to 15 m<br>3% on distance|
|**Output current**||
|---|---|
|Continuous (Ie)|≤ 100 mA|
|Short-time (I)|≤ 100 mA|
||(max. load capacity100 nF)|
|**Dust output current**||
|Continuous (Ie)|≤ 20 mA|
|Short-time (I)|≤ 20 mA|
||(max. load capacity100 nF)|
|**No load supply current**(Io)|≤ 30 mA|
|**Minimum operational current**(Im)|0.5 mA|
|**OFF-state current**(Ir)|≤ 100 µA|
**1**
Specifications are subject to change without notice (24.08.2016)
**PD30CNT15....MU/DU**
**==> picture [72 x 40] intentionally omitted <==**
## **Specifications Receiver (cont.)** EN 60947-5-2
|**Voltage drop **(Ud)<br>**Protection**<br>**Sensing angle**<br>**Ambient light**<br>**Operating frequency**<br>**Response time**<br>OFF-ON (tON)<br>ON-OFF(tOFF)<br>**Power ON delay **(tv)|≤ 2.5 VDC @ 100 mA<br>Short-circuit, reverse polarity<br>and transients<br>± 4º<br>10,000 lux<br>1000 Hz<br>≤ 0.5 ms<br>≤ 0.5 ms<br>≤ 300 ms||
|---|---|---|
|**Output function**<br>NPN and PNP<br>NO/NC switching function<br>Programming options<br>Output pin 4 black<br>Outputpin 2 white<br>**Dust alarm output**<br>Delayon operate|Preset<br>Set up by button<br>NO or NC<br>NO or NC(dust)<br>20 ms||
|**Indication**<br>Output ON|LED, yellow||
|Signal stability ON and power ON|LED, green||
## **General S ecifications** EN 60947-5-2 **p**
|**Environment**||||
|---|---|---|---|
|Installation category||III (IEC 60664/60664A;||
|||60947-1)||
|Pollution degree||3 (IEC 60664/60664A;||
|||60947-1)||
|Degree ofprotection||IP 67(IEC 60529;60947-1)||
|**Ambient temperature**||||
|Operating||-25°to +55°C (-13°to +131°F)||
|Storage||-40°to +70°C(-40°to +158°F)||
|**Vibration**||10 to 55 Hz, 0.5 mm/7.5 g||
|||(IEC 60068-2-6)||
|**Shock**||30 g / 11ms, 3 pos, 3 neg||
|||per axis||
|||(IEC 60068-2-6,60068-2-32)||
|**Rated insulation voltage**||500 VAC(rms)||
|**Housing material**||||
|Body||ABS||
|Front material||PMMA,red||
|**Connection**||||
|Cable|Emitter/receiver|PVC, black, 2 m, Ø = 3.3 mm||
|||4 x 0.14 mm2||
|Plug||M8,4-pin(CON,54-series)||
|**Weight**(each|sensor)|With cable: 40 g||
|||Withplug: 10g||
|**CE-marking**||Yes||
|**Approvals**||cULus (UL508)||
## **O eration Dia ram p g**
tv = Power ON delay
**==> picture [483 x 115] intentionally omitted <==**
**----- Start of picture text -----**<br>
ON<br>Power supply OFF<br>Present<br>Object Not Present<br>ON T < 3 sec. T > 5 sec.<br>Mute (Emitter) OFF<br>100%<br>Emitted power 50%0%<br>Dirty<br>Optics Clean<br>ON Tv<br>Make Output (N.O.) OFF<br>ON Tv<br>Break Output (N.C.) OFF<br>**----- End of picture text -----**<br>
## **Wiring Diagrams**
**==> picture [500 x 161] intentionally omitted <==**
**----- Start of picture text -----**<br>
Receiver<br>Emitter<br>NPN PNP NPN PNP<br>1 BN V 1 BN V<br>1 BN V 1 BN V<br>2 WH<br>4 BK Mute<br>2 WH* 2 WH* Mute 2 WH<br>4 BK 3 BU 3 BU<br>3 BU 3 BU V V<br>GND GND Mute input active when Mute input active when<br>*Dust Output *Dust Output connected to GND connected to V+<br>**----- End of picture text -----**<br>
**2**
Specifications are subject to change without notice (24.08.2016)
**PD30CNT15....MU/DU**
## **Detection Diagram**
## **Excess Gain**
**==> picture [72 x 72] intentionally omitted <==**
**==> picture [502 x 364] intentionally omitted <==**
**----- Start of picture text -----**<br>
Emitter<br>X Y<br>Receiver (feet)<br>16.5 33 49.5 66<br>400 16 1000<br>300 12<br>200 8<br>100<br>100 4<br>0 0<br>10<br>-100 -4<br>-200 -8<br>-300 -12 1<br>1.0 10.0 100.0<br>-400 -16 Distance (m)<br>0 5 10 15 20<br>Sensing range (m)<br>Si nal Stabilit Indication Accessories<br>g y<br>21.2<br>14<br>9° 1.2 32.4<br>Excess Gain 25.4<br>3.2 1.2<br>1.25 Operation level x 1.25<br>1.0 Operation level<br>0.75 Operation level x 0.75<br>13.5 16.2<br>5.7 6.0 6.0 5.2<br>Time<br>Green LED ON<br>Yellow LED ON<br>Dust alarm t t 4.4 4.4<br>Mounting bracket: APD30-MB1 Mounting bracket: APD30-MB2<br>(mm) (inch) Excess Gain<br>25.4 9°<br>39<br>3.2 26,3 29.3<br>10<br>7.3 10 8.2 4.4<br>16 3 14<br>**----- End of picture text -----**<br>
## **Dimensions**
**==> picture [500 x 232] intentionally omitted <==**
**----- Start of picture text -----**<br>
Cable version Plug version<br>Teach Button* Teach Button*<br>Output LED Power / Stability LED Output LED Power / Stability LED<br>Yellow* Green Yellow* Green<br>10.6 10.6<br>10.8 10.8<br>17 17<br>Receiver or emitter Two, 9.5 dia. Receiver or emitter Two, 9.5 dia.<br>Lenses Lenses<br>Optical axis Optical axis<br>Two M3 Two M3<br>10.25<br>* Not avaible on emitter version<br>10.6 6 10.6 6<br>20 20<br>1.1 1.1<br>5.5 5.5<br>30 25.4 22 30 25.4 22<br>5.5 5.5<br>15 15<br>**----- End of picture text -----**<br>
**3**
Specifications are subject to change without notice (24.08.2016)
**PD30CNT15....MU/DU**
## **Installation Hints**
**==> picture [72 x 72] intentionally omitted <==**
**==> picture [500 x 118] intentionally omitted <==**
**----- Start of picture text -----**<br>
To avoid interference from inductive voltage / Relief of the cable strain Protection of the sensing face Sensor mounted on a mobile carrier<br>current peaks, separate the proximity switch<br>cables from any other power cables. E.g.<br>Engine, contactor or solenoid cables<br>Incorrect<br>Incorrect<br>Incorrect Correct<br>Correct<br>> 100 mm<br>A proximity switch should not serve Any repetitive flexing of the<br>The cable should not be pulled as mechanical stop cable should be avoided<br>**----- End of picture text -----**<br>
## **Deliver Contents y**
- Photoelectric switch: PD 30 CNT 15 ...
- Installation instruction
## **Accessories**
- Mounting bracket APD30-2 to be purchased separately
- Connector type CONG 5A../CON. 54NF.. series.
- Mountingbracket APD30-1
- **Packaging:** Cardboard box
**4**
Specifications are subject to change without notice (24.08.2016)
**PD30CNT15....MU/DU**
## **Teach functions**
## **Normal operation, optimized switching point**
1. Line up the emitter and receiver. Yellow LED and Green LED are ON.
2. Press the button for 3 seconds until both LEDs flashes simultaneously.
- (The first switch point is stored)
3. Place the object between the emitter and receiver in the detection zone.
4. Press the button once and the sensor is ready to operate (Green LED ON, Yellow LED ON) (The second switch point is stored)
**==> picture [244 x 93] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 2 3 4<br>3 sec. Push once<br>**----- End of picture text -----**<br>
## **For maximum sensing distance**
## **(default setting)**
1. Line up the emitter and receiver, place the object between the emitter and receiver in the detection
- zone. Yellow LED is OFF and Green LED is ON.
2. Press the button for 3 seconds until both LEDs flashes simultaneously.
- (The first switch point is stored)
3. Press the button a second time and the sensor is ready to operate (Green LED ON, Yellow LED ON) (The second switch point is stored)
**==> picture [177 x 83] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 2 3<br>3 sec. Push once<br>**----- End of picture text -----**<br>
**==> picture [32 x 42] intentionally omitted <==**
## **For minimum sensing distance**
**(Transparent or semi-transparent objects)**
1. Line up the emitter and receiver. Yellow LED and Green LED are ON.
2. Press the button for 3 seconds until both LEDs flashes simultaneously.
**==> picture [72 x 72] intentionally omitted <==**
## **For dynamic set-up (running process)**
1. Line up the emitter and receiver. Green LED is ON, status on the yellow LED is not important.
2. Press the button for 3 second until both LEDs flashes simultaneously.
- (The first switch point is stored)
3. Press the button a second time and keep the button pressed for at least one process cycle, release the button and the sensor is ready to operate (The second switch point is stored)
**==> picture [165 x 81] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 2 3<br>3 sec. Push once<br>**----- End of picture text -----**<br>
**==> picture [38 x 54] intentionally omitted <==**
## **For make or break set-up**
1. Press the button for 10 seconds, until the green LEDs flashes.
2. While the green LED flashes, the output is inverted each time the button is pressed. Yellow LED indicates N.O. function selected.
If the button is not pressed within the next 10
- seconds, the current output is stored.
**==> picture [134 x 85] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 2<br>10 sec. Push once<br>**----- End of picture text -----**<br>
## **For dust output (N.O. or N.C.)**
1. Press the button for 15 seconds, until the yellow LEDs flashes.
2. While the yellow LED flashes, the dust output is inverted each time the button is pressed. Green LED indicates N.O. function selected.
- If the button is not pressed within the next 10
- seconds, the current output is stored.
- (The first switch point is stored)
3. Press the button a second time and the sensor is ready to operate (Green LED ON, Yellow LED ON) (The second switch point is stored)
**==> picture [165 x 81] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 2 3<br>3 sec. Push once<br>**----- End of picture text -----**<br>
**==> picture [38 x 44] intentionally omitted <==**
**==> picture [135 x 81] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 2<br>15 sec. Push once<br>**----- End of picture text -----**<br>
**5**
Specifications are subject to change without notice (24.08.2016)
Updated at April 27, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →