Image not available
Illustrative purposes only
PCD200-24-B-2R-100.
PANEL METER, PROCESS, 6-DIGIT, 24VDC
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: AMPHENOL WILCOXON
- Product type: Digital Panel Meters
- No. of Digits / Alpha:6; Meter Function:Process; Meter Range:0mA to 20mA / 4mA to 20mA / 0V to 5V / 1V to 5V / ± 10V; Digit Height:0.6"; Panel Cutout Height:1.772 88AH8499
- Meter Range: 0mA to 20mA / 4mA to 20mA / 0V to 5V / 1V to 5V / ± 10V
- Digit Height: 0.6"
- Product Range: PCD200 Series
- Meter Function: Process
- Panel Cutout Width: 3.622"
- Supply Voltage Max: 24VDC
- Supply Voltage Min: 12VDC
- Panel Cutout Height: 1.772"
- No. of Digits / Alpha: 6
- Operating Temperature Max: 65°C
- Operating Temperature Min: -40°C
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 830.47 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **Dual-input process meters** ## PCD200 series The PCD200 series are 1/8 DIN digital panel meters that accepts two inputs of either a process current (4-20 mA) or process voltage (0-5V, 1-5V, ±10V) signal. It displays these signals on a dual line, 6-digit display that is available with an optional Sunbright® sunlight readable LEDs. The meter can be customized such that these two inputs are displayed in a variety of ways, including both at the same time with tags or the result of math functions performed on one or both of the inputs. The PCD200 features CE marking, a NEMA 4X front, and AC or DC power options, and can be equipped with up to four internal relays, a 4-20 mA analog output, and Modbus® serial communications. PCD200 meters can be programmed via the front panel pushbuttons or included PC-based software. **==> picture [371 x 124] intentionally omitted <==** **----- Start of picture text -----**<br> UV resistant SunBright<br>Rugged NEMA 4X / IP65<br>sunlight readable models<br>front panel<br>User configurable math<br>Large 0.6” digits function result<br>_<br>Dual-line<br>6 character — FA<br>Programmable<br>display<br>function keys<br>User configurable F3 Alarm status<br>custom tag Ww WILCOXON SENSING TECHNOLOGIES indicators<br>**----- End of picture text -----**<br> ## **Key features** - Dual input process meter with math functions - 0-20 mA, 4-20 mA, 0-5 V, 1-5 V, and ± 10 V inputs - SunBright display models for outdoor applications - NEMA 4X, IP65 front panel ## **Ordering information** |**Ordering informationg information information**|**Ordering informationg information information**|**Ordering informationg information information**|**Ordering informationg information information**| |---|---|---|---| ||**85-265 VAC models**|**12-24 VDC models**|**Options installed**| |**Standard**|PCD200-265-B-N-200|PCD200-24-B-N-100|none| ||PCD200-265-B-2R-200|PCD200-24-B-2R-100|2 relays| ||PCD200-265-B-420-240|PCD200-24-B-420-140|4-20 mA output| ||PCD200-265-B-4R-200|PCD200-24-B-4R-100|4 relays| ||PCD200-265-B-2R420-240|PCD200-24-B-2R420-140|2 relays + 4-20 mA output| ||PCD200-265-B-4R420-240|PCD200-24-B-4R420-140|4 relays + 4-20 mA output| |**SunBright display**|PCD200-265-SB-N|PCD200-24-SB-N-100|none| ||PCD200-265-SB-2R|PCD200-24-SB-2R-100|2 relays| ||PCD200-265-SB-420|PCD200-24-SB-420-140|4-20 mA output| ||PCD200-265-SB-4R-200|PCD200-24-SB-4R-100|4 relays| ||PCD200-265-SB-2R420-240|PCD200-24-SB-2R420-140|2 relays + 4-20 mA output| ||PCD200-265-SB-4R420-240|PCD200-24-SB-4R420-140|4 relays + 4-20 mA output| - Input power options include 85-265 VAC or 12-24 VDC - 2 or 4 relays + isolated 4-20 mA output options - Includes PC-based programming and monitoring software ## **Certifications** Accessories available. NOTE: A 24 V transmitter power supply is standard and may be used to power the inputs. Note: Due to continuous process improvement, specifications are subject to change without notice. This document is cleared for public release. ## **Wilcoxon Sensing Technologies** Tel: +1 (301) 330-8811 Fax: +1 (301) 330-8873 info@wilcoxon.com 8435 Progress Drive Frederick, MD 21701 USA buy.wilcoxon.com www.wilcoxon.com An Amphenol Company **1** 99389 Rev.A 08/20 ## **Dual-input process meters** ## PCD200 series ## **DISPLAY FEATURES** ## **Easy to use, customizable displays** The dual-line display makes the PCD200 easy to set up and program, and all configuration can be done via the front panel. PCD200 series meters have an upper and lower display, each a full 6 digits (-999999 to 999999). The displays can be set up to read input channels (A or B), math function channel C, toggle between A & B, B & C, A & C, A & B & C, toggle between channels A, B, or C & units, the max/min of any of the channels (including math channel C), set points, gross, or net & gross values of channel A or B, or the Modbus input. This allows the meter to show the most relevant variables for the application. Math function & tag Input channels A & B ## **Alternation display** Certain options alternate the display information. A single display can show input variable information as well as that channel’s unit or tag. Input and math function channels, gross and net values, and select inputs and the math results may also alternate on a single display. Lower display alternating input channels A & B ## **Standard LED and SunBright LED display models** PCD200 meters feature ultra-bright LED displays. Both standard and SunBright models perform well in both indoor and outdoor settings where visibility may be impaired by smoke, fog, dust, or distance. The UV-resistant SunBright display option is even readable in sunlight and ideal for use in outdoor applications. ## **DIMENSIONS** **==> picture [148 x 158] intentionally omitted <==** **----- Start of picture text -----**<br> 1.76”<br>[44.5 mm]<br>2.45”<br>[62.2 mm]<br>0.59” 4.77” [121.2 mm]<br>[15.0 mm]<br>5.05” [128.3 mm]<br>6” [152 mm] clearance<br>Side view<br>**----- End of picture text -----**<br> **==> picture [186 x 172] intentionally omitted <==** **----- Start of picture text -----**<br> Optional connectors _ fai<br>installed<br>4.17”<br>[106 mm]<br>3.61”<br>[91.5 mm]<br>4.68” [118.9 mm] oS<br>Top view<br>**----- End of picture text -----**<br> Note: Due to continuous process improvement, specifications are subject to change without notice. This document is cleared for public release. **Wilcoxon Sensing Technologies** Tel: +1 (301) 330-8811 Fax: +1 (301) 330-8873 info@wilcoxon.com 8435 Progress Drive Frederick, MD 21701 USA buy.wilcoxon.com www.wilcoxon.com An Amphenol Company **2** 99389 Rev.A 08/20 ## **Dual-input process meters** PCD200 series ## **SPECIFICATIONS** ## **GENERAL** |**GENERAL**<br>**SPECIFICATIONS**||| |---|---|---| |**Display**<br>**Frontpanel**|Upper display: 0.60:(15mm)high, lower display: 0.46”(12 mm)high, 6 digits each, red LEDs<br>NEMA 4X, IP65<br>~~=~~|| |**Programming methods**|Four front panel buttons, digit inputs, PC with MeterView software, Modbus registers, or cloning<br>usingCopyfunction|| |**Power options**|85-265 VAC, 50/60 Hz; 90-265 VDC, 20 W max; optional model with 12-24 VDC ±10%, 15 W max|| |**Required fuse**|UL recognized, 5 A max, slow-blow; upto 6 meters mayshare one 5 A fuse|share one 5 A fuse| |**Isolated transmitter power**<br>**supply**|Terminals P+ & P-: 24 VDC ± 10%. Internally selectable jumper for 24, 10, or 5 VDC supply. 85-265<br>VAC models rated @ 200 mA max, 12-24 VDC powered models rated @ 100 mA max, @ 50 mA<br>max for 5 or 10 VDC supply.|Terminals P+ & P-: 24 VDC ± 10%. Internally selectable jumper for 24, 10, or 5 VDC supply. 85-265<br>VAC models rated @ 200 mA max, 12-24 VDC powered models rated @ 100 mA max, @ 50 mA| |**Isolation**|4 kV input/output-to-power line; 500 V input-to-output or out|ut or output or output-to-P+ supply| |**Temperature range:**||| |**Operating**|-40° to 65°C|| |**Storage**|-40° to 85°C|| |**Relative humidity**|0 to 90% non-condensing|| |**Connections**|Removable screw terminal blocks accept 12 to 22 AWG, RJ45 for external relays, digital I/O, and<br>serial communmication adapters|| |**Enclosure**|1/8 DIN, high impactplastic, UL 94V-0, color: black|| |**Mounting**|1/8 DINpanel cutout required: 3.622” x 1.772”|| |**Tightening torque**|Screw terminal connectors: 5 lb-in(0.56 Nm)|| |**Weight**|269grams(9.5 oz)|| |**USB connection**|Compatibility: USB 2.0 Standard; compliant connector type: Micro-B receptacle; cable: USB A male<br>to Micro-B cable;power: USBport|| |||| |**DUAL PROCESS INPUT**||| |**Inputs**|Two non-isolated inputs, separately field selectable: 0-20 mA, 4-20 mA, 10 V (0-5, 1-5, 0-10 V),<br>Modbus PV(Slave)|| |**Accuracy**<br>~~|~~|±0.03% of calibrated span ±1 count, square root & programmable exponent accuracy range: 10-<br>100% of calibrated span|| |**Temperature drift:**||| |**0 to 65°C ambient**|0.005% of calibrated span/°C max|| |**-40 to 0°C ambient**|0.01% of calibrated span/°C max|| |**Signal input conditioning**|linear, square root,programmable exponent, or round horizontal tank volume calculation|| |**Calibration range**|4-20 mA: minimum span input 1 & input 2: 0.15 mA<br>±10 V: minimum span input 1 & 2: 0.10 V|| |**Input impedance:**||| |**Voltage ranges**|>500 kΩ|| |**Current ranges**|50-100 Ω, varies with resettable fuse impedance|| |**Input overload**|current inputprotected byresettable fuse, 30 VDC max1|| **Notes:**[1] Fuse resets automatically after fault is removed. Note: Due to continuous process improvement, specifications are subject to change without notice. This document is cleared for public release. **Wilcoxon Sensing Technologies** Tel: +1 (301) 330-8811 Fax: +1 (301) 330-8873 info@wilcoxon.com 8435 Progress Drive Frederick, MD 21701 USA buy.wilcoxon.com www.wilcoxon.com An Amphenol Company **3** 99389 Rev.A 08/20 ## **Dual-input process meters** ## PCD200 series ## **SPECIFICATIONS** ## **RELAYS** |**RELAYS**<br>**SPECIFICATIONS**|| |---|---| |**Rating**|2 or 4 SPDT (Form C) internal and/or 4 SPST (Form A) external; rated 3 A @ 30 VDC and 125/250<br>VAC resistive load; 1/14 HT(approx. 50 W) @125/250 VAC for inductive loads| ||automatic (non-latching);| ||latching (requires manual acknowledge);| |**Relay operation**|sampling (based on time);| ||pump alteration control (2 to 8 relays);| ||Off(disable unused relays and enable interlock feature, manual on/off control mode)| |**Time delay**|0 to 999.9 seconds, on and off relaytime delays;programmable & independent for each relay| ||| |**SERIAL COMMUNICATIONS**|| |**Protocol**|Modbus RTU| |**Meter address/Slave ID**|1 to 247| |**Baud rate**|300 to 19,200 bps| |**Transmit time delay**|Programmable between 0 and 199 ms| |**Data**|8 bit(1 start bit, 1 or 2 stopbits)| |**Parity**|Even, odd or none with 1 or 2 stopbits| |**Byte-to-byte timeout**|0.01 - 2.54 seconds| |**Turn around delay**|< 2 ms(fixed)| ||| |**ISOLATED 4-20 mA TRANSMITTER OUTPUT**|| |**Output source**|Process channel A, B, or C, max or min for channel A, B, or highest and lowest max or min of A<br>and B, setpoints 1-8, Modbus input, or manual control mode| |**Scaling range**|1.000 to 23.000 mA for anydisplayrange| |**Accuracy**|±0.1% of span ±0.004 mA| |**Temperature drift2:**|| |**0 to 65°C ambient**|0.4 µA/°C max| |**-40 to 0°C ambient**|0.8µA/°C max| |**Isolated transmitter power**|Terminals I+ & R: 24 VDC ±10%, isolated from the input at >500 V; may be used to power the 4-20| |**supply**|mA output or other devices; all models rated@40 mA max| |**External loop power supply**|35 VDC maximum| |**Output loop resistance**|see Table 1| **Notes:**[2] Analog output drift is separate from input drift. **Table 1: Output loop resistance** |**Power supply**|**Minimum**|**Maximum**| |---|---|---| |24 VDC|10 Ω|700 Ω| |35 VDC (external)|100 Ω|1200 Ω| Note: Due to continuous process improvement, specifications are subject to change without notice. This document is cleared for public release. **Wilcoxon Sensing Technologies** Tel: +1 (301) 330-8811 Fax: +1 (301) 330-8873 info@wilcoxon.com 8435 Progress Drive Frederick, MD 21701 USA buy.wilcoxon.com www.wilcoxon.com An Amphenol Company **4** 99389 Rev.A 08/20
Updated at June 9, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →