Image not available
Illustrative purposes only
PCD100-265-B-N-200.
PANEL METER, TEMP/PROCESS, 4-DIGIT, 265V
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: AMPHENOL WILCOXON
- Product type: Digital Panel Meters
- No. of Digits / Alpha:4; Meter Function:Temperature / Process; Meter Range:0mA to 20mA / 4mA to 20mA / 1V to 5V / -10V to +10V; Digit Height:1.2"; Panel Cutou 88AH8491
- Meter Range: 0mA to 20mA / 4mA to 20mA / 1V to 5V / -10V to +10V
- Digit Height: 1.2"
- Product Range: PCD100 Series
- Meter Function: Temperature / Process
- Panel Cutout Width: -
- Supply Voltage Max: 265VAC
- Supply Voltage Min: 85VAC
- Panel Cutout Height: -
- No. of Digits / Alpha: 4
- Operating Temperature Max: 65°C
- Operating Temperature Min: -40°C
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 527.68 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **Process and temperature meters** ## PCD100 series The PCD100 digital panel meters are one of the most versatile on the market, and are used in a wide variety of process and temperature applications. The PCD100 can be field programmed to accept common process voltage (1-5V, ± 10V) and current (0-20 mA, 4-20 mA) inputs, 100 Ω RTDs, and the four most common thermocouples. One of the PCD100’s most useful features is its ability to provide 24 VDC to power the transmitter’s 4-20 mA signal. There are two power options: 85265 VAC or 12-36 VDC. The meter can be programmed via front panel or remotely. **==> picture [114 x 19] intentionally omitted <==** **----- Start of picture text -----**<br> Front Panel NEMA 4X, IP65 Rated<br>PCD100 series<br>**----- End of picture text -----**<br> The display is four full digits, meaning it can display numbers up to 9999, an advantage over most digital panel meters. The PCD100 can display type K thermocouples to 2300°F and 4-20 mA signals up to 9,999. ## **Key features** The meter is supplied with two alarm points that include front panel red LEDs to indicate alarm conditions, making it particularly useful for alarm applications that require visual-only indication. ## **Ordering information** |**Ordering informationg information information**|**Ordering informationg information information**|**Ordering informationg information information**| |---|---|---| |**85-265 VAC**|**12-36 VDC**|**Options installed**| |PCD100-265-B-N-0|PCD100-24-B-N-0|none| |PCD100-265-B-N-200||24 VDC transmitter supply| |PCD100-265-B-2R-0|PCD100-24-B-2R-0|2 relays| |PCD100-265-B-2R-200||2 relays + 24 VDC transmitter<br>supply| |PCD100-265-B-420-0|PCD100-24-B-420-0|4-20 mA output| |PCD100-265-B-420-200||4-20 mA output + 24 VDC<br>transmitter supply| |PCD100-265-B-420-240||4-20 mA output + dual 24 VDC<br>transmitter supplies| ||PCD100-24-B-2R420-0|2 relays + 4-20 mA output| |PCD100-265-B-2R420-200||2 relays + 4-20 mA output + 24<br>VDC transmitter supply| - NEMA 4X, IP65 front panel - 4-20 mA, ±10V, TC & RTD field-selectable inputs - Options for 2 relays, isolated 4-20 mA output, and 24 VDC transmitter power supplies - Includes PC-based programming and monitoring software - External contacts for remote button operation ## **Certifications** Note: Due to continuous process improvement, specifications are subject to change without notice. This document is cleared for public release. **Wilcoxon Sensing Technologies** Tel: +1 (301) 330-8811 Fax: +1 (301) 330-8873 info@wilcoxon.com 8435 Progress Drive Frederick, MD 21701 USA buy.wilcoxon.com www.wilcoxon.com An Amphenol Company **1** 99388 Rev.A 08/20 ## **Process and temperature meters** PCD100 series ## **DIMENSIONS** **==> picture [487 x 178] intentionally omitted <==** **----- Start of picture text -----**<br> 1.76” [44.7 mm] ,eeee 5<br>2.50”<br>[63.5 mm]<br>2.45”<br>[62.2 mm]<br>3.61”<br>[91.7 mm]<br>ee| ee<br>0.59” 3.20” [81.3 mm]<br>[15.0 mm]<br>3.60” [91.4 mm] 4.68” [118.9 mm]<br>|___ ___,<br>Side view Top view<br>**----- End of picture text -----**<br> ## **SPECIFICATIONS** ## **GENERAL** |**SPECIFICATIONS**<br>**GENERAL**|| |---|---| |**Display**|1.2”(30.5 mm)height, 4 digits, red LED| |**Display intensity**|Eight levels, user-selectable| |**Frontpanel**|NEMA 4X, IP65(panelgasketprovided)| |**Programming methods**|Four frontpanel buttons, cloningwith Copyfeature, PC with MeterView software, Modbus registers| ||85-265 VAC, 50/60 Hz;| |**Power options**|90-265 VDC, 20 W max or 12-36 VDC;| ||12-24 VAC, 6 W max| |**Required fuse**|UL recognized, 5 A max, slow-blow; upto 6 meters mayshare one fuse| ||4 kV input/output-to-power line;| |**Isolation**|500 V input-to-output or output to 24 VDC supplies;| ||-2R420 models only: 100 V output-to-24 VDC supply| |**Temperature range**|Operating: -40° to 65°C<br>Storage: -40° to 85°C| |**Relative humidity**|0 to 90% non-condensing| |**Connections**|Power & signal: removable screw terminal blocks accept 12 to 22 AWG<br>Serial: RJ11 header, standard on all meters| |**Enclosure**|1/8 DIN, high impactplastic, 94V-0, color:gray| |**Weight**|269grams(9.5 oz) (includingoptions)| Note: Due to continuous process improvement, specifications are subject to change without notice. This document is cleared for public release. **Wilcoxon Sensing Technologies** Tel: +1 (301) 330-8811 Fax: +1 (301) 330-8873 info@wilcoxon.com 8435 Progress Drive Frederick, MD 21701 USA buy.wilcoxon.com www.wilcoxon.com An Amphenol Company **2** 99388 Rev.A 08/20 ## **Process and temperature meters** ## PCD100 series ## **SPECIFICATIONS** ## **PROCESS INPUTS** |**PROCESS INPUTS**<br>**SPECIFICATIONS**|| |---|---| |**Inputs**|0-20 mA, 4-20 mA, 1-5 V, ± 10V| |**Transmitter supply**|Isolated, one or two transmitter supplies| |**P1**|24 VDC ± 10% @ 200 mA max (-200 models)| |**P1 & P2**|24 VDC ± 10%@200 mA and 40 mA max(-240 models)| |**Accuracy**|±0.05% FS ±1 count; square root: ±0.1% FS ± 2 counts| |**Function**|linear or square root| |**Calibration range**|userprogrammable over entire range of meter| |**Input impedance**|Voltage range: >1 MΩ<br>Current range: 50-100 Ω, varies with resettable fuse impedance| |**Input overload**|protected byautomaticallyresettable fuse| |**Temperature drift**|see table 1| |**TEMPERATURE INPUTS**|| |**Inputs**|Factory-calibrated, field selectable, type J, K, T, or E(see table 2)| |**Resolution**|1°; type T TC & RTD: 1° or 0.1°| |**Coldjunction reference**|automatic| |**Temperature drift**|± 2°C maximum| |**Offset adjustment**|programmable to ±19.9°(allows user to applyan offset value to the temperature beingdisplayed)| |**Input impedance**|>100 kΩ| |**RELAYS**|| |**Rating**|2 Form C (SPDT); rated 3 A @ 30 VDC or 3 A @ 250 VAC resistive load; 1/14 HP (=50 watts) @<br>125/250 VAC for inductive loads| **Relay operation Time delay** 0 to 199 seconds, on and off delays; programmable |**Table 1: Temperature drift**|**Table 1: Temperature drift**|**Table 1: Temperature drift**| |---|---|---| |**Input**|**0 to 65°C ambient**|**-40 to 0°C ambient**| |Current|±0.20% FS (50 PPM/°C)|±0.80% FS| |Voltage|±0.02% FS (1.7 PPM/°C)|±0.06% FS| **Table 2: Temperature input types** |**Table 2: Temperature input typesperature input typeserature input typesput typesut typesypeses**|**Table 2: Temperature input typesperature input typeserature input typesput typesut typesypeses**|**Table 2: Temperature input typesperature input typeserature input typesput typesut typesypeses**|**Table 2: Temperature input typesperature input typeserature input typesput typesut typesypeses**|**Table 2: Temperature input typesperature input typeserature input typesput typesut typesypeses**| |---|---|---|---|---| |**Type**|**Range**|**Acc. (0 to 65°C)**|**Acc. (-40 to 0°C)**|**Resolution**| |J|-58° to 1382°F<br>-50°C to 750°C|± 2°F<br>± 1°C|± 5°F<br>± 3°C|1°| |K|-58° to 2300°F<br>-50°C to 1260°C|± 2°F<br>± 1°C|± 4°F<br>± 2°C|1°| |T|-292° to 700°F<br>-180°C to 371°C|± 2°F<br>± 1°C|± 13°F<br>± 7°C|1° or 0.1°| |E|-58° to 1700°F<br>-50°C to 927°C|± 2°F<br>± 1°C|± 11°F<br>± 6°C|1°| |RTD|-328° to 1382°F<br>-200°C to 750°C|± 1°F<br>± 1°C|± 5°F<br>± 3°C|1° or 0.1°| Note: Due to continuous process improvement, specifications are subject to change without notice. This document is cleared for public release. **Wilcoxon Sensing Technologies** Tel: +1 (301) 330-8811 buy.wilcoxon.com Fax: +1 (301) 330-8873 www.wilcoxon.com info@wilcoxon.com 8435 Progress Drive Frederick, MD 21701 USA An Amphenol Company **3** 99388 Rev.A 08/20 ## **Process and temperature meters** ## PCD100 series ## **SPECIFICATIONS** ## **SERIAL COMMUNICATIONS** |**Protocol**|Modbus RTU| |---|---| |**Meter address**|PDC protocol: 0 to 99<br>Modbusprotocol: 1 to 247| |**Baud rate**|300 to 19,200 bps| |**Transmit time delay**|Programmable, 0 to 199 ms| |**Data**|8 bit(1 start bit, 1 stopbit)| |**Parity**|None(1 or 2 stopbits), even, or odd| |**Turn around delay**|< 2 ms(fixed)| |**ISOLATED 4-20 mA TRANSMITTER OUTPUT**|| |**Scaling range**|1.00 to 23.00 mA; reverse scalingallowed| |**Accuracy**|±0.1% FS ±0.004 mA| |**Temperature drift1**|50 PPM/°C| ||500 V input-to-output or output-to-24 VDC supplies;| |**Isolation**|4 kV output-to-power line;| ||100 V output-to-24 VDC supply (model PCD100-265-B-2R420-200 only)| |**Externalpower**|35 VDC maximum| |**Output loop resistance**|see table 3| |**EXTERNAL BUTTON CONTACTS**|| |**Number**|Four| |**Function**|Remote operation of front-panel buttons| |**Open state**|+5 VDC open contact on button input terminals| |**Closed state**|Closed contact button input terminal to common/ground, active low 0 to 0.4 VDC| **Notes:**[1] Analog output drift is separate from input drift. **Table 3: Output loop resistance** |**Power supply**|**Minimum**|**Maximum**| |---|---|---| |24 VDC|10 Ω|700 Ω| |35 VDC (external)|100Ω|1200 Ω| Note: Due to continuous process improvement, specifications are subject to change without notice. This document is cleared for public release. **Wilcoxon Sensing Technologies** Tel: +1 (301) 330-8811 Fax: +1 (301) 330-8873 info@wilcoxon.com 8435 Progress Drive Frederick, MD 21701 USA buy.wilcoxon.com www.wilcoxon.com An Amphenol Company **4** 99388 Rev.A 08/20
Updated at June 9, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →