PBR650PS12C
AC/DC Enclosed Power Supply (PSU), ITE & Medical, 1 Outputs, 650 W, 12 VDC, 50 A
- Manufacturer: XP POWER
- Product type: AC / DC Enclosed Power Supplies
- No. of Outputs:1Outputs; Output Power Max:600W; Output Voltage - Output 1:12V; Output Current - Output 1:50A; Output Voltage - Output 2:-; Output Current - Output 2:-; Output Voltage - Outp
- SVHC: No SVHC (15-Jan-2018)
- Product Range: PBR650 Series
- No. of Outputs: 1Outputs
- Output Power Max: 650W
- Input Voltage VAC: 80V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 50A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 12VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE & Medical
| Delivery and price | |
|---|---|
| Units per pack | 5 |
| Price | 248.58 € |
| Current stock | 10+ |
| Lead time | 30 days |
XP Power ## 650 Watts - Medical (BF) Safety Approvals - 4” x 8” Package - 5V Standby Supply - AC OK, Inhibit & Remote Sense - Class B Conducted & Radiated Emissions - 3 Year Warranty The PBR650 series of AC-DC switching power supplies, in a package of just 4 x 8 x 2.58 inches, deliver 600-650 watts of continuous power. They are designed for medical applications including those needing BF rated insulation with an operation altitude of up to 5000m. Dimensions: PBR650: 8.00 x 4.00 x 2.58” (203.2 x 101.6 x 65.5 mm) Models & Ratings |Output Voltage V1<br>Output Current V1(2)<br>Nominal<br>Peak(3)<br>as|Output Voltage V1<br>Output Current V1(2)<br>Nominal<br>Peak(3)<br>as|Output Voltage V1<br>Output Current V1(2)<br>Nominal<br>Peak(3)<br>as|Standby Supply V2<br>Ripple & Noise(1)<br>||Standby Supply V2<br>Ripple & Noise(1)<br>||Model Number(4)| |---|---|---|---|---|---| |12 V<br>50.00 A<br>55.00 A<br>15 V<br>40.00 A<br>44.00 A<br>18 V<br>36.12 A<br>40.00 A<br>24 V<br>27.09 A<br>30.00 A<br>28 V<br>23.22 A<br>25.50 A<br>36 V<br>18.06 A<br>20.00 A<br>48 V<br>13.55 A<br>15.00 A<br>57 V<br>11.41 A<br>12.50 A<br>~~**ee**~~<br>~~ee~~<br>~~ee~~<br>~~Po~~<br>~~|~~<br>~~|~~<br>~~Po~~<br>~~Pp~~<br>~~Pn~~<br>~~Pp~~<br>~~Po~~<br>~~po~~<br>~~PFPo~~<br>~~po~~<br>~~Pp~~<br>fF|||5.0 V / 0.2 A<br>120 mV<br>PBR650PS12C<br>150 mV<br>PBR650PS15C<br>180 mV<br>PBR650PS18C<br>240 mV<br>PBR650PS24C<br>280 mV<br>PBR650PS28C<br>360 mV<br>PBR650PS36C<br>480 mV<br>PBR650PS48C<br>570 mV<br>PBR650PS57C<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~_~~<br>~~**Po**~~<br>~~Po~~<br>~~Po~~<br>Pp<br>~~Po~~<br>~~Po~~<br>~~Po~~<br>~~Po~~<br>~~Po~~||| |~~**Notes**~~|||||| |~~**Notes**~~|||||| |_1. Ripple and noise is the maximum peak-to-peak voltage value measured at the output with 20 MHz bandwidth, at rated line voltage and output load, and with a 10_||_1. Ripple and noise is the maximum peak-to-peak voltage value measured at the output with 20 MHz bandwidth, at rated line voltage and output load, and with a 10μF _|||| |_tantalum capacitor in parallel with a 0.1μF ceramic capacitor._||_F ceramic capacitor._|||| |_2. All models may be operated at no-load without damage. At no load, output voltage fluctuates beyond 5% due to burst-mode operation of the control IC for energy_|||||| |_saving._|||||| |_3. Peak current available for 15s max, 10% duty cycle, average power not to exceed nominal power rating._|||||| |_4. For single fuse option add suffix -SP, e.g. PBR650PS12C-SP_|||||| |**Temperature Derating Curve**|||||| |100%|||||| |50%<br>Output Power|||||| |0%|||||| |-10|||50<br>70||| |||Ambient Temperature (ºC)|Ambient Temperature (ºC)||| ## ~~**Notes**~~ _1. Ripple and noise is the maximum peak-to-peak voltage value measured at the output with 20 MHz bandwidth, at rated line voltage and output load, and with a 10 μ F tantalum capacitor in parallel with a 0.1 μ F ceramic capacitor._ _2. All models may be operated at no-load without damage. At no load, output voltage fluctuates beyond 5% due to burst-mode operation of the control IC for energy saving._ _3. Peak current available for 15s max, 10% duty cycle, average power not to exceed nominal power rating._ _4. For single fuse option add suffix -SP, e.g. PBR650PS12C-SP_ ## **Temperature Derating Curve** **www.xppower.com** 1 **PBR650 Series AC-DC Power Supplies** XP Power Input Characteristic Minimum Typical Maximum Units Notes & Conditions Input Voltage 80 264 VAC Derate to 90% at 85 VAC & 80%at 80 VAC Input Frequency 47 63 Hz Input Current - Full Load 8.4/4.2 A (rms) 115/230 VAC, 60/50 Hz Earth Leakage Current 225 275 μ A 264 VAC, 63 Hz Output Characteristic Minimum Typical Maximum Units Notes & Conditions Output Voltage 12 57 VDC See Models and Ratings table Tolerance ±2 % Line and Load Regulation, 0.1% minimum load required to meet specification Transient Response 4 % Recovery within 1% in less than 500 μ s for a 25% step load change Ripple & Noise 1 % pk-pk 20 MHz bandwidth, see model table notes Overvoltage Protection 115 140 % Latching Overcurrent Protection 115 140 % Trip & restart characteristic Thermal Shutdown Protected for overtemperature conditions, latching Temperature Coefficient ±0.04 %/°C 5 V Standby Supply 5 V At 200 mA Patient Leakage Current 50 80 μ A 264 VAC, 63 Hz ~~——~~ Environmental Characteristic Minimum Typical Maximum Units Notes & Conditions Operating Temperature -10 +70 °C Derate Linearly from 100% load at +50 °C to 50% load at +70 °C Storage Temperature -40 +85 °C Humidity 5 95 %RH Non-condensing Integral temperature controlled fan. Fan speed based on temperature of transformer T1, internally monitored. Fan will not Cooling rotate until T1 temperature reaches approx. 60 °C and reaches full speed when T1 temperature reaches approx. 80 °C. ~~po~~ Environmental Characteristic Minimum Typical Maximum Units Notes & Conditions Operating Temperature -10 +70 °C Derate Linearly from 100% load at +50 °C to 50% load at +70 °C Storage Temperature -40 +85 °C Humidity 5 95 %RH Non-condensing Integral temperature controlled fan. Fan speed based on temperature of transformer T1, internally monitored. Fan will not Cooling rotate until T1 temperature reaches approx. 60 °C and reaches full speed when T1 temperature reaches approx. 80 °C. ~~po~~ |Characteristic||Minimum|Typical|Maximum|Units|Notes & Conditions| |---|---|---|---|---|---|---| |Efficiency|||90||%|230 VAC, 100% load| |Isolation|Input to Output|4000|||VAC|2 x MOPP| ||Input to Ground|1500|||VAC|1 X MOPP| ||Output to Ground|1500|||VAC|1 X MOPP| |Switching Frequency|PFC|55|65|75|kHz|Fixed| ||Main Converter|90||300||Variable| ||Standby Converter|124|132|140||Variable| |Hold Up Time||12|20||ms|At 110 VAC & 650 W| |Inrush Current|||30/60||VAC|115 VAC/230 VAC at 25 °C, cold start| |Mean Time Between Failure|||190,000||Hrs|MIL-HDBK-217F, Full load at 25 °C GB| |Weight|||4.4 (2000)||lb (g)|| **www.xppower.com** 2 XP Power Signals & Controls Characteristic Notes & Conditions Remote Sense Compensates for 0.5 V total voltage drop. Inhibit To inhibit apply TTL high signal . AC OK TTL high for normal operation, low upon loss of input power, turn-on delay time 100-1000 ms, turn-off delay time 1 ms minimum EMC: Emissions Phenomenon Standard Test Level Notes & Conditions Conducted EN55011/EN55032 Class B Radiated EN55011/EN55032 Class B Harmonic Current EN61000-3-2 Class A Voltage Fluctuations EN61000-3-3 ~~————_—_—_——~~ EMC: Immunity |Phenomenon|Standard|Test Level|Criteria|Notes & Conditions| |---|---|---|---|---| |ESD|EN61000-4-2|4|A|±8 kV contact, ±15 kV air| |Radiated|EN61000-4-3|10 V/m|A|| |EFT|EN61000-4-4|±2 kV|A|| |Surges|EN61000-4-5|Installation class 3|A|±1 kV differential/ ±2 kV common mode| |Conducted|EN61000-4-6|10 Vrms|A|| |Magnetic Field|EN61000-4-8|30 A/m|A|| |Dips and Interruptions|100 VAC/60 Hz|Dip 30% (70 VAC), 500ms|A|| |||Dip 60% (40 VAC), 100ms|B|| |||Int >95% (0 VAC), 10ms|A|| |||Int 100% (0 VAC), 20ms|A|| |||Int 100% (0 VAC), 5000ms|B|| ||230 VAC/50 Hz|Dip 30% (161 VAC), 500ms|A|| |||Dip 60% (92 VAC), 100ms|A|| |||Int >95% (0 VAC), 10ms|A|| |||Int 100% (0 VAC), 20ms|A|| |||Int 100% (0 VAC), 5000ms|B|| **www.xppower.com** 3 ## **PBR650 Series** yyy ## **AC-DC Power Supplies** ee ## XP Power **==> picture [411 x 434] intentionally omitted <==** **----- Start of picture text -----**<br> Mounting holes, threaded insert<br>for M3*0.5 screws (8 places)<br>|<br>P1<br>4) © CF © Vz k<br>G<br>L<br>N<br>3} -_ [ S| P2 —<br>2.86 4.00<br>(72.6) (101.6)<br>e X _“ @ re =|<br>P3 P3<br>® e eee |<br>in p - ~ a E<br>Vadj JS 2.58 (65.5)<br>6.53 (165.8) 0.87 (22.2) 21<br>3 P3<br>8.00(203.2)<br>|<br>PCB<br>a) © )<br>eo 0 aa<br>: © ©<br>1.95 5<br>(49.5)<br>Input Connector - P1 P3<br>Pin 1 G Pin 1 +V1 Sense<br>Pin 2 L Pin 2 +V1 Sense<br>Pin 3 N Pin 3 AC OK<br>Pin 4 Common Return<br>Pin 5 N/C<br>Pin 6 N/C<br>Pin 7 Inhibit<br>Pin 8 N/C<br>Pin 9 +5V Standby<br>Pin 10 +5V Standby Return<br>Output Connector - P2<br>Pin 1 +V1<br>Pin 2 +V1<br>Pin 3 +V1<br>Pin 4 Com<br>Pin 5 Com<br>Pin 6 Com<br>**----- End of picture text -----**<br> ## ~~**Notes**~~ 1. Dimensions shown in inches [mm] 2. Tolerance 0.02 [0.5] maximum 3. Input connector P1 is Dinkle terminal P/N DT-35C-B01W-03, with nickel plated M3 screws. 5. Connector P3 is JST Header S10B-PHDSS, or equivalent, mating with JST housing PHDR-10VS or equivalent. 6. Weight: 1.4 kg (3.1 lbs.) approx. 7. Maximum penetration of fixing screws is 4 mm from the outer surface of chassis. 4. Output connector P2 is Dinkle Terminal P/N DT-4N-B01W-06 with nickel plated M3.5 screw. **www.xppower.com** 03 Aug 2022
Updated at June 10, 2026
XP Power is a globally recognized leader in the design and manufacture of critical power solutions for the electronics industry. With a steadfast commitment to total quality and in-house engineering expertise, the company delivers highly reliable components that support complex applications across the industrial, healthcare, and technology sectors. Their extensive manufacturing capabilities provide engineers with a broad and dependable source for innovative power products. Our extensive portfolio of XP Power components is heavily focused on robust power and line protection. The core of this offering features a vast selection of high-performance AC/DC converters, designed to meet the rigorous efficiency and footprint demands of modern electronic systems. Complementing these are numerous reliable DC/DC converters, providing versatile options for precise voltage regulation and seamless system integration. Beyond their primary power conversion ranges, XP Power manufactures specialized components to address specific design challenges. Our selection includes essential passive components, such as power line filters for effective EMC and RFI suppression, ensuring signal integrity and strict regulatory compliance. Additionally, we provide dedicated AC/DC LED power supplies tailored for reliable, long-lasting performance in advanced commercial and industrial lighting applications.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →