PBL500PS36C
AC/DC Enclosed Power Supply (PSU), Medical, 1 Outputs, 500 W, 36 VDC, 8.94 A
- Manufacturer: XP POWER
- Product type: AC / DC Enclosed Power Supplies
- SVHC: No SVHC (15-Jan-2018)
- Product Range: PBL500 Series
- No. of Outputs: 1Outputs
- Output Power Max: 500W
- Input Voltage VAC: 80V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 8.94A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 36VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: Medical
| Delivery and price | |
|---|---|
| Units per pack | 5 |
| Price | 251.46 € |
| Current stock | 10+ |
| Lead time | 30 days |
XP Power ## 500 Watts - 450-500W forced air cooled - 250W convection cooled - Class II applications - Medical (BF) safety approvals - U-channel 4” x 7” package - 5V standby & 12V fan supply - Power OK, inhibit & remote sense - Class B conducted & radiated emissions - 3 year warranty Dimensions: The Class II PBL500 series of AC-DC switching power supplies, in a package of just 4 x 7 x 1.56 inches, deliver 450-500 watts of continuous power with forced air cooling or 250 watts with convection cooling. The units are constructed on a U-Channel for mechanical support and heat sinking. A cover and fan assembly can be added during manufacturing. They are designed for medical applications including those needing BF rated insulation with an operation altitude up to 5000 meters. PBL500 (U-channel): 7.1 x 4.00 x 1.56” (180.34 x 101.6 x 39.62 mm) PBL500 (Covered) : 7.1 x 4.00 x 2.64” (180.34 x 101.6 x 67.05 mm) Models & Ratings |Output Voltage<br>V1<br>Output Current V1<br>Standby Supply<br>V2<br>Fan Supply<br>V3<br>Output Power<br>Ripple & Noise(3)<br>Model Number(1)<br>Convection<br>Forced<br>Convection<br>Forced(2)<br>12 V<br>20.83 A<br>37.50 A<br>5.0 V / 2.0 A<br>12.0 V / 0.3 A<br>250 W<br>450 W<br>120 mV<br>PBL500PS12B<br>15 V<br>16.67 A<br>30.00 A<br>150 mV<br>PBL500PS15B<br>18 V<br>13.89 A<br>27.78 A<br>500 W<br>180 mV<br>PBL500PS18B<br>24 V<br>10.42 A<br>20.84 A<br>240 mV<br>PBL500PS24B<br>28 V<br>8.93 A<br>17.86 A<br>280 mV<br>PBL500PS28B<br>36 V<br>8.94 A<br>13.89 A<br>360 mV<br>PBL500PS36B<br>48 V<br>5.21 A<br>10.42 A<br>480 mV<br>PBL500PS48B<br>57 V<br>4.38 A<br>8.78 A<br>570 mV<br>PBL500PS57B<br>~~po _~~<br>~~4~~<br>~~|~~<br>~~FY~~<br>~~|~~<br>~~**ee**~~<br>~~ee~~<br>~~|;~~<br>~~+}~~<br>~~J~~<br>~~ee~~<br>~~ee ee~~<br>~~ee~~<br>~~ee~~<br>~~ee ee~~<br>~~ee ee~~<br>~~ee~~<br>~~ee~~<br>~~ee ee~~<br>~~ee~~<br>~~ee eee~~<br>~~ee ee~~<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~ee ee~~<br>~~ee~~<br>~~ee~~|Output Voltage<br>V1<br>Output Current V1<br>Standby Supply<br>V2<br>Fan Supply<br>V3<br>Output Power<br>Ripple & Noise(3)<br>Model Number(1)<br>Convection<br>Forced<br>Convection<br>Forced(2)<br>12 V<br>20.83 A<br>37.50 A<br>5.0 V / 2.0 A<br>12.0 V / 0.3 A<br>250 W<br>450 W<br>120 mV<br>PBL500PS12B<br>15 V<br>16.67 A<br>30.00 A<br>150 mV<br>PBL500PS15B<br>18 V<br>13.89 A<br>27.78 A<br>500 W<br>180 mV<br>PBL500PS18B<br>24 V<br>10.42 A<br>20.84 A<br>240 mV<br>PBL500PS24B<br>28 V<br>8.93 A<br>17.86 A<br>280 mV<br>PBL500PS28B<br>36 V<br>8.94 A<br>13.89 A<br>360 mV<br>PBL500PS36B<br>48 V<br>5.21 A<br>10.42 A<br>480 mV<br>PBL500PS48B<br>57 V<br>4.38 A<br>8.78 A<br>570 mV<br>PBL500PS57B<br>~~po _~~<br>~~4~~<br>~~|~~<br>~~FY~~<br>~~|~~<br>~~**ee**~~<br>~~ee~~<br>~~|;~~<br>~~+}~~<br>~~J~~<br>~~ee~~<br>~~ee ee~~<br>~~ee~~<br>~~ee~~<br>~~ee ee~~<br>~~ee ee~~<br>~~ee~~<br>~~ee~~<br>~~ee ee~~<br>~~ee~~<br>~~ee eee~~<br>~~ee ee~~<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~ee ee~~<br>~~ee~~<br>~~ee~~|Output Voltage<br>V1<br>Output Current V1<br>Standby Supply<br>V2<br>Fan Supply<br>V3<br>Output Power<br>Ripple & Noise(3)<br>Model Number(1)<br>Convection<br>Forced<br>Convection<br>Forced(2)<br>12 V<br>20.83 A<br>37.50 A<br>5.0 V / 2.0 A<br>12.0 V / 0.3 A<br>250 W<br>450 W<br>120 mV<br>PBL500PS12B<br>15 V<br>16.67 A<br>30.00 A<br>150 mV<br>PBL500PS15B<br>18 V<br>13.89 A<br>27.78 A<br>500 W<br>180 mV<br>PBL500PS18B<br>24 V<br>10.42 A<br>20.84 A<br>240 mV<br>PBL500PS24B<br>28 V<br>8.93 A<br>17.86 A<br>280 mV<br>PBL500PS28B<br>36 V<br>8.94 A<br>13.89 A<br>360 mV<br>PBL500PS36B<br>48 V<br>5.21 A<br>10.42 A<br>480 mV<br>PBL500PS48B<br>57 V<br>4.38 A<br>8.78 A<br>570 mV<br>PBL500PS57B<br>~~po _~~<br>~~4~~<br>~~|~~<br>~~FY~~<br>~~|~~<br>~~**ee**~~<br>~~ee~~<br>~~|;~~<br>~~+}~~<br>~~J~~<br>~~ee~~<br>~~ee ee~~<br>~~ee~~<br>~~ee~~<br>~~ee ee~~<br>~~ee ee~~<br>~~ee~~<br>~~ee~~<br>~~ee ee~~<br>~~ee~~<br>~~ee eee~~<br>~~ee ee~~<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~ee ee~~<br>~~ee~~<br>~~ee~~|Output Voltage<br>V1<br>Output Current V1<br>Standby Supply<br>V2<br>Fan Supply<br>V3<br>Output Power<br>Ripple & Noise(3)<br>Model Number(1)<br>Convection<br>Forced<br>Convection<br>Forced(2)<br>12 V<br>20.83 A<br>37.50 A<br>5.0 V / 2.0 A<br>12.0 V / 0.3 A<br>250 W<br>450 W<br>120 mV<br>PBL500PS12B<br>15 V<br>16.67 A<br>30.00 A<br>150 mV<br>PBL500PS15B<br>18 V<br>13.89 A<br>27.78 A<br>500 W<br>180 mV<br>PBL500PS18B<br>24 V<br>10.42 A<br>20.84 A<br>240 mV<br>PBL500PS24B<br>28 V<br>8.93 A<br>17.86 A<br>280 mV<br>PBL500PS28B<br>36 V<br>8.94 A<br>13.89 A<br>360 mV<br>PBL500PS36B<br>48 V<br>5.21 A<br>10.42 A<br>480 mV<br>PBL500PS48B<br>57 V<br>4.38 A<br>8.78 A<br>570 mV<br>PBL500PS57B<br>~~po _~~<br>~~4~~<br>~~|~~<br>~~FY~~<br>~~|~~<br>~~**ee**~~<br>~~ee~~<br>~~|;~~<br>~~+}~~<br>~~J~~<br>~~ee~~<br>~~ee ee~~<br>~~ee~~<br>~~ee~~<br>~~ee ee~~<br>~~ee ee~~<br>~~ee~~<br>~~ee~~<br>~~ee ee~~<br>~~ee~~<br>~~ee eee~~<br>~~ee ee~~<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~ee ee~~<br>~~ee~~<br>~~ee~~| |---|---|---|---| |~~**Notes**~~|||| |_1. For covered version with integral fan, replace B in the part number with C, e.g PBL500PS12C. V3 not available on covered version._|||| |_2. 250 W without moving air or 450-500 W with 30 CFM forced air provided by the user. 450-500 W for ‘-C’ version_|||| |_3. Ripple and noise is the maximum peak-to-peak voltage value measured at the output with 20 MHz bandwidth, at rated line voltage and output load, and with a 10μF _|||| |_tantalum capacitor in parallel with a 0.1μF ceramic capacitor._|||| |PBL500PSxxC<br>PBL500PS12C, PBL500PS15C<br>PBL500PSxxB<br>50<br>100<br>500<br>250<br>300<br>350<br>400<br>450<br>200<br>150<br>Output Power (W)<br>0<br>**Temperature Derating Curve**<br>po<br>HERE EES<br>PEEREEE<br>+--+ FN<br>Pt tT ttt tt ytENO<br>Pit ttt tT ty etry TEN<br>PETttt tetee Ey Ey<br>Pit tt tt tye eT TT<br>PET TTT TTT tT Ty yt|||| |0<br>-10<br>10<br>20<br>40<br>30<br>50<br>60||70|| |Ambient Temperature (ºC)|||| _1. For covered version with integral fan, replace B in the part number with C, e.g PBL500PS12C. V3 not available on covered version._ _2. 250 W without moving air or 450-500 W with 30 CFM forced air provided by the user. 450-500 W for ‘-C’ version_ _3. Ripple and noise is the maximum peak-to-peak voltage value measured at the output with 20 MHz bandwidth, at rated line voltage and output load, and with a 10 μ F tantalum capacitor in parallel with a 0.1 μ F ceramic capacitor._ **www.xppower.com** 1 XP Power ## Input |Characteristic|Minimum|Typical|Maximum|Units|Notes & Conditions| |---|---|---|---|---|---| |Input Voltage|80||264|VAC|Derate to 90% at 85 VAC & 80%at 80 VAC| |Input Frequency|47||63|Hz|| |Input Current - Full Load||5.2/2.6||A (rms)|115/230 VAC, 60/50 Hz| |No Load Input Power|||1|W|When inhibit used| |Inrush Current||30/60||A|115 VAC/230 VAC at 25 °C, cold start| |Input Protection|Internal fuse fitted in line and neutral||||| ## Output |Characteristic|Minimum|Typical|Maximum|Units|Notes & Conditions| |---|---|---|---|---|---| |Output Voltage (V1)|12||57|VDC|See Models and Ratings table| |Tolerance|||±2|%|Line and Load Regulation, 0.1% minimum load required to meet<br>specification| |Transient Response|||4|%|Recovery within 1% in less than 500μs<br>for a 25% step load change| |Ripple & Noise|||1|% pk-pk|20 MHz bandwidth, see model table notes| |Overvoltage Protection|112||140|%|Latching| |Overcurrent Protection|105||140|%|Trip & restart characteristic| |Thermal Shutdown|||||Protected for overtemperature conditions, latching| |Temperature Coefficient|||±0.04|%/°C|| |5 V Standby Supply (V2)||5||V|At 2.0 A| |Fan Supply (V3)||12||V|At 300 mA| |Patient Leakage Current||50|80|μA|264 VAC, 63 Hz| ## Environmental |Characteristic|Minimum|Typical|Maximum|Units|Notes & Conditions| |---|---|---|---|---|---| |Operating Temperature|-10||+70|°C|Derate Linearly from 100% load at +50 °C to 50% load at +70 °C| |Storage Temperature|-40||+85|°C|| |Humidity|5||95|%RH|Non-condensing| |Cooling (-C version)|||||Integral temperature controlled fan. Fan speed based on<br>temperature of transformer T1, internally monitored. Fan will not<br>rotate until T1 temperature reaches approx. 30 °C and reaches full<br>speed when T1 temperature reaches approx. 60 °C.| |Operating Altitude|||5000|m|| ## General |Characteristic||Minimum|Typical|Maximum|Units|Notes & Conditions| |---|---|---|---|---|---|---| |Efficiency|||90||%|230 VAC, 100% load| |Isolation|Input to Output|4000|||VAC|2 x MOPP| ||Input to Case|4000|||VAC|2 x MOPP| ||Output to Case|1500|||VAC|1 x MOPP| |Switching Frequency|PFC|55|65|75|kHz|Fixed| ||Main Converter|90||300||Variable| ||Standby Converter|80||120||Variable| |Hold Up Time||20|||ms|At 110 VAC & 500 W| |Power Density||||11.2|W/in3|| |Mean Time Between Failure|||100,000||Hrs|MIL-HDBK-217F, Full load at 25 °C GB| |Weight|||2.23 (1011.5)||lb (g)|PBL500PSxxB| ||||2.52 (1143.0)|||PBL500PSxxC| **www.xppower.com** 2 XP Power ## Signals & Controls Characteristic Notes & Conditions Remote Sense Compensates for 0.5 V total voltage drop. Inhibit To inhibit, apply TTL high signal. Power OK (POK) TTL high for normal operation, monitors input bus and output voltage. Turn on delay 100-1000ms, 1ms warning of loss of output following loss of input power. EMC: Emissions Phenomenon Standard Test Level Notes & Conditions Conducted EN55011 Class B Radiated EN55011 Class B Harmonic Current EN61000-3-2 Class A Voltage Fluctuations EN61000-3-3 ~~———_—_—_—~~ EMC: Immunity |Phenomenon|Standard|Test Level|Criteria|Notes & Conditions| |---|---|---|---|---| |ESD|EN61000-4-2|4|A|±8 kV contact, ±15 kV air| |Radiated|EN61000-4-3|10 V/m|A|| |EFT|EN61000-4-4|±2 kV|A|| |Surges|EN61000-4-5|3|A|+/-2kV L-N| |Conducted|EN61000-4-6|10 Vrms|A|| |Magnetic Field|EN61000-4-8|30 A/m|A|| |Dips and Interruptions|100 VAC/50 Hz|Dip 30% (70 VAC), 500ms|A|| |||Dip 60% (40 VAC), 100ms|B|| |||Int >95% (0 VAC), 10ms|A|| |||Int 100% (0 VAC), 20ms|A|| |||Int 100% (0 VAC), 5000ms|B|| ||240 VAC/50 Hz|Dip 30% (168 VAC), 500ms|A|| |||Dip 60% (96 VAC), 100ms|A|| |||Int >95% (0 VAC), 10ms|A|| |||Int 100% (0 VAC), 20ms|A|| |||Int 100% (0 VAC), 5000ms|B|| **www.xppower.com** 3 **PBL500 Series AC-DC Power Supplies** e ~~e~~ XP Power ## **PBL500PSxxB** **==> picture [517 x 460] intentionally omitted <==** **----- Start of picture text -----**<br> B: Mounting hole, threaded inserts for M3*0.5 screws (8 places)<br>A: Mounting hole, threaded inserts for #6-32 screws (8 places)<br>0.93<br>(23.5)<br>eee—_ | Al<br>4.21<br>(107.0)<br>L rT | |l Hse<br>Sc oo<br>2.36<br>(60.0) | P4<br>P2<br>B |[1 c) le_«<br>A | | A B ca u) P3<br>P3<br>@ @—}—-—_ -=e<br>P4<br>|<br>Ol<br>0.51 (13.0) 3.94 (100.1)<br>0.59 (15.0) 5.91 (150.0)<br>1.56<br>B<br>(39.5)<br>2. DN BBD<br>0.82<br>(20.8)<br>: OA<br>0.42<br>6.54 (166.0) 0.28 (7.0)<br>(10.8)<br>7.09 (180.0)<br>Input Connector - P1 Output Connector - P2 Signals and Controls -P3 Output Connector - P4<br>Pin 1 L Pin 1 +V1 Pin 1 Common Return Pin 5 Inhibit Pin 1 Common Return<br>Pin 2 N Pin 2 -V1 (common return) Pin 2 +V1 Sense Pin 6 +5V Standby Pin 2 +V3<br>Pin 3 -V1 Sense Pin 7 +5V Standby<br>Pin 4 POK Pin 8 Common Return<br>**----- End of picture text -----**<br> ## ~~**Notes**~~ 1. Dimensions shown in inches [mm] 2. Tolerance 0.02 [0.5] maximum 3. Input connector P1 is Dinkle terminal P/N DT-35C-B01W-03, with nickel plated M3 screws. 6. Fan connector P4 is JST header S2B-ZR-3.4 or equivalent, mating with JST housing ZHR-2 or equivalent. 7. Weight: 1.0 Kg (2.23 lbs.) approx. 8. Maximum penetration of fixing screws is 4 mm from the outer surface of chassis. 4. Output connector P2 is M4x0.7 screw connections. 5. Connector P3 is Molex header 87833-08 or equivalent, mating with Molex housing 51110-0850 or equivalent. **www.xppower.com** 4 XP Power ## Mechanical Details ~~Eli~~ ## **PBL500PSxxC** **==> picture [477 x 455] intentionally omitted <==** **----- Start of picture text -----**<br> B: Mounting hole, threaded inserts for M3*0.5 screws (8 places)<br>A: Mounting hole, threaded inserts for #6-32 screws (8 places)<br>ey a<br>0.93<br>(23.5) “& B. @ &<br>4.21<br>(107.0) a<br>2.36<br>(60.0)<br>P2<br>P3<br>P3<br>ee See<br>0.51 (13.0) [oT 3.94 (100.0)<br>0.59 (15.0) 5.91 (150.0)<br>nn 0.67 (17.0)<br>2.64<br>PO (67.0)<br>S<br>1.56<br>1.85<br>(39.5)<br>(47.0)<br>0.82<br>(20.8)<br>| m ba |<br>0.42<br>6.54 (166.0) 0.28 (7.0)<br>(10.8)<br>7.09 (180.0)<br>Input Connector - P1 Output Connector - P2 Signals and Controls -P3<br>Pin 1 L Pin 1 +V1 Pin 1 Common Return Pin 5 Inhibit<br>Pin 2 N Pin 2 -V1 (common return) Pin 2 +V1 Sense Pin 6 +5V Standby<br>Pin 3 -V1 Sense Pin 7 5V Standby<br>Pin 4 AC OK Pin 8 Common Return<br>**----- End of picture text -----**<br> ## ~~**Notes**~~ 1. Dimensions shown in inches [mm] 2. Tolerance 0.02 [0.5] maximum 6. Weight: 1.14 Kgs. (2.52 lbs.) approx. 7. Maximum penetration of fixing screws is 4 mm from the outer surface of chassis. 3. Input connector P1 is Dinkle terminal P/N DT-35C-B01W-03, with nickel plated M3 screws. 4. Output connector P2 is M4x0.7 screw connections. 5. Connector P3 is Molex header 87833-08 or equivalent, mating with Molex housing 51110-0850 or equivalent. **www.xppower.com** 26 January 2022
Updated at June 10, 2026
XP Power is a globally recognized leader in the design and manufacture of critical power solutions for the electronics industry. With a steadfast commitment to total quality and in-house engineering expertise, the company delivers highly reliable components that support complex applications across the industrial, healthcare, and technology sectors. Their extensive manufacturing capabilities provide engineers with a broad and dependable source for innovative power products. Our extensive portfolio of XP Power components is heavily focused on robust power and line protection. The core of this offering features a vast selection of high-performance AC/DC converters, designed to meet the rigorous efficiency and footprint demands of modern electronic systems. Complementing these are numerous reliable DC/DC converters, providing versatile options for precise voltage regulation and seamless system integration. Beyond their primary power conversion ranges, XP Power manufactures specialized components to address specific design challenges. Our selection includes essential passive components, such as power line filters for effective EMC and RFI suppression, ensuring signal integrity and strict regulatory compliance. Additionally, we provide dedicated AC/DC LED power supplies tailored for reliable, long-lasting performance in advanced commercial and industrial lighting applications.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →