Image not available
Illustrative purposes only
PAD55A
AC/DC Enclosed Power Supply (PSU), ITE, 1 Outputs, 51.38 W, 13.8 V, 3.5 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: TIGER POWER SUPPLIES
- Product type: AC / DC Enclosed Power Supplies
- No. of Outputs: 1Outputs
- Output Power Max: 51.38W
- Input Voltage VAC: 88V AC to 264V AC
- Power Supply Approvals: ITE
- Power Supply Output Type: Fixed
- Output Current - Output 1: 3.5A
- Output Voltage - Output 1: 13.8V
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 44.1 € |
| Current stock | 10+ |
| Lead time | 7 days |
**-** P **AD 55 series** ## ppliplies **-** 55W Single Output with Battery Charger(UPS Function) P **AD** ~~I~~ ## ■ - ‧ - ‧ - ‧ - ‧ - ‧ |**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**SAFETY STANDARDS**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**BATTERY LOW**<br>**AC CURRENT (Typ.)**<br>800ms, 50ms/230VAC 1600ms, 50ms/115VAC at full load<br>80ms/230VAC 16ms/115VAC at full load<br>88 ~ 264VAC 124 ~ 370VDC<br>47 ~ 63Hz<br>71%<br>74%<br>CH1:31.74 ~ 37.26V<br>1.6A/115VAC 1A/230VAC<br>COLD START 20A/115VAC 40A/230VAC<br><1mA / 240VAC<br>105 ~ 150% rated output power<br>CH1:15.87 ~ 18.63V<br>Protection type : AC Charging Mode : Hiccup mode, recovers automatically after fault condition is removed<br>UPS Mode : Protected by internal fuse<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>9.5 ~ 11V<br>20 ~ 22V<br>UL62368-1, TUV EN62368-1, AS/NZS 62368.1,<br>approved<br>EAC TP TC 004<br>Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3,<br>EAC TP TC 020<br>Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A,<br>EAC TP TC 020<br>-10 ~ +60℃(Refer to "Derating Curve")<br>20 ~ 90% RH non-condensing<br>-20 ~ +85℃, 10 ~ 95% RH<br>±0.03%/℃(0~50℃) on CH1 output<br>10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes<br>304.3K hrs min. MIL-HDBK-217F (25℃)<br>159*97*38mm (L*W*H)<br>0.5Kg; 24pcs/12.6Kg/<br>CUFT<br>0.83<br>**DC ALARM SIGNAL(OPTIONAL)**<br>**FUNCTION**<br>Battery low under charge voltage 82.5%±2% CN1 PIN1<br>Normal 0.8V max. Abnormal 5V±0.5V<br>AC fail CN1 PIN2<br>PAD-55B<br>27.6V<br>CH1<br>1.8A<br>0 ~ 2A<br>53.92W<br>100mVp-p<br>CH1: 24 ~ 29V<br>±1.0%<br>±0.5%<br>±0.5%<br>26.5V<br>CH2<br>0.16A<br>--------<br>--------<br>--------<br>--------<br>--------<br>13.4V<br>CH2<br>0.23A<br>--------<br>--------<br>--------<br>--------<br>--------<br>PAD-55A<br>13.8V<br>3.5A<br>0 ~ 4A<br>51.38W<br>100mVp-p<br>CH1: 12 ~ 14.5V<br>±1.0%<br>±0.5%<br>±0.5%<br>**RIPPLE & NOISE (max.)Note.2**<br>**VOLTAGE TOLERANCENote.3**<br>**ENVIRONMENT**<br>**PROTECTION**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH<br>**SAFETY &**<br>**EMC**<br>**(Note 4)**<br>℃<br><br><br><br><br><br><br><br><br><br><br>http://www.meanwell.com)<br>℃℃<br>CH1<br>**OUTPUT NUMBER**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>~~===~~|**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**SAFETY STANDARDS**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**BATTERY LOW**<br>**AC CURRENT (Typ.)**<br>800ms, 50ms/230VAC 1600ms, 50ms/115VAC at full load<br>80ms/230VAC 16ms/115VAC at full load<br>88 ~ 264VAC 124 ~ 370VDC<br>47 ~ 63Hz<br>71%<br>74%<br>CH1:31.74 ~ 37.26V<br>1.6A/115VAC 1A/230VAC<br>COLD START 20A/115VAC 40A/230VAC<br><1mA / 240VAC<br>105 ~ 150% rated output power<br>CH1:15.87 ~ 18.63V<br>Protection type : AC Charging Mode : Hiccup mode, recovers automatically after fault condition is removed<br>UPS Mode : Protected by internal fuse<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>9.5 ~ 11V<br>20 ~ 22V<br>UL62368-1, TUV EN62368-1, AS/NZS 62368.1,<br>approved<br>EAC TP TC 004<br>Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3,<br>EAC TP TC 020<br>Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A,<br>EAC TP TC 020<br>-10 ~ +60℃(Refer to "Derating Curve")<br>20 ~ 90% RH non-condensing<br>-20 ~ +85℃, 10 ~ 95% RH<br>±0.03%/℃(0~50℃) on CH1 output<br>10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes<br>304.3K hrs min. MIL-HDBK-217F (25℃)<br>159*97*38mm (L*W*H)<br>0.5Kg; 24pcs/12.6Kg/<br>CUFT<br>0.83<br>**DC ALARM SIGNAL(OPTIONAL)**<br>**FUNCTION**<br>Battery low under charge voltage 82.5%±2% CN1 PIN1<br>Normal 0.8V max. Abnormal 5V±0.5V<br>AC fail CN1 PIN2<br>PAD-55B<br>27.6V<br>CH1<br>1.8A<br>0 ~ 2A<br>53.92W<br>100mVp-p<br>CH1: 24 ~ 29V<br>±1.0%<br>±0.5%<br>±0.5%<br>26.5V<br>CH2<br>0.16A<br>--------<br>--------<br>--------<br>--------<br>--------<br>13.4V<br>CH2<br>0.23A<br>--------<br>--------<br>--------<br>--------<br>--------<br>PAD-55A<br>13.8V<br>3.5A<br>0 ~ 4A<br>51.38W<br>100mVp-p<br>CH1: 12 ~ 14.5V<br>±1.0%<br>±0.5%<br>±0.5%<br>**RIPPLE & NOISE (max.)Note.2**<br>**VOLTAGE TOLERANCENote.3**<br>**ENVIRONMENT**<br>**PROTECTION**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH<br>**SAFETY &**<br>**EMC**<br>**(Note 4)**<br>℃<br><br><br><br><br><br><br><br><br><br><br>http://www.meanwell.com)<br>℃℃<br>CH1<br>**OUTPUT NUMBER**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>~~===~~|PAD-55A<br>~~===~~|PAD-55A<br>~~===~~|PAD-55B<br>~~===~~|PAD-55B<br>~~===~~| |---|---|---|---|---|---| ||**OUTPUT NUMBER**<br>~~===~~|CH1<br>~~===~~|CH2<br>~~===~~|CH1<br>~~===~~|CH2<br>~~===~~| ||**DC VOLTAGE**<br>~~===~~|13.8V<br>~~===~~|13.4V<br>~~===~~|27.6V<br>~~===~~|26.5V<br>~~===~~| ||**RATED CURRENT**<br>~~===~~|3.5A<br>~~===~~|0.23A<br>~~===~~|1.8A<br>~~===~~|0.16A<br>~~===~~| ||**CURRENT RANGE**<br>~~===~~|0 ~ 4A<br>~~===~~|--------<br>~~===~~|0 ~ 2A<br>~~===~~|--------<br>~~===~~| ||**RATED POWER**<br>~~===~~|51.38W<br>~~===~~||53.92W<br>~~===~~|| ||**RIPPLE & NOISE (max.)Note.2**<br>~~===~~|100mVp-p<br>~~===~~|--------<br>~~===~~|100mVp-p<br>~~===~~|--------<br>~~===~~| ||**VOLTAGE ADJ. RANGE**<br>~~===~~|CH1: 12 ~ 14.5V<br>~~===~~||CH1: 24 ~ 29V<br>~~===~~|| ||**VOLTAGE TOLERANCENote.3**<br>~~===~~|±1.0%<br>~~===~~|--------<br>~~===~~|±1.0%<br>~~===~~|--------<br>~~===~~| ||**LINE REGULATION**<br>~~===~~|±0.5%<br>~~===~~|--------<br>~~===~~|±0.5%<br>~~===~~|--------<br>~~===~~| ||**LOAD REGULATION**<br>~~===~~|±0.5%<br>~~===~~|--------<br>~~===~~|±0.5%<br>~~===~~|--------<br>~~===~~| ||**SETUP, RISE TIME**<br>~~===~~|800ms, 50ms/230VAC 1600ms, 50ms/115VAC at full load<br>~~===~~|||| ||**HOLD UP TIME (Typ.)**|80ms/230VAC 16ms/115VAC at full load|||| ||**VOLTAGE RANGE**|88 ~ 264VAC 124 ~ 370VDC|||| ||**FREQUENCY RANGE**|47 ~ 63Hz|||| ||**EFFICIENCY (Typ.)**|71%||74%|| ||**AC CURRENT (Typ.)**|1.6A/115VAC 1A/230VAC|||| ||**INRUSH CURRENT (Typ.)**|COLD START 20A/115VAC 40A/230VAC|||| ||**LEAKAGE CURRENT**|<1mA / 240VAC|||| ||**OVERLOAD**|105 ~ 150% rated output power<br>Protection type : AC Charging Mode : Hiccup mode, recovers automatically after fault condition is removed<br>UPS Mode : Protected by internal fuse|||| ||**OVER VOLTAGE**|CH1:31.74 ~ 37.26V<br>CH1:15.87 ~ 18.63V<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed|||| ||**BATTERY LOW**|9.5 ~ 11V||20 ~ 22V|| ||**DC ALARM SIGNAL(OPTIONAL)**|Battery low under charge voltage 82.5%±2% CN1 PIN1<br>Normal 0.8V max. Abnormal 5V±0.5V<br>AC fail CN1 PIN2|||| ||**WORKING TEMP.**|-10 ~ +60℃(Refer to "Derating Curve")|||| ||**WORKING HUMIDITY**|20 ~ 90% RH non-condensing|||| ||**STORAGE TEMP., HUMIDITY**|-20 ~ +85℃, 10 ~ 95% RH|||| ||**TEMP. COEFFICIENT**|±0.03%/℃(0~50℃) on CH1 output|||| ||**VIBRATION**|10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes|||| ||**SAFETY STANDARDS**|UL62368-1, TUV EN62368-1, AS/NZS 62368.1,<br>approved<br>EAC TP TC 004|||| ||**WITHSTAND VOLTAGE**|I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC|||| ||**ISOLATION RESISTANCE**|I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH|||| ||**EMC EMISSION**|Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3,<br>EAC TP TC 020|||| ||**EMC IMMUNITY**|Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A,<br>EAC TP TC 020|||| ||**MTBF**|304.3K hrs min. MIL-HDBK-217F (25℃)|||| ||**DIMENSION**|159*97*38mm (L*W*H)|||| ||**PACKING**|0.5Kg; 24pcs/12.6Kg/<br>CUFT<br>0.83|||| ||℃<br><br><br><br><br><br><br><br><br><br><br>http://www.meanwell.com)<br>℃℃||||| Tiger Power Supplies, Henley-On-Thames, RG9 1UY, UK, T: (0) 1491 522 711 E: info@TigerPowerSupplies.com www.TigerPowerSupplies.com **-** P **AD 55 series** 55W Single Output with Battery Charger(UPS Function) ## **Mechanical Specification** **==> picture [490 x 654] intentionally omitted <==** **----- Start of picture text -----**<br> 4.5 152.5<br>79.5<br>:<br>FAN<br>18.2CFM min.<br>—<br>1<br>2<br>3<br>f ig<br>4<br>5<br>6<br>7<br>t et ec - —-<br>S 8<br>be a ____, —_4—+ |<br>4.5<br>ef 24 78<br>159<br>6.5 e T 150 Terminal Pin No. Assignment :<br>Pin No. Assignment Pin No. Assignment<br>1 AC/L 5 DC OUTPUT +V<br>é\e ~ | C4 ‘I a. 2 AC/N * 6 BAT. +<br>N ee<br>3 FG 7 BAT.-/COM<br>4 DC OUTPUT COM 8 NC<br>= = ° a --r— * |<br>22 117<br>_ <r. — | PF<br>fosc : 45KHz<br>Block Diagram BAT. CHARGER<br>& oO B+<br>BACK UP<br>RECTIFIERS RECTIFIERS<br>EMI POWER +V<br>I/P FILTER & SWITCHING & COM/B-<br>FILTER FILTER<br>FG<br>PWM DETECTION<br>O.L.P.<br>CONTROL CIRCUIT<br>Derating Curve |_| Static Characteristics (A)<br>14 300<br>100 +13.8V<br>13 250<br>80 With 18.2CFM min.(10cm)<br>12 200<br>70<br>60 11 150<br>50<br>NO FAN 10 100<br>40<br>9 50<br>20<br>8 +13.8V 25<br>-10 0 10 20 30 40 50 60 (HORIZONTAL) 60 80 100 120 140 160 180 200 220 240 264<br>AMBIENT TEMPERATURE ( ℃ ) INPUT VOLTAGE (V) 60Hz<br>3.5<br>ψ<br>2-M3<br>3-M3<br>ψ<br>3.5<br>10cm<br>7<br>3.5<br>8.25 65<br>7<br>84.5 9<br>6.5<br>9 18.5 9<br>18 3.5 28.5 38<br>LOAD (%) OUTPUT VOLTAGE (V) OUTPUT RIPPLE (mVp-p)<br>**----- End of picture text -----**<br> ## TIGER POWER PRODUCTS – QUALITY & RELIABILITY Tiger Power Supplies, Henley-On-Thames, RG9 1UY, UK, T: (0) 1491 522 711 E: info@TigerPowerSupplies.com www.TigerPowerSupplies.com
Updated at February 9, 2023
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →