Image not available
Illustrative purposes only
P6100Z2100-00-0
PID Controller, 2300 Series, 1/32 DIN, SSR, Relay Outputs, Red Display, 100 to 240 Vac
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: WEST INSTRUMENTS
- Product type: Temperature Controllers
- Thermocouple Type:B, C, J, K, L, N, R, S, T; Operating Temperature Max:55°C; Operating Temperature Min:0°C; Temperature Accuracy ±:-; Output Voltage Max:240VAC; Output Voltage Min:-; Produc
- Product Range: 6100
- Thermocouple Type: B, C, J, K, L, N, R, S, T
- Output Voltage Max: 240VAC
- Output Voltage Min: -
- Temperature Accuracy ±: -
- Operating Temperature Max: 55°C
- Operating Temperature Min: 0°C
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 303.37 € |
| Current stock | 10+ |
| Lead time | 30 days |
Product **Specification**
## **West P6100[1] /16 Din Process Controller**
With its improved interface, technical functionality and field flexibility, the West 6100 gives you the best in comprehensive control for most temperature and process control loops.
- **Jumperless Configuration** • **Auto or Manual Tuning**
- **Auto Detected Hardware** • **Heat/Cool Operation**
- **Process & Loop Alarms** • **Ramping Setpoint**
- **Modbus & ASCII Comms** • **Remote/Dual Setpoint Options**
## CE
## **Technical Data**
**Features**
|Control Types|Full PID with Pre-tune, Self-tune, manual tuning, or On-Off control. Heat onlyor heat & cool|
|---|---|
|Auto/Manual|Selectable from frontpanel or via digital input,with bumpless transfer|
|Output Configuration|Up to 3 possible, for control, alarm, 24VDC transmitter power supply or retransmit of process|
||value orsetpoint|
|Alarm 1 & 2 Types|Process high, process low, SP deviation, band, logical OR / AND. Also 1 loop alarm for|
||process controlsecurity. Process alarmshave adjustablehysteresis.|
|Human Interface|4 button operation, dual 4 digit 10mm & 8mm high LED displays, optional choice of colours|
||(Red/Red,Red/Green, Green/Red orGreen/Green), plus 5LED indicators|
|PC Configuration|Off-line configuration from PC serial port to dedicated config socket (comms option not|
||required).ConfigurationSoftwarefor Windows 98 or higher. West Part Number: PS1-CON|
|**Input**||
|Thermocouple|J, K, C, R, S, T, B, L, N & PtRh20%vsPtRh40%.|
|RTD|3 Wire PT100, 50Ω per lead maximum(balanced)|
|DC Linear|0 to 20mA, 4 to 20mA, 0 to 50mV, 10 to 50mV, 0 to 5V, 1 to 5V, 0 to 10V, 2 to 10V.|
||Scaleable-1999to 9999,withadjustable decimalpoint|
|Impedance|>10MΩfor Thermocouple and mV ranges, 47KΩfor V ranges and 5Ωfor mA ranges|
|Accuracy|±0.1% of input range ±1 LSD(T/C CJC better than 1°C)|
|Sampling|4per second, 14 bit resolution approximately|
|Sensor Break Detection|<2 seconds (except zero based DC ranges), control O/P’s turn off, high alarms activate for T/C|
||andmV ranges,lowalarms activatefor RTD,mAor V ranges|
|**Outputs & Options**||
|Control & Alarm Relays|Contacts SPDT 2 Ampresistive at 240V AC, >500,000 operations|
|Control SSR Driver Outputs|Drive capability>10V DC in 500Ωminimum|
|Triac Outputs|0.01 to 1 AmpAC, 20 to 280Vrms, 47 to 63Hz|
|DC Linear Outputs|0 to 20mA, 4 to 20mA into 500Ωmax, 0 to 10V, 2 to 10V, 0 to 5V into 500Ωmin.|
||Control outputs have 2% over/under drive applied. Accuracy ±0.25% at 250Ω(degrades|
||linearlyto 0.5%for increasing burden to specifiedlimits)|
|Transmitter Power Supply|Output 24VDC(nominal)into 910Ωminimum topower external devices|
|Communications|2 Wire RS485, 1200 to 19200 Baud, Modbus and ASCIIprotocol(selectable)|
|Digital Input|Selects between 2 setpoints or Auto/Manual control. Volt free or TTL input|
|Remote Setpoint Input|0 to 20mA, 4 to 20mA, 0 to 5V, 1 to 5V, 0 to 10V or 2 to 10V. Scaleable -1999 to 9999.|
||Local/Remote setpointselectedfrom frontpanel|
|**Operating & Environmental**||
|Temperature & RH|0 to 55°C(-20 to 80°C storage), 20% to 95% RH non-condensing|
|Power Supply|100 to 240V 50/60Hz 7.5VA(optional 20 to 48V AC 7.5VA/22 to 65V DC 5 watts)|
|Front Panel Protection|IEC IP66(Behindpanelprotection is IP20)|
|Standards|CE, UL & ULC recognised|
Control Types Auto/Manual Output Configuration
In accordance with our policy of continuous improvement, we reserve the right to change specifications from those shown in this document P6100 Spec s **heet - 06/04**
_**West Instruments Tel:** +44 (0) 1273 606271_ _**e-mail:** info@westinstruments.com The Hyde Business Park_ _**Fax:** +44 (0) 1273 609990_ _**Web:** www.westinstruments.com Brighton BN2 4JU, UK_
**==> picture [83 x 91] intentionally omitted <==**
**----- Start of picture text -----**<br>
Cut-out<br>45 x 45mm<br>+0.5 –0.0<br>45 x 45mm<br>+0.5 –0.0<br>**----- End of picture text -----**<br>
**==> picture [514 x 654] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|Dimensions|10mm (approx)|Cut-out|
|48mm|110mm|
|ee|eee|
|45 x 45mm|
|+0.5 –0.0|
|45 x 45mm|
|+0.5 –0.0|
|AUTO|f=]|
|Connection Details|OPTION|3|Field Reconfiguration|
|8|ote|
|Input|
|2|-|+|Transmitter|PSU|
|Jumper-free configuration for any type|
|3|NiC|C|N/O|Relay|m|(no extra parts required)|
|e349a|-|+|DCorssRDrive|S&|wy©|Option Slot 1|Relay Output...........................|Part Number PO1-C10|
|2|38|5|9|<2|op|Linear mA/V DC Output ..........|PO1-C21|
|9(35|[-—+-0]|BME|—|8|8|&nN|SSR Driver Output ..................|PO1-C50|
|{o)4=|o=—~|8|||~—|oSxroON|GszoON|fo)ZYG|v|Triac Output ............................|Option Slot 2|Part Number PO1-C80|
|Relay Output...........................|PO2-C10|
|c|~|~|B =|Linear mA/V DC Output ..........|PO2-C21|
|~Z2(+|1|!|a)|fo|——|2m|+9|5|SSR Driver Output ..................|PO2-C50|
|13a|<|-|=|-|-|Triac Output ............................|PO2-C80|
|G2|+|4|5|||14}|~—|5 é|w|2|Option Slot 3|Part Number|
|>|-|6|||a]|fis]|fie|te|FS|DP|+|z|Relay Output...........................|PO2-C10|
|rc|C-|—-|ao|wv|
|a-|8&|88|iS)a|+|=|DC|or SSR|Drive|aoS|28=|QP|Linear mA/V DC Output ..........SSR Driver Output ..................|PO2-C21 PO2-C50|
|3|<|oO|fo)|x=]|24VDC Transmitter PSU........|PO2-W08|
|>|3|2||I~l|Triac|g|5|Option Slot A|Part Number|
|®|NiO|©|NIC|Relay|3|Digital Input............................|PA1-W03|
|Remote Setpoint Input (Basic)|PA1-W04|
|OP2-N/O|C|N/O-OP4|Dual|Relay|RS485 Comms.......................|PA1-W06|
|Order Code|OPTION|2|
|P6100|-|x|-|x|-|x|-|x|-|x|-|x|-|x|
|Input Type|Display Colour|
|3 Wire RTD or DC mV|1|0|Red Upper & Lower|
|Thermocouple|2|1|Green Upper & Lower|
|DC mA|3|2|Red Upper, Green Lower|
|DC Voltage|4|3|Green Upper, Red Lower|
|Option Slot 1|Power Supply|
|Not fitted|0|0|100-240V AC|
|Relay|1|2|24-48V AC or DC|
|DC for SSR|2|Option Slot A|
|DC 0-10V|3|0|Not fitted|
|DC 0-20mA|4|1|RS485 Communications|
|DC 0-5V|5|3|Digital Input|
|DC 2-10V|6|4|Basic Remote Setpoint Input|
|DC 4-20mA|7|Option Slot 3|
|Triac|8|0|Not fitted|
|Option Slot 2|1|Relay|
|Not fitted|0|2|DC Driver for SSR|
|Relay|1|3|DC 0-10V|
|DC Driver for SSR|2|4|DC 0-20mA|
|DC 0-10V|3|5|DC 0-5V|
|DC 0-20mA|4|6|DC 2-10V|
|DC 0-5V|5|7|DC 4-20mA|
|DC 2-10V|6|8|Transmitter Power Supply|
|DC 4-20mA|7|
|Triac|8|
**----- End of picture text -----**<br>
_West Instruments is a division of Danaher (UK Industries) Ltd. A member of the Danaher Corporation. Registered in England No 2815444 VAT No GB788620583 Registered Office: Danaher House, Parkway One Business Centre, Parkway Drive, Sheffield, S9 4WU_
CD eanauen..... HENGSTLER —
Updated at April 29, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →