Image not available
Illustrative purposes only
P2-4816
ELECTROMECHANICAL TOTALIZING COUNTER
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: REDINGTON COUNTERS
- Product type:
- No; ELECTROMECHANICAL TOTALIZING COUNTER; No. of Digits / Alpha:6; Digit Height:4.3mm; Supply Voltage Min:-; Supply Voltage Max:115VAC; Panel Cutout Height:26.67mm; Panel Cutout Widt
- SVHC: No SVHC (15-Jan-2018)
- Digit Height: 4.3mm
- Product Range: -
- Panel Cutout Width: 43.69mm
- Supply Voltage Max: 115VAC
- Supply Voltage Min: -
- Panel Cutout Height: 26.67mm
- No. of Digits / Alpha: 6
- Operating Temperature Max: 60°C
- Operating Temperature Min: -26°C
| Delivery and price | |
|---|---|
| Units per pack | 25 |
| Price | 33.22 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **ABOUT REDINGTON**
Since 1961 REDINGTON has offered products that have proven to be rugged and manufactured to the highest quality standards. Over several decades we have focused on bringing our customers quality products at competitive prices. This catalog contains several new and innovative products confirming our commitment to provide state-of-the-art solutions for our customers.
Over the past few years, we have committed to developing the capabilities to provide the finest electronic solutions for our customers’ counting, elapsed time indicating and controlling needs. We have done this while continuing to supply and support our broad range of rugged mechanical and electromechanical products. We stand ready to work with our customers to provide cost effective solutions and to match the best technology with your applications.
## **CUSTOMER SERVICE**
We are committed to providing the best customer service anywhere. We strive to provide our customers with prompt replies, on time delivery and hassle free customer satisfaction. Our goals are to serve our customers and take the extra steps necessary to satisfy your requirements.
We provide field assistance backed up by competent technical support from our headquarters location. We have Authorized Distributors and Representatives throughout North America that stand ready to assist our customers. Contact your local Sales Representative, or call us at the factory, to get the name of your nearest authorized distributor.
||**How to Contact Us**|**How to Contact Us**||
|---|---|---|---|
|||**REDINGTON COUNTERS, INC.**|**REDINGTON COUNTERS, INC.**|
|**on the web...**||**P.O. Box 608**||
||Sap|**130 Addison Road**|**130 Addison Road**|
|**web site: www.redingtoncounters.com**<br>**e-mail: info@redingtoncounters.com**||**Windsor, CT 06095**|**Windsor, CT 06095**<br>**by Mail...**|
||**Customer Service/Application Assistance**|||
|**by Phone...**|**(800) 395-7337**|**by Fax...**|**Fax: (860) 688-1591**|
||**(860) 688-6205**|||
**www.redingtoncounters.com**
**Table of Contents**
## **Introduction**
Page# 4
## **COUNTERS**
## **Electronic**
||**Model 33**|LCD 8 digits, self powered|8|
|---|---|---|---|
|**_NEW!_**|**Model 3302**<br>**Model 52**|LCD Large 4 digit display PCB Mount, self powered<br>LCD 8 digits, uni or bi-directional|10<br>11|
||**Model 53**|LCD 7 or 8 digits, self powered, AC, DC or switch input|13|
||**Model 54**|LCD 7 or 8 digits, PCB module, self-powered|15|
||**Model 55**|7 digits, 3 mountings, AC/DC, EEPROM, reset|52|
||**Model 56**|7 digits, 3 mountings, AC/DC, EEPROM, reset, “Alerts”|55|
||**Model 57**|7 digits, 3 mountings, DC, EEPROM, reset, multi-function, 1 or 2 displays|58|
||**Model 59**|7 digits, PCB mount, DC, EEPROM, reset, multi-function|61|
||**Model 88**|LCD 8 digits, EEPROM, multifunction, uni or bi- directional|85|
||**Model 94**|LCD 6 digits, 3 mountings, reset, large figures|16|
|**Electromechanical**|**Electromechanical**|||
||**Model 10**|General-purpose totalizer, 6 figures, versatile mountings|19|
||**Model 10**|General-purpose totalizer, 7 figures, versatile mountings|20|
||**Model 40**|Low cost, 6 or 7 figures, non-reset|21|
||**Model 44**|6 figures, non-reset|23|
||**Model 48**|Compact 6 or 7 figures, non-reset|24|
||**Model 49**|4 or 6 figures, push-button reset|26|
||**Model 128**|4 figures, rotary reset, panel or base mount|28|
||**Model 300**|6 figures, panel mount, push-button reset|29|
|**Mechanical**|**Mechanical**|||
||**Model 08**|Rotary counter|30|
||**Model 14**|Small, rotary or stroke counter|31|
||**Model 20**|Medium duty, stroke counter|35|
||**Model 22**|Medium duty, rotary counter|36|
||**Model 27**|Heavy-duty, stroke counter, 5 figures|37|
||**Model 28**|Heavy-duty, stroke counter, 5 figures|38|
||**Model 29**|Heavy-duty, stroke counter, 6 figures|39|
||**Model 29**|Heavy-duty, rotary counter, 6 figures|40|
||**Model 41**|Combined register and totalizer, 3 or 4 figures|41|
||**Model 46**|Compact, 5 figure, stroke counter|42|
||**Model 750**|Rugged revolution counter|43|
||**Model PCU**|Stroke counter, 3 or 4 figures|44|
## **Electromechanical**
## **Mechanical**
## **Hand Tally Counters**
||**Model 18**|Hand Tally counters|33|
|---|---|---|---|
|**_NEW!_**|**Model 19**<br>**Model 46T**|Modular Tally counters<br>Compact stroke counter with thumb lever, 5 figures|34<br>42|
||**Model E1**|LCD Hand Tally, 4 digits, self powered|17|
|**_NEW!_**|**Model E2/E3**|LCD ADD and ADD/SUBTRACT 4 digit Hand Tally|18|
|||**PREDETERMINING COUNTERS**||
|**Electronic**|**Electronic**|||
||**Model 83**|LCD 6 digits, 1/16 DIN, preset & batch counter, EEPROM, AC/DC|89|
||**Model 88**|LCD 8 digits, serial communications, EEPROM, AC/DC, analog I/O|85|
|**Electromechanical**|**Electromechanical**|||
||**Model 58**|4 or 6 figures, panel mount, SPDT switch|45|
## **Electronic**
## **Electromechanical**
**www.redingtoncounters.com**
**Table of Contents**
## Page#
## **HOUR METERS**
## **Electronic**
||**Model 33**|6 digits, totally sealed, 4 mounting, AC/DC inputs|46|
|---|---|---|---|
||**Model 51**|6 digits, totally sealed, 3 mountings, AC/DC/Inductive, “Alerts”, Tach.|48|
||**Model 53**|7 digits, LCD, self powered, AC, DC or switch input|50|
||**Model 55**|7 digits, 3 mountings, AC/DC, EEPROM, reset|52|
||**Model 56**|7 digits, 3 mountings, AC/DC, EEPROM, reset, “Alerts”|55|
||**Model 57**|7 digits, 3 mountings, DC, EEPROM, reset, multi-function, 1 or 2 displays|58|
||**Model 59**|7 digits, PCB mount, DC, EEPROM, reset, multi-function|61|
||**Model 88**|6 digits, panel mount, Hrs, Min., Sec., serial communications, EEPROM|87|
||**Model 94**|6 digits, 3 mountings, reset, large figures|63|
|**_NEW!_**|**Model 720**|7 digits, rugged steel housing|64|
|**Electromechanical**||||
||**Model 77**|6 figures, non-reset, panel mount|65|
||**Model 710**|5 figures reset, 6 figure non-reset, AC voltage, 3-Hole mount|66|
||**Model 711/731**|7 figures, non-reset, AC/DC voltages|67|
||**Model 711/731**|7 figures, non-reset, AC/DC voltages, distinctive styling|69|
||**Model 711**|6 or 7 figures, reset or non-reset, AC voltage, rectangular styling|70|
||**Model 720**|5 or 6 figures, rugged steel housing, designed to mil-spec.|71|
|**_NEW!_**<br>**_NEW!_**|**Model 722**<br>**Model 732**|6 figures, totally sealed AC Hour Meter, 115/230VAC, 50/60Hz<br>6 figures, totally sealed DC Hour Meter, 10-80 VDC|72<br>74|
|||**PREDETERMINING TIMERS**||
|**Electronic**||||
||**Model 83**|6 digits, 1/16 DIN, EEPROM, serial communications|94|
||**Model 88**|8 digits, EEPROM, serial communications|85|
|||**CONTROLLERS & INDICATORS**||
|**Electronic**||||
||**Model 53**|Tachometer, 4 digits, LCD, self powered, AC/DC inputs|76|
||**Model 85**|4 digits, 1/8 DIN, RED or Green display, input scaling, EEPROM|78|
||**Model 88**|8 digits, panel mount, serial communications, input scaling, EEPROM|85|
||**Model 92**|Hand Held Tachometer/LCD, rotary and linear speed indicator|98|
|||**DIGITAL PANEL METERS**||
|**Electronic**||||
||**Model 85**|3 1/2 digits, 1/8 DIN, temperature, rate, freq., volts, amps, ohms, modular|78|
|||**ENCODERS/SENSORS**||
||**Model 65**|Incremental optical encoder, uni or bi-directional|100|
||**Model 65**|Proximity switch, DC voltage, for counting or rate input|101|
|||**APPENDICES**||
||Glossary of terms||102|
||Part# Index||106|
**www.redingtoncounters.com**
**Introduction**
## **TOTALIZING COUNTERS**
Totalizing counters are used to sum the total number of cycles or inputs to a device. These counters have no “outputs”. Totalizers can be Mechanical, Electromechanical or Electronic.
Totalizers are typically used to total cycle count, piece count, and linear length or to indicate position. Displays for Mechanical & Electromechanical Totalizers are molded figure wheels usually displaying 0-9 digits on a contrasting background and have a count capacity of 3-8 figures.
## **Basic operation of a mechanical stroke counter**
The illustration below shows the lever in the rest position with a total shaft rotation of X+Y+Z. Although these angles may differ from model to model, the total shaft rotation contains a pre-travel (X), a count stroke (Y), and an over-travel (Z). The lever must start in the pre-travel area and continue through to the over-travel area to register a count. It is recommended that the spring furnished with the counter be used to simplify adjustment of count stroke to drive mechanism.
## **Mechanical Totalizers**
The input for Mechanical Totalizers can be Rotary, Stroke or Rotary Ratchet. Mechanical Totalizers require no operating power or sensor and are easy to install. For hand operated applications you need to consider our Model 18, Model 19 or Model 46 with thumb lever option.
**Note:** This illustrates rotations 2 and 3 only.
## **Typical Applications**
**SHAFT ROTATIONS:** Arrows indicate shaft rotation to increase count.
**==> picture [89 x 18] intentionally omitted <==**
**----- Start of picture text -----**<br>
Left-hand top-coming:<br>(rotation #1)<br>**----- End of picture text -----**<br>
**==> picture [81 x 19] intentionally omitted <==**
**----- Start of picture text -----**<br>
Left-hand top-going:<br>(rotation #2)<br>**----- End of picture text -----**<br>
**==> picture [94 x 18] intentionally omitted <==**
**----- Start of picture text -----**<br>
Right-hand top-coming:<br>(rotation #3)<br>**----- End of picture text -----**<br>
**==> picture [87 x 18] intentionally omitted <==**
**----- Start of picture text -----**<br>
Right-hand top-going:<br>(rotation #4)<br>**----- End of picture text -----**<br>
**==> picture [164 x 345] intentionally omitted <==**
**----- Start of picture text -----**<br>
Punchpress Gaming<br>2<br>[ssssisjs ?<br>Inventory Printing Press<br>Model 20<br>Model 18<br>Model 46<br>**----- End of picture text -----**<br>
**www.redingtoncounters.com**
**4**
**Introduction**
## **Electromechanical Totalizers**
These count on AC or DC voltage input signals. Electromechanical Totalizers are often used when it is desirable to mount the totalizer in a “remote” location. The input can be from a variety of sensors including a Proximity switch, Photoelectric or Mechanical switch. Several choices are available for mounting, reset and add-subtract counting.
**==> picture [90 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
Typical Applications<br>**----- End of picture text -----**<br>
**==> picture [212 x 227] intentionally omitted <==**
**----- Start of picture text -----**<br>
Printing Press Photocopiers Gaming Machines<br>} i La “<br>Model 48<br>Model 40<br>Model 10<br>**----- End of picture text -----**<br>
**==> picture [153 x 82] intentionally omitted <==**
**----- Start of picture text -----**<br>
Model 33 Model 94<br>Model 88 Model 53<br>**----- End of picture text -----**<br>
## **PREDETERMINING COUNTERS/TIMERS**
Predetermining counters can provide the user with an output signal when a preset number is reached. Typical applications are controlling batch or lot size, positioning, punching, converting or cut-to-length.
## **Electromechanical Predetermining Counters**
Electromechanical predetermining counters are easy to preset and apply. They are ideal for slow batch counting and remote locations. They are limited on their count speed and do not have automatic reset capability. The input signal is an AC/DC voltage source and can come from switch or relay contacts, photoelectric control or proximity switch.
## **Typical Applications**
## **Electronic Totalizers**
Electronic Totalizers utilize LED’s or LCD’s as displays with a variety of colors and digits sizes. The count capacity can be up to 8 digits with leading “0” suppression. Electronic Totalizers provide the user with several advantages over Mechanical or Electromechanical Totalizers. Electronic Totalizers are silent, have high- speed count/input capability, interface easily with a variety of sensors, have communications, programmable decimal points, input scaling and quadrature inputs.
**Typical Applications**
**==> picture [180 x 82] intentionally omitted <==**
**----- Start of picture text -----**<br>
Office Equipment Control Panels<br>Cae =<br>ke _Saee)<br>Injection Molding Test Equipment<br>**----- End of picture text -----**<br>
**==> picture [180 x 154] intentionally omitted <==**
**----- Start of picture text -----**<br>
Process Control Batch Control<br>I<br>a<br>Model 58<br>**----- End of picture text -----**<br>
## **Electronic Predetermining Counters/Timers**
They provide an output signal, relay contacts or solid state, when a preset number is reached. They can be used for cut-to length, batch or cycle counting, punching and positioning. They can also interface with most sensors including Encoders, Proximity switches and Photoelectric controls. Some models are available with an analog input and output.
**www.redingtoncounters.com**
**5**
**Introduction**
They feature high speeds, silent operation, instant reset, without loss of incoming counts, bi-directional count capability, data communications, LED or LCD displays, programmable decimal points and input scaling.
## **Typical Applications**
**==> picture [158 x 162] intentionally omitted <==**
**----- Start of picture text -----**<br>
Cut-to-Length Batching<br>ge ae a<br>a<br>Models 83 Models 88<br>**----- End of picture text -----**<br>
## **RATE INDICATORS AND CONTROLLERS**
Rate Indicators and Controllers can be used to monitor or measure frequency or RPM. Hand Held Tachometers are available to measure RPM or Linear speed. Panel mount indicators/controllers can display and control High-Low setpoint limits and provide an output signal for controlling.
## **Typical Applications**
**==> picture [80 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
Flow Level and Control<br>**----- End of picture text -----**<br>
**==> picture [45 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Temperature<br>**----- End of picture text -----**<br>
**==> picture [82 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
Hand-Held Tachometer<br>**----- End of picture text -----**<br>
## **DIGITAL PANEL METERS**
Digital Panel Meters can be used to solve a wide range of applications. These include, Indication or Controlling, Volts, Current, Ohms, Temperature, Frequency and RPM. The Redington Model 85 is modular and the main housing, with modules, can be utilized to solve all of the applications below. The Model 85 has “plug-in” modules, which can be configured to the users needs or specifications. The 1/8 DIN enclosure is rated for IP65 and is available with a RED or GREEN LED display.
**==> picture [166 x 145] intentionally omitted <==**
**----- Start of picture text -----**<br>
Typical Applications<br>Temperature Volts/Amps<br>ee<br>| oven [Of}<br>wat ——-eee<br>Model 88<br>Model 85<br>**----- End of picture text -----**<br>
## **HOUR/MAINTENANCE METERS**
Hour/Maintenance Meters are used to record “running” hours for preventive maintenance or warranty purposes. There are several mounting variations available, 2-Hole rectangular, flush-round, flush rectangular, 3-Hole round and PCB Modules. Other models are available for mounting by a DIN rail kit. A wide range of voltages, AC DC or Inductive, makes the Meters adaptable to almost any application. Most Hour Meters are available with 6-7 figures or digits. “Redi-Alert” maintenance alarms can be programmed into the Electronic meters. When the maintenance is due the display will flash off - on and can provide an electrical output by relay or solid- state circuit. Some Meters can record Hour & Counts in the same model.
## **Electromechanical Hour Meters**
Totally sealed Models are provided for harsh environments that conform to SAE J1378 specifications. Models are available with 6-7 figures on a contrasting background. Manual-reset, remote reset and non-reset models provide a wide choice of options. Most models are agency approved, UL/cUL/CSA recognized and CE compliant. This technology is time tested and has proven to be ultra reliable.
**==> picture [192 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
Model 85 Model 88 Model 92<br>**----- End of picture text -----**<br>
**www.redingtoncounters.com**
**6**
**Introduction**
## **Typical Applications**
**==> picture [181 x 166] intentionally omitted <==**
**----- Start of picture text -----**<br>
Test Equipment Control Panel<br>|<br>© 123459<br>Model 710 Model 711 Model 720<br>**----- End of picture text -----**<br>
## **Electronic Hour Meters (LCD)**
The standard mountings for the industry are available. These products are microprocessor based and can be specifically programmed for an application. Models are available with Redi-Alerts, electrical outputs, tachometers, battery operation, or EEPROM memory. Models are also available with an Hour Meter and Counter in the same meter. Totally sealed models conform to SAE-1378 and NEMA 4X specifications.
## **Typical Applications**
**==> picture [231 x 243] intentionally omitted <==**
**----- Start of picture text -----**<br>
Construction Equipment Generators Medical Equipment<br>Model 33<br>eS e e<br>Model 51<br>ce i<br>ekoe<br>Sa—<br>Model 53 Model 57<br>**----- End of picture text -----**<br>
**www.redingtoncounters.com**
**7**
Lt **Model 33**
**LCD Counter**
**Electronic**
## **Description**
The Redington Model 33 line of LCD counters provides a large display, 7mm high figures, in an eight digit counter. The counters are available in a variety of mountings: 2-hole rectangular, 3-hole round, flush-round and flush-rectangular. Voltage operating ranges are 10277 VDC AND 20-277VAC. All models are totally sealed from moisture and dirt and conform to NEMA 4 & 4X specifications when mounted with the optional gasket. Their rugged construction makes them ideal replacements for current electromechanical counters. Units have polarized LCD for high visibility in sunlight.
## **Features Options**
- AC or DC voltage input in the same unit • Custom logos and bezels
- • Totally sealed from moisture and dirt • Terminations • Always on display • Remote reset - dry contact with 6” wire leads • Compact depth • Gaskets • Clip retainer mount or screws (supplied) 5003-002S gasket for 2-hole mount 5003-003S gasket for flush-rectangular mount 5003-004S gasket for flush-round mount 5003-005S gasket for 3-hole round mount
## **Specifications**
**Display:** LCD with large 0.28” [7mm] high figures, **Humidity:** 95% SAE J1378 black on light background **Operating Temperature:** -40°F to +185°F [-40°C to +85°C] **Records & Displays:** 8 digit (99999999) **Sealing:** Totally sealed, panel gaskets-NEMA 4 & 4X **Inputs:** 10 to 277VDC AND 20-277VAC **Agency Approvals:** CE compliant Vih* 20VAC or 10VDC minimum UL/cUL recognized (file# ELIY2.E36690) Vil* 3VAC or 3VDC maximum **Termination:** 0.250” [6.4mm] spades **Speed:** 25 counts per second **Reset:** Optional - dry contact with 6” wire leads **Battery Life:** 7+ years **Case Material:** Polymer (black) **Shock:** 44 to 55g’s, SAE J1378 **Weight:** 1oz [28g] **Vibration:** 20 g @ 10 to 80 Hz, SAE J1378
* Vih is the input high voltage. This is specified as the minimum input voltage that the Model 33 will recognize as a high level. Vil is the input low voltage. This is specified as the maximum input voltage that the Model 33 will recognize as a low level.
Note: When interfacing the Model 33 with a Solid State Relay or AC Sensor, the leakage current needs to be considered. Contact the factory or see the application note at www.redingtoncounters.com for further information.
|**Models**|**Description**||**Models**|**Description**|**Description**|
|---|---|---|---|---|---|
|**3301-0000**|2-Hole Rect.,|10-277 VDC AND 20-277VAC|**3301-0010**|2-Hole Rect.,|10-277 VDC AND 20-277VAC, remote reset|
|**3301-1000**|3-Hole Round,|10-277 VDC AND 20-277VAC|**3301-1010**|3-Hole Round,|10-277 VDC AND 20-277VAC, remote reset|
|**3301-2000**|Flush-Rect.,|10-277 VDC AND 20-277VAC|**3301-2010**|Flush-Rect.,|10-277 VDC AND 20-277VAC, remote reset|
|**3301-3000**|Flush-Round,|10-277 VDC AND 20-277VAC|**3301-3010**|Flush-Round,|10-277 VDC AND 20-277VAC, remote reset|
* All Items are normally in factory stock.
**www.redingtoncounters.com**
**8**
**LCD Counter**
am **Model 33**
**Electronic**
## **Dimensions**
**==> picture [240 x 174] intentionally omitted <==**
**----- Start of picture text -----**<br>
2-Hole<br>2.04 [51.9]<br>0.44 [11.2]<br>1.75 [44.4]<br>0.34 [8.7]<br>——He,<br>1.10 [27.9] 0.89 [22.6] 0.93 [23.5]<br>0.28 [7.0]<br>Ø.15 [Ø3.8]<br>1.41 [35.8]<br>0.06 [1.5]<br>|<br>0.06 [1.5]<br>0.25 [6.3]<br>iz<br>0.99 [25.1]<br>1.43 [36.2]<br>—|<br>**----- End of picture text -----**<br>
In-front panel cutout: 1.45 X 0.95 [24.0 x 37.0] Behind panel cutout: 1.42 X 0.90 [22.9 x 36.1]
**==> picture [218 x 189] intentionally omitted <==**
**----- Start of picture text -----**<br>
3-Hole Round<br>0.44 [11.2]<br>0.34 [8.7]<br>: Ja !<br>Ø2.86 [72.6] 0.93 [23.5]<br>0.28 [7.0]<br>0.12 [3.0]<br>3X Ø.13 [Ø3.2] EQUALLY SPACED<br>ON A 2.53[89.7] B.C.<br>ar<br>0.25 [6.3]<br>0.99 [25.1]<br>fa 1.43 [36.2]<br>Panel cutout: 1.45 X 0.95 [24.0 x 37.0]<br>**----- End of picture text -----**<br>
## **Flush-Round**
## **Flush-Rectangular**
**==> picture [222 x 162] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.44 [11.2]<br>0.34 [8.7]<br>NN ']<br>(an) | BR<br>Ø2.27 [57.7] 0.93 [23.5]<br>0.28 [7.0] os a<br>0.12 [3.0]<br>0.25 [6.3]<br>0.99 [25.1]<br>1.43 [36.2]<br>**----- End of picture text -----**<br>
**==> picture [218 x 145] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.44 [11.2]<br>1.60 [40.6]<br>0.34 [8.7]<br>1.10 [27.9] mae<br>0.89 [22.6] 0.93 [23.5]<br>0.28 [7.0] fmm) [st<br>1.41 [35.8]<br>0.06 [1.5]<br>0.06 [1.5]<br>0.25 [6.3]<br>0.99 [25.1]<br>1.43 [36.2]<br>**----- End of picture text -----**<br>
Panel cutout: 1.45 X 0.95 [24.0 x 37.0] Maximum panel thickness: 0.15 [3.8]
Panel cutout: 1.45 X 0.95 [24.0 x 37.0] Maximum panel thickness: 0.15 [3.8]
## **Applications**
**==> picture [212 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Medical Devices Control Panels<br>**----- End of picture text -----**<br>
**==> picture [75 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Secondary Equipment<br>**----- End of picture text -----**<br>
**==> picture [53 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Test Equipment<br>**----- End of picture text -----**<br>
**==> picture [75 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Production Equipment<br>**----- End of picture text -----**<br>
**==> picture [58 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
Office Equipment<br>**----- End of picture text -----**<br>
**www.redingtoncounters.com**
**9**
am **Model 3302**
**PCB Mount Counter**
**Electronic**
Front Back
## **Description**
The Redington Model 3302-4322 LCD counter provides a very economical, large 4-digit display, 0.75" [19mm] with a PCB mount. The counter is designed to accept dry contact or other solid-state switch-mode inputs. It has remote reset capability that is compatible with dry contact or switch-mode inputs. The maximum pulse frequency is up to 30Hz. The counter is battery operated with a rated life of 5 years.
## **Features**
- Large LCD display
## **Options**
- Non-reset
- Always on display
- Contact closure input & remote reset
- PCB mount
## **Specifications**
**Display:** Large 0.75" [19mm], LCD, black on light background **Displays:** 4 digit (9999) **Inputs:** Dry contact closure or solid-state switch-mode input **Remote Reset:** Dry contact closure or solid-state switch-mode input **Battery Life:** 5 years (with 50% input duty cycle)
**Temp. Range:** -40°F to 185°F [-40°C to 85°C] **Agency Approvals:** CE Compliant **Termination:** (6) 0.025 [0.64] square pins **Weight:** 0.5oz, [14g]
## **Model Description**
3302-4322 4-digit, LCD, 0.75" [19] PCB mount, dry contact closure input and remote reset
## **Dimensions**
**==> picture [480 x 167] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.08 [2.1]<br>0.99 [25.1] 0.10 [2.4]<br>2X 0.20 [5.1] 0.03 [.7] 0.06 [1.6] 2.04 [51.8]<br>0.06 [1.5]<br>0.17 [4.3]<br>Bin if =| |<br>0.81 [20.6] | fay \ 0.75 [19.0] iL 1.13 [28.8]<br>0.63 [16.0]<br>0.10 [2.5]<br>0.06 [1.5]<br>1.31 [33.3] 0.44 [11.2]<br>0.35 [9.0] = ‘ 0.65 [16.4] _ | |<br>Rear View Side View Front View<br>lications<br>Panel Builders Test Equipment Medical Devices Events or People Counter Office Equipment<br>**----- End of picture text -----**<br>
## **Applications**
**www.redingtoncounters.com**
**10**
| | **Model 52**
**LCD Totalizer**
**Electronic**
## **Description**
The Model 52 LCD 8-digit Miniature Electronic Counter offers a low cost general purpose miniature totalizer with a 10 year internal lithium battery. It is an economical replacement for electromechanical counters and is available for bi-directional or quadrature inputs. Front panel reset button can be enabled or disabled by a wiring connection or external contact closure. Easy snap in mount fits 0.94’’ x 1.89’’ [24 x 48mm] DIN panel cutout (0.98’’ x 1.97’’ [25 x 50mm] with adaptor).
## **Features**
- Contact closure/open collector low speed count input with integral de-bounce circuitry (5200-0000)
- Quad signal compatible using 5211-0000 plug-in adaptor. This permits add/subtract counting in synchronization with forward/reverse motion without count loss or gaining additional counts. (5210-0000).
## **Options**
- Optional triggering from any voltage between 5 and 240VAC or VDC using the 5202-0000 adaptor and the Model 5200-0000.
- Choice of mounting available, front panel with supplied bezel or rear mounting clip.
- Front panel meets NEMA4/IP65 specification for indoor use.
- Counting up to 10kHz.
- 7mm black characters, on a light background, LCD display.
## **Specifications**
|**Specificationspecificationsecifications**||||
|---|---|---|---|
|**Power:**|Internal lithium battery. Nominal life 10 years|**Low Speed Count Input:**|(Model 5200-0000) (PIN4) contact|
|**Display:**|8 digit black LCD, 0.3” [7.6mm]||closure/open collector with integral de-|
||characters with leading zero blanking||bounce circuitry. 30Hz maximum,|
|**Manual Reset Enable:**|(PIN 2) link to COMMON (PIN 1) to||negative edge triggered, 0.7V|
||enable front panel reset button||threshold, 15 mS minimum closure time|
|**Count Range:**|99,999,999 display rollover to zero,|**High Speed Count Input:**|(Model 5210-0000) (PIN 5) electronic|
||leading zeros suppressed||input 10kHz maximum, negative edge|
|**External Reset**:|(PIN 3) contact closure/open collector,||triggered, 0.7 threshold 50µS minimum|
||negative edge triggered. 0.7 threshold.||pulse length, TTL/CMOS compatible|
||15mS minimum closure time|**Operating Temperature:**|+14°F to +140°F [-10°C to +60°C]|
|**Direction Input:**|(Model 5210-0000) (PIN 4) connection|**Storage Temperature:**|-4°F to +140°F [-20°C to +60°C]|
||or electronic input TTL/CMOS|**Environmental Protection:**|Front panel is NEMA4/IP65 using|
||compatible. Add= no connection or >||gasket supplied.|
||2.4 volts (logic 1) ; subtract = connect|**Mounting:**|Either with clip mount or two front|
||to COMMON or, 0.7V (logic 0)||screws with bezel supplied.|
||direction input must precede count|**Approvals:**|UL Recognized, CE Compliant|
||input by 5µS (minimum) for valid|**Weight:**|2 oz. [57g]|
||operation.|||
**Models Description Models Description 5200-0000** Counter/Unidirectional, count up **5202-0000** High voltage pulse adaptor (for use with 5200-0000 only) **5210-0000** Counter/Bidirectional, (Add/Subtract) **5211-0000** Quadrature adaptor (for use with 5210-0000 only) **5201-0000** Terminal block adaptor
* Items in bold are normally in factory stock.
**www.redingtoncounters.com**
**11**
| | **Model 52**
**LCD Totalizer**
**Electronic**
## **Accessory Descriptions**
## **5201-0000 SCREW TERMINAL ADAPTOR**
The 5201-0000 adaptor provides screw terminal connections for conductors up to 0.098in² [2.5mm[2] ]. The adaptor snaps on to the rear of the counter. The terminals are protected to the touch and are easily accessible.
## **5202-0000 HIGH VOLTAGE ADAPTOR**
This is a plug in adaptor for use with the 5200-0000. This input adaptor module permits the use of high voltage input pulses from 5-240VAC or VDC. Opto-isolation provides input to output isolation of 5000V. The adaptor plugs into the rear of the counter by integral clips. Connection is by screw terminal for conductors up to 0.098in² [2.5mm[2] ].
## **5211-0000 QUAD ADAPTOR**
This is a plug-in adaptor for the (5210-0000) add/subtract counter. It converts the signal from a quadrature output sensor such as a shaft encoder into count and direction signals. The adaptor retains direct access to the external reset on the 5210-0000. Connection by screw terminals for conductors up to 0.098in² [2.5mm[2] ].
## **Dimensions**
## **Panel Cutout**
**Model 5200-0000**
1.87’’ x 0.87’’ [47.5 x 22.1] +0.02 - 0.0, )1.97’’ X 0.98’’ [50.0 x 24.9] with panel adaptor.)
**==> picture [498 x 397] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.36 [60.0] 0.12 [3.0] with panel adaptor.)<br>re =r<br>1.77 [44.9]<br>1.97 [50.0] Maximum Panel Thickness<br>1.50 [38.0] 0.94 [24.0] 0.3’’ [7.5mm]<br>0.86 [21.9]<br>Er 1.89 [48.0] | 1.20 [30.5]<br>0.16 [4.0] uc<br>Model 5210-0000<br>CONNECTION DETAILS COMMON<br>T + RESET ENABLE 1. BLACK<br>2. GREEN<br>EXTERNAL RESET<br>SLOW SPEED COUNT INPUT 3. YELLOW 2.36 [60.0] 0.12 [3.0]<br>4. BROWN<br>HIGH SPEED COUNT INPUT 5. BLUE 1.77 [44.9]<br>—————— — 1.97 [50.0] il<br>T — Li) | _ |<br>1.50 [38.0] 0.94 [24.0]<br>High Voltage Adaptor [=H 0.86 [21.9]<br>1.89 [48.0] 1.20 [30.5]<br>58.5K bi-directional 0.16 [4.0] x —<br>opto-isotator<br>48-240V 4K7 CONNECTION DETAILS COMMON 1. BLACK<br>aon input _ to counter oT oO EXTERNAL RESETRESET ENABLE 2. GREEN<br>5-48Vinput DIRECTION 3. YELLOW4. BROWN<br>COUNT INPUT 5. BLUE<br>[ r ea Counts inputs circuit configuration t e q - _ =<br>connections to<br>rear screw terminals<br>SIGNAL COMMON<br>48-240V 6 1 2<br>| RESET<br>5-48V 5 2 ENABLE EXTERNALRESET<br>4 3<br>= count inputs<br>High Voltage Adaptor Quadrature Terminal Block<br>Applications<br>**----- End of picture text -----**<br>
Flow Meter
**==> picture [38 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Positioning<br>**----- End of picture text -----**<br>
**==> picture [30 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
Rotation<br>**----- End of picture text -----**<br>
**www.redingtoncounters.com**
**12**
**Model 53**
**LCD Totalizer**
**Electronic**
## **Description**
The Model 53 Electronic Totalizer with 7 or 8 LCD digits is ideal as a replacement for electromechanical totalizers or where external power is not available. Powered by an internal lithium battery these products are highly reliable and provide the user with a choice of several options; with or without reset and multiple count ranges for optimized performance. The case is available in either tan or black.
## **Features**
- Lithium battery
- Choice of non-reset or remote reset
- Switch (no-voltage), 3-30VDC, 20-250VAC/VDC
## **Specifications**
**Figures:** 7 or 8 LCD figures, 0.32’’ [8mm] high **Reset:** Remote, manual, and non-reset **Speed: 7 Digit:** 0-40 counts/second [min. 12.5ms - on, 12.5ms - off] 0-150 counts/second [min. 3.3ms - on, 3.3ms - off] **8 Digit:** 0-35 count/second [min14.3ms - on, 14.3ms - off] **Inputs:** Switch (no-voltage), 3-30VDC, 20-250VAC/VDC Vih 20VAC/3VDC minimum Vil 3VAC/1VDC maximum **Power:** Self-powered (internal lithium battery) **Mounting:** Panel with clip **Terminations:** Terminal block, or connector with 8’’ [200mm] wire leads **Battery Life:** ~20years
## **Options**
- Case color
- **•** Mounting adapter plates
- 8 digits
- • 5003-001S - gasket • Low AC voltage (4-30 VAC)
**Weight** 2 oz. [57g] **Temperature:**
**Operating:** -4°F to +140°F [-20°C to +60°C] **Storage:** -40°F to +165°F [-40°C to +75°C] **Humidity:** 0 to 95% RH, non-condensing **Vibration Operating:** 10 to 55Hz, 0.01” [0.25mm] double amplitude **Non-Operating:** 10 to 55Hz, 0.03” [0.75mm] double amplitude
**Shock Operating:** 10G **Non-Operating:** 30G **Dielectric:** 1000VAC 50/60Hz for 1 minute **Accuracy:** 100% [Provided Signal Meets Stated Parameters] **Approvals:** UL Recognized, CSA Certified, CE Compliant
Note: When interfacing the Model 53 with a Solid State Relay or AC Sensor, the leakage current needs to be considered. Contact the factory or see the application note at www.redingtoncounters.com for further information.
**Models**
**==> picture [471 x 147] intentionally omitted <==**
**----- Start of picture text -----**<br>
Models Reset Input Speed/cps Terminations Color<br>remote none manual switch 3-30VDC 20-250VAC/VDC 40/150 40 term. block 8” wire leads Tan Black<br>5300-0000 X X X X X<br>5300-0001 X X X X X<br>5300-0100 X X X X X X<br>5300-0101 X X X X X X<br>5300-1000 X X X X X<br>5300-1001 X X X X X<br>5300-1100 X X X X X X<br>5300-1010 X X X X X<br>PHT 5300-1011 X X X PTTL X X<br>5300-2000 X X X X X<br>5300-2001 X X X X X<br>5300-2100 X X X X X X<br>5300-2200 X X X X X<br>5300-2201 X X X X X<br>**----- End of picture text -----**<br>
- Items in bold are normally in factory stock.
All part numbers shown are for 7 digit models. Please contact the factory for information on 8 digit models.
## **Dimensions**
**==> picture [459 x 64] intentionally omitted <==**
**----- Start of picture text -----**<br>
TERMINAL BLOCK WIRE LEADS<br>1.58 [40.0]<br>1.72 [43.7]<br>1.92 [48.8] 1.92 [48.8]<br>0.10 [2.5] 1.47 [37.3] 0.10 [2.5] 1.47 [37.3]<br>1.02 [25.9] 0.86 [21.8] 1.02 [25.9] 0.86 [21.8]<br>**----- End of picture text -----**<br>
**www.redingtoncounters.com**
**13**
| | **Model 53**
**LCD Totalizer**
**Electronic**
## **Operating Instructions**
## **MOUNTING:**
**==> picture [210 x 98] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.79 +/- 0.01<br> [45.5 +1/-0]<br>0.89 +/- 0.01 Panel Cutout<br> [22.6 +1/-0]<br>me<br>=<br>The mounting clip accommodates panel thicknesses up to 1/4”<br>[6.4mm].<br>**----- End of picture text -----**<br>
**==> picture [472 x 254] intentionally omitted <==**
**----- Start of picture text -----**<br>
Optional<br>Unit<br>Gasket Panel Clip The mounting clip accommodates panel thicknesses up to 1/4”<br>[6.4mm].<br>WIRING:<br>Panel adapter plates are available in flush and 2 hole mount to fit<br>SWITCH (non-voltage) various panel cutouts. Consult the factory for availability.<br>1 2 3 4 5<br>INPUT RESET<br>md,<br>Color code for the 8” [203mm] lead wires (24AWG) are:<br>Pin 1 used for 0 - 150 cps only 1 - Yellow<br>2 - Blue<br>3 - 30 VDC 3 - Black<br>4 - Violet<br>1 2 3 4 5 5 - Gray<br>INPUT +DC +DC RESET<br>Pin 1 used for 0 - 150 cps only Terminal block will accept wire sizes from 14 to 24AWG.<br>20 - 250VAC/VDC 3 - 30VDC units are protected for transient voltages up to 50 volts<br>with pulse widths of up to 1 second at a 1% duty cycle (including<br>1 2 3 4 5 reverse polarity).<br>INPUT AC/DC AC/DC RESET The operating AC frequency range is 40 to 400Hertz.<br>Pin 1 not used<br>**----- End of picture text -----**<br>
Panel adapter plates are available in flush and 2 hole mount to fit various panel cutouts. Consult the factory for availability.
## **NOTES:**
## **INPUT / RESET PARAMETERS**
- To insure proper performance from totalizers the following minimum input durations are required: 0 to 35 cps totalizer Minimum 14.3 ms “on” 14.3 ms “off” The count is activated on the falling edge. 0 to 40 cps totalizer Minimum 12.5 ms “on” 12.5 ms “off” The count is activated on the falling edge. 0 to 150 cps totalizer Minimum 3.3 ms “on” 3.3 ms “off” The count is activated on the rising edge.
- All resettable totalizers can be reset by a pulse with a minimum duration of 6 milliseconds.
## **DUAL RANGE TOTALIZER PROTECTION FEATURE:**
Dual range totalizers have a built-in range protection feature. This feature will protect the totalizer from receiving a false signal from the unused input line. Once a totalizer has received an input from pin #1 or pin #2, it will only accept inputs from that pin until the unit has been reset. For example, if a totalizer is run in the low speed range and it is determined that a high speed range is preferred, simply switch the input from pin #2 to pin #1 and reset the totalizer to de-activate this range protection feature. Conversely, if a totalizer is run in high speed range and it is determined that a low speed range is preferred, simply switch the input from pin #1 to pin #2 and reset the totalizer.
## **SPECIAL WIRING OPTION**
There is an internal connection between pin 3 and pin 5, a single wire can be used by connecting it to either pin 3 or pin 5. This option **does not** apply for units with input of 20 - 250VAC/VDC or manual reset enable.
## **OPTIONAL INPUTS:**
Optional control circuity (such as transistors) may be used as inputs provided that such circuitry provides the required parameters of the model used.
## **Applications**
Number of Parts Shear Packaging Line
**www.redingtoncounters.com**
**14**
Ht **Model 54**
**Electronic**
**PCB Mount Totalizer**
## **Description**
The Model 54 is a 7 or 8 digit LCD Totalizer with PCB mounting. Ideal for applications where PCB mounting, high reliability and long life are important. Units are 7 or 8 digits and come with their own lithium battery. Totalizers have two count speed ranges, 40cps or 150cps and are customer selectable.
- **Options**
- • Remote or non-reset • Hour Meter • Selectable count speeds • Tachometer • High reliability • Without battery • PCB mounting • 8 digits • Long life lithium battery
## **Features**
- Dry contact closure or voltage pulse input
## **Specifications**
|**Figures:**|||7 LCD , 0.315" (8mm)|**Power:**|Lithium battery (rated @ ~ 20 years)|
|---|---|---|---|---|---|
|**Reset:**|||Remote and non-reset|**Mounting:**|PCB: 0.45" Dia. [11.4mm] Pins, 0 .2" [5.1mm]|
|**Speed:**|**7 Digit:**|**7 Digit:**|0 - 40 counts/second (min. 12.5ms-on, 12.5ms-off)||spacing:|
||||0 - 150 counts/second (min.3.3,s-on, 3.3ms-off)|**Temperature:**||
||**8 Digit:**|**8 Digit:**|0 - 35 counts/second (min. 14.3ms-on,14.3ms-off)|**Operating:**|-4°F to +140°F [-20°C to +60°C]|
|**Inputs:**|||Switch (no-voltage), 3-30VDC, 20-250VAC/VDC|**Storage:**|-40°F to +165°F [-40°C to +75°C]|
||||Vih<br>20VAC/3VDC minimum|**Weight:**|2oz [57g]|
||||Vil<br>3VAC/1VDC maximum|||
|**Models**||**Description**||**Models**|**Description**|
|5400-0010||40/150 cps, switch, remote reset, w/battery||5400-1010|40/150 cps, 3-30VDC, remote reset, w/battery|
* All part numbers shown are for 7 digit models. Please contact the factory for information on 8 digit models.
## **Dimensions**
## **Applications**
**==> picture [399 x 170] intentionally omitted <==**
**----- Start of picture text -----**<br>
5400-0010<br>0.43 [10.9]<br>1.46 [37.1] 1.14 [29.0] Ø.045 [1.14]<br>4X .20 [5.0]<br>0.31 [7.9] 0.17 [4.3]<br>—————— nl<br>0.40 [10.2]<br>0.73 [18.5]<br>aeos» ytPash =F<br>1.65 [41.9]<br>RL 0.30 [7.6]<br>Number of Parts Total Operating Time Motor/Pulley Speed<br>**----- End of picture text -----**<br>
**www.redingtoncounters.com**
**15**
—- **Model 94**
**Electronic**
**LCD Totalizer**
## **Description**
A 6 figure, battery powered, push-button or key reset, electronic counter, available in base mount or panel mount configuration. No external power supply is required. Large 0.50’’ [12mm] LCD figures for fast, easy reading. Operates at 6-240 VAC or VDC. Long lasting internal lithium battery. Attractive styling and silent operation make these models equally well-suited for lab or office equipment applications.
## **Features**
- No external power supply needed
- • Long life lithium battery
## **Options**
- Non-reset
- Remote reset
- Large easy reading display
- Operates at 6 to 240 VAC or VDC
## **Specifications**
**Figures:** 6 LCD figures, 0.50’’ [12mm] high **Mounting:** Base or panel **Reset:** Push-button, or lock and key **Terminations:** (2) #22 AWG 221°F [105° C] wire leads, **Speed:** 0-40 counts/second, (min. 12.5ms - on, 12.5ms - off) 8’’ [203mm] long **Input:** 6-240VAC or VDC **Temp. Range:** -14°F to +122°F [-26°C to +50°C] Vih 6VAC/VDC minimum **Power Source:** Internal lithium battery Vil 2VAC/VDC maximum **Weight:** 18 oz. [510g]
Note: When interfacing the Model 94 with a Solid State Relay or AC Sensor, the leakage current needs to be considered. Contact the factory or see the application note at www.redingtoncounters.com for further information.
**Models Description 9415-001** 6 figure, base mount, push-button reset **9415-003** 6 figure, panel mount, push-button reset **9415-005** 6 figure, panel mount, lock and key reset
- Items in bold are normally in factory stock.
## **Dimensions**
**==> picture [503 x 237] intentionally omitted <==**
**----- Start of picture text -----**<br>
Base Mount Panel Mount<br>3.81 [96.8] 4.44 [112.7]<br>2.97 [75.3]<br>3.15 [80.0] 3.15 [80.0] 2.90 [73.5]<br>ee ee<br>1.65 [41.9]<br>1.36 [34.4] 1.65 [41.9] 1.75 [44.4] 1.50 [38.1] 1.41 [35.8]<br>1.87 [47.6]<br>Eo ce<br>0.88 [22.2] Le ( 3.23 [82.0] 2H) { | 4 ° 4.06 [103.2] a a | _<br>= 3.31 [84.1] -—- —4<br>Mounting holes: 0.14’’ x 0.24’’ [3.6mm x 6.1mm] slots Panel cutout: 3.0’’ x 1.75” [76.2mm x 44.5mm]<br>Mounting holes: 0.17’’ [4.3mm] Dia.<br>Panel Mount/Lock & Key Reset<br>5.50 [139.7]<br>3.15 [80.0] 2.90 [73.5]<br>TePea to<br>1.75 [44.5] fo 1.65 [41.9] T 1.41 [35.8]<br>LI. Jf 2.12 [54.0] ok oa<br>— 5.13 [130.2] —<br>Panel cutout: 4.75 ’’ x 1.50” [76.2mm x 44.5mm]<br>Mounting holes: 0.17’’ [4.3mm] Dia.<br>pplicationslications<br>Office equipment Production Test labs Control panels<br>**----- End of picture text -----**<br>
## **Applicationslications**
**www.redingtoncounters.com**
**16**
| | **Model E1**
**Electronic**
**Tally Counter**
## **Description**
A hand-held reset counter with a 4 digit LCD display and push-button actuator. Case is made of a high impact plastic and comes with a key chain for ease of use. All electronic construction provides a long life counter with no mechanical parts to wear out. The Tally is a handy way to count inventory, attendance, traffic, blood cells, or food portions.
## **Features**
- LCD display
- • Long life
## **Specifications**
**Digits:** 4 LCD’s 0.24’’ [6mm] high (maximum count 9999) **Reset:** Push button
**Battery Operating Life:** 250 days (typical) **Weight:** 0.7 oz [20g] **Color:** Gray body with yellow buttons
**Models Description**
**E1-1804** Electronic Hand Tally
- Item is normally in factory stock.
## **Dimensions**
2.0”L x 1.7”W x 0.7”D [50.8mmL x 43.2mmW x 17.8mmD]
## **Operating Instructions**
1. Press ON/RESET key to power ON the unit.
2. Press STEP key once, the LCD will display ‘1’
3. Press START key, the LCD will display ‘1’
**==> picture [422 x 85] intentionally omitted <==**
**----- Start of picture text -----**<br>
4. Press COUNT key to continue the counting, the LCD will display<br>1<br>from 1 to 2 to 3 to 4 etc.<br>Off ounse yo<br>Anytime you want to restart the count from ‘0’, repeat the above steps. el<br>3<br>Note: If ‘0000’ is displayed, you can press 1 ON/RESET to reset to ‘0’ 2<br>Battery Replacement<br>4<br>**----- End of picture text -----**<br>
When the display gets dim or the counter works erratically, replace the button type battery. Use 1 X G13A or equivalent.
## **Applications**
**==> picture [132 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Inventory Attendance<br>**----- End of picture text -----**<br>
**==> picture [249 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Traffic Food portions Blood cells<br>**----- End of picture text -----**<br>
**www.redingtoncounters.com**
**17**
**Electronic**
**LCD Tally Counter**
am **Model E2 & E3**
## **Description**
Add Model
Add/Subtract Model
The Redington Models E2 & E3 offer an electronic version of the popular Hand Tally counter and are available with a choice of Add only or Add/Subtract models. Counts are input using large positive action buttons. The Add model has a single count button and the Add/Subtract model has two separate count buttons. The “+” button (green) will add a count to the total and the “-” button (red) will subtract a count from the total. When activated, an audible “beeper” sounds every count to verify that a count has been registered. All electronic components provides a long life counter with no moving parts to wear out. The counter is manufactured from impact-resistant plastic, combining lightweight with outstanding durability.
## **Features**
- Add or Add/Subtract models
- Beep at every count with the option of switching the sound off for silent operation
- Cannot accidentally reset or turn off; On/Off/Reset button must be held down for 3 seconds to reset
- Long life battery (replaceable) - typically 250 days without sound
## Large LCD display
•
- No mechanical parts to wear out
- • Large rubber buttons for comfort of use • Ergonomically designed for ease of use • Carrying cord • Light weight
## **Specifications**
**Display:** 4 digit LCD 0.35" [9mm] high **Battery Operating Life:** 250 days (without sound) **Reset:** Push button
**Models Description E2-1804** Electronic Hand Tally (Add only) **E3-1804** Electronic Hand Tally (Add/Subtract)
**Operating Temperature:** +32°F to +122°F [0°C to +50°C] **Weight:** 0.7 oz (20g) **Color:** Black case with blue buttons (Add Only) or green and red buttons (Add/Subtract)
## **Dimensions**
2.4" L x 1.4" W x 0.6" D [60mm x 35mm x 15mm]
* All Items are normally in factory stock.
## **Operating Instructions**
- Press On/Off/Reset button to power ON the unit
- Add model - Press count button to increment count
- Add/Subtract model - Press the “+” button to Add, Press the “-” button to Subtract
## **Battery Replacement**
When the display gets dim, replace the battery. Use 1 type AG10 1.5 V or equivalent Observe polarity (±) during replacement
- To reset counter press the On/Off/Reset button for 3 seconds
- To switch the sound Off/On at any time, hold the count button down for 3 seconds
- To turn Off, press the On/Off/Reset for 3 seconds when counter display is at “0”
## **Applications**
**==> picture [463 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Inventory Attendance Traffic Food portions Blood cells<br>**----- End of picture text -----**<br>
**www.redingtoncounters.com**
**18**
|} **Model 10**
**Electromechanical**
**Totalizer**
## **Description**
A 6 figure general purpose, rugged, electromechanical counter, either panel or base mounted, with manual knob reset, key reset, or non-reset. Frame and housing provides rigid support for accurate alignment and trouble-free use. Distinctive numerals enhance visibility under adverse viewing conditions.
## **Features**
- Panel or base mount
- Rigid support for accurate alignment
- Enhanced visibility
- Manual knob, key or non-reset
## **Options**
- Voltages
- • Lead lengths
- Terminations
- Mounting
- 1071-024S - additional key for model 1026
## **Specifications**
**Figures:** 6 figures, white on black, 0.19’’ [5mm] high **Reset:** Knob, lock and key, or non-reset **Speed:** 1,000 counts/minute (min. 30ms - on, 30ms - off) **Voltage:** 24, 115, 230 VAC or 24 VDC (+/- 10%, but not to exceed 10 volts) **Power:** 7.8 watts (nominal)
**Mounting:** Base or panel **Terminations:** (2)#22 AWG 105°C wire leads, 8’’ [203mm] long **Operating Life:** Beyond 50 million counts **Temp. Range:** -15°F to +140°F [-26°C to +60°C] **Approvals:** UL Recognized, CSA Certified, CE Compliant **Weight:** 18 to 22 oz. [510 to 624g]
## **Models Description**
1-1006 230VAC, base mount, knob reset **2-1006** 115VAC, base mount, knob reset 3-1006 24VAC, base mount, knob reset 8-1006 24VDC, base mount, knob reset 2-1016 115VAC, base mount, non-reset
P1-1006 230VAC, panel mount, knob reset **P2-1006** 115VAC, panel mount, knob reset
## **Models Description**
P3-1006 24VAC, panel mount, knob reset P8-1006 24VDC, panel mount, knob reset P2-1016 115VAC, panel mount, non-reset P31-1026 230VAC, panel mount, lock and key reset **P32-1026** 115VAC, panel mount, lock and key reset P33-1026 24VAC, panel mount, lock and key reset P38-1026 24VDC, panel mount, lock and key reset
* Items in bold are normally in factory stock.
## **Dimensions**
**==> picture [488 x 225] intentionally omitted <==**
**----- Start of picture text -----**<br>
Base Mount Panel Mount<br>3.68 [93.4] 4.45 [113.0]<br>2.81 [71.4]<br>Fr 1 2 3 4 5 6 1 [22.3]0.88 [32.9]1.30 [41.4]1.63 a 1.74 [44.2] O 1 2 3 4 5 6 O|—+ 1.50 [38.1]1.87 [47.5] | i 1.62 [41.1] mi<br>s,s a O o—t | I |<br>3.23 [82.1]<br>——— 3.31 [84.1] - 2.51 [63.8] | 4.06 [103.1] FL 2.27 [57.7]<br>Screws provided: 6-32 x 0.6 [15.2mm]<br>Mounting holes: 0.15’’ [3.8mm] Dia.<br>Panel cutout: 3.85’’ x 1.75’’ [97.8 x 44.5mm]<br>Lock and Key Reset<br>5.55 [140.9]<br>1 2 3 4 5 6 2.12 [53.9] 1.61 [40.9]<br>1.75 [44.5]<br>®| LC) lo} | O . |<br>5.13 [130.3] 2.27 [57.7]<br>Screws provided: 6-32 x 0.6 [15.2mm]<br>Applications Panel cutout: 4.88’’ x 1.75’’ [124.0 x 44.5mm]<br>Molding machines Punch press Printing presses Test labs Secondary Machines<br>**----- End of picture text -----**<br>
**www.redingtoncounters.com**
**19**
| | **Model 10**
**Electromechanical**
**Totalizer**
## **Description**
A 7 figure, rugged, electromechanical counter, either panel or base mounted, with manual knob reset, key reset, or non-reset. Frame and housing provides rigid support for accurate alignment and trouble-free use. Large, easy-to-read numerals assure readability.
## **Features**
- 7 figure
- Panel or base mount
- Rigid support for accurate alignment
- Large easy to read numerals
## **Options**
- Voltages
- Lead lengths
- • Terminations
- Wheel color
## **Specifications**
**Figures:** 7 figures, white on black, 0.19’’ [5mm] high **Reset:** Knob, lock and key, or non-reset **Speed:** 1,000 counts/minute (min. 30ms - on, 30ms - off) **Voltage:** 24, 115, 230 VAC or 24 VDC (+/- 10%, but not to exceed 10 volts) **Power:** 7.8 watts (nominal)
**Models Description** 1-1007 230VAC, base mount, knob reset 2-1007 115VAC, base mount, knob reset 3-1007 24VAC, base mount, knob reset 8-1007 24VDC, base mount, knob reset 2-1017 115VAC, base mount, non-reset
**Mounting:** Base, panel, or behind the panel **Terminations:** (2)#22 AWG 105°C wire leads, 8’’ [203mm] long **Operating Life:** Beyond 50 million counts **Temp. Range:** -15°F to +140°F [-26°C to +60°C] **Approvals:** UL Recognized, CSA Certified, CE Compliant **Weight:** 14 to 18 oz. [397 to 510g]
**Models Description** P2-1007 115VAC, panel mount, knob reset P2-1027 115VAC, panel mount, lock and key reset P8-1027 24VDC, panel mount, lock and key reset
- R2-1007 115VAC, behind the panel, knob reset R2-1017 115VAC, behind the panel, non-reset
## **Dimensions**
**==> picture [475 x 260] intentionally omitted <==**
**----- Start of picture text -----**<br>
Base Mount Panel Mount<br>3.95 [100.3] 4.44 [112.9]<br>2.88 [73.2]<br>1.88 [47.6]<br>1 2 3 4 5 6 7 0.87 [22.2] 1.50 [38.1] 1 2 3 4 5 6 7 1.50 [38.1] 1.50 [38.1]<br>3.31 [84.1]<br>2.51 [63.8] 4.07 [103.3] 2.42 [61.4]<br>— 3.67 [93.3] : ae ; | a<br>Screws provided: 6-32 x 0.6 [15.2mm]<br>Mounting holes: 0.15’’ [3.8mm] Dia.<br>Panel cutout: 3.85’’ x 1.75’’ [97.8 x 44.5mm]<br>Lock and Key Reset<br>5.54 [140.7]<br>2.12 [54.0]<br>1 2 3 4 5 6 7 1.50 [38.1]<br>1.75 [44.5]<br>od 5.13 [130.3] J 2.49 [63.1]<br>Screws provided: 6-32 x 0.6 [15.2mm]<br>Panel cutout: 4.88’’ x 1.75’’ [124.0 x 44.5mm]<br>lications<br>Molding machines Punch press Printing presses Test labs Secondary Machines<br>Y ieee —<br>**----- End of picture text -----**<br>
## **Applications**
**www.redingtoncounters.com**
**20**
| | **Model 40**
**Electromechanical**
**Totalizer**
## **Description**
The Model 40 is a low cost, non-reset totalizer, available with 6-7 figures (white on black background). A wide choice of operating voltages and mountings make this product adaptable for most applications. The Model 40 is an ideal solution for applications that require low cost and product reliability.
## **Features**
- Low cost
- • Small size
- DC and AC
- **Options** • 6 or 7 figure • Multiple mounting choices • Voltages
## **Specifications**
**Figures:** 6 or 7 figures, white on black, 0.12” (3 mm) high **Terminations:** (2)#22 AWG 221°F [105°C] wire leads,10.5” **Reset:** Non-reset [266.7mm] long or (2) 0.03” [0.8mm] Dia. pins for PCB **Speed:** 600 counts/minute (min. 50ms - on, 50ms - off) mounting **Voltage:** 115 VAC, 5, 12 or 24 VDC (+ 10/-15% tolerance) **Operating Life:** Beyond 3 million counts **Power:** 1.4 watts AC, 1.0 watts DC (nominal) **Temp. Range:** +23°F to +104°F [-5°C to +40°C] **Mounting:** Rear, behind the panel, snap-in, base or PCB mount **Weight** : Less than 1 oz. [28g]
|**Models**|**Description**|**Models**|**Description**|
|---|---|---|---|
|2-4016|115VAC, 6 figure, rear mount, wire leads|2-4017|115VAC, 7 figure, rear mount, wire leads|
|R2-4016|115VAC, 6 figure, behind the panel mount, wire leads|R2-4017|115VAC, 7 figure, behind the panel mount, wire leads|
|R9-4016|12VDC, 6 figure, behind the panel mount, wire leads|R9-4017|12VDC, 7 figure, behind the panel mount, wire leads|
|SR2-4016|115VAC, 6 figure, snap-in panel mount, wire leads|SR2-4017|115VAC, 7 figure, snap-in panel mount, wire leads|
|T2-4016|115VAC, 6 figure, PCB mount, pins|T2-4017|115VAC, 7 figure, PCB mount, pins|
|V8-4016|24VDC, 6 figure, V-base mount, wire leads|V8-4017|24VDC, 7 figure, V-base mount, wire leads|
**www.redingtoncounters.com**
**21**
ai **Model 40**
**Totalizer**
## **Electromechanical**
## **Dimensions**
**==> picture [298 x 186] intentionally omitted <==**
**----- Start of picture text -----**<br>
Rear Mount<br>1.17 [29.6]<br>0.20 [5.2]<br>1.18 [30.0] 1.63 [41.5] 0.04 [1.0] 0.59 [15.0]<br>a 0.35 [8.8] cet -<br>0.71 [18.0] 0.69 [17.6]<br>mma)<br>0.08 [2.0]<br>| Behind the Panel Mount Pb A M3 X 0.5 [12.7]<br>2X Ø.10 [Ø2.6] X 0.35 DEEP<br>1.28 [32.4]<br>1.63 [41.5]<br>1.00 [25.4] 0.39 [10.0] 1.17 [29.6]<br>0.44 [11.2] 0.93 [23.7]<br>0.37 [9.4] 0.71 [18.0] 0.69 [17.6]<br>ae<br>1.01 [25.7]<br>eo 1.18 [30.0]<br>**----- End of picture text -----**<br>
**==> picture [474 x 416] intentionally omitted <==**
**----- Start of picture text -----**<br>
Snap-In Panel Mount V-Base Mount<br>1.63 [41.4] 1.77 [45.0]<br>1.13 [28.6] 0.06 [1.6]<br>1.32 [33.5] 0.08 [2.0]<br>0.39 [10.0] 1.56 [39.5]<br>Piet TE Pe 4=1) 2.38 ae<br>0.71 [60.5]<br>1.06 [27.0] [18.0]1.86<br>[47.2]<br>vane<br>PANEL CUTOUT: 1.20 [30.5] X 0.96 [24.4]<br>RECOMMENDED PANEL THICKNESS: 0.04 [1.0] to 0.08 [2.0] 1.18 [30.0] 4X 0.16 [4.0] X<br>D-Base Mount<br>2.24 [57.0]<br>1.83 [46.4] 0.21 [5.3] 1.77 [45.0] 0.06 [1.6]<br>— a Po<br>0.71 [18.0] 0.75 [19.1]<br>gome(7 [1<br>2X 0.14 [3.6] X 0.22 [5.6] SLOT<br>PCB Mount<br>0.39 [10.0] 1.17 [29.6]<br>0.04 [1.0] 0.59 [15]<br>1.18 [30.0] 1.63 [41.5] 0.20 [5.2] 0.30 [7.7]<br>oe<br>0.71 [18.0] 0.50 [12.7] 0.50 [12.7]<br>0.25 [6.4] 0.69 [17.6]<br>ln ee<br>Ø.08 [Ø2.0]<br>M3 X 0.5 [12.7]<br>lications<br>Vending/Gaming machines Photocopi- Items dis- Office equipment<br>EEE | — ers ) pensed fe ee |<br>**----- End of picture text -----**<br>
## **Applications**
**www.redingtoncounters.com**
**22**
4
**Electromechanical**
**Totalizer**
**Model 44**
## **Description**
A 6 figure, non-reset counter. Metal/plastic frame assembly assures ruggedness while one piece cover discourages tampering. Precision molded internal gearing requires no lubrication for long, accurate count life. Applications include warranty verification, electronic game counting, coin box tallies, or wherever small size, highly visible numerals, and solid construction are critical.
**Features**
- Small size
- Highly visible numerals
- Solid construction
## **Specifications**
**Figures:** 6 figures, white on black, 0.18’’ [4.6mm] high **Reset:** None **Speed:** 600 counts/minute
- (min. 50ms - on, 50ms - off)
- **Voltages:** 115VAC, 24VDC **Power:** 1.5 watts (nominal)
- (+/- 10%, but not to exceed 10 volts)
## **Models Description**
- 2-4416 115VAC, 6 figure, rear mount 8-4416 24VDC, 6 figure, rear mount
R2-4416 115VAC, 6 figure, behind the panel mount R8-4416 24VDC, 6 figure, behind the panel mount
## **Options**
- Voltages
- 7 figure
- • Lead length
- Special connectors
- • Extended temperature range • Count x 2
**Mounting:** Rear, behind the panel, base, or combination **Terminations:** (2) #22 AWG 221°F [105°C] wire leads, 10’’ [254mm] long **Operating Life:** Beyond 3 million counts **Temp. Range:** +23°F to +104°F [-5°C to +40°C] **Approvals:** UL Recognized, CE Compliant **Weight:** 2.5 oz. [71g]
## **Models Description**
V2-4416 115VAC, 6 figure, base mount V8-4416 24VDC, 6 figure, base mount
RV2-4416 115VAC, 6 figure, combination mount RV8-4416 24VDC, 6 figure, combination mount
**Dimensions**
## **Rear Mount**
## **Behind the Panel Mount**
**==> picture [463 x 91] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.00 [25.4] 2.18 [55.4]<br>1.36 [34.5] 2.18 [55.4]<br>0.41 [10.4] 1 2 3 4 5 6 0.78 [19.8] 1 2 3 4 5 6 0.83 [21.1] 0.78 [19.8]<br>1.11 [28.2]<br>Seif Fk fe 1.36 [34.5] te<br>Mounting hole: For M3 screw<br>Mounting holes: For M3 self tapping screw<br>Snap-In Panel Mount Base Mount<br>**----- End of picture text -----**<br>
**==> picture [151 x 93] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.48 [37.6]<br>1.38 [35.1] 0.12 [3.1]<br>0.41 [10.4]<br>1.03 [26.2]<br>1 2 3 4 5 6 1.14 [29.0]<br>1.54 [39.1] 0.10 [2.5] — 2.08 [52.8]<br>**----- End of picture text -----**<br>
## **Applications**
**==> picture [73 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Warranty verification<br>**----- End of picture text -----**<br>
**==> picture [250 x 132] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.27 [32.3]<br>1.13 [28.7]<br>0.98 [24.9] 2.38 [60.5]<br>2.00 [50.8]1.75 [44.5] 1 2 3 4 5 6 2.36 [60.0]<br>cal 1.63 [41.4] 2.18 [55.4]<br>Mounting holes: 0.14’’ [3.6mm] Dia.<br>Coin box tallies Electronic game counting<br>**----- End of picture text -----**<br>
**www.redingtoncounters.com**
**23**
am **Model 48**
**Totalizer**
**Electromechanical**
## **Description**
A compact, economical, 6 or 7 figure, non-reset, electromechanical counter designed for general purpose industrial and commercial counting applications. It is designed for a variety of mounting methods as required by the application. Commonly used for coin-operating equipment, photocopiers and vending machines.
|**Features**|**Features**|**Options**||
|---|---|---|---|
|•|6 or 7 figure|•|Voltages|
|•|Compact|•|Lead lengths|
|•|Non-reset|•|5 figure|
|•|Variety of mounting options|||
## **Specifications**
**Figures:** 6 or 7 figures, white on black, 0.17’’ [4.3mm] high **Mounting:** Panel or base **Reset:** None **Terminations:** (2) #22 AWG 105°C wire leads, 12” [305mm] long **Speed:** 1,000 counts/minute AC, (min. 30ms - on, 30ms - off) **Operating Life:** Beyond 10 million counts 1,200 counts/minute DC, (min. 25ms - on, 25ms - off) **Temp. Range:** -15°F to +140°F [-26°C to +60°C] **Power:** AC: 24VAC ~ 4 watts **Approvals:** UL Recognized, CSA Certified, CE Compliant 115VAC ~ 3.5 watts **Weight:** 3.5 oz. [99g] 230VAC ~ 5 watts DC: 12/24VDC ~ 2 watts
|**Models**|**Description**|**Description**|
|---|---|---|
|**P2-4816**|115VAC,|6 figures, P panel mount|
|P8-4816|24VDC,|6 figures, P panel mount|
|R2-4816|115VAC,|6 figures, R panel mount|
|SR2-4816|115VAC,|6 figures, SR panel mount|
|SR8-4816|24VDC,|6 figures, SR panel mount|
|V1-4816|230VAC,|6 figures, V base mount|
|**V2-4816**|115VAC,|6 figures, V base mount|
|V3-4816|24VAC,|6 figures, V base mount|
|V8-4816|24VDC,|6 figures, V base mount|
|V9-4816|12VDC,|6 figures, V base mount|
**Models Description** D8-4817 24VDC, 7 figures, D base mount P2-4817 115VAC, 7 figures, P panel mount P8-4817 24VDC, 7 figures, P panel mount R8-4817 24VDC, 7 figures, R panel mount SR8-4817 24VDC, 7 figures, SR panel mount V2-4817 115VAC, 7 figures, V base mount V8-4817 24VDC, 7 figures, V base mount
* Items in bold are normally in factory stock.
## **Applications**
**==> picture [51 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Control panels<br>**----- End of picture text -----**<br>
Gaming machines
Vending machines
Coin-operated equipment Photocopiers
**www.redingtoncounters.com**
**24**
**Model 48**
**Totalizer**
**Electromechanical**
## **Dimensions**
**==> picture [235 x 130] intentionally omitted <==**
**----- Start of picture text -----**<br>
D - Mount<br>2.20 [55.9] 0.20<br>2.25 [57.2]<br>1.65 [41.9] [5.1]<br>oF ar<br>0.69 12 3 45 6 7 1.01 [25.7]<br>[17.5] .99 [25.1]]<br>1.88 [47.8]<br>Mounting holes: 0.15’’ [3.8] Dia.<br>**----- End of picture text -----**<br>
**==> picture [210 x 139] intentionally omitted <==**
**----- Start of picture text -----**<br>
SR - Mount<br>—_ 1.80 [45.8] : — 2.07 [52.6] |<br>1 2 3 4 5 6 1.44 [36.5]<br>Panel cutout: 1.67’’ x 1.29” [42.4 x 32.8mm]<br>Recommended panel thickness: 0.04” to 0.08” [1.0 to 2.0mm]<br>**----- End of picture text -----**<br>
## **P - Mount**
## **R - Mount**
**==> picture [190 x 62] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.25 [57.2]<br>1.80 [45.7]<br>0.14 [3.6]<br>1.39 [35.3] 1 2 3 4 5 6 1.80 [45.7]<br>**----- End of picture text -----**<br>
Mounting holes: For #5 flat head screw Panel cutout: 1.72’’ x 1.05” [43.7 x 26.7mm]
**==> picture [197 x 126] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.00 [50.8]<br>1.80 [45.7]<br>0.25 [6.3]<br>1.39 [35.3] 1 2 3 4 5 6 1.80 [45.7]<br>Mounting holes: For #5 flat head screw<br>Panel cutout: 1.72’’ x 1.05” [43.7 x 26.7mm]<br>**----- End of picture text -----**<br>
## **V - Mount**
**==> picture [200 x 111] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.25 [57.2]<br>2.36 [60.0]<br>1.86 [47.2] 1 2 3 4 5 6 0.99 [25.1]<br>1.13 [28.6]<br>0.20 [5.0]<br>[4 1.63 [41.4]<br>**----- End of picture text -----**<br>
Mounting holes: 0.16’’ x 0.28’’ [4.1 x 7.1mm] slots
**www.redingtoncounters.com**
**25**
**Model 49**
**Electromechanical**
**Totalizer**
## **Description**
Economically priced 4 and 6 figure push-button reset, electromechanical counter designed for use where limited space is a factor and when reliability is critical. Rugged operating mechanisms require no lubrication or maintenance. Compact size and minimum space requirements make the Model 49 ideally suited for use in control panels, business machines, and test equipment.
|**Features**|**Features**|**Options**||
|---|---|---|---|
|•|Compact|•|Voltages|
|•|No maintenance|•|Extended temperatures|
|•|Quick reset|•|4 or 6 figure|
## **Specifications**
**Figures:** 4 or 6 figures, white on black, 0.16’’ [4mm] high **Mounting:** Panel, base, or bail **Reset:** Push-button **Termination:** (2) #22 AWG 105°C wire leads, 10’’ [254mm] long **Speed:** 600 counts/minute **Operating Life:** Beyond 100 million counts (min. 50ms - on, 50ms - off) **Temp. Range:** -15°F to +140°F [-26°C to +60°C] **Voltages:** 115VAC, 24VDC **Approvals:** UL Recognized, CE Compliant (+10% to - 15%) **Weight:** 4 oz. [113g] (4 fig.), 5 oz. [142g] (6 fig.) **Power:** AC: 115VAC ~ 3 watts DC: 24VDC ~ 2 watts
|**Models**|**Description**|**Description**|**Models**|**Description**|**Description**|
|---|---|---|---|---|---|
|B2-4904|115VAC,|4 figure, bail mount|B2-4906|115VAC,|6 figure, bail mount|
|B8-4904|24VDC,|4 figure, bail mount|B8-4906|24VDC,|6 figure, bail mount|
|**D2-4904**|115VAC,|4 figure, base mount|D2-4906|115VAC,|6 figure, base mount|
|**P2-4904**|115VAC,|4 figure, panel mount|**P2-4906**|115VAC,|6 figure, panel mount|
|**P8-4904**|24VDC,|4 figure, panel mount|**P8-4906**|24VDC,|6 figure, panel mount|
|P9-4904|12VDC,|4 figure, panel mount|P9-4906|12VDC,|6 figure, panel mount|
- Items in bold are normally in factory stock.
**www.redingtoncounters.com**
**26**
| | **Model 49**
**Electromechanical**
**Totalizer**
## **Dimensions**
## **Panel Mount - 4 Figure**
## **Panel Mount - 6 Figure**
**==> picture [485 x 99] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.80 [45.7] 2.55 [64.8] 2.21 [56.1] 2.55 [64.8]<br>Fr<br>= “| r 1 — : — -— 4<br>1.40 [35.6] 1 2 3 4 1.80 [45.7] 0.97 [24.6] 1.40 [35.6] 1 2 3 4 5 6 1.80 [45.7] 0.97 [24.6]<br>Le | ie ee a ie !<br>Panel cutout: 1.46’’ x 1.01” [37.1 x 25.7mm] Panel cutout: 2.00’’ x 1.01” [50.8 x 25.7mm]<br>Mounting holes: For #4 flat head screw Mounting holes: For #4 flat head screw<br>**----- End of picture text -----**<br>
**Bail Mount - 4 Figure**
## **Bail Mount - 6 Figure**
**==> picture [232 x 91] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.65 [41.9] 2.55 [64.8]<br>Torr<br>1 2 3 4 1.14 [28.9] 0.97 [24.6]<br>Panel cutout: 1.46’’ x 1.01” [37.1 x 25.7mm]<br>**----- End of picture text -----**<br>
**==> picture [225 x 83] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.21 [56.1] 2.55 [64.8]<br>1 2 3 4 5 6 1.14 [28.9] 0.97 [24.6]<br>Panel cutout: 2.00’’ x 1.01” [50.8 x 25.7mm]<br>**----- End of picture text -----**<br>
**Base Mount - 4 Figure**
## **Base Mount - 6 Figure**
**==> picture [505 x 151] intentionally omitted <==**
## **Applications**
Test Equipment Control Panels
**www.redingtoncounters.com**
**27**
| | **Model 128**
**Electromechanical**
**Totalizer**
## **Description**
A general purpose, 4 figure electromechanical reset counter perfect for applications where long life, reliability, and accuracy are mandatory. Several mounting alternatives and large, easy-to-read numbers are combined in a rugged housing.
## **Features**
- Rugged housing
- • Long life • Reliable • Accurate
## **Options**
- Voltages
- • Lead lengths • Terminations
## **Specifications**
**Figures:** 4 figures, white on black, 0.19’’ [5mm] high **Mounting:** Base, panel, or behind the panel **Reset:** Knob **Terminations: Speed:** 1,000 counts/minute **Operating Life:** Beyond 50 million counts (min. 30ms - on, 30ms - off) **Temp. Range:** -15°F to +140°F [-26°C to +60°C] **Voltage:** 115 VAC **Approvals:** (+/-10%, but not to exceed 10 volts) **Weight:** 10 oz. [284g] **Power:** 5 watts (nominal) **Models Description Models Description 2-1284** 115VAC, Base mount, knob reset **P2-1284** 115VAC, P panel mount, knob reset D2-1284 115VAC, D panel mount, knob reset **PR2-1284** 115VAC, PR panel mount, knob reset
**Mounting:** Base, panel, or behind the panel **Terminations:** (2)#22 AWG 105°C wire leads, 8’’ [203mm] long **Operating Life:** Beyond 50 million counts **Temp. Range:** -15°F to +140°F [-26°C to +60°C] **Approvals:** UL Recognized, CSA Certified, CE Compliant **Weight:** 10 oz. [284g]
- Items in bold are normally in factory stock.
## **Dimensions**
## **Applications**
**==> picture [59 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
Production totals<br>**----- End of picture text -----**<br>
**==> picture [352 x 196] intentionally omitted <==**
**----- Start of picture text -----**<br>
Base Mount<br>2.30 [58.4]<br>1.81 [46.0]<br>2.49 [63.3]<br>1.71 [43.4]<br>~ ~<br>ee<br>| 7 7 P a<br>1.94 [49.2] 1 2 3 4 1.64 [41.7] 2.25 [57.2]<br>[o_O] |<br>a 1.13 [28.6]<br>Mounting holes: 0.15’’ [3.8mm] Dia.<br>Medical devices Office machines Control Panels<br>**----- End of picture text -----**<br>
**www.redingtoncounters.com**
**28**
| | **Model 300**
**Electromechanical**
**Totalizer**
## **Description**
An extremely long life, 6 figure, electromechanical counter available in panel mounting versions with manual push-button reset. High count speeds, bold numbers, and contemporary design make this ideal in office, graphic arts, medical and computer applications.
- **Options**
- • High count speed • Voltages • Bold numbers • Lead lengths • Contemporary design • Terminations
## **Features**
## **Specifications**
**Figures:** 6 figures, white on black, 0.15’’ [4mm] high **Mounting:** Panel **Reset:** Push-button **Terminations:** Solder terminals **Speed:** 1,000 counts/minute AC, (min. 30ms - on, 30ms - off) **Operating Life:** Beyond 200 million counts 1,500 counts/minute DC, (min. 20ms - on, 20ms - off) **Temp. Range:** -15°F to +140°F [-26°C to +60°C] **Voltages:** 115VAC, 24VDC **Approvals:** UL Recognized, CSA Certified, CE Compliant (+/- 10%, but not to exceed 10 volts) **Weight:** 8 oz. [227g] **Power:** 2.8 watts (nominal) **Models Description Models Description** P2-3106 115VAC, P panel mount, manual reset P9-3206 12VDC, P panel mount, manual reset **R2-3106** 115VAC, R panel mount, manual reset R8-3206 24VDC, R panel mount, manual reset P8-3206 24VDC, P panel mount, manual reset * Items in bold are normally in factory stock.
**==> picture [509 x 183] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions<br>P - Mount R - Mount<br>0.21[5.3]<br>0.13 [3.3]<br>[38.1]1.50 1 2 3 4 5 6 1.98 [50.3] [25.2]0.99 1.50 [38.1] 1 2 3 4 5 6 1.98 [50.3] 0.99 [25.2]<br>— — P<br>2.35 [59.7]<br>2.37 [60.2] 0.13 [3.3] 2.47 [62.7] 2.37 [60.2]<br>ee 2.88 [73.2] os 0.46 [11.7] ie 2.75 [69.9] |<br>Mounting holes: For #8 flat head screw<br>Panel cutout: 2.02’’ x 1.05” [51.3 x 26.7mm]<br>Applications<br>Graphic arts Office equipment Computer applications Medical equipment Control panels<br>**----- End of picture text -----**<br>
**www.redingtoncounters.com**
**29**
am **Model 08**
**Rotary Counter**
**Mechanical**
## **Description**
A 5 figure medium duty counter designed for applications where a rotary counter with a quick reset is desirable. When a 1’ circumference measuring wheel is used with our standard counter, the counter will display feet and inches. Consult the factory if you have custom applications.
## **Features Options**
- Counter will add and subtract
- Double shaft
- • Wheel color • Figure color • Ratios • Mounting • Case color • 98WF - Measuring Wheel - 12” circumference
- Push button reset
- • Versatile mounting
- **1** ,000 revolutions per minute (100 feet per minute)
**Specifications Figures:** 5 figures, 0.20” [5mm] high **Speed:** 1,000 revolutions/minute (100 feet/minute) **Reset:** Push-button **Operation Life:** Beyond 50 million **Rotation:** Top going **Temp. Range:** -15°F to 140°F [-26°C to +60°C] **Shaft Extension:** 0.250“ diameter, left hand or right hand **Weight:** 10 oz. [283g]
**Models Description**
11-0825 Left-hand, top-going, add & subtract
**Models Description**
11-0845 Right-hand, top-going, add & subtract
**Dimensions**
**==> picture [474 x 158] intentionally omitted <==**
**----- Start of picture text -----**<br>
Left - Hand Shaft<br>4.73 [120.1]<br>4.18 [106.0]<br>1.22 [31.0]<br>1.15 [29.2]<br>0.50 [12.7]<br>Ø.25 [6.4]<br>| — +] ot<br>2.53 [64.3] 2.05 [52.1]<br>1.62 [41.1]<br>1.10 [27.9]<br>eq 0.21 [5.3] eS<br>0.42 [10.7] |<br>0.12 [3.0]<br>0.30 [7.5]<br>lications<br>Linear measuring Machine revolutions Positioning<br>**----- End of picture text -----**<br>
**==> picture [54 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
Applications<br>**----- End of picture text -----**<br>
**www.redingtoncounters.com**
**30**
am **Model 14**
**Small Case Totalizers**
## **Mechanical**
## **Description**
The Model 14 is a compact, 5 figure, non-reset totalizer in a molded case with stainless steel shaft. Four types of drives are available and five case configurations. An ideal solution when application requirements call for a low cost and compact totalizer.
## **Features**
- Four types of drives
- Choice of five case configurations
- Built-in non-overthrow mechanism on stroke counters
- Built-in internal stops on stroke counters
## **Options**
- Mounting
- Double shafts
- • Figure background and case colors • Sealed
- 5 Figure: white on black background
## **Specifications**
**Figures:** 5 figures, white on black, 0.16” [4mm] high **Reset:** Non-reset **Rotation:** Top-coming or top-going **Shaft Extension:** Right-hand or left-hand **Shaft Diameter:** 0.125” [3.2mm] **Speed:** Stroke: 1,000 counts/minute Revolution: 3,000 counts/minute Direct: 15,000 counts/minute Rotary Ratchet: 3,000 counts/minute rotary mode 1,500 counts/minute in oscillating mode **Weight:** 0.5 oz. [14g] **Temp:** -40°F to +160°F [-40°C to +71°C] **Operating Torque:** Stroke; 0.8 to 2.0 in/oz **at 75°F** Revolution; 0.15 in/oz Direct; 0.15 in/oz Rotary Ratchet; 0.3 to 1.0 in/oz
**Case Types:** Square base mount Square panel mount Square - no flange Cylindrical base mount Cylindrical panel mount **Drive Types:** Stroke: typical count stroke 39° to 48° typical total stroke 50° to 52° Revolution: adds or subtracts one(1) count per revolution. Direct: adds or subtracts ten (10) counts per revolution Rotary Ratchet: adds ten (10) counts per revolution adds only one (1) count per 36° to 60° oscillation.
|**Models**|**Description**|||**Models**|**Description**|||
|---|---|---|---|---|---|---|---|
|11B-1415|lh, top coming,|stroke,|sq case, base mt|11B-1435|rh, top coming,|stroke,|sq case, base mt|
|11B-1515|lh, top coming,|rev. drive,|sq case, base mt|11B-1535|rh, top coming,|rev. drive,|sq case, base mt|
|11B-1615|lh, top coming,|direct drive, sq case, base mt|direct drive, sq case, base mt|11B-1635|rh, top coming,|direct drive, sq case, base mt|direct drive, sq case, base mt|
|11B-1715|lh, top coming,|rotary rat.,|sq case, base mt|11B-1735|rh, top coming,|rotary rat.,|sq case, base mt|
|11B-1425|lh, top going,|stroke,|sq case, base mt|11B-1445|rh, top going,|stroke,|sq case, base mt|
|11B-1525|lh, top going,|rev. drive,|sq case, base mt|11B-1545|rh, top going,|rev drive,|sq case, base mt|
|11B-1625|lh, top going,|direct drive, sq case, base mt|direct drive, sq case, base mt|11B-1645|rh, top going,|direct drive, sq case, base mt|direct drive, sq case, base mt|
|11B-1725|lh, top going,|rotary rat.,|sq case, base mt|11B-1745|rh, top going,|rotary rat.,|sq case, base mt|
||rat = ratchet|||lh = left hand||sq = square||
||rev = revolution|||rh = right hand||mt = mount||
Similar products are also available in the following configurations: Square case - panel mount change 11B to 11P Square case - without flange change 11B to 11N Cylindrical case - base mount change 11B to 21B Cylindrical case - panel mount change 11B to 21P
**www.redingtoncounters.com**
**31**
|} **Model 14**
**Small Case Totalizers**
**Mechanical**
**Dimensions**
**==> picture [478 x 272] intentionally omitted <==**
**----- Start of picture text -----**<br>
Square Case Base Mount Square Case Without Flange<br>0.88 [22.4] 0.026 [0.7] X 0.026 [0.7] X<br>[10.9]0.43 0.35[8.9] 0.020D [0.5] SLOT 0.81 [20.6] 0.88 [22.4] 0.35 0.020D [0.5] SLOT<br>[8.9] 0.80 [20.3]<br>_— 0.80 H roar ee<br>[26.9]1.06 [20.3] [11.4]0.45 [34.5]1.36 [20.3]0.80 [11.4]0.45 0.40<br>0.125 [3.2] 0.125 [10.2]<br>[3.2]<br>0.03<br>[0.8] 0.43 0.08 [2.0] 0.62 [15.8] 0.03[7.6] 0.43<br>=a 2X 0.13 [3.3] [10.9]0.11 [2.8] | —F- [10.9] i<br>Square Case Panel Mount Cylindrical Case Base Mount<br>[10.9]0.430.88 [22.4] 0.35[8.9] 0.81 [20.6]0.11 [2.8] 0.88 [22.4]0.41 0.35[8.9] 0.84 [21.3][10.4]0.41 0.10<br>Tf. fe [10.9] 4 [2.5]<br>1.36<br>[34.5]<br>1.06 a a<br>[26.9] - 0.80 1.26<br>[11.4]0.45 [20.3]0.80 [20.3]0.38 [32.0]<br>[9.7]<br><-> fli =e 0.125[3.2] c--{ poigg) Fa!) 0.125[3.2] [16.0]0.63<br>0.08[2.0] aPall [15.8]0.62 2x 0.13 [3.3]0.02[0.5] I [10.9]0.43 0.026 [0.7] x 0.020D [0.5] SLOT 0.08[2.0] |ce 0.62 [15.8] Y 2x 0.13 [3.3] 0.020D [0.5] SLOT0.026 [0.7] X Hl<br>**----- End of picture text -----**<br>
## **Cylindrical Case Panel Mount**
0.88 [22.4] 0.35 0.41 [8.9] 0.43 Fa [10.4] [10.9] 1.27 [32.3] 0.38 0.94 [9.7] [23.9] | foo] [= 7 0.125 [3.2] 0.80 [20.3] a ch 0.026 [0.7] X 0.08 [2.0] te 0.62 [15.8] | 0.07 [1.8] l 0.020D [0.5] SLOT it 2X 0.13 [3.3] iH 0.10 [2.5]
**Short Lever (10006-028S)**
## **Standard Lever (10006-027S)**
**==> picture [443 x 141] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.25<br>[6.4] 4+<br>0.31 [7.9]<br>0.129[3.3] 0.22 [5.6] 0.25[6.4] 0.129 0.22 [5.6]<br>[3.3]<br>0.095[2.4] 0.437 [11.1] [16.5]0.65 0.31[7.9] 0.095[2.4] 0.437[11.1] 1.0<br>0.057 [1.5] [25.4]<br>1.12<br>= "yk ¥% | [28.5] 4k 0.057[1.5]<br>Circuit breakers Vending machines Gaming machines Business and office equipment<br>**----- End of picture text -----**<br>
## **Applications**
**www.redingtoncounters.com**
**32**
**Tally Counter**
**Mechanical**
am **Model 18**
## **Description**
A 4 figure, hand-held or desk mounted reset counter with push-button actuator. Case is chrome plated steel. Hand-held model comes with thumb ring for ease of use. Single desk mounted style has plastic base with mounting holes. Multiple desk units, from 2 to 10, mounted on a single base with a common reset. These tallys are a convenient way to count inventory, attendance, traffic, blood cells, or food portions.
## **Features**
- Chrome plated steel housing
- • Long life
## **Options**
- Multiple units
## **Specifications**
**Figures:** 4 figures, white on black, 0.16’’ [4mm] high **Temp. Range:** -15°F to +140°F [-26°C to +60°C] **Reset:** Knob **Weight:** 3.5 oz. [99g] **Operating Life:** Beyond 5 million counts **Models Description Models Description 12-1804** Hand Tally with finger ring 3-1804-6 Versa Tally: 6 units, common reset and base **13-1804** Desk Tally with mouning base 3-1804-7 Versa Tally: 7 units, common reset and base 3-1804-2 Versa Tally: 2 units, common reset and base 3-1804-8 Versa Tally: 8 units, common reset and base 3-1804-3 Versa Tally: 3 units, common reset and base 3-1804-9 Versa Tally: 9 units, common reset and base 3-1804-4 Versa Tally: 4 units, common reset and base 3-1804-10 Versa Tally: 10 units, common reset and base 3-1804-5 Versa Tally: 5 units, common reset and base
* Items in bold are normally in factory stock.
## **Dimensions**
**Model 12-1804**
**==> picture [143 x 114] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.64 [41.7]<br>1.17 [29.7]<br>1 2 3 4<br>2.29 [58.2]<br>/} ol<br>1.81 [46.0]<br>i" ee 1 L y)<br>**----- End of picture text -----**<br>
**==> picture [64 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Model 13-1804<br>**----- End of picture text -----**<br>
**==> picture [118 x 141] intentionally omitted <==**
**----- Start of picture text -----**<br>
3 HOLES 0.138 [3.51] DIA.<br>ON A 1.965 [49.9] B.C.<br>EQUALLY SPACED<br>1 2 3 4<br>1.81 [46]<br>1.17 [29.7]<br>1 2 3 4<br>we —) a<br>2.62 [66.5]<br>e | |<br>Ø 2.24 [57]<br>**----- End of picture text -----**<br>
## **Applications**
**==> picture [439 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Inventory Attendance Traffic Food portions Blood cells<br>**----- End of picture text -----**<br>
**www.redingtoncounters.com**
**33**
**Model 19**
**Modular Tally Counter**
**Mechanical**
## **Description**
The Redington “Victor” counters are manually operated mechanical totalizers ideal for use when you need to count more than one item at the same time. Models are available from a single counter to a maximum of 20 units (4 wide X 5 high). All modules have 4-figure counters and a common rotary reset for the entire row. Each unit can be easily labeled using removable paper tabs. Applications include Lab Counters, Traffic Surveys, Inventory Control, Inspection Tallies, QC Counters, Bus Counters and Point-of-Sale Records.
## **Features**
- Paper tabs for labeling
## **Options**
- Multiple units - up to 20 counters
- Common reset for each row
- Positive action pushbutton
- Lubrication not required
- Quick, simple to operate and accurate
## **Specifications**
**Figures:** 4 figures, white on black, 0.12’’ [3mm] high **Reset:** Knob
**Weight:** ~3.0oz. [85g] per unit
**Models Description Models Description**
11-1904 Modular Tally, single unit 14-1904 21-1904 Modular Tally, 2 units wide x 1 unit high 24-1904 31-1904 Modular Tally, 3 units wide x 1 unit high 34-1904 41-1904 Modular Tally, 4 units wide x 1 unit high 44-1904 12-1904 Modular Tally, 1 unit wide x 2 units high 15-1904 22-1904 Modular Tally, 2 units wide x 2 units high 25-1904 32-1904 Modular Tally, 3 units wide x 2 units high 35-1904 42-1904 Modular Tally, 4 units wide x 2 units high 45-1904 13-1904 Modular Tally, 1 unit wide x 3 units high 23-1904 Modular Tally, 2 units wide x 3 units high 33-1904 Modular Tally, 3 units wide x 3 units high 43-1904 Modular Tally, 4 units wide x 3 units high
Modular Tally, 1 unit wide x 4 units high Modular Tally, 2 units wide x 4 units high Modular Tally, 3 units wide x 4 units high Modular Tally, 4 units wide x 4 units high Modular Tally, 1 unit wide x 5 units high Modular Tally, 2 units wide x 5 units high Modular Tally, 3 units wide x 5 units high Modular Tally, 4 units wide x 5 units high
## **Dimensions**
**==> picture [462 x 107] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dimensions for a single unit are<br>shown to the right. To calculate the 1.6 [40]<br>approximate size of an assembled<br>unit, add 1.5” [37] to the width for 2.9 [74] REF<br>each additional unit in a row, and add<br>2.6” [66] to the depth and 1.5” [37] to 1.7 [43]<br>the height, for each additional row. [| | !<br>2.6 [66]<br>— CH |<br>lications Side View Front View Top View<br>Inventory Attendance Traffic Food portions Blood cells<br>**----- End of picture text -----**<br>
## **Applications**
**www.redingtoncounters.com**
**34**
4 **Model 20**
**Mechanical**
**Stroke Counter**
## **Description**
A highly versatile, 5 figure stroke counter. Numbers are large and distinctive for easy viewing even when above or below eye level. Ruggedly built for years of trouble-free use. An excellent choice for counting parts produced.
- **Options**
- • Durable • Non-reset • Large figures • Large reset knob • Reliable • Right or left-hand shaft extension • 10007-010S - additional lever and spring
## **Features**
**Specifications Figures:** 5 figures, white on black, 0.19’’ [5mm] high **Shaft Extension:** Right-hand or left-hand **Reset:** Knob **Shaft Diameter:** 0.125’’ [3.2mm] **Speed:** 1,000 counts/minute **Operating Life:** Beyond 50 million counts **Rotation:** Top-coming or top-going **Temp. Range:** -15°F to +140°F [-26°C to +60°C] **Count Stroke:** 49° Min. - 60° Max. **Weight:** 5 oz. [142g] **Models Description Models Description** 1-2015 Left-hand, top-coming, standard reset knob **1-2035** Right-hand, top-coming, standard reset knob 1-2025 Left-hand, top-going, standard reset knob 1-2045 Right-hand, top-going, standard reset knob
* Items in bold are normally in factory stock.
## **Dimensions**
## **Right-Hand Shaft**
**==> picture [330 x 103] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.83 [21.1] 1.36 [34.5]<br>Ø.12 [3.2]<br>0.45 [11.6]<br>1.21 [30.6] = 1 2 3 4 5 a +7<br>0.99 [25.2] 1.44 [36.5]<br>——_ ie<br>2.16 [54.9]<br>ic<br>3.21 [81.4]<br>**----- End of picture text -----**<br>
Mounting holes: 0.13’’ x 0.38’’ [3.3 x 9.7mm] slots
## **Applications**
**==> picture [46 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Punch press<br>**----- End of picture text -----**<br>
**==> picture [56 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Machine cycles<br>**----- End of picture text -----**<br>
**==> picture [74 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Secondary machines<br>**----- End of picture text -----**<br>
**www.redingtoncounters.com**
**35**
**Rotary Counter**
**Mechanical**
**Model 22**
## **Description**
A compact, 5 figure, rotary counter, indicating 10 counts/revolution. Design and compact size make it ideally suited for office and test equipment, coin counting and other direct reading instruments.
## **Features**
- Compact size
- • 5 figures
## **Options**
- Large reset knob
- • Special shaft
- Long life
## **Specifications**
**Figures:** 5 figures, white on black, 0.19’’ [5mm] high **Shaft Diamete** r: 0.125’’ [3.2mm] **Reset:** Knob **Ratio:** 10 counts/revolution **Speed:** 1,000 revolutions/minute **Operating Life:** Beyond 50 million counts **Rotation:** Top-coming or top-going **Temp. Range:** -15°F to +140°F [-26°C to +60°C] **Shaft Extension:** Right-hand or left-hand **Weight:** 4 oz. [113g]
**Models Description Models Description** 1-2215 Left-hand, top-coming, add only 7-2225 Left-hand, top-going, add and subtract 1-2225 Left-hand, top-going, add only **7-2235** Right-hand, top-coming, add and subtract 1-2235 Right-hand, top-coming, add only 7-2245 Right-hand, top-going, add and subtract 1-2245 Right-hand, top-going, add only 1-2315 Left-hand, top-coming, add and subtract, non-reset 7-2215 Left-hand, top-coming, add and subtract 1-2325 Left-hand, top-going, add and subtract, non-reset
* Items in bold are normally in factory stock.
## **Dimensions**
**==> picture [414 x 169] intentionally omitted <==**
**----- Start of picture text -----**<br>
Right-Hand Shaft<br>- 3.13 [79.5] a: 1.38 [35.1]<br>I ECD cp | : Ff<br>1.20 [30.5] 1 2 3 4 5 0.99 [25.2] 1.44 [36.5]<br>Ø.12 [Ø3.2]<br>0.83 [21.1]<br>aa 2.16 [54.9] ra 0.47 [12.1] -<br>Mounting holes: 0.13’’ x 0.38’’ [3.3 x 9.7] slots<br>Production equipment Spooling Positioning<br>**----- End of picture text -----**<br>
## **Applications**
**www.redingtoncounters.com**
**36**
|} **Model 27**
**Stroke Counter**
**Mechanical**
## **Description**
A heavy-duty, 5 figure, internal reset, stroke counter. Available in either right-hand or left-hand shaft extension.
## **Features**
## **Options**
- Heavy-duty • Right or left-hand shaft extension
- • Internal reset • 1022-006S - additional spring
## **Specifications**
**Figures:** 5 figures, white on black, 0.31’’ [8mm] high **Shaft Extension:** Right-hand or left-hand **Reset:** Internal - lift cover, reset wheels **Operating Life:** Beyond 200 million counts **Speed:** 750 counts/minute **Temp. Range:** -15°F to +140°F [-26°C to +60°C] **Rotation:** Top-coming **Weight:** 24 oz. [680g] **Count Stroke:** 36° Min. - 45° Max. **Models Description Models Description** 1-2715 Left-hand, top-coming **1-2735** Right-hand, top-coming
* Items in bold are normally in factory stock.
## **Dimensions**
## **Applications**
**==> picture [383 x 229] intentionally omitted <==**
**----- Start of picture text -----**<br>
Right-Hand Shaft<br>2.02 [51.3]<br>2.83 2.28<br>[71.9] 1 2 3 4 5 [57.9] 3.42<br>[86.9]<br>1.14<br>[29.0]<br>4.08 [103.6] 1.05<br>[36.7]<br>4.94 [125.5] 1.75 [44.5]<br>Mounting holes: 0.19’’ [4.8mm] Dia.<br>Punch press Secondary Machines Machine cycles<br>**----- End of picture text -----**<br>
**www.redingtoncounters.com**
**37**
| | **Model 28**
**Stroke Counter**
**Mechanical**
## **Description**
A 5 figure, rugged stroke counter, with right-hand shaft extension, operating lever and attached spring. Rated at 600 counts per minute, this heavyduty model is well suited for most industrial applications.
- **Features** • Heavy-duty • 600 CPM
- **Options** • Lever modifications • 1022-006S - additional spring
- 5 Figures
## **Specifications**
**Figures:** 5 figures, white on black, 0.27’’ [7mm] high **Shaft Extension:** Right-hand **Reset:** Knob, internal, or lock and key **Operating Life:** Beyond 200 million counts **Speed:** 600 counts/minute **Temp. Range:** -15°F to +140°F [-26°C to +60°C] **Rotation:** Top-coming **Weight:** 20 oz. [567g] **Count Stroke:** 36° Min. - 45° Max. **Models Description Models Description** 3-2835 Right-hand, top-coming, internal reset 5-2835 Right-hand, top-coming, lock and key reset **4-2835** Right-hand, top-coming, knob reset * Items in bold are normally in factory stock.
## **Dimensions**
**==> picture [82 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
Right - Hand Shaft<br>**----- End of picture text -----**<br>
**==> picture [283 x 156] intentionally omitted <==**
**----- Start of picture text -----**<br>
| i 4.45 [113.0] [Lb | S 0 OL<br>1 2 3 4 5<br>=+(O 2.83 [71.8]<br>il noooe | Sg ><br>1.55 [39.4]<br>3.19 [80.9] 0.65 [16.4]<br>a 2.13 [54.1] L<br>/— |<br>Mounting holes: 0.18’’ [4.6mm] Dia.<br>**----- End of picture text -----**<br>
## **Applications**
Punch press
Machine cycles
**==> picture [26 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
Shears<br>**----- End of picture text -----**<br>
**www.redingtoncounters.com**
**38**
Ei) **Model 29**
**Stroke Counter**
**Mechanical**
## **Description**
A 6 figure, general purpose heavy duty industrial stroke counter designed for high count rates and continuous operation even under the most adverse operating conditions. Corrosion resistant material and finishes. Large, easy-to-read numbers.
**Options** • Heavy duty • Non-reset • High count rates • Double shaft extensions • Corrosion resistant • Special mounting bases • Weatherized versions • 1022-006S - additional spring • 1255-004S - additional lever
## **Features**
**Specifications Figures:** 6 figures, white on black, 0.30’’ [7.6mm] high **Shaft Extension:** Right-hand or left-hand **Reset:** Knob or lock and key **Shaft Diameter:** 0.25’’ [6.4mm] **Speed:** 1,000 counts/minute **Operating Life:** Beyond 100 million counts **Rotation:** Top-coming or top-going **Temp. Range:** -15°F to +140°F [-26°C to +60°C] **Count Stroke:** 40° Min. - 70° Max. **Weight:** 18 oz. [510g] **Models Description Models Description** 1-2916 Left-hand, top-coming, standard reset knob 1-2946 Right-hand, top-going, standard reset knob 1-2926 Left-hand, top-going, standard reset knob 2-2936 Right-hand, top-coming, lock and key reset **1-2936** Right-hand, top-coming, standard reset knob **V1-2936** Right-hand, top-coming, standard reset knob, V-base
- Items in bold are normally in factory stock.
**Dimensions**
**==> picture [484 x 143] intentionally omitted <==**
**----- Start of picture text -----**<br>
Right - Hand Shaft V - Mount<br>1.97<br>[50.0]<br>5.57 [141.5] 2.15 [54.6]<br>3.91 [99.3] 0.69 [17.5]<br>1.13 [28.6] 1 2 3 4 5 6 7 [:] 1.81 [46.0] 3.25 [82.6] , | | 2.86 [72.6] /<br>=)" —<br>4.38 [111.3] 2.62 [66.5]<br>1.23 [31.1]<br>3.91 [99.3]<br> Mounting holes: 0.22’’ [5.6mm] Dia.<br>**----- End of picture text -----**<br>
## **Applications**
**==> picture [350 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Punch presses Shears Cement trucks<br>**----- End of picture text -----**<br>
**www.redingtoncounters.com**
**39**
**Model 29**
**Rotary Counter**
**Mechanical**
## **Description**
A 6 figure, general purpose, industrial rotary counter designed for use on equipment where environmental conditions are far from ideal. Various count ratios make it suitable for winding equipment, measuring devices and direct reading instruments.
## **Features**
- Heavy duty
- • High count rates • Corrosion resistant
## **Options**
- Non-reset
- • Subtractive • Double shaft extensions • Special mounting bases • Weatherized versions • 98WF - Measuring Wheel - 12” circumference
## **Specifications**
**Figures:** 6 figures, white on black, 0.30’’ [7.6mm] high **Shaft Extension:** Right-hand or left-hand **Reset:** Knob or lock and key **Shaft Diameter:** 0.25’’ [6.4mm] **Speed:** 2,500 counts/minute or revolutions/minute, **Ratio:** 1 count/revolution or 10 counts/revolution whichever is lower **Operating Life:** Beyond 100 million counts **Rotation:** Top-coming or top-going, to add. **Temp. Range:** -15°F to +140°F [-26°C to +60°C] Will not subtract if rotation is reversed **Weight:** 18 oz. [510g] **Models Description Models Description** 11-2916 Left-hand, top-coming, 10 counts/revolution 21-2936 Right-hand, top-coming, 1 count/revolution 11-2936 Right-hand, top-coming, 10 counts/revolution 21-2946 Right-hand, top-going, 1 count/revolution 21-2916 Left-hand, top-coming, 1 count/revolution 22-2936 Right-hand, top-coming, 1 count/revolution, 21-2926 Left-hand, top-going, 1 count/revolution lock & key reset,
## **Dimensions**
**==> picture [365 x 147] intentionally omitted <==**
**----- Start of picture text -----**<br>
Right - Hand Shaft<br>5.57 [141.5]<br>3.91 [99.3] 0.69 [17.5]<br>— ;<br>1.13 [28.6] 1 2 3 4 5 6 1.81 [46.0]<br>(Se nk<br>2.15 [54.6]<br>4.38 [111.1]<br>a | ao<br>Ø.25 [6.4]<br>Mounting holes: 0.22’’ [5.6mm] Dia.<br>**----- End of picture text -----**<br>
## **Applications**
Winding equipment
Spooling Positioning
**www.redingtoncounters.com**
**40**
**Model 41**
**Register**
**Mechanical**
## **Description**
The Model 41 is a 3-figure or 4-figure mechanical register and is used to display gallons or liters output from a dispenser or pump. The large figure display can be reset with the rotary reset shaft. A smaller, non-reset, mechanical totalizer is also included to record total product dispensed.
## **Features**
- Large easy to read figures
- Time tested, reliable and durable
- Wide operating temperature range
## **Options**
- Gallons or liters
- Reset shaft configuration
- Reset shaft: right hand, left hand, or both
- All non-corrosive parts
- Spring loaded totalizer is pre-settable
- No lubrication required
## **Specifications**
**Figures: Main Display:** 3 or 4 figures, white on black, 0.65" [16.5mm] high **Totalizer:** 0.19” [5mm] white on black **Reset:** Rotary reset. Reset knob supplied by customer **Reset Shaft:** 0.25” [6.4mm] diameter
**Speed:** 40 gallons per/minute, 400 liters per/minute **Operation Life:** 1 million gallons, 10 million liters **Temp. Range:** -40°F to +150°F [-40°C to +65°C] **Weight:** 3-figure - 9oz [255g], 4-figure - 11oz [312g]
## **Models Description**
1-4103 3-figures, gallon display 2-4104 4-figures, gallon display
## **Models**
## **Description**
- 2-4103 3-figures, liter display
- 3-4104 4-figures, liter display
## **Dimensions**
**==> picture [33 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
3-Figure<br>**----- End of picture text -----**<br>
**==> picture [37 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
Side View<br>**----- End of picture text -----**<br>
**4-Figure**
## **Applications**
**Pumps and Flow Meters**
**www.redingtoncounters.com**
**41**
| | **Model 46**
**Stroke Counter**
**Mechanical**
**==> picture [70 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
With Lever & Spring<br>**----- End of picture text -----**<br>
With Thumb Lever
## **Description**
These 5 figure stroke counters are especially designed for limited space and high count life applications. The advanced drive system translates into exceptionally high operating speeds, extended operating life, for fast and accurate readings. Ideal for copiers, printing presses, cut-off machines, and piece-part counting applications. Also available with a thumb lever for use as a tally counter.
## **Features**
- Compact size
- • Reliability
- Low cost
## **Options**
- Special levers
- • 10011-001S - additional spring
- 10007-009S - lever and spring
## **Specifications**
**Figures:** 5 figures, white on black, 0.19’’ [5mm] high **Reset:** Standard or large knob, non-reset **Speed:** 500 counts/minute **Rotation:** Top-coming or top-going **Count Stroke:** 40° Min. - 45° Max.
**Shaft Extension:** Right-hand or left-hand **Shaft Diameter:** 0.156’’ [4.0mm] **Operating Life:** Beyond 5 million counts **Temp. Range:** -15°F to +140°F [-25°C to +60°C] **Weight:** 2 oz. [57g]
|**Models**|**Description**|**Description**||**Models**|**Description**|**Description**||
|---|---|---|---|---|---|---|---|
|**1-4615**|Left-hand,|top-coming,|standard reset knob|2-4615|Left-hand,|top-coming,|large reset knob|
|**1-4625**|Left-hand,|top-going,|standard reset knob|2-4625|Left-hand,|top-going,|large reset knob|
|**1-4635**|Right-hand,|top-coming,|standard reset knob|2-4635|Right-hand,|top-coming,|large reset knob|
|**1-4645**|Right-hand,|top-going,|standard reset knob|2-4645|Right-hand,|top-going,|large reset knob|
|**1-4635T**|Right-hand,|top-coming,|std. reset knob, with thumb lever|5-4645|Right-hand,|top-going,|non-reset|
* Items in bold are normally in factory stock.
## **Dimensions**
**==> picture [82 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
Right - Hand Shaft<br>**----- End of picture text -----**<br>
**==> picture [341 x 130] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.53 [64.3] 1.28 [32.5]<br>1.20 [30.5] 1 2 3 45 0.96 [24.4] 1.44 [36.6]<br>—<br>| [| P ( j )<br>—CO = ae [>|] | ©<br>a) | |<br>0.81 [20.6]<br>1.52 [38.6]<br>Mounting holes: 0.13’’ x 0.24’’ [3.3 x 6.1mm] slots<br>**----- End of picture text -----**<br>
## **Applications**
**==> picture [457 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
Copiers Printing presses Farm equipment Piece-part counting Cut-off machines<br>**----- End of picture text -----**<br>
**www.redingtoncounters.com**
**42**
**Revolution Counter**
**Model 750**
**Mechanical**
## **Description**
These rugged revolution counters are completely sealed, tamper resistant, and maintenance-free. They can be mounted on a rotating shaft or wheel. Adds in either direction, and records revolutions, miles, kilometers, or acres. They are used on material handling equipment, farm machinery, rapid transit vehicles, street sweepers, golf carts, and construction equipment.
## **Features**
## **Options**
- Sealed • Face plate
- • Tamper resistant • Custom calibrations
- Bi-directional
## **Specifications**
**Figures:** 7 figures, 0.19’’ [5mm] high **Temp. Range:** -50°F to +180°F [-45°C to +82°C] **Weight:** 1.5 Lbs. [0.7kg]
## **Models Description**
**Models Description**
750-0002 Reading x 10 = Total Revolutions (Revolutions) 750-0114 Reading x 100 = Revolutions (Revolutions) 750-0007 (9.5L - 15) x 15’ (Acres) 750-0156 798 Revolutions per Acre (Acres) 750-0016 364 Revolutions per Acre (Acres)
Consult factory for a counter to meet your specific needs.
## **Dimensions**
## **Hubodometer**
**==> picture [237 x 174] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.11 [53.6]<br>1.24 [31.5]<br>0.26 [6.6]<br>/\\<br>4.33 [110.0]<br>1 2 3 4 5 6 7<br>XS : WA / \<br>LS SN<br>1/2-20 UNF X 0.53 LONG<br>4.71 [119.6]<br>**----- End of picture text -----**<br>
## **Applications**
Rapid transit vehicles
**==> picture [309 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Farm machinery Golf carts Construction equipment<br>**----- End of picture text -----**<br>
**www.redingtoncounters.com**
**43**
4 **Model PCU**
**Stroke Counter**
**Mechanical**
**Description** This 3 or 4 figure stroke counter with operating lever, spring assembly and reset knob, requires minimal space for mounting plus offers a high count ~~a~~ rate and long life. The Model PCU can be reset during operation without damage. All PCU’s are designed to minimize internal contamination, making them an excellent choice for outdoor use.
## **Features**
- 3 or 4 figure
- Compact size
- Suitable for outdoor use
## **Options**
- Non-reset
- Large reset knob
## **Specifications**
**Figures:** 3 or 4 figures, white on black, 0.19’’ [5mm] high **Reset:** Knob **Speed:** 600 counts/minute **Rotation:** Top-coming or top-going **Count Stroke:** 40° Min. - 45° Max.
**Shaft Extension:** Right-hand or left-hand **Shaft Diameter:** 0.156’’ [4mm] **Operating Life:** Beyond 50 million counts **Temp. Range:** -15°F to +140°F [-26°C to +60°C] **Weight:** 2 oz. [57g]
## **Models Description**
## **Models Description**
1-PCU-13 Left-hand, top-coming, 3 figure 1-PCU-14 Left-hand, top-coming, 4 figure 1-PCU-33 Right-hand, top-coming, 3 figure 1-PCU-24 Left-hand, top-going, 4 figure 1-PCU-33T Right-hand, top-coming, 3 figure, with thumb lever 1-PCU-34 Right-hand, top-coming, 4 figure 1-PCU-43 Right-hand, top-going, 3 figure 1-PCU-44 Right-hand, top-going, 4 figure
## **Dimensions**
**==> picture [493 x 129] intentionally omitted <==**
**----- Start of picture text -----**<br>
1-PCU-13 1-PCU-14<br>4X Ø0.13 [Ø3.3]<br>1.28 [32.5] 4X Ø0.13 [Ø3.3] 1.28 [32.5]<br>2.46 [62.5]<br>0.85 [21.6] 2.39 [60.7] 0.85 [21.6]<br>Lee Le<br>1 2 3 4 1.20 [30.4]<br>1.44 [36.6] 0.96 [24.4] 1 2 3 1.20 [30.4] 1.44 [36.6] 0.96 [24.4]<br>0.74 [18.7]<br>i c e 0.67 [16.9] i c e<br>1.45 [36.9]<br>1.38 [35.2]<br>**----- End of picture text -----**<br>
**==> picture [54 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
Applications<br>**----- End of picture text -----**<br>
**==> picture [384 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
Secondary Machines Shears Farm Machinery<br>**----- End of picture text -----**<br>
**www.redingtoncounters.com**
**44**
= **Model 58**
**Predetermining Counter**
**Electromechanical**
## **Description**
Designed for use in a wide variety of production, batching and packaging applications. These 4 or 6 figure electromechanical predetermining counters count down from a preset number and activate a SPDT switch. Convenient preset controls and built-in manual reset with guard are standard. A surge absorbing circuit protects against damage due to voltage spikes. Heavy duty bail mount secures counter in place.
|**Features**||||**Options**||
|---|---|---|---|---|---|
|•<br>4 or 6 figures|4 or 6 figures|4 or 6 figures|4 or 6 figures|•|Voltages|
## **Features**
- Heavy duty mount
- SPDT switch
## **Specifications**
|**Figures:**|4 or 6 figures, white on black, 0.16’’ [4mm] high|**Termination:**||Screw type|
|---|---|---|---|---|
|**Reset:**|Manual, or electric reset (min. 100ms - on, 1min - off)|**Operating Life:**||Beyond 100 million counts|
|**Speed:**|600 counts/minute (min. 50ms - on, 50ms - off)|**Temp. Range:**||-15°F to +140°F [-26°C to + 60°C]|
|**Voltages:**|115VAC, 24VDC|**Output Switch:**||SPDT 5 Amp. @ 250 VAC resistive|
||(+/-10%, but not to exceed 10 volts)|**Output Duration:**||Until reset|
|**Power:**|5.5 watts count, 20 watts reset (nominal)|**Approvals:**||UL Recognized, CE Compliant|
|**Mounting:**|Bail|**Weight:**||10 oz. [284g]|
|**Models**|**Description**|**Models**|**Description**||
|**B2-5804**|115VAC, 4 figure, manual reset|**B2-5806**|115VAC,|6 figure, manual reset|
|B2-5804/E2|115VAC, 4 figure, 115VAC electric reset|B2-5806/E2|115VAC,|6 figure, 115VAC electric reset|
|B8-5804|24VDC,<br>4 figure, manual reset|B8-5806|24VDC,|6 figure, manual reset|
|B8-5804/E8|24VDC,<br>4 figure, 24VDC electric reset|B8-5806/E2|24VDC,|6 figure, 115VAC electric reset|
* Items in bold are normally in factory stock.
## **Dimensions**
**==> picture [418 x 180] intentionally omitted <==**
**----- Start of picture text -----**<br>
Bail Mount<br>2.36 [60.0]<br>0.28 [7.0] 2.83 [71.8] 0.67 [17.0]<br>a<br>1 2 3 4<br>2.36 [60.0]<br>a=:<br>Panel cutout: 2.17’’ x 2.17’’ [55.1 x 55.1]<br>Applications<br>Packaging Batching<br>**----- End of picture text -----**<br>
**==> picture [38 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
Production<br>**----- End of picture text -----**<br>
**www.redingtoncounters.com**
**45**
**LCD Hour Meter**
**Model 33**
**Electronic**
## **Description**
The Redington Model 33 line of LCD hour meters provides a large display, 7mm high figures, in the industry size housings. The hour meters are available in a variety of mountings: 2-hole rectangular, 3-hole round, flush-round and flush-rectangular. Voltage operating ranges are 10277 VDC AND 20-277VAC 50/60Hz. All models are totally sealed from moisture and dirt and conform to NEMA 4 & 4X specifications when mounted with the optional gasket. Their rugged construction makes them ideal replacements for current hour meters. Units have polarized LCD for high visibility in sunlight.
## **Features**
## **Options**
- AC or DC voltage input in the same unit
- Totally sealed from moisture and dirt
- Run indicator-blinking decimal point
- Always on display
- Compact depth
- AC Voltage input is not frequency sensitive
- Clip retainer mount or screws (supplied)
- Custom logos and bezels
-
- Terminations
- Remote reset - dry contact with 6” wire leads
- Gaskets
- 5003-002S gasket for 2-hole mount 5003-003S gasket for flush-rectangular mount 5003-004S gasket for flush-round mount 5003-005S gasket for 3-hole round mount
## **Specifications**
**Display:** LCD with large 0.28” [7mm] high figures, black on light background **Run Indicator:** Blinking decimal point **Quartz Accuracy:** 0.02% over entire voltage & temperature range **Records & Displays:** 6 digit (99999.9) **Inputs:** 10 to 277VDC AND 20-277VAC-50/60Hz Vih* 20VAC or 10VDC minimum Vil* 3VAC or 3VDC maximum **Battery Life:** 7+ years **Shock:** 44 to 55g’s, SAE J1378 **Vibration:** 20 g @ 10 to 80 Hz, SAE J1378 **Humidity:** 95% SAE J1378
**Operating Temperature:** -40°F to +185°F [-40°C to +85°C] **Sealing:** Totally sealed, panel gaskets-NEMA 4 & 4X **Agency Approvals:** CE compliant UL/cUL recognized (file# ELIY2.E36690) **Termination:** 0.250” [6.4mm] spades **Reset:** Optional - dry contact with 6” wire leads **Case Material:** Polymer (black) **Weight:** 1oz [28g] **Protection Against:** Alternator load dump: 150V EMI(Electromagnetic Interference): +400V @ 500Hz inductive switching and reverse polarity
- Vih is the input high voltage. This is specified as the minimum input voltage that the Model 33 will recognize as a high level. Vil is the input low voltage. This is specified as the maximum input voltage that the Model 33 will recognize as a low level.
Note: When interfacing the Model 33 with a Solid State Relay or AC Sensor, the leakage current needs to be considered. Contact the factory or see the application note at www.redingtoncounters.com for further information.
|**Models**|**Description**|**Description**|**Models**|**Description**|**Description**|
|---|---|---|---|---|---|
|**3311-0000**|2-Hole Rect.,|10-277 VDC AND 20-277VAC|**3311-0010**|2-Hole Rect.,|10-277 VDC AND 20-277VAC, remote reset|
|**3311-1000**|3-Hole Round,|10-277 VDC AND 20-277VAC|**3311-1010**|3-Hole Round,|10-277 VDC AND 20-277VAC, remote reset|
|**3311-2000**|Flush Rect.,|10-277 VDC AND 20-277VAC|**3311-2010**|Flush Rect.,|10-277 VDC AND 20-277VAC, remote reset|
|**3311-3000**|Flush-Round,|10-277 VDC AND 20-277VAC|**3311-3010**|Flush-Round,|10-277 VDC AND 20-277VAC, remote reset|
|All parts are normally in factory stock.|All parts are normally in factory stock.|||||
**www.redingtoncounters.com**
**46**
| am **Model 33**
**LCD Hour Meter**
**Electronic**
## **Dimensions**
**==> picture [251 x 165] intentionally omitted <==**
**----- Start of picture text -----**<br>
2-Hole<br>2.04 [51.9]<br>0.44 [11.2]<br>1.75 [44.4]<br>0.34 [8.7]<br>ot.<br>1.10 [27.9] 0.89 [22.6] 0.93 [23.5]<br>0.28 [7.0]<br>Ø.15 [Ø3.8]<br>1.41 [35.8]<br>0.06 [1.5]<br>1 ef<br>I<br>0.06 [1.5]<br>wwA<br>0.25 [6.3]<br>0.99 [25.1]<br>1.43 [36.2]<br>**----- End of picture text -----**<br>
**==> picture [61 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
3-Hole Round<br>**----- End of picture text -----**<br>
**==> picture [289 x 170] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.44 [11.2]<br>0.44 [11.2]<br>0.34 [8.7]<br>0.34 [8.7]<br>ot. aa<br>0.93 [23.5] Ø2.86 [72.6] 0.93 [23.5]<br>0.28 [7.0]<br>S rie.<br>0.12 [3.0]<br>3X Ø.13 [Ø3.2] EQUALLY SPACED<br>- ON A 2.53[89.7] B.C.<br>a<br>_j 0.25 [6.3]<br>0.99 [25.1]<br>1.43 [36.2]<br>Panel cutout: 1.45 X 0.95 [24.0 x 37.0]<br>**----- End of picture text -----**<br>
In-front panel cutout: 1.45 X 0.95 [24.0 x 37.0] Behind panel cutout: 1.42 X 0.90 [22.9 x 36.1]
## **Flush-Round**
**==> picture [215 x 154] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.44 [11.2]<br>0.34 [8.7]<br>Ø2.27 [57.7] 0.93 [23.5]<br>0.28 [7.0]<br>——— 0.12 [3.0]<br>0.25 [6.3]<br>0.99 [25.1]<br>1.43 [36.2]<br>**----- End of picture text -----**<br>
## **Flush-Rectangular**
**==> picture [218 x 142] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.44 [11.2]<br>1.60 [40.6]<br>0.34 [8.7]<br>1.10 [27.9]<br>0.89 [22.6] 0.93 [23.5]<br>0.28 [7.0]<br>1.41 [35.8]<br>0.06 [1.5]<br>0.06 [1.5]<br>I 0.25 [6.3]<br>0.99 [25.1]<br>1.43 [36.2]<br>**----- End of picture text -----**<br>
Panel cutout: 1.45 X 0.95 [24.0 x 37.0] Maximum panel thickness: 0.15 [3.8]
Panel cutout: 1.45 X 0.95 [24.0 x 37.0] Maximum panel thickness: 0.15 [3.8]
## **Applications**
**==> picture [183 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Agricultural Equipment Medical Devices<br>**----- End of picture text -----**<br>
**==> picture [81 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Construction Equipment<br>**----- End of picture text -----**<br>
**==> picture [66 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Marine Applications<br>**----- End of picture text -----**<br>
**==> picture [37 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
Boom Lifts<br>**----- End of picture text -----**<br>
**==> picture [53 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Test Equipment<br>**----- End of picture text -----**<br>
**==> picture [182 x 153] intentionally omitted <==**
**----- Start of picture text -----**<br>
Pressure Washers Sweepers<br>aay o—<br>Generators Office Equipment<br>; Ap _ PN<br>} f\ BAH aos<br>or Sky<br>Compressors Utility Vehicles<br>**----- End of picture text -----**<br>
**www.redingtoncounters.com**
**47**
**LCD Hour Meter/Maintenance Meter**
**==> picture [231 x 15] intentionally omitted <==**
**----- Start of picture text -----**<br>
| | Model 51 Electronic<br>**----- End of picture text -----**<br>
## **Description**
The Redington Model 51 line of 5 figure LCD meters provides a large display in the industry size package. A choice of mountings, Round, 2 Hole Dual, Mini Rectangular or Surface Mount. A custom microprocessor, capable of being programmed to create an almost infinite matrix of models is ideally suited for OEM applications. Available in 3 inputs, DC, AC or Inductive. Maintenance Meters are offered with a “Redi-Alert” to alert users when service is due. Not only does the display flash to get attention, but it displays specific maintenance service needs to be done. Units have Polarized LCD for high visibility in sunlight. Servicing equipment on time is critical to efficient operation and long equipment life. That is why you should consider Redington’s “Redi-Alert” meters. Redi- Alert offers two independent alarms (both fully programmable) to alert users when service is due. Alarms are fully automatic; coming on and shutting off at times determined by the OEM.
## **Features**
- Totally sealed from moisture and dirt
- Fits in existing panel openings
- “Redi-Alert” for preventive maintenance
- Icons for specific maintenance needs
- Tachometer/Hour Meter versions
- Automatic rollover
## **Options**
- Various voltage inputs
- Alarm outputs: audible or visual (external voltagerequired)
- • Custom logos & bezels
- Terminations: stud, wire, screw, or blade
- Alternator and filtered versions
- Key Kancel (alarm reset via external key or wand)
- Hour glass symbol appears & flashes on/off to indicate running time
- Various voltage inputs
- Short depth
- Always on display
## **Specifications**
**Display:** Large 0.20” [5mm] LCD, black on light background **Records & Displays:** 5 digits (9999.9) **Resolution:** 0.1 hours **Quartz Accuracy:** 0.02% over entire voltage & temp. range **Inputs:** 8-32 VDC, 32-277 VAC-50/60HZ **Operating Temperature:** -40°F to +160°F [-40°C to +71°C] **Battery Life:** 15 years **Current Consumption:** 1 mA (for multi-range voltages 1 mA applies to lower voltage) **Approvals:** AC-UL/cUL Recognized, CE Compliant
**Protection Against:** Transient voltage, inductive switching, reverse polarity, frequency variations **Alternator Load Dump:** 150 V **Shock:** SAE J1378 55g **Vibration:** SAE J1378 20g **Humidity:** SAE J1378 95% RH **Termination:** Panel mount standard terminals, 0.250 male blade (s), surface mount- wire lead **Case Material:** ABS, black, 100% epoxy filled **Weight:** 1 oz. [28g]
## **Models Description**
**DC Models 5120-1000** Panel Mount, Round, 8-32 VDC, Hours & 1/10’s **5120-1100** Panel Mount, Mini, 8-32 VDC, Hours & 1/10’s **5120-1200** Panel Mount, 2 Hole, 8-32 VDC, Hours & 1/10’s
**AC Models 5120-2000** Panel Mount, Round, 32-277VAC, 50/60 Hz, Hours & 1/10’s 5120-2100 Panel Mount, Mini, 32-277 VAC, 50/60 Hz, Hours & 1/10’s 5120-2200 Panel Mount, 2 Hole, 32-277 VAC, 50/60 Hz, Hours & 1/10’s
* Items in bold are normally in factory stock.
## **Models Description**
## **Inductive Models**
5120-0000 Panel Mount, Round, Inductive, Hours 5120-0100 Panel Mount, Mini, Inductive, Hours 5120-0200 Panel Mount, 2 Hole, Inductive, Hours 5140-0000 Panel Mount, Round, Inductive, Hours & 1:1Tach 5140-0100 Panel Mount, Mini, Inductive, Hours & 1:1Tach. 5140-0200 Panel Mount, 2 Hole, Inductive, Hours & 1:1Tach. 5120-0310 Surface Mount, Inductive, Hours **5140-0311** Surface Mount, Inductive, Hours w/1:1Tach. Change oil Alert @ 25hr./2 hr. flash Lube Alert @ 25hr./2 hr. flash 5140-0312 Surface Mount, Inductive, Hours w/1:1Tach. Change oil Alert @ 100hr./4 hr. flash Lube Alert @ 25 1hr./2 hr. flash
**www.redingtoncounters.com**
**48**
4 **Model 51**
**Electronic**
**LCD Hour Meter/Maintenance Meter**
**Alarm Specifications**
## _**Alarms programmable for your applications**_ **ALARM # 1**
Programmable for a “first time” (break in service) or a normal recurring service interval.
## **ALARM # 2**
Same as alarm # 1, but without the “first time” interval.
## **MAINTENANCE METER ALARM SPECIFICATIONS ALARM #1**
1[st] time service interval range (2 to 99 hrs. occurs only once)
Normal service interval range: 2 to 999 hrs. (Recurring)
Available icons: CHG OIL, LUBE, CHG MUFF, SVC-AIR FILTER, SVC-Lower left/right side of display
Flash duration: 1 to 99 hrs. (Time flashing before & after service interval)
## **ALARM/ FLASH DURATION**
## **ALARM # 2**
OEM’s specify the service interval and flash duration for each alarm. Flash duration is the amount of time in hours that the specified icon flashes before and after the service interval.
Normal service interval range: 2 to 999 hrs. (Recurring)
Flash duration: 1 to 99 hrs. (Time flashing before & after service interval)
Available icons: CHG OIL, LUBE, CHG MUFF, SVC-AIR FILTER, SVC-Lower left/right side of display
## **ALARM RESET**
**==> picture [422 x 351] intentionally omitted <==**
**----- Start of picture text -----**<br>
The standard alarm alert is fully automatic with no operator interface<br>necessary. The alarm simply flashes the specified icon for the duration<br>called out by the OEM. Controlled reset options are available for a higher out alarm duration.<br>level of security. Contact factory for additional information.<br>Dimensions<br>2 Hole Dual Mount Round<br>0.15 [3.9]<br>1.75 [44.5] 0.10 [2.6]<br>1.40 [35.6] 0.75 [19.1]<br>2.30 [58.4]<br>1.08 [27.4] 0.92 [23.4] 0.94 [23.9]<br>R0.10 [R2.5]<br>Ø0.15 [Ø3.8]<br>esis Th (©) 0.21 [5.2]<br>Above panel cutout 1.46 x 0.95 [37.1 x 24.1] opening Spring clip retainer, Fast installation<br>Behind panel cutout 1.41 x 0.93 [35.8 x 23.6] opening Panel cutout 2.0 [50.8] diameter<br>Surface Mount Mini Rectangular<br>2.12 [53.8] 0.50 [12.7]<br>1.75 [44.5]<br>1.39 [35.3]<br>1.08 [27.4]<br>| 4 |<br>R0.20 [R5.1] = | fee] R0.20 [R5.1] 4pJe<br>22 Gauge<br>Mounting holes are 1 1/2” [38.1] spacing<br>Hole Diameter is 1/8” [3.2]<br>**----- End of picture text -----**<br>
Alarms flash specified icon 4 seconds then flash hour 4 seconds throughout alarm duration.
**==> picture [214 x 289] intentionally omitted <==**
**----- Start of picture text -----**<br>
Round<br>0.75 [19.1]<br>2.30 [58.4] 1.98 [50.3]<br>0.05 [1.3]<br>0.13 [3.3]<br>(©) 0.21 [5.2]<br>Spring clip retainer, Fast installation<br> Panel cutout 2.0 [50.8] diameter<br>Mini Rectangular<br>1.75 [44.5] 0.75 [19.1]<br>1.08 [27.4] 0.94 [23.9]<br>| 4 | 4<br>fee] R0.20 [R5.1] 4pJe 0.10 [2.5]<br>Compact Bezel Design, Spring clip retainer, Fast<br>installation, Panel cutout 1.46 x 0.95 [37.1 x 24.1] opening.<br>**----- End of picture text -----**<br>
## **Applications**
**==> picture [260 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
Construction Equipment Medical Devices Generators<br>**----- End of picture text -----**<br>
**==> picture [69 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Marine Applications<br>**----- End of picture text -----**<br>
**==> picture [59 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
Garden Tractors<br>**----- End of picture text -----**<br>
**www.redingtoncounters.com**
**49**
**Model 53**
**Electronic**
**LCD Hour Meter**
## **Description**
The Model 53 Hour Meter with 7 LCD digits, 999999.9, and internal lithium battery, is ideal for applications requiring time accumulation for maintenance scheduling, warranty monitoring, lease time or fee computation. Applications include test equipment, panel builders, mobile equipment and medical devices. A choice of time ranges, in hours, minutes or seconds provides the user with a wide choice of recording increments.
**Features Options •** Lithium battery **•** Termination **•** Choice of manual reset, remote reset or non-reset **•** Case color **•** Switch (no-voltage), 3-30VDC, 20-250VAC/VDC **•** Private labeling **•** Mounting adapter plates • 5003-001S - gasket • Low AC voltage (4-30 VAC)
## **Specifications**
**Figures:** 7 LCD figures, 0.32’’ [8mm] high **Temperature Reset:** Remote, manual, and non-reset **Operating:** -4°F to +140°F [-20°C to +60°C] **Inputs:** Switch (no-voltage), 3-30VDC, 20-250VAC/VDC (50/60Hz) **Storage:** -40°F to +165°F [-40°C to +75°C] Vih* 20VAC/3VDC minimum **Humidity:** 0 to 95% RH, non-condensing Vil* 3VAC/1VDC maximum **Vibration Power:** Self-powered (internal lithium battery) **Operating:** 10 to 55Hz, 0.01” [0.25mm] double amplitude **Mounting:** Panel with clip **Non-Operating:** 10 to 55Hz, 0.03” [0.75mm] double amplitude **Terminations:** Terminal block, or connector - 8’’ [200mm] wire leads **Shock Weight:** 2 oz. [57g] **Operating:** 10G **Battery Life:** ~20years **Non-Operating:** 30G **Accuracy:** Quartz accuracy (better than 0.01%) **Dielectric:** 1000VAC 50/60Hz for 1 minute **Approvals:** UL Recognized, CSA Certified, CE Compliant
Note: When interfacing the Model 53 with a Solid State Relay or AC Sensor, the leakage current need to be considered. Contact the factory or see the application note at www.redingtoncounters.com for further information. **Models**
**==> picture [472 x 193] intentionally omitted <==**
**----- Start of picture text -----**<br>
Part# Function Reset Input Terminations Color<br>a hours min. sec. remote none manual switch 3-30VDC 20-250VAC/VDC term. block 8” wire leads tan black<br>5320-0000 X X X X X<br>5320-0001 X X X X X<br>5321-0000 X X X X X<br>5321-0001 X X X X X<br>5322-0000 X X X X X<br>5322-0001 X X X X X<br>5320-0100 X X X X X X<br>5320-0101 X X X X X X<br>5320-1000 X X X X X<br>5320-1001 X X X X X<br>5320-1010 X X X X X<br>5320-1011 X X X X X<br>TEE 5320-20005320-1100 XX XX X X X EE XX XX<br>5320-2001 X X X X X<br>5320-2200 X X X X X<br>5320-2201 X X X X X<br>THEE 5320-2100 X X X EE X EE X IE X<br>**----- End of picture text -----**<br>
* Items in bold are normally in factory stock.
**www.redingtoncounters.com**
**50**
L | | **Model 53**
**Electronic**
**LCD Hour Meter**
**Dimensions**
## **TERMINAL BLOCK**
## **WIRE LEADS**
**==> picture [502 x 198] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.72 [43.7] 1.58 [40.0]<br>1.92 [48.8] 1.92 [48.8]<br>0.10 [2.5] 1.47 [37.3]<br>0.10 [2.5] 1.47 [37.3]<br>ee Oe a ee |<br>Pac Pa Pac at at Pa Pa mi 1.02 [25.9] 0.86 [21.8] Tau De Dac ft<br>DOLIDALILILULE LALO! 1.02 [25.9] 0.86 [21.8]<br>Operating Instructions<br>MOUNTING: 1.79 +/- 0.01<br> [45.5 +1/-0]<br>0.89 +/- 0.01 Panel Cutout<br> [22.6 +1/-0]<br>Optional<br>Unit<br>Gasket Panel Clip The mounting clip accommodates panel thicknesses up to 1/4”<br>**----- End of picture text -----**<br>
The mounting clip accommodates panel thicknesses up to 1/4” [6.4mm].
**==> picture [38 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
WIRING:<br>**----- End of picture text -----**<br>
**==> picture [201 x 214] intentionally omitted <==**
**----- Start of picture text -----**<br>
SWITCH (non-voltage)<br>1 2 3 4 5<br>INPUT RESET<br>et.<br> (Pin 1 is not used)<br>3 - 30 VDC<br>1 2 3 4 5<br>INPUT +DC +DC RESET<br>— Lit<br> (Pin 1 is not used)<br>20 - 250VAC/VDC<br>1 2 3 4 5<br>INPUT AC/DC AC/DC RESET<br>a fesjjtt..<br> (Pin 1 is not used)<br>**----- End of picture text -----**<br>
Panel adapter plates are available in flush and 2 hole mount to fit various panel cutouts. Consult the factory for availability.
Color code for the 8” [203mm] lead wires (24AWG) are:
- 1 - Yellow
- 2 - Blue
- 3 - Black
- 4 - Violet
- 5 - Gray
Terminal block will accept wire sizes from 14 to 24AWG.
3 - 30VDC units are protected for transient voltages up to 50 volts with pulse widths of up to 1 second at a 1% duty cycle (including reverse polarity).
The operating AC frequency range is 40 to 400Hz.
## **NOTES:**
All resettable hour meters can be reset by a pulse with a minimum duration of 6 milliseconds.
## **SPECIAL WIRING OPTION**
There is an internal connection between pin 3 and pin 5, a single wire can be used by connecting it to either pin 3 or pin 5. This option **does not** apply for units with input of 20 - 250VAC/VDC or manual reset enable.
## **OPTIONAL INPUTS:**
Optional control circuity (such as transistors) may be used as inputs provided that such circuitry provides the required parameters of the model used.
## **Applications**
Medical Equipment
Test Equipment
Office Equipment
**www.redingtoncounters.com**
**51**
**LCD Hour Meter/Counter**
**Electronic**
am **Model 55**
## **Description**
The Model 55 LCD hour meters and counters offer a flexible choice for basic hour meter or counter function. Three variations of cases make the Model 55 flexible for your installation requirements. Because all information is saved in an internal EEPROM memory, no battery is required. A broad range of AC or DC input voltages make the Model 55 a versatile product for most applications. Two operating versions of the hour meter and three operating versions of the counter are offered. These include hour meters that display hours to resolutions of 1/100[th] or 1/10[th] of an hours and counters that operate with maximum input rates of 30 Hz or 200 Hz for DC inputs and 10 Hz for AC inputs. The Model 55 includes models with reset options that include remote reset, manual and remote reset, and non-reset. A model designed to mount to a printed circuit board is available upon request.
- **Features Options** • Manual, remote or non-reset • 1/10[th] or 1/100[th] hour indication, or counts • EEPROM for memory (no battery) • Reset type • AC or DC input voltages • Case configuration • 3 housing configurations • Termination • 1/10[th] or 1/100[th] hours indication • Count speed
- IP 65 front panel, without reset button
- Display hours or counts
- Choice of count frequency
## **Specifications**
**Figures:** 7 LCD figures, 0.28’’ [7mm] high **Operating Temp:** -22 °F to +158 °F [-30°C to +70°C] **Quartz Accuracy** : 0.01% **Humidity:** 0 to 95% RH, non-condensing **Reset:** Manual and remote, non-reset and remote only **Protection:** Without reset button-IP 65, gasket supplied, No manual reset for round model With reset button-IP54 **Input Voltage:** 12/24 VDC ±25% **EMC:** EN 55011, EN 50082-2 115-240 VAC ±10% 50/60 Hz **Vibration:** 1 g (10-500 Hz) IEC 68-2-34 **Special Voltage:** 24 VAC/DC ±10%, 24-48 VDC ±25% **Shock:** 30 g (18 msec.) IEC 68-2-27 **Current:** 12-24 VDC & 24-48 VDC/2-4 mA 25 g (6 msec.) IEC 68-2-29 24 VAC/DC/2 mA **Max Count Speed:** 30, 200 Hz DC or (10 Hz AC or AC/DC) 115-240 VAC/7- 15 mA **Memory:** EEPROM (no battery) **Mounting:** Retaining clip **Case Material:** Black, ABS plastic with glass lens on round **Terminations:** 1/4” spade or screw terminals model only **Approvals:** UL Recognized, CE Compliant **Weight:** 2 oz. [57g]
## **Models Description**
For Details on Models and Descriptions, see the Ordering Information section.
## **Applications**
**==> picture [221 x 78] intentionally omitted <==**
**----- Start of picture text -----**<br>
Test equipment Compressors<br>Packaging machinery Panel builders<br>**----- End of picture text -----**<br>
**==> picture [57 x 77] intentionally omitted <==**
**----- Start of picture text -----**<br>
Piece count<br>Medical devices<br>**----- End of picture text -----**<br>
**www.redingtoncounters.com**
**52**
on **Model 55**
**LCD Hour Meter/Counter**
**Electronic**
## **Dimensions**
**==> picture [485 x 233] intentionally omitted <==**
**----- Start of picture text -----**<br>
Round Square<br>1.77 [45.0]<br>1.50 [38.0]<br>1.47 [37.3]<br>0.31 [8.0]<br>al =<br>—~1 Ø2.20 [56.0] onl 0.12 [3.0]<br>cS Ø2.04 [51.7] — 1.89 [48.0] —<br>(wagaeael || | |<br>1.89 [48.0] 1.77 [45.0]<br>| | | (lo) aaaesee)<br>VY | io<br>JF | Peyy}<br>PANEL CUT OUT: Ø2.055 [52.2] PANEL CUT OUT: 1.78 [45.2] SQUARE<br>**----- End of picture text -----**<br>
**Rectangular**
**Mounting Clip**
1.77 [45.0]
**==> picture [226 x 138] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.47 [37.3]<br>Ps<br>0.12 [3.0]<br>1.89 [48.0]<br>—<br>0.94 [24.0] 0.87 [22.0]<br>ah os<br>**----- End of picture text -----**<br>
**==> picture [218 x 138] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.97 [49.9]<br>0.89 [22.6] 1.03 [26.2]<br>7<br>1.83 [46.4]<br>ca} 2.11 [53.5] 0.10 [2.5]<br>0.10 [2.5]<br>0.17 [4.3]<br>0.38 [9.5]<br>0.18 [4.5]<br>tr<br>**----- End of picture text -----**<br>
PANEL CUT OUT: .876 [22.2] X 1.772 [45]
Maximum Panel Thickness for all units: 0.15’’ [6.4mm]
## **Wiring Diagram**
**www.redingtoncounters.com**
**53**
**LCD Hour Meter/Counter**
|**Model 55**<br>**Electronic**|**Model 55**<br>**Electronic**||**LCD Hour Meter/Counter**|**LCD Hour Meter/Counter**|**LCD Hour Meter/Counter**|**LCD Hour Meter/Counter**|**LCD Hour Meter/Counter**|**LCD Hour Meter/Counter**|**LCD Hour Meter/Counter**|**LCD Hour Meter/Counter**|
|---|---|---|---|---|---|---|---|---|---|---|
||||5 5 x x - x x x x|5 5 x x - x x x x|||||||
|**TYPE**<br>**HOUSING**<br>**STYLE**<br>**VOLTAGE**<br>**RESET**<br>**READOUT**<br>**MAX. SPEED**<br>**TERMINALS**|55<br>PRODUCT NUMBER<br>0<br>COUNTER<br>1<br>HOUR METER<br>0<br>0.94’’ X 1.90’’ [24 X 48 mm] RECTANGULAR<br>1<br>1.90’’ X 1.90’’ [48 X 48 mm] SQUARE<br>2<br>2.2” [56 mm] ROUND<br>0<br>12 - 24 VDC<br>1<br>*24 - 48 VDC<br>2<br>*24 VAC/VDC<br>3<br>115 - 240 VAC 50/60 Hz<br>0<br>NON-RESET<br>1<br>REMOTE ONLY RESET<br>2<br>**MANUAL & REMOTE RESET<br>0<br>1/10 HOUR<br>(HOUR METER)<br>1<br>1/100 HOUR<br>(HOUR METER)<br>2<br>DC (30 Hz)<br>(COUNTER)<br>3<br>DC (200 Hz)<br>(COUNTER)<br>4<br>AC or AC/DC (10 Hz)<br>(COUNTER)<br>0<br>1/4” SPADE<br>1<br>SCREW TERMINALS<br>* Special voltage - consult factory<br>=||||||||||
||** Manual reset not available on round case style.||||||||||
|_Note: The counter display is updated on the trailing edge of the input signal._|_Note: The counter display is updated on the trailing edge of the input signal._||||||||||
|**54**|**www.redingtoncounters.com**||||||||||
**54**
|[|}] **Model 56**
**LCD Hour/Counter/Maintenance Meter**
**Electronic**
## **Description**
The Redington Model 56 family of LCD indicators offers a variety of options to fulfill your count/hour meter requirements. This indicator can display hours, counts or both with a single-line shared display. You decide which value should be displayed permanently and which one will be in the background. The background indication will appear for approximately 10 seconds every time you apply power to the meter.
The Model 56 family offers you many features that are set at the factory at your request. These features include, input voltages, maximum count speeds or minimum hour meter indication times, connector terminations, reset configurations, a Redi-Alert Service Interval feature, prewarn, and input scaling.
The Model 56 family can be ordered to accommodate any of a number of AC or DC input voltages and reset configurations. The counter can be ordered for maximum input count speeds of 10 Hz for AC or AC/DC voltages and 30 Hz or 200 Hz for DC voltages. The hour meter can be ordered to display time intervals of 1/100[th] or 1/10[th] of hours. When using a counter and an hour meter in combination, the counter will count the number of input pulses while the hour meter will record the total duration of the input pulses.
The Redi-Alert Service Interval feature notifies operators of service requirements when service intervals are a function of the number of events or time. If a Redi-Alert Service Interval is specified, the display will show the count (or time) remaining until the service interval is reached. The RediAlert Service Interval feature can be considered to be a down-counter (or down-timer) since the count (or time) that is displayed shows what remains until service is required. When the Redi-Alert Service Interval gets to zero, the indicator will flash the display. If the Redi-Alert Service Interval is not reset, the indicator will continue to operate, and the display will show negative counts (or time) indicating how far the system has gone past the service interval. If the prewarn feature is included, the display will begin flashing when the prewarn count (or time) is reached. When the Service Interval is in the background, it will come to the foreground when it reaches the service interval or the prewarn. Resetting the indicator resets the Service Interval to its specified setting and returns the Service Interval to the background.
You can configure your Model 56 meter using the Ordering Information sheet.
## **Features Options**
- Display hours or hours and counts
- “Redi-Alert” for service hours or counts
- Manual, remote or non-reset
- EEPROM for memory (no battery)
- **•** Divider/multiplier on inputs **•** AC or DC input voltage
- Input scaling
- **•** Input frequency **•** Reset type **•** Indication of time/count
- Wide selection of input voltage
- Service “Redi-Alert”
- 3 housing configurations
- Choice of 1/100[th] or 1/10[th] hours (specify)
## **Specifications**
**Display:** 7 digit, 0.28 [7mm], LCD, 1 display **Quartz Accuracy:** 0.01% **Input Voltage:** 12/24 VDC/ ±25% 115-240 VAC 50/60 Hz/±10% **Special Voltages:** 24-48 VDC/±25% 24 VAC 50/60 Hz/VDC/±10% **Current Consumption:** 12-24 VDC & 24-48 VDC/2-4 mA 24 VAC/VDC/2 mA 115-240 VAC/7-15 mA **Protection:** Without reset button-IP 65, gasket supplied, with reset button-IP54 **EMC:** EN 55011, EN 50082-2 **Vibration:** 1 g (10-500) IEC 68-2-34 **Shock:** 30 g (18 msec.) IEC 68-2-27 25 g (6 msec.) IEC 68-2-29 **Max. Count Speed:** 30, 200Hz DC or (10 Hz AC or AC/DC) (specify)
**Memory:** EEPROM (no battery) **Approvals:** UL Recognized, CE Compliant **Mounting:** Retaining clip **Electrical Connection:** 1/4” [6.4mm] spade or screw terminals **Case Material:** Black, ABS plastic with glass lens on round model only **Reset:** Manual and remote, non-reset and remote only No manual reset for round model **Operating Temperature:** -22°F to +158°F [-30°C to +70°C] **Weight:** 2 oz [57g] **Service Alert:** Factory set - one “Redi-Alert”, 4 digits **Input Scaling:** Factory set, 4 digits **Prewarn Signal:** Factory set, 4 digits
**www.redingtoncounters.com**
**55**
| | **Model 56**
**LCD Hour/Counter/Maintenance Meter**
**Electronic**
## **Models Description**
For Details on Models and Descriptions, see the Ordering Information section.
## **Dimensions**
**==> picture [473 x 386] intentionally omitted <==**
**----- Start of picture text -----**<br>
Round Square<br>1.77 [45.0]<br>J 1.50 [38.0] |<br>1.47 [37.3]<br>0.31 [8.0]<br>Eo Ø2.20 [56.0] 0.12 [3.0] ;<br>1.89 [48.0]<br>Ø2.04 [51.7]<br>1.89 [48.0] 1.77 [45.0]<br>oe / SGEEEEEEGTT 1|) Oo [<br>et fT<br>—_ —*iii |<br>PANEL CUT OUT: Ø2.055 [52.2] PANEL CUT OUT: 1.78 [45.2] SQUARE<br>Rectangular Mounting Clip<br>1.77 [45.0]<br>1.97 [49.9]<br>1.47 [37.3]<br>0.89 [22.6] 1.03 [26.2]<br>_ —_<br>mal 0.12 [3.0] c ma}is 1.83 [46.4]<br>1.89 [48.0] 2.11 [53.5] 0.10 [2.5]<br>0.10 [2.5]<br>— Wo St<br>0.94 [24.0] 0.87 [22.0] 0.17 [4.3] 0.38 [9.5]<br>0.18 [4.5]<br>PANEL CUT OUT: .876 [22.2] X 1.772 [45]<br>**----- End of picture text -----**<br>
Maximum Panel Thickness for all units: 0.15’’ [6.4mm]
## **Wiring Diagram**
**==> picture [54 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
Applications<br>**----- End of picture text -----**<br>
**==> picture [54 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Test Equipment<br>**----- End of picture text -----**<br>
**==> picture [76 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Packaging Machinery<br>**----- End of picture text -----**<br>
**==> picture [59 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
Medical Devices<br>**----- End of picture text -----**<br>
**www.redingtoncounters.com**
**56**
|} **Model 56**
**LCD Hour/Counter/Maintenance Meter**
**Electronic**
## **Ordering Information**
|**FUNCTION**|**HOUSING DIMENSIONS**|**HOUSING DIMENSIONS**|**HOUSING DIMENSIONS**|**NOTES**|
|---|---|---|---|---|
||**1 X 2 INCH**|**2 X 2 INCH ROUND 2.2 INCH**|**2 X 2 INCH ROUND 2.2 INCH**||
|HM WITH HM (bg)*|5600|5601|5602|Only HM is resettable|
|C WITH C (bg)*|5610|5611|5612|Only C is resettable|
|HM WITH C (bg)*|5620|5621|5622|Both are resettable|
|C WITH HM (bg)*|5630|5631|5632|Both are resettable|
|HM WITH SHM (bg)*|5640|5641|5642|Only SHM (bg) is resettable|
|C WITH SC (bg)*|5650|5651|5652|Only SC (bg) is resettable|
|SHM WITH HM (bg)*|5660|5661|5662|Only SHM is resettable|
|SC WITH C (bg*)|5670|5671|5672|Only SC is resettable|
_*HM= Hour Meter *C= Counter *bg= Background *SHM= Service Hour Meter *SC= Service Counter_
Note: The _counter display is updated on the trailing edge of the input signal_
**==> picture [446 x 372] intentionally omitted <==**
**----- Start of picture text -----**<br>
Model 56<br>Specification Sheet<br>Company: __________________________ Phone: ____________________<br>Address: __________________________ Fax: ____________________<br>__________________________ Email: ____________________<br>Contact: __________________________ Date: ____________________<br>Model No. ___________ (4 digits) SELECTED FROM ABOVE TABLE .<br>Input Voltage: (check only 1)<br> 12-24 VDC 115-240 VAC 50/60 Hz Special voltages available, consult factory.<br>Oo Oo<br>Indication of time for Hour Meter: (check only 1)<br>Oo 1/100 [th] Oo 1/10 [th]<br>Max. counting frequency for Counter: (check only 1)<br> 30 Hz (DC) 200 Hz (DC) 10 Hz @ (AC) or (AC/DC)<br>Oo Oo o<br>Termination : (check only 1)<br> 1/4” spade screw terminals<br>Oo Oo<br>Reset Types: (check only 1)<br>o non-reset o remote reset o remote and manual reset (No manual reset for 2.2 “ Round Model)<br>Service Interval: (optional)<br> “Redi-Alert” : (4 digits max) Prewarn : (4 digits max)<br>Oo a Oo a<br>Input scaling: (optional - check only 1)<br> Divider: (4 digits max) Multiplier: (4 digits max)<br>Oo e e Oo a<br>**----- End of picture text -----**<br>
**www.redingtoncounters.com**
**57**
| | **Model 57**
**LCD Hour/Counter/Maintenance Meter**
**Electronic**
## **Description**
The Redington Model 57 family of LCD indicators offers a variety of options to fulfill your count/hour meter requirements. This indicator can display hours, counts or both with a single-line shared display. This model is available with an LED indication for service and relay or transistor output. You decide which value should be displayed permanently and which one will be in the background. The background indication will appear for approximately 10 seconds every time you apply power to the meter.
When using a counter and an hour meter in combination, the counter will count the number of input pulses while the hour meter will record the total duration of the input pulses.
The Redi-Alert Service Interval feature notifies operators of service requirements when service intervals are a function of the number of events or time. If a Redi-Alert Service Interval is specified, the display will show the count (or time) remaining until the service interval is reached. The RediAlert Service Interval feature can be considered to be a down-counter (or down-timer) since the count (or time) that is displayed shows what remains until service is required. When the Redi-Alert Service Interval gets to zero, the indicator will flash the display. If the Redi-Alert Service Interval is not reset, the indicator will continue to operate, and the display will show negative counts (or time) indicating how far the system has gone past the service interval. If the prewarn feature is included, the display will begin flashing when the prewarn count (or time) is reached. When the Service Interval is in the background, it will come to the foreground when it reaches the service interval or the prewarn. Resetting the indicator resets the Service Interval to its specified setting and returns the Service Interval to the background.
The LED indicator and output will come on once the Redi-Alert is reached and stay on until reset.
The Model 57 family also offers the option of an additional display for those applications that require dual indications.
## **Features**
- Choice of single or dual displays
- Display counts/hours or both
- Factory programmed service alert
- Divide/multiply on inputs (factory set)
- With or without reset
- Output signal: none, relay or transistor
- Service indicator available
- DC input voltages
## **Options**
- Input scaling
- Count speed
- Reset type
- Indication of time/count
- Type of output
- One or two displays
- LED indication for service
- Maintenance Redi-Alert output
- IP 65 sealed front panel
- EEPROM for memory (no battery)
## **Specifications**
**Display:** Large 7 digit, 0.28 [7mm], LCD **Protection:** IP 65 front panel/gasket supplied 1 or 2 displays **EMC:** EN 55011,EN 50082-2 **Quartz Accuracy:** 0.01% over entire voltage & temp. range **Vibration:** 1g (10…500 Hz) IEC 68-2-34 **Input Voltage:** 12-24 VDC/ ±25% **Shock:** 30 g(18 msec.) IEC 68-2-27 24 VDC/ ±25% - with relay output 25 g(6 msec) IEC 68-2-29 **Special Voltages:** 24-48 VDC/ ±25% **Max Count Speed:** 30 or 200 Hz (specify) 12,36,48 VDC/ ±25%-with relay output **Memory:** EEPROM (no battery) **Current Consumption:** 12-24 VDC/<10 mA, 24-48 VDC/<10 mA **Mounting:** Metal clamp (12 V/< 35 mA, 24 V/< 25 mA, 36 V/<25 **Electrical Connection:** 8 pole compact plug with lock mA, 48 V/< 20 mA) with relay **Case Material:** Black, ABS plastic w/glass lens **Relay Contact:** 1 dry contact / breaking capacity **Reset:** Manual & remote (manual button on the 12 V/2 A, 24 V/2 A, 36 V/1.5 A, 48 V/1 A rear of housing), non-reset, remote **Transistor Output:** VOH 4.5 VDC, minimum through 30 KW **Service Alert:** Factory set - one Redi-Alert, 4 digits VOL 0.4 VDC, maximum through 20 KW **Prewarn Signal:** Factory set, 4 digits ISINK 1.0 mA, maximum **Input Scaling:** Factory set, 4 digits **Operating Temperature :** -22 °F to +158 °F [-30 °C to +70 °C] **Weight:** 3.5 oz [99g] **Approvals:** CE Compliant
**www.redingtoncounters.com**
**58**
am **Model 57**
**LCD Hour/Counter/Maintenance Meter**
**Electronic**
## **Models Description**
For Details on Models and Descriptions, see the Ordering Information section.
## **Dimensions**
**==> picture [315 x 296] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.30 [58.5]<br>0.31 [8.0] 1.68 [42.7]<br>MOUNTING CLIP Ø2.05 [52.0]<br>R 1 2 3 4 M<br>5 6 7 8<br>ow 28) [©]<br>Ø2.20 [56.0] aN Ø2.20 [56.0]<br>NO BY<br>Maximum Panel Thickness: 0.20” [5.1mm]<br>Panel Cutout: 2.06” [52.2mm]<br>**----- End of picture text -----**<br>
## **Wiring Diagram**
**==> picture [380 x 121] intentionally omitted <==**
**----- Start of picture text -----**<br>
relay output NPN Transistor output<br>+ 8 8 = operating voltage "+" + 8 5V 8 = operating voltage "+"<br>1 1 = Input display 1 1 1 = Input display 1<br>10k<br>So 2 2 = reset display 1 so 2 2 = reset display 1<br>3 3 = relay output "+" Out 3 3 = transistor output<br>20k<br>4 4 = relay output "-" 4 4 = not used<br>6 6 = Input display 2 6 6 = Input display 2<br>7 7 = reset display 2 7 7 = reset display 2<br>-<br>5 5 = operating voltage "-" - 5 5 = operating voltage "-"<br>**----- End of picture text -----**<br>
## **Applications**
Panel Builders
Medical Devices
Packaging Machinery
Test Equipment
**www.redingtoncounters.com**
**59**
Ae **Model 57**
**LCD Hour/Counter/Maintenance Meter**
**Electronic**
## **Ordering Information**
|**Ordering Informationg Information Information**<br>a|||**e**e<br>|ee|
|---|---|---|---|---|
|**Model No. **<br>a~~ee~~<br>a|**Voltage**<br>~~ee~~<br>|**Function**<br>~~ee~~<br>|**Reset**<br>~~ee~~<br>**e**e<br>|**Notes**<br>~~ee~~<br>ee|
|5700<br>a~~e~~<br>a|12 - 24 VDC<br>~~e~~<br>|HM*<br>~~e~~<br>|HM<br>**e**e<br>~~e~~<br>**e**e<br>|without output or LED<br>ee|
|5701<br>aee<br>a|12 - 24 VDC<br>ee<br>|C*<br>ee<br>|C<br>ee<br>**e**e<br>|without output or LED<br>ee|
|5702<br>a|12 - 24 VDC<br>e|HM with HM (bg)*<br>e|HM<br>**e**e<br>e|without output or LED|
|5703<br>aee<br>a|12 - 24 VDC<br>ee<br>ee|C with C (bg)*<br>ee<br>ee|C<br>ee<br>ee|without output or LED<br>ee|
|5704<br>a<br>a|12 - 24 VDC<br>ee<br>ee|HM with C (bg)*<br>ee<br>ee|BOTH<br>ee<br>ee|without output or LED<br>ee|
|5705<br>a<br>a<br>a|12 - 24 VDC<br>ee<br>ee<br>|C with HM (bg)*<br>ee <br>ee<br>ee<br>|BOTH<br> ee<br>ee<br>**e**e<br>|without output or LED<br>ee<br>ee|
|5706<br>a<br>ee<br>a<br>a|24 VDC<br>ee<br>ee<br><br>|HM with SHM (bg)*<br>ee<br>ee<br>ee<br><br>|SHM<br>ee<br>ee<br>**e**e<br>**e**e<br>|with relay output and LED<br>ee<br>ee<br>ee|
|5707<br>a<br>a|12 - 24 VDC<br>e<br>|HM with SHM (bg)*<br>ee <br>e<br>|SHM<br> **e**e<br>e**e**e<br>ee|with transistor output and LED<br>ee|
|5708<br><br>a<br>a|24 VDC<br><br>e<br>|C with SC (bg)*<br><br>e<br>ee<br>|SC<br>**e**e<br>eee<br>**e**e<br>|with relay output and LED<br>ee|
|5709<br><br>ee<br>a|12 - 24 VDC<br><br>ee<br>|C with SC (bg)*<br><br>ee<br>ee<br>|SC<br>ee<br>ee<br>**e**e<br>|with transistor output and LED<br>ee<br>ee|
|5710<br>ae|24 VDC<br>e|SHM with HM (bg)*<br>ee <br>e|SHM<br> **e**e<br>e|with relay output and LED<br>ee|
|5711<br>a|12 - 24 VDC<br>ee|SHM with HM (bg)*<br>ee|SHM<br>ee|with transistor output and LED<br>ee|
|5712<br>a|24 VDC|SC with C (bg)*|SC|with relay output and LED|
|5713<br>a|12 - 24 VDC|SC with C (bg)*|SC|with transistor output and LED|
_*HM= Hour Meter *C= Counter *bg= Background *SHM= Service Hour Meter *SC= Service Counter_
## **Model 57**
## **Specification Sheet**
Company: __________________________ Phone: ____________________ Address: __________________________ Fax: ____________________ __________________________ Email: ____________________ Contact: __________________________ Date: ____________________
**Model No. ___________** (4 digits) _SELECTED FROM ABOVE TABLE_
## **Display 1**
> **Display 2 (Optional)** O Yes O No
**Indication of time for Hour Meter:** _(check only 1)_ **Indication of time for Hour Meter:** ( _check only 1)_ ~~O~~ 1/100[th] ~~O~~ 1/10[th] 1/100[th] 1/10[th] **Max. counting frequency for Counter: (** _check only 1)_ **Max. counting frequency for Counter:** _(check only 1)_ ~~O~~ 30 Hz O 200 Hz Oo 30 Hz O 200 Hz **Reset types:** _(check only 1)_ **Reset types:** _(check only 1)_ ~~O~~ non-reset ~~O~~ remote reset non-reset remote reset ~~O~~ remote & manual (manual reset on rear of housing) O remote & manual (manual reset on rear of housing)
**Max. counting frequency for Counter: (** _check only 1)_ **Max. counting frequency for Counter:** _(check only 1)_ ~~O~~ 30 Hz O 200 Hz Oo 30 Hz O 200 Hz
**Service interval** _(optional)_ **Input scaling:** _(optional - check only 1)_ ~~OO~~ “Redi-Alert”: _____________ ( 4 digits max) Divider _______________ ( 4 digits max) ~~O~~ Prewarn: _____________ (4 digits max.) O Multiplier _______________ ( 4 digits max)
**Input scaling** _(optional - check only 1)_
O Divider _______________ ( 4 digits max) O Multiplier _______________ ( 4 digits max)
**www.redingtoncounters.com**
**60**
| | **Model 59**
**LCD Hour/Counter/Maintenance Meter**
**Electronic**
## **Description**
The Redington Model 59 line of LCD modules can easily be integrated into your equipment or machinery. These functions are also available in cased versions, ask for more information, or see Model 55, 56 & 57.
## **Single Indicator:**
Can be used to display hours or count.
## **Twin Indicator:**
These models can supply two indications in one display. You can decide which function should be indicated permanently and which one in the background. The background function displays for approximately 10 seconds every time you power-up the display. When using a counter and an hour meter in combination, the counter will count the number of input pulses while the hour meter will record the total duration of the input pulses. Presettable “prewarn” signals can also be programmed into the modules. If you specify a prewarn the display will flash when it reaches its specified value. A wide range of reset functions are also available to provide you with the exact configuration for your application. Model 57 is available with an output function to “alert” when service or preventive maintenance should occur.
## **Redi-Alert:**
The Redington Model 59 LCD Maintenance Meter modules can easily be integrated into your equipment or machinery. This module can display hours, counts or both with a single-line, shared display. You can decide which function should be indicated permanently and which one is in the background. The background function, value, appears for approximately 10 seconds every time you power-up the display. When using a hour meter and counter in combination, the counter will count the number of input pulses while the hour meter will record the total duration of the input pulses. A wide range of reset functions are available to provide you with the exact configuration for your application.
The Redi-Alert Service Interval feature notifies operators of service requirements when service intervals are a function of the number of events or time. If a Redi-Alert Service Interval is specified, the display will show the count (or time) remaining until the service interval is reached. The RediAlert Service Interval feature can be considered to be a down-counter (or down-timer) since the count (or time) that is displayed shows what remains until service is required. When the Redi-Alert Service Interval gets to zero, the indicator will flash the display. If the Redi-Alert Service Interval is not reset, the indicator will continue to operate, and the display will show negative counts (or time) indicating how far the system has gone past the service interval. If the prewarn feature is included, the display will begin flashing when the prewarn count (or time) is reached. When the Service Interval is in the background, it will come to the foreground when it reaches the service interval or the prewarn. Resetting the indicator resets the Service Interval to its specified setting and returns the Service Interval to the background. The LED indicator and output will come on once the Redi-Alert is reached and stay on until reset.
## **Features**
- Display time/count or both
- “Redi-Alert” function for service
- Choice of non-reset or remote reset
- EEPROM for memory (no battery)
- Divider/multiplier
## **Options**
- Input scaling
- **•** Input frequency **•** Remote reset
- Service “Redi-Alert”
- Display functions
- 30 or 200 Hz, max input frequency
- 1/10[th] or 1/100[th] hour indication
- 12 to 24 VDC power range
## **Specifications**
**Display:** 7 digit, 0.28 [7mm], LCD **Electrical Connection:** Pins for soldering **Quartz Accuracy:** 0.01% **Reset:** Non-reset, remote **Input Voltage:** 12-24 VDC/ ±25% **Protection: Current Consumption:** 2-4 mA **EMC:** EN 55011, EN 50082-2 **Transistor Output:** VOH 4.5 VDC, minimum through 30 KW **Vibration:** 1 g (10 to 500 Hz ) IEC 68-2-34 VOL 0.4 VDC, maximum through 20 KW **Shock:** 30 g (18 msec.) IEC 68-2-27 ISINK 1.0 mA, maximum 25 g (6 msec.) IEC 68-2-29 **Operating Temperature** : -22°F/+158°F [-30°C to +70°C] **Weight:** 0.5 oz [14g] **Max Count Speed:** 30 or 200 Hz **Service Alert:** 1 “Redi-Alert”, 4 digits, factory set **Memory:** EEPROM (no battery) **Input Scaling:** Factory set, 4 digits **Approvals:** UL/cUL Recognized **Prewarn Signal:** Factory set, 4 digits **Mounting:** Electrical connection pins for soldering
## **Models Description**
For Details on Models and Descriptions, see the Ordering Information section.
**www.redingtoncounters.com**
**61**
**LCD Hour/Counter/Maintenance Meter**
## am **Model 59**
## **Electronic**
## **Dimensions**
**==> picture [510 x 145] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.10 [27.9] Wiring Diagram<br>0.28 [7.1] 0.12 [3.05] NPN Transistor Output<br>0.12 [3.05]<br>— - i + a +<br>0.28 [7.0]<br>0.58 [14.7] 0.37 [9] 0.86 [21.8] 1.00 [25.4] C / Input<br>0.07 [1.7] 0.57 [14.6] 0.15 [3.8] MAX R 5V<br>PEEEET: C OUT R 0.24 [6.2] poe HEIGHT OFCOMPONENTS 10k<br>0.55 [13.9] bp por 0.07 [1.8] st tA OPTION = Ø0.06 [1.5] yG: |<br>1.48 [37.5] PIN: Out<br>1.65 [42.0] + = OPERATING VOLTAGE - = GND 20k<br> C = COUNT : [|]<br> OUT = SERVICE COUNTER OUTPUT (OPTION)ALTERNATINE POSITIONS OF THE CONNECTION PINS - |<br>pplicationslications ARE OPTIONALLY POSSIBLE.<br>Test Equipment Panel Builders Medical Devices Office Equipment Flow Meters<br>**----- End of picture text -----**<br>
## **Applicationslications**
## **Ordering Information**
~~a~~ Model# Function Output Signal Notes SINGLE FUNCTION a ~~ee~~ ee 5902 HM* - HM is resettable 5912 C* - C is resettable a ee ee TWO FUNCTION a ee 5922 HM with HM (bg)* - Only HM is resettable a ee ee a 5932 C with C (bg)* - Only C is resettable 5942 HM with C (bg)* - Both are resettable a Pp 5952 C with HM (bg)* - Both are resettable Pp 5962 HM with SHM (bg)* included Only SHM (bg) is resettable 5972 C with SC (bg)* included Only SC (bg) is resettable a I 5982 SHM with HM (bg)* included Only SHM is resettable 5992 SC with C (bg)* included Only SC is resettable a ee ee
- *HM=HOUR METER *C= COUNTER *bg=BACKGROUND *SC= SERVICE COUNTER *SHM= SERVICE HOUR METER
## **Model 59**
**Specification Sheet**
Company: __________________________ Phone: ____________________ Contact:Address: ______________________________________________________________________________ Email:Date:Fax: ____________________________________________________________
**Model No. ___________** (4 digits) _SELECTED FROM ABOVE TABLE ._
**Input voltage:** _(check only 1)_ O 12-24 VDC Special voltages available, consult factory. **Indication of time for Hour Meter:** _(check only 1)_ O 1/100[th] O 1/10[th] **Max. counting frequency for Counter:** _(check only 1)_ ~~OO~~ 30 Hz (DC) 200 Hz DC **Reset type:** _(check only 1)_ ~~O~~ non-reset O remote reset **Service interval:** _(optional)_ O “Redi-Alert” : ——— (4 digits max) O Prewarn : ——— (4 digits max) **Input scaling:** _(optional - check only 1)_ O Divider: —_____ ______________ ~~_~~ _ (4 digits max) oO Multiplier: ______________ (4 digits max)
**www.redingtoncounters.com**
**62**
| | **Model 94**
**LCD Hour Meter**
**Electronic**
## **Description**
A 6 figure, battery powered, push-button or key reset, electronic hour meter, available in base mount or panel mount configuration. No external power supply is required. Large 0.50’’ [12mm] LCD figures for fast, easy reading. Operates at 6-240 VAC or VDC. Long lasting internal lithium battery. Attractive styling and silent operation make these models equally well-suited for lab or office equipment applications.
## **Features**
- No external power supply needed
- • Long life lithium battery
- Large easy reading display
- Operates at 6 to 240 VAC or VDC
## **Options**
- Non-reset
- Remote reset
- Minutes meter
- Seconds meter
## **Specifications**
**Figures:** 6 LCD figures, 0.50’’ [12mm] high **Reset:** Push-button, or lock and key **Input:** 6-240VAC (50/60Hz) or 6-240VDC Vih 6VAC/VDC minimum Vil 2VAC/VDC maximum **Mounting:** Base or panel
**Terminations:** (2) #22 AWG 221°F [105° C] wire leads, 8’’ [203mm] long **Temp. Range:** -14°F to +122°F [-26°C to +50°C] **Power Source:** Internal lithium battery **Weight:** 18 oz. [510g]
Note: When interfacing the Model 94 with a Solid State Relay or AC Sensor, the leakage current needs to be considered. Contact the factory or see the application note at www.redingtoncounters.com for further information.
## **Models Description**
**9425-001** 6 figure, base mount, push-button reset **9425-003** 6 figure, panel mount, push-button reset **9425-005** 6 figure, panel mount, lock and key reset
* Items are normally in factory stock.
## **Dimensions**
**==> picture [502 x 109] intentionally omitted <==**
**----- Start of picture text -----**<br>
Base Mount Panel Mount<br>3.81 [96.8] 4.44 [112.7]<br>2.97 [75.3]<br>3.15 [80.0] 3.15 [80.0] 2.90 [73.5]<br>re Ss Ff ee ee<br>1.65 [41.9]<br>1.36 [34.4] 1.65 [41.9] 1.75 [44.4] 1.50 [38.1] 1.87 [47.6] 1.41 [35.8]<br>ie eo<br>0.88 [22.2] it 3.23 [82.0] op} j _I 1, 4.06 [103.2] oI J yl a<br>—— 3.31 [84.1] ~~<br>Mounting holes: 0.14’’ x 0.24’’ [3.6mm x 6.1mm] slots Panel cutout: 3.0’’ x 1.75” [76.2mm x 44.5mm]<br>Mounting holes: 0.17’’ [4.3mm] Dia.<br>**----- End of picture text -----**<br>
## **Panel Mount/Lock & Key Reset**
**==> picture [54 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
Applications<br>**----- End of picture text -----**<br>
**==> picture [250 x 89] intentionally omitted <==**
**----- Start of picture text -----**<br>
5.50 [139.7]<br>3.15 [80.0] 2.90 [73.5]<br>Pa OC re<br>1.75 [44.5] Te f= y] 1.65 [41.9] oT T 1.41 [35.8]<br>LI. Job 2.12 [54.0] =<br>5.13 [130.2]<br>—- —__|<br>Panel cutout: 4.75 ’’ x 1.50” [76.2mm x 44.5mm]<br>Mounting holes: 0.17’’ [4.3mm] Dia.<br>**----- End of picture text -----**<br>
**==> picture [377 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Office equipment Production Test labs Control panels<br>**----- End of picture text -----**<br>
**www.redingtoncounters.com**
**63**
rt **Model 720**
**LCD Hour Meter**
**Electronic**
## **Description**
The Redington Model 720 Electronic Hour Meter offers a large 7 digit LCD display, (999999.9) 0.32" (8mm) high, with an input operating voltage of 85-500VAC. The front of the unit is totally sealed, and the Hour Meter is housed in a rugged steel enclosure that is interchangeable with the Redington Model 720 Electro Mechanical Hour Meters. The wide operating voltage makes this product ideal for almost any application.
## **Features**
- Operating voltage 85-500VAC
- Rugged steel housing
- Lithium battery
## **Options**
- Gasket (721-0004)
- Special termination available
- DC
- Quartz accuracy (better than 0.01%)
- Popular 3-hole mounting
## **Specifications**
**Display:** Large 7 digit LCD (999999.9), 0.32" [8mm] high **Reset:** Non-reset **Voltage:** 85-500VAC 50/60Hz **Hour Meter Memory:** Self-powered (internal lithium battery) **Termination:** Wire leads 6" [152mm] **Mounting:** Panel (3-Hole) **Temp. Range: Operating:** -4°F to + 140°F(-20°C to +60°C) **Storage:** -40°F to +165°F (-40°C to +75°C)
**Humidity:** 0 to 95% RH, non-condensing, front totally sealed **Vibration:** 10 to 80 Hz, 0.06 double amplitude **Shock:** 50G **Dielectric:** 1000VAC 50/60Hz for 1 minute **Accuracy:** Quartz accuracy (better than 0.01%) **Weight:** 5.0 oz (142g)
## **Models Description**
**720-5300** 85-500VAC, non-reset, 3-hole round, 6" (152mm) wire leads
- Item is normally in factory stock.
## **Dimensions**
## **720-5300**
**==> picture [227 x 169] intentionally omitted <==**
**----- Start of picture text -----**<br>
3X Ø.125 [Ø3.2] EQUALLY SPACED<br>ON A 2.44[62.0] B.C.<br>ER Ø2.14 [54.2]<br>EREEEE<br>6 IN. LEADS<br>Ø2.66 [67.5] | 2.37 [60.2]<br>Panel cutout: 2.16’’ [54.9] Dia.<br>Mounting holes: 0.125’’ [3.2] Dia. on 2.44’’ [62.0] B.C.<br>**----- End of picture text -----**<br>
## **Applications**
**==> picture [365 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
Control panels Outdoor Lighting Industrial Equipment Compressors<br>**----- End of picture text -----**<br>
**==> picture [54 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Test equipment<br>**----- End of picture text -----**<br>
**www.redingtoncounters.com**
**64**
| | **Model 77**
**Electromechanical**
**Hour Meter**
## **Description**
The Model 77 is a compact, non-reset, 6 figure, 99999.9, electromechanical hour meter. Available with several mounting styles, panel, behind the panel and “snap-in” mount. Products are UL Recognized, CSA Certified and CE Compliant.
|**Features**|**Features**|**Options**||
|---|---|---|---|
|•|Panel or snap-in mount|•|Voltage|
|•|Compact size|•|Frequency|
|•|Non-reset|•|Mounting|
## **Features**
## **Specifications**
|**Figures:**|6 figures, 0.11’’ [3mm] high|**Mounting:**||Panel (front, behind, or snap-in)|
|---|---|---|---|---|
||99,999.9 hours|**Termination:**||Screw type, round terminals|
|**Reset:**|Non-reset|**Temp. Range:**||-60°F to +154°F [-51°C to +68°C]|
|**Voltages:**|115VAC, (+/- 10%) 60Hz.|**Approvals:**||UL Recognized, CSA Certified, CE Compliant|
|**Power:**|3 watts (nominal)|**Weight:**||2.5 oz. [71g]|
|**Models**|**Description**|**Models**|**Description**||
|P2-7717/60|115VAC/60Hz, non-reset, panel mount|SR2-7717/60|115VAC/60Hz, non-reset, snap-in mount||
|R2-7717/60|115VAC/60Hz, non-reset, behind the panel mount||||
## **Dimensions**
## **SR-7717**
**==> picture [452 x 146] intentionally omitted <==**
**----- Start of picture text -----**<br>
P-7717 SR-7717<br>2.11 [53.6]<br>1.80 [45.8] 1.80 [45.8] 2.07 [52.6]<br>0.14 [3.6]<br>1.40 [35.5] 1 2 3 4 5 6 1.80 [45.6] 1 2 3 4 5 6 1.44 [36.5]<br>[id [|<br>Panel cutout: 1.72’’ x 1.05’’ [43.7 x 26.7]<br>Panel cutout: 1.68’’ x 1.31’’ [42.7 x 33.3]<br>Mounting holes: For #5 flat head screw<br>**----- End of picture text -----**<br>
## **Applications**
**==> picture [54 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Test equipment<br>**----- End of picture text -----**<br>
**==> picture [51 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Control panels<br>**----- End of picture text -----**<br>
**==> picture [58 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
Office machines<br>**----- End of picture text -----**<br>
**==> picture [71 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Industrial equipment<br>**----- End of picture text -----**<br>
**www.redingtoncounters.com**
**65**
| | **Model 710**
**Electromechanical**
**Hour Meter**
## **Description**
The model 710 AC hour meters and minute meters are widely used in panel applications where number size and visibility are critical. Its tough, Lexan bezel and distinctive styling enhance appearance and durability. Available in 5 figure reset or 6 figure non-reset versions.
## **Features**
- Large figures
- Tough, Lexan case
- Reset or non-reset
## **Specifications**
**Figures:** 5 figures, 9999.9 (reset) or 6 figure, 99999.9 (non-reset), 0.19’’ [5mm] high **Reset:** Reset (on front or side) or non-reset **Voltages:** 24, 115 or 230VAC, (+/-10%), 50 or 60 Hz. **Power:** 3 watts (nominal) **Mounting:** Panel (3-hole) **Models Description**
**710-0001** 115VAC/60Hz, non-reset, 99,999.9 hrs, 8’’ [203mm] wire leads **710-0002** 115VAC/60Hz, non-reset, 99,999.9 hrs, terminal block **710-0003** 230VAC/60Hz, non-reset, 99,999.9 hrs, 8’’ [203mm] wire leads **710-0006** 24VAC/60Hz, non-reset, 99,999.9 hrs, 8’’ [203mm] wire leads 710-0008 115VAC/60Hz, non-reset, 99,999 hrs, 8’’ [203mm] wire leads **710-0009** 115VAC/50Hz, non-reset, 99,999.9 hrs, 8’’ [203mm] wire leads **710-0013** 115VAC/60Hz, front reset, 9,999.9 hrs, 8’’ [203mm] wire leads
## **Options**
- Private label faceplates
- • Bracket mount • Mounting bracet (721-0003) • Splash proof kit (721-0017) • Heavy duty splash proof kit (721-0018) • Gasket (721-0004)
**Terminations:** 8’’ [203.2mm] wire leads or terminal block **Temp. Range:** -20°F to +160°F [-29°C to +71°C] **Approvals:** UL Recognized, CSA Certified, CE Compliant **Weight:** 6 oz. [170g]
**Models Description 710-0014** 230VAC/60Hz, non-reset, 99,999.9 hrs, terminal block 710-0018 115VAC/60Hz, non-reset, 99,999.9 min, 8’’ [203mm] wire leads 710-0024 24VAC/60Hz, non-reset, 99,999.9 hrs, terminal block **710-0026** 115VAC/50Hz, non-reset, 99,999.9 hrs, terminal block **710-0032** 115VAC/60Hz, front reset, 9,999.9 hrs, terminal block 710-0051 115VAC/60Hz, non-reset, 99,999 hrs, terminal block
* Items in bold are normally in factory stock.
## **Dimensions**
## **8” [203mm] Wire Leads**
**==> picture [486 x 164] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.40 [61.0]<br>1 2 3 4 5 6 2.84 [72.1] 2.18 [55.2]DIA<br>0.19 [4.8] ~ 1.98 [50.3] -<br>Mounting holes: For #4 screws on 2.44” [62.0] B.C.<br>and #6 screws on 2.53” [64.3] B.C.<br>Panel cutout: 2.21’’ [56.1] Dia.<br>lications<br>Office equipment Control panels Industrial equipment Test equipment Compressors<br>**----- End of picture text -----**<br>
## **Applications**
**www.redingtoncounters.com**
**66**
**Model 711/731**
**Electromechanical**
**Hour Meter**
## **Description**
The Redington Model 711/731 provides a family of compact 7 figure, AC or DC Hour Meters. Models are available in the standard industry housings, 2-Hole rectangular, flush-round and flush-rectangular. DC Models are quartz controlled for high reliability and accuracy. A choice of two rectangular panel cutouts are offered 1.45" X 0.95’’ [36.8mm X 24.1mm] or 1.45" X 0.87" [36.8mm X 2.1mm]. The Round meter has a panel cutout of 1.99" [50.5mm].
## **Features**
- 7 figure, 99999.99
- Various voltage inputs
- Quartz accuracy (DC)
## **Options**
- Special voltages
- **•** Terminations
- Panel cutout
- Large figures, 0.14" [3.6mm]
- CE Compliant
- UL Recognized/CSA Certified for AC
- UL/cUL Recognized for DC
## **Specifications**
**Figures:** 7 figures, 0.14" [3.6mm] 99999.99 **Environmental: Reset:** Non-reset **Front Panel:** IP65 **Voltages:** 24, 115 or 230VAC (± 10%), 50 or 60 Hz 10-28VDC **Operating Temperature:** -40°F to +180°F [-40°C to +82°C] **Power:** 2 watts AC, 0.4 watts DC **Storage Temperature:** -40°F to +185°F [-40°C to +85°C] **Mounting:** Clip or mounting holes **Humidity:** 95% RH- SAE J 1378 **Termination:** 1/4” [6.3mm] spade terminals with screws (AC) **Vibration:** 20g’s @ 10-80 Hz- SAE J 1378 1/4” [6.3mm] spade terminals (DC) **Shock:** 55g’s @ 9-13 msec.- SAE J 1378 **Accuracy:** 0.01% (DC) quartz **Transient Immunity:** EMI: ± 400V@ 500Hz **Case Material:** Black polymer **Alternator Load Dump:** 150V inductive switching, reverse **Agency Approvals:** CE Compliant polarity and over voltage protection UL Recognized/CSA Certified for AC UL/cUL Recognized for DC **Weight:** 1.2oz. [35g] **Models Models Voltage Mount Panel Cut-out Models Voltage Mount Panel Cut-out AC 1.45 X .87 1.45 X .95 1.99 DC 1.45 X .87 1.45 X .95 1.99** 711-0013 115VAC/60Hz Round X 731-0006 10-28VDC Round X 711-0014 230VAC/60Hz Round X **731-0040** 10-28VDC 2-Hole X 711-0015 24VAC/60Hz Round X 731-0041 10-28VDC Flush Rect X **711-0113** 115VAC/60Hz Flush Rect X 731-0042 10-28VDC Flush Rect X **711-0114** 24VAC/60Hz Flush Rect. X 731-0051 10-28VDC 2-Hole X 711-0120 115VAC/60Hz Flush Rect X 711-0123 711-0124 24VAC/60Hz230VAC/60Hz Flush Rect.Flush Rect. XX * Items in bold are normally in factory stock. **711-0130** 115VAC/60Hz 2-Hole X 711-0131 230VAC/60Hz 2-Hole X 711-0132 24VAC/60Hz 2-Hole X 711-0133 115VAC/50Hz 2-Hole X 711-0134 230VAC/50Hz 2-Hole X 711-0138 230VAC/60Hz Flush Rect. X 711-0215 115VAC/60Hz 2-Hole X 711-0216 230VAC/60Hz 2-Hole X 711-0217 24VAC/60Hz 2-Hole X F]]]JER2 **www.redingtoncounters.com 67**
**Model 711/731**
**Electromechanical**
**Hour Meter**
## **Dimensions**
**==> picture [494 x 527] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.75 [44.5]<br>1.4 [36]<br>1 2 3 4 5 6 7<br>S| 1.08 [27.4] | (an<br>2X Ø.16 [Ø4.1]<br>0.9 1 2 3 4 5 6 7<br>[23] 1.21 [30.8]<br>1.60 [40.6] 0.87 [22.0]<br>1.43 [36.2] 0.12 [2.9] 2.1 [53] 0.87 [22.0]<br>: r— T 1.43 [36.2] J 0.08 [2.2] Lt<br>TTT TE [Oy]<br>0.06 [1.4]<br>2.33 [59.2] 2.33 [59.3]<br>PANEL OPENING 1.45 [36.8] X 0.87 [22.1]<br>PANEL OPENING 1.45 [36.8] X 0.87 [22.1]<br>PANELTHICKNESS 0.50'' [12.7]<br>_ |<br>PANEL OPENING 1.99 [50.5] DIA<br>1.75 [44.5]<br>. 1.4 [36] “ym<br>1 2 3 4 5 6 7<br>2X Ø.16 [Ø4.1] 1.08 [27.4]<br>[23]0.9 1 2 3 4 5 6 7 1.21 [30.8]<br>1.60 [40.6] 0.93 [23.5]<br>2.1 [53] 0.93 [23.5] 1.43 [36.2] 0.12 [3.0]<br>1.43 [36.2]<br>0.06 [1.4]<br>et s fo 4 r rt io<br>0.08 [2.2]<br>2.33 [59.3]<br>2.33 [59.2]<br>PANEL OPENING 1.45 [36.8] X 0.95 [24.1] Ld<br>PANEL OPENING 1.45 [36.8] X 0.95 [24.1]<br>PANELTHICKNESS 0.50'' [12.7]<br>O2.28 [O58]<br>0.13 [3.3]<br>2.33 [59.3]<br>1 2 3 4 5 6 7<br>H O U R S<br>**----- End of picture text -----**<br>
## **Applications**
**==> picture [66 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
Medical equipment<br>**----- End of picture text -----**<br>
**==> picture [54 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
Test equipment<br>**----- End of picture text -----**<br>
**==> picture [60 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
Office equipment<br>**----- End of picture text -----**<br>
**www.redingtoncounters.com**
**68**
**Model 711/731**
**Electromechanical**
**Hour Meter**
## **Description**
These 7 figure, AC or DC hour meters with running indicators, offer crisp, distinctive styling for many panel applications. Available in square and round bezel, flush mount, or three-hole round panel mount. Each is light-weight, low power, and carry UL, CSA and CE approvals.
## **Options**
## **Features**
- 7 figure, 99999.99 • Terminations
- **•** Various voltage inputs • Din rail • Distinctive styling • Voltages 7 figures, 0.14’’ high [3.6mm], 99,999.99 hours **Mounting:** Panel (mounting hardware included) Non-reset **Temp. Range:** -22°F to +158°F [-30°C to +70°C] 24, 115, or 230VAC (+/-10%), 50 or 60Hz., 10-80 VDC **Approvals:** UL Recognized and CSA Certified (AC only), 3 watts (AC), 1.2 watt maximum (DC) CE Approved 1/4’’ [6.3mm] spade terminals, with removable screws, **Weight:** 2 oz. [57g]
## **Specifications**
**Figures:** 7 figures, 0.14’’ high [3.6mm], 99,999.99 hours **Reset:** Non-reset **V** oltages: 24, 115, or 230VAC (+/-10%), 50 or 60Hz., 10-80 VDC Power: 3 watts (AC), 1.2 watt maximum (DC) **Terminations:** 1/4’’ [6.3mm] spade terminals, with removable screws, or 8’’ [203mm] wire leads
## **Models Description**
**711-0150** 115VAC/60Hz, 2.28’’ Dia.,Flush mount, screw termination 711-0152 230VAC/60Hz, 2.28’’ Dia.,Flush mount, screw termination **711-0160** 115VAC/60Hz, 2.93’’ Dia.,3-hole round, screw termination 711-0161 115VAC/50Hz, 2.93’’ Dia.,3-hole round, screw termination 711-0162 230VAC/60Hz, 2.93’’ Dia.,3-hole round, screw termination 711-0163 230VAC/50Hz, 2.93’’ Dia.,3-hole round, screw termination 711-0164 24VAC/60Hz, 2.93’’ Dia.,3-hole round, screw termination 711-0170 230VAC/60Hz, 2.93’’ Dia.,3-hole round, 8’’ wire leads 711-0171 115VAC/60Hz, 2.93’’ Dia.,3-hole round, 8’’ wire leads **711-0180** 115VAC/60Hz, 1.89’’ Sq., Flush mount, screw termination
## **Models Description**
711-0182 24VAC/60Hz, 1.89’’ Sq., Flush mount, screw termination **711-0190** 115VAC/60Hz, 2.05’’ Sq., Flush mount, screw termination 711-0191 230VAC/60Hz, 2.05’’ Sq., Flush mount, screw termination 711-0192 24VAC/60Hz, 2.05’’ Sq., Flush mount, screw termination 711-0193 115VAC/50Hz, 2.05’’ Sq., Flush mount, screw termination 711-0194 230VAC/50Hz, 2.05’’ Sq., Flush mount, screw termination 711-0195 24VAC/50Hz, 2.05’’ Sq., Flush mount, screw termination **731-0046** 10-80VDC, 2.93’’ Dia.,3-hole round, screw termination
* Items in bold are normally in factory stock.
## **Dimensions**
**==> picture [94 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.89’’ or 2.05’’ Square<br>**----- End of picture text -----**<br>
**==> picture [497 x 155] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.28’’ Dia. Flush 3 - Hole Round 1.89’’ or 2.05’’ Square<br>1.55 [39.3] 1.60 [40.6]<br>1.35 [34.3] 1.35 [34.3]<br>1.35 [34.3] 2.20 [55.9]<br>0.20 [5.1]<br>1 f ~ +t teraeat ft<br>1.77 [44.9] SS 1.77 [44.9] | 2.20 [55.9] [ea 1.77 [44.9]<br>—ey, 2.28 [57.9] El| Of 2.93 [74.5] | SIE<br>Panel cutout: 1.99’’ [50] Dia. or 1.81’’ [46] Sq. Panel cutout: 1.99’’ [50] Dia. or 1.81’’ [46] Sq. Panel cutout: 1.99’’ [50] Dia. or 1.81’’ [46] Sq.<br>Screws provided: 4-40 x 5/8’’ [16]<br>(for 1.89’’ Sq. use 1.81’’ [46] Sq. cutout only)<br>Applications Bolt hole circle: 2.44’’ [62]<br>Medical equipment Test equipment Office equipment<br>**----- End of picture text -----**<br>
**www.redingtoncounters.com**
**69**
**Model 711**
**Electromechanical**
**Hour Meter**
## **Description**
A rectangular style AC hour meter designed to complement existing meters in control panels. Available in 6 figure reset or 7 figure non-reset. The nonreset model incorporates a retaining clip to lock into panel, while the reset version has a metal bracket and screw.
## **Features**
- Large figures
## **Options**
- Reset or non-reset
- 6 or 7 digits
- UL Recognized, CSA Certified, CE Compliant
## **Specifications**
**Figures:** 6 figure (reset) or 7 figure (non-reset), 0.19’’ [5mm] high 9,999.99 hours. (reset version) 99,999.99 hours. (non-reset models) **Reset:** Push-button, or non-reset **Voltages:** 115VAC (+/- 10%), 50 or 60 Hz. **Power:** 2 watts (nominal)
**Mounting:** Panel (mounting hardware included) **Termination:** 19’’ [483mm] wire leads **Temp. Range:** -4°F to +158°F [-20°C to +70°C] **Approvals:** UL Recognized, CSA Certified, CE Compliant **Weight:** 2 oz. [57g] **Options:** Voltages
## **Models Description**
**==> picture [491 x 210] intentionally omitted <==**
**----- Start of picture text -----**<br>
711-0019 115VAC/60Hz, reset, 6 figure, 9,999.99 hrs., 19’’ [483mm] wire leads<br>711-0020 115VAC/60Hz, non-reset, 7 figure, 99,999.99 hrs., 19’’ [483mm] wire leads<br>711-0041 115VAC/50Hz, non-reset, 7 figure, 99,999.99 hrs., 19’’ [483mm] wire leads<br>Dimensions<br>Non-Reset Reset<br>0.19 [4.8]<br>1 2 3 4 5 6 7 1.14 [29.0] 0.98 [24.9] 1 2 3 4 5 6<br>1.14 [29.0] 0.98 [24.9]<br>=_t (AIFot eccoa b- ye<br>2.13 [54.0] 0.12 [3.0] 1.77 [45.0] 2.13 [54.1] 0.18 [4.4] 2.95 [74.9]<br>ae | es ee<br>Panel cutout: 1.98’’ x 0.99’’ [50.3 x 25.1] Panel cutout: 1.98’’ x 0.99’’ [50.3 x 25.1]<br>**----- End of picture text -----**<br>
**==> picture [54 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
Applications<br>**----- End of picture text -----**<br>
**==> picture [223 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Medical equipment Test equipment<br>**----- End of picture text -----**<br>
**==> picture [60 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Office equipment<br>**----- End of picture text -----**<br>
**www.redingtoncounters.com**
**70**
|[|] **Model 720**
**Hour Meter**
**Electromechanical**
## **Description**
A 5 figure (reset) or 6 figure (non-reset), AC hour meter encased in a rugged steel housing and designed to mil-spec environmental requirements. The non-reset models are completely sealed, and meet NEMA 4 standards. Reset models are available, as are both wire lead and terminal block versions.
|**Features**|**Features**||**Options**||
|---|---|---|---|---|
|•|Rugged steel housing||•|Chrome bezel|
|•|Mil-spec||•|Readouts to 9999.99 hrs.|
||||•|Minute meter|
||||•|Voltages|
|**Specifications**|||•|Gasket (721-0004)|
|**Figures:**||5 figure (reset) or 6 figure (non-reset), 0.19’’ [5mm]|**Mounting:**<br>Panel (3-hole or metal clamp)||
|||high, 9,999.9 (reset) or 99,999.9 (non-reset)|**Termination:**<br>Terminal block or 6’’ [152mm] wire leads||
|**Reset:**||Reset or non-reset|**Temp. Range:**<br>-65°F to +155°F [-54°C to +68°C]||
|**Voltages:**||24, 115, and 230VAC (+/- 10%), 50 or 60Hz.|**Approvals:**<br>UL Recognized, CSA Certified, CE Compliant||
|**Power:**||2.5 watts (nominal)|**Weight:**|10 oz. [284g]|
|**Models**||**Description**|**Models**|**Description**|
|**720-0001**||24VAC/60Hz,<br>non-reset, 3-hole round, 6’’ [152.4mm] wire leads|**720-0011**|115VAC/60Hz, non-reset, metal clamp, 6’’ [152.4mm] wire leads|
|720-0003||115VAC/60Hz, M3971/2-1 and M3971/2-5|720-0012|115VAC/60Hz, front reset, 3-hole round, 6’’ [152.4mm] wire leads|
|**720-0004**||115VAC/60Hz, non-reset, 3-hole round, terminal block|720-0030|115VAC/50Hz, non-reset, 3-hole round, 6’’ [152.4mm] wire leads|
|**720-0007**||115VAC/60Hz, non-reset, 3-hole round, 6’’ [152.4mm] wire leads|720-0031|230VAC/60Hz, non-reset, 3-hole round, terminal block|
|**720-0008**||115VAC/60Hz, non-reset, metal clamp, terminal block|720-0036|230VAC/60Hz, non-reset, 3-hole round, 6’’ [152.4mm] wire leads|
* Items in bold are normally in factory stock.
## **Dimensions**
## **Non-Reset / Terminal Block**
**==> picture [232 x 150] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.66 [67.6] DIA 2.44 [62.0]<br>\ \<br>2.14 [54.4]<br>1 2 3 4 5 6 DIA<br>3.23 [82.0]<br>Panel cutout: 2.16’’ [54.9] Dia.<br>Mounting holes: 0.125’’ [3.2] Dia. on 2.44’’ [62.0] B.C.<br>**----- End of picture text -----**<br>
## **Applications**
**==> picture [51 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Control panels<br>**----- End of picture text -----**<br>
**==> picture [231 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Industrial equipment Test equipment<br>**----- End of picture text -----**<br>
**www.redingtoncounters.com**
**71**
**Totally Sealed Hour Meter**
**Model 722**
## **Electromechanical**
## **Description**
The Redington Model 722 provides an AC Hour Meter with an operating range of 90-240VAC (± 10%) 50/60 Hz. You no longer require two separate meters, one for 115VAC and one for 230VAC. Models are available in the standard industry housings, 2-Hole Rectangular, FlushRectangular, Flush-Round and 3-Hole Round. Models 722-0001 and 722-0002 fit a panel opening of 1.45" X 0.95" [36.8mm X 24.1mm]. The Flush-Round Model 722-0003 and 3-Hole Model 722-0004 have a panel opening of 2.0" [50.6mm]. The Model 722 quartz time base insures accurate long-term time keeping. The Totally Sealed case protects against the environment and provides years of reliable service. Model 7220004, 3-Hole mount, is NEMA 4X,12 rated when mounted with optional gasket.
## **Features Options**
- Operating voltage 90-240VAC 50/60Hz
- Totally sealed
- UL/CSA Recognized, CE Compliant
- Wire leads
- 3-hole mount gasket kit (part# 5003-007S) (for NEMA 4X, 12 rating)
- 6 Figure, 99999.9
- Quartz accuracy
## **Specifications**
**Figures:** 6 - digits, 0.125" [3.2mm] 99999.9 **Accuracy:** ± 0.02 over entire range Hours - white on black **Case Material:** Black polymer Tenths - red on white **Agency Approvals:** UL/CSA Recognized, CE Compliant **Reset:** Non-reset **Environmental:** Totally sealed (all models) **Voltage:** 90-240VAC (± 10%) **Front Panel:** Model: 722-0004, NEMA 4X, 12 rated **Frequency:** 50/60Hz with optional gasket (part# 5003-007S) **Power:** Less than 0.6 watts **Temperature:** -40°F to +185°F [-40°C to + 85°C] **Mounting:** Clip or mounting holes **Vibration:** 10-75 Hz @ 1 to 8g’s **Termination:** ¼” [6.3mm] spade terminals **Weight:** 2 oz [57 g]
**Models Description 722-0001** 2-Hole Rectangular, 90-240VAC 50/60Hz, ¼” [6.3mm] spade terminals, hours & 1/10’s **722-0002** Flush-Rectangular, 90-240VAC 50/60Hz, ¼” [6.3mm] spade terminals, hours & 1/10’s **722-0003** Flush-Round, 90-240VAC 50/60Hz, ¼” [6.3mm] spade terminals, hours & 1/10’s **722-0004** 3-Hole Round, 90-240VAC 50/60Hz, ¼” [6.3mm] spade terminals, hours & 1/10’s **5003-007S** NEMA 4X, 12 Gasket kit and hardware for 3-Hole Round model (722-0004)
* All items are normally in factory stock
**www.redingtoncounters.com**
**72**
**Totally Sealed Hour Meter**
**Model 722**
**Electromechanical**
## **Dimensions**
**==> picture [490 x 239] intentionally omitted <==**
**----- Start of picture text -----**<br>
2-Hole Flush-Rectangular<br>1.43<br>[36.3] 1.43<br>0.69 [36.3]<br>[17.5] 0.69<br>[17.5]<br>[i]<br>MOUNTING<br>2.82 unk rt [i] CLIP<br>[71.6] 2.15 2.82<br>[54.6] [71.6] 2.15<br>[54.6]<br>0.03 TO 0.63<br>0.19[4.8] 0.06[1.5] 2.12 [53.8][35.8]1.41 2X Ø.15 [Ø3.8] 0.19 0.06[1.5] [35.8]1.41 PANEL THICKNESS[0.76 TO 16.00]<br>[4.8]<br>0 0 0 0 0<br>ho [31.7]1.25 0 0 0 0 00 0 0 0 0 0 [23.4]0.92 [23.4]0.92 we [31.7]1.25 0 0 0 0 00 0 0 0 0 0 [23.1]0.91 [23.4]0.92<br>[44.4]1.75 1/4" [6.3] TERMINAL [45.0]1.77 1/4" [6.3] TERMINALS<br>ey ; —_ eg<br>Panel Opening: 1.45" X 0.95" [36.8 X 24.1] Panel Opening: 1.45" X 0.95" [36.8 X 24.1]<br>Panel Thickness: 0.03 to 0.63 [0.76 to 16.00]<br>**----- End of picture text -----**<br>
**==> picture [234 x 241] intentionally omitted <==**
**----- Start of picture text -----**<br>
Flush-Round<br>1.69 [43.0]<br>1.53 [38.9]<br>0.40 [10.2] MAX<br>PANEL THICKNESS<br>MOUNTING<br>CLIP<br>1/4" [6.3] TERMINAL<br>Ø2.33<br>[59.2] 0 0 0 0 00 0 0 0 0 0 Ø1.99 [50.5] 0.69 [17.5]<br>0.22 [5.6]<br>1.50 [38.1]<br>0.49 [12.5]<br>Panel Opening: 2.0" [50.6]<br>Panel Thickness: 0.40 [10.2] Max.<br>**----- End of picture text -----**<br>
## **3-Hole Round**
**==> picture [231 x 167] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.69 [43.0]<br>3X Ø.15 [Ø3.8]<br>3X Ø.13 [Ø3.3] Ø2.54 [Ø64.5] 1.53 [38.9]<br>Ø2.44 [Ø62.0]<br>1/4" [6.3] TERMINAL<br>Ø2.80 Ø1.99<br>[71.1] 0 0 0 0 00 0 0 0 0 0 [50.5] 0.69 [17.5]<br>0.22 [5.6]<br>3X 120˚ 1.50 [38.1]<br>0.49 [12.5]<br>**----- End of picture text -----**<br>
Panel Opening: 2.0" [50.6]
## **Applications**
**==> picture [63 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Medical Equipment<br>**----- End of picture text -----**<br>
**==> picture [53 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Test Equipment<br>**----- End of picture text -----**<br>
**==> picture [58 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Office Equipment<br>**----- End of picture text -----**<br>
**www.redingtoncounters.com**
**73**
**Totally Sealed Hour Meter**
**Model 732**
## **Electromechanical**
## **Description**
The Redington Model 732 provides a DC Hour Meter with an operating range of 10-80VDC. Models are available in the standard industry housings, 3-Hole Round, Flush-Rectangular, Flush-Round and 2-Hole Rectangular. Models 732-0002 and 732-0004 fit a panel opening of 1.45" X 0.95" [36.8mm X 24.1mm]. The Flush-Round Model 732-0003 and 3-Hole Model 732-0001 fit a panel opening of 2.0" [50.6mm]. Its quartz time base insures accurate long-term time keeping. The Totally Sealed case protects against the environment and provides years of reliable service. The 3-Hole Round housing is NEMA 4X,12 rated when mounted with optional gasket.
- **Features Options •** Operating voltage 10-80VDC • Wire leads **•** Totally sealed • 3-hole mount gasket kit (part# 5003-007S) **•** UL/CSA Recognized, CE Compliant (for NEMA 4X, 12 rating) **•** 6 Figure, 99999.9 **•** Quartz accuracy
## **Specifications**
**Figures:** 6 - digits, 0.125" [3.2mm] 99999.9 **Accuracy:** ± 0.02 over entire range Hours - white on black **Case Material:** Black polymer Tenths - red on white **Agency Approvals:** UL/CSA Recognized, CE Compliant **Reset:** Non-reset **Environmental:** Totally sealed (all models) **Voltage:** 10-80VDC **Front Panel:** Model: 732-0001, NEMA 4X, 12 rated **Power:** 0.3 watts @ 12VDC with optional gasket (part# 5003-007S) **Mounting:** Clip or mounting holes **Temperature:** -40°F to +185°F [-40°C to + 85°C] **Termination:** ¼” [6.3mm] spade terminals **Vibration:** 10-75 Hz @ 1 to 8g’s **Weight:** 2.0 oz [57 g]
**Models Description 732-0001** 3-Hole Round, 10-80VDC, ¼” [6.3mm] spade terminals, hours & 1/10’s **732-0002** Flush-Rectangular, 10-80VDC, ¼” [6.3mm] spade terminals, hours & 1/10’s **732-0003** Flush-Round, 10-80VDC, ¼” [6.3mm] spade terminals, hours & 1/10’s **732-0004** 2-Hole Rectangular, 10-80VDC, ¼” [6.3mm] spade terminals, hours & 1/10’s **5003-007S** NEMA 4X, 12 Gasket kit and hardware for 3-Hole Round model (732-0001)
* All items are normally in factory stock.
**www.redingtoncounters.com**
**74**
**Totally Sealed Hour Meter**
**Electromechanical**
**Model 732**
## **Dimensions**
**==> picture [489 x 233] intentionally omitted <==**
**----- Start of picture text -----**<br>
2-Hole Flush-Rectangular<br>1.43<br>1.43 [36.3]<br>[36.3] 0.69<br>0.69 [17.5]<br>[17.5]<br>MOUNTING<br>CLIP<br>2.82<br>[71.6]2.82 2.15 [71.6] 2.15<br>[54.6] [54.6]<br>0.03 TO 0.63<br>[0.76 TO 16.00]<br>0.19[4.8] 0.06[1.5] 2.12 [53.8][35.8]1.41 2X Ø.15 [Ø3.8] 0.19[4.8] 0.06[1.5] [35.8]1.41 PANEL THICKNESS<br>0 0 0 0 0<br>ie [31.7]1.25 _ 0 0 0 0 00 0 0 0 0 a 0 y [23.4]0.92 [23.4]0.92 — [31.7]1.25 — 0 0 0 0 00 0 0 0 0 0 = [23.1]0.91 rT [23.4]0.92<br>=) om ae<br>[44.4]1.75 1/4" [6.3] TERMINAL [45.0]1.77 1/4" [6.3] TERMINALS<br>Panel Opening: 1.45" X 0.95" [36.8 X 24.1]<br>Panel Opening: 1.45" X 0.95" [36.8 X 24.1]<br>Maximum Panel Thickness: 0.03 to 0.63 [0.76 to 16.00]<br>**----- End of picture text -----**<br>
## **Flush-Round**
## **3-Hole Round**
**==> picture [229 x 173] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.69 [43.0]<br>1.53 [38.9]<br>0.40 [10.2] MAX<br>PANEL THICKNESS<br>MOUNTING<br>CLIP<br>1/4" [6.3] TERMINAL<br>Ø2.33<br>[59.2] 0 0 0 0 00 0 0 0 0 0 Ø1.99 [50.5] 0.69 [17.5]<br>0.22 [5.6]<br>1.50 [38.1]<br>0.49 [12.5]<br>**----- End of picture text -----**<br>
Panel Opening: 2.0" [50.6] Maximum Panel Thickness: 0.40 [10.2]
**==> picture [231 x 186] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.69 [43.0]<br>3X Ø.15 [Ø3.8]<br>3X Ø.13 [Ø3.3] Ø2.54 [Ø64.5] 1.53 [38.9]<br>Ø2.44 [Ø62.0]<br>1/4" [6.3] TERMINAL<br>Ø2.80 Ø1.99<br>[71.1] 0 0 0 0 00 0 0 0 0 0 [50.5] 0.69 [17.5]<br>0.22 [5.6]<br>3X 120˚ 1.50 [38.1]<br>0.49 [12.5]<br>Panel Opening: 2.0" [50.6]<br>**----- End of picture text -----**<br>
## **Applications**
**==> picture [64 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Medical Equipment<br>**----- End of picture text -----**<br>
**==> picture [88 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Outdoor power equipment<br>**----- End of picture text -----**<br>
**==> picture [47 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Utility Vehicles<br>**----- End of picture text -----**<br>
**www.redingtoncounters.com**
**75**
**LCD Tachometer**
**Model 53**
**Electronic**
## **Description**
The Model 53 Tachometers are self-powered by an internal lithium battery. They provide a low cost solution to accurately measure speed or production rates for a number of manufacturing and process applications. A wide selection of inputs, dry contact closure, 3-30VDC or 20-250VAC/VDC, make the Model 53 adaptable to most applications. When used with the appropriate sensor, the unit can display units per minute, length per minute or revolutions per minute. The maximum input rate is 10,000 counts per minute.
## **Features**
- Lithium battery
- **•** Choice of non-reset or remote reset **•** Switch (no-voltage), 3-30VDC, 20-250VAC/VDC
## **Options**
- Termination
- **•** Case color **•** Private labeling **•** Mounting adapter plates • 5003-001S - gasket
## **Specifications**
**Figures:** 4 LCD figures, 0.32” [8mm] high **Reset:** Remote, manual, or non-reset **Speed:** 10,000 counts/minute **Inputs:** Switch (no-voltage), 3-30VDC, 20-250VAC/VDC **Power:** Self-powered (internal lithium battery) **Mounting:** Panel **Terminations:** Terminal block, or connector -w/ 8’’ [200mm] wire leads **Battery Life:** ~20years **Temperature: Operating:** -4°F to +140°F [-20°C to +60°C] **Storage:** -40°F to +165°F [-40°C to +75°C]
**Humidity:** 0 to 95% RH, non-condensing **Vibration: Operating:** 10 to 55Hz, 0.01” [0.25mm] double amplitude **Non-Operating:** 10 to 55Hz, 0.03” [0.75mm] double amplitude **Shock: Operating:** 10G **Non-Operating:** 30G **Dielectric:** 1000VAC 50/60Hz for 1 minute **Accuracy:** Typically within 1% above 700Hz **Weight:** 2 oz. [57g] **Approvals:** UL Recognized, CSA Certified, CE Compliant
## **Models**
|**Models**|**Reset**<br>**Input**|**Reset**<br>**Input**|**Reset**<br>**Input**|**Input**|**Input**|**Input**|**Speed/RPM Terminations**|**Speed/RPM Terminations**<br>**Color**|**Speed/RPM Terminations**<br>**Color**|**Color**|**Color**|
|---|---|---|---|---|---|---|---|---|---|---|---|
||remote none manual switch 3-30VDC|none manual switch 3-30VDC|none manual switch 3-30VDC|none manual switch 3-30VDC|none manual switch 3-30VDC|20-250VAC/VDC|10,000 2500 term. block 8” wire leads|2500 term. block 8” wire leads|2500 term. block 8” wire leads Tan|Tan|Black|
|5330-0000<br>5330-0001<br>a|X<br>X||ee|X<br>X<br>ee|ee|ee|X<br>X<br>ee|X<br>X<br>eee|eee|X<br>eee|X<br>eee|
|5330-1000<br>5330-1001<br>a<br>FP|X<br>X<br>ttt|ttt|ee<br>tttitt|ee<br>itt|X<br>X<br>ee<br>itt|ee<br>itt<br>tT|X<br>X<br>ee<br>tTdy|X<br>X<br>eee<br>dyft|eee<br>ft|X<br>eee|X<br>eee|
|5330-2000<br>5330-2001<br>5330-2200<br>5330-2201<br>a<br>FP|X<br>X<br>ttt|X<br>X<br>ttt|ee<br>tttitt|ee<br>itt|ee <br>itt|X<br>X<br>X<br>X<br> ee <br>itt<br>tT|ee<br>tTdy|X<br>X<br>X<br>X<br>X<br>X<br>X<br>X<br>eee <br>dyft|eee <br>ft|X<br>X<br> eee|X<br>X<br>eee|
* All part numbers shown are for 7 digit models. Please contact the factory for information on 8 digit models.
**Dimensions**
**TERMINAL BLOCK WIRE LEADS** 1.58 [40.0] 1.72 [43.7] 1.92 [48.8] 1.92 [48.8] 0.10 [2.5] 1.47 [37.3] 0.10 [2.5] 1.47 [37.3] Ho ~~a~~ aE sl 1.02 [25.9] 0.86 [21.8] 1.02 [25.9] 0.86 [21.8] Ee =e
**www.redingtoncounters.com**
**76**
on **Model 53**
**LCD Tachometer**
**Electronic**
## **Operating Instructions**
## **MOUNTING:**
**==> picture [495 x 326] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.79 +/- 0.01<br> [45.5 +1/-0]<br>0.89 +/- 0.01 Panel Cutout<br> [22.6 +1/-0]<br>Colt 4<br>Optional<br>Unit<br>Gasket Panel Clip The mounting clip accommodates panel thicknesses up to 1/4”<br>[6.4mm].<br>WIRING:<br>Panel adapter plates are available in flush and 2 hole mount to fit<br>SWITCH (non-voltage) various panel cutouts. Consult the factory for availability.<br>1 2 3 4 5<br>INPUT RESET<br>Color code for the 8” [203mm] lead wires (24AWG) are:<br>Pin 1 used for 0 - 10,000 RPM)Pin 2 used for 0 - 2, 500 RPM) 1 - Yellow<br>2 - Blue<br>3 - 30 VDC 3 - Black<br>4 - Violet<br>1 2 3 4 5 5 - Gray<br>INPUT +DC +DC RESET<br>Pin 1 used for 0 - 10,000 RPM) Terminal block will accept wire sizes from 14 to 24AWG.<br>Pin 2 used for 0 - 2, 500 RPM)<br>20 - 250VAC/VDC 3 - 30VDC units are protected for transient voltages up to 50 volts<br>with pulse widths of up to 1 second at a 1% duty cycle (including<br>1 2 3 4 5 reverse polarity).<br>INPUT AC/DC AC/DC RESET The operating AC frequency range is 40 to 400Hertz.<br>Pin 1 not used<br>**----- End of picture text -----**<br>
Panel adapter plates are available in flush and 2 hole mount to fit various panel cutouts. Consult the factory for availability.
## **NOTES:**
All resettable hour meters can be reset by a pulse with a minimum duration of 6 milliseconds.
## **SPECIAL WIRING OPTION**
There is an internal connection between pin 3 and pin 5, a single wire can be used by connecting it to either pin 3 or pin 5. This option **does not** apply for units with input of 20 - 250VAC/VDC or manual reset enable.
## **OPTIONAL INPUTS:**
Optional control circuity (such as transistors) may be used as inputs provided that such circuitry provides the required parameters of the model used.
## **Applications**
Motor/pulley Speed
**www.redingtoncounters.com**
**77**
**Model 85**
**Electronic**
**Modular Panel Meter**
## **Description**
The Model 85 is a 3 1/2 digit, Modular Digital Panel Meter, where input and output modules can be selected to suit multiple applications. Input Modules are available to indicate Voltage, Amperage, Pressure, Temperature, Rate, Ohms and Frequency. User -friendly programming allows the user to program scaling and set points. The Model 85 includes peak/valley (min/max) and password protection as standard features. The housing is easy to mount and ensures a protection degree of IP 65. The Model 85 can be ordered with or without Program Lock.
## **Features**
- Modular Panel Meter 3 1/2 digit
- Optional bright red or green display
- Multirange input modules reduce inventory
- Popular 1/8 DIN mounting
- Indicating or controlling current, voltage, resistance, temperature, tachometer or frequency
## **Options**
- Display color
- Output type
- Input voltage
- Value to display or control
- Program lock
- Easily programmed
- Optional password protection of programming parameters
- Data hold
- Peak/valley (min/max) function
- Programmable hysteresis and time delay (up to 2 set points)
- IP 65 front cover
## **Specifications**
## **General Specifications**
## **Power Supply Specification**
**Display:** 7-segment LED, 0.55” [14mm] high, (2 LED’s for indication of relay ON). Min./ max. indication, -1999/1999 Over range indication: EE (under range: -EE) Accuracy: See module specifications Temperature drift: See module specifications Scaling: Electrical input range: Program within whole range Display range: Program within whole range Decimal point position: Programmable **Module Connection:** Screw terminals **Environment:**
Program within whole range Program within whole range Programmable Screw terminals
Degree of protection: IP 65 (front) Operating temperature: +32°F to +122°F [0°C to +50°C] Humidity: R.H. <90% non-condensing Storage temperature: +14°F to +140°F [-10°C to 60°C] Humidity: R.H. <90% non-condensing **Weight:** Approx. 12.4 oz [352g] Housing: Dimensions: 1.9” x 3.9” x 3.5” [48.3 x 99.1 x 88.9mm]
Material: Housing: ABS/Polycarbonate blend Front: Polycarbonate Color: Black housing Red front with red display Gray front with green display UL, cUL, CE Compliant
**Approvals:**
|**Power Supply AC:**<br>Rated operational voltage:<br>Frequency:<br>Voltage interruption:<br>Rated insulation voltage:<br>Rated impulse withstand voltage:|Over voltage cat.III<br>(IEC 60664)<br>230 VAC<br>+ 10%<br>115 VAC<br>+10%<br>48 VAC<br>+ 10%<br>24 VAC<br>+ 10%<br>50/60 Hz<br>+ 5 Hz<br><20ms<br>250 VAC basic rms<br> 6kV (1.2/50 msec)<br>IEC 60664-1|
|---|---|
|**Power Supply DC**:||
|Rated operational voltage:<br>Voltage interruption:<br>Rated insulation voltage:<br>Rated impulse withstand voltage:|12 to 48 VDC<br>+15%<br>< 10 ms (voltage =<br>10 VDC)<br>150 VDC basic<br> 4.0 kV (1.2/50 msec)<br>IEC 60664-1|
|**Rated Operational Power:**|< 7 VA|
|**ECM:**|Electromagnetic|
|Immunity:|compatibility<br>Acc. to IEC 60801-4<br>Acc. to IEC 60801-5|
**www.redingtoncounters.com**
**78**
**Model 85 Electronic Modular Panel Meter Input Specifications - Modules Pressure Indicator** The Model 85 can be used to indicate pressure by using the **Voltmeters DC (85KSVD/85KLVD)** DC Amperage or DC Voltage input module. You can then program the unit to limit the range to 20mA or 20VDC and progarm the engineering **AC (85KSVA/85KLVA)** units to display the corresponding pressure reading. **Measuring Jumper Range ResolInput Max. Range position Code ution Impedance Overload Ohmmeter (85KSIR/85KLIR) AC DC** 199.9 mV 1-4 7 1 0.1 mV 100 KW 50 V **Measuring Jumper Range Code Resolution Ranges position AC** 1.999 V 2-5 8 2 1 mV 100 KW 230 V 199.9 W 1-4 7 0.1 Ω 19.99 2-5 9 3 10 mV 1 MW 690 V 1999 W 2-5 8 1 Ω 199.9 V 3-6 10 4 0.1 V 1 MW 690 V 19.99 kW 3-6 9 0.01 k Ω 600 V* 5-6 12 6 1 V 1 MW 690 V ~~fic~~ 199.9 kW 1-2 10 0.1 k Ω *Nominal voltage according to IEC 664-1. The measuring range **Accuracy** 0.2% of reading + 2 dgt includes 15% tolerance to 690 V. **Temperature Drift** + 150 ppm/°F + 0.1 dgt/°F **Accuracy** AC voltmeter 0.3% of reading + 3 dgt **Tachometers (85KSTK/85KLTK)** DC voltmeter 0.2% of reading + 2 dgt **Measuring Jumper Range Resolution Temperature Drift** AC voltmeter + 150 ppm/°F + 0.2 dgt/°F 199.9 RPM @ 30PPR* J4, 1-2 7 0.1 RPM DC voltmeter + 100 ppm/°F + 0.05 dgt/°F 199.9 RPM @ 60PPR* J5, 1-2 8 0.1 RPM **Ammeters DC (85KSCD/85KLCD)** 199.9 RPM @ 100PPR* J6, 1-2 9 0.1 RPM **AC (85KSCA/85LCA) AC/DC (85KSAD/85KLAD)** 1999 RPM @ 30PPR* J4, 2-3 10 1 RPM 1999 RPM @ 60PPR* J5, 2-3 11 1 RPM **Range Measuring Jumper Code Resolution Max.** 1999 RPM @ 100PPR* J6, 2-3 12 1 RPM **Range position AC DC Overload** * Pulses per revolution 199.9 mA 1-2 7 1 0.1 mA 20 mA **Input Selection Namur** J1 1999 mA 2-3 8 2 1 mA 100 mA **NPN, PNP, Contact** J2 19.99 mA 4-5 9 3 10 mA 200 mA **Accuracy** 1% of reading +5 dgt **Temperature Drift** +200 ppm/°F 199.9 mA 5-6 10 4 0.1 mA 500 mA **Input Impedance Namur** 1 kW 1999 mA 2-5 11 5 1 mA 4 A **NPN, PNP, Contact** 5 kW 5.00 A 2-5 12 6 10 mA 8 A **Time Constant (tc)** 1 sec. 10 A DC 1-2(DC) 6 10 mA 10 A **Frequency Meters (85KSFQ/85KLFQ)** 10 A AC 2-3(AC) 12 10 mA 10 A **Measuring Jumper Range Resolution Ranges Position Code Accuracy** 199.9 Hz J7 7 0.1 Hz AC ammeter 0.3% of reading + 3 dgt 1999 Hz J8 8 1 Hz AC ammeter (10 A) 0.5% of reading + 3 dgt **Input Selection** DC ammeter 0.2% of reading + 2 dgt Namur J1,J4 and J6 ~~c~~ DC ammeter (10 A) 0.5% of reading + 2 dgt NPN, PNP, Contact J2 and J5 **Temperature Drift** 600 VAC J3 AC ammeter + 150 ppm/°F + 0.5 dgt/°F 150 ppm/°F + 0.5 dgt/°F+ 0.5 dgt/°F 0.5 dgt/°F **Accuracy** 1% of reading +5 dgt AC ammeter (2A,5A) + 200 ppm/°F + 0.1 dgt/°F 200 ppm/°F + 0.1 dgt/°F+ 0.1 dgt/°F 0.1 dgt/°F **Temperature Drift** +200 ppm/°F AC ammeter (10A) + 200 ppm/°F + 0.5 dgt/°F 200 ppm/°F + 0.5 dgt/°F+ 0.5 dgt/°F 0.5 dgt/°F **Input Impedance**
AC ammeter + 150 ppm/°F + 0.5 dgt/°F 150 ppm/°F + 0.5 dgt/°F+ 0.5 dgt/°F 0.5 dgt/°F AC ammeter (2A,5A) + 200 ppm/°F + 0.1 dgt/°F 200 ppm/°F + 0.1 dgt/°F+ 0.1 dgt/°F 0.1 dgt/°F AC ammeter (10A) + 200 ppm/°F + 0.5 dgt/°F 200 ppm/°F + 0.5 dgt/°F+ 0.5 dgt/°F 0.5 dgt/°F DC ammeter + 100 ppm/°F + 0.05 dgt/°F DC ammeter (2A,5A) + 200 ppm/°F + 0.5 dgt/°F DC ammeter (10A) + 200 ppm/°F + 0.5 dgt/°F <200 mV (all ranges)
Namur 1 kW NPN, PNP, Contact 5kW 600 VAC 600 kW **Time Constant (tc)** 1 sec.
## **Voltage Drop**
**www.redingtoncounters.com**
**79**
**Model 85**
**Modular Panel Meter**
## **Electronic**
## **Thermometers**
## **Output Specifications - Modules**
## **Relay Outout 1 or 2 Relays (85KSR1/85KSR2)**
## **Pt 100: RTD (85KSRT/85KLRT)**
|**Range**|**Resolution**|**Resolution**<br>**Accuracy**|**Temperature**<br>**Drift**|
|---|---|---|---|
|-100.0 to 199.9 °C|0.1 °C|+ 0.2% of reading<br>+ 2dgt|0.2% of reading<br>+150 ppm/°C<br>+0.05 dgt/°C|
|-148 to 199.9 °F|0.2 °F|+0.2% of reading<br>+4 dgt|+180 ppm/°F<br>+0.10 dgt/°F|
|-148 to 392 °F|1 °F|+0.2% of reading<br>+ 4 dgt|+180 ppm/°F<br>+0.10 dgt/°F|
## **Pt 100, 1562°F/850°C**
## **(85KSPT/85KLPT)**
|**Range**<br>**Resolution**|**Resolution**|**Accuracy**|**Temperature**<br>**Drift**|
|---|---|---|---|
|-100.0 to 850 °C|1 °C|+ 0.2% of reading<br>+ 3 dgt|+150 ppm/°C<br>+0.05 dgt/°C|
|-148 to 1562 °F|2 °F|+0.4% of reading<br>+6 dgt|+180 ppm/°F<br>+0.10 dgt/°F|
**Power Supply** Supplied by main unit **Output** 1 or 2 SPDT relays **Rated Insulation Voltage** 250 V basic RMS **Contact Ratings (AgCdO)** Resistive AC 1 5A, 250 VAC DC 1 5A, 24 VDC Small inductive AC 11 2A, 250 VAC loads DC 11 3A, 24 VDC **Mechanical Life** > 40 x 10[6] operations **Electrical Life** > 10[5] operations (at max load) **Operating Frequency** max. 10Hz (50% duty cycle) **Dielectric Strength** Dielectric voltage 2 kVAC (rms) Rated impulse withstand 4 kV (1.2/50ms) voltage
## **NPN Output 2 Transistor Outputs (85KSNP)**
**NPN Open Collector:** ISNK = 100mA max. @ VOL = 1.0 VDC max. VOH = 30 VDC max. 12VDC/+15%, 40 mA, voltage output is provided
## **Thermocouple type J (85KSJT/85KLJT)**
|**Range**<br>**Resolution**|**Resolution**|**Accuracy**|**Temperature**<br>**Drift**|
|---|---|---|---|
|-100.0 to 760 °C|1 °C|+ 0.1% of reading<br>+ 4 dgt|+100 ppm/°C<br>+0.05 dgt/°C|
|-148 to 1400 °F|1 °F|+0.1% of reading<br>+8 dgt|+180 ppm/°F<br>+0.10 dgt/°F|
## **Thermocouple type K (85KSKT/85KLKT)**
|**Range**<br>**Resolution**|**Resolution**|**Accuracy**|**Temperature**<br>**Drift**|
|---|---|---|---|
|-100.0 to 1250 °C|1 °C|+ 3% of reading<br>+ 3 dgt|+100 ppm/°C<br>+0.05 dgt/°C|
|-100 to -50 °C|1 °C|+1% of reading<br>+5/-1 dgt|+100 ppm/°C<br>+0.05 dgt/°C|
|-50.0 to 780 °C|1 °C|+ 0.1% of reading<br>+ 3 dgt|+100 ppm/°C<br>+0.05 dgt/°C|
|780 to 1250 °C|1 °C<br>+0|+0.25% of reading<br>+1/-3 dgt|+100 ppm/°C<br>+0.05 dgt/°C|
|-148.0 to 1999 °F|2 °F|+ 3% of reading<br>+ 6 dgt|+180 ppm/°F<br>+0.10 dgt/°F|
|-148 to -58 °F|2 °F|+1% of reading<br>+10/-2 dgt|+180 ppm/°F<br>+0.10 dgt/°F|
|-58.0 to 1436 °F|2 °F|+ 0.1% of reading<br>+ 6 dgt|+180 ppm/°F<br>+0.10 dgt/°F|
|1436 to 1999 °F|2 °F<br>+0|+0.25% of reading<br>+2/-6 dgt|+180 ppm/°F<br>+0.10 dgt/°F|
## **Excitation Output (85KSDC)**
**Power Supply** Supplied by main unit **Output Voltage** 12 VDC: jumper position 3-6 tolerance +20% 24 VDC: jumper position 1-4 tolerance +20% **Output Current** 12 VDC < 35 mA DC 24 VDC < 20 mA DC **EMC** Electromagnetic compatibility Immunity Acc. to IEC 60801-4 Acc. to IEC 60801-5
## **Analog output (85KSAN)**
|**Measuring**<br>**Range**|**Load**<br>**Resistance**|**Accuracy**|
|---|---|---|
|0 to 20 mA|<500Ω|+1% of reading<br>+0.1 mA|
|4 to 20 mA|<500Ω|+1% of reading<br>+0.1 mA|
|0 to 10 V|<1,000Ω|+1% of reading<br>+0.05 V|
**Temperature Drift** +200 ppm/°C **Short-Circuit Protection** yes **Analog Output Porportional to Input Signal.** low input signal = low analog output high input signal = high analog output **Time Constant** 1 sec.
**www.redingtoncounters.com**
**80**
**Electronic**
**Model 85**
**Modular Panel Meter**
## **Operation Details**
## **Operation Diagrams**
## **Mode of Operation**
**Setpoint Operation**
Depending upon the input modules used, it is possible to measure current, voltage, or resistance ...etc. The range is selected with a jumper on the input module and programming. Without an output module the Model 85 is an indicator - by inserting an output module the Model 85 is a controller.
**==> picture [499 x 278] intentionally omitted <==**
**----- Start of picture text -----**<br>
SP +Hyst The input range and the display range are fully programmable, and<br>so are the setpoint(s) if a relay output module is inserted.<br>SP<br>A hold function is available for freezing a measured value. Pass-<br>words 0 to 99 are for overall programming with passwords 100 to<br>SP -Hyst<br>199 allow direct setpoint programming outside the password<br>PV protection. See user manual for futher details.<br>Delay<br>UP/ND — Overall Dimensions<br>UP/NE<br>Delay Front View<br>3.78" [96mm]<br>Output activates as input signal rises above setpoint (High Alarm)<br>DO/ND 2<br>Delay Delay 3<br>oe<br>Delay<br>Delay<br>DO/NE 1.89"<br>[48mm]<br>Output activates as input signal drops below setpoint (Low Alarm)<br>1 2<br>S REDINGTON V<br>Scaling Operation<br>1 4<br>**----- End of picture text -----**<br>
The input range and the display range are fully programmable, and so are the setpoint(s) if a relay output module is inserted. A hold function is available for freezing a measured value. Passwords 0 to 99 are for overall programming with passwords 100 to 199 allow direct setpoint programming outside the password protection. See user manual for futher details.
Panel Cutout 1.77” [45mm] X 3.62” [92mm]
**==> picture [459 x 251] intentionally omitted <==**
**----- Start of picture text -----**<br>
Cutouts can be up to .02” [0.5mm] larger<br>Electrical Input Range Display Range Display Indication<br>1999 1999<br>EE<br>HiE<br>HI SideView<br>See<br>Formula<br>LO Below<br>LOE Max. 0.32" [8.2mm]<br>0 0<br>-EE<br>-1999 -1999<br>Formula (HI - LO) * (Xin - LOE) +LO Max. 0.47" [12.0mm]<br>(HiE - LOE) 3.24" [82.2mm]<br>_ cn<br>www.redingtoncounters.com<br>**----- End of picture text -----**<br>
**81**
| | **Model 85**
**Electronic**
**Modular Panel Meter**
## **Rear view of main unit**
**==> picture [520 x 359] intentionally omitted <==**
**----- Start of picture text -----**<br>
Slot Slot Slot Slot Slot<br>om | ft Nias Vomait b<br>#1 #2 #3 #4 #5<br>Gun. 7S fi) ¢.. ce<br>emss, ok )aN - |ee @ SS.2<br>*) — oo o o *) *) et alll col *) Rear View Assembled Unit<br>@@@ 15 e<br>@ 18<br>Module Slot Identification:<br>@ @ @ A 2 - ( 16 @<br>@ IN LO @ @ 12 - 48 VDCA 1 + ‘ox m ) Each module is clearly marked with a diagram showing which slot it shouldbe inserted in.<br>IN HI0.2/2V ~ Slot 1<br>;| + EXC |s) is} |e} soo eg<br>12/24 VDC HOLD<br>IN HI20/200/ - EXC<br>600V ~ Slot 2<br>A ! ° °A ! A ! AC1.5A,250V~ °A ! a ae ridesah @)<br>Input Module: Output Power Supply Relay Output Slot 3 & 4<br>VAC Modules: Modules: Modules:<br>VDC 12 VDC Excitation (Requires 2 slots) 1 SPDT(Form C),<br>AAC 24 VDC Excitation 24 VAC 5A<br>ADC or 48 VAC 2 SPDT(Form C), Slot 5<br>10A AC/DC Analog output 115 VAC 5A ohen<br>W 0-20 mA 230 VAC 2 NPN<br>Uo:t2vers4oma/\.<br>PT 100 4 - 20 mA 12 - 48 VDC<br>J-type Thermocouple 0 - 10 VDC<br>K-type Thermocouple<br>Tachometer<br>Frequency<br>**----- End of picture text -----**<br>
**==> picture [432 x 227] intentionally omitted <==**
**----- Start of picture text -----**<br>
Interchangeable Engineering Unit Labels<br>Red or Green Display Unit VookKV A mA W_<br>— KO Hz kHz “G “Fo<br>| mbar bar psi kg/cm’ io<br>myh mm cm m “Kg<br>~ MW 2) MQ Imin<br>| Ah eel RPM kvar m/min ppm cos?<br>Mounting Adapter<br>Input Module Power Supply Relay/NPN<br>Module Output Module<br>Output Module<br>2 ™<br>Gasket<br>Blank Rear Inserts<br>C3 ——<br>**----- End of picture text -----**<br>
**www.redingtoncounters.com**
**82**
| | **Model 85**
**Electronic**
**Modular Panel Meter**
## **Applications**
Temperature
Volts/Amps/Ohms
Speed Control
## **Ordering Information**
## **Component Selection - Part Number**
To order assembled (built-up) panel meters, see following “Part Number Selection” section.
To order components, select modules from each of the categories below to construct an Indicator or Controller. For additional guidance, consult the flowchart on the right.
## **Component Selection Flowchart**
||**Ordering**|**w/Program**|**Component Selection Flowchart**|**Component Selection Flowchart**|**Component Selection Flowchart**|
|---|---|---|---|---|---|
||**Number**|**Lock**|To build an indicator, choose display color, power supply, and|||
|**Main Unit**|||input module. For a controller, also choose an analog/excitation|||
|Red Display (standard red)|**85KSRD**||output and/or output module.|||
|Red Display (high efficiency red)|**85KSHR**|||||
|Green Display|**85KSHG**||**INDICATOR**<br>**CONTROLLER**<br>******|||
|**Power Supply Modules**||||||
|12 to 48 VDC|**85KSP1**|||||
|24 VAC|**85KSP2**||**DISPLAY**<br>**COLOR?**<br>**DISPLAY**<br>**COLOR?**|||
|48 VAC|**85KSP3**|||||
|115 VAC|**85KSP4**|||||
|230 VAC|**85KSP5**|||||
|**Input Modules**|||**POWER**<br>**SUPPLY?**<br>**POWER**<br>**SUPPLY?**|||
|DC Voltage|**85KSVD**|**85KLVD**||||
|AC Voltage|**85KSVA**|**85KLVA**||||
|DC Amperage|**85KSCD**|**85KLCD**||||
|AC Amperage|**85KSCA**|**85KLCA**||||
|AC/DC Amperage (10A)|**85KSAD**|**85KLAD**|**INPUT**<br>**INPUT**|||
|Resistance (Ohms)|**85KSIR**|**85KLIR**|**TYPE?**<br>**TYPE?**|||
|PT 100 RTD (can be scaled to °F)|**85KSRT**|**85KLRT**||||
|PT 100 RTD (up to 1562°F/850°C)|**85KSPT**|**85KLPT**||||
|J-Type Thermocouple (can be scaled to °F)|**85KSJT**|**85KLJT**||**ANALOG**||
|K-Type Thermocouple (can be scaled to °F)|**85KSKT**|**85KLKT**|**END**<br>**OR**|||
|Tachometer|**85KSTK**|**85KLTK**||**EXCITATION**<br>**OUTPUT?**||
|Frequency<br>**Output Modules (optional)**|**85KSFQ**|**85KLFQ**|**ANALOG**<br>**OUTPUT**<br>**SIGNAL?**<br>**** It is possible to construct**<br>**an indicator with an**<br>**excitation or analog output**||**EXCITATION**<br>**OUTPUT**<br>**VOLTAGE?**|
|1 Relay|**85KSR1**|||||
|2 Relays|**85KSR2**|||||
|2 NPN Transistors|**85KSNP**|||||
|*12/24 VDC Excitation Output/for sensor supply|**85KSDC**|||**OUTPUT?**||
|*Analog Output|**85KSAN**|||||
|*Analog and excitation output modules occupy the same plug-in location, therefore only|*Analog and excitation output modules occupy the same plug-in location, therefore only|*Analog and excitation output modules occupy the same plug-in location, therefore only||||
|one selection is possible.||||||
|*Items in bold are normally in factory stock.||||**END**||
To build an indicator, choose display color, power supply, and input module. For a controller, also choose an analog/excitation output and/or output module.
**www.redingtoncounters.com**
**83**
**Model 85**
**Electronic**
**Modular Panel Meter**
## **Part Number Selection - Assembled Unit(s)**
_Note: There is a 10 piece minimum of various assembled meters, not one specific part number._
8 5 x x x x x x x x x x
## **Ordering Key**
## **Model Number** Model 85 **Input Type and Range Code**
**DC Ammeters AC Ammeters AC Voltmeters** CD1 -199.9 to + 199.9 mA CA1 0 to 199.9 mA VA1 0 to 199.9 mV CD2 -1.999 to +1.999 mA CA2 0 to 1.999 mA VA2 0 to 1.999 V CD3 -19.99 to +19.99 mA CA3 0 to 19.99 mA VA3 0 to 19.99 V CD4 -199.9 to +199.9 mA CA4 0 to 199.9 mA VA4 0 to 199.9 V CD5 -1999 to +1999 mA CA5 0 to 1999 mA VA5 0 to 600 V* CD6 -5.00 to +5.00 A CA6 0 to 5.00 A CD7 -10.00 to +10.00 A CA7 0 to 10.00 A * Nominal voltage according to IEC60-664-1. The measuring range includes 15% tolerance equal to 690 V.
|**DC Voltmeters**|**Ohmmeters**|**Ohmmeters**|**Tachometer**|**Tachometer**|
|---|---|---|---|---|
|VD1<br>-199.9 to +199.9 mV<br>VD2<br>-1.999 to +1.999 V<br>VD3<br>-19.99 to +19.99 V<br>VD4<br>-199.9 to +199.9 V<br>VD5<br>-600 to +600 V<br>RO1<br>RO2<br>RO3<br>RO4||0 to 199.9 W<br>0 to 1.999 kW<br>0 to 19.99 kW<br>0 to 199.9 kW|_NAMUR Input_<br>TA1<br>8.0 to 199.9 RPM @ 30PPR<br>TA2<br>5.0 to 199.9 RPM @ 60PPR<br>TA3<br>2.0 to199.9 RPM @ 100PPR<br>TA4<br>20 to 1999 RPM @ 30PPR<br>TA5<br>10 to 1999 RPM @ 60PPR||
||||TA6|120 to 1999 RPM @ 100PPR|
||||_NPN, PNP or Contact Input_||
|**Frequency Meters**|**Thermometers**||TB1|8.0 to 199.9 RPM @ 30PPR|
|_Namur Inputs_|**_J-Type TC:_**||TB2|5.0 to 199.9 RPM @ 60PPR|
|FO1<br>5.0 to 199.9 Hz|JC1|-100 to 760°C|TB3|2.0 to 199.9 RPM @ 100PPR|
|FO2<br>10.0 to 1999 Hz|JF1|-148 to 1400°F|TB4|20 to 1999 RPM @ 30PPR|
|_NPN, PNP or_|**_K-Type TC_**||TB5|10 to 1999 RPM @ 60PPR|
|_Contact Input_|KC1|-100 to 1250°C|TB6|10 to 1999 RPM @ 100PPR|
|FS1<br>5.0 to 199.9 Hz|KF1|-148 to 1999°F|||
|FS2<br>10.0 to 1999 Hz|**_PT100 RTD_**||||
|_NPN, PNP or_|PC1|-100.0 to 199.9 °C|||
|_600 VAC Input_|PF1|-100 to 850°C|||
|F61<br>5.0 to 199.9 Hz|PC2|-148.0 to 199.9°F|||
|F62<br>10.0 to 1999 Hz|PF2|-148 to 392°F|||
||PF3|-148 to 1562°F|||
## **Power Supply**
1) 12-48 VDC 2) 24 VAC 3) 48VAC 4) 115 VAC5) 230 VAC
## **Relay Output**
N) None 1) One Relay 2) Two Relays 3) NPN
## **Output Modules**
N) None 1) 0-20mA 2) 4-20mA 3) 0-10 VDC 4) 12 VDC Excitation 5) 24 VDC Excitation
## **Display Color**
R) Red G) Green H) High Efficiency Red
## **Hardware Lock of Programming**
S) None L) Program Lock
## **Engineering Label**
01 to 47 (see front panel description #4)
**www.redingtoncounters.com**
**84**
Lt **Model 88**
**LCD Programmable Indicator/Controller**
**Electronic**
## **Description**
The Model 88 is a family of LCD Indicators/Controllers, with eight 7-segment digits that are 0.35" [9mm] in height. The standard display is a backlit LCD, providing red characters on a dark background. An optional reflective LCD with dark characters on a light background is available. Unit programming is accomplished using four front-panel switches, or programming can be done using the optional serial data interface and dedicated PC-based software (Redi-Ware), which is available from Redington free of charge. Upon power up, the Indicator/Controller performs internal diagnostics and flashes all segments of the display “ON” and “OFF” several times. The Indicator/Controller then configures itself per previous programming, loads the internal Counters and Timers with their values prior to power down, and begins normal operation.
The Model 88 Indicator/Controller is capable of receiving counts and/or analog inputs, processing those inputs in a number of different selectable ways, and then providing outputs in several formats. Base units, i.e.; #8800-0000, or similar units can be programmed for Elapsed Time, Rate, Preset Count/Time, count Add/Add, count Add/Sub., or count Quadrature. The two independent control outputs are open-collector (NPN) outputs that can be controlled by either count inputs, time, the analog input, or combinations of the analog input/time and count inputs. Based on two inputs, the indicator is capable of displaying two counts, a rate indicator and an elapsed time at the same time. The base unit provides the display, programming, and processing functions for the final configuration as well as the counter I/O function. I/O functions and factory installed modules are available that allow the user to configure complex functions into a small enclosure. Other models add analog input/output functions to the base unit, and serial communication functions, which supports RS232/RS422/RS485, providing the user with a broad selection of configurations.
Each Model 88 base unit is normally powered from a DC voltage of +10V to + 32 V. However, an AC power supply module # 200557-002S can be attached to the rear of the unit that converts +90VAC to +250VAC, to +12VDC, which can be used to power the Model 88 and an external sensor. Another module, 200557-001S, can be added that converts the discrete outputs of the Model 88 base unit to relay contacts.
|**Features**|**Features**|**Options**||
|---|---|---|---|
|•|Dual up counting|||
|•|Preset of time, rate or count|•|Relay Module 200557-001S|
|•|Directional counting||2 form C, 5 amp relays|
|•|1,2,4x quadrature|•|Serial Comm. (RS232, RS422, RS485)|
|•|Add/add counting|•|Analog input/outputs|
|•|Add/subtract counting|•|Display color|
|•|Rate indication on count inputs|•|AC Power Module 200557-002S|
|•|Analog ranges: 0 to 10 VDC or 4 to 20 mA||+90 VAC to +285 VAC, 50/60 Hz (unit is|
|•|Prescaling of analog inputs and counts||normally powered from +10 VDC to +32 VDC)|
|•|Elapsed timer function available for all modes of operation|||
|•|NEMA 4X/IP56 sealed panel|||
|•|UL, cUL Recognized, CE Compliant UL file # E19514|||
## **Specifications**
**Display:** LCD, 8 digits, 0.35" [9mm] negative image transmisThree different quadrature resolutions sive red or positive image reflective display. In the Add-Add negative count mode the display will be 7 digits with a Add-Subtract “-” sign. (Reflective display recommended in sunlight) Dual Count Elapsed Time **Annunciators:** A, B, R, 1, 2 ANLG, LOCK, HZ, RPM, HRS, SEC. Analog Input 0.039’’ [1mm] Predetermining **Programming** : Programming is accomplished through the front panel **Predetermining** switches or by serial data interface and dedicated PC **Functions:** Preset units provide two discrete outputs which can software, supplied by Redington Counters, Inc. be controlled as a function of count, rate, elapsed time, or analog input. Each control output can be set **Available** by any of the four functions and reset by the same or **Functions:** Totalizer a different function. For example, control output 1 Directional Counting could be set when a specific count is reached and Rate/Count reset when an analog input level is reached.
**www.redingtoncounters.com**
**85**
**Model 88**
**LCD Programmable Indicator/Controller**
**Electronic**
## **Predetermining Timer:**
## **Programmable Ranges:**
## **Rate Indicator Accuracy:**
±0.01%, References Time Base @T=25°C
Hours
Seconds Hours, Minutes & Seconds
**Programmable Decimal Point:** Counter A: 4 decimal point locations may be selected. Counter B: 4 decimal point locations may be selected. Rate Display: 4 decimal point locations may be selected. Analog Input: 4 decimal point locations may be selected. Time: 4 decimal point locations may be selected. **Power Requirements:** Base unit: +10VDC TO +32VDC @ 50mA max. Relay Module: Model 200557-001S; +10VDC to +32VDC @ 50mA, max. AC Power Supply: Model 200557-002S; +90VAC to +250 VAC 50/60 Hz @ 6 VA max. **Memory:** Nonvolatile EEPROM retains all program parameters and values when power is removed. EEPROM provides 20 year data retention. **Sensor Power:** +12VDC @ 100mA, minimum (200557-002S Module) **Front Panel Lockout:** Two front panel lockouts are available. In the programming mode, the operator is prohibited from entering new parameters. In the operating mode, the lockout disallows manual reset of any displayed inputs. **Count/Timer Inputs (Input A & Input B):** Software selectable: switch contact or voltage input Software Selectable: filter: no filter or 160 Hz 1[st] order L.P. Voltage Mode VIH: 2.4VDC, min. Voltage Mode VIL: 0.8VDC, max. or open circuit Switch Mode VIH: 2.4 VDC, min. or open circuit Switch Mode VIL: 0.8VDC, max. Maximum Input voltage: 32.0VDC Minimum Input voltage: -0.8VDC
**Counter/Timer Operational Format:** Input A is used for all count functions Input B is used for timer enable and all dual Input counter functions (i.e. ADD/ADD, ADD-SUB, DIRECTIONAL COUNT, QUADRATURE, and DUAL COUNT). **Input Scaling:** A & B Counters and analog input, (- 9.9999 to 99.9999) **Quadrature Counting** : Software selectable X1, 2, 4 **Analog Input:** 0 to 10VDC or 4 to 20 mA Resolution: 4 digit **Input Impedence:** 150K ohms, for 0 to 10VDC 100 ohms, for 4 to 20 mA **Max. Count Rate:** 40 KHz for single counter mode. 20 KHz for dual count modes **Rate Input Units:** The rate input can be expressed in terms of scaled counts per minute (rP) or scaled counts per second (HZ) of counter A.
**Minimum Input Frequency:** 1 pulse in 10 seconds **Maxium Input Frequency:** 40 K HZ **Reset Functions:** (Automatic & manual) **Reset-to-Zero:** Can be programmed so that the output activates when counter equals the preset value, counter returns to zero when reset. **Reset-to-Preset:** Can be programmed so that the output activates when counter equals zero, Counter returns to Preset value when reset. **Resets:** Automatic or manual. **Outputs:** Base unit; Solid-state NPN: (2) Open collector:ISNK=100mA @VOL=1.1VDC VOH=40VDC **Relay Module:** Model 200557-001S; 2 form “C” relays rated @ 5 amps 250 VAC, 30VDC(resistive load) 1/10[th] HP @120VAC (inductive load) **Relay Life Expectancy:** 100,000 cycles min. @ max. rated load. **Programmable Timed Outputs:** Both control outputs can be timed. **Elapsed Timer Accuracy:** ± 0.01% @T=25°C **Analog Output:** 0 TO 10VDC OR 4 TO 20mA **Accuracy:** 0.25% of full scale @ T = 25°C **Resolution:** 14 bits **RS232/RS485/RS422 Serial Communications:** (Optional) **Baud Rate:** Selectable 2400, 4800, 9600, or 19.2K **Data Length/Parity/Stop Bits:** 8n1 **RS485 Address:** Programmable from 0 to 99. **Transceiver Loading:** RS232/RS485/RS422- up to 16 loads **Certifications & Compliances:** UL, cUL- Recognized Component, file # E 195514 CE-Compliant to EN 61326: 1998 for industrial equipment **Environmental Conditions: Operating Temperature:** -4°F to +140°F [-20°C to +60°C] **Storage Temperature:** -40°F to +185°F [-40°C to +85°C] **Operating & Storage Humidity** : to 95% (non-condensing) from -4°F to +140°F [-20°C to +60°C] **Altitude:** Up to 6561Ft. (2000 Meters)
**Electrical Connection:** Wire clamping screw terminals
**Construction:** High impact black plastic case with “Clip” type mount. Front panel meets NEMA 4X/IP65 requirements for indoors use, when properly installed. Oversized front panel flange insures proper sealing of panel cutouts. Gaskets for front panel are provided. **Panel Thickness** : 0.05" to 0.20" [1.3 to 5.1mm] **Weight:** Less than 3 oz. (85g)
**www.redingtoncounters.com**
**86**
Biel **Model 88**
**LCD Programmable Indicator/Controller**
**Electronic**
## **Models Description**
For Models and Descriptions see the Ordering Information section
## **Dimensions**
## **Model 88**
**==> picture [267 x 225] intentionally omitted <==**
**----- Start of picture text -----**<br>
4.33 [109.9]<br>3.21 [81.7]<br>0.13 [3.2]<br>2.59 [65.8]<br>2.96 [75.2]<br>Ey<br>———,<br>1.62 [41.1] 1.25 [31.8]<br>® J<br>Panel Cutout 2.63’’ to 2.605’’ x 1.28’’ to 1.26’’ [66.8 to 66.2 x 32.5 to 32.0]<br>Max. thickness of panel 0.5’’ [12.7]<br>**----- End of picture text -----**<br>
## **Applications**
**==> picture [368 x 94] intentionally omitted <==**
**----- Start of picture text -----**<br>
Batching Cut-to-length Elapsed time indicator<br>Flow and level control Rate/Indication or control<br>**----- End of picture text -----**<br>
**www.redingtoncounters.com**
**87**
**Model 88**
**LCD Programmable Indicator/Controller**
**Electronic**
## **Ordering Information**
|**MODEL**<br>**NUMBER**|**DESCRIPTION**|**DISPLAY**<br>**RED**<br>**TRANSMISSIVE**|**DISPLAY**<br>**REFLECTIVE**|**ANALOG**<br>**INPUT**|**ANALOG**<br>**OUTPUT**|**RS-485**<br>**RS-232**<br>**RS 422**|
|---|---|---|---|---|---|---|
|**8800-0000**|Base unit, Red Trans., 10-30VDC, Prescale|X|||||
|**8810-0000**|Base unit, Reflective, 10-30VDC, Prescale||X||||
|**8800-0100**|Red Trans., 10-30VDC, Prescale, Serial Communications|X||||X|
|**8810-0100**|Reflective, 10-30VDC, Prescale, Serial Communications||X|||X|
|**8800-0010**|Red Trans., 10-30VDC, Analog input, Prescale|X||X|||
|**8810-0010**|Reflective, 10-30VDC, Analog input, Prescale||X|X|||
|**8800-0001**|Red Trans., 10-30VDC, Analog output, Prescale|X|||X||
|**8810-0001**|Reflective, 10-30VDC, Analog output, Prescale||X||X||
|**8800-0110**|Red Trans., 10-30VDC, Analog input, Prescale, Serial Communications|X||X||X|
|**8810-0110**|Reflective, 10-30VDC, Analog input, Prescale, Serial Communications||X|X||X|
|**8800-0101**|Red Trans., 10-30VDC, Analog output, Prescale, Serial Communications|X|||X|X|
|**8810-0101**|Reflective, 10-30VDC, Analog output, Prescale, Serial Communications||X||X|X|
|**8800-0011**|Red Trans.,, 10-30VDC, Analog I/O, Prescale|X||X|X||
|**8810-0011**|Reflective, 10-30VDC, Analog I/O, Prescale||X|X|X||
|**8800-0111**|Red Trans, 10-30VDC, Analog I/O, Prescale, Serial Communications|X||X|X|X|
|**8810-0111**|Reflective, 10-30VDC, Analog I/O, Prescale, Serial Communications||X|X|X|X|
## ACCESSORIES
200557-001S Relay module 2 form C relays 200557-002S AC Voltage module, +90VAC to +250VAC also outputs +12VDC for base unit & sensor
_Note: Reflective display is recommended for applications that will be exposed to direct sunlight_
* All parts are normally in factory stock.
**www.redingtoncounters.com**
**88**
nia **Model 83**
**LCD Predetermining Counter**
**Electronic**
## **Description**
The 83 Counter features a 7 segment, 2 lines by 6-digit backlit LCD display. The main display line is red and shows the count value or the batch/ total value when preset 3 or output 3 is viewed in the secondary display. The smaller secondary display line is green and can be used to view the prescaler value, preset values, output count values or batch/total count values (batch model only).
The 83 Counter offers a choice of nine programmable counting modes for use in applications requiring bidirectional, anti-coincidence, and quadrature counting. The unit may be programmed to detect counts on both edges of the input signal resulting in a doubling of frequency. DIP switches are used for input configuration setup and to provide a program disable function.
Four front panel push buttons are used for ease of programming the operating modes and data values, to change the viewed display, and performing user programmable functions, e.g. reset, etc. The 83 Counter can be configured for one of two numeric date entry methods.
Digital - The digital entry allows for the selection and incrementing of digits individually.
Automatic Scrolling - This method allows for the progressive change of one through all digits positions by pressing and holding the **up** or **down** button.
Protection of data value and unit configuration - The program disable DIP switch, a user-programmable code value, and an external user input selected for program disable can be utilized to provide multilevel protection.
The standard with dual presets is available with solid-state and relay outputs. The batch counter has relay outputs for output 2 and the batch/total output 3, with output 1 available as solid-state. For all 83 Counters, the solid-state outputs are available in a choice of NPN current sinking or PNP current sourcing, open- collector transistor outputs. All relay output boards are field replaceable.
Prescaler output is available as a dual preset, with solid-state outputs. The prescaler output is useful for providing a lower frequency scaled pulse train to a PLC or another external totalizer. The prescaler output provides a programmable width for every count or every 10 counts registered on the display
RS485 communications - optional serial communication capability allows for interrogation and modification of the preset, count and prescaler values.
Construction - The unit is made of lightweight, high impact plastic with a textured front panel and a clear display window. The front panel meets NEMA4X/IP65 specifications when properly installed. Multiple units can be stacked horizontally or vertically. SMT, extensive testing, plus high immunity to noise interference make the 83 Counter extremely reliable in industrial environments.
## **Features**
## **Options**
- Quadrature sensing • Output type
- • Bidirectional counting, up/down control • Serial communications • Count values to (999999) • Voltage input • Prescaler output model (dual preset only) • Display color • Field replaceable relay output boards • Number of presets • Solid State and relay output models • NEMA4X/IP65 sealed bezel • Status indicators for outputs • Security via programmable operator access privileges and protected values menu
- Programmable user inputs and front panel function key
- Horizontal or vertical stacking of multiple units
- 85 to 250VAC or 18 to 36VDC/24 VAC power units
- RS485 communications option
- Choice of numeric data entry modes
**www.redingtoncounters.com**
**89**
**LCD Predetermining Counter**
**Model 83**
**Electronic**
**Display:** 2 line by 6 digits LCD display **,** negative image transmissive with RED (top line) and GREEN (bottom line) backlighting. Positive image reflective display units are non-stock available. **Main:** 0.3" (7.6mm) high digits **Secondary:** 0.2" (5mm) high digits **Annunciators: Value** : PRS, 1,2 and 3 **Output** : 01, 02 and 03
## **POWER REQUIREMENTS** : **AC Versions**
**AC Power:** 85 to 250 VAC, 50/60Hz, 9VA max. **DC Power:** 11 to 14 VDC @ 159 mA max. (Non PNP output models)
_Note: Models with PNP current sourcing outputs must be powered from AC_
## **DC Versions**
**DC Power:** 18 to 36 VDC: 5.5 W max.
**AC Power:** 24 VAC +/- 10%: 50/60 Hz: 7VA max.
**6. MAX. COUNT RATE:** Model dependent. All listed values are in Khz. Note: Max. count rates for X2 & X4 modes are given for 50% duty cycle signals and quad signals with 90° phase shift.
## **Single Preset Model 8301**
|Prescaler C1-Usr C2-usr *Ad-sub QUAD<br>Value C1-Ud C2-Ud Ad-Ad X1 X2 X4|Prescaler C1-Usr C2-usr *Ad-sub QUAD<br>Value C1-Ud C2-Ud Ad-Ad X1 X2 X4|Prescaler C1-Usr C2-usr *Ad-sub QUAD<br>Value C1-Ud C2-Ud Ad-Ad X1 X2 X4|Prescaler C1-Usr C2-usr *Ad-sub QUAD<br>Value C1-Ud C2-Ud Ad-Ad X1 X2 X4|Prescaler C1-Usr C2-usr *Ad-sub QUAD|Prescaler C1-Usr C2-usr *Ad-sub QUAD|Prescaler C1-Usr C2-usr *Ad-sub QUAD|
|---|---|---|---|---|---|---|
|||||Value C1-Ud C2-Ud Ad-Ad X1 X2 X4|Value C1-Ud C2-Ud Ad-Ad X1 X2 X4|Value C1-Ud C2-Ud Ad-Ad X1 X2 X4|
|0.00001-0.99999|8.4|4.1|9.4|5.4|4.5|2.1|
|1.00000|12.0|5.9|12.4|6.5|6.0|3.0|
|1.00001-2|6.6|3.2|6.8|4.3|3.3|1.6|
|2.00001-3|5.3|2.6|5.6|3.7|2.6|1.3|
|3.00001-4|4.3|2.1|4.6|3|2.2|1.1|
|4.00001-5|3.6|1.8|3.8|2.7|1.8|0.9|
|5.00001-6|3.1|1.5|3.4|2.4|1.6|0.8|
|6.00001-7|2.8|1.4|3.2|2.1|1.4|0.7|
|7.00001-8|2.6|1.3|2.8|1.9|1.3|0.6|
|8.00001-9|2.3|1.1|2.4|1.8|1.1|0.5|
|9.00001-9.99999|2.1|1.0|2.3|1.7|1.1|0.5|
_Note: The 10% tolerance range on AC input voltage must be strictly adhered to DO NOT EXCEED 26.4 VAC_
## **Dual Preset Model 8302**
## **PEAK (START-UP CURRENT)**
- **AC or DC Power:** 500mA peak start-up current for 10 msec. max.
## **DC OUT/ VSCR IN-terminal 10**
For units that do not have PNP current sourcing outputs, this terminal provides a DC output for sensor power + 12 VDC (+/- 15%). The maximum sensor current is 100mA.
For units with PNP current sourcing outputs this terminal serves a dual purpose depending on the application PNP output voltage level and current requirements.
1. The terminal may be used as a +12 VDC output for sensor power. In this case, the PNP output voltage level will be +12 VDC (+/-15%). A maximum of 100 mA is available for the combination of sensor and PNP output sourcing current.
2. If a higher PNP output voltage level or additional output sourcing current is needed, an external DC supply may be connected between the _“DC OUT_ ( V SRC IN)” and _“COMM_ .” terminals. This supply will determine the PNP output voltage level, and must be in the same range of +13 to +30 VDC.
An external DC supply can also provide the additional output sourcing current required in applications where two or more PNP outputs are “ON” simultaneously. However, the maximum current range of 100mA per individual output must not be exceeded, regardless of external supply capacity.
**3. Memory:** Nonvolatile FRAM retains all program parameters and count values.
**4. SENSOR POWER:** + 12 VDC (+/- 15%) @ 100mA max.
**5. COUNT INPUTS A & B:** Accepts count pulses from a variety of sources, DIP switch selectable.
**Current Sourcing: (active high):** Vinmax. = 3.9K ohm pull-down to 30 VDC.
**Current Sinking: (active low):** 7.8 K ohm pull-up to 12 VDC : Isnk = 1.8mA max.
**Debounce :** 50 Hz **Lo Bias:** VIL = 1.5 VDC max., VIH = 3.75 VDC min. **Hi Bias:** VIL = 5.5 VDC max., VIH = 7.5 VDC min.
|Prescaler C1-Usr C2-usr *Ad-sub QUAD<br>Value C1-Ud C2-Ud Ad-Ad X1 X2 X4|Prescaler C1-Usr C2-usr *Ad-sub QUAD<br>Value C1-Ud C2-Ud Ad-Ad X1 X2 X4|Prescaler C1-Usr C2-usr *Ad-sub QUAD<br>Value C1-Ud C2-Ud Ad-Ad X1 X2 X4|Prescaler C1-Usr C2-usr *Ad-sub QUAD<br>Value C1-Ud C2-Ud Ad-Ad X1 X2 X4|Prescaler C1-Usr C2-usr *Ad-sub QUAD|Prescaler C1-Usr C2-usr *Ad-sub QUAD|Prescaler C1-Usr C2-usr *Ad-sub QUAD|
|---|---|---|---|---|---|---|
|||||Value C1-Ud C2-Ud Ad-Ad X1 X2 X4|Value C1-Ud C2-Ud Ad-Ad X1 X2 X4|Value C1-Ud C2-Ud Ad-Ad X1 X2 X4|
|0.00001-0.99999|8.3|4.1|8.6|4.5|4.1|2.1|
|1.00000|11.5|5.7|11.5|6.0|5.8|3.0|
|1.00000<br>1.00001-2|11.5<br>6.5|5.7<br>3.2|11.5<br>6.6|6.0<br>4.0|5.8<br>3.2|3.0<br>1.6|
|1.00001-2<br>2.00001-3|6.5<br>5.0|3.2<br>2.4|6.6<br>5.2|4.0<br>3.4|3.2<br>2.5|1.6<br>1.3|
|3.00001-4|4.1|2.0|4.4|2.8|2.0|1.0|
|4.00001-5|3.4|1.7|3.8|2.5|1.7|0.8|
|5.00001-6|2.9|1.4|3.2|2.2|1.4|0.7|
|6.00001-7|2.7|1.3|2.8|2.0|1.3|0.6|
|7.00001-8|2.2|1.1|2.4|1.8|1.2|0.6|
|8.00001-9|2.2|0.9|2.3|1.6|1.1|0.5|
|9.00001-9.99999|1.9|0.9|2.0|1.5|0.9|0.4|
## **Batch Model 8303**
With Counter 2 configured as a Batch Counter ( _C2 A5n = bAtch_ )
|Prescaler C1-Usr C2-usr *Ad-sub QUAD<br>Value C1-Ud C2-Ud Ad-Ad X1 X2 X4|Prescaler C1-Usr C2-usr *Ad-sub QUAD<br>Value C1-Ud C2-Ud Ad-Ad X1 X2 X4|Prescaler C1-Usr C2-usr *Ad-sub QUAD<br>Value C1-Ud C2-Ud Ad-Ad X1 X2 X4|Prescaler C1-Usr C2-usr *Ad-sub QUAD<br>Value C1-Ud C2-Ud Ad-Ad X1 X2 X4|Prescaler C1-Usr C2-usr *Ad-sub QUAD|Prescaler C1-Usr C2-usr *Ad-sub QUAD|Prescaler C1-Usr C2-usr *Ad-sub QUAD|
|---|---|---|---|---|---|---|
|||||Value C1-Ud C2-Ud Ad-Ad X1 X2 X4|Value C1-Ud C2-Ud Ad-Ad X1 X2 X4|Value C1-Ud C2-Ud Ad-Ad X1 X2 X4|
|0.00001-0.99999|8.3|4.1|8.4|3.7|3.6|2.2|
|1.00000|11.4|5.5|11.8|4.3|4.2|3.0|
|1.00000<br>1.00001-2|11.4<br>6.5|5.5<br>3.2|11.8<br>6.6|4.3<br>3.2|4.2<br>3.0|3.0<br>1.6|
|1.00001-2<br>2.00001-3|6.5<br>5.0|3.2<br>2.5|6.6<br>5.4|3.2<br>2.8|3.0<br>2.5|1.6<br>1.3|
|3.00001-4|4.1|2.0|4.2|2.4|2.0|1.0|
|4.00001-5|3.4|1.7|3.8|2.1|1.7|0.8|
|5.00001-6|2.9|1.4|3.2|1.9|1.5|0.7|
|6.00001-7|2.7|1.3|2.8|1.7|1.3|0.6|
|7.00001-8|2.4|1.1|2.6|1.6|1.2|0.6|
|8.00001-9|2.2|1.1|2.4|1.5|1.1|0.5|
|9.00001-9.99999|1.9|0.9|2.2|1.4|1.0|0.4|
## **Batch Model 8303**
With Counter 2 configured as a Total Counter ( _C2 A5n = totAL_ ) Prescaler C1-Usr C2-usr *Ad-sub QUAD Value C1-Ud C2-Ud Ad-Ad X1 X2 X4 0.00001-0.99999 6.5 3.3 6.6 3.5 3.3 1.6 ——{——=== 1.00000 8.5 3.6 8.6 4.0 4.0 2.1 **Prescaler Output Model 8304** Prescaler C1-Usr C2-usr *Ad-sub QUAD Value C1-Ud C2-Ud Ad-Ad X1 X2 X4 0.00001-0.99999 6.2 N/A N/A N/A N/A N/A =a 1.00000 8.0 N/A N/A N/A N/A N/A * _Inputs A & B rates summed._
**www.redingtoncounters.com**
**90**
am **Model 83**
**LCD Predetermining Counter**
## **Electronic**
**7. USER INPUTS:** Configurable as current sinking (active low), or current sourcing (active high) inputs via a single plug jumper.
- **Current Sinking: (active low) :** VIL= 1.5 VDC max. 22 K ohm pull-ups to 5 VDC
- **Current Sourcing: (active high):** VIH =3.5 min. VIN max. = 30 VDC; 22K ohm pull-down.
**Response Time:** 10 msec. max.
**Inhibit Response Time:** 250 microsec max.
**8. OUTPUTS:** (Output type and quantity model dependent) **Solid-State:**
**NPN Open Collector:** ISNK **=** 100mA max. @ VOL = 1.1 VDC max. ;VOH= 30 VDC max.
**PNP Open Collector:** ISRC = 100mA max. ( See note) ; VOH = 12 VDC +/-15% ( using internal supply); VOH = 13 to 30 VDC ( using external supply).
_Note: The internal supply of the 83 counter can provide a total of 100 mA for the combination of sensor current and PNP output sourcing current. The supply voltage is +12 VDC (+/-15 %), which will be the PNP output voltage level when using only the internal supply._
_If additional PNP output sourcing current or a higher output voltage level is desired, an external DC supply may be connected between the “DC Out/In” and “Comm” terminals. This supply will determine the PNP output voltage level, and must be in range of +13 to 30 VDC._
_An external supply can provide the additional output sourcing current required in applications where two or more outputs are_ _**“** ON_ _**”** simultaneously. However, the maximum rating of 100mA per individual output must not be exceeded, regardless of external supply capacity._
**Relay:** Form A contact, rating = 5 A @ 250 VAC, 30 VDC (resistive load) , 1/10 HP @ 120 VAC (inductive load).
**Relay Life Expectancy:** 100,000 cycles min. at max. load rating. **Programmable Timed Output:** User selectable output time resolutions.
**0.01 Second Resolution:** 0.01 to 99.99 sec., +/-0.01% +20 msec max. (Prescalers less than 2) **0.1 Second Resolution:** 0.1 to 999.9 sec. +/- 0.01 + 100 msec max. (Prescalers less than 2)
**9. RS485 SERIAL COMMUNICATIONS (Optional):** Up to 32 units can be connected.
**Baud Rate:** Programmable from 1200 to 9600 baud. **Address:** Programmable from 0 to 99. **Data Format:** 10 Bit Frame, 1 start bit , 7 or 8 data bits, 1 or no Parity bit, and 1 stop bit. **Parity:** Programmable for Odd (7 data bits), Even ( 7 data bits) or None ( 8 data bits).
## **11. ENVIRONMENTAL CONDITIONS:**
**Operating Temperature:** +32°F to +122°F [0°C TO +50°C] **Storage Temperature:** 40°F to +158°F [-40°C to +70°C] **Operating and Storage Humidity:** 85% max. relative humidity (
- +32°F to +122°F [0°C TO +50°C] **-** 40°F to +158°F [-40°C to +70°C]
non-condensing) from +32°F to +122°F [0°C to +50°C]
**Altitude :** Up to 6500 Feet [1981 Meters]
**12. ELECTRICAL CONNECTIONS:** Wire clamping screw terminals.
**13. CONSTRUCTION:** Black plastic case with collar style panel latch. The panel latch can be installed for horizontal or vertical stacking. Black plastic textured bezel can be removed from the case without removing the case from the panel or disconnecting the wiring. Front panel meets NEMA4X/IP65 requirements for indoor use, when properly installed. Installation Category II, Pollution Degree 2.
**14. WEIGHT:** 6.0 oz [170g]
## **SINGLE PRESET MODELS**
The 8301 has a solid-state output that operates in parallel with a relay output. The solid-state output is available as an NPN or PNP open collector transistor.
## **DUAL PRESET MODELS**
The 8302 has two outputs that are activated from presets 1 and 2. These outputs can be relay or solid-state outputs. The solid-state outputs are available as NPN or PNP open-collector transistors. Units with solid-state outputs can be ordered with an optional prescaler output.
## **3 PRESET BATCH MODELS**
The 8303 has a secondary counter that can be used for batch counting, or to keep a total count. This second counter can be programmed to operate in one of eight operating modes. Output 1 and 2 are assigned to the primary process counter (C1). Output 3 is assigned to the secondary Batch/Total counter (C2). The three preset batch unit can be ordered with solid-state or relay outputs. Units with solid-state outputs have a User Input 2 terminal available. The relay model has a relay output for Output 2 and Output 3 (Batch/Total). Output 1 is available only as solid-state.
## **PRESCALER OUTPUT MODELS**
The 8304 is a dual preset counter with solid-state outputs. These models have an additional output configured as a prescaler output. Each time the least significant digit of the display increments, the Prescaler output provides a pulse. The width of this pulse is variable in that the output will turn off after a programmed number of count input pulses has occurred (1-9). The Prescaler output can also be programmed to activate when the 10’s digit of the display increments, rather than the least significant digit.
_**Note:** Prescaler Output Models are limited to two programmable count modes and prescaler values of 1.00000 or less. See Count Input Modes for available modes._
## **FRONT PANEL KEYPAD**
## **10. CERTIFICATIONS AND COMPLIANCES: UL Recognized Component, File # E195514**
Recognized to U.S. and Canadian requirements under the Component Recognition Program of Underwriters Laboratories, Inc.
## **CE Compliant:**
ELECTROMAGNETIC COMPATIBILITY
**Immunity to EN 50082-2** electrostatic discharge EN 61000-4-2 electromagnetic RF fields EN 61000-4-3 fast transients EN 61000-4-4 RF conducted interference EN 61000-4-6 simulation of cordless phone EN V502204 Emissions to EN 50081-2 RF interference EN 55011 enclosure class A
- Performs user Programmed Function.
- Cycles through secondary displays.
- Enters Programming Mode or Protected Value Menu when pushed and held for 2 seconds.
- Scrolls through programming displays.
- Enters Data Values.
- Selects next available mode in programming mode.
- Increments digit in digit Entry mode.
- Increments value in Auto Scrolling entry mode.
- Selects Digit to right when in Digit Entry mode.
- Decrements value in Auto Scrolling entry mode.
**www.redingtoncounters.com**
**91**
| | **Model 83**
**LCD Predetermining Counter**
**Electronic**
## **Models Description**
For Details on Models and Descriptions, see the Ordering Information section
## **Dimensions**
## **MULTIPLE UNIT STACKING**
The Model 83 is designed for close spacing of multiple units. Units can be stacked either horizontally or vertically. For vertical stacking, install the panel latch with screws to the sides of the unit. For horizontal stacking, the panel latch screws should be at the top and bottom of the unit. The minimum spacing from center line to center line of the units is 1.96” (49.8 mm). This spacing is the same for vertical or horizontal stacking.
_Note: When stacking units, provide adequate panel ventilation to ensure that the maximum operating temperature range is not exceeded._
**==> picture [217 x 62] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.96 [49.8]<br>2.39 [60.7] MAX.<br>MAX.<br>al Is a e hs!<br>e er pelea<br>1.96 [49.8] 2.39 [60.7]<br>MAX. MAX.<br>**----- End of picture text -----**<br>
## **PANEL CUTOUT SPACING FOR MULTIPLE UNIT STACKING. HORIZONTAL ARRANGEMENT SHOWN.**
**==> picture [22 x 24] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.96<br>(49.8)<br>MIN<br>**----- End of picture text -----**<br>
PANEL LATCH INSTALLED FOR PANEL LATCH INSTALLED FOR VERTICAL UNIT STACKING HORIZONTAL UNIT STACKING
IF NEMA 4 IS NOT REQUIRED, THIS PANEL MATERIAL MAY BE REMOVED.
## **Applications**
Converting
**==> picture [35 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
Batching<br>**----- End of picture text -----**<br>
Cut-to-length
Packaging
**www.redingtoncounters.com**
**92**
**LCD Predetermining Counter**
**Model 83**
**Electronic**
## **Ordering Information**
|MODEL NO.|DESCRIPTION|NPN O.C.|*PNP O.C.|RELAY|RS485|PART NUMBERS FOR AVAILABLE|PART NUMBERS FOR AVAILABLE|
|---|---|---|---|---|---|---|---|
|||OUTPUT(S)|OUTPUT(S)|OUTPUT(S)||SUPPLY VOLTAGES||
|||||||18-36 VDC/24 VAC 85 TO 250 VAC|85 TO 250 VAC|
|8301|1 Preset Counter|Yes|No|Yes|No|**8301-0110**|**8301-1110**|
||Backlit LCD|||||||
||2 Preset Counter<br>Backlit LCD|Yes|No|No|No|**8302-0100**|8302-1100|
|8302|2 Preset Counter<br>Backlit LCD|Yes|No|No|Yes|**8302-0101**|**8302-1101**|
||2 Preset Counter<br>Backlit LCD|No|No|Yes|No|**8302-0010**|**8302-1010**|
||2 Preset Counter<br>Backlit LCD|No|No|Yes|Yes|**8302-0011**|**8302-1011**|
||2 Preset Counter|||||||
||w/Prescaler Output|Yes|No|No|No|**8304-0100**|**8304-1100**|
|8304|Backlit LCD|||||||
||2 Preset Counter|||||||
||w/Prescaler Output|Yes|No|No|Yes|**8304-0101**|**8304-1101**|
||Backlit LCD|||||||
|3 Preset Batch<br>Counter<br>Yes(01)<br>No<br>Yes<br>No<br>**8303-0110**<br>**8303-1110**<br>Backlit LCD<br>3 Preset Batch<br>Counter<br>Yes(01)<br>No<br>Yes<br>Yes<br>**8303-0111**<br>**8303-1111**<br>8303<br>Backlit LCD<br>3 Preset Batch<br>Counter<br>Yes<br>No<br>No<br>No<br>**8303-0100**<br>**8303-1100**<br>Backlit LCD<br>3 Preset Batch<br>Counter<br>Yes<br>No<br>No<br>Yes<br>**8303-0101**<br>**8303-1101**<br>Backlit LCD<br>ESSS=5==||||||||
_Note: On batch Relay Models, Outputs 2 and 3 are relays, and Output 1 (01) is a solid-state output._
- PNP outputs are non-stock items
- Items in bold are normally in factory stock.
**RELAY OUTPUT BOARDS**
DESCRIPTION NPN O.C. * PNP O.C. RELAY PART NUMBER Single Preset Yes No Yes 1726-044S Dual Preset No No Yes 1726-045S Batch Yes No Yes 1726-046S ~~=~~
**www.redingtoncounters.com**
**93**
| | **Model 83**
**LCD Predetermining Timer**
**Electronic**
## **Description**
The Model 83 Timer is available in single or dual preset models. The 83 Timer features a 7 segment, 2 lines by 6-digit backlit LCD display. The main display line is red and shows the timer value. The smaller secondary display line is green and can be used to view the preset values or output time values.
The 83 Timer can be configured for a variety of different operating modes to meet most timing application requirements. Twelve timing ranges are available from thousands of a second to hours and minutes. Decimal points are used to separate the time units (hours, minutes, seconds). Timing can be cumulative or can reset and start upon each power cycle. “on delay” or “off delay”, “single shot”, “repetitive auto cycling” modes are all supported.
The 83 Timer can also be configured to continue or stop timing upon reaching preset. The display can be programmed to stop at the preset value (reset to zero mode) or zero (reset to preset mode), or automatically reset to zero or preset and hold. Once stopped, the timer can be restarted by manually resetting it, or it can be programmed to restart when power is reapplied. The 83 Timer has a run/stop input, 3 programmable user inputs, and a programmable front panel function key. The run/stop and user inputs can be configured as sinking (active low) or sourcing (active high) inputs via a single plug jumper. The user inputs and the front panel function key can be configured to provide a variety of functions.
Four front panel push-buttons are used for ease of programming the operating modes and data values, changing the viewed display, and performing user programmable functions, e.g. reset, etc. The 83 Timer can be configured for one of two numeric data entry methods digit or automatic scrolling.
Digital - The digital entry allows for the selection and incrementing of digits individually.
Automatic scrolling - This method allows for the progressive change of one through all digits positions by pressing and holding the **up** or **down** button.
The dual preset models are available with solid-state or relay outputs. The single preset model has a solid-state and relay output in parallel. All solid-state outputs are available in a choice of NPN current sinking or PNP current sourcing, open- collector transistor outputs. All relay output boards are field replaceable.
RS485 communications - optional serial communication capability allows for interrogation and modification of the preset, and timer values.
Construction- The unit is made of lightweight, high impact plastic with a textured front panel and a clear display window. The front panel meets NEMA4X/IP65 specifications when properly installed. Multiple units can be stacked horizontally or vertically. SMT, extensive testing, plus high immunity to noise interference make the 83 Timer extremely reliable in industrial environments.
- **Features Options** • Displays values to (999999) • Output type • 12 timing ranges • Serial communications • Field replaceable relay output boards • Voltage input • Solid state and relay output models • Display color • NEMA4X/IP65 sealed bezel • Number of presets • Status indicators for outputs
- Security via programmable operator access privileges and protected values menu
- Programmable user inputs and front panel function key
- Horizontal or vertical stacking of multiple units
- 85 to 250VAC or 18 to 36VDC/24 VAC power units
- RS485 communications option
- Choice of numeric data entry modes
**www.redingtoncounters.com**
**94**
**LCD Predetermining Timer**
**Model 83**
**Electronic**
## **Specifications**
**Display:** 2 line by 6 digits LCD display **,** negative image transmissive with RED (top line) and GREEN (bottom line) backlighting. Positive image reflective display units are non-stock available. **Main:** 0.3" (7.6mm) high digits **Secondary:** 0.2" (5mm) high digits **Annunciators: Value** : PRS, 1, and 2 **Output** : 01 and 02
## **POWER REQUIREMENTS** : **AC Versions**
**AC Power:** 85 to 250 VAC, 50/60Hz, 9VA max. **DC power:** 11 to 14 VDC @ 159 mA max. (Non PNP output models)
_Note: Models with PNP current sourcing outputs must be powered from AC_
## **DC Versions**
**DC Power:** 18 to 36 VDC: 5.5 W max. **AC Power:** 24 VAC +/- 10%: 50/60 Hz: 7VA max. _Note: The 10% tolerance range on AC input voltage must be strictly adhered to> DO NOT EXCEED 26.4 VAC_
## **PEAK (START-UP CURRENT)**
**AC or DC Power:** 500mA peak start-up current for 10 msec. max.
## **DC OUT/ VSCR IN-terminal 10**
For units that do not have PNP current sourcing outputs, this terminal provides a DC output for sensor power (+ 12 VDC +/-15%). The maximum sensor current is 100mA. For units with PNP current sourcing outputs this terminal serves a dual purpose depending on the application PNP output voltage level and current requirements.
1. The terminal may be used as a +12 VDC output for sensor power. In this case, the PNP output voltage level will be +12 VDC (+/-15%). A maximum of 100 mA is available for the combination of sensor and PNP output sourcing current.
2. If a higher PNP output voltage level or additional output sourcing current is needed, an external DC supply may be connected between the _“DC OUT”_ ( V SRC IN) and _“COMM_ .” terminals. This supply will determine the PNP output voltage level, and must be in the same range of +13 to +30 VDC.
An external DC supply can also provide the additional output sourcing current required in applications where two or more PNP outputs are “ON” simultaneously. However, the maximum current range of 100mA per individual output must not be exceeded, regardless of external supply capacity.
## **6. TIME ACCURACY:** +/- 0.01%
**7. OUTPUTS:** ( Output type and quantity model dependent) **Solid-State:**
## **NPN Open Collector:**
ISNK **=** 100mA max. @ VOL = 1.1 VDC max.; VOH = 30 VDC max.
## **PNP Open Collector:**
ISRC = 100mA max. ( See note) ; VOH = 12 VDC +/-15% ( using internal supply); VOH = 13 to 30 VDC ( using external supply).
_Note: The internal supply of the 83 Timer can provide a total of 100 mA for the combination of sensor current and PNP output sourcing current. The supply voltage is +12 VDC (+/-5 %), which will be the PNP output voltage level when using only the internal supply._
_If additional PNP output sourcing current or a higher output voltage level is desired, an external DC supply may be connected between the “ DC Out/In” and “Comm” terminals. This supply will determine the PNP output voltage level, and must be in range of +13 to 30 VDC._
_An external supply can provide the additional output sourcing current required in applications where two or more outputs are_ _**“ON”** simultaneously. However, the maximum rating of 100mA per individual output must not be exceeded, regardless of external supply capacity._
**Relay:** Form A contact, rating = 5 A @ 250 VAC, 30 VDC (resistive load) 1/10 HP @ 120 VAC (inductive load). **Relay Life Expectancy:**
100,000 cycles min. at max. load rating. **Programmable Timed Output:**
User selectable output time resolutions. **0.01 Second Resolution:** 0.01 to 99.99 sec., +/0.01% +10 msec max.
**0.1 Second Resolution:** 0.1 to 999.9 sec. +/- 0.01
% +100 msec max.
## **8. RS485 SERIAL COMMUNICATIONS (Optional):**
- Up to 32 units can be connected.
- **Baud Rate:** Programmable from 1200 to 9600 baud. **Address:** Programmable from 0 to 99
**Data Format:** 10 Bit Frame, 1 start bit , 7 or 8 data bits, 1 or no Parity bit, and 1 stop bit.
**Parity:** Programmable for Odd (7 data bits), Even ( 7 data bits) or None ( 8 data bits).
**9. CERTIFICATIONS AND COMPLIANCES: UL Recognized Component, File # E195514**
Recognized to U.S. and Canadian requirements under the Component Recognition Program of Underwriters Laboratories, Inc.
## **CE COMPLIANT :**
**3. MEMORY:** Nonvolatile FRAM retains all program parameters and Timer values.
**4. SENSOR POWER:** +12 VDC (+/- 15%) @ 100mA max.
**5. INPUTS:** Run/Stop, Usr. In1, Usr. In2, and Usr. In3.
- Configurable as current sinking (active low), or current sourcing (active high) inputs via a single plug jumper.
## **Current Sinking: (active low) :**
VIL = 1.5 VDC max. 22 K ohm pull-ups to 5 VDC **Current Sourcing: (active high):** VIH = 3.5 min. VIN max. = 30 VDC; 22K ohm pull-down. **Run/Stop Response Time :** 250 microseconds max.
**User Input Response Time:** 5 msec. max.
ELECTROMAGNETIC COMPATIBILITY
**Immunity to EN 50082-2** electrostatic discharge EN 61000-4-2 electromagnetic RF fields EN 61000-4-3 fast transients EN 61000-4-4 RF conducted interference EN 61000-4-6 simulation of cordless phone ENV50204
**Emissions to EN 50081-2** RF interference EN 55011 enclosure class A
## **10. ENVIRONMENTAL CONDITIONS:**
**Operating Temperature:** +32°F to +122°F [0°C to +50°C] **Storage Temperature: -** 40°F to +158°F [-40°C to +70°C]
**www.redingtoncounters.com**
**95**
| | **Model 83**
**LCD Predetermining Timer**
## **Electronic**
## **Operating and Storage Humidity:**
85% max. relative humidity ( non-condensing) from +32°F to +122°F [0°C to +50°C] **Altitude:** Up to 6500 Feet
## **11. ELECTRICAL CONNECTIONS:**
Wire clamping screw terminals.
**12. CONSTRUCTION:** Black plastic case with collar style panel latch. The panel latch can be installed for horizontal or vertical stacking. Black plastic textured bezel can be removed from the case without removing the case from the panel or disconnecting the wiring. Front panel meets NEMA4X/IP65 requirements for indoor use, when properly installed. Installation Category II, Pollution Degree 2.
**13. WEIGHT:** 6.0 oz [170g]
## **SINGLE PRESET MODELS**
The 8321 Timer offers a choice of twelve timing ranges with eighteen different operating modes. The unit has a solid-state output that operates in parallel with a relay output. The solid-state output is available as an NPN or PNP open collector transistor.
## **DUAL PRESET MODELS**
The 8322 Timer offers a choice of twelve timing ranges with 44 operating modes. The unit is available with solid-state or relay outputs. The solidstate outputs are available as NPN or PNP open collector transistors.
## **Models Description**
For Details on Models and Descriptions, see the Ordering Information section
## **Dimensions**
## **MULTIPLE UNIT STACKING**
The Model 83 is designed for close spacing of multiple units. Units can be stacked either horizontally or vertically. For vertical stacking, install the panel latch with screws to the sides of the unit. For horizontal stacking, the panel latch screws should be at the top and bottom of the unit. The minimum spacing from center line to center line of the units is 1.96” (49.8 mm). This spacing is the same for vertical or horizontal stacking.
_Note: When stacking units, provide adequate panel ventilation to ensure that the maximum operating temperature range is not exceeded._
**==> picture [564 x 139] intentionally omitted <==**
**----- Start of picture text -----**<br>
PANEL CUTOUT SPACING FOR MULTIPLE UNIT STACKING.<br>HORIZONTAL ARRANGEMENT SHOWN.<br>_ 2.39 [60.7] 1.96 [49.8]MAX. 1.96<br>MAX. F1 (49.8)<br>MIN<br>| -<br>Be ge ee\ | TR S 7 5<br>reer 1.96 [49.8] Sen 2.39 [60.7] Z f<br>MAX. MAX.<br>oa ||Ene |: a : :<br>ogee tise el<br>fee Ben/—| aed HH<br>PANEL LATCH INSTALLED FOR PANEL LATCH INSTALLED FOR Ee 7 IF NEMA 4 IS NOT REQUIRED,<br>VERTICAL UNIT STACKING HORIZONTAL UNIT STACKING THIS PANEL MATERIAL MAY BE REMOVED.<br>**----- End of picture text -----**<br>
## **Applications**
Mixing
**==> picture [86 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
Volumetric measurement<br>**----- End of picture text -----**<br>
**==> picture [47 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
Batch Control<br>**----- End of picture text -----**<br>
**www.redingtoncounters.com**
**96**
**LCD Predetermining Timer**
**Model 83**
**Electronic**
## **Ordering Information**
|MODEL NO.|DESCRIPTION|NPN O.C.<br>OUTPUT(S) OUTPUT(S)|* PNP O.C.<br>OUTPUT(S) OUTPUT(S)|RELAY<br>OUTPUT(S)|RS485|PART NUMBERS FOR AVAILABLE<br>SUPPLY VOLTAGES|PART NUMBERS FOR AVAILABLE<br>SUPPLY VOLTAGES|
|---|---|---|---|---|---|---|---|
|8321|1 Preset Timer<br>Backlit LCD|OUTPUT(S) OUTPUT(S)<br>Yes|OUTPUT(S) OUTPUT(S)<br>No|OUTPUT(S)<br>Yes|No|18-36 VDC/24 VAC|85 TO 250 VAC|
|||||||8321-0110|**8321-1110**|
|8322|2 Preset Timer<br>Backlit LCD|No|No|Yes|No|**8322-0010**|**8322-1010**|
||2 Preset Timer<br>Backlit LCD|No|No|Yes|Yes|**8322-0011**|**8322-1011**|
||2 Preset Timer<br>Backlit LCD|Yes|No|No|No|**8322-0100**|**8322-1100**|
||2 Preset Timer<br>Backlit LCD|Yes|No|No|Yes|8322-0101|**8322-1101**|
- PNP Outputs are non-stock items
- Items in bold are normally in factory stock.
## **RELAY OUTPUT BOARDS**
|DESCRIPTION|NPN O.C.|* PNP O.C.|RELAY|PART NUMBER|
|---|---|---|---|---|
|Single Preset|Yes|No|Yes|1726-044S|
|Single Preset<br>Dual Preset|No|No|Yes|1726-045S|
|3 Preset|Yes|No|Yes|1726-046S|
- PNP Outputs are non-stock items
**www.redingtoncounters.com**
**97**
|} **Model 92**
**Hand Held Tachometer**
**Electronic**
## **Description**
The Redington Model 9200-HTK hand tachometer kit combines low cost with convenience. Simple to use… push the measurement button to record the speed. The tachometer can be used for contact or non-contact measurement on rotating machinery or surface speed. The photoelectric probe is used with reflective tape to detect rotating objects. The accessory adaptor with pointed tip can be added for contact measurement or wheels can be used for surface speed measurement. For measuring in tight or confined spaces, an optional remote sensor is available.
## **Features**
## **Options**
• Combination unit - photo and contact • Remote sensor for measurement in hard to reach places
- Wide speed range - 6.0 - 99,999.9 RPM, 0.1 resolution
- Sampling time of 1-10 seconds
- Automatic shutoff after 3 minutes
- Digital display with low battery alarm and reflective light input indicator
- Carrying case included
## **Specifications**
**Power Source:** 4 alkaline batteries (AAA, 1.5 V) **Automatic Power Cutoff:** After 3 minutes from last measurement. continuous measurement 20 hours. **Display:** 6 digit LCD **Accuracy:** ± 0.01% ± 1 digit RPM f/min. (others ± **Approvals:** CE Compliant, passed EMC tests EMI: 0.05% or ± 1 digit including tolerance for EN50081-1 & EMS: EN50082-1 conversion). **Weight:** 7 oz [199g] (with in-line contact **Measurement Distance:** 2”-14” (50-300mm) with reflective tape. adaptor). **Measurement Range:** 6.0 - 99,999.9 RPM **Operating Temperature:** +41°F to +104°F [+5°C to +40°C] **Sampling Time:** 1.0-10.2 sec.
|**Models**|**Description**|**Models**|**Description**|
|---|---|---|---|
|**9200-HTK**|Hand Tachometer Kit: includes, Hand Tach. (Photo), In-|9200-HT|Hand Held Tachometer|
||Contact adaptor, Rubber tips (3), Reflective Tape (10|**1887-021S**|Remote Probe|
||sheets), Surface Speed wheels, 1 ea. (1/10 m/min., and|**1895-004S**|Rubber Tips|
||1/10 yd./min.), Carrying Case, Batteries (4 AAA size, 1.5|**1895-005S**|Surface Wheel (1/10 Meter)|
||V, Instructions Manual).|**1895-006S**|Surface Wheel (1/10 Yard)|
|||**200507-046S**|Reflective Tape (10 Sheets)|
* Items in bold are normally in factory stock.
**www.redingtoncounters.com**
**98**
|} **Model 92**
**Hand Held Tachometer**
**Electronic**
## **Dimensions**
**==> picture [179 x 261] intentionally omitted <==**
**----- Start of picture text -----**<br>
4.78<br>[121.4]<br>2.27<br>[57.7]<br>l l ]<br>6.93<br>[176.0]<br>2.41<br>[61.1]<br>**----- End of picture text -----**<br>
## **Applications**
Speed of many rotating objects
Check motor speeds
Conveyor line speed
**www.redingtoncounters.com**
**99**
it **Model 65**
**Encoder**
**Standard Industrial Rotary Pulse Generator**
## **Description**
These versatile, dependable and rugged encoders are ideal for use with electronic counters, PLC’s, motion controllers and motor drives. A wide selection of resolutions (Pulse Per Revolution, PPR) makes the Model 65 ideal for a wide variety of applications. The sealed aluminum housing offers greater protection from wash down, sprays, dust, moisture, shock and other hazards found in industrial environments.
## **Features**
- Quadrature or unidirectional output
- 3/8" [9.5mm] shaft diameter, 303, stainless steel
- Double shaft extension
- NPN transistor output
## **Options**
- Rugged duty housing
- +5 to +28VDC input power
- Wide selection of resolutions
- Heavy duty sealed bearings
- • IP 65 shaft seal
## **Specifications**
**Input:** Voltage: +5 to +28VDC Current: 80mA with no output load **Output:** Current sinking NPN open collector Transistor Single channel, 250mA max quadrature, 250mA max per output. **Connections:** Eurofast connector **Cable /Connector:** (8 pin) RKC 8T2/S618, (Turck P/N) 2 meters long **Housing:** Black non-corrosive finished, aluminum **Max. Shaft Speed:** 6,000 RPM **Frequency Response:** 0-125 kHz **Bearings:** ABEC 3 double sealed shaft ball bearings
**Radial Load:** 40 pounds maximum **Axial Shaft Loading:** 30 pounds maximum **Starting Torque:** 3.00 oz-inches **Moment of Inertia:** 6.5 X 10[6] oz in sec[2] **Mounting:** Tapped mounting holes on three sides for base or face mounting **Weight:** 1lb ([284g] **Operating Temp:** 32°F to 185°F [0°C to 85°C] **Storage Temp:** -13°F to +212°F [-25° to +100°C] **Shock:** 50 g’s @ 100ms duration **Vibration:** 10 g’s @ 58 to 500 cps **Humidity:** 98% RH non-condensing
|**Models**|**Description**|**PPR***|**Models**|**Description**|**PPR***|
|---|---|---|---|---|---|
|6510-0060||60|6520-0010||10|
|6510-0100||100|6520-0012|DUAL CHANNEL|12|
|6510-0600|SINGLE CHANNEL|600|6520-0100|(QUADRATURE)|100|
|6510-1000||1,000|6520-0120||120|
|6510-1200||1,200|6520-0500||500|
|*Only popular PPR’s are listed, other PPR’s are available on special order.|*Only popular PPR’s are listed, other PPR’s are available on special order.||6520-0600||600|
||||RKC 8T2/S618|8 Pin Cable 6' (2 meters) long||
*Only popular PPR’s are listed, other PPR’s are available on special order.
## **Dimensions**
## **Applications**
**==> picture [400 x 137] intentionally omitted <==**
**----- Start of picture text -----**<br>
#6-32 THD X .25 DEEP<br>ON 2.00 [50.8] BOLT CIRCLE<br>BOTH ENDS AND BOTTOM<br>0.83 0.65 [16.5]<br>int [21.0] ~ |<br>Ø.25 [6.4]<br>2.25<br>0.71 [18.0] f @-\ |/; [57.2] 0.03[0.8] e d | = | 1.13 [28.6] |<br>0.50<br>[12.7]<br>——ps 2.25 [57.2] || 0.07 [1.8] |a 2.25 [57.2] 4<br>Measuring Wheel Generating pulses from Generating Quadrature signal for<br>Length sensors idler roll with RPG position from lead screw rotation using<br>RPG<br>**----- End of picture text -----**<br>
**www.redingtoncounters.com**
**100**
| | **Model 65**
**Sensor**
**Proximity Switch**
## **Description**
The Redington Model 65 proximity switch has an all-metal housing, nickel plated brass, compact size and a long operating distance, 1.5 mm. The Model 65 has a NEMA 6 & 6P, IP67 rating. Its all-metal housing and sealing makes it ideal for most extreme environmental conditions. The Model 65 has built - in protection for short-circuit protection, polarity reversal and power on reset.
## **Features**
- Embeddable mounting
- 5,000 Hz switching frequency
- IP 67 rating
## **Models**
## **DW-AD-601-M8**
- Item is normally in factory stock.
- 10-32 VDC operating range
- LED output state indicator
- 8mm diameter
## **Specifications**
**Supply Voltage:** 10-30VDC **Sensing Range:** 0.1’’ [1.5mm] **Sensor Diameter:** 8mm **Connection:** PVC cable 6’ [2m] **Degree of Protection:** IP67 **Mounting:** Embeddable **Max. Switching Frequency:** 5,000 Hz **Out-put Status Indicator:** LED **Out-put Type:** NPN/N.O. output **Built-in Protection:** Short-circuit Polarity reversal Power-on reset
**Permissible Ripple Content:** < 20% **No-load Supply Current:** < 10mA **Output Current:** < 200mA **Leakage Current at Output:** < 0.1mA **Voltage Drop, Switched State:** < 2.0V **Ambient Temperature Range:** -13ºF to 158ºF [-25ºC to 70ºC] **Temperature Drift:** < 10% **Hysteresis% Sr:** 1 to 15% (5% typ.) **Repeat Accuracy:** (IEC 60947-5-2): < 5% Sr **Approvals:** CE Compliant
## **Dimensions**
## **Wiring Diagram**
SW13 0.16 [4.0] Ø.14 [3.5] ~~who~~ M8X1 J LED 1.38 [35.0]
**==> picture [219 x 78] intentionally omitted <==**
**----- Start of picture text -----**<br>
Brown (1) +U B UB 10__30VDC<br>I A 200mAmax.<br>100 kOhm R L<br>(4)<br>Port Black A<br>Load<br>39 V 39 V<br>39 V (3)<br>Blue<br>0V<br>**----- End of picture text -----**<br>
## **Applications**
Parts Counting
Object Detection
Tachometer input/gear-tooth profile
**www.redingtoncounters.com**
**101**
**Glossary**
|**TERM**<br>**DEFINITION**<br>A-B Input<br>The B input pulses are subtracted from the A<br>input pulses.<br>This type of input is used on counters &<br>indicators.<br>A+B Input<br>The A and B input pulses are added together.<br>This type input is used on counters and<br>position indicators.<br>AC<br>Alternating current; an electric current that<br>reverses its direction at recurring intervals.<br>Accuracy<br>The closeness of an indication or reading of a<br>measurement device to the actual value of the<br>quantity being measured. Usually expressed<br>as a ± percent of full scale output or reading,<br>Add/Subtract<br>The ability to count up and down.<br>Ammeter<br>An instrument used to measure current.<br>Analog<br>A signal that varies continuously in amplitude<br>without interruption.<br>Analog Output<br>A circuit whose output is a reproduction of its<br>input..<br>Automatic Reset A reset that is based on a pre-programmed<br>event. Used in counters or timers.<br>Baud Rate<br>The rate at which each bit is transferred to and<br>from a device.<br>Bidirectional<br>The counter or encoder can count in both<br>directions.<br>Bit<br>This is the name for a binary digit.<br>Byte<br>A sequence of adjacent binary digits operated<br>on as a single unit. A byte is eight bits in<br>length.<br>Capacitor<br>An assembly of one or more pairs of conduc-<br>tors separated by insulators used to store an<br>electrical charge. The capacitance of is<br>measured in FARADS or parts thereof.<br>CE<br>(Conformite Europeeene mark) A symbol (CE)<br>applied to finished products and machinery<br>indicating it meets all applicable European|Directives. For electrical and electronic<br>“finished products”, such as electronic and<br>electromechanical counters, hour meters,<br>these include the Low Voltage Directive and,<br>where relevant, the Electromagnetic Compat-<br>ibility (EMC) Directive.<br>Color code<br>The ANSI established color code for the<br>thermocouple wires in the negative lead is<br>always RED. Color code for base metal<br>thermocouples is YELLOW for Type K, BLACK<br>for type J, PURPLE for Type E and BLUE for<br>Type T.<br>Control point<br>The set point at which a system is to be<br>maintained.<br>CSA<br>(Canadian Standards Association) An inde-<br>pendent Canadian testing and standards-<br>making org. similar to Underwriters Laborato-<br>ries (UL) in the USA. “CSA -certified “ products<br>meet relevant CSA electrical and safety<br>standards.<br>Current sinking /Open collector<br>In the “off” state the transistor can be viewed as<br>an open switch. When energized it turns “ON”,<br>connecting the output to the ground return lead.<br>The transistor is usually NPN.<br>Current sourcing/Open collector<br>In the “off” state the transistor can be viewed as<br>an open switch. When energized it turns “ON”,<br>connecting the output to the voltage supply<br>lead. The transistor is usually PNP.<br>DC<br>Direct current: An electric current flowing in one<br>direction only and substantially constant in<br>value.<br>Die<br>A single piece of silicon onto which a semicon-<br>ductor circuit has been fabricated.<br>(Plural= Dice)<br>Digit<br>A measurement of the display span of a panel<br>meter. By convention, a full digit can assume<br>any value from 0 through 9, a 1/2 digit will<br>display a 1 and overload at 2. For example, the<br>full scale value of a 3 1/2 digit display is 1999.<br>Digital Volt Meter A device used to measure voltages and give a<br>digital read out.|
|---|---|
**www.redingtoncounters.com**
**102**
**Glossary**
||**Glossary**|
|---|---|
|DIN<br>A**D**eutsche**I**ndustrial**N**orme standard. Some<br>RCI products utilize these dimensional<br>standards.<br>Direct drive<br>Refers to the gear ratio in a mechanical<br>counter one revolution of the input shaft<br>equals 10 counts.<br>Drift<br>A change of a reading or a set point value over<br>long periods due to several factors including<br>change in ambient temperature, time, and line<br>voltage.<br>EMF<br>Electromotive force. A rise in (electrical)<br>potential energy. The principle unit is the volt.<br>EMI<br>Electromagnetic interference.<br>Encoder<br>An electromechanical device that translates<br>mechanical motion into electrical pulses.<br>FRAM<br>Nonvolatile memory. Uses the ferroelectric<br>effect for a storage mechanism.<br>Hertz<br>(Hz) Units in which the frequency is expressed.<br>Synonymous with cycles per second.<br>Hysteresis<br>In an ON-OFF controller it defines the differ-<br>ence between the two switching points. It<br>refers to the difference between the value at<br>which the alarm switches on and the value at<br>which the alarm switches off again.<br>Incremental encoder<br>A device that provides a series of periodic<br>signals due to mechanical motion. The number<br>of successive cycles corresponds to the<br>resolvable mechanical increments of motion.<br>Impedance<br>The total opposition to electrical flow (resistive<br>plus reactive).<br>Input impedance The resistance of a panel meter as seen from<br>the source. In the case of a voltmeter, this<br>resistance has to be taken into account when<br>the source impedance is high; in the case of<br>an ammeter, when the impedance is low.<br>Joule<br>The basic unit of thermal energy.<br>LCD<br>(Liquid Crystal Display) A liquid crystal display<br>is made of two glass plates, each with a<br>transparent conductive coating, which|sandwich the crystal material. When a voltage<br>is applied molecules in the liquid crystal align<br>themselves with the field generated preventing<br>light from passing, creating a display segment.<br>The pattern on the display forms the required<br>picture or numeral.<br>LED<br>(Light Emitting Diode) A diode which emits light<br>of a particular wavelength when a current is<br>passed through it.<br>LSI<br>( Large Scale Integration) Used to refer to<br>integrated circuits which today have from<br>thousands to millions of components on one<br>silicon chip.<br>Load<br>The electrical demand of a process expressed<br>as power (watts), current (amps), or resistance<br>(ohms).<br>Maximum operating temperature<br>The maximum temperature at which an<br>instrument can be operated and still be within<br>operating specifications.<br>Micro<br>A prefix meaning one millionth.<br>Milli<br>A prefix meaning one thousandth.<br>Multiplication<br>Any technique used to obtain an output<br>resolution different from the line count.<br>Nano<br>A prefix meaning one thousand-millionth.<br>Noise<br>An unwanted electrical interference on the<br>signal wires.<br>OHM<br>The unit of electrical resistance. A constant<br>voltage of one volt across a resistance of one<br>OHM will produce a current in it of one<br>ampere. OHMS LAW V=IR<br>Ohmmeter<br>An instrument used to measure resistance.<br>Optical Isolator<br>Sometimes referred to as an optocoupler. A<br>device that isolates two stages of a circuit;<br>e.g.., input and output from each other so that<br>interference in one will not effect the other.<br>Optical Isolation A method of reducing noise interference<br>between two circuits using optical isolators.<br>Predetermining<br>The counter can provide an “output” signal at a<br>predetermined count or time.|
**www.redingtoncounters.com**
**103**
**Glossary**
Prescaler Used to convert a pulse input signal to the desired units of indication. Quadrature Signals A dual output encoder used for bidirectional motion control. One channel leads the other by 90 degrees. RAM ( Random Access Memory) A memory device which may be accessed at random and which may be written to (altered) or read at any time. Range The values specified by upper and lower limits. Rate Velocity or distance/unit time; can be rotational distance. Relays/Electromechanical Relays offer one or more “hard” contacts (metal-to metal) and are switched to the open or closed position by applying voltage to an electromagnetic coil. Resistance The resistance to the flow of electric current measured in ohms. For a conductor, a resistance is a function of diameter, resistivity (an intrinsic) property of the material and length. Resistor A device used primarily for its resistance, which is measured in OHMS. Its primary use is to limit the flow of electrons through a circuit. Resolution The number of increments on an encoder disc. Also, the smallest possible value that an instrument can measure. Revolution drive Refers to the gear ratio in a mechanical counter. One revolution of the input shaft equals 1 count. ROM (Ready Only Memory) A device is programmed with information which should not be lost and which only needs to be read by a computer. Once programmed it cannot be reprogrammed. RS 485/422/232 Standards established by the EIA for serial data transmission between two devices.
||**Glossary**|
|---|---|
|RTD|Resistance temperature detector. The resis-|
||tance changes as a function of temperature.|
|Scaling|For direct readout in engineering units, scaling|
||is the capability of the product to associate any|
||desired value to the electrical input range.|
|Seebeck effect|This is the basis of thermocouples. When a|
||circuit is formed by a junction of two dissimilar|
||metals and the junctions are held at different|
||temperatures, a current will flow in the circuit|
||caused by the difference in temperature|
||between the two junctions.|
|Silicon|The basic element used in the manufacturer of|
||most semiconductor devices.|
|Solid-State Relays||
||Use switching elements such as transistors for|
||DC loads and SCR’s or FET’s for AC loads.|
|Stroke Counter|Refers to the input shaft of a mechanical|
||counter. The counter will count when the lever|
||is moved through an arc.|
|Thermocouple|The junction of two dissimilar metals which has|
||a voltage output proportional to the difference|
||in temperature between the hot junction and|
||the wires ( cold junction).|
|Thermocouple type|Thermocouple type<br>Type<br>Material (ANSI Symbol)|
||J<br>Iron/Constantan|
||K<br>Chromel/Alumel|
||T<br>Copper/Constantan|
||E<br>Chromel/Constantan|
||R<br>Platinum/Platinum|
||13% Rhodium|
||S<br>Platinum/Platinum|
||10% Rhodium|
||B<br>Platinum|
||6% Rhodium/Platinum|
||/30% Rhodium|
||G*<br>Tungsten Tungsten|
||26% Rhenium|
||C*<br>Tungsten|
||5% Rhenium/Tungsten|
||26% Rhenium|
||D*<br>Tungsten|
||3% Rhenium/Tungsten|
||/25% Rhenium|
*Not ANSI symbols
**www.redingtoncounters.com**
**104**
**Glossary**
||**Glossary**|
|---|---|
|Top coming<br>The input shaft rotates towards you, when<br>viewing the counter from the front.<br>Top going<br>The input shaft rotates away from you, when<br>viewing the counter from the front.<br>Totalizer<br>A type of counter with no outputs, which is used<br>for accumulating the number of input pulses.<br>Transistor<br>From “transfer resistor”, it is a semiconductor<br>device with threeelectrodes that act as either<br>an amplifier or switch.<br>Transducer<br>A device (or medium) that converts energy from<br>one form to another. The term is generally<br>applied to devices that take physical phenom-<br>ena (pressure, temperature, humidity, flow,<br>etc.) and convert them to electrical signal.<br>Sometimes referred to as “sensor”.<br>UL<br>Underwriters Laboratories, Inc. An independent<br>laboratory that establishes safety standards for<br>commercial and industrial products.<br>Unidirectional<br>The counter or encoder can only count in one<br>direction.<br>Volt<br>The (electrical) potential difference between<br>two points in a circuit. The fundamental unit is<br>derived as work per unit charge- (V=W/Q). One<br>volt is the potential difference required to move<br>one coulomb of charge between two points in<br>a circuit using one joule of energy.<br>X2,X4 Logic<br>A type of logic that multiplies the signal by a<br>factor of 2 or 4 respectively.<br>**NEMA STANDARDS**<br>**NEMA Standards Publication No. 250 guidelines**<br>NEMA 1<br>Indoor use- Protects against accidental contact<br>by personnel & falling dirt.<br>NEMA 2<br>Indoor use-Protects against falling dirt, liquid, &<br>light splash.<br>NEMA 3<br>Outdoor use-Protects against rain, sleet, snow,<br>dirt & dust.<br>NEMA 3S<br>Outdoor use- Protects against rain, sleet, snow,<br>dirt, dust & ice buildup.<br>NEMA 4<br>In-or-Outdoor-Protects against dirt, dust, hose<br>down, (and heavy splash).|NEMA 4X<br>In-or Outdoor- Protects against dirt, dust, hose<br>down & corrosion.<br>NEMA 6<br>In-or Outdoor- Protects against dirt, dust, hose<br>down & occasional submersion.<br>NEMA 6P<br>In-or Outdoor- Protects against dirt, dust, hose<br>down & prolonged submersion.<br>NEMA 7<br>Indoor Use- For use in areas of explosive<br>gases or vapors or combustible dust.<br>NEMA 9<br>Indoor Use- For use in areas of atmospheres<br>containing combustible dust.<br>NEMA 12<br>Indoor Use- Protects against dirt, dust, light<br>splash & oil or coolant spray.<br>NEMA 13<br>Indoor Use- Protects against dirt, dust, light<br>splash, & oil or coolant spray.<br>**The rating system established by IEC Publications 144 and**<br>**529 define the following “IP” ratings:**<br>**1ST CHARACTERISTIC:**<br>Protection against and penetration of solid bodies.<br>**Numeral**<br>**Short Description**<br>0<br>Non-protected<br>1<br>Protected against solid objects greater<br>than 50mm<br>2<br>Protected against solid objects greater<br>than 12mm<br>3<br>Protected against solid objects greater<br>than 2.5mm<br>4<br>Protected against solid objects greater<br>than 1.0mm<br>5<br>Dust protected<br>6<br>Dust-tight<br>**2nd CHARACTERISTIC:**<br>Protection against and penetration of liquids.<br>**Numeral**<br>**Short Description**<br>0<br>Non-protected<br>1<br>Protected against dripping water<br>2<br>Protected against dripping water when tilted up<br>to 15 degrees<br>3<br>Protected against spraying water<br>4<br>Protected against splashing water<br>5<br>Protected against water jets<br>6<br>Protected against heavy seas<br>7<br>Protected against the effects of immersion<br>8<br>Protected against submersion|
**www.redingtoncounters.com**
**105**
**Part# Index**
||**1**||||**2**|||42-1904||34|5330-2200||76|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|||||||||43-1904||34|5330-2201||76|
|1-1006||19|||2-1006|19||44-1904||34|5400-0010||15|
|1-2015||35|||2-1007|20||45-1904||34|5400-1010||15|
|1-2025||35|||2-1016|19|||||55XX||54|
|1-2035||35|||2-1017|20|||**5**||5600||57|
|1-2045||35|||2-1284|28|||||5601||57|
|1-2215||36|||2-2936|39||5-2835||38|5602||57|
|1-2225||36|||2-4016|21||5-4645||42|5610||57|
|1-2235||36|||2-4017|21||5003-001S||13, 50, 76|5611||57|
|1-2245||36|||2-4103|41||5003-002S||8, 46|5612||57|
|1-2315||36|||2-4104|41||5003-003S||8, 46|5620||57|
|1-2325||36|||2-4416|23||5003-004S||8, 46|5621||57|
|1-2715||37|||2-4615|42||5003-005S||8, 46|5622||57|
|1-2735||37|||2-4625|42||5003-007S||72, 74|5630||57|
|1-2916||39|||2-4635|42||5120-0000||48|5631||57|
|1-2926||39|||2-4645|42||5120-0100||48|5632||57|
|1-2936||39|||200507-046S|98||5120-0200||48|5640||57|
|1-2946||39|||200557-001S|85,|88|5120-0310||48|5641||57|
|1-4103||41|||200557-002S|85,|88|5120-1000||48|5642||57|
|1-4615||42|||21-1904|34||5120-1100||48|5650||57|
|1-4625||42|||21-2916|40||5120-1200||48|5651||57|
|1-4635||42|||21-2926|40||5120-2000||48|5652||57|
|1-4635T||42|||21-2936|40||5120-2100||48|5660||57|
|1-4645||42|||21-2946|40||5120-2200||48|5661||57|
|1-PCU-13||44|||22-1904|34||5140-0000||48|5662||57|
|1-PCU-14||44|||22-2936|40||5140-0100||48|5670||57|
|1-PCU-24||44|||23-1904|34||5140-0200||48|5671||57|
|1-PCU-33||44|||24-1904|34||5140-0311||48|5672||57|
|1-PCU-33T||44|||25-1904|34||5140-0312||48|5700||60|
|1-PCU-34||44||||||5200-0000||11|5701||60|
|1-PCU-43||44|||**3**|||5201-0000||11|5702||60|
|1-PCU-44||44||||||5202-0000||11|5703||60|
|10007-009S||42|||3-1006|19||5210-0000||11|5704||60|
|10007-010S||35|||3-1007|20||5211-0000||11|5705||60|
|10011-001S||42|||3-1804-10|33||5300-0000||13|5706||60|
|1022-006S||37,|38,|39|3-1804-2|33||5300-0001||13|5707||60|
|1071-024S||19|||3-1804-3|33||5300-0100||13|5708||60|
|11-0825||30|||3-1804-4|33||5300-0101||13|5709||60|
|11-0845||30|||3-1804-5|33||5300-1000||13|5710||60|
|11-1904||34|||3-1804-6|33||5300-1001||13|5711||60|
|11-2916||40|||3-1804-7|33||5300-1010||13|5712||60|
|11-2936||40|||3-1804-8|33||5300-1011||13|5713||60|
|11B-1415||31|||3-1804-9|33||5300-1100||13|5902||62|
|11B-1425||31|||3-2835|38||5300-2000||13|5912||62|
|11B-1435||31|||3-4104|41||5300-2001||13|5922||62|
|11B-1445||31|||31-1904|34||5300-2100||13|5932||62|
|11B-1515||31|||32-1904|34||5300-2200||13|5942||62|
|11B-1525||31|||33-1904|34||5300-2201||13|5952||62|
|11B-1535||31|||3301-0000|8||5320-0000||50|5962||62|
|11B-1545||31|||3301-0010|8||5320-0001||50|5972||62|
|11B-1615||31|||3301-1000|8||5320-0100||50|5982||62|
|11B-1625||31|||3301-1010|8||5320-0101||50|5992||62|
|11B-1635||31|||3301-2000|8||5320-1000||50||||
|11B-1645||31|||3301-2010|8||5320-1001||50||**6**||
|11B-1715||31|||3301-3000|8||5320-1010||50||||
|11B-1725||31|||3301-3010|8||5320-1011||50|6510-0060||100|
|11B-1735||31|||3302-4322|10||5320-1100||50|6510-0100||100|
|11B-1745||31|||3311-0000|46||5320-2000||50|6510-0600||100|
|12-1804||33|||3311-0010|46||5320-2001||50|6510-1000||100|
|12-1904||34|||3311-1000|46||5320-2100||50|6510-1200||100|
|1255-004S||39|||3311-1010|46||5320-2200||50|6520-0010||100|
|13-1804||33|||3311-2000|46||5320-2201||50|6520-0012||100|
|13-1904||34|||3311-2010|46||5321-0000||50|6520-0100||100|
|14-1904||34|||3311-3000|46||5321-0001||50|6520-0120||100|
|15-1904||34|||3311-3010|46||5322-0000||50|6520-0500||100|
|1726-044S||93,|97||34-1904|34||5322-0001||50|6520-0600||100|
|1726-045S||93,|97||35-1904|34||5330-0000||76||||
|1726-046S||93,|97|||||5330-0001||76|**7**|||
|1887-021S||98|||**4**|||5330-1000||76||||
|1895-004S||98||||||5330-1001||76|7-2215||36|
|1895-005S||98|||4-2835|38||5330-2000||76|7-2225||36|
|1895-006S||98|||41-1904|34||5330-2001||76|7-2235||36|
**www.redingtoncounters.com**
**106**
**Part# Index**
|7-2245|36|||732-0001||74|85KSNP|83||P2-1006|19|
|---|---|---|---|---|---|---|---|---|---|---|---|
|710-0001|66|||732-0002||74|85KSP1|83||P2-1007|20|
|710-0002|66|||732-0003||74|85KSP2|83||P2-1016|19|
|710-0003|66|||732-0004||74|85KSP3|83||P2-1027|20|
|710-0006|66|||750-0002||43|85KSP4|83||P2-1284|28|
|710-0008|66|||750-0007||43|85KSP5|83||P2-3106|29|
|710-0009|66|||750-0016||43|85KSPT|83||P2-4816|24|
|710-0013|66|||750-0114||43|85KSR1|83||P2-4817|24|
|710-0014|66|||750-0156||43|85KSR2|83||P2-4904|26|
|710-0018|66||||||85KSRD|83||P2-4906|26|
|710-0024|66||||**8**||85KSRT|83||P2-7717/60|65|
|710-0026|66||||||85KSTK|83||P3-1006|19|
|710-0032|66|||8-1006||19|85KSVA|83||P31-1026|19|
|710-0051|66|||8-1007||20|85KSVD|83||P32-1026|19|
|711-0013|67|||8-4416||23|85XX|84||P33-1026|19|
|711-0014|67|||8301||93|8800-0000|88||P38-1026|19|
|711-0015|67|||8301-0110||93|8800-0001|88||P8-1006|19|
|711-0019|70|||8301-1110||93|8800-0010|88||P8-1027|20|
|711-0020|70|||8302||93|8800-0011|88||P8-3206|29|
|711-0041|70|||8302-0010||93|8800-0100|88||P8-4816|24|
|711-0113|67|||8302-0011||93|8800-0101|88||P8-4817|24|
|711-0114|67|||8302-0100||93|8800-0110|88||P8-4904|26|
|711-0120|67|||8302-0101||93|8800-0111|88||P8-4906|26|
|711-0123|67|||8302-1010||93|8810-0000|88||P9-3206|29|
|711-0124|67|||8302-1011||93|8810-0001|88||P9-4904|26|
|711-0130|67|||8302-1100||93|8810-0010|88||P9-4906|26|
|711-0131|67|||8302-1101||93|8810-0011|88||PR2-1284|28|
|711-0132|67|||8303||93|8810-0100|88||||
|711-0133|67|||8303-0100||93|8810-0101|88||**R**||
|711-0134|67|||8303-0101||93|8810-0110|88||||
|711-0138<br>711-0150|67<br>69|||8303-0110<br>8303-0111||93<br>93|8810-0111|88||R2-1007<br>R2-1017|20<br>20|
|711-0152<br>711-0160|69<br>69|||8303-1100<br>8303-1101||93<br>93|**9**|||R2-3106<br>R2-4016|29<br>21|
|711-0161<br>711-0162|69<br>69|||8303-1110<br>8303-1111||93<br>93|9200-HT<br>9200-HTK|98<br>98||R2-4017<br>R2-4416|21<br>23|
|711-0163<br>711-0164|69<br>69|||8304<br>8304-0100||93<br>93|9415-001<br>9415-003|16<br>16||R2-4816<br>R2-7717/60|24<br>65|
|711-0170<br>711-0171|69<br>69|||8304-0101<br>8304-1100||93<br>93|9415-005<br>9425-001|16<br>63||R8-3206<br>R8-4416|29<br>23|
|711-0180<br>711-0182|69<br>69|||8304-1101<br>8321||93<br>97|9425-003<br>9425-005|63<br>63||R8-4817<br>R9-4016|24<br>21|
|711-0190<br>711-0191|69<br>69|||8321-0110<br>8321-1110||97<br>97|98WF|30,|40|R9-4017<br>RKC 8T2/S618|21<br> 100|
|711-0192<br>711-0193<br>711-0194<br>711-0195|69<br>69<br>69<br>69|||8322<br>8322-0010<br>8322-0011<br>8322-0100||97<br>97<br>97<br>97|**B**<br>B2-4904<br>B2-4906|26<br>26||RV2-4416<br>RV8-4416<br>**S**|23<br>23|
|711-0215<br>711-0216<br>711-0217<br>720-0001|67<br>67<br>67<br>71|||8322-0101<br>8322-1010<br>8322-1011<br>8322-1100||97<br>97<br>97<br>97|B2-5804<br>B2-5804/E2<br>B2-5806<br>B2-5806/E2|45<br>45<br>45<br>45||SR2-4016<br>SR2-4017<br>SR2-4816<br>SR2-7717/60|21<br>21<br>24<br>65|
|720-0003|71|||8322-1101||97|B8-4904|26||SR8-4816|24|
|720-0004|71|||85KLAD||83|B8-4906|26||SR8-4817|24|
|720-0007|71|||85KLCA||83|B8-5804|45||||
|720-0008|71|||85KLCD||83|B8-5804/E8|45||**T**||
|720-0011<br>720-0012<br>720-0030|71<br>71<br>71|||85KLFQ<br>85KLIR<br>85KLJT||83<br>83<br>83|B8-5806<br>B8-5806/E2|45<br>45||T2-4016<br>T2-4017|21<br>21|
|720-0031<br>720-0036|71<br>71|||85KLKT<br>85KLPT||83<br>83|**D**|||**V**||
|720-5300<br>721-0003<br>721-0004<br>721-0017<br>721-0018<br>722-0001<br>722-0002<br>722-0003<br>722-0004<br>731-0006<br>731-0040<br>731-0041<br>731-0042<br>731-0046|64<br>66<br>64, <br>66<br>66<br>72<br>72<br>72<br>72<br>67<br>67<br>67<br>67<br>69|66,|71|85KLRT<br>85KLTK<br>85KLVA<br>85KLVD<br>85KSAD<br>85KSAN<br>85KSCA<br>85KSCD<br>85KSDC<br>85KSFQ<br>85KSHG<br>85KSHR<br>85KSIR<br>85KSJT||83<br>83<br>83<br>83<br>83<br>83<br>83<br>83<br>83<br>83<br>83<br>83<br>83<br>83|D2-1284<br>D2-4904<br>D2-4906<br>D8-4817<br>DW-AD-601M8 <br>**E**<br>E1-1804<br>E2-1804<br>E3-1804<br>**P**|28<br>26<br>26<br>24<br> 101<br>17<br>18<br>18||V1-2936<br>V1-4816<br>V2-4416<br>V2-4816<br>V2-4817<br>V3-4816<br>V8-4016<br>V8-4017<br>V8-4416<br>V8-4816<br>V8-4817<br>V9-4816|39<br>24<br>23<br>24<br>24<br>24<br>21<br>21<br>23<br>24<br>24<br>24|
|731-0051|67|||85KSKT||83|P1-1006|19||||
**www.redingtoncounters.com**
**107**
**Custom Products and Services**
## **Custom Capabilities**
Redington manufactures a variety of custom products for our customers. These products range from unique items designed for specific applications, to slight variations on our existing models.
If you don’t see exactly what you are looking for, give us a call and one of our sales representative can work with you to solve your requirements.
## **Contract Electronics, Molding and Assembly**
Whether you need electronic design and production, plastic injection molding or product assembly, Redington offers a wide variety of custom capabilities to meet your requirements. With over 43 years experience as a high quality manufacturer, we can help you get your product to market quickly, while maintaining the highest levels of quality.
Contact us today to learn more about how we can help you with your specific needs.
**www.redingtoncounters.com**
**108**
Updated at April 22, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →