AC/DC Power Supply, 1 Output, 90.24 W, 48 VDC, 1.88 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC External Plug In Adaptor Power Supplies
- No. of Outputs:1 Output; Output Power Max:90.24W; Output Voltage - Output 1:48V; Output Current - Output 1:1.88A; Output Voltage - Output 2:-; Output Current - Output 2:-; Output Connec
- SVHC: No SVHC (25-Jun-2025)
- Plug Type: EU
- Product Range: OWA-90E Series
- No. of Outputs: 1 Output
- Output Connector: 4 Way XLR
- Output Power Max: 90.24W
- Input Voltage VAC: 90V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 1.88A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 48VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Power Supply Applications: -
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 29.38 € |
| Current stock | 10+ |
| Lead time | 30 days |
**OWA - 90E series** 90W Single Output Waterproof Switching Adaptor ## **IP67** ## ■ **Features** - ‧Universal AC input / Full range (up to 264VAC) - ‧Built-in active PFC function - ‧High efficiency up to 91% - ‧Protections: Short circuit / Over current / - Over voltage / Over temperature ## ■ **Applications** - ‧Robotic lawn mower - ‧Household appliance - ‧Battery charging - ‧General electronic products in dusty or humid environment - ‧Class Ⅱ power unit, no FG - ‧Fanless design, cooling by free air convection - ‧No load power consumption <0.15W - ‧ErP step 2 - ‧5 years warranty ## ■ **Description** OWA-90E is a 90W AC/DC, class Ⅱ (without earth pin) external power supply series pinpointing the waterproof feature. The fully-potted silicone inside the plastic enclosure enhances the heat dissipation; it also benefits that the OWA-90E achieves **I** P67 level so that this series specializes the application in which the damp, humidity or dust resistance is needed for the external power supply. The no load power consumption is less than 0.15W, following the major demand for adaptors concerning the energy efficiency in Europe. Moreover, OWA-90E fits the applications requiring EN60335 such as household appliances, greatly simplifying the system design. OWA-90E adopts the universal input range from 90VAC to 264VAC and incorporates a built-in PFC function. With the working efficiency up to 91%, OWA-90E is cooled by free air convection; the working temperature ranges from -40℃ to +70℃. ## ■ **Model Encoding** **OWA - 90E -** [| **12** Output voltage Europe type of plug Output wattage Series name _File Name:OWA-90E-SPEC 2014-01-20_ **OWA - 90E series** 90W Single Output Waterproof Switching Adaptor ## **SPECIFICATION** ||**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**RATED POWER**<br>**OUTPUT**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIMENote.4**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (**<br>**.)**<br>**Typ**<br>**LEAKAGE CURRENT**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVER CURRENT**<br>**OVER VOLTAGE**<br>**OVER TEMPERATURE**<br>500ms, 80ms<br>/ 230VAC<br>at 95% load 115VAC<br>16ms at full load 115VAC / 230VAC<br>90 ~ 264VAC 127 ~ 373VDC<br>47 ~ 63Hz<br>PF>0.98/115VAC, PF>0.96/230VAC at full load<br>0.95A / 115VAC 0.5A / 230VAC<br><0.25mA / 240VAC<br>95 ~ 108%<br>Protection type : Constant current limiting, recovers automatically after fault condition is removed<br>-40 ~ +70℃(Refer to "Derating Curve")<br>20 ~ 95% RH non-condensing<br>-40 ~ +80<br>, 10 ~ 95% RH<br>℃<br>±0.03%/℃(0 ~ 50℃)<br>10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes<br>292.8K hrs min. MIL-HDBK-217F (25℃)<br>Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN55014-2, light industry level (surge L- N : 2KV), criteria A<br>171*63*37.5mm<br>1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃of ambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel<br>capacitor.<br>3. Tolerance : includes set up tolerance, line regulation and load regulation.<br>4. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.<br>0.92Kg; 16pcs/15.7Kg/1.01CUFT<br>**RIPPLE & NOISE (max.)Note.2**<br>**VOLTAGE TOLERANCENote.3**<br>**ENVIRONMENT**<br>**PROTECTION**<br>Shut down o/p voltage, re-power on to recover<br>**SHORT CIRCUIT**<br>Hiccup mode, recovers automatically after fault condition is removed<br>Protection type :Shut down o/p voltage, re-power on to recover<br>COLD START 50A(twidth=550 s measured at 50% Ipeak) at 230VAC<br>15 ~ 17V<br>17.5 ~ 21V<br>23 ~ 27V<br>28 ~ 34V<br>34 ~ 40V<br>41 ~ 46V<br>46 ~ 54V<br>54 ~ 60V<br>59 ~ 66V<br>89%<br>90%<br>90%<br>90%<br>90%<br>91%<br>91%<br>91%<br>91%<br>±4.0%<br>±4.0%<br>±4.0%<br>±3.0%<br>±3.0%<br>±2.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±1.5%<br>±1.0%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>12V<br>15V<br>20V<br>24V<br>30V<br>36V<br>42V<br>48V<br>54V<br>**OWA-90E-12 OWA-90E-15 OWA-90E-20 OWA-90E-24 OWA-90E-30 OWA-90E-36 OWA-90E-42 OWA-90E-48 OWA-90E-54**<br>150mVp-p<br>150mVp-p<br>150mVp-p<br>150mVp-p<br>200mVp-p<br>200mVp-p<br>250mVp-p<br>250mVp-p<br>350mVp-p<br>7.5A<br>6A<br>4.5A<br>3.75A<br>3A<br>2.5A<br>2.15A<br>1.88A<br>1.67A<br>90W<br>90W<br>90W<br>90W<br>90W<br>90W<br>90.3W<br>90.24W<br>90.18W<br>**SAFETY &**<br>**EMC**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**SAFETY STANDARDS**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>EN61558-1,-2-16 listed, EN60335-1 listed, IP67 approved<br>I/P-O/P:3.75KVAC<br>I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH<br>Compliance to EN55022 (CISPR22) Class B, EN55014-1 Class B, EN61000-3-2,-3<br>μ|**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**RATED POWER**<br>**OUTPUT**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIMENote.4**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (**<br>**.)**<br>**Typ**<br>**LEAKAGE CURRENT**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVER CURRENT**<br>**OVER VOLTAGE**<br>**OVER TEMPERATURE**<br>500ms, 80ms<br>/ 230VAC<br>at 95% load 115VAC<br>16ms at full load 115VAC / 230VAC<br>90 ~ 264VAC 127 ~ 373VDC<br>47 ~ 63Hz<br>PF>0.98/115VAC, PF>0.96/230VAC at full load<br>0.95A / 115VAC 0.5A / 230VAC<br><0.25mA / 240VAC<br>95 ~ 108%<br>Protection type : Constant current limiting, recovers automatically after fault condition is removed<br>-40 ~ +70℃(Refer to "Derating Curve")<br>20 ~ 95% RH non-condensing<br>-40 ~ +80<br>, 10 ~ 95% RH<br>℃<br>±0.03%/℃(0 ~ 50℃)<br>10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes<br>292.8K hrs min. MIL-HDBK-217F (25℃)<br>Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN55014-2, light industry level (surge L- N : 2KV), criteria A<br>171*63*37.5mm<br>1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃of ambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel<br>capacitor.<br>3. Tolerance : includes set up tolerance, line regulation and load regulation.<br>4. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.<br>0.92Kg; 16pcs/15.7Kg/1.01CUFT<br>**RIPPLE & NOISE (max.)Note.2**<br>**VOLTAGE TOLERANCENote.3**<br>**ENVIRONMENT**<br>**PROTECTION**<br>Shut down o/p voltage, re-power on to recover<br>**SHORT CIRCUIT**<br>Hiccup mode, recovers automatically after fault condition is removed<br>Protection type :Shut down o/p voltage, re-power on to recover<br>COLD START 50A(twidth=550 s measured at 50% Ipeak) at 230VAC<br>15 ~ 17V<br>17.5 ~ 21V<br>23 ~ 27V<br>28 ~ 34V<br>34 ~ 40V<br>41 ~ 46V<br>46 ~ 54V<br>54 ~ 60V<br>59 ~ 66V<br>89%<br>90%<br>90%<br>90%<br>90%<br>91%<br>91%<br>91%<br>91%<br>±4.0%<br>±4.0%<br>±4.0%<br>±3.0%<br>±3.0%<br>±2.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±1.5%<br>±1.0%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>12V<br>15V<br>20V<br>24V<br>30V<br>36V<br>42V<br>48V<br>54V<br>**OWA-90E-12 OWA-90E-15 OWA-90E-20 OWA-90E-24 OWA-90E-30 OWA-90E-36 OWA-90E-42 OWA-90E-48 OWA-90E-54**<br>150mVp-p<br>150mVp-p<br>150mVp-p<br>150mVp-p<br>200mVp-p<br>200mVp-p<br>250mVp-p<br>250mVp-p<br>350mVp-p<br>7.5A<br>6A<br>4.5A<br>3.75A<br>3A<br>2.5A<br>2.15A<br>1.88A<br>1.67A<br>90W<br>90W<br>90W<br>90W<br>90W<br>90W<br>90.3W<br>90.24W<br>90.18W<br>**SAFETY &**<br>**EMC**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**SAFETY STANDARDS**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>EN61558-1,-2-16 listed, EN60335-1 listed, IP67 approved<br>I/P-O/P:3.75KVAC<br>I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH<br>Compliance to EN55022 (CISPR22) Class B, EN55014-1 Class B, EN61000-3-2,-3<br>μ|**OWA-90E-12 **|**OWA-90E-15 **|**OWA-90E-20 **|**OWA-90E-24 **|**OWA-90E-30 **|**OWA-90E-36 **|**OWA-90E-42 **|**OWA-90E-48 **|**OWA-90E-54**| |---|---|---|---|---|---|---|---|---|---|---|---| |||**DC VOLTAGE**|12V|15V|20V|24V|30V|36V|42V|48V|54V| |||**RATED CURRENT**|7.5A|6A|4.5A|3.75A|3A|2.5A|2.15A|1.88A|1.67A| |||**RATED POWER**|90W|90W|90W|90W|90W|90W|90.3W|90.24W|90.18W| |||**RIPPLE & NOISE (max.)Note.2**|150mVp-p|150mVp-p|150mVp-p|150mVp-p|200mVp-p|200mVp-p|250mVp-p|250mVp-p|350mVp-p| |||**VOLTAGE TOLERANCENote.3**|±4.0%|±4.0%|±4.0%|±3.0%|±3.0%|±2.0%|±1.0%|±1.0%|±1.0%| |||**LINE REGULATION**|±0.5%|±0.5%|±0.5%|±0.5%|±0.5%|±0.5%|±0.5%|±0.5%|±0.5%| |||**LOAD REGULATION**|±1.5%|±1.0%|±0.5%|±0.5%|±0.5%|±0.5%|±0.5%|±0.5%|±0.5%| |||**SETUP, RISE TIMENote.4**|500ms, 80ms<br>/ 230VAC<br>at 95% load 115VAC||||||||| |||**HOLD UP TIME (Typ.)**|16ms at full load 115VAC / 230VAC||||||||| |||**VOLTAGE RANGE**|90 ~ 264VAC 127 ~ 373VDC||||||||| |||**FREQUENCY RANGE**|47 ~ 63Hz||||||||| |||**POWER FACTOR (Typ.)**|PF>0.98/115VAC, PF>0.96/230VAC at full load||||||||| |||**EFFICIENCY (Typ.)**|89%|90%|90%|90%|90%|91%|91%|91%|91%| |||**AC CURRENT (Typ.)**|0.95A / 115VAC 0.5A / 230VAC||||||||| |||**INRUSH CURRENT (**<br>**.)**<br>**Typ**|COLD START 50A(twidth=550 s measured at 50% Ipeak) at 230VAC<br>μ||||||||| |||**LEAKAGE CURRENT**|<0.25mA / 240VAC||||||||| |||**OVER CURRENT**|95 ~ 108%<br>Protection type : Constant current limiting, recovers automatically after fault condition is removed||||||||| |||**SHORT CIRCUIT**|Hiccup mode, recovers automatically after fault condition is removed||||||||| |||**OVER VOLTAGE**|Protection type :Shut down o/p voltage, re-power on to recover<br>15 ~ 17V<br>17.5 ~ 21V<br>23 ~ 27V<br>28 ~ 34V<br>34 ~ 40V<br>41 ~ 46V<br>46 ~ 54V<br>54 ~ 60V<br>59 ~ 66V||||||||| |||**OVER TEMPERATURE**|Shut down o/p voltage, re-power on to recover||||||||| |||**WORKING TEMP.**|-40 ~ +70℃(Refer to "Derating Curve")||||||||| |||**WORKING HUMIDITY**|20 ~ 95% RH non-condensing||||||||| |||**STORAGE TEMP., HUMIDITY**|-40 ~ +80<br>, 10 ~ 95% RH<br>℃||||||||| |||**TEMP. COEFFICIENT**|±0.03%/℃(0 ~ 50℃)||||||||| |||**VIBRATION**|10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes||||||||| |||**SAFETY STANDARDS**|EN61558-1,-2-16 listed, EN60335-1 listed, IP67 approved||||||||| |||**WITHSTAND VOLTAGE**|I/P-O/P:3.75KVAC||||||||| |||**ISOLATION RESISTANCE**|I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH||||||||| |||**EMC EMISSION**|Compliance to EN55022 (CISPR22) Class B, EN55014-1 Class B, EN61000-3-2,-3||||||||| |||**EMC IMMUNITY**|Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN55014-2, light industry level (surge L- N : 2KV), criteria A||||||||| |||**MTBF**|292.8K hrs min. MIL-HDBK-217F (25℃)||||||||| |||**DIMENSION**|171*63*37.5mm||||||||| |||**PACKING**|0.92Kg; 16pcs/15.7Kg/1.01CUFT||||||||| |||1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃of ambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel<br>capacitor.<br>3. Tolerance : includes set up tolerance, line regulation and load regulation.<br>4. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.|||||||||| _File Name:OWA-90E-SPEC 2014-01-20_ **OWA - 90E series** ## 90W Single Output Waterproof Switching Adaptor **==> picture [511 x 668] intentionally omitted <==** **----- Start of picture text -----**<br> Block Diagram<br>PFC fosc : 50~120KHz<br>PWM fosc : 60~130KHz<br>EMI FILTER PFC POWER RECTIFIERS +V<br>I/P & CIRCUIT SWITCHING & -V<br>RECTIFIERS FILTER<br>O.L.P.<br>O.T.P. O.L.P. DETECTION<br>PWM & PFC CIRCUIT<br>CONTROL<br>O.V.P.<br>Derating Curve Static Characteristics<br>100<br>100<br>90<br>80<br>230VAC 80<br>Input only<br>60 70<br>50<br>60<br>40<br>50<br>20<br>40<br>-40 -25 -10 0 15 30 50 60 70 (HORIZONTAL) 90 100 125 135 145 155 165 175 180 200 230 264<br>AMBIENT TEMPERATURE ( ℃ ) INPUT VOLTAGE (V) 60Hz<br>LOAD (%) LOAD (%)<br>**----- End of picture text -----**<br> _File Name:OWA-90E-SPEC 2014-01-20_ ## 90W Single Output Waterproof Switching Adaptor ## **OWA - 90E series** **==> picture [511 x 668] intentionally omitted <==** **----- Start of picture text -----**<br> Mechanical Specification Unit:mm<br>171<br>5<br>5<br>1500±20<br>300±20<br>85.5 3 2<br>H05RN-F 1.0mm ×2 2C 4 1<br>H05RN-F 1.0mm 2 ×2C<br>5<br>5<br>※ T case: Max. Case Temperature.<br>Plug Assignment<br>All models : Jingcheng GCA012-4P, or<br>Neutrik NC4MX, or equivalent<br>3 2 PIN NO. OUTPUT<br>4 1 1,2 +V<br>3,4 -V<br>Recommend Mounting Direction<br>Installation Manual<br>Please refer to : http://www.meanwell.com/webnet/search/InstallationSearch.html<br>2-<br>ψ<br>4.5<br>63<br>31.5<br>37.5<br>**----- End of picture text -----**<br> _File Name:OWA-90E-SPEC 2014-01-20_
Updated at June 3, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →