OHB145J12
PISTOL HANDLE, DISCONNECT SWITCH, 145MM
- Manufacturer: ABB
- Product type: Industrial Switch Accessories
- SVHC: To Be Advised
- For Use With: ABB OT90A-315 Disconnect Switches
- Product Range: OH
- Accessory Type: Pistol Handle
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 42.58 € |
| Current stock | 10+ |
| Lead time | 9 days |
**==> picture [106 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> Protection and Connection Pronection ond Cann bho<br>**----- End of picture text -----**<br> Transfer, change-over and bypass switches Securing your power to perform securing your power to perform ## Videos ## Promotional video: With ABB transfer switches, you are never left in the dark ## Installation of accessories – How to? Motorized transfer switches OTM 40…125 A Motorized transfer switches OTM 160…800 A Motorized transfer switches OTM 1000…3200 A ## Additional information Manual change-over switches Ordering information for OT16...OT125_C **==> picture [307 x 381] intentionally omitted <==** **----- Start of picture text -----**<br> Open transition<br>1 Simple I-O-II –operation where the handle is<br>padlockable in O-position and door interlock available<br>OT16...40F3C in the I- and II-positions (and when padlocked).<br>| Din-rail or base mounting. 5<br>Manual change-over switches, open transition, OT16...OT125_C<br>OT63...80F3C Handle and shaft not included. See recommended accessories.<br>Rated current and power<br>No. AC-21A/AC-22A AC-23A Weight/<br>of ≤ 415V 400V 400...415V unit<br>poles I[A] S[kVA] I[A]/P[kW] Type Order number [kg]<br>i... 3 16 11 16/7.5 OT16F3C 1SCA104816R1001 2 0.25<br>OT100...125F3C 4 16 11 16/7.5 OT16F4C 1SCA104831R1001 0.31<br>3 25 17 20/9 OT25F3C 1SCA104863R1001 0.25<br>4 25 17 20/9 OT25F4C 1SCA104877R1001 0.31<br>3 40 27 23/11 OT40F3C 1SCA104913R1001 0.25<br>4 40 27 23/11 OT40F4C 1SCA104934R1001 0.31<br>3 63 43 45/22 OT63F3C 1SCA105338R1001 0.64<br>4 63 43 45/22 OT63F4C 1SCA105369R1001 0.70<br>3 80 55 75/37 OT80F3C 1SCA105402R1001 0.64<br>4 80 55 75/37 OT80F4C 1SCA105418R1001 0.70<br>3 100 70 80/37 OT100F3C 1SCA105008R1001 0.90<br>4 100 70 80/37 OT100F4C 1SCA105019R1001 1.18<br>3 125 86 90/45 OT125F3C 1SCA105037R1001 0.90<br>UL 4 125 86 llC—E>E>EEEEeeeee 90/45 OT125F4C 1SCA105054R1001 1.18<br>Cable cross section of the change-over switches<br>Direct operation: Suitable for switches Cable cross section [mm [2] ]<br>OT16...40F_C 0.75 … 10<br>OT63...80F_C 1.5 … 35<br>OT100...125F_C 10 … 70<br>OHBS3<br>OHBS9 Recommended accessories: Handles and shafts<br>Suitable Operating<br>for switches type Handle type Order number Shaft type Order number<br>External operation: OT16…40F_C Direct operation OHBS3 1SCA108320R1001 – –<br>OT63…125F_C Direct operation OHBS9 1SCA108665R1001 – –<br>OT16…125F_C Selector handle (external) OHBS2AJE011 1SCA105220R1001 OXS6X120 1SCA101654R1001<br>OT16…125F_C Pistol handle (external) OHB45J6E311 1SCA022817R2130 OXP6X170 1SCA108224R1001<br>OHBS2AJE011<br>OHB45J6E311<br>**----- End of picture text -----**<br> > 1 Roll over the picture to zoom in. > 2 Click on the product order code to obtain detailed information and agreements. **==> picture [139 x 5] intentionally omitted <==** **----- Start of picture text -----**<br> Transfer, change-over and bypass switches | 1SCC303003C0201 | 19<br>**----- End of picture text -----**<br> Transfer, change-over and bypass switches Securing your power to perform |**Transfer, change-over and bypass switches**|| |---|---| |Description and typical applications|4| |**Manual change-over switches**|| |General information|10| |Orderinginformation|18| |Dimension drawings|28| |Optional accessories|34| |**Motorized change-over switches**|| |General information|46| |Orderinginformation|54| |Dimension drawings|62| |Optional accessories|66| |**Automatic transfer switches**|| |General information|78| |Orderinginformation|87| |Dimension drawings|90| |Optional accessories|94| |**Manual and motorized bypass switches**|| |General information|104| |Orderinginformation|110| |Dimension drawings|114| |Optional accessories|116| |**Index**|| |List ofproducts withpage number in alphabetical order|122| Transfer, change-over and bypass switches | 1SCC303003C0201 | 3 # 4 | 1SCC303003C0201 | Transfer, change-over and bypass switches A secure power supply is essential to any application relying on electricity. We offer a full range of smart, safe and reliable change-over switches for your critical applications. **==> picture [69 x 405] intentionally omitted <==** ## Comprehensive offering ABB offers a wide variety of switches to cover all your needs. A complete range from 16 to 3200 Amperes in manual, remote and automatic switches is further enhanced by vast amounts of additional accessories ranging from advanced controllers to auxiliary contacts. ## Reliable performance ABB change-over, bypass and transfer switches are designed, built and tested for the best possible performance. Switches are designed to be virtually maintenance free across their entire extended lifespan and offer reliable performance in any and all possible circumstances. Durability has been ensured by testing switches against the IEC 60947-6-1 standard. ## Smart and compact design All switches by have been designed for easy and cost-efficient installation, maintenance and use. Their modular design and smaller dimensions enable installation into smaller enclosures saving precious space and significantly reducing material, handling and installation costs. The simple design also makes use easy even without previous experience or training. ## Safe operations ABB change-over, bypass and transfer switches come equipped with a comprehensive range of inbuilt safety features such as mechanical interlock. All motorized and automatic switches can also be operated manually in emergency situations, but can also be padlocked when the handle is removed to prevent unwanted manual or remote operations or enable safe maintenance work. ## ABB product support All our switches have been built to the highest standards and are always supported by our dedicated and skilled worldwide service network. If you ever find yourself in need of immediate service or assistance, don’t hesitate to get in touch with us. With a product by ABB you are never alone. Transfer, change-over and bypass switches | 1SCC303003C0201 | 5 A smooth and safe transition from one power source to another is of the utmost importance. In case of power source failure, whether planned or unplanned, a rapid switch to back-up power is often crucial. To meet any and all of your change-over, bypass and transfer needs, we offer a wide variety of switches ranging from 16 to 3200 Amperes. ABB’s range includes switches that allow you to transfer from one source to another manually, remotely or automatically. ABB Change-over Switches for applications in all walks of life Back up power for industrial applications - Power plants - Data centers - Production plants - Farming facilities Critical lighting and air conditioning for mass transportation hubs - Airport runways - Underground railways - Car parks Ensured continuity of public services - Water pumping stations - Sewage treatment plants - Telecommunications Buildings (back up power, lighting, sprinklers, elevators etc.) - Hospitals - Shops and malls - Hotels and restaurants - Sport stadiums and arenas - Private residences 6 | 1SCC303003C0201 | Transfer, change-over and bypass switches ## Ensuring a constant power supply is critical in typical change-over switch applications ## Use in critical applications The most typical application for changeover switches is utility and stand-by generating set applications where change-over switches commutate between two sources. Often the back-up power source is a stand-by generator set. These generator sets (Gen-sets) are a fundamental part of many Critical Power applications where a constant and reliable source of electrical energy is required. ## Ensuring back-up power Change-over switches are used to switch from the grid to the back-up in case of a failure in the primary energy source. They are typically dedicated switching devices, consisting of two mechanically interlocked switch-disconnectors and a motor operator for electrical operation. The switching device may also have an integrated automatic control unit, enabling fully automatic operations. **==> picture [322 x 269] intentionally omitted <==** **----- Start of picture text -----**<br> Typical generator Transformer<br>2250kW / 11kV / 3P 12 / 16 MVA - 34,5 / 11 kV<br>G G G G G<br>MV-SG 11kV / 2000A<br>MV-SG 11kV / 2000A MV-SG 11kV / 2000A<br>LV-SG 6000A / 400V LV-SG 6000A / 400V<br>LV-SG I 2500A / 400V LV-SG II 2500A / 400V<br>— I T_———— ] |<br>a Air handling unit (AHU) - Chiller - UPS - Secondary chiller water pump (SCHWP)<br>**----- End of picture text -----**<br> Applications for change-over switches are not always between utility and generating set. They are also used to provide secondary supply for e.g. air handling units, chillers and water pumps. Transfer, change-over and bypass switches | 1SCC303003C0201 | 7 **==> picture [241 x 26] intentionally omitted <==** **----- Start of picture text -----**<br> 8 | ae 1SCC303003C0201 a aPP | Transfer, change-over and bypass switches .SF . 5<br>S<br>5aM , Pf oy # ' J<br>**----- End of picture text -----**<br> ## Manual change-over switches Open, fast and closed transition from 16 to 3200 Amperes **==> picture [258 x 444] intentionally omitted <==** **----- Start of picture text -----**<br> Introduction to manual change-over switches<br>General information 10<br>Product range 11<br>Type codes and pole configuration table 12<br>Technical data<br>OT40...125_C (IEC) 14<br>OT160...800_C (IEC) 15<br>OT1000...3200_C (IEC) 16<br>OT30...100_C (UL/CSA) 17<br>OT200...800U_C (UL/CSA) 17<br>Ordering information<br>Open transition, OT40...125_C 18<br>Open transition, OT160...800_C 20<br>Open transition, OT1000...3200_C 23<br>Fast transition, OT160...OT800_CF 25<br>Closed transition, OT160...OT800_CL 26<br>Open transition, UL/CSA, OT30...OT100_C 27<br>Open transition, UL/CSA, OT200...800U_C 27<br>Dimension drawings<br>Modular frame change-over switches 28<br>Back to back frame change-over switches 29<br>UL/CSA change-over switches 32<br>Ordering information for optional accessories<br>Handle knobs 34<br>External handles 35<br>Extended shafts 38<br>Terminal shrouds 39<br>Phase barriers 40<br>Terminal clamps 41<br>Bridging- and reversing bars 42<br>Fourth poles 42<br>Auxiliary contacts 44<br>**----- End of picture text -----**<br> ABB’s manual change-over switches provide high performance in a compact package, even in the most heavy duty applications. Transfer, change-over and bypass switches | 1SCC303003C0201 | 9 Manual change-over switches The growing importance of a secure power supply ABB offers a wide variety of manual change-over switches, from 16 to 3200 Amperes in range. Manual change-over switches are available with three different transition types; Open, fast or closed. ## Heavy duty performance Change-over switches by ABB are extremely well suited for heavy duty applications. They are equipped with CTI (comparative tracking index) of over 600 V, making them great for use in tropical environments. ## Modular and flexible The modular and flexible construction, which can even include an adjustable periscopic shaft,allows for different arrangements of the poles and handle, providing you with the opportunity to create unique space saving solutions for your customers. ## Real one pole construction Our switches come with a real one pole construction in even higher ratings (one line per power line), creating savings in terms of energy consumption by reducing power loss. A single terminal per pole across the entire range also eliminates the need to use additional fixing sets to do connections. ## UL/CSA certified performance To complement our wide range of manual change-over switches, we also offer open transition manual change-over switches designed according to UL/CSA certification standards in a power range from 30 to 800 Amperes. 10 | 1SCC303003C0201 | Transfer, change-over and bypass switches ## Manual change-over switches From 16 to 3200 Amperes ## **Manual operation, change-over switches 16-125A** |**Types**|OT16 _C|OT63 _C|OT100 _C| |---|---|---|---| ||OT25 _C|OT80 _C|OT125 _C| ||OT40 _C||| |**lth /A**|**25**<br>**32**<br>**40**|**63**<br>**80**|**115**<br>**125**| |le/AC-22A, < 415V|16<br>25<br>40|63<br>80|100<br>125| |le/AC-23A, < 415V|16<br>20<br>23|45<br>75|80<br>90| ## **Manual operation, change-over switches 160-800A** |**Types**|OT160 _C|OT160_W _C|OT315 _C|OT630 _C| |---|---|---|---|---| ||OT200 _C|OT200_W _C|OT400 _C|OT800 _C| ||OT250 _C|OT250_W _C||| |**lth /A**|**160**<br>**200**<br>**250**|**160**<br>**200**<br>**250**|**315**<br>**400**|**630**<br>**800**| |le/AC-22A, < 415V|160<br>200<br>250|160<br>200<br>250|315<br>400|630<br>800| |le/AC-23A, < 415V|160<br>200<br>250|160<br>200<br>250|315<br>400|630<br>800| |Ie/AC-31B, < 415V|160<br>200<br>250|160<br>200<br>250|315<br>400|630<br>800| ## **Manual operation, change-over switches 1000-3200A** |**Types**|OT1000 _C|OT1600 _C|OT2000 _C|OT3200 _C| |---|---|---|---|---| ||OT1250 _C||OT2500 _C|| |**lth /A**|**1000**<br>**1250**|**1600**|**2000**<br>**2500**|**3200**| |le/AC-22A, < 415V|1000<br>1250|1600||| |le/AC-23A, < 415V|1000<br>1250|1250||| |le/AC-21B, < 415V|||2000<br>2500|3200| |Ie/AC-31B, < 415V|1000<br>1250|1600|2000<br>2000|| ## **UL/CSA manual change-over switches, 30-800 A** |**Types**|OT30_C|OT60_C|OT100_C|OT200_C|OT400_C|OT600_C|OT800_C| |---|---|---|---|---|---|---|---| |**Current, general use**|**30**|**60**|**100**|**200**|**400**|**600**|**800**| |UL98, 600 V|30|60|100|200|400|600|800| |le/AC-22A, < 415V|40|63|100|250|400|800|800| Transfer, change-over and bypass switches | 1SCC303003C0201 | 11 Manual change-over switches Type codes and pole configuration table ## Type codes Understanding the type code keys below will help you quickly identify the correct product for your needs. The simple naming system allows you to see the products type, Ampere rating, standard classification and number of poles, all in one glance. ## **Explanation of the types OT16..125_C** **==> picture [258 x 350] intentionally omitted <==** **----- Start of picture text -----**<br> Option: OT40 F 3 C<br>Position: 1 2 3 4<br>1 Brand and Switch size / Ampere rating<br>2 IEC<br>3 Number of the poles<br>3: 3-poles<br>4: 4-poles<br>4 Change over switch<br>C: I-0-II -operation<br>Explanation of the types OT160...3200_C<br>Option: OT250 E 03 C - P<br>Position: 1 2 3 4 5 6<br>1 Brand and Switch size / Ampere rating<br>2 Standard<br>E: IEC<br>U: UL<br>3 Number of the poles<br>03: 12<br>04: 13<br>22: 33<br>4 Change-over switch<br>5 Operation type<br> Standard change-over switch I-0-II<br>L: Closed transition change-over switch I-I+II-II<br>F: Fast transition change-over swithc I-0-II<br>6 Included handle<br>_(blank): Handle + shaft not included<br>P: Pistol handle + shaft<br>**----- End of picture text -----**<br> - K: Direct mounted handle ## Pole configuration table The various placing options of the operating mechanism in relation to the 3 or 4 poles is illustrated below. The operating mechanism may be placed at the end of the switch or between poles. |*Configuration 03 & 04:<br>**Configuration 12 & 22:<br>03:(Without N)3-poles,operatingmechanism at the left end of the switch*<br>04:(IncludingN)4-poles, operatingmechanism at the left end of the switch*<br>12:(Without N)3-poles, operatingmechanism between thepoles**<br>22:(IncludingN)4-poles, operatingmechanism between thepoles**<br>30: 3-poles,operatingmechanism at the right end of the switch<br>40: 4-poles,operatingmechanism at the right end of the switch<br>For example:<br>N<br>N|*Configuration 03 & 04:<br>**Configuration 12 & 22:<br>03:(Without N)3-poles,operatingmechanism at the left end of the switch*<br>04:(IncludingN)4-poles, operatingmechanism at the left end of the switch*<br>12:(Without N)3-poles, operatingmechanism between thepoles**<br>22:(IncludingN)4-poles, operatingmechanism between thepoles**<br>30: 3-poles,operatingmechanism at the right end of the switch<br>40: 4-poles,operatingmechanism at the right end of the switch<br>For example:<br>N<br>N|*Configuration 03 & 04:<br>**Configuration 12 & 22:<br>03:(Without N)3-poles,operatingmechanism at the left end of the switch*<br>04:(IncludingN)4-poles, operatingmechanism at the left end of the switch*<br>12:(Without N)3-poles, operatingmechanism between thepoles**<br>22:(IncludingN)4-poles, operatingmechanism between thepoles**<br>30: 3-poles,operatingmechanism at the right end of the switch<br>40: 4-poles,operatingmechanism at the right end of the switch<br>For example:<br>N<br>N|*Configuration 03 & 04:<br>**Configuration 12 & 22:<br>03:(Without N)3-poles,operatingmechanism at the left end of the switch*<br>04:(IncludingN)4-poles, operatingmechanism at the left end of the switch*<br>12:(Without N)3-poles, operatingmechanism between thepoles**<br>22:(IncludingN)4-poles, operatingmechanism between thepoles**<br>30: 3-poles,operatingmechanism at the right end of the switch<br>40: 4-poles,operatingmechanism at the right end of the switch<br>For example:<br>N<br>N|*Configuration 03 & 04:<br>**Configuration 12 & 22:<br>03:(Without N)3-poles,operatingmechanism at the left end of the switch*<br>04:(IncludingN)4-poles, operatingmechanism at the left end of the switch*<br>12:(Without N)3-poles, operatingmechanism between thepoles**<br>22:(IncludingN)4-poles, operatingmechanism between thepoles**<br>30: 3-poles,operatingmechanism at the right end of the switch<br>40: 4-poles,operatingmechanism at the right end of the switch<br>For example:<br>N<br>N|*Configuration 03 & 04:<br>**Configuration 12 & 22:<br>03:(Without N)3-poles,operatingmechanism at the left end of the switch*<br>04:(IncludingN)4-poles, operatingmechanism at the left end of the switch*<br>12:(Without N)3-poles, operatingmechanism between thepoles**<br>22:(IncludingN)4-poles, operatingmechanism between thepoles**<br>30: 3-poles,operatingmechanism at the right end of the switch<br>40: 4-poles,operatingmechanism at the right end of the switch<br>For example:<br>N<br>N|*Configuration 03 & 04:<br>**Configuration 12 & 22:<br>03:(Without N)3-poles,operatingmechanism at the left end of the switch*<br>04:(IncludingN)4-poles, operatingmechanism at the left end of the switch*<br>12:(Without N)3-poles, operatingmechanism between thepoles**<br>22:(IncludingN)4-poles, operatingmechanism between thepoles**<br>30: 3-poles,operatingmechanism at the right end of the switch<br>40: 4-poles,operatingmechanism at the right end of the switch<br>For example:<br>N<br>N|*Configuration 03 & 04:<br>**Configuration 12 & 22:<br>03:(Without N)3-poles,operatingmechanism at the left end of the switch*<br>04:(IncludingN)4-poles, operatingmechanism at the left end of the switch*<br>12:(Without N)3-poles, operatingmechanism between thepoles**<br>22:(IncludingN)4-poles, operatingmechanism between thepoles**<br>30: 3-poles,operatingmechanism at the right end of the switch<br>40: 4-poles,operatingmechanism at the right end of the switch<br>For example:<br>N<br>N|*Configuration 03 & 04:<br>**Configuration 12 & 22:<br>03:(Without N)3-poles,operatingmechanism at the left end of the switch*<br>04:(IncludingN)4-poles, operatingmechanism at the left end of the switch*<br>12:(Without N)3-poles, operatingmechanism between thepoles**<br>22:(IncludingN)4-poles, operatingmechanism between thepoles**<br>30: 3-poles,operatingmechanism at the right end of the switch<br>40: 4-poles,operatingmechanism at the right end of the switch<br>For example:<br>N<br>N|*Configuration 03 & 04:<br>**Configuration 12 & 22:<br>03:(Without N)3-poles,operatingmechanism at the left end of the switch*<br>04:(IncludingN)4-poles, operatingmechanism at the left end of the switch*<br>12:(Without N)3-poles, operatingmechanism between thepoles**<br>22:(IncludingN)4-poles, operatingmechanism between thepoles**<br>30: 3-poles,operatingmechanism at the right end of the switch<br>40: 4-poles,operatingmechanism at the right end of the switch<br>For example:<br>N<br>N|*Configuration 03 & 04:<br>**Configuration 12 & 22:<br>03:(Without N)3-poles,operatingmechanism at the left end of the switch*<br>04:(IncludingN)4-poles, operatingmechanism at the left end of the switch*<br>12:(Without N)3-poles, operatingmechanism between thepoles**<br>22:(IncludingN)4-poles, operatingmechanism between thepoles**<br>30: 3-poles,operatingmechanism at the right end of the switch<br>40: 4-poles,operatingmechanism at the right end of the switch<br>For example:<br>N<br>N|*Configuration 03 & 04:<br>**Configuration 12 & 22:<br>03:(Without N)3-poles,operatingmechanism at the left end of the switch*<br>04:(IncludingN)4-poles, operatingmechanism at the left end of the switch*<br>12:(Without N)3-poles, operatingmechanism between thepoles**<br>22:(IncludingN)4-poles, operatingmechanism between thepoles**<br>30: 3-poles,operatingmechanism at the right end of the switch<br>40: 4-poles,operatingmechanism at the right end of the switch<br>For example:<br>N<br>N|*Configuration 03 & 04:<br>**Configuration 12 & 22:<br>03:(Without N)3-poles,operatingmechanism at the left end of the switch*<br>04:(IncludingN)4-poles, operatingmechanism at the left end of the switch*<br>12:(Without N)3-poles, operatingmechanism between thepoles**<br>22:(IncludingN)4-poles, operatingmechanism between thepoles**<br>30: 3-poles,operatingmechanism at the right end of the switch<br>40: 4-poles,operatingmechanism at the right end of the switch<br>For example:<br>N<br>N|*Configuration 03 & 04:<br>**Configuration 12 & 22:<br>03:(Without N)3-poles,operatingmechanism at the left end of the switch*<br>04:(IncludingN)4-poles, operatingmechanism at the left end of the switch*<br>12:(Without N)3-poles, operatingmechanism between thepoles**<br>22:(IncludingN)4-poles, operatingmechanism between thepoles**<br>30: 3-poles,operatingmechanism at the right end of the switch<br>40: 4-poles,operatingmechanism at the right end of the switch<br>For example:<br>N<br>N|*Configuration 03 & 04:<br>**Configuration 12 & 22:<br>03:(Without N)3-poles,operatingmechanism at the left end of the switch*<br>04:(IncludingN)4-poles, operatingmechanism at the left end of the switch*<br>12:(Without N)3-poles, operatingmechanism between thepoles**<br>22:(IncludingN)4-poles, operatingmechanism between thepoles**<br>30: 3-poles,operatingmechanism at the right end of the switch<br>40: 4-poles,operatingmechanism at the right end of the switch<br>For example:<br>N<br>N|*Configuration 03 & 04:<br>**Configuration 12 & 22:<br>03:(Without N)3-poles,operatingmechanism at the left end of the switch*<br>04:(IncludingN)4-poles, operatingmechanism at the left end of the switch*<br>12:(Without N)3-poles, operatingmechanism between thepoles**<br>22:(IncludingN)4-poles, operatingmechanism between thepoles**<br>30: 3-poles,operatingmechanism at the right end of the switch<br>40: 4-poles,operatingmechanism at the right end of the switch<br>For example:<br>N<br>N|*Configuration 03 & 04:<br>**Configuration 12 & 22:<br>03:(Without N)3-poles,operatingmechanism at the left end of the switch*<br>04:(IncludingN)4-poles, operatingmechanism at the left end of the switch*<br>12:(Without N)3-poles, operatingmechanism between thepoles**<br>22:(IncludingN)4-poles, operatingmechanism between thepoles**<br>30: 3-poles,operatingmechanism at the right end of the switch<br>40: 4-poles,operatingmechanism at the right end of the switch<br>For example:<br>N<br>N|*Configuration 03 & 04:<br>**Configuration 12 & 22:<br>03:(Without N)3-poles,operatingmechanism at the left end of the switch*<br>04:(IncludingN)4-poles, operatingmechanism at the left end of the switch*<br>12:(Without N)3-poles, operatingmechanism between thepoles**<br>22:(IncludingN)4-poles, operatingmechanism between thepoles**<br>30: 3-poles,operatingmechanism at the right end of the switch<br>40: 4-poles,operatingmechanism at the right end of the switch<br>For example:<br>N<br>N|*Configuration 03 & 04:<br>**Configuration 12 & 22:<br>03:(Without N)3-poles,operatingmechanism at the left end of the switch*<br>04:(IncludingN)4-poles, operatingmechanism at the left end of the switch*<br>12:(Without N)3-poles, operatingmechanism between thepoles**<br>22:(IncludingN)4-poles, operatingmechanism between thepoles**<br>30: 3-poles,operatingmechanism at the right end of the switch<br>40: 4-poles,operatingmechanism at the right end of the switch<br>For example:<br>N<br>N|*Configuration 03 & 04:<br>**Configuration 12 & 22:<br>03:(Without N)3-poles,operatingmechanism at the left end of the switch*<br>04:(IncludingN)4-poles, operatingmechanism at the left end of the switch*<br>12:(Without N)3-poles, operatingmechanism between thepoles**<br>22:(IncludingN)4-poles, operatingmechanism between thepoles**<br>30: 3-poles,operatingmechanism at the right end of the switch<br>40: 4-poles,operatingmechanism at the right end of the switch<br>For example:<br>N<br>N|*Configuration 03 & 04:<br>**Configuration 12 & 22:<br>03:(Without N)3-poles,operatingmechanism at the left end of the switch*<br>04:(IncludingN)4-poles, operatingmechanism at the left end of the switch*<br>12:(Without N)3-poles, operatingmechanism between thepoles**<br>22:(IncludingN)4-poles, operatingmechanism between thepoles**<br>30: 3-poles,operatingmechanism at the right end of the switch<br>40: 4-poles,operatingmechanism at the right end of the switch<br>For example:<br>N<br>N|*Configuration 03 & 04:<br>**Configuration 12 & 22:<br>03:(Without N)3-poles,operatingmechanism at the left end of the switch*<br>04:(IncludingN)4-poles, operatingmechanism at the left end of the switch*<br>12:(Without N)3-poles, operatingmechanism between thepoles**<br>22:(IncludingN)4-poles, operatingmechanism between thepoles**<br>30: 3-poles,operatingmechanism at the right end of the switch<br>40: 4-poles,operatingmechanism at the right end of the switch<br>For example:<br>N<br>N|*Configuration 03 & 04:<br>**Configuration 12 & 22:<br>03:(Without N)3-poles,operatingmechanism at the left end of the switch*<br>04:(IncludingN)4-poles, operatingmechanism at the left end of the switch*<br>12:(Without N)3-poles, operatingmechanism between thepoles**<br>22:(IncludingN)4-poles, operatingmechanism between thepoles**<br>30: 3-poles,operatingmechanism at the right end of the switch<br>40: 4-poles,operatingmechanism at the right end of the switch<br>For example:<br>N<br>N|*Configuration 03 & 04:<br>**Configuration 12 & 22:<br>03:(Without N)3-poles,operatingmechanism at the left end of the switch*<br>04:(IncludingN)4-poles, operatingmechanism at the left end of the switch*<br>12:(Without N)3-poles, operatingmechanism between thepoles**<br>22:(IncludingN)4-poles, operatingmechanism between thepoles**<br>30: 3-poles,operatingmechanism at the right end of the switch<br>40: 4-poles,operatingmechanism at the right end of the switch<br>For example:<br>N<br>N|*Configuration 03 & 04:<br>**Configuration 12 & 22:<br>03:(Without N)3-poles,operatingmechanism at the left end of the switch*<br>04:(IncludingN)4-poles, operatingmechanism at the left end of the switch*<br>12:(Without N)3-poles, operatingmechanism between thepoles**<br>22:(IncludingN)4-poles, operatingmechanism between thepoles**<br>30: 3-poles,operatingmechanism at the right end of the switch<br>40: 4-poles,operatingmechanism at the right end of the switch<br>For example:<br>N<br>N|*Configuration 03 & 04:<br>**Configuration 12 & 22:<br>03:(Without N)3-poles,operatingmechanism at the left end of the switch*<br>04:(IncludingN)4-poles, operatingmechanism at the left end of the switch*<br>12:(Without N)3-poles, operatingmechanism between thepoles**<br>22:(IncludingN)4-poles, operatingmechanism between thepoles**<br>30: 3-poles,operatingmechanism at the right end of the switch<br>40: 4-poles,operatingmechanism at the right end of the switch<br>For example:<br>N<br>N|*Configuration 03 & 04:<br>**Configuration 12 & 22:<br>03:(Without N)3-poles,operatingmechanism at the left end of the switch*<br>04:(IncludingN)4-poles, operatingmechanism at the left end of the switch*<br>12:(Without N)3-poles, operatingmechanism between thepoles**<br>22:(IncludingN)4-poles, operatingmechanism between thepoles**<br>30: 3-poles,operatingmechanism at the right end of the switch<br>40: 4-poles,operatingmechanism at the right end of the switch<br>For example:<br>N<br>N| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| |||||||||||||||||||||||||||| ||||||||||||N|||N||||||||||||| |||||||||||||||||||||||||||| 12 | 1SCC303003C0201 | Transfer, change-over and bypass switches Transfer, change-over and bypass switches | 1SCC303003C0201 | 13 ## Manual change-over switches Technical data for OT40...125_C Manual change-over switches **==> picture [527 x 602] intentionally omitted <==** **----- Start of picture text -----**<br> Switch size<br>Data according to IEC 60947-3 OT16_ OT25_ OT40_ OT63_ OT80_ OT100_ OT125_<br>Rated insulation voltage and rated Pollution V 750 750 750 750 750 750 750<br>operational voltage AC20/DC20 degree 3<br>Dielectric strength 50 Hz 1min. kV 6 6 6 6 6 6 6<br>Rated impulse withstand voltage kV 8 8 8 8 8 8 8<br>Rated thermal current and rated / ambient 40°C In open air A 25 32 40 63 80 115 125<br>operational current AC20/DC20 / ambient 40°C In enclosure A 25 32 40 63 80 115 125<br>/ ambient 60°C In enclosure A 20 25 32 50 63 80 100<br>..with minimum conductor cross section Cu mm [2] 4 6 10 16 25 35 50<br>Rated operational current, AC-21A up to 500 V A 16 25 40 63 80 100 125<br>690 V A 16 25 40 63 80 100 125<br>Rated operational current, AC-22A up to 500 V A 16 25 40 63 80 100 125<br> 690 V A 16 25 40 63 80 100 125<br>Rated operational current, AC-23A up to 415 V A 16 20 23 45 75 80 90<br>440 V A 16 20 23 45 65 65 78<br>500 V A 16 20 23 45 58 60 70<br>690 V A 10 11 12 20 20 40 50<br>Rated operational current / poles in series, DC-21A up to 48 V [1)] A 16/1 25/1 32/1 63/1 80/1 100/1 125/1<br>110 V A 16/2 25/2 32/2 63/2 80/2 100/2 125/2<br>220 V A 16/3 25/3 32/3 63/4 63/4 100/4 100/4<br>440 V A 16/4 16/4 16/4 16/4 16/4<br>500 V A 16/4 16/4 16/4 16/4 16/4<br>Rated operational current / poles in series, DC-22A up to 48 V [1)] A 16/1 25/1 32/1 63/1 80/1 100/1 125/1<br>110 V A 16/2 25/2 32/2 63/2 80/2 100/2 125/2<br>220 V A 16/3 25/3 32/4 45/4 45/4 63/4 80/4<br>440 V A 10/4 10/4 10/4 10/4 10/4<br>Rated operational current / poles in series, DC-23A up to 48 V [1)] A 16/1 25/1 32/1 63/1 80/1 100/1 125/1<br>110 V A 16/2 25/2 32/2 63/2 80/2 100/2 125/2<br>220 V A 16/4 25/4 32/4 45/4 45/4 63/4 63/4<br>440 V A 10/4 10/4 10/4 10/4 10/4<br>Rated operational power, AC-23A [2)] 230 V kW 3 4 5,5 11 22 22 22<br>The kW-ratings are accurate for 3-phase 400 V kW 7.5 9 11 22 37 37 45<br>1500 R.P.M. standard asychronous motors 415 V kW 7.5 9 11 22 37 37 45<br>500 V kW 7.5 9 11 22 37 37 45<br>690 V kW 7.5 9 11 15 18.5 37 45<br>Rated breaking capacity in category AC-23 up to 415 V A 128 160 184 360 640 640 720<br>500 V A 128 160 184 360 464 480 560<br>690 V A 80 88 96 160 160 320 400<br>Rated conditional short-circuit current Icorresponding max. allowed cut-off current îp (r.m.s.) and c (peak) Max. OFAIp (r.m.s.) 50 kA, 415 V_ fuse size gîc (peak)G/aM A/AkA 40/326.5 40/326.5 40/326.5 100/8013 100/8013 125/12516.5 125/12516.5<br>fuse manufacturers (single phase test acc. value. The cut-off current îc refers to values listed by Ip (r.m.s.) 100 kA, 500 V îc (peak) kA 17 17<br>to IEC60269). Max. OFA_ fuse size gG/aM A 100/80 100/80<br>Rated short-time withstand current I cw (r.m.s.) 690 V 1s kA 0.5 0.5 0.5 1 1.5 2.5 2.5<br>Rated short-time making capacity [3)] I cm (peak) 690 V kA 0.7 0.7 0.7 1.4 2.1 3.6 3.6<br>Power loss / pole With rated current W 0.3 0.6 1.6 2.8 4.5 4.0 6.3<br>Mechanical endurance Number of oper. cycles [4)] Cycles 10 000 10 000 10 000 10 000 10 000 10 000 10 000<br>Cable size Cu-wire size suitable mm [2] 0.75-10 0.75-10 0.75-10 1.5-35 1.5-35 10-70 10-70<br>for terminal clamps AWG 18-8 18-8 18-8 14-4 14-4 8-00 8-00<br>Terminal tightening torque Counter torque required Nm 0.8 0.8 0.8 2 2 6 6<br>Operating torque Typical for 3-pole switches Nm 1 1 1 1.2 1.2 2 2<br>Weight without accessories 3-pole switch kg 0.25 0.25 0.25 0.64 0.64 0.90 0.90<br>4-pole switch kg 0.31 0.31 0.31 0.70 0.70 1.18 1.18<br>Data according to UL508 (Listed)<br>Current A 16 25 40 60 80<br>Horsepower, 3-phase 200 V HP 3 7.5 10 15 20<br>208 V HP 3 7.5 10 15 20<br>240 V HP 5 7.5 10 15 20<br>480 V HP 10 15 20 30 40<br>600 V HP 10 20 25 30 40<br>**----- End of picture text -----**<br> - 1) Below 48 V, two poles in parallel up to OT80 are recommended particularly in polluted atmosphere - 2) These values are given for guidance and may vary according to the motor manufacturer - 3) Short circuit duration >50ms, without fuse protection - 4) Operating cycle: O - I - O - II - O 14 | 1SCC303003C0201 | Transfer, change-over and bypass switches ## Manual change-over switches Technical data for OT160...800_C Manual change-over switches **==> picture [528 x 538] intentionally omitted <==** **----- Start of picture text -----**<br> Switch size<br>Data according to IEC 60947-3 OT_160_ OT_200_ OT_250_ OT_315_ OT_400_ OT_630_ OT_800_<br>Rated insulation voltage and Pollution V 1 000 1 000 1 000 1 000 1 000 1 000 1 000<br>rated operational voltage AC20/DC20 degree 3<br>Dielectric strength 50 Hz 1min. kV 10 10 10 10 10 10 10<br>Rated impulse withstand voltage kV 12 12 12 12 12 12 12<br>Rated thermal current and / ambient 40°C In open air A 160 200 250 315 400 630 800<br>rated operational current AC20/DC20 / ambient 40°C In enclosure A 160 200 250 315 400 630 800<br>..with minimum conductor cross section Cu mm [2] 70 95 120 185 240 2x185 2x240<br>Rated operational current, AC-21A up to 500 V A 160 200 250 315 400 630 800<br>690 V A 160 200 250 315 400 630 800<br>Rated operational current, AC-22A up to 500 V A 160 200 250 315 400 630 800<br> 690 V A 160 200 250 315 400 630 800<br>Rated operational current, AC-23A up to 415 V A 160 200 250 315 400 630 800<br>440 V A 160 200 250 315 400 630 800<br>500 V A 160 200 250 315 400 630 800<br>690 V A 160 200 250 315 400 630 800<br>Rated operational current / ≤ 110 V A 160/2 200/2 250/2 315/1 [1)] 400/1 [1)] 630/1 800/1<br>poles in series, DC-21A [6)] 220 V A 160/2 200/2 250/2 315/2 [1)] 400/2 [1)] 630/1 800/1<br>440 V A 160/3 200/3 230/3 315/3 360/3 630/2 720/2<br>660 V A 160/4 200/4 200/4 315/4 315/4 630/4 [1)] 630/4 [1)]<br>Rated operational power, AC-23A [2)] 230 V kW 45 60 75 100 132 200 250<br>The kW-ratings are accurate 400 V kW 90 110 140 160 220 355 450<br>for 3-phase 1500 R.P.M. standard 415 V kW 90 110 145 180 230 355 450<br>asychronous motors 500 V kW 110 132 170 220 280 400 560<br>690 V kW 160 200 250 315 400 630 800<br>Rated breaking capacity up to 415 V A 1 280 1 600 2 000 2 520 3 200 5 040 6 400<br>in category AC-23<br>500 V A 1 280 1 600 2 000 2 520 3 200 5 040 6 400<br>690 V A 1 280 1 600 2 000 2 520 3 200 5 040 6 400<br>value. The cut-off current îvalues listed by fuse manufacturers Rated conditional short-circuit current Ip (r.m.s.) and cut-off current îc refers to c (peak) IMax. OFAIpp (r.m.s.) 80 kA, 415 V (r.m.s.) 100 kA, 500 V_ fuse size îîgcc (peak) (peak)G/aM kAkAA/A 40.540.5355/315 40.540.5355/315 40.540.5355/315 5961.5 500/500 5961.5 500/500 83.590800/1 000 83.590800/1 000<br>(single phase test acc. to IEC60269). Max. OFA_ fuse size gG/aM A 315/315 315/315 315/315 500/450 500/450 800/800 800/800<br>Ip (r.m.s.) 80 kA, 690 V îc (peak) kA 40.5 40.5 40.5 59 59 83.5 83.5<br>Max. OFA_ fuse size gG/aM A 355/315 355/315 355/315 500/500 500/500 800/1 000 800/1 000<br>Rated short-time withstand current Icw (r.m.s.) 690 V 0.15s kA 15 15 15 31 31 38 38<br>690 V 0.25s kA 15 15 15 24 24 36 36<br>690 V 1s kA 8 8 8 15 15 20 20<br>Rated short-time making capacity [3)] Icm (peak) [4)] 690 V kA 30 30 30 65 65 80 80<br>Power loss / pole With rated current W 2.4 4 6.5 6.5 10 25 40<br>Mechanical endurance Number of oper. cycles [5)] Cycles 8 000 8 000 8 000 8 000 8 000 5 000 5 000<br>Terminal bolt size Metric thread mm M8x25 M8x25 M8x25 M10x30 M10x30 M12x40 M12x40<br>diameter x length<br>Terminal tightening torque Counter torque required Nm 15-22 15-22 15-22 30-44 30-44 50-75 50-75<br>Operating torque 3-pole change-over Nm 7 7 7 16 16 27 27<br>switches<br>Weight without accessories Manual change-over 3-poles kg 2.5 2.5 2.5 4.7 4.7 12.8 12.8<br>switches 4-poles kg 3.2 3.2 3.2 5.8 5.8 15.6 15.6<br>Data according to IEC 60947-6-1<br>Class of equipment PC PC PC PC PC PC PC<br>Rated short-time withstand current Icw (r.m.s.) 690 V 0.1s kA 15 15 15 25 25 38 38<br>Rated operational current, AC-31B up to 415 V A 160 200 250 315 400 630 800<br>Rated operational current, AC-33B up to 415 V A 160 200 250 315 400 630 800<br>**----- End of picture text -----**<br> - 1) Utilization category B - 2) These values are given for guidance and may vary acc. to the motor manufacturer - 3) Short circuit duration > 50ms, without fuse protection - 4) Max. distance from switch frame to nearest busbar / cable support 150 mm - 5) Operating cycle: O - I - O - II - O - 6) Further ratings on request **1000 V ratings on request** Transfer, change-over and bypass switches | 1SCC303003C0201 | 15 ## Manual change-over switches Technical data for OT1000...3200_C ## Manual change-over switches **==> picture [527 x 480] intentionally omitted <==** **----- Start of picture text -----**<br> Switch size , OT_<br>Data according to IEC 60947-3 OT_1000_ OT_1250_ OT_1600_ OT_2000_ OT_2500_ OT_3200_<br>Rated insulation voltage and Pollution V 1 000 1 000 1 000 1 000 1 000 1 000<br>rated operational voltage AC20/DC20 degree 3<br>Dielectric strength 50 Hz 1min. kV 10 10 10 10 10 10<br>Rated impulse withstand voltage kV 12 12 12 12 12 12<br>Rated thermal current and / ambient 40°C In open air A 1 000 1 250 1 600 2 000 2 500 3 200<br>rated operational current AC20/DC20 / ambient 40°C In enclosure A<br>..with minimum conductor cross section Cu mm [2] 2x300 2x400 2x500 3x500 4x500 4x1000<br>Rated operational current, AC-21A up to 500 V A 1 000 1 250 1 600 2 000 [5 )] 2 500 [5 )] 3 200 [5 )]<br>690 V A 1 000 1 250 1 600<br>Rated operational current, AC-22A up to 500 V A 1 000 1 250 1 600<br>690 V A 1 000 1 250 1 600<br>Rated operational current, AC-23A up to 415 V A 1 000 1 250 1 250<br>440 V A 1 000 1 250 1 250<br>500 V A 1 000 1 250 1 250<br>690 V A 1 000 1 250 1 250<br>Rated operational power, AC-23A [1)] 230 V kW 315 400 400<br>The kW-ratings are accurate 400 V kW 560 710 710<br>for 3-phase 1500 R.P.M. standard 415 V kW 560 710 710<br>asychronous motors 500 V kW 710 900 900<br>690 V kW 1 000 1 200 1 200<br>Rated breaking capacity up to 415 V A 10 000 10 000 10 000<br>in category AC-23<br>500 V A 10 000 10 000 10 000<br>690 V A 10 000 10 000 10 000<br>value. The cut-off current îvalues listed by fuse manufacturers Rated conditional short-circuit current Ip (r.m.s.) and cut-off current îc refers to c (peak) IMax. OFAIpp (r.m.s.) 80 kA, 415 V (r.m.s.) 100 kA, 500 V_ fuse size îîgcc (peak) (peak)G/aM kAkAA/A 1001061 250/1 250 1001061 250/1 250 1001061 250/1 250<br>(single phase test acc. to IEC60269). Max. OFA_ fuse size gG/aM A 1 250/1 250 1 250/1 250 1 250/1 250<br>Rated short-time withstand current Icw (r.m.s.) 690 V 0.15s kA 50 50 50 50 50<br>690 V 0.25s kA 50 50 50 50 50<br>690 V 1s kA 50 50 50 55 55 65<br>Rated short-time making capacity [2)] Icm (peak) [3)] 690 V kA 92 92 92 110 110 143<br>Power loss / pole With rated current W 19 29 48 55 85 95<br>Mechanical endurance Number of oper. cycles [4)] Cycles 3 000 3 000 3 000 2 000 2 000 2 000<br>Terminal bolt size Metric thread mm M12x60 M12x60 M12x60 M12x60 M12x60 M12x100<br>diameter x length<br>Terminal tightening torque Counter torque required Nm 50-75 50-75 50-75 50-75 50-75 50-75<br>Operating torque 3-pole change-over Nm 78 78 78 78 78 80<br>switches<br>Weight without accessories Manual change-over 3-poles kg 32.3 32.3 34.8 48 48 57<br>switches 4-poles kg 40.2 40.2 43.3 60 60 72<br>Data according to IEC 60947-6-1<br>Class of equipment PC PC PC PC PC<br>Rated short-time withstand current Icw (r.m.s.) 690 V 0.1s kA 50 50 50 50 50<br>Rated operational current, AC-31B up to 415 V A 1 000 1 250 1 600 2 000 2 000<br>Rated operational current, AC-33B up to 415 V A 1 000 1 000 1 000<br>**----- End of picture text -----**<br> - 1) These values are given for guidance and may vary acc. to the motor manufacturer - 2) Short circuit duration > 50ms, without fuse protection - 3) Max. distance from switch frame to nearest busbar / cable support 150 mm - 4) Operating cycle: O - I - O - II - O - 5) Category AC-21B, up to 415V **1000 V ratings on request** 16 | 1SCC303003C0201 | Transfer, change-over and bypass switches ## Manual change-over switches Technical data for UL/CSA switches OT30...100_C, OT200...800U_C UL/CSA manual change-over switches **==> picture [538 x 458] intentionally omitted <==** **----- Start of picture text -----**<br> Switch size<br>Data according to UL and CSA OT30_ OT60_ OT100_ OT200U_ OT400U_ OT600U_ OT800U_<br>Standards UL98 UL98 UL98 UL98 UL98 UL98 UL98<br>CSA 22.2#4 CSA 22.2#4 CSA 22.2#4 CSA 22.2#4 CSA 22.2#4 CSA 22.2#4 CSA 22.2#4<br>General use ratings, 1- or 3-phase V A 600 600 600 600 600 600 600<br>ratings 30 60 100 200 400 600 800<br>Horsepower, 3-phase ratings 240V HP 10 20 30 75 125 200 250<br>480V HP 20 40 50 150 250 450 500<br>600V HP 30 40 50 200 350 500 500<br>Short-circuit ratings Required protection Circuit breaker kA 14 25 35 42<br>Class J/L fuse kA 50 / - 50 / - 50 / - 65/100 100 100 100<br>…fuse size A 60 150 150 400/200 600 800 800<br>Class RK5 fuse kA 100<br>…fuse size A 600<br>Data according to IEC 60947-3<br>Rated insulation voltage and rated<br>Pollution degree 3 V 750 750 750 1 000 1 000 1 000 1 000<br>operational voltage AC20/DC20<br>Dielectric strength 50 Hz 1min. kV 6 6 6 10 10 10 10<br>Rated impulse withstand voltage kV 8 8 8 12 12 12 12<br>Rated thermal current and rated / ambient 40°C In open air A 40 63 100 250 400 800 1600<br>operational current AC20/DC20<br>..with minimum conductor cross Cu AWG/ 14 - 4 14 - 4 8 - 1/0 120 240 2x240 2x500<br>section mm [2]<br>Rated operational current, AC-21A up to 690 V A 40 63 100 250 400 800 1 600<br>Rated operational current, AC-22A up to 500 V A 40 63 100 250 400 800 1 600<br>690 V A 40 63 100 250 400 800 1 600<br>Rated operational current, AC-23A up to 500 V A 40 63 60 250 400 800 1 250<br>690 V A 40 40 40 250 400 800 1 250<br>Rated conditional short-circuit current Ip (r.m.s.) and Max. OFAIp (r.m.s.) : 100 kA, 500 V_ fuse size gîc (peak)G/aM kAA 40.5315/315 61.5 500/450 90800/800 1061 250/1 250<br>corresponding max. allowedcut-off current îc peak value [1)] Ip (r.m.s.) : 80 kA, 690 V îc (peak) kA 40.5 59 83,5<br>Max. OFA_ fuse size gG/aM A 355/315 500/500 800/1 000<br>Rated short-time withstand current Icw (r.m.s.) 690V, 1s kA 2.5 2.5 2.5 8 15 20 50<br>Rated short-circuit making capacity Icm (peak) 690V kA 3.6 3.6 3.6 30 65 80 92<br>Mechanical endurance Number of operating cycles [2)] Cycles 6000 6000 6000 8 000 8 000 5 000 3 000<br>Terminal bolt size Metric thread diameter x mm M8x25 M10x30 M12x40 M12x60<br>length<br>Terminal tightening torque Counter torque required Nm 15...22 30...44 50...75 50...75<br>Operating torque 3-pole switches Nm 2 2 2 7 16 27 78<br>Weight without accessories 3-pole switch kg 0.90 0.90 0.90 2.8 5.0 13.1 34.8<br>4-pole switch kg 1.18 1.18 1.18 3.5 6.1 15.9 43.3<br>Data according to IEC 60947-6-1<br>Class of equipment PC 15 PC 25 PC 38 PC 50<br>Icw (r.m.s.) 690 V 0.1s<br>Rated short-time withstand current<br>Rated operational current, AC-31B up to 415 V A 250 400 800 1 600<br>Rated operational current, AC-33B up to 415 V A 250 400 800 1 000<br>**----- End of picture text -----**<br> - 1) The fuse in single-phase test according to IEC 60269 - 2) Operating cycle: O - I - O - II - O Transfer, change-over and bypass switches | 1SCC303003C0201 | 17 Manual change-over switches Ordering information for OT16...OT125_C 3 6 1 4 5 4 5 7 Tk 10 9 8 2 =e 11 Manual change-over switch accessory guide 1. Manual change-over switch 7. Selector handle, black or red/yellow 2. Extended shaft 8. Direct handle knob 3. Terminal clamp 9. Pistol handle, black or red/yellow 4. Fourth pole 10. Conversion kit 5. Auxiliary contact 11. Parallel connection kit 6. Terminal shroud Please note that listed accessories are not automatically included in your order. See next page for recommendations. —— 18 | 1SCC303003C0201 | Transfer, change-over and bypass switches Manual change-over switches Ordering information for OT16...OT125F_C **==> picture [42 x 73] intentionally omitted <==** **----- Start of picture text -----**<br> OT16...40F3C<br>rs<br>**----- End of picture text -----**<br> OT16...40F3C ## Open transition Simple I-O-II –operation where the handle is padlockable in O-position and door interlock available in the I- and II-positions (and when padlocked). Din-rail or base mounting. Manual change-over switches, open transition, OT16...OT125F_C Handle and shaft not included. See recommended accessories. OT63...80F3C OT100...125F3C Direct operation: OHBS3 OHBS9 |**No.**<br>**of**<br>**poles**|**Rated current and power**|**Rated current and power**|**Rated current and power**|**Type**|**Order number**|**Weight/**<br>**unit**<br>**[kg]**| |---|---|---|---|---|---|---| ||**AC-21A/AC-22A**||**AC-23A**|||| ||**≤ 415V**<br>**I[A]**|**400V**<br>**S[kVA]**|**400...415V**<br>**I[A]/P[kW]**|||| |3|16|11|16/7.5|OT16F3C|1SCA104816R1001|0.25| |4|16|11|16/7.5|OT16F4C|1SCA104831R1001|0.31| |3|25|17|20/9|OT25F3C|1SCA104863R1001|0.25| |4|25|17|20/9|OT25F4C|1SCA104877R1001|0.31| |3|40|27|23/11|OT40F3C|1SCA104913R1001|0.25| |4|40|27|23/11|OT40F4C|1SCA104934R1001|0.31| |3|63|43|45/22|OT63F3C|1SCA105338R1001|0.64| |4|63|43|45/22|OT63F4C|1SCA105369R1001|0.70| |3|80|55|75/37|OT80F3C|1SCA105402R1001|0.64| |4|80|55|75/37|OT80F4C|1SCA105418R1001|0.70| |3|100|70|80/37|OT100F3C|1SCA105008R1001|0.90| |4|100|70|80/37|OT100F4C|1SCA105019R1001|1.18| |3|125|86|90/45|OT125F3C|1SCA105037R1001|0.90| |4|125|86|90/45|OT125F4C|1SCA105054R1001|1.18| Cable cross section of the change-over switches External operation: |Cable cross section of the change-over switchesge-over switchese-over switches|| |---|---| |**Suitable for switches**|**Cable cross section [mm2]**| |OT16...40F_C|0.75 … 10| |OT63...80F_C|1.5 … 35| |OT100...125F_C|10 … 70| Recommended accessories: Handles, shafts and parallel connection kit OHBS2AJE011 |**Suitable**<br>**for switches**|**Operating**<br>**type**|**Handle type**|**Order number**|**Shaft type**|**Order number**| |---|---|---|---|---|---| |OT16…40F_C|Direct operation|OHBS3|1SCA108320R1001|–|–| |OT63…125F_C|Direct operation|OHBS9|1SCA108665R1001|–|–| |OT16…125F_C|Selector handle (external)|OHBS2AJE011|1SCA105220R1001|OXS6X120|1SCA101654R1001| |OT16…125F_C|Pistol handle (external)|OHB45J6E311|1SCA022817R2130|OXP6X170|1SCA108224R1001| **==> picture [50 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> OHB45J6E311<br>**----- End of picture text -----**<br> ## Parallel connection kits Finger protected connection bars for parallel connection of the upper or lower terminals. The bars accept additional cables, the maximum size is stated below. OZXA38 **==> picture [29 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> OZXA32<br>**----- End of picture text -----**<br> |**Suitable**<br>**for**<br>**switches**|**Cable cross**<br>**section**<br>**[mm2]**|**Type**|**Order number**|**Units/**<br>**type**<br>**[pcs]**|**Weight/**<br>**unit**<br>**[kg]**| |---|---|---|---|---|---| |OT16…40F3C|6 (fine stranded), 10 (stranded)|OZXA33|1SCA022685R0310|1|0.02| |OT16…40F4C|6 (fine stranded), 10 (stranded)|OZXA32|1SCA022683R4110|1|0.03| |OT63…80F3C|25|OZXA38|1SCA022785R2140|1|0.06| |OT63…80F4C|25|OZXA39|1SCA022790R3820|1|0.09| |OT100…125F3C|50|OZXA40|1SCA022790R3910|1|0.16| |OT100…125F4C|50|OZXA41|1SCA022790R4040|1|0.24| Transfer, change-over and bypass switches | 1SCC303003C0201 | 19 ## Manual change-over switches Ordering information for OT160...OT800_C, OT200...OT600U_C **==> picture [343 x 420] intentionally omitted <==** **----- Start of picture text -----**<br> 4<br>4<br>7<br>7<br>|<br>3 Whi<br>©) 8<br>wing<br>9<br>1<br>3<br>§<br>_ . 6<br>5<br>2<br>**----- End of picture text -----**<br> ## Manual change-over switch accessory guide 1. Manual change-over switch 6. Direct mount handle* 2. Extended shaft 7. Bridging bar 3. Auxiliary contact 8. Terminal clamp 4. Terminal shroud 9. Voltage sensing connector 5. Pistol handle Please note that not all listed accessories are automatically included in your order. See next page for recommendations. 20 | 1SCC303003C0201 | Transfer, change-over and bypass switches Manual change-over switches Ordering information for OT160...OT250_C ## Open transition OT160...250E03CP OT160...250E03WCP OT160...250E04CP OT160...250E04WCP OT160...250E33CP Simple I-O-II –operation where the handle is padlockable in O-position and door interlock available in the I- and II-positions (and when padlocked). Manual change-over switches, open transition, OT160...OT250_CP Delivered with a black plastic IP65 I-0-II pistol handle (see the table below), shaft and bolt set for the cable connection. 1000V versions available on request. |**No.**<br>**of**<br>**poles**<br>Types -W: with wide phase distance.|**AC-21A/AC-22A**<br>**≤ 415V**<br>**I[A]**<br>Types -W: with wide phase distance.|**AC-21A/AC-22A**<br>**400V**<br>**S[kVA]**<br>Types -W: with wide phase distance.|**AC-23A**<br>**400...415V**<br>**I[A]/P[kW]**|**Type**|**Order number**|**Weight/**<br>**unit**<br>**[kg]**| |---|---|---|---|---|---|---| |3|160|110|160/90|OT160E03CP|1SCA022772R6510|3.3| |3|160|110|160/90|OT160E03WCP|1SCA022772R8210|3.6| |4|160|110|160/90|OT160E04CP|1SCA022775R9440|4.1| |4|160|110|160/90|OT160E04WCP|1SCA022775R0220|4.4| |3|200|135|200/110|OT200E03CP|1SCA022771R7520|3.3| |3|200|135|200/110|OT200E03WCP|1SCA022772R8720|3.6| |4|200|135|200/110|OT200E04CP|1SCA022771R7280|4.1| |4|200|135|200/110|OT200E04WCP|1SCA022775R0650|4.4| |3|250|170|250/140|OT250E03CP|1SCA022771R3450|3.3| |3|250|170|250/140|OT250E03WCP|1SCA022772R8300|3.6| |4|250|170|250/140|OT250E04CP|1SCA022775R4640|4.1| |4|250|170|250/140|OT250E04WCP|1SCA022775R0810|4.4| |4|250|170|250/140|OT250E13CP|1SCA022777R0330|4.1| |6|250|170|250/140|OT250E33CP|1SCA118551R1001|5.7| |6|250|170|250/140|OT250E33WCP|1SCA118608R1001|6.0| Shafts, handle and bolt kits included as standard OT160...250E33WCP |**Suitable for switches**|**Shaft**|**Handle**|**Bolt kit**| |---|---|---|---| |OT160...250_C|OXP6x161|OHB65J6E011|M8x25| Recommended accessories: Bridging bars OXP6X150_161 Bridging bars are an easy and cost-efficient way to make load side connections. |**Suitable for switches**|**No. of poles**|**Type**|**Order number**|**Units/ type pcs**|**Weight / unit**| |---|---|---|---|---|---| |OT160…250_C|3|OTZC13|1SCA022767R6910|3|0.5| |OT160…250_C|4|OTZC14|1SCA022767R7040|4|0.8| OHB65J6E011 OTZC13 Transfer, change-over and bypass switches | 1SCC303003C0201 | 21 ## Manual change-over switches Ordering information for OT315...OT800_C ## Open transition Simple I-O-II –operation where the handle is padlockable in O-position and door interlock available in the I- and II-positions (and when padlocked). OT315...400E03CP Manual change-over switches, open transition, OT315...OT800_CP Delivered with a black plastic IP65 I-0-II pistol handle (see the table below), shaft and bolt set for the cable connection. OT315...400E13CP OT315...400E33CP OT630...800E03CP OT630...800E04CP OT630...800E33CP |3|315|215|315/160|OT315E03CP|1SCA022772R6780|5.9| |---|---|---|---|---|---|---| |3|315|215|315/160|OT315E12CP|1SCA022776R9910|5.9| |4|315|215|315/160|OT315E04CP|1SCA022775R7150|7.1| |4|315|215|315/160|OT315E13CP|1SCA022777R0410|7.1| |6|315|215|315/160|OT315E33CP|1SCA118635R1001|9.5| |3|400|275|400/220|OT400E03CP|1SCA022771R8500|5.9| |3|400|275|400/220|OT400E12CP|1SCA022776R9590|5.9| |4|400|275|400/220|OT400E04CP|1SCA022771R8680|7.1| |4|400|275|400/220|OT400E13CP|1SCA022777R0500|7.1| |6|400|275|400/220|OT400E33CP|1SCA118629R1001|9.5| |3|630|435|630/355|OT630E03CP|1SCA022785R6050|17.7| |3|630|435|630/355|OT630E12CP|1SCA022785R8690|17.7| |4|630|435|630/355|OT630E04CP|1SCA022785R6130|21| |4|630|435|630/355|OT630E13CP|1SCA022785R9070|21| |6|630|435|630/355|OT630E33CP|1SCA118652R1001|27.6| |3|800|550|800/450|OT800E03CP|1SCA022785R6300|17.7| |3|800|550|800/450|OT800E12CP|1SCA022785R8850|17.7| |4|800|550|800/450|OT800E04CP|1SCA022785R6210|21| |4|800|550|800/450|OT800E13CP|1SCA022785R9230|21| |6|800|550|800/450|OT800E33CP|1SCA118649R1001|27.6| 1000V versions available on request Shafts, handle and bolt kits included as standard OXP12X185 |**Suitable for switches**|**Shaft**|**Handle**|**Bolt kit**| |---|---|---|---| |OT315...400_C|OXP12x166|OHB95J12E011|M10x30| |OT630...800_C|OXP12x185|OHB125J12E011|M12x40| ## Recommended accessories: Bridging bars OHB125J12E011 |**Suitable**<br>**for switches**|**No.**<br>**of poles**|**Type**|**Order number**|**Units/**<br>**type [pcs]**|**Weight/**<br>**unit [kg]**| |---|---|---|---|---|---| |OT315…400_C|3|OTZC23|1SCA022767R7120|3|0.6| |OT315…400_C|4|OTZC24|1SCA022767R7210|4|0.8| |OT315…400_C|3|OTZC33|1SCA022767R7020|3|1| |OT315…400_C|4|OTZC34|1SCA022767R7110|4|1.3| OTZC23 22 | 1SCC303003C0201 | Transfer, change-over and bypass switches Manual change-over switches Ordering information for OT1000...OT3200_C, OT800U_C **==> picture [338 x 414] intentionally omitted <==** **----- Start of picture text -----**<br> 4<br>4<br>7<br>. \<br>| |<br>ee<br>— ( |<br>8<br>1.<br>1 a<br>RK EM 3<br>6<br>5<br>2<br>**----- End of picture text -----**<br> ## Manual change-over switch accessory guide 1. Manual change-over switch 5. Pistol handle 2. Extended shaft 3. Auxiliary contact 4. Terminal shroud 6. Direct mount handle* 7. Bridging bar 8. Voltage sensing connector Please note that not all listed accessories are automatically included in your order. See next page for recommendations. *) Optional handle types available. Please see Accessories for more details. Transfer, change-over and bypass switches | 1SCC303003C0201 | 23 ## Manual change-over switches Ordering information for OT1000...OT3200E_C ## Open transition OT1250E03CP Simple I-O-II –operation where the handle is padlockable in O-position and door interlock available in the I- and II-positions (and when padlocked). OT1000...1250E22CP Manual change-over switches, open transition, OT1000...OT3200_C Delivered with a black plastic IP65 I-0-II pistol handle (see the table below), shaft and bolt set for the cable connection. OT1600E03CP OT2000...2500E03CP OT3200E03CP |3|1000|680|1000/560|OT1000E03CP|1SCA022872R1680|48| |---|---|---|---|---|---|---| |4|1000|680|1000/560|OT1000E04CP|1SCA022872R1500|60| |4|1000|680|1000/560|OT1000E22CP|1SCA103289R1001|60| |3|1250|850|1250/710|OT1250E03CP|1SCA022872R0790|48| |4|1250|850|1250/710|OT1250E04CP|1SCA022872R1250|60| |4|1250|850|1250/710|OT1250E22CP|1SCA103311R1001|60| |3|1600|1000|1250/710|OT1600E03CP|1SCA022872R1840|51| |4|1600|1000|1250/710|OT1600E04CP|1SCA022872R2310|63| |4|1600|1000|1250/710|OT1600E22CP|1SCA103303R1001|63| |3|2000|1350||OT2000E03CP|1SCA103908R1001|70| |4|2000|1350||OT2000E04CP|1SCA103912R1001|86| |4|2000|1350||OT2000E22CP|1SCA103953R1001|86| |3|2500|1700||OT2500E03CP|1SCA105615R1001|70| |4|2500|1700||OT2500E04CP|1SCA103906R1001|86| |4|2500|1700||OT2500E22CP|1SCA103902R1001|86| |3|3200|2170||OT3200E03CP|1SCA129156R1001|79| |4|3200|2170||OT3200E04CP|1SCA129158R1001|97| |4|3200|2170||OT3200E22CP|1SCA131131R1001|97| 1) OT2000…3200: Category AC-21B 1000V versions available on request Shafts, handle and bolt kits included as standard OXP12X185 |**Suitable for switches**|**Shaft**|**Handle**|**Bolt kit**| |---|---|---|---| |OT1000...2500_C|OXP12x185|OHB200J12PE011|M12x60| |OT3200_C|OXP12x185|OHB200J12PE011|M12x100| OHB200J12PE011 ## Recommended accessories: Bridging bars OTZC44 |**Suitable for switches**|**No.**<br>**of poles**|**Type**|**Order number**|**Units/**<br>**type [pcs]**|**Weight/**<br>**unit [kg]**| |---|---|---|---|---|---| |OT1000…1250_C|4|OTZC44|1SCA022868R0800|4|5.6| |OT1600_C|4|OTZC54|1SCA022767R1010|4|7.4| |OT2000…2500_C|4|OTZC64|1SCA022868R1360|4|14.4| |OT_3200E_C|4|OTZC74|1SCA128844R1001|4|18.7| 24 | 1SCC303003C0201 | Transfer, change-over and bypass switches ## Manual change-over switches Ordering information for OT160...OT800_CF ## Fast transition OT160...250E03CFP Faster I-O-II –operation with no padlocking opportunity or interlocking. 90° operating angle for fast switching and minimized OFF-time between transfer from I-II or II-I (as low as 20ms). Manual change-over switches, fast transition, OT160...OT800_CF Delivered with a black plastic IP65 I-0-II pistol handle (see the table below), shaft and bolt set for the cable connection. Handle not padlockable and no door interlocking. OT160...250E03WCFP OT315...400E13CFP OT630...800E03CFP |3|160|110|160/90|OT160E03CFP|1SCA106086R1001|3.3| |---|---|---|---|---|---|---| |3|160|110|160/90|OT160E03WCFP|1SCA108484R1001|3.6| |4|160|110|160/90|OT160E04CFP|1SCA108489R1001|4.1| |4|160|110|160/90|OT160E04WCFP|1SCA108492R1001|4.4| |3|200|135|200/110|OT200E03CFP|1SCA108520R1001|3.3| |3|200|135|200/110|OT200E03WCFP|1SCA107578R1001|3.6| |4|200|135|200/110|OT200E04CFP|1SCA108528R1001|4.1| |4|200|135|200/110|OT200E04WCFP|1SCA108531R1001|4.4| |3|250|170|250/140|OT250E03CFP|1SCA108591R1001|3.3| |3|250|170|250/140|OT250E03WCFP|1SCA107577R1001|3.6| |4|250|170|250/140|OT250E04CFP|1SCA108600R1001|4.1| |4|250|170|250/140|OT250E04WCFP|1SCA108606R1001|4.4| |3|315|215|315/160|OT315E03CFP|1SCA108629R1001|5.9| |4|315|215|315/160|OT315E04CFP|1SCA114535R1001|7.1| |3|400|275|400/220|OT400E03CFP|1SCA106360R1001|5.9| |4|400|275|400/220|OT400E04CFP|1SCA108650R1001|7.1| |3|630|435|630/355|OT630E03CFP|1SCA106915R1001|17.7| |4|630|435|630/355|OT630E04CFP|1SCA108753R1001|21| |3|800|550|800/450|OT800E03CFP|1SCA106916R1001|17.7| |4|800|550|800/450|OT800E04CFP|1SCA106945R1001|21| OXP12X185 Shafts, handle and bolt kits included as standard **Suitable for switches Shaft Handle Bolt kit** OT160...250_CF OXP6x161 OHB65J6E69 M8x25 OT315...400_CF OXP12x166 OHB95J12E69 M10x30 eo ~~i~~ OT630...800_CF OXP12x185 OHB145J12E69 M12x40 OHB65J6E69 ~~— |~~ come OHB95J12E69 Transfer, change-over and bypass switches | 1SCC303003C0201 | 25 ## Manual change-over switches Ordering information for OT160...OT800_CL ## Closed transition ## OT160…250E03CLP wo ## OT160…250E03WCLP I – I+II – II –operation, or closed transition, means that there is no OFF-position. There is a I+II –position between I and II, in which both switches are closed simultaneously. I and II, in which both switches are closed simultaneously. Manual change-over switches, closed transition, OT160...OT800_CL Delivered with a black plastic IP65 I - I+II - II pistol handle (see the table below), shaft and bolt set for the cable connection. i OT315...400E03CLP OT630…800E03CLP OXP12X185 |3|160|110|160/90|OT160E03CLP|1SCA108468R1001|3.3| |---|---|---|---|---|---|---| |3|160|110|160/90|OT160E03WCLP|1SCA108486R1001|3.6| |4|160|110|160/90|OT160E04CLP|1SCA108491R1001|4.1| |4|160|110|160/90|OT160E04WCLP|1SCA108494R1001|4.4| |3|200|135|200/110|OT200E03CLP|1SCA108522R1001|3.3| |3|200|135|200/110|OT200E03WCLP|1SCA108525R1001|3.6| |4|200|135|200/110|OT200E04CLP|1SCA108530R1001|4.1| |4|200|135|200/110|OT200E04WCLP|1SCA108532R1001|4.4| |3|250|170|250/140|OT250E03CLP|1SCA108593R1001|3.3| |3|250|170|250/140|OT250E03WCLP|1SCA107576R1001|3.6| |4|250|170|250/140|OT250E04CLP|1SCA108605R1001|4.1| |4|250|170|250/140|OT250E04WCLP|1SCA108607R1001|4.4| |3|315|215|315/160|OT315E03CLP|1SCA108630R1001|5.9| |4|315|215|315/160|OT315E04CLP|1SCA106404R1001|7.1| |3|400|275|400/220|OT400E03CLP|1SCA108641R1001|5.9| |4|400|275|400/220|OT400E04CLP|1SCA106405R1001|7.1| |3|630|435|630/355|OT630E03CLP|1SCA106917R1001|17.7| |4|630|435|630/355|OT630E04CLP|1SCA106947R1001|21| |3|800|550|800/450|OT800E03CLP|1SCA106928R1001|17.7| |4|800|550|800/450|OT800E04CLP|1SCA106952R1001|21| 1) 1000...2500 available on request OHB65J6E65 Shafts, handles and bolt kits included as standard |**Suitable for switches**|**Shaft**|**Handle**|**Bolt kit**| |---|---|---|---| |OT160...250_CL|OXP6x161|OHB65J6E65|M8x25| |OT315...400_CL|OXP12x166|OHB95J12E65|M10x30| |OT630...800_CL|OXP12x185|OHB145J12E65|M12x40| OHB95J12E65 OHB145J12E65 26 | 1SCC303003C0201 | Transfer, change-over and bypass switches ## Manual change-over switches Ordering information for UL/CSA OT30…100_C, OT200...800U_C ## Open transition Double-throw switch for use in optional standby system. Simple I-O-II –operation where the handle is padlockable in O-position and door interlock available in the I- and II-positions (and when padlocked). **==> picture [56 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> OT100...125F3C<br>**----- End of picture text -----**<br> UL/CSA manual change-over switches, open transition, OT30…100_C, OT200...800_C The change-over switches are delivered with a black handle IP65, Nema type 1, 3R, 12, a shaft and a bolt set for the cable connection and a set of phase separators. OT200U03CP OT400U04CP |**No.**<br>**of**<br>**poles**|**UL98**<br>**600V**<br>**general**<br>**use**<br>**[A]**|**Rated**<br>**current**<br>**IEC60947-3**<br>**≤ 415 V**<br>**AC-21-22A**<br>**[A]**|**Rated**<br>**current**<br>**IEC60947-6-1**<br>**≤ 415V**<br>**AC-31B/**<br>**AC-33B**<br>**[A]**|**Type**|**Order number**|**Units/**<br>**type**<br>**[pcs]**|**Weight/**<br>**unit**<br>**[kg]**| |---|---|---|---|---|---|---|---| |3|30|40/40||OT30F3C|1SCA105071R1001|1|0.9| |4|30|40/40||OT30F4C|1SCA146051R1001|1|1.18| |3|60|63/63||OT60F3C|1SCA105078R1001|1|0.9| |4|60|63/63||OT60F4C|1SCA146053R1001|1|1.18| |3|100|100/80||OT100F3C|1SCA105008R1001|1|0.9| |4|100|100/80||OT100F4C|1SCA105019R1001|1|1.2| |3|200|250|250/250|OT200U03CP|1SCA022771R5910|1|3.6| |4|200|250|250/250|OT200U04CP|1SCA022771R6210|1|4.4| |3|400|400|400/400|OT400U03CP|1SCA022771R2810|1|6.2| |4|400|400|400/400|OT400U04CP|1SCA022771R2300|1|8.1| |3|600|800|800/800|OT600U03CP|1SCA022785R5320|1|17.9| |4|600|800|800/800|OT600U04CP|1SCA022785R5410|1|21| |3|800|800|1600/1000|OT800U03CP|1SCA104031R1001|1|51| |4|800|800|1600/1000|OT800U04CP|1SCA104036R1001|1|63| ## Shafts, handles and bolt kits included as standard The handles are equipped with door interlock function in both I- and II-position and when padlocked. Padlocking possibility in O-position with 3 padlocks, bail dia Ø 5...10 mm. Indication I-O-II. Nema type 1, 3R, 12. OT30...100F_C Handle and Shaft are not included in standard delivery. OT600U03CP |**Suitable for switches**|**Shaft**|**Handle**|**Bolt kit**| |---|---|---|---| |OT200U_|OXP6x161|OHB65J6E011|M8x25| |OT400U_|OXP12x166|OHB95J12E011|M10x30| |OT600U_|OXP12x185|OHB125J12E011|M12x40| |OT800U_|OXP12X185|OHB200J12PE011|M12x60| **==> picture [46 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> OT800U03CP<br>**----- End of picture text -----**<br> Transfer, change-over and bypass switches | 1SCC303003C0201 | 27 ## Modular change-over switches Dimensional drawings **==> picture [477 x 620] intentionally omitted <==** **----- Start of picture text -----**<br> OT16…40F_C<br>EN 50022 OA1G01 OTS40T3<br>11 57 11 11 OTS40T1<br>40 29,5 OTPS40FP<br>OH_45J6 _ OA1G10 5,4<br>12<br>35 27 15<br>¯66 0 OFF 6,3<br>35 54 ONI ONII 37 40 [60]<br>68<br>45<br>36 45 6 12 4037 2,5 2 11 13 22 13 1022 13 11 ¿4,56 70 (3-pole)15<br>tt: L P|] | [Les | 96 (4-pole) |<br>OT63…80F_C<br>EN 50022 OA1G01 OTS63T3<br>11 73,545,5 48 17,5 17,5 OTS63T1OA1G10<br>OTPS80FP 9<br>OH_45J6 45 15<br>16 14<br>0 OFF 10<br>Ø66<br>35 72,5 ONI ONII 37 54 [82,5]<br>91,5<br>45<br>36 45 6 12 L 5843,5 5,0 2 11 43,56 9 10 43,5 11 ø4,5 140 (4-pole)105 (3-pole)<br>| 17,5 [7 17,5<br>OT100…125F_C<br>11 75 55 EN 500223,3 OA1G01 63 ¿4,5 22,5 22,5 OTS125T3OA1G10 OTS125T1<br>OH_45J6 OTP_125FP<br>10 12<br>4516 ¯4,5 16<br>¯66 I ON 0 OFF 12<br>35100 OOFF ON I ON II 37 41 60 [90]<br>45<br>140 (3-pole)<br>44 6,5 8 6 193 (4-pole)<br>nero 36 45 6 12 L 56,5 26 11 56 14 56 11 26<br>PT 26,5 [| 26,5<br>OT16…40F_C OT63…80F_C OT100…125F_C<br>Selector handle OH_S2AJE011 Selector handle OH_S2AJE011 Selector handle OH_S2AJE011<br>Shaft OXS6X_ Installation depth [mm] Shaft OXS6X_ Installation depth [mm] Shaft OXS6X_ Installation depth [mm]<br>85 103…114 85 121…131 85 120…130<br>105 123…134 105 141…151 105 140…150<br>120 138…149 120 156…166 120 155…165<br>130 148…159 130 166…176 130 165…175<br>Pistol handle OH_45J6E311 Pistol handle OH_45J6E311 Pistol handle OH_45J6E311<br>Shaft OXS6X_ Installation depth [mm] Shaft OXS6X_ Installation depth [mm] Shaft OXS6X_ Installation depth [mm]<br>150 164…175 150 183…194 150 192…206<br>170 184…195 170 203…214 170 212…226<br>265 279…290 265 298…309 265 307…321<br>400 414…425 400 433…444 400 442…456<br>**----- End of picture text -----**<br> 28 | 1SCC303003C0201 | Transfer, change-over and bypass switches ## Manual change-over switches Dimensional drawings **==> picture [489 x 551] intentionally omitted <==** **----- Start of picture text -----**<br> 159,5<br>A2 150<br>OT160...OT250E03/04C_P 66<br>OT160-250_C_ 32,525 9,0 20 38,5 3 72 259,5 83 6<br>[mm] E03 E04 E12 E13 E22 E23 E33<br>A 35 35 35 35 35 35 35 100 122<br>A1 130<br>A1 116 116 116 116 116 116 116 130 150<br>A2 155 190 155 190 190 225 260<br>B 170 205 170 205 205 240 275 65<br>—aaeeeee °°"4<br>14 min<br>C000001 / OT160-250E02-04_C_ C /ES 60 A 25 63<br>B 240...285<br>(OXP 6 x 161) 45<br>159,5<br>150<br>A2<br>66<br>OT160...OT250E03/04WC_P 32,5 9,0 38,5 3 72 9,5 83<br>25 20<br>OT160-250_WC 25<br>[mm] E03 E04 100 170 6<br>A 43 43 A1<br>A1 116 116 130 122130150<br>A2 179 222<br>65<br>B 194 237<br>68 A 25 14 min<br>C000010 / OT160-250E_WC_ C /ES B 63<br>240...285 45<br>(OXP 6 x161)<br>A2 202,5 81<br>OT315...400E03/04C_P 44,5 11 25 46 4 182 126<br>35,25<br>87 32,5 [20,5] 12<br>OT315-400_C<br>[mm] E03 E04 E12 E13 E22 E23 E33 A1120 150<br>A 44 44 44 44 44 44 44 156 160<br>185<br>A1 142 142 142 142 142 142 142<br>95<br>A2 202,5 246,5 202,5 246,5 246,5 290,5 334,5<br>20 min<br>B 221 265 221 265 265 309 353 83,25 A 31,25 86<br>B 261...325 45<br>C000008 / 315-400E02-04_C_ C /ES (OXP 12 x 166)<br>__<br>**----- End of picture text -----**<br> OT160...OT250E03/04WC_P |OT160-250_WC|OT160-250_WC|| |---|---|---| |**[mm]**|**E03**|**E04**| |A<br>A1|43<br>116|43<br>116| |A2|179|222| |B|194|237| C000010 / OT160-250E_WC_ C /ES Transfer, change-over and bypass switches | 1SCC303003C0201 | 29 ## Manual change-over switches Dimensional drawings **==> picture [487 x 571] intentionally omitted <==** **----- Start of picture text -----**<br> A2 110,5<br>280<br>OT630...800E03/04C_P 256<br>58 5 138,6<br>39 13,5 64,1 132,6<br>47,5<br>OT630-800_C_ 45 61,5<br>[mm] E03 E04 E12 E13 E22 E23 E33<br>12<br>A 65 65 65 65 65 65 65<br>A1 180 180 180 180 180 180 180 200 ON 198<br>A1 210 160<br>A2 290 355 290 355 355 420 485 OFF ON 250<br>B 311 376 311 376 376 441 506<br>125<br>M00088/OT630-800E02-04C_ C /ES<br>25<br>112,5 A |__| 47,5 118,5<br>B 324...422 45<br>(OXP 12x185)<br>335<br>309<br>295<br>OT1000...1600E03/04CP A2 158,5 167<br>8065 50 13,5 74,515 136 OT1000-125050 13,5 OT1600<br>OT1000-1600_C_ 372 83 83<br>54<br>_———————————— [mm] E03 E04 E12 E13 E22 338 12 400<br>A 80 80 80 80 80 260 326 206 306<br>A1 258 372<br>A1 230 230 230 230 230 246<br>71<br>A2 370 450 370 450 450 14 80 11 6<br>B 400 480 400 480 480 106 20 min 22,5 40<br>147 A 63 358...444 20<br>M00155/OT1000-1600E_C-1 E /ES B (OXP 12x185)<br>335<br>309<br>295<br>OT2000…2500E03/04CP A2 158,5 167<br>80<br>OT2000-2500_C_ 65 100 Ø 13,5 15 1 36<br>74,5<br>[mm] E03 E04 E12 E13 E22 85<br>A 126 126 126 126 126 54<br>12<br>A1 230 230 230 230 230 400<br>A2 508 634 508 634 634 260A1 OFF o ONON 206<br>B 538 664 538 664 664<br>71<br>M00179/ OT2000-2500E_C_ D /ES 14 80<br>20 min<br>106<br>170 A 86 358...444<br>B ( OXP 12X185 )<br>250,5 262,5330,5 342,5 376,5<br>**----- End of picture text -----**<br> 30 | 1SCC303003C0201 | Transfer, change-over and bypass switches ## Manual change-over switches Dimensional drawings **==> picture [492 x 399] intentionally omitted <==** **----- Start of picture text -----**<br> 429<br>A 245<br>OT3200E02/03/04C_P<br>141<br>200<br>223<br>OT3200_C 100 o 13,5 63 191 15<br>156,5<br>[mm] E02 E03 E04 70<br>A 420 SS 560 700 : s | s| li le l e lil e ei m ien<br>B 450 590 730 280 284 364 410 12 400<br>M00435/OT3200E02-04C B 250 296 376 240<br>20 min<br>106 max<br>100,5<br>170,5<br>112<br>15<br>140 325 71<br>B 369...455 80<br>(OXP 12x185)<br>429<br>A 245<br>OT3200E12/13/22C_P p iSSier tes a | IE 141<br>OT3200E_C C 1 00 O 13,5 223 63 1 91 15<br>156,5<br>[mm] E12 E13 E22<br>A 560 700 700<br>B 590 730 730 280<br>C 210 210 350 250 284 364 410 240 12 400<br>376<br>296<br>M00436/OT3200E12-22C B 20 min<br>106 max<br>100,5<br>170,5<br>15<br>140 325 71<br>369...455 80<br>B (OXP 12X185)<br>**----- End of picture text -----**<br> Transfer, change-over and bypass switches | 1SCC303003C0201 | 31 ## Manual change-over switches Dimensional drawings for UL/CSA -types **==> picture [485 x 638] intentionally omitted <==** **----- Start of picture text -----**<br> OT30...100_C OH_45J6 11 75 55 EN 500223,3 OA1G01 63 ¿4,5 22,5 22,5 OTS125T3OA1G10 OTP_125FPOTS125T1<br>10<br>45<br>Selector handle OH_S2AJE011 16 ¯4,5<br>0 OFF<br> I<br>Shaft OXS6X_ 85 Installation depth [mm] 120…130 ¯66 35100 OOFF ON ONI ON II 37 41 60 [90]<br>105 140…150 45<br>120 155…165 44 6,5 8 6<br>130 165…175 36 45 6 12 L 56,5 26 11 56 14 56 11 26<br>26,5 26,5<br>Pistol handle OH_45J6E311 12<br>16<br>Shaft OXS6X_ Installation depth [mm] 12<br>150 192…206<br>170 212…226<br>265 307…321<br>400 442…456 140 (3-pole)<br>193 (4-pole)<br>159,5<br>6,28<br>150<br>A2 5,91 66/2,6<br>72<br>OT200U03/04CP 32,51,280,9825 9,00,35 020,79 38,51,52 0,123 2,83 0,379,5 3,27/1,4083/35,5<br>25<br>0,98<br>OT200_C_ 6<br>0,24<br>[mm/in] — U03 U04 3,94100 "7 olslos 5,91150 a 6,69170 l | al l<br>A 43/1,69 43/1,69 A1 130<br>A1 116/4,57 116/4,57 5,12130 1225,12<br>A2 179/7,05 222/8,74 4,80<br>65<br>B 194/7,64 237/9,33 2,56<br>C000002 / OT200U02_04_C _ C /ES 68 A 25 14 min<br>2,68 B 0,98 0,55<br>63<br>240...285 2,48 45<br>9,45...11,22 1,77<br>(OXP 6 x161)<br>202,5<br>182 7,97<br>A2 7,17 81 / 3,19<br>OT400U03/04CP 44,51,75 110,43 25 1,8146 40,16 3,4387 20,50,81 126 / 51,5<br>35,25 0,98 4,96 / 2,03<br>1,39<br>32,5<br>OT400_C_ 1,28 12<br>_ a olislice pan I) 0,47<br>[mm/in] U03 U04 150<br>156 5,91<br>A 54/2,13 54/2,13 6,14 A1 160<br>A1 142/5,59 142/5,59 4,72120 6,30 2208,66<br>A2 232,5/9,15 286,5/11,28 7,28185<br>B 251/9,88 305/12,01 3,7495<br>C000009 / OT400U02-04_C_ C /ES<br>20 min<br>93,25 A 31,25 86 0,79<br>3,67 B 1,23 3,39<br>261...325 45<br>10,28...12,80 1,77<br>(OXP 12 x 166)<br>**----- End of picture text -----**<br> 32 | 1SCC303003C0201 | Transfer, change-over and bypass switches ## Manual change-over switches Dimensional drawings for UL/CSA -types **==> picture [489 x 424] intentionally omitted <==** **----- Start of picture text -----**<br> 280<br>A2 11,02 256<br>10,08<br>OT600U03/04CP<br>OT600_C_ 582,28 39 13,5 0,205 132,65,22<br>[mm/in] U03 U04 1,8747,5 1,54 0,53 64,12,52<br>A 65/2,56 65/2,56 1,7745<br>A1 180/7,09 180/7,09 509 12<br>198 20,04 0,47<br>A2 290/11,42 355/13,98 7,87200 ON 7,80 400<br>B 311/12,24 376/14,80 A1 OFF ON 8,27210 250 15,751606,30<br>9,84<br>M00087/OT600U02-04C_ C /ES<br>125<br>4,92<br>112,54,43 A 47,51,87 0,9424 45<br>t B ee 1184,66,5 1,77 l<br>324...422 (OXP 12x185)<br>12,76...16,61<br>335 / 13,2<br>A2 295 / 11,61<br>OT800U03/04CP 13,5 309<br>65 0,53 50 15 136 12,17<br>2,56 1,97 0,59 5,35<br>89 74,5<br>OT800_C_ [mm/in] U03 U04 3,15 14,65372 15,98406 2,93 3,2783 54 3,2783<br>AA1A2 80/3,15230/9,06370/14,56 80/3,15450/17,72230/9,06 10,24260A1 9,6924610,1625812,8332613,31338 21,50546 8,11206 0,4712 2,1371 15,7540014,65372<br>B 400/15,75 480/18,90 2,80<br>14 80<br>0,55 3,15 1,5740 6<br>M00156/OT800-1200U_C-1 C /ES 106 0,79 min20 min 0,24<br>147 A 63 4,17 20<br>5,79 B 2,48 0,79<br>358...444 (OXP 12x185)<br>14,09...17,48<br>**----- End of picture text -----**<br> Transfer, change-over and bypass switches | 1SCC303003C0201 | 33 ## Optional accessories for manual change-over switches Ordering information for handle knobs ## Handle knobs No shaft needed, direct mounting on the top of the switch. OHRS2_ OHRS3_ OHBS9_ OHRS9_ OHBS11 OHBS12 |**Suitable**<br>**for switches**|**Colour**|**Type**|**Order number**|**Units/**<br>**type**<br>**[pcs]**|**Weight/**<br>**unit**<br>**[kg]**| |---|---|---|---|---|---| |**Padlockable in 0-position**|||||| |OT16…80F_C|Black|OHBS2/1|1SCA109090R1001|1|0.01| |OT16…80F_C|Black|OHBS2|1SCA109089R1001|10|0.01| |OT16…80F_C|Red|OHRS2/1|1SCA108599R1001|1|0.01| |OT16…80F_C|Red|OHRS2|1SCA108598R1001|10|0.01| |OT16…80F_C|Black|OHBS12/1|1SCA109094R1001|1|0.01| |OT16…80F_C|Black|OHBS12|1SCA108252R1001|10|0.01| |OT16…80F_C|Red|OHRS12/1|1SCA109097R1001|1|0.01| |OT16…80F_C|Red|OHRS12|1SCA108253R1001|10|0.01| |OT100...125F_C|Black|OHBS11/1|1SCA109093R1001|1|0.02| |OT100...125F_C|Black|OHBS11|1SCA109092R1001|10|0.02| |**Non-padlockable**|||||| |OT16…80F_C|Black|OHBS3/1|1SCA108319R1001|1|0.01| |OT16…80F_C|Black|OHBS3|1SCA108320R1001|10|0.01| |OT16…80F_C|Red|OHRS3/1|1SCA108688R1001|1|0.01| |OT16…80F_C|Red|OHRS3|1SCA108667R1001|10|0.01| |OT100...125F_C|Black|OHBS9/1|1SCA108689R1001|1|0.01| |OT100...125F_C|Black|OHBS9|1SCA108665R1001|10|0.01| |OT100...125F_C|Red|OHRS9/1|1SCA108690R1001|1|0.01| |OT100...125F_C|Red|OHRS9|1SCA108666R1001|10|0.01| 34 | 1SCC303003C0201 | Transfer, change-over and bypass switches ## Optional accessories for manual change-over switches Ordering information for external handles ## Selector handle, indication I-O-II IP65, Nema type 1, 3R, 12. Padlockable in O -position with maximum three padlocks with bail diameter 5...8 mm (two lower holes) and 5...6.3 mm (the upper hole). Door interlock in I- and II-position and when padlocked in O-position. OHBS2_ OHB45J6_ OHB65J6_ OHY125J12_ |**Suitable**<br>**for**<br>**switches**|**Colour**|**Shaft**<br>**diameter**<br>**[mm]**||**Type**|**Order number**|**Delivery**<br>**batch**<br>**[pcs]**|**Weight/**<br>**unit**<br>**[kg]**| |---|---|---|---|---|---|---|---| |OT16...125F_C|Black|6||OHBS2AJE011|1SCA105220R1001|1|0.07| |OT16...125F_C|Red-yellow|6||OHYS2AJE011|1SCA105301R1001|1|0.07| |Pistol handle, plastic,indication I-O-II|||indication I-O-II||||| |**Suitable**<br>**for**<br>**switches**|**Colour**|**Shaft**<br>**diameter**<br>**[mm]**||**Type**|**Order number**|**Delivery**<br>**batch**<br>**[pcs]**|**Weight/**<br>**unit**<br>**[kg]**| |**Padlockable in all positions**|||||||| |IP65, Nema type 1, 3R, 12. Door interlock in I- and II-position and when padlocked.<br>Padlocking possibility with three padlocks, bail dia Ø 5...10 mm.|||||IP65, Nema type 1, 3R, 12. Door interlock in I- and II-position and when padlocked.||| |OT16...125F_C|Black|6||OHB45J6E311|1SCA022817R2130|1|0.10| |OT16...125F_C|Red-yellow|6||OHY45J6E311|1SCA022817R2300|1|0.10| |OT160…250_C|Black|6||OHB65J6E311|1SCA022662R4730|1|0.12| |OT315…400_C|Black|12||OHB95J12E311|1SCA022779R2140|1|0.12| |OT630…800_C|Black|12||OHB125J12E311|1SCA022615R1730|1|0.14| |OT1000…3200_C|Black|12||OHB200J12PE311|1SCA104685R1001|1|0.40| **Padlockable in the O-position** IP65, Nema type 1, 3R, 12. Door interlock in I- and II-position and when padlocked. Padlocking possibility with three padlocks, bail dia Ø 5...10 mm. OHB274J12_ OHB200J12P_ OHB65J6E69 |OT16…125F_C|Black|6|OHB45J6E011|1SCA022594R7110|1|0.10| |---|---|---|---|---|---|---| |OT16…125F_C|Red-yellow|6|OHY45J6E011|1SCA022817R2210|1|0.10| |OT160…250_C|Black|6|OHB65J6E011|1SCA022383R2480|1|0.12| |OT160…250_C|Red-yellow|6|OHY65J6E011|1SCA022779R1840|1|0.12| |OT315…400_C|Black|12|OHB95J12E011|1SCA022621R0760|1|0.12| |OT315…400_C|Red-yellow|12|OHY95J12E011|1SCA022621R0920|1|0.12| |OT630…800_C|Black|12|OHB125J12E011|1SCA022589R3340|1|0.14| |OT630…800_C|Red-yellow|12|OHY125J12E011|1SCA022615R1650|1|0.14| |OT1000…3200_C|Black|12|OHB274J12E011|1SCA122306R1001|1|0.54| |OT1000…3200_C|Black|12|OHB200J12PE011|1SCA022873R4230|1|0.40| |OT1000…3200_C|Red-yellow|12|OHY200J12PE011|1SCA104686R1001|1|0.40| Transfer, change-over and bypass switches | 1SCC303003C0201 | 35 ## Optional accessories for manual change-over switches Ordering information for external handles Pistol handle for closed transition types, plastic, indication I - I+II - II IP65, operating angle 90°. OHB65J6E65 OHB95J12E65 |**Suitable**<br>**for**<br>**switches**|**Colour**|**Shaft**<br>**diameter**<br>**[mm]**||**Type**|**Order number**|**Delivery**<br>**batch**<br>**[pcs]**|**Weight/**<br>**unit**<br>**[kg]**| |---|---|---|---|---|---|---|---| |**Handle not padlockable and no door interlocking**|||||||| |OT160...250_CL|Black|6||OHB65J6E65|1SCA112050R1001|1|0.12| |OT315...400_CL|Black|12||OHB95J12E65|1SCA112056R1001|1|0.12| |OT630...800_CL|Black|12||OHB145J12E65|1SCA112063R1001|1|0.14| |OT1000...2500_CL|Black|12||OHB200J12PE65|1SCA112078R1001|1|0.40| Plastic handle, direct mounting, indication I-O-II Includes a shaft and a mechanism cover. The type and ordering numbers are for one piece. OTV250ECK **==> picture [46 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> OTV1000ECK<br>**----- End of picture text -----**<br> |**Suitable**<br>**for**<br>**switches**<br>**Colour**|**Type**|**Order number**|**Delivery**<br>**batch**<br>**[pcs]**|**Weight/**<br>**unit**<br>**[kg]**| |---|---|---|---|---| |**Padlockable with three padlocks in 0-position.**<br>OT160…250_C<br>Black<br>OT315…400_C<br>Black<br>OT630…800_C<br>Black<br>OT1000…2500_C<br>Black|OTV250ECK<br>OTV400ECK<br>OTV800ECK<br>OTV1000ECK|1SCA022783R0090<br>1SCA022783R0170<br>1SCA022797R2470<br>1SCA107481R1001|1<br>1<br>1<br>1|0.08<br>0.26<br>0.30<br>0.75| |Includes a shaft (no mechanism cover)||||| |OTM40...125F_C<br>Black<br>OHB65D6CM<br>1SCA022807R9430<br>1<br>0.12<br>**Handle not padlockable, operating angle 90°.**<br>OT160…250_CF<br>Black<br>OTV250ECFK<br>1SCA113141R1001<br>1<br>0.08<br>OT315…400_CF<br>Black<br>OTV400ECFK<br>1SCA113147R1001<br>1<br>0.26<br>OT630…800_CF<br>Black<br>OTV800ECFK<br>1SCA113151R1001<br>1<br>0.30<br>~~——o~~||||| OTV1000ECLK Plastic handle for closed transition types, direct mounting, indication I - I+II - II Includes a shaft and a mechanism cover. The type and ordering numbers are for one piece. |**Suitable**<br>**for**<br>**switches**|**Colour**|**Type**|**Order number**|**Delivery**<br>**batch**<br>**[pcs]**|**Weight/**<br>**unit**<br>**[kg]**| |---|---|---|---|---|---| |**Handle not padlockable, operating angle 90°.**|||||| |OT160…250_CL|Black|OTV250ECLK|1SCA113137R1001|1|0.08| |OT315…400_CL|Black|OTV400ECLK|1SCA113143R1001|1|0.26| |OT630…800_CL|Black|OTV800ECLK|1SCA113148R1001|1|0.30| |OT1000...2500_CL|Black|OTV1000ECLK|1SCA113152R1001|1|0.75| 36 | 1SCC303003C0201 | Transfer, change-over and bypass switches Optional accessories for manual change-over switches Dimensional drawings for external handles ## Plastic handles **==> picture [527 x 405] intentionally omitted <==** **----- Start of picture text -----**<br> 36 45<br>Handle type Handle length L [mm] Shaft B [mm]<br>66 OH_45J6E_ 45 6<br>OH_65J6E_ 65 6<br>B<br>OH_95J12E_ 95 12<br>OH_125J12E_ 125 12<br>OH_145J12E_ 145 12<br>L OH_175J12E_ 175 12<br>OH_200J12E_ 200 12<br>OH_275J12E_ 275 12<br>80 70 80 71<br>54 54<br>69,4 69,4<br>L L<br>Handle type L [mm] Handle type L [mm]<br>OH_274J12 274 OHB150J12P 300<br>OHB200J12P 400<br>**----- End of picture text -----**<br> Door drilling for OH_ handles **==> picture [527 x 203] intentionally omitted <==** **----- Start of picture text -----**<br> Valid for switches Valid from switches Valid from switches 1000 A<br>up to 125 A from 200 to 800 A and higher (OHB handles)<br>31 5 5 31 31 5<br>ON OFF<br>45°<br>OFF ON ON<br>45°<br>ON<br>53 53 53<br>45°<br>**----- End of picture text -----**<br> Transfer, change-over and bypass switches | 1SCC303003C0201 | 37 Optional accessories for manual change-over switches Ordering information for extended shafts |Shafts for selector handle handles<br>**For switches**<br>**Length[mm]**<br>**Type**<br>**Order number**<br>**Delivery batch[pcs]**<br>**Weight/unit[kg]**<br>**Shaft diameter 6 mm**<br>OT16...125F_C<br>85<br>OXS6X85<br>1SCA101647R1001<br>10<br>0.03<br>105<br>OXS6X105<br>1SCA108043R1001<br>10<br>0.03<br>OXS6X_<br>~~NO~~|Shafts for selector handle handles<br>**For switches**<br>**Length[mm]**<br>**Type**<br>**Order number**<br>**Delivery batch[pcs]**<br>**Weight/unit[kg]**<br>**Shaft diameter 6 mm**<br>OT16...125F_C<br>85<br>OXS6X85<br>1SCA101647R1001<br>10<br>0.03<br>105<br>OXS6X105<br>1SCA108043R1001<br>10<br>0.03<br>OXS6X_<br>~~NO~~|Shafts for selector handle handles<br>**For switches**<br>**Length[mm]**<br>**Type**<br>**Order number**<br>**Delivery batch[pcs]**<br>**Weight/unit[kg]**<br>**Shaft diameter 6 mm**<br>OT16...125F_C<br>85<br>OXS6X85<br>1SCA101647R1001<br>10<br>0.03<br>105<br>OXS6X105<br>1SCA108043R1001<br>10<br>0.03<br>OXS6X_<br>~~NO~~|Shafts for selector handle handles<br>**For switches**<br>**Length[mm]**<br>**Type**<br>**Order number**<br>**Delivery batch[pcs]**<br>**Weight/unit[kg]**<br>**Shaft diameter 6 mm**<br>OT16...125F_C<br>85<br>OXS6X85<br>1SCA101647R1001<br>10<br>0.03<br>105<br>OXS6X105<br>1SCA108043R1001<br>10<br>0.03<br>OXS6X_<br>~~NO~~|Shafts for selector handle handles<br>**For switches**<br>**Length[mm]**<br>**Type**<br>**Order number**<br>**Delivery batch[pcs]**<br>**Weight/unit[kg]**<br>**Shaft diameter 6 mm**<br>OT16...125F_C<br>85<br>OXS6X85<br>1SCA101647R1001<br>10<br>0.03<br>105<br>OXS6X105<br>1SCA108043R1001<br>10<br>0.03<br>OXS6X_<br>~~NO~~|Shafts for selector handle handles<br>**For switches**<br>**Length[mm]**<br>**Type**<br>**Order number**<br>**Delivery batch[pcs]**<br>**Weight/unit[kg]**<br>**Shaft diameter 6 mm**<br>OT16...125F_C<br>85<br>OXS6X85<br>1SCA101647R1001<br>10<br>0.03<br>105<br>OXS6X105<br>1SCA108043R1001<br>10<br>0.03<br>OXS6X_<br>~~NO~~|Shafts for selector handle handles<br>**For switches**<br>**Length[mm]**<br>**Type**<br>**Order number**<br>**Delivery batch[pcs]**<br>**Weight/unit[kg]**<br>**Shaft diameter 6 mm**<br>OT16...125F_C<br>85<br>OXS6X85<br>1SCA101647R1001<br>10<br>0.03<br>105<br>OXS6X105<br>1SCA108043R1001<br>10<br>0.03<br>OXS6X_<br>~~NO~~|Shafts for selector handle handles<br>**For switches**<br>**Length[mm]**<br>**Type**<br>**Order number**<br>**Delivery batch[pcs]**<br>**Weight/unit[kg]**<br>**Shaft diameter 6 mm**<br>OT16...125F_C<br>85<br>OXS6X85<br>1SCA101647R1001<br>10<br>0.03<br>105<br>OXS6X105<br>1SCA108043R1001<br>10<br>0.03<br>OXS6X_<br>~~NO~~| |---|---|---|---|---|---|---|---| |120<br>OXS6X120<br>1SCA101654R1001<br>10<br>0.04<br>130<br>OXS6X130<br>1SCA101655R1001<br>10<br>0.04<br>Shafts forpistol handles<br>**For switches**<br>**Length[mm]**<br>**Type**<br>**Order number**<br>**Delivery batch[pcs]**<br>**Weight/unit[kg]**<br>OXS6X_<br>~~a~~|||||||| |OXP6X_|**Shaft diameter 6 mm**||||||| |OXP6X_|OT16…125F_C||150|OXP6X150|1SCA022295R5600|10|0.05| ||||170|OXP6X170|1SCA108224R1001|10|0.05| ||||265|OXP6X265|1SCA108225R1001|10|0.08| ||||400|OXP6X400|1SCA108226R1001|10|0.12| ||**Shaft diameter 6 mm**||||||| ||OT160...250_C||90|OXP6X90|1SCA022064R1180|10|0.03| ||||130|OXP6X130|1SCA022057R0570|10|0.04| ||||161|OXP6X161|1SCA022067R1760|10|0.05| ||||210|OXP6X210|1SCA022295R6080|10|0.06| ||||290|OXP6X290|1SCA022042R6370|10|0.08| ||||360|OXP6X360|1SCA022042R6530|10|0.11| ||**Shaft diameter 6/12 mm (6 mm to 12 mm conversion shaft)**|||**Shaft diameter 6/12 mm (6 mm to 12 mm conversion shaft)**|||| ||OT160...250E||161|OXP6/12x161C|1SCA111724R1001|1|0.05| ||**Shaft diameter 12 mm**||||||| ||OT315...400_C||107|OXP12X107|1SCA022029R9750|1|0.12| ||||148|OXP12X148|1SCA022658R5570|1|0.17| |OXP12X|||166|OXP12X166|1SCA022325R7100|1|0.20| |OXP12X|||185|OXP12X185|1SCA022325R6710|1|0.22| ||||250|OXP12X250|1SCA022325R6980|1|0.29| ||||280|OXP12X280|1SCA022137R5140|1|0.33| ||||325|OXP12X325|1SCA022042R5810|1|0.38| ||||395|OXP12X395|1SCA022042R5990|1|0.46| ||||465|OXP12X465|1SCA022042R6020|1|0.54| ||OT630…800_C||148|OXP12X148|1SCA022658R5570|1|0.17| ||||185|OXP12X185|1SCA022325R6710|1|0.22| ||||250|OXP12X250|1SCA022325R6980|1|0.29| ||||325|OXP12X325|1SCA022042R5810|1|0.38| ||||395|OXP12X395|1SCA022042R5990|1|0.46| ||||465|OXP12X465|1SCA022042R6020|1|0.54| ||OT1000…3200||166|OXP12X166|1SCA022325R7100|1|0.20| ||||185|OXP12X185|1SCA022325R6710|1|0.23| ||||250|OXP12X250|1SCA022325R6980|1|0.29| ||||325|OXP12X325|1SCA022042R5810|1|0.38| ||||395|OXP12X395|1SCA022042R5990|1|0.46| ||||465|OXP12X465|1SCA022042R6020|1|0.54| OXS6X_ OXP6X_ OXP12X 38 | 1SCC303003C0201 | Transfer, change-over and bypass switches ## Optional accessories for manual change-over switches Ordering information for terminal shrouds ## Terminal shrouds, transparent plastic Snap-on mounting to the switches, IP20. The full shrouding of a 3-pole change-over switch is achieved with four 3-pole shrouds. OTS_T3 OTS_T1 |**Suitable**<br>**for**<br>**switches**|**Type**|**Order number**|**Delivery**<br>**batch**<br>**[pcs]**|**Weight/**<br>**unit**<br>**[kg]**| |---|---|---|---|---| |**For three pole switches**||||| |OT16…40F_C|OTS40T3|1SCA105317R1001|10|0.01| |OT63…80F_C|OTS63T3|1SCA022353R6750|10|0.01| |OT100...125F_C|OTS125T3|1SCA022379R9680|10|0.01| |**For fourth pole**||||| |OTPS40FPN1|OTS40T1|1SCA105314R1001|10|0.01| |OTPS40FPN2|OTS40T1|1SCA105314R1001|10|0.01| |OTPS80FP|OTS63T1|1SCA022353R6910|10|0.01| |OTPS60FP, OTPS125FP|OTS125T1|1SCA022379R9760|10|0.01| ## Terminal shrouds, grey plastic Snap-on mounting to the switches, IP 20. A kit includes three or four shrouds which can be used on either side of the switch. Suitable for the upperswitch. Transparent shrouds for OT_160…2500 available on request, please replace the letter “G” with “T”. OTS_L_ OTS_S_ |**Suitable**<br>**for**<br>**switches**|**No.**<br>**of**<br>**poles**|**Description**|**Type**|**Order number**|**Units/**<br>**type**<br>**[pcs]**|**Weight/**<br>**unit**<br>**[kg]**| |---|---|---|---|---|---|---| |OT_160…250_C|3|Long type|OTS250G1L/3|1SCA022731R8150|3|0.09| |OT_160…250_C|3|Short type|OTS250G1S/3|1SCA022731R8310|3|0.06| |OT_160…250_C|4|Long type|OTS250G1L/4|1SCA022731R8230|4|0.12| |OT_160…250_C|4|Short type|OTS250G1S/4|1SCA022731R8400|4|0.08| |OT_315…400_C|3|Long type|OTS400G1L/3|1SCA022736R8840|3|0.15| |OT_315…400_C|3|Short type|OTS400G1S/3|1SCA022736R9060|3|0.09| |OT_315…400_C|4|Long type|OTS400G1L/4|1SCA022736R9490|4|0.20| |OT_315…400_C|4|Short type|OTS400G1S/4|1SCA022736R9650|4|0.12| |OT_600…800_C|3|Long type|OTS800G1L/3|1SCA022776R7890|3|0.32| |OT_600…800_C|3|Short type|OTS800G1S/3|1SCA022776R8190|3|0.17| |OT_600…800_C|4|Long type|OTS800G1L/4|1SCA022776R7970|4|0.42| |OT_600…800_C|4|Short type|OTS800G1S/4|1SCA022776R8270|4|0.26| |OT_1000…1600_C|3|Long type|OTS1600G1L/3|1SCA022871R9510|3|0.64| |OT_1000…1600_C|3|Short type|OTS1600G1S/3|1SCA022871R9600|3|0.37| |OT_1000…1600_C|4|Long type|OTS1600G1L/4|1SCA022871R9780|4|0.85| |OT_1000…1600_C|4|Short type|OTS1600G1S/4|1SCA022871R9860|4|0.49| |OT_2000…2500_C|3|Long type|OTS2500G1L/3|1SCA107261R1001|3|0.77| |OT_2000…2500_C|3|Short type|OTS2500G1S/3|1SCA107260R1001|3|0.47| |OT_2000…2500_C|4|Long type|OTS2500G1L/4|1SCA107262R1001|4|1.00| |OT_2000…2500_C|4|Short type|OTS2500G1S/4|1SCA107271R1001|4|0.61| |OT3200_C|3|Long type|OTS4000G1L/3|1SCA129042R1001|3|1.20| |OT3200_C|3|Short type|OTS4000G1S/3|1SCA129044R1001|3|1.00| |OT3200_C|4|Long type|OTS4000G1L/4|1SCA129043R1001|4|1.40| |OT3200_C|4|Short type|OTS4000G1S/4|1SCA129045R1001|4|1.60| Transfer, change-over and bypass switches | 1SCC303003C0201 | 39 ## Optional accessories for manual change-over switches Ordering information for phase barriers ## Phase barriers The phase barriers designed for ABB Tmax T4-T5 MCCB’s can also be used for OT_160...800 change-over switches. 3-pole change-overs need 8 barriers and 4-pole change-overs need 12 barriers for full protection. OTB_ PB_ |**Suitable**<br>**for**<br>**switches**|**No.**<br>**of**<br>**poles**|**Height**<br>**h**<br>**[mm]**|**Cutting**<br>**width W**<br>**of the**<br>**phase**<br>**barrier**<br>**[mm]**|**Type**|**Order number**|**Units/**<br>**type**<br>**[pcs]**| |---|---|---|---|---|---|---| |OT_160…250E_C|3|100|55|PB100 low|1SDA054970R1|4| |OT_160…250E_C|3|200|55|PB200 high|1SDA054972R1|4| |OT_160…250E_C|4|100|55|PB100 low|1SDA054971R1|6| |OT_160…250E_C|4|200|55|PB200 high|1SDA054973R1|6| |OT_315…400E_C|3|100|67|PB100 low|1SDA054970R1|4| |OT_315…400E_C|3|200|67|PB200 high|1SDA054972R1|4| |OT_315…400E_C|4|100|67|PB100 low|1SDA054971R1|6| |OT_315…400E_C|4|200|67|PB200 high|1SDA054973R1|6| |OT_600...800E_C|3|100|90|PB100 low|1SDA054970R1|4| |OT_600...800E_C|3|200|90|PB200 high|1SDA054972R1|4| |OT_600...800E_C|4|100|90|PB100 low|1SDA054971R1|6| |OT_600...800E_C|4|200|90|PB200 high|1SDA054973R1|6| OZXA38 ## Parallel connection kits Finger protected connection bars for parallel connection of the upper or lower terminals. The bars accept additional cables, the maximum size is stated below. OZXA39 OZXA32 |**Suitable**<br>**for**<br>**switches**|**Cable cross**<br>**section**<br>**[mm2]**|**Type**|**Order number**|**Units/**<br>**type**<br>**[pcs]**|**Weight/**<br>**unit**<br>**[kg]**| |---|---|---|---|---|---| |OT16…40F3C|6 (fine stranded), 10 (stranded)|OZXA33|1SCA022685R0310|1|0.02| |OT16…40F4C|6 (fine stranded), 10 (stranded)|OZXA32|1SCA022683R4110|1|0.03| |OT63…80F3C|25|OZXA38|1SCA022785R2140|1|0.06| |OT63…80F4C|25|OZXA39|1SCA022790R3820|1|0.09| |OT100…125F3C|50|OZXA40|1SCA022790R3910|1|0.16| |OT100…125F4C|50|OZXA41|1SCA022790R4040|1|0.24| |OTM40F3C_|2.5...25/2x2.5...16|OMZC003|1SCA121324R1001|1|0.5| |OTM40F4C_|2.5...25/2x2.5...16|OMZC004|1SCA121325R1001|1|0.65| |OTM40…125F3C_|10...70|OMZC03|1SCA117037R1001|1|0.5| |OTM40…125F4C_|10...70|OMZC04|1SCA117038R1001|1|0.65| OZXA33 40 | 1SCC303003C0201 | Transfer, change-over and bypass switches ## Optional accessories for manual change-over switches Ordering information for terminal clamps Terminal clamp sets for Al- and Cu-cables insulated versions OZXT1 OZXT2...3 OZXB2L OZXB7L OZXB9 |**Suitable**<br>**for**<br>**switches**|**Cable cross**<br>**section**<br>**[mm2]**|**Suitable**<br>**shroud**|**Type **|**Order number**|**Units/**<br>**type**<br>**[pcs]**|**Delivery**<br>**batch**<br>**[pcs]**|**Weight/**<br>**unit**<br>**[kg]**| |---|---|---|---|---|---|---|---| |OT100…125F_|10...70||OZXL1|1SCA022439R6770|3|1|0.14| |OT_160...250E_C|10...70|OTS250_L|OZXB1L|1SCA022169R2030|3|1|0.15| |OT_160...250E_C|10...70|OTS250_L|OZXB1L/1|1SCA022194R0030|1|50|0.05| |OT_160...250E_C|25...120|OZXB2K|OZXB2|1SCA022119R7610|3|1|0.34| |OT_160...250E_C|25...120|OZXB2K|OZXB2/1|1SCA022194R0200|1|50|0.12| |OT_160...250E_C|25...120|OZXB2K|OZXB2L|1SCA022158R7750|3|1|0.43| |OT_160...250E_C|25...120|OZXB2K|OZXB2L/1|1SCA022194R0460|1|50|0.15| |OT_160...250E_C|95...185|OTS250_L|OZXB8|1SCA022744R1510|3|1|0.50| |OT_160...250E_C|95...185|OTS250_L|OZXB8/1|1SCA022744R1600|1|20|0.15| |OT_160...250E_C|95...240|OTS250_L|OZXB9|1SCA022750R3210|3|1|0.50| |OT_160...250E_C|95...240|OTS250_L|OZXB9/1|1SCA022750R3300|1|20|0.15| |OT_315...400E_C|25...120|OZXB2K|OZXB2L|1SCA022158R7750|3|1|0.43| |OT_315...400E_C|25...120|OZXB2K|OZXB2L/1|1SCA022194R0460|1|50|0.15| |OT_315...400E_C|70…185|OZXB3K|OZXB3|1SCA022136R8100|3|1|1.28| |OT_315...400E_C|70…185|OZXB3K|OZXB3/1|1SCA022194R0620|1|20|0.43| |OT_315...400E_C|2x(70…185) OZXB3K|2x(70…185) OZXB3K|OZXB4|1SCA022137R4760|3|1|1.71| |OT_315...400E_C|2x(70…185) OZXB3K|2x(70…185) OZXB3K|OZXB4/1|1SCA022194R0890|1|20|0.57| |OT_315...400E_C|120...240|OZXB5K|OZXB7|1SCA022185R0040|3|1|1.00| |OT_315...400E_C|120...240|OZXB5K|OZXB7/1|1SCA022194R1430|1|20|0.34| |OT_315...400E_C|120...240|OZXB5K|OZXB7L|1SCA022185R7130|3|1|1.17| |OT_315...400E_C|120...240|OZXB5K|OZXB7L/1|1SCA022194R1600|1|20|0.40| |OT_315...400E_C|95...185|OTS400_L|OZXB8|1SCA022744R1510|3|1|0.50| |OT_315...400E_C|95...185|OTS400_L|OZXB8/1|1SCA022744R1600|1|20|0.15| |OT_315...400E_C|95...240|OTS400_L|OZXB9|1SCA022750R3210|3|1|0.50| |OT_315...400E_C|95...240|OTS400_L|OZXB9/1|1SCA022750R3300|1|20|0.15| Transfer, change-over and bypass switches | 1SCC303003C0201 | 41 ## Optional accessories for manual change-over switches Ordering information for bridging- and reversing bars ## Bridging bars The bridging bars provide a connection link either on the incoming or outcoming side of the switch. OTZC13...34 OTZC43...44 OTZC53...54 |**Suitable**<br>**for**<br>**switches**|**No.**<br>**of**<br>**poles**|**Type**|**Order number**|**Units/**<br>**type**<br>**[pcs]**|**Weight/**<br>**unit**<br>**[kg]**| |---|---|---|---|---|---| |OT_160…250_C|3|OTZC13|1SCA022767R6910|3|0.6| |OT_160…250_C|4|OTZC14|1SCA022767R7040|4|0.8| |OT_315…400_C|3|OTZC23|1SCA022767R7120|3|0.6| |OT_315…400_C|4|OTZC24|1SCA022767R7210|4|0.8| |OT_600_C…800E_C|3|OTZC33|1SCA022785R7020|3|1.0| |OT_600_C…800E_C|4|OTZC34|1SCA022785R7110|4|1.3| |OT_1000…1250E_C|3|OTZC43|1SCA022868R0710|3|4.2| |OT_1000…1250E_C|4|OTZC44|1SCA022868R0800|4|5.6| |OT800U_, OT_1600E_C|3|OTZC53|1SCA022868R0980|3|5.6| |OT800U_, OT_1600E_C|4|OTZC54|1SCA022868R1010|4|7.4| |OT_2000…2500E_C|3|OTZC63|1SCA022868R1100|3|10.8| |OT_2000…2500E_C|4|OTZC64|1SCA022868R1360|4|14.5| |OT_3200E_C|3|OTZC73|1SCA128843R1001|3|14.1| |OT_3200E_C|4|OTZC74|1SCA128844R1001|4|18.7| ## Reversing bars A reversing switch can be built by using phase sequence bars in two phases. The kit includes two phase sequence conversion bars. The missing bridging bars must be ordered separately, see above. For example 3-pole switches: one 4-pole standard bridging bar kit is required (one bar for the reversing side, three bars for the other side). OTZR_ |**Suitable**<br>**for**<br>**switches**|**Type**|**Order number**|**Units/**<br>**type**<br>**[pcs]**|**Weight/**<br>**unit**<br>**[kg]**| |---|---|---|---|---| |OT_160…250_C|OTZR1|1SCA100352R1001|2|0.3| |OT_315…400_C|OTZR2|1SCA104647R1001|2|0.3| |OT_600_C…800E_C|OTZR3|1SCA100355R1001|2|0.4| ## Ordering information for fourth poles ## Fourth poles for OT16...125F Snap-on mounting to the left or right side of the switches, IP20. Simultaneous operation with power poles. The type and ordering numbers are for one piece. OTPS40F |**Suitable**<br>**for**<br>**switches**|**Rated current,**<br>**up to 415V**<br>**AC-21A/AC-22A/AC-23A**<br>**I[A]**|**Type**|**Order number**|**Delivery**<br>**batch**<br>**[pcs]**|**Weight/**<br>**unit**<br>**[kg]**| |---|---|---|---|---|---| |OT16…40F_C|40/40/23|OTPS40FPN11)|1SCA105001R1001|10|0.03| |OT16…40F_C|40/40/23|OTPS40FPN22)|1SCA105000R1001|10|0.03| |OT63…80F_C|80/80/75|OTPS80FP|1SCA105461R1001|10|0.06| |OT100...125F_C|125/125/90|OTPS125FP|1SCA105099R1001|10|0.14| 1) Installation to the left side 2) Installation to the right side 42 | 1SCC303003C0201 | Transfer, change-over and bypass switches Optional accessories for manual change-over switches Ordering information and technical data for auxiliary contacts ## Auxiliary contact blocks for OT16...125F Snap-on mounting to the switch, IP 20, max. 2 blocks/ side. Ith = 16 A, suitable for cable cross sections max. 2 x 2,5 mm[2] . Simultaneous action with the main contacts. OA1G01 OA7G10 |**Suitable**<br>**for**<br>**switches**|**Contact**<br>**functions**|**Installation**<br>**side**|**Type**|**Order number**|**Delivery**<br>**batch**<br>**[pcs]**|**Weight/**<br>**unit**<br>**[kg]**| |---|---|---|---|---|---|---| |OT_16...125F_C|1NO|Right|OA1G10|1SCA022353R4970|10|0.03| |OT_16...125F_C|1NC|Right|OA8G01|1SCA022744R2240|10|0.03| |OT_16...125F_C|1NO|Left|OA7G10|1SCA022673R1140|10|0.03| |OT_16...125F_C|1NC|Left|OA1G01|1SCA022353R4890|10|0.03| |OT63...125F3C|1NO+1NC|Either|OA2G111)|1SCA022379R8100|10|0.03| 1) Not mountable on 4-pole change-over switches OA1G10 OA8G01 ## Auxiliary contact blocks for OT160... 3200 Mounting on the right side of the switch: Max. 4 auxiliary contact blocks/switch (totally 8 blocks). Types _AU have gold plated contacts for harsh environments and low operating voltages. Simultaneous action with the main contacts, IP20. |**Suitable**<br>**for**<br>**switches**|**Contact**<br>**functions**|**Installation**<br>**side**|**Type**|**Order number**|**Delivery**<br>**batch**<br>**[pcs]**|**Weight/**<br>**unit**<br>**[kg]**| |---|---|---|---|---|---|---| |OT_160…3200_|1NO|Right|OA1G10|1SCA022353R4970|10|0.03| |OT_160…3200_|1NC|Right|OA3G01|1SCA022456R7410|10|0.03| |OT_160…3200_|1NO|Right|OA1G10AU|1SCA022436R7910|10|0.03| |OT_160…3200_|1NC|Right|OA3G01AU|1SCA022819R5260|10|0.03| OA2G11 ## Auxiliary contacts **Technical data for auxiliary contacts according to IEC 60947-5-1, for OA1G_, OA2G_, OA3G_, OA7G_, OA8G_** |**AC15**|**AC15**|**AC15**|**DC12**|**DC12**|**DC13**|**DC13**| |---|---|---|---|---|---|---| |**Ue/[V]**|**Ie/[A]**|**Ue/[V]**|**Ie/[A]**|**P/[W]**|**Ie/[A]**|**P/[W]**| |230|6|24|10|240|2|50| |400|4|72|4|290|0.8|60| |415|4|125|2|250|0.55|70| |690|2|250|0.55|140|0.27|70| |||440|0.1|44||| ## Function tables |Function tables|Function tables|Function tables|Function tables|Function tables| |---|---|---|---|---| |**Function table of OT160…3200, OT160...800_Y and OTM160…2500 auxiliary contacts / Switch I (max. 2+2)**||||| |**Handleposition**|**Main contacts**||**OA1G10 NO**|**OA3G01 NC**| |I|closed||closed|open| |0|open||open|closed| |II|closed||open|closed| |**Function table of OT160…3200, OT160...800_Y and OTM160…2500 auxiliary contacts / Switch II (max. 2+2)**||||| |**Handleposition**|**Main contacts**||**OA1G10 NO**|**OA3G01 NC**| |I|closed||open|closed| |0|open||open|closed| |II|closed||closed|open| Transfer, change-over and bypass switches | 1SCC303003C0201 | 43 **==> picture [241 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> 44 | 1SCC303003C0201 | Transfer, change-over and bypass switches<br>**----- End of picture text -----**<br> ## Motorized change-over switches Open transition from 40 to 3200 Amperes **==> picture [258 x 394] intentionally omitted <==** **----- Start of picture text -----**<br> Introduction to motorized change-over switches<br>General information 46<br>Product range 47<br>Type codes 48<br>Technical data<br>OTM16...125_C 49<br>OTM160...800_C 50<br>OTM1000...3200 _C 51<br>Motor operator performance data<br>OTM40…125_C 52<br>OTM160… 3200_C 53<br>Ordering information<br>OTM40...OTM125_CMA 54<br>OTM160...OTM3200_CM 56<br>Dimension drawings<br>Motorized change-over switches 62<br>Ordering information for optional accessories<br>Handles and storage clips 66<br>Terminal shrouds 67<br>Phase barriers 68<br>Terminal clamps 68<br>Bridging- and reversing bars 69<br>Voltage sensing connector 70<br>Parallel connection kits 70<br>Auxiliary contacts 71<br>Automatic control units and related accessories 72<br>Dual power sources 75<br>**----- End of picture text -----**<br> ABB‘s motorized change-over switches are suitable for remote operations and ensure a reliable load transfer under any given circumstance. Transfer, change-over and bypass switches | 1SCC303003C0201 | 45 ## Motorized change-over switches Uninterrupted power supply with motorized functionality ABB offers a wide variety of open transition motorized change-over switches from 40 to 3200 Amperes in range. All of our visually redesigned motorized change-over switches now come equipped with a new cover with clear operating instructions and enhanced motor operator performance. ## High performance level Ensuring a high performance level for you is of the utmost importance to us. In change-over applications where the loaded switch may need to be operated remotely, adequate durability has been ensured by testing against the IEC 60947-6-1 standard in the specification of endurance requirements. ## Reduced installation time ABB motorized change-over switches are fast and easy to install. The voltage sensing connectors have been designed to save time, as there is no need to drill holes into the busbars (see page 78 for relevant accessories). Also, the control and power cables are screw mounted, providing a safe and secure connection that stays tight even during transportation. ## Safe and reliable Our switches come equipped with a comprehensive range of inbuilt safety features such as mechanical interlock, which ensures the isolation of the two asynchronous power supplies. This eliminates risk of shortcircuiting between them. The motorized change-over switches are also equipped with a handle for manual operation in case of emergency. ## Space-saving design ABB provides compact and cost-effective components for any and all installations. On average, our motorized change-over switches are 20% smaller than other similar products on the market. 46 | 1SCC303003C0201 | Transfer, change-over and bypass switches Motorized change-over switches Open transition from 40 to 2500 Amperes |**Types**|OTM40F_C|OTM63F_C| |---|---|---| |||OTM80F_C| |||OTM100F_C| |||OTM125F_C| |**lth /A**|**40**<br>**63**<br>**80**<br>**115**<br>**125**|**40**<br>**63**<br>**80**<br>**115**<br>**125**| |le/AC-22A, < 415V|40<br>63<br>80<br>100<br>125|40<br>63<br>80<br>100<br>125| |le/AC-23A, < 415V|40<br>63<br>80<br>80<br>90|40<br>63<br>80<br>80<br>90| |**Types**|OTM160E_C|OTM160E_WC|OTM315E_C|OTM630E_C| |---|---|---|---|---| ||OTM200E_C|OTM200E_WC|OTM400E_C|OTM800E_C| ||OTM250E_C|OTM250E_WC||| |**lth /A**|**160**<br>**200**<br>**250**|**160**<br>**200**<br>**250**|**315**<br>**400**|**630**<br>**800**| |le/AC-22A, < 415V|160<br>200<br>250|160<br>200<br>250|315<br>400|630<br>800| |le/AC-23A, < 415V|160<br>200<br>250|160<br>200<br>250|315<br>400|630<br>800| |le/AC-31B, < 415V|160<br>200<br>250|160<br>200<br>250|315<br>400|650 720| |**Types**|OTM1000E_C|OTM1600E_C|OTM2000E_C| |---|---|---|---| ||OTM1250E_C||OTM2500E_C| ||||OTM3200E_C| |**lth /A**|**1000**<br>**1250**|**1600**|**2000**<br>**2500**<br>**3200**| |le/AC-22A, < 415V|1000<br>1250|1600|| |le/AC-21B, < 415V|||2000<br>2500<br>3200| |le/AC-31B, < 415V|1000<br>1250|1600|| Transfer, change-over and bypass switches | 1SCC303003C0201 | 47 ## Motorized change-over switches Type codes ## Type codes Understanding the type code keys below will help you quickly identify the correct product for your needs. The simple naming system allows you to see the products type, Ampere rating, standard classification and number of poles, all in one glance. ## **Explanation of the types OTM40...125_C** **==> picture [462 x 173] intentionally omitted <==** **----- Start of picture text -----**<br> Option: OTM125 F 3 C M A 230 V<br>Position: 1 2 3 4 5 6 7 8<br>1 Brand and Switch size / Ampere rating<br>2 IEC<br>3 Number of the poles<br>3: 3-poles<br>4: 4-poles<br>4 Change over switch: I-0-II -operation<br>5 Remote control<br>6 Automatic operation available with OMD control unit (controller not included in the delivery)<br>7 Voltage for motor operator<br>230: 110...240 V AC/DC<br>24: 24 V AC/DC<br>8 Motor voltage type<br>V=AC/DC<br>**----- End of picture text -----**<br> **==> picture [462 x 224] intentionally omitted <==** **----- Start of picture text -----**<br> Explanation of the types OTM160...2500_C<br>Option: OTM250 E 3 C M 230 C<br>Position: 1 2 3 4 5 6 7<br>1 Brand and Switch size / Ampere rating<br>2 IEC<br>3 Number of the poles<br>2: 2-poles<br>3: 3-poles<br>4: 4-poles<br>4 Change-over switch: I-0-II -operation<br>5 Motorized change-over switch<br>6 Voltage for motor operator<br>230: 220...240 V AC [1)]<br>110: 110...125 V AC/DC<br>48: 48 V AC/DC<br>24: 24 V AC/DC<br>7 Motor voltage type<br>V: AC/DC<br>C: AC<br>D: DC<br>**----- End of picture text -----**<br> 1) 2-pole versions, motor voltage Ue 220...240V AC/DC 48 | 1SCC303003C0201 | Transfer, change-over and bypass switches ## Motorized change-over switches Technical data for OTM16...125_C Motorized change-over switches **==> picture [525 x 581] intentionally omitted <==** **----- Start of picture text -----**<br> Switch size<br>Data according to IEC 60947-3 OTM40_ OTM63_ OTM80_ OTM100_ OTM125_<br>Rated insulation voltage and rated Pollution V 800 800 800 800 800<br>operational voltage AC20/DC20 degree 3<br>Dielectric strength 50 Hz 1min. kV 6 6 6 6 6<br>Rated impulse withstand voltage kV 8 8 8 8 8<br>Rated thermal current and rated / ambient 40°C In open air A 40 63 80 115 125<br>operational current AC20/DC20 / ambient 40°C In enclosure A 40 63 80 115 125<br>/ ambient 60°C In enclosure A 32 50 63 80 100<br>..with minimum conductor cross section Cu mm [2] 10 16 25 35 50<br>Rated operational current, AC-21A up to 500 V A 40 63 80 100 125<br>690 V A 40 63 80 100 125<br>Rated operational current, AC-22A up to 500 V A 40 63 80 100 125<br> 690 V A 40 63 80 100 125<br>Rated operational current, AC-23A up to 415 V A 40 63 80 80 90<br>500 V A 40 60 60 60 70<br>690 V A 40 40 40 40 50<br>Rated operational current / poles in series, DC-21A up to 48 V A 40/1 63/1 80/1 100/1 125/1<br>110 V A 40/2 63/2 80/2 100/2 125/2<br>220 V A 40/4 63/4 80/4 100/4 100/4<br>Rated operational current / poles in series, DC-22A up to 48 V A 40/1 63/1 80/1 100/1 125/1<br>110 V A 40/2 63/2 80/2 100/2 125/2<br>220 V A 40/4 63/4 80/4 80/4 80/4<br>Rated operational current / poles in series, DC-23A up to 48 V A 40/1 63/1 80/1 100/1 125/1<br>110 V A 40/2 63/2 80/2 100/2 125/2<br>220 V A 40/4 63/4 63/4 63/4 63/4<br>Rated operational power, AC-23A [1)] 230 V kW 7.5 15 22 22 22<br>The kW-ratings are accurate for 3-phase 1500 R.P.M. 400 V kW 18.5 30 37 37 45<br>standard asychronous motors 415 V kW 18.5 30 37 37 45<br>500 V kW 22 37 37 37 45<br>690 V kW 37 37 37 37 45<br>Rated breaking capacity in category AC-23 up to 415 V A 320 504 640 640 720<br>500 V A 320 480 480 480 560<br>690 V A 320 320 320 320 400<br>Rated conditional short-circuit current Iand corresponding max. allowed cut-off current îp (r.m.s.) c Max. OFAIp (r.m.s.) 50 kA, 415 V_ fuse size îgc (peak)G/aM kAA/A 16.5125/125 16.5125/125 125/12516.5 125/12516.5 125/12516.5<br>(peak) value. The cut-off current îlisted by fuse manufacturers (single phase test c refers to values Ip (r.m.s.) 18 kA, 690 V îc (peak) kA 11 11 11 11 11<br>acc. to IEC60269). Max. OFA_ fuse size gG A 125 125 125 125 125<br>Ip (r.m.s.) 50 kA, 690 V îc (peak) kA 10 10 10 10 10<br>Max. OFA_ fuse size gG/aM A/A 63/63 63/63 63/63 63/63 63/63<br>Rated short-time withstand current Icw (r.m.s.) 690 V 1s kA 2.5 2.5 2.5 2.5 2.5<br>Rated short-time making capacity [2)] Icm (peak) 690 V kA 3.6 3.6 3.6 3.6 3.6<br>Power loss / pole With rated current W 1.6 2.8 3.5 4.0 6.3<br>Mechanical endurance Number of oper. cycles [3)] Cycles 10 000 10 000 10 000 10 000 10 000<br>Cable size Cu-wire size suitable for mm [2] 2.5-25/2x2.5-16 10-70 10-70 10-70 10-70<br>terminal clamps AWG 14-4/2x14-6 8-00 8-00 8-00 8-00<br>Terminal tightening torque Counter torque required Nm 6 6 6 6 6<br>Operating torque 3-pole switches Nm 5 5 5 5 5<br>Weight without accessories 3-pole switch kg 1.37 1.37 1.37 1.37 1.37<br>4-pole switch kg 1.60 1.60 1.60 1.60 1.60<br>Data according to IEC 60947-6-1<br>Class of equipment PC PC PC PC PC<br>Rated short-time withstand current Icw (r.m.s.) 690 V 0.1s kA 5 5 5 5 5<br>Conditional short-circuit current Icc (r.m.s.) 415 V kA 50 50 50 50 50<br>Corresponding fuse rating gG/aM fuse 415 V A 125 125 125 125 125<br>Rated operational current, AC-31B up to 415 V A 40 63 80 100 125<br>Rated operational current, AC-32B up to 415 V A 40 63 80 100 125<br>Rated operational current, AC-33B up to 415 V A 40 63 80 80 80<br>**----- End of picture text -----**<br> - 1) These values are given for guidance and may vary according to the motor manufacturer > 2) Short circuit duration > 50ms, without fuse protection - 3) Operating cycle: O - I - O - II - O Transfer, change-over and bypass switches | 1SCC303003C0201 | 49 ## Motorized change-over switches Technical data for OTM160...800_C Motorized change-over switches **==> picture [527 x 527] intentionally omitted <==** **----- Start of picture text -----**<br> Switch size<br>Data according to IEC 60947-3 OT_160_ OT_200_ OT_250_ OT_315_ OT_400_ OT_630_ OT_800_<br>Rated insulation voltage and rated Pollution V 1000 1000 1000 1000 1000 1000 1000<br>operational voltage AC20/DC20 [1)] degree 3 [2)]<br>Dielectric strength 50 Hz 1min. kV 10 10 10 10 10 10 10<br>Rated impulse withstand voltage [3)] kV 12 12 12 12 12 12 12<br>Rated thermal current and rated / ambient 40°C In open air A 160 200 250 315 400 630 800<br>operational current AC20/DC20 / ambient 40°C In enclosure A 160 200 250 315 400 630 800<br>..with minimum conductor Cu mm [2] 70 95 120 185 240 2x185 2x240<br>cross section<br>Rated operational current, AC-21A up to 500 V A 160 200 250 315 400 630 800<br>690 V A 160 200 250 315 400 630 800<br>Rated operational current, AC-22A up to 500 V A 160 200 250 315 400 630 800<br> 690 V A 160 200 250 315 400 630 800<br>Rated operational current, AC-23A up to 415 V A 160 200 250 315 400 630 800<br>440 V A 160 200 250 315 400 630 800<br>500 V A 160 200 250 315 400 630 800<br>690 V A 160 200 250 315 400 630 800<br>Rated operational current / ≤ 110 V A 160/2 200/2 250/2 315/1 [1)] 400/1 [1)] 630/1 800/1<br>poles in series, DC-21A [6)] 220 V A 160/2 200/2 250/2 315/2 [1)] 400/2 [1)] 630/1 800/1<br>440 V A 160/3 200/3 230/3 315/3 360/3 630/2 720/2<br>660 V A 160/4 200/4 200/4 315/4 315/4 630/4 [1)] 630/4 [1)]<br>Rated operational power, AC-23A [2)] 230 V kW 45 60 75 100 132 200 250<br>The kW-ratings are accurate for 400 V kW 90 110 140 160 220 355 450<br>3-phase 1500 R.P.M. standard 415 V kW 90 110 145 180 230 355 450<br>asychronous motors 500 V kW 110 132 170 220 280 400 560<br>690 V kW 160 200 250 315 400 630 800<br>Rated breaking capacity up to 415 V A 1 280 1 600 2 000 2 520 3 200 5 040 6 400<br>in category AC-23 500 V A 1 280 1 600 2 000 2 520 3 200 5 040 6 400<br>690 V A 1 280 1 600 2 000 2 520 3 200 5 040 6 400<br>fuse manufacturers (single phase current îcurrent îRated conditional short-circuit current Ic cp refers to values listed by (r.m.s.) and cut-off (peak) value. The cut-off IMax. OFAMax. OFAIpp (r.m.s.) 80 kA, 415 V (r.m.s.) 100 kA, 500 V__ fuse size fuse size îîggcc (peak) (peak)G/aMG/aM kAkAA/AA 40.540.5355/315315/315 40.540.5315/315355/315 40.540.5315/315355/315 5961.5 500/500500/450 5961.5 500/500500/450 83.590800/1 000800/800 83.590800/1 000800/800<br>test acc. to IEC60269). Ip (r.m.s.) 80 kA, 690 V îc (peak) kA 40.5 40.5 40.5 59 59 83.5 83.5<br>Max. OFA_ fuse size gG/aM A 355/315 355/315 355/315 500/500 500/500 800/1 000 800/1 000<br>Rated short-time withstand current Icw (r.m.s.) 690 V 0.15s kA 15 15 15 31 31 38 38<br>690 V 0.25s kA 15 15 15 24 24 36 36<br>690 V 1s kA 8 8 8 15 15 20 20<br>Rated short-time making capacity [3)] Icm (peak) [4)] 690 V kA 30 30 30 65 65 80 80<br>Power loss / pole With rated current W 2.4 4 6.5 6.5 10 25 40<br>Mechanical endurance Number of oper. cycles [5)] Cycles 8 000 8 000 8 000 8 000 8 000 5 000 5 000<br>Terminal bolt size Metric thread diameter x mm M8x25 M8x25 M8x25 M10x30 M10x30 M12x40 M12x40<br>length<br>Terminal tightening torque Counter torque required Nm 15-22 15-22 15-22 30-44 30-44 50-75 50-75<br>Operating torque 3-pole change-over switches Nm 7 7 7 16 16 27 27<br>Weight without accessories 3-pole switch kg 5.7 5.7 5.7 10.2 10.2 17.5 17.5<br>4-pole switch kg 6.4 6.4 6.4 11.4 11.4 20.4 20.4<br>Data according to IEC 60947-6-1<br>Class of equipment PC PC PC PC PC PC PC<br>Rated short-time withstand current Icw (r.m.s.) 690 V 0.1s kA 15 15 15 25 25 38 38<br>Rated operational current, AC-31B up to 415 V A 160 200 250 315 400 650 720<br>Rated operational current, AC-33B up to 415 V A 160 200 250 315 400 650 650<br>**----- End of picture text -----**<br> - 1) Utilization category B 2) These values are given for guidance and may vary acc. to the motor manufacturer 3) Short circuit duration > 50ms, without fuse protection 4) Max. distance from switch frame to nearest busbar / cable support 150 mm 5) Operating cycle: O - I - O - II - O - 6) Further ratings on request 50 | 1SCC303003C0201 | Transfer, change-over and bypass switches ## Motorized change-over switches Technical data for OTM1000...3200 _C Motorized change-over switches **==> picture [525 x 488] intentionally omitted <==** **----- Start of picture text -----**<br> Switch size<br>Data according to IEC 60947-3 OT_1000_ OT_1250_ OT_1600_ OT_2000_ OT_2500_ OT_3200_<br>Rated insulation voltage and rated Pollution degree 3 [2)] V 1 000 1 000 1 000 1 000 1 000 1 000<br>operational voltage AC20/DC20 [1)]<br>Dielectric strength 50 Hz 1min. kV 10 10 10 10 10 10<br>Rated impulse withstand voltage [3)] kV 12 12 12 12 12 12<br>Rated thermal current and rated / ambient 40°C In open air A 1 000 1 250 1 600 2 000 2 500 3 200<br>operational current AC20/DC20 / ambient 40°C In enclosure A<br>..with minimum conductor Cu mm [2] 2x300 2x400 2x500 3x500 4x500 4x1 000<br>cross section<br>Rated operational current, AC-21A up to 500 V A 1 000 1 250 1 600 2 000 [5)] 2 500 [5)] 3 200 [5)]<br>690 V A 1 000 1 250 1 600<br>Rated operational current, AC-22A up to 500 V A 1 000 1 250 1 600<br> 690 V A 1 000 1 250 1 600<br>Rated operational current, AC-23A up to 415 V A 1 000 1 250 1 250<br>440 V A 1 000 1 250 1 250<br>500 V A 1 000 1 250 1 250<br>690 V A 1 000 1 250 1 250<br>Rated operational power, AC-23A [1)] 230 V kW 315 400 400<br>The kW-ratings are accurate for 400 V kW 560 710 710<br>3-phase 1500 R.P.M. standard 415 V kW 560 710 710<br>asychronous motors 500 V kW 710 900 900<br>690 V kW 1 000 1 200 1 200<br>Rated breaking capacity up to 415 V A 10 000 10 000 10 000<br>in category AC-23 500 V A 10 000 10 000 10 000<br>690 V A 10 000 10 000 10 000<br>current îfuse manufacturers (single phase current îRated conditional short-circuit current Ic cp refers to values listed by (r.m.s.) and cut-off (peak) value. The cut-off Max. OFAIMax. OFAIpp (r.m.s.) 80 kA, 415 V (r.m.s.) 100 kA, 500 V__ fuse size fuse size ggîîcc (peak) (peak)G/aMG/aM kAA/AAkA 1001 250/1 2501061 250/1 250 1001061 250/1 2501 250/1 250 1001061 250/1 2501 250/1 250<br>test acc. to IEC60269). Ip (r.m.s.) 80 kA, 690 V îc (peak) kA<br>Max. OFA_ fuse size gG/aM A<br>Rated short-time withstand current Icw (r.m.s.) 690 V 0.15s kA 50 50 50 50 50<br>690 V 0.25s kA 50 50 50 50 50<br>690 V 1s kA 50 50 50 55 55 65<br>Rated short-time making capacity [2)] Icm (peak) [3)] 690 V kA 92 92 92 110 110 143<br>Power loss / pole With rated current W 19 29 48 55 85 95<br>Mechanical endurance Number of oper. cycles [4)] Cycles 3 000 3 000 3 000 2 000 2 000 2 000<br>Terminal bolt size Metric thread diameter mm M12x60 M12x60 M12x60 M12x60 M12x60 M12x100<br> x length<br>Terminal tightening torque Counter torque required Nm 50-75 50-75 50-75 50-75 50-75 50-75<br>Operating torque 3-pole change-over switches Nm 78 78 78 78 78 80<br>Weight without accessories 3-pole switch kg 42 42 44 56 56 83<br>4-pole switch kg 50 50 52 70 70 101<br>Data according to IEC 60947-6-1<br>Class of equipment PC PC PC<br>Rated short-time withstand current Icw (r.m.s.) 690 V 0.1s kA 50 50 50<br>Rated operational current, AC-31B up to 415 V A 1 000 1 250 1 600<br>Rated operational current, AC-33B up to 415 V A 1 000 1 000 1 000<br>**----- End of picture text -----**<br> - 1) These values are given for guidance and may vary acc. to the motor manufacturer 2) Short circuit duration > 50ms, without fuse protection 3) Max. distance from switch frame to nearest busbar / cable support 150 mm 4) Operating cycle: O - I - O - II - O 5) Category AC-21B, up to 415V Transfer, change-over and bypass switches | 1SCC303003C0201 | 51 ## Motorized change-over switches Motor operator performance data for OTM40…125_C ## Motor operator **==> picture [527 x 505] intentionally omitted <==** **----- Start of picture text -----**<br> Switch size<br>Data according to IEC 60947 40…125<br>Rated operational voltage Ue Pollution degree 3 V AC/DC 110 - 240<br>50/60 Hz V DC 24<br>Operating voltage range 0.85 - 1.1 x U e<br>Operating time [1)] 90° I-0, 0-I, 0-II, II-0 110...240 V AC/DC s 0.5-1.0<br>24 V DC s 0.6-1.3<br>Operating transfer time [1)] 180° I-II, II-I 110...240 V AC/DC s 1.2-1.5<br>24 V DC s 1.4-2.1<br>OFF -time when operating I-II or II-I [1)] 180° I-II, II-I 110...240 V AC/DC s 0.4-0.8<br>24 V DC s 0.6-1.0<br>Nominal current In [1)] 110...240 V AC/DC A 0.2-0.5<br>24 V DC A 0.6<br>Current inrush [1)] 110...240 V AC/DC A 1.5-3.0<br>24 V DC A 3.6<br>Operating rate Cycle 0-I-0-II-0 Max. continuous cycles/min 1<br>Max. short-time ≤ 10 cycles cycles/min 10<br>Overvoltage category III<br>Rated impulse withstand voltage Uimp kV 4<br>Dielectric strength 50 Hz 1 min. kV 1.5<br>Impulse command Min. impulse duration ms 100<br>Terminals<br>Voltage supply wiring for Ue PE - N - L<br>Cross section Solid/stranded mm [2] 1.5 - 2.5<br>Short-circuit protection device Max. MCB A C16<br>Control terminal C - II - I - O<br>Cross section Solid/stranded mm [2] 1.5 - 2.5<br>Maximum cable length m 100<br>Terminal for state information<br>Terminal for state information 1 2 3 4 Solid/stranded mm [2] 1.5<br>Also used with the OMD automatic control unit Rating A 3<br>I II AC-1/250V<br>Common, voltage supply 1<br>Position of switch I 2<br>Position of switch II 3<br>Handle attached or motor operator locked 4<br>Short-circuit protection device Max. MCB A C2<br>Control terminal for OMD automatic control unit<br>Control terminal for OMD automatic control unit Solid/stranded mm [2] 1.5 - 2.5<br>1 2 3<br>Common, voltage supply from motor operator 1 V DC 24<br>Close switch I or open switch II 2 V DC 24<br>mW 500<br>Close switch II or open switch I 3 V DC 24<br>mW 500<br>Operating temperature °C -25…+55<br>Transportation and storage temperature °C -40…+70<br>Max. altitude m 2 000<br>Protection degree (front panel) IP20<br>**----- End of picture text -----**<br> 1) Under nominal conditions 52 | 1SCC303003C0201 | Transfer, change-over and bypass switches ## Motorized change-over switches Motor operator performance data for OTM160…3200_C Motor operator **==> picture [526 x 600] intentionally omitted <==** **----- Start of picture text -----**<br> Switch size<br>Data according to IEC 60947 160…250 315...400 630…800 1000…1600 2000…3200<br>Rated operational voltage Ue Pollution degree 3 50/60 Hz V AC 220 - 240<br>V AC/DC 110 - 125<br>V DC 48<br>V DC 24<br>Operating voltage range 0,85 - 1,1 x Ue<br>Operating time [1)] 90° I-0, 0-I, 0-II, II-0 220-240VAC s 0.4-1.0 0.4-1.0 0.4-1.0 0.5-1.5 0.5-1.5<br>110-125VAC/DC s 0.5-1.5 0.5-1.5 0.6-1.2 0.5-1.5 0.5-1.5<br>48VDC s 0.5-1.5 0.4-1.0 0.6-1.6 0.5-1.5 0.5-1.5<br>24VDC s 0.4-1.0 0.4-1.0 0.5-1.5 1.0-2.0 1.0-2.0<br>Operating transfer time [1)] 180° I-0-II, II-0-I 220-240VAC s 1.0-2.0 0.9-2.0 0.9-2.0 1.5-3.0 1.5-3.0<br>110-125VAC/DC s 1.1-2.5 1.2-2.6 1.2-3.0 1.5-3.0 1.5-3.0<br>48VDC s 1.4-2.5 1.0-2.0 1.3-3.0 1.5-3.0 1.5-3.0<br>24VDC s 1.0-2.0 1.0-2.0 1.1-2.5 2.0-3.5 2.0-3.5<br>OFF -time when operating I-II or II-I [1)] 180° I-II, II-I 220-240VAC s 0.4-1.0 0.4-1.0 0.4-1.0 0.5-1.5 0.5-1.5<br>110-125VAC/DC s 0.4-1.1 0.5-1.5 0.6-1.5 0.5-1.5 0.5-1.5<br>48VDC s 0.5-1.1 0.4-1.0 0.7-1.6 0.5-1.5 0.5-1.5<br>24VDC s 0.4-1.0 0.4-1.0 0.5-1.5 0.8-1.7 0.8-1.7<br>Nominal current In1) 220-240VAC A 0.2 0.5 0.7 1.8 1.8<br>110-125VAC/DC A 0.5 0.6 0.8 3.0 3.0<br>48VDC A 1.1 2.1 2.6 5.3 5.3<br>24VDC A 3.3 4.2 4 8.0 8.0<br>Current inrush [1)] 220-240VAC A 1.3 2.1 2.8 7.7 7.7<br>110-125VAC/DC A 2.1 2.5 4.6 13.3 13.3<br>48VDC A 4.4 8.3 8.4 22.4 22.4<br>24VDC A 16.8 17.5 22.4 26.6 26.6<br>Overload fuse Type / In / Capacity 220-240VAC mA T/315/H T/500/H T/1 000/H T/2 000/H T/2 000/H<br>110-125VAC/DC mA T/500/H T/630/H T/1 000/H T/4 000/H T/4 000/H<br>48VDC A T/1,25/H T/2,5/H T/2,5/H T/5/H T/5/H<br>24VDC A T/4,0/H T/5,0/H T/5,0/H T/10/H T/10/H<br>Size mm 5x20 5x20 5x20 5x20 5x20<br>Operating rate Cycle 0-I-0-II-0, 220-240VAC cycles/min 1 1 1 0.5 0.5<br>max. continuous 110-125VAC/DC cycles/min 1 1 1 0.5 0.5<br>48VDC cycles/min 1 1 1 0.5 0.5<br>24VDC cycles/min 1 1 1 0.5 0.5<br>Max. short-time, 220-240VAC cycles/min 10 10 10 5 5<br>≤ 10 cycles 110-125VAC/DC cycles/min 10 10 10 5 5<br>48VDC cycles/min 10 10 10 5 5<br>24VDC cycles/min 10 10 10 5 5<br>Overvoltage category III<br>Rated impulse withstand voltage Uimp kV 4<br>Dielectric strength 50 Hz 1 min. kV 1.5<br>Impulse command Min. impulse<br>duration ms 100<br>Terminals<br>Voltage supply wiring for U e PE - N - L<br>Cross section solid/stranded mm [2] 1.5 - 2.5<br>Short-circuit protection device max. MCB A C16<br>Control terminal (no SELV) C - II - I - O<br>Cross section solid/stranded mm [2] 1.5 - 2.5<br>Maximum cable length m 100<br>State information of locking (no SELV)<br>Handle attached or motor operator locked 11-12-14 (C/O) 5A/250V/cos ϕ =1<br>Locking motor operator 23-24 (NO) 5A/250V/cos ϕ =1<br>Short-circuit protection device Max. MCB A C2<br>Protection degree IP20<br>Operating temperature °C -25…+55<br>Transportation and storage temperature °C -40…+70<br>Max. altitude m 2 000<br>**----- End of picture text -----**<br> 1) Under nominal conditions Transfer, change-over and bypass switches | 1SCC303003C0201 | 53 Motorized change-over switches Ordering information for OTM40...OTM125_CMA **==> picture [482 x 438] intentionally omitted <==** **----- Start of picture text -----**<br> Installation of accessories – How to?<br>Motorized transfer switches OTM 40…125 A 2 5<br>5<br>re : abe 3<br>1<br>3<br>4<br>4<br>4<br>4<br>3<br>6<br>7<br>**----- End of picture text -----**<br> ## Motorized change-over switch accessory guide 1. Motorized change-over switch 4. Auxiliary contact (Different types for left and right side) 2. Terminal clamp including voltage sensing connector 3. Fourth pole 5. Terminal shroud 6. Handle storage clip 7. Parallel connection kit Please note that not all listed accessories are automatically included in your order. See next page for recommendations. 54 | 1SCC303003C0201 | Transfer, change-over and bypass switches ## Motorized change-over switches Ordering information for OTM40...OTM125_CMA Motorized change-over switches, open transition, OTM40…OTM125_CMA Delivered with a handle for manual operation, a storage clip for the handle and male connectors for control circuit. OTM40...125F3C_ OTM40...125F4C_ |**No.**||**Rated**<br>**current**<br>**AC-21A,**|**Rated**<br>**power**|**Rated**<br>**current**<br>**AC-31B/**|||**Weight/**| |---|---|---|---|---|---|---|---| |**of**||**AC-22A**|**400V**|**AC-33B**|||**unit**| |**poles**||**≤ 415V, I[A]**|**S[kVA]**|**415V, I[A]**|**Type**|**Order number**|**[kg]**| |**Motor voltage U**|**Motor voltage Ue 110...240 V AC/DC**||||||| |3||40|27|40/40|OTM40F3CMA230V|1SCA120096R1001|1.64| |4||40|27|40/40|OTM40F4CMA230V|1SCA120102R1001|1.86| |3||63|43|63/63|OTM63F3CMA230V|1SCA120095R1001|1.64| |4||63|43|63/63|OTM63F4CMA230V|1SCA120101R1001|1.86| |3||80|55|80/80|OTM80F3CMA230V|1SCA120093R1001|1.64| |4||80|55|80/80|OTM80F4CMA230V|1SCA120100R1001|1.86| |3||100|70|100/80|OTM100F3CMA230V|1SCA120071R1001|1.64| |4||100|70|100/80|OTM100F4CMA230V|1SCA120098R1001|1.86| |3||125|86|125/80|OTM125F3CMA230V|1SCA120070R1001|1.64| |4||125|86|125/80|OTM125F4CMA230V|1SCA120097R1001|1.86| |**Motor voltage U**|**Motor voltage Ue 24 V DC**||||||| |3||40|27|40/40|OTM40F3CMA24D|1SCA124061R1001|1.64| |4||40|27|40/40|OTM40F4CMA24D|1SCA124063R1001|1.86| |3||63|43|63/63|OTM63F3CMA24D|1SCA124060R1001|1.64| |4||63|43|63/63|OTM63F4CMA24D|1SCA124064R1001|1.86| |3||80|55|80/80|OTM80F3CMA24D|1SCA124059R1001|1.64| |4||80|55|80/80|OTM80F4CMA24D|1SCA124062R1001|1.86| |3||100|70|100/80|OTM100F3CMA24D|1SCA124058R1001|1.64| |4||100|70|100/80|OTM100F4CMA24D|1SCA124066R1001|1.86| |3||125|86|125/80|OTM125F3CMA24D|1SCA124057R1001|1.64| |4||125|86|125/80|OTM125F4CMA24D|1SCA124065R1001|1.86| ## Handles included as standard, cable cross section |**Suitable for switches**|**Cable cross section [mm2]**|**Handle**| |---|---|---| |OTM40F_CM|2.5...25 or 2 x 2.5...16|OHB65D6CM| |OTM63...125F_CM|10 … 70|OHB65D6CM| ## Recommended accessories: Parallel connection kits and terminal clamp OMZC_ |**Suitable**<br>**for**<br>**switches**|**Cable cross**<br>**section**<br>**[mm2]**|**Type**|**Order number**|**Units/**<br>**type**<br>**[pcs]**|**Weight/**<br>**unit**<br>**[kg]**| |---|---|---|---|---|---| |OTM40F3C_|2.5...25/2x2.5...16|OMZC003|1SCA121324R1001|1|0.5| |OTM40F4C_|2.5...25/2x2.5...16|OMZC004|1SCA121325R1001|1|0.65| |OTM40…125F3C_|10...70|OMZC03|1SCA117037R1001|1|0.5| |OTM40…125F4C_|10...70|OMZC04|1SCA117038R1001|1|0.65| |OTM40...125F_|16...50 Al/2.5...50 Cu|OZXT6|1SCA122537R1001|3|0.06| OZXT6 Transfer, change-over and bypass switches | 1SCC303003C0201 | 55 Motorized change-over switches Ordering information for OTM160...OTM3200_CM ## Installation of accessories – How to? **==> picture [478 x 245] intentionally omitted <==** **----- Start of picture text -----**<br> 2<br>Motorized transfer switches OTM 160…800 A 2<br>_<br>7<br>6<br>5 Dn<br>| }<br>4 —_<br>_<br>1<br>3<br>4<br>**----- End of picture text -----**<br> ## Motorized change-over switch accessory guide 1. Motorized change-over switch 2. Terminal shroud 3. Auxiliary contact 5. Bridging bar 6. Voltage sensing connectors 7. Terminal clamp 4. Storage for handle and fuses Please note that not all listed accessories are automatically included in your order. See next page for recommendations. 56 | 1SCC303003C0201 | Transfer, change-over and bypass switches ## Motorized change-over switches Ordering information for OTM160...OTM400_CM ## Motorized change-over switches, open transition, OTM160…OTM400_CM OTM160...250E2CM230V **==> picture [16 x 14] intentionally omitted <==** **----- Start of picture text -----**<br> M<br>**----- End of picture text -----**<br> Delivered with a handle for manual operation, bolt kit with nut and washers for all terminals and male connectors for control circuits. Types OTM160…400E include a storage clip for the handle and spare fuses. Types OTM160…250E_W are equipped with extended phase distance. 230VAC OTM160...250E2WCM230V OTM160...250E3CM230C OTM160...250E4WCM230C OTM315...400E3CM230V OTM315...400E4CM230C |2|160|110|160/160|OTM160E2CM230V|1SCA121216R1001|5.7| |---|---|---|---|---|---|---| |2|160|110|160/160|OTM160E2WCM230V|1SCA121218R1001|5.9| |3|160|110|160/160|OTM160E3CM230C|1SCA022845R8610|6.6| |3|160|110|160/160|OTM160E3WCM230C|1SCA022846R4000|6.9| |4|160|110|160/160|OTM160E4CM230C|1SCA022848R1510|7.5| |4|160|110|160/160|OTM160E4WCM230C|1SCA022846R7440|7.9| |2|200|135|200/200|OTM200E2CM230V|1SCA121209R1001|5.7| |2|200|135|200/200|OTM200E2WCM230V|1SCA121294R1001|5.9| |3|200|135|200/200|OTM200E3CM230C|1SCA022845R8960|6.6| |3|200|135|200/200|OTM200E3WCM230C|1SCA022846R3960|6.9| |4|200|135|200/200|OTM200E4CM230C|1SCA022846R1590|7.5| |4|200|135|200/200|OTM200E4WCM230C|1SCA022846R7870|7.9| |2|250|170|250/250|OTM250E2CM230V|1SCA121211R1001|5.7| |2|250|170|250/250|OTM250E2WCM230V|1SCA121220R1001|5.9| |3|250|170|250/250|OTM250E3CM230C|1SCA022845R9260|6.6| |3|250|170|250/250|OTM250E3WCM230C|1SCA022846R4770|6.9| |4|250|170|250/250|OTM250E4CM230C|1SCA022846R1910|7.5| |4|250|170|250/250|OTM250E4WCM230C|1SCA022846R8250|7.9| |2|315|215|315/315|OTM315E2CM230V|1SCA121221R1001|9.7| |3|315|215|315/315|OTM315E3CM230C|1SCA022847R1210|11.1| |4|315|215|315/315|OTM315E4CM230C|1SCA022847R2870|12.5| |2|400|275|400/400|OTM400E2CM230V|1SCA121226R1001|9.7| |3|400|275|400/400|OTM400E3CM230C|1SCA022847R1630|11.1| |4|400|275|400/400|OTM400E4CM230C|1SCA022847R3250|12.5| 1) 2-pole versions, motor voltage Ue 220...240V AC/DC ## Handles and bolt kits included as standard |**Suitable for switches**|**Handle**|**Bolt kit**| |---|---|---| |OTM160...250|OTV250ECMK|M8x25| |OTM315...400|OTV400ECMK|M10x30| Recommended accessories: Bridging bars and voltage sensing connectors See pages 69-70 Transfer, change-over and bypass switches | 1SCC303003C0201 | 57 ## Motorized change-over switches Ordering information for OTM630...OTM3200_CM ## Motorized change-over switches, **==> picture [16 x 14] intentionally omitted <==** **----- Start of picture text -----**<br> M<br>**----- End of picture text -----**<br> open transition, OTM630…OTM3200_CM |2|630|435|650/650|OTM630E2CM230V|1SCA121268R1001|19| |---|---|---|---|---|---|---| |3|630|435|650/650|OTM630E3CM230C|1SCA103567R1001|22| |4|630|435|650/650|OTM630E4CM230C|1SCA022873R1990|25| |2|800|550|720/650|OTM800E2CM230V|1SCA121270R1001|19| |3|800|550|720/650|OTM800E3CM230C|1SCA103570R1001|22| |4|800|550|720/650|OTM800E4CM230C|1SCA022872R8340|25| |2|1000|680|1000/1000|OTM1000E2CM230V|1SCA121279R1001|45| |3|1000|680|1000/1000|OTM1000E3CM230C|1SCA112677R1001|55| |4|1000|680|1000/1000|OTM1000E4CM230C|1SCA112703R1001|65| |2|1250|850|1250/1000|OTM1250E2CM230V|1SCA121293R1001|45| |3|1250|850|1250/1000|OTM1250E3CM230C|1SCA112676R1001|55| |4|1250|850|1250/1000|OTM1250E4CM230C|1SCA112702R1001|65| |2|1600|1000|1600/1000|OTM1600E2CM230V|1SCA121280R1001|49| |3|1600|1000|1600/1000|OTM1600E3CM230C|1SCA112678R1001|59| |4|1600|1000|1600/1000|OTM1600E4CM230C|1SCA112704R1001|69| |2|2000|1350||OTM2000E2CM230V|1SCA121289R1001|61| |3|2000|1350||OTM2000E3CM230C|1SCA112709R1001|78| |4|2000|1350||OTM2000E4CM230C|1SCA112712R1001|95| |2|2500|1700||OTM2500E2CM230V|1SCA121291R1001|61| |3|2500|1700||OTM2500E3CM230C|1SCA112710R1001|78| |4|2500|1700||OTM2500E4CM230C|1SCA112713R1001|95| |3|3200|||OTM3200E3CM230C|1SCA129240R1001|83| |4|3200|||OTM3200E4CM230C|1SCA129242R1001|101| OTM630...800E2CM230V OTM630...800E3CM230C OTM1000...1250E3CM230C OTM1000...1250E4CM230C OTM1600E2CM230V 1) OTM2000...3200: Category AC-21B OTM1600E4CM230C 2) 2-pole versions, motor voltage Ue 220...240V AC/DC Handles and bolt kits included as standard |**Suitable for switches**|**Handle**|**Bolt kit**| |---|---|---| |OTM630...800|OTV800ECMK|M12x40| |OTM1000...2500|OTV1000ECMK|M12x60| OTM2000...2500E3CM230C Recommended accessories: Bridging bars and voltage sensing connectors See pages 69-70 OTM2000...2500E4CM230C 58 | 1SCC303003C0201 | Transfer, change-over and bypass switches ## Motorized change-over switches Ordering information for OTM160...OTM2500_CM OTM160...250E3CM110V Motorized change-over switches, open transition, OTM160…OTM2500_CM Delivered with a handle for manual operation, bolt kit with nut and M washers for all terminals and male connectors for control circuits. Types OTM160…2500E_ include a storage clip for the handle and spare fuses. 110VAC/DC Types OTM160…250E_W are equipped with extended phase distance. OTM160...250E4WCM110V OTM315...400E3CM110V OTM630...800E4CM110V OTM1000...1250E4CM110V OTM1600E3CM230C |3|160|110|160/160|OTM160E3CM110V|1SCA022845R8530|6.6| |---|---|---|---|---|---|---| |3|160|110|160/160|OTM160E3WCM110V|1SCA022846R3450|6.9| |4|160|110|160/160|OTM160E4CM110V|1SCA022846R1080|7.5| |4|160|110|160/160|OTM160E4WCM110V|1SCA022846R7360|7.9| |3|200|135|200/200|OTM200E3CM110V|1SCA022845R8880|6.6| |3|200|135|200/200|OTM200E3WCM110V|1SCA022846R3880|6.9| |4|200|135|200/200|OTM200E4CM110V|1SCA022846R1410|7.5| |4|200|135|200/200|OTM200E4WCM110V|1SCA022846R7790|7.9| |3|250|170|250/250|OTM250E3CM110V|1SCA022845R9180|6.6| |3|250|170|250/250|OTM250E3WCM110V|1SCA022846R4690|6.9| |4|250|170|250/250|OTM250E4CM110V|1SCA022846R1830|7.5| |4|250|170|250/250|OTM250E4WCM110V|1SCA022846R8170|7.9| |3|315|215|315/315|OTM315E3CM110V|1SCA022847R1120|11.1| |4|315|215|315/315|OTM315E4CM110V|1SCA022847R2790|12.5| |3|400|275|400/400|OTM400E3CM110V|1SCA022847R1550|11.1| |4|400|275|400/400|OTM400E4CM110V|1SCA022847R3170|12.5| |3|630|435|650/650|OTM630E3CM110V|1SCA022873R1050|22| |4|630|435|650/650|OTM630E4CM110V|1SCA022873R1810|25| |3|800|550|720/650|OTM800E3CM110V|1SCA022872R5750|22| |4|800|550|720/650|OTM800E4CM110V|1SCA022872R8260|25| |3|1000|680|1000/1000|OTM1000E3CM110V|1SCA113653R1001|55| |4|1000|680|1000/1000|OTM1000E4CM110V|1SCA113656R1001|65| |3|1250|850|1250/1000|OTM1250E3CM110V|1SCA113652R1001|55| |4|1250|850|1250/1000|OTM1250E4CM110V|1SCA113655R1001|65| |3|1600|1000|1600/1000|OTM1600E3CM110V|1SCA113654R1001|59| |4|1600|1000|1600/1000|OTM1600E4CM110V|1SCA113657R1001|69| |3|2000|1350||OTM2000E3CM110V|1SCA113683R1001|78| |4|2000|1350||OTM2000E4CM110V|1SCA113685R1001|95| |3|2500|1700||OTM2500E3CM110V|1SCA113684R1001|78| |4|2500|1700||OTM2500E4CM110V|1SCA113686R1001|95| 1) OTM2000...2500: Category AC-21B OTM2000...2500E4CM110V ## Handles and bolt kits included as standard |**Suitable for switches**|**Handle**|**Bolt kit**| |---|---|---| |OTM160...250|OTV250ECMK|M8x25| |OTM315...400|OTV400ECMK|M10x30| |OTM630...800|OTV800ECMK|M12x40| |OTM1000...2500|OTV1000ECMK|M12x60| Recommended accessories: Bridging bars and voltage sensing connectors See pages 69-70 Transfer, change-over and bypass switches | 1SCC303003C0201 | 59 Motorized change-over switches Ordering information for OTM160...OTM2500_CM OTM160...250E3CM48D OTM160...250E4WCM48D OTM315...400E4CM48D OTM630...800E3CM48D OTM1000...1250E4CM48D OTM1600E3CM48D Motorized change-over switches, open transition, OTM160…OTM2500_C Delivered with a handle for manual operation, bolt kit with nut and washers for all terminals and male connectors for control circuits. Types OTM160…2500E_ include a storage clip for the handle and spare fuses. Types OTM160…250E_W are equipped with extended phase distance. M 48VDC **==> picture [366 x 426] intentionally omitted <==** **----- Start of picture text -----**<br> |||||||| |---|---|---|---|---|---|---| |Rated|Rated| |current|[1)]|Rated|current| |No.|AC-21A,|power|AC-31B/|Weight/| |of|AC-22A|400V|AC-33B|unit| |poles|≤ 415V, I[A]|S[kVA]|415V, I[A]|Type|Order number|[kg]| |Motor voltage Ue 48 V DC| |3|160|110|160/160|OTM160E3CM48D|1SCA022845R8450|6.6| |3|160|110|160/160|OTM160E3WCM48D|1SCA022846R3370|6.9| |4|160|110|160/160|OTM160E4CM48D|1SCA022846R0940|7.5| |4|160|110|160/160|OTM160E4WCM48D|1SCA022846R7280|7.9| |3|200|135|200/200|OTM200E3CM48D|1SCA022845R8700|6.6| |3|200|135|200/200|OTM200E3WCM48D|1SCA022846R3700|6.9| |4|200|135|200/200|OTM200E4CM48D|1SCA022846R1320|7.5| |4|200|135|200/200|OTM200E4WCM48D|1SCA022846R7610|7.9| |3|250|170|250/250|OTM250E3CM48D|1SCA022845R9000|6.6| |3|250|170|250/250|OTM250E3WCM48D|1SCA022846R4510|6.9| |4|250|170|250/250|OTM250E4CM48D|1SCA022846R1750|7.5| |4|250|170|250/250|OTM250E4WCM48D|1SCA022846R8090|7.9| |4|315|215|315/315|OTM315E4CM48D|1SCA022847R2610|11.1| |3|400|275|400/400|OTM400E3CM48D|1SCA022847R1470|12.5| |4|400|275|400/400|OTM400E4CM48D|1SCA022847R3090|11.1| |3|315|215|315/315|OTM315E3CM48D|1SCA022847R1040|12.5| |3|630|435|650/650|OTM630E3CM48D|1SCA022873R1300|22| |4|630|435|650/650|OTM630E4CM48D|1SCA022873R2110|25| |3|800|550|720/650|OTM800E3CM48D|1SCA022872R6050|22| |4|800|550|720/650|OTM800E4CM48D|1SCA022872R8510|25| |3|1000|680|1000/1000|OTM1000E3CM48D|1SCA113663R1001|55| |4|1000|680|1000/1000|OTM1000E4CM48D|1SCA113666R1001|65| |3|1250|850|1250/1000|OTM1250E3CM48D|1SCA113662R1001|55| |4|1250|850|1250/1000|OTM1250E4CM48D|1SCA113665R1001|65| |3|1600|1000|1600/1000|OTM1600E3CM48D|1SCA113664R1001|59| |4|1600|1000|1600/1000|OTM1600E4CM48D|1SCA113667R1001|69| |3|2000|1350|OTM2000E3CM48D|1SCA113689R1001|78| |4|2000|1350|OTM2000E4CM48D|1SCA113691R1001|95| |3|2500|1700|OTM2500E3CM48D|1SCA113690R1001|78| |4|2500|1700|OTM2500E4CM48D|1SCA113692R1001|95| **----- End of picture text -----**<br> 1) OTM2000...2500: Category AC-21B OTM2000...2500E4CM48D ## Handles and bolt kits included as standard **==> picture [308 x 56] intentionally omitted <==** **----- Start of picture text -----**<br> |||| |---|---|---| |Suitable for switches|Handle|Bolt kit| |OTM160...250|OTV250ECMK|M8x25| |OTM315...400|OTV400ECMK|M10x30| |OTM630...800|OTV800ECMK|M12x40| |OTM1000...2500|OTV1000ECMK|M12x60| **----- End of picture text -----**<br> Recommended accessories: Bridging bars and voltage sensing connectors See pages 69-70 60 | 1SCC303003C0201 | Transfer, change-over and bypass switches ## Motorized change-over switches Ordering information for OTM160...OTM2500_CM OTM160...250E3CM24D Motorized change-over switches, open transition, OTM160…OTM2500_C Delivered with a handle for manual operation, bolt kit with nut and washers for all terminals and male connectors for control circuits. Types OTM160…2500E_ include a storage clip for the handle and spare fuses. Types OTM160…250E_W are equipped with extended phase distance. M . 24VDC OTM160...250E4WCM24D OTM315...400E4CM24D OTM630...800E3CM24D OTM1000...1250E4CM24D OTM1600E3CM24D |3|160|110|160/160|OTM160E3CM24D|1SCA022845R8110|6.6| |---|---|---|---|---|---|---| |3|160|110|160/160|OTM160E3WCM24D|1SCA022846R3290|6.9| |4|160|110|160/160|OTM160E4CM24D|1SCA022846R0860|7.5| |4|160|110|160/160|OTM160E4WCM24D|1SCA022846R7100|7.9| |3|200|135|200/200|OTM200E3CM24D|1SCA022845R8290|6.6| |3|200|135|200/200|OTM200E3WCM24D|1SCA022846R3610|6.9| |4|200|135|200/200|OTM200E4CM24D|1SCA022846R1240|7.5| |4|200|135|200/200|OTM200E4WCM24D|1SCA022846R7520|7.9| |3|250|170|250/250|OTM250E3CM24D|1SCA022845R8370|6.6| |3|250|170|250/250|OTM250E3WCM24D|1SCA022846R4420|6.9| |4|250|170|250/250|OTM250E4CM24D|1SCA022846R1670|7.5| |4|250|170|250/250|OTM250E4WCM24D|1SCA022846R7950|7.9| |3|315|215|315/315|OTM315E3CM24D|1SCA022847R0910|11.1| |4|315|215|315/315|OTM315E4CM24D|1SCA022847R2520|12.5| |3|400|275|400/400|OTM400E3CM24D|1SCA022847R1390|11.1| |4|400|275|400/400|OTM400E4CM24D|1SCA022847R2950|12.5| |3|630|435|650/650|OTM630E3CM24D|1SCA022873R1210|22| |4|630|435|650/650|OTM630E4CM24D|1SCA022873R2020|25| |3|800|550|720/650|OTM800E3CM24D|1SCA022872R5910|22| |4|800|550|720/650|OTM800E4CM24D|1SCA022872R8420|25| |3|1000|680|1000/1000|OTM1000E3CM24D|1SCA113672R1001|55| |4|1000|680|1000/1000|OTM1000E4CM24D|1SCA113675R1001|65| |3|1250|850|1250/1000|OTM1250E3CM24D|1SCA113671R1001|55| |4|1250|850|1250/1000|OTM1250E4CM24D|1SCA113674R1001|65| |3|1600|1000|1600/1000|OTM1600E3CM24D|1SCA113673R1001|59| |4|1600|1000|1600/1000|OTM1600E4CM24D|1SCA113676R1001|69| |3|2000|1350||OTM2000E3CM24D|1SCA113695R1001|78| |4|2000|1350||OTM2000E4CM24D|1SCA113697R1001|95| |3|2500|1700||OTM2500E3CM24D|1SCA113696R1001|78| |4|2500|1700||OTM2500E4CM24D|1SCA113698R1001|95| 1) OTM2000...2500: Category AC-21B OTM2000...2500E4CM48D ## Handles and bolt kits included as standard |**Suitable for switches**|**Handle**|**Bolt kit**| |---|---|---| |OTM160...250|OTV250ECMK|M8x25| |OTM315...400|OTV400ECMK|M10x30| |OTM630...800|OTV800ECMK|M12x40| |OTM1000...2500|OTV1000ECMK|M12x60| Recommended accessories: Bridging bars and voltage sensing connectors See pages 69-70 Transfer, change-over and bypass switches | 1SCC303003C0201 | 61 ## Motorized change-over switches Dimensional drawings ## OTM40...125F3/4_CM **==> picture [454 x 342] intentionally omitted <==** **----- Start of picture text -----**<br> M00352/OTM30-125F_C_M A<br>116<br>115 99<br>33,5 108 52 83<br>7 Ø4,5 22,5 26 75<br>40<br>10<br>1 1 4<br>=e == g alll lew =e<br>EN50022<br>OTM<br>60<br>45 35<br>90<br>wee Ci rs an za 3 e HiiB 100 RN 65<br>6,5 44<br>26,5 56 80 56 74,5 35<br>12 12<br>14 65<br>12<br>16<br>12<br>230 ( 3-pole )<br>283 ( 4-pole )<br>**----- End of picture text -----**<br> **==> picture [487 x 134] intentionally omitted <==** **----- Start of picture text -----**<br> 66<br>OTM160...250E2/3/4CM A2<br>134,5127 659,0 20 23 3 83<br>OTM160-250_C_M<br>[mm] E2 E3 E4<br>A 35 35 35 100 122 14<br>A1 130<br>A1 116 116 116 130 150<br>65<br>A2 223 258 293<br>B 238 273 308<br>25 20<br>48,5 72<br>M00111 / OTM160-250E_C_M E 162 A | 25 —<br>160 37<br>re ae B for ae<br>87,5<br>**----- End of picture text -----**<br> 62 | 1SCC303003C0201 | Transfer, change-over and bypass switches ## Motorized change-over switches Dimensional drawings **==> picture [491 x 573] intentionally omitted <==** **----- Start of picture text -----**<br> 66<br>OTM160...250E2/3/4WCM<br>OTM160-250_WCM<br>ee [mm] E2 E3 E4 cil e |<br>A 43 43 43<br>A1 116 116 116<br>A2 239 282 325<br>B sn 254 297 340 n i a l l a<br>eee M00115 / OTM160-250E_WC_M E ec. r y ]<br>81<br>A2<br>OTM315...400E2/3/4CM<br>146 95 11 56 4 126<br>137,25 25 87<br>OTM315-400_C_M 32,5<br>[mm] E2 E3 E4<br>A 44 44 44 156A1 150 17<br>A1 142 142 142 120 160<br>A2 261 305 349 185<br>B 280 323 367 95<br>M00113 / OTM315-400E_C_M F 20,5<br>185,25 A<br>[ee] 192 43 [ul]<br>31,25<br>— tT B ae [P] [es]<br>A2 110,5<br>OTM630...800E2/3/4CM 158<br>147,5 39 64,1 5 132,6 138,6<br>OTM630-800E_C_M 13,5 61,5 45<br>[mm] E2 E3 E4 145<br>A 65 65 65<br>200 198<br>A1 180 180 180<br>A1 210<br>A2 325 390 455 160 250 17<br>B 346 411 476<br>M00140 / OTM630-800E02-04C_M C<br>20,5<br>212,5 A 47,5 256<br>43<br>B<br>A2<br>87,5<br>134,5 65 20 23 3 83<br>127 9,0<br>25<br>100 122 14<br>A1 130<br>130 150<br>170 65<br>170 A 25<br>48,5 72 20<br>B<br>160 37<br>25<br>**----- End of picture text -----**<br> Transfer, change-over and bypass switches | 1SCC303003C0201 | 63 ## Motorized change-over switches Dimensional drawings **==> picture [488 x 408] intentionally omitted <==** **----- Start of picture text -----**<br> OTM1000...1250E2/3/4CM<br>335<br>OTM1000-1250_C_M A2 167<br>80<br>[mm] E2 E3 E4 13,5 50 158,5<br>A 80 80 80 186 74,5 15 127<br>200 50<br>A1 230 230 230 171 136 100<br>A2 296,5 476,5 556,5<br>B 426,5 506,5 586,5<br>306 272<br>A1 400<br>M00256 / OTM1000-1250E_C_M C 260 250<br>206 M<br>Man.<br>19<br>253 A 63<br>296,5<br>B<br>75<br>._ 15<br>OTM1600E2/3/4CM A2 335<br>186 200 158,5 167<br>OTM1600_C_M Ø13,5 50 74,5 15 127<br>[mm] E2 E3 E4 171 136<br>100 83<br>A 80 80 80<br>A1 230 230 230<br>260 338 400<br>A2 396,6 476,5 556,5 A1 246 326<br>B 426,5 506,5 586,5 372 258<br>206 M<br>M00258 / OTM1600E_C_M C Man.<br>19<br>253 A 63<br>B 296,5<br>15<br>75<br>**----- End of picture text -----**<br> 64 | 1SCC303003C0201 | Transfer, change-over and bypass switches ## Motorized change-over switches Dimensional drawings OTM2000...2500E3/4CM **==> picture [487 x 418] intentionally omitted <==** **----- Start of picture text -----**<br> A2 335<br>OTM2000-2500_C_M 200 158,5 127167<br>[mm] E2 E3 E4 Ø 13,5 100 15 1 36<br>A 126 126 126 186171 74,5 100 85<br>A1 230 230 230<br>a Seka 376,4 | /<br>A2 488,5 614,5 740,5 260 262,4 342,4 400<br>B 518,5 644,5 770,5 A1 330,4 206<br>M00259 / OTM2000-2500E_C_M C 206 Man.M 250,4<br>19<br>276 A<br>86 296,5<br>15<br>B 75<br>OT3200E2/3/4CM A A2 429 245<br>200 F a n |ferrriie 14 er 1 iaeraeey<br>OTM3200_C_M 100<br>Ø13,5 223 15 (OTM3200)<br>[mm] E2 E3 E4 156,5 20181 (OTM4(OTM4000000) )<br>AA1 i 140 250 i 140250 i 250140 186171 H We] [es | 63 191 (OTM3200) 85 iu<br>A2 521,5 661,5 801,5 400<br>284<br>B 551,5 691,5 831,5 A1 296 376<br>280 364 410 240<br>M00432/OTM3200-4000_C_M A 206<br>100,5 4,8<br>170,5<br>73<br>15<br>61<br>258 A 325377<br>B 424<br>**----- End of picture text -----**<br> Transfer, change-over and bypass switches | 1SCC303003C0201 | 65 ## Optional accessories for motorized change-over switches Ordering information for handles and storage clips ## Plastic handle, direct mounting, indication I-O-II Includes a shaft and a mechanism cover. The type and ordering numbers are for one piece. OTV400ECMK |**Suitable**<br>**for**<br>**switches**||**Colour**||**Type**||**Order number**|**Delivery**<br>**batch**<br>**[pcs]**|**Weight/**<br>**unit**<br>**[kg]**| |---|---|---|---|---|---|---|---|---| |**Padlockable with three padlocks in 0-position. Types -ECMK include also microswitches.**||**Padlockable with three padlocks in 0-position. Types -ECMK include also microswitches.**||||||| |OTM160…250_C||Black||OTV250ECMK||1SCA022804R0570|1|0.10| |OTM315…400_C||Black||OTV400ECMK||1SCA022843R2900|1|0.28| |OTM630…800_C||Black||OTV800ECMK||1SCA022804R3410|1|0.32| |OTM1000…2500_C||Black||OTV1000ECMK||1SCA111301R1001|1|0.77| Handle and spare fuse storage clip for motorized change-over switches OTVS0 OTM40...125F_, the handle can be stored in the handle storage clip OTVS0. The clip can be fixed to a panel frame using the included adhesive tape. OTM160...3200E_, the handle and two spare fuses can be stored in the OTVS1 and OTVS2. OTVS1 and OTVS2 can be installed onto the left side of the switch. Snap-on mounting, no tools required. On OTM160...3200E_, the size of the handle prevents the installation onto the switch frame. However, the handle clip can be installed separately onto the panel frame and the fuse holder clip onto the switch frame. OTVS1 |**Suitable**<br>**for**<br>**switches**|**Type**|**Order number**|**Units/**<br>**type**<br>**[pcs]**|**Weight/**<br>**unit**<br>**[kg]**| |---|---|---|---|---| |OTM40...125F|OTVS0|1SCA117524R1001|1|0.02| |OTM160…250E_|OTVS1|1SCA111413R1001|1|0.02| |OTM315…3200E_|OTVS2|1SCA111414R1001|1|0.04| 66 | 1SCC303003C0201 | Transfer, change-over and bypass switches ## Optional accessories for motorized change-over switches Ordering information for terminal shrouds ## Terminal shrouds, grey plastic OTS_T3 Snap-on mounting to the switches, IP 20. A kit includes three or four shrouds which can be used on either side of the switch. Suitable for the upperswitch. Transparent shrouds for OTM160...3200 available on request, please replace the letter “G” with “T”. OTS_T1 OTS_L_ OTS_S_ |**Suitable**<br>**for**<br>**switches**|**No.**<br>**of**<br>**poles**|**Description**|**Type**|**Order number**|**Units/**<br>**type**<br>**[pcs]**|**Weight/**<br>**unit**<br>**[kg]**| |---|---|---|---|---|---|---| |OTM40...125F_|||OTS125T3|1SCA022379R9680|10|0.01| |OT_160…250_C|3|Long type|OTS250G1L/3|1SCA022731R8150|3|0.09| |OT_160…250_C|3|Short type|OTS250G1S/3|1SCA022731R8310|3|0.06| |OT_160…250_C|4|Long type|OTS250G1L/4|1SCA022731R8230|4|0.12| |OT_160…250_C|4|Short type|OTS250G1S/4|1SCA022731R8400|4|0.08| |OT_315…400_C|3|Long type|OTS400G1L/3|1SCA022736R8840|3|0.15| |OT_315…400_C|3|Short type|OTS400G1S/3|1SCA022736R9060|3|0.09| |OT_315…400_C|4|Long type|OTS400G1L/4|1SCA022736R9490|4|0.20| |OT_315…400_C|4|Short type|OTS400G1S/4|1SCA022736R9650|4|0.12| |OT_600…800_C|3|Long type|OTS800G1L/3|1SCA022776R7890|3|0.32| |OT_600…800_C|3|Short type|OTS800G1S/3|1SCA022776R8190|3|0.17| |OT_600…800_C|4|Long type|OTS800G1L/4|1SCA022776R7970|4|0.42| |OT_600…800_C|4|Short type|OTS800G1S/4|1SCA022776R8270|4|0.26| |OT_1000…1600_C|3|Long type|OTS1600G1L/3|1SCA022871R9510|3|0.64| |OT_1000…1600_C|3|Short type|OTS1600G1S/3|1SCA022871R9600|3|0.37| |OT_1000…1600_C|4|Long type|OTS1600G1L/4|1SCA022871R9780|4|0.85| |OT_1000…1600_C|4|Short type|OTS1600G1S/4|1SCA022871R9860|4|0.49| |OT_2000…2500_C|3|Long type|OTS2500G1L/3|1SCA107261R1001|3|0.77| |OT_2000…2500_C|3|Short type|OTS2500G1S/3|1SCA107260R1001|3|0.47| |OT_2000…2500_C|4|Long type|OTS2500G1L/4|1SCA107262R1001|4|1.00| |OT_2000…2500_C|4|Short type|OTS2500G1S/4|1SCA107271R1001|4|0.61| |OT3200_C|3|Long type|OTS4000G1L/3|1SCA129042R1001|3|1.20| |OT3200_C|3|Short type|OTS4000G1S/3|1SCA129044R1001|3|1.00| |OT3200_C|4|Long type|OTS4000G1L/4|1SCA129043R1001|4|1.40| |OT3200_C|4|Short type|OTS4000G1S/4|1SCA129045R1001|4|1.60| Transfer, change-over and bypass switches | 1SCC303003C0201 | 67 ## Optional accessories for motorized change-over switches Ordering information for phase barriers ## Phase barriers The phase barriers designed for ABB Tmax T4-T5 MCCB’s can also be used for OT_160...800 change-over switches. 3-pole change-overs need 8 barriers and 4-pole change-overs need 12 barriers for full protection. OTB_ PB_ |**Suitable**<br>**for**<br>**switches**|**No.**<br>**of**<br>**poles**|**Height**<br>**h**<br>**[mm]**|**Cutting**<br>**width W**<br>**of the**<br>**phase**<br>**barrier**<br>**[mm]**|**Type**|**Order number**|**Units/**<br>**type**<br>**[pcs]**| |---|---|---|---|---|---|---| |OT_160…250E_C|3|100|55|PB100 low|1SDA054970R1|4| |OT_160…250E_C|3|200|55|PB200 high|1SDA054972R1|4| |OT_160…250E_C|4|100|55|PB100 low|1SDA054971R1|6| |OT_160…250E_C|4|200|55|PB200 high|1SDA054973R1|6| |OT_315…400E_C|3|100|67|PB100 low|1SDA054970R1|4| |OT_315…400E_C|3|200|67|PB200 high|1SDA054972R1|4| |OT_315…400E_C|4|100|67|PB100 low|1SDA054971R1|6| |OT_315…400E_C|4|200|67|PB200 high|1SDA054973R1|6| |OT_600...800E_C|3|100|90|PB100 low|1SDA054970R1|4| |OT_600...800E_C|3|200|90|PB200 high|1SDA054972R1|4| |OT_600...800E_C|4|100|90|PB100 low|1SDA054971R1|6| |OT_600...800E_C|4|200|90|PB200 high|1SDA054973R1|6| ## Ordering information for terminal clamps Terminal clamp sets for Al- and Cu-cables insulated versions OZXT1 |**Suitable**<br>**for**<br>**switches**<br>~~:~~|**Cable cross**<br>**section**<br>**[mm2]**<br>~~:~~<br>~~——E~~|**Type**<br>~~——E~~|**Order number**<br>~~——E~~|**Units/**<br>**type**<br>**[pcs]**<br>~~——E~~|**Weight/**<br>**unit**<br>**[kg]**<br>~~——E~~| |---|---|---|---|---|---| |OTM40...125F_<br>~~:~~|16...50 Al/2.5...50 Cu<br>~~:~~<br>~~——E~~|OZXT1<br>~~——E~~|1SCA022469R6310<br>~~——E~~|3<br>~~——E~~|0.06<br>~~——E~~| |OTM63...125F_|16...120 Al/Cu|OZXT2|1SCA022620R7200|3|0.21| |OTM63...125F_|2x(16...50) Al/Cu|OZXT3|1SCA022639R0720|3|0.21| OZXT2...3 OZXT6 68 | 1SCC303003C0201 | Transfer, change-over and bypass switches ## Optional accessories for motorized change-over switches Ordering information for bridging- and reversing bars ## Bridging bars The bridging bars provide a connection link either on the incoming or outcoming side of the switch. **==> picture [43 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> OTZC13...34<br>**----- End of picture text -----**<br> OTZC43...44 OTZC53...54 |**Suitable**<br>**for**<br>**switches**|**No.**<br>**of**<br>**poles**|**Type**|**Order number**|**Units/**<br>**type**<br>**[pcs]**|**Weight/**<br>**unit**<br>**[kg]**| |---|---|---|---|---|---| |OT_160…250_C|3|OTZC13|1SCA022767R6910|3|0.6| |OT_160…250_C|4|OTZC14|1SCA022767R7040|4|0.8| |OT_315…400_C|3|OTZC23|1SCA022767R7120|3|0.6| |OT_315…400_C|4|OTZC24|1SCA022767R7210|4|0.8| |OT_600_C…800E_C|3|OTZC33|1SCA022785R7020|3|1.0| |OT_600_C…800E_C|4|OTZC34|1SCA022785R7110|4|1.3| |OT_1000…1250E_C|3|OTZC43|1SCA022868R0710|3|4.2| |OT_1000…1250E_C|4|OTZC44|1SCA022868R0800|4|5.6| |OT800U_, OT_1600E_C|3|OTZC53|1SCA022868R0980|3|5.6| |OT800U_, OT_1600E_C|4|OTZC54|1SCA022868R1010|4|7.4| |OT_2000…2500E_C|3|OTZC63|1SCA022868R1100|3|10.8| |OT_2000…2500E_C|4|OTZC64|1SCA022868R1360|4|14.5| |OT_3200E_C|3|OTZC73|1SCA128843R1001|3|14.1| |OT_3200E_C|4|OTZC74|1SCA128844R1001|4|18.7| ## Correct mounting of bridging bars onto the switch shown here. ## Reversing bars A reversing switch can be built by using phase sequence bars in two phases. The kit includes two phase sequence conversion bars. The missing bridging bars must be ordered separately, see above. For example 3-pole switches: one 4-pole standard bridging bar kit is required (one bar for the reversing side, three bars for the other side). OTZR_ |**Suitable**<br>**for**<br>**switches**|**Type**|**Order number**|**Units/**<br>**type**<br>**[pcs]**|**Weight/**<br>**unit**<br>**[kg]**| |---|---|---|---|---| |OT_160…250_C|OTZR1|1SCA100352R1001|2|0.3| |OT_315…400_C|OTZR2|1SCA104647R1001|2|0.3| |OT_600_C…800E_C|OTZR3|1SCA100355R1001|2|0.4| Transfer, change-over and bypass switches | 1SCC303003C0201 | 69 ## Optional accessories for motorized change-over switches Ordering information for voltage sensing connector ## Voltage sensing connectors* OMZB18...28 For 0.5...1.5mm[2] voltage sensing connection of the top or bottom power poles. The connector package includes also the faston terminals (see the picture). One package includes 8 connectors and 8 faston terminals. Wires are not included. OMZB38 |**Suitable**<br>**for**<br>**switches**|**Faston terminal**<br>**cable cross section**<br>**[mm2]**|**Type**|**Order number**|**Units/**<br>**type**<br>**[pcs]**|**Weight/**<br>**unit**<br>**[kg]**| |---|---|---|---|---|---| |OT_160…250_C|0.5…1.5|OMZB18|1SCA120153R1001|8|0.2| |OT_315…400_C|0.5…1.5|OMZB28|1SCA120154R1001|8|0.2| |OT_630…800E_C|0.5…1.5|OMZB38|1SCA120155R1001|8|0.2| |OT_1000…3200_C|0.5…1.5|OMZB48|1SCA120156R1001|8|0.2| * Terminal clamp OZXT6 is recommended to use with OTM40...125_C for voltage sensing connection. Terminal clamp OZXT6 includes 0.75...2.5 mm[2] voltage sensing connection. See ordering information on page 55. **==> picture [49 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> OMZB18...28<br>**----- End of picture text -----**<br> Correct mounting of voltage sensing connectors onto the switch shown here. OMZB48 ## Ordering information for parallel connection kits ## Parallel connection kits Finger protected connection bars for parallel connection of the upper or lower terminals. The bars accept additional cables, the maximum size is stated below. OMZC_ |**Suitable**<br>**for**<br>**switches**|**Cable cross**<br>**section**<br>**[mm2]**|**Type**|**Order number**|**Units/**<br>**type**<br>**[pcs]**|**Weight/**<br>**unit**<br>**[kg]**| |---|---|---|---|---|---| |OTM40F3C_|2.5...25/2x2.5...16|OMZC003|1SCA121324R1001|1|0.5| |OTM40F4C_|2.5...25/2x2.5...16|OMZC004|1SCA121325R1001|1|0.65| |OTM40…125F3C_|10...70|OMZC03|1SCA117037R1001|1|0.5| |OTM40…125F4C_|10...70|OMZC04|1SCA117038R1001|1|0.65| 70 | 1SCC303003C0201 | Transfer, change-over and bypass switches ## Optional accessories for motorized change-over switches Ordering information and technical data for auxiliary contacts ## Auxiliary contact blocks for OTM40…125F Snap-on mounting to the switch, IP 20, max. 2 blocks/ side. Ith = 16 A, suitable for cable cross sections max. 2 x 2,5 mm[2] . Simultaneous action with the main contacts. OA1G01 OA7G10 |**Suitable**<br>**for**<br>**switches**|**Contact**<br>**functions**|**Installation**<br>**side**|**Type**|**Order number**|**Delivery**<br>**batch**<br>**[pcs]**|**Weight/**<br>**unit**<br>**[kg]**| |---|---|---|---|---|---|---| |OT_16...125F_C|1NO|Right|OA1G10|1SCA022353R4970|10|0.03| |OT_16...125F_C|1NC|Right|OA8G01|1SCA022744R2240|10|0.03| |OT_16...125F_C|1NO|Left|OA7G10|1SCA022673R1140|10|0.03| |OT_16...125F_C|1NC|Left|OA1G01|1SCA022353R4890|10|0.03| |OT63...125F3C|1NO+1NC|Either|OA2G111)|1SCA022379R8100|10|0.03| 1) Not mountable on 4-pole change-over switches ## Auxiliary contact blocks for OTM160…3200 **OA1G10 OA8G01** Mounting on the right side of the switch: Max. 4 auxiliary contact blocks/switch (totally 8 blocks). Types _AU have gold plated contacts for harsh environments and low operating voltages. Simultaneous action with the main contacts, IP20. |**Suitable**<br>**for**<br>**switches**|**Contact**<br>**functions**|**Installation**<br>**side**|**Type**|**Order number**|**Delivery**<br>**batch**<br>**[pcs]**|**Weight/**<br>**unit**<br>**[kg]**| |---|---|---|---|---|---|---| |OT_160…3200_|1NO|Right|OA1G10|1SCA022353R4970|10|0.03| |OT_160…3200_|1NC|Right|OA3G01|1SCA022456R7410|10|0.03| |OT_160…3200_|1NO|Right|OA1G10AU|1SCA022436R7910|10|0.03| |OT_160…3200_|1NC|Right|OA3G01AU|1SCA022819R5260|10|0.03| **OA2G11** ## Auxiliary contacts |**AC15**|**AC15**|**AC15**|**DC12**|**DC12**|**DC13**|**DC13**| |---|---|---|---|---|---|---| |**Ue/[V]**|**Ie/[A]**|**Ue/[V]**|**Ie/[A]**|**P/[W]**|**Ie/[A]**|**P/[W]**| |230|6|24|10|240|2|50| |400|4|72|4|290|0.8|60| |415|4|125|2|250|0.55|70| |690|2|250|0.55|140|0.27|70| |||440|0.1|44||| ## Function tables |Function tables|Function tables|Function tables|Function tables|Function tables| |---|---|---|---|---| |**Function table of OT160…3200, OT160...800_Y and OTM160…2500 auxiliary contacts / Switch I (max. 2+2)**||||| |**Handleposition**|**Main contacts**||**OA1G10 NO**|**OA3G01 NC**| |I|closed||closed|open| |0|open||open|closed| |II|closed||open|closed| |**Function table of OT160…3200, OT160...800_Y and OTM160…2500 auxiliary contacts / Switch II (max. 2+2)**||||| |**Handleposition**|**Main contacts**||**OA1G10 NO**|**OA3G01 NC**| |I|closed||open|closed| |0|open||open|closed| |II|closed||closed|open| Transfer, change-over and bypass switches | 1SCC303003C0201 | 71 ## Optional accessories for motorized change-over switches Ordering information for automatic control units and related accessories ## Automatic control units OMD automatic control units can be used with OTM40...3200 motorized change-over switches in order to assemble an automatic transfer switch. The type and ordering codes include the OMD control unit, PCB connectors and 2 OMZD1 fasteners for door mounting. ## If used with OTM40…125_CMA_: OMD200 1 x OTM40…125_CMA_ motorized change-over switch and 2 or 3 x OZXT6 terminal clamp sets (including voltage sensing connection) must be ordered separately to be able to assemble an automatic transfer switch. ## If used with OTM160…3200_CM_: 1 x OTM160…3200_CM_ motorized change-over switch, 1 x OMZB_ voltage sensing connectors and 2 x OA1G10 auxiliary contacts must be ordered separately to be able to assemble an automatic transfer switch. The control unit can be mounted on a door or on DIN rail. OMD300 |**Suitable**<br>**for**<br>**switches**|**Type**|**Order number**|**Units/**<br>**type**<br>**[pcs]**|**Weight/**<br>**unit**<br>**[kg]**| |---|---|---|---|---| |OTM40…3200_CM_|OMD200E480C-A1|1SCA123789R1001|1|0.8| |OTM40…3200_CM_|OMD300E480C-A1|1SCA123790R1001|1|1.0| |OTM40…3200_CM_<br>:|OMD800E480C-A1<br>:<br>:|1SCA123791R1001<br>:<br>:|1<br>:<br>:|1.3| ## Panel fasteners OMD800 For mounting the OMD automatic control unit on the door. The type and ordering code is for 1 piece, so 2 units must be ordered for mounting the control on the door. |**Suitable**<br>**for OMD control unit**<br>,|**Type**<br>,<br>,|**Order number**<br>,<br>,|**Units/type**<br>**[pcs]**<br>,| |---|---|---|---| |OMD200_, OMD300_, OMD800_<br>,<br>~~_~~<br>~~l—EEFEEEEEEEEE~~|OMZD1<br>,<br>,<br>~~l—EEFEEEEEEEEE~~|1SCA022787R5190<br>,<br>,<br>~~eee~~|1<br>,<br>~~eee~~| OMZD1 ## Cover plate Providing protection against accidental contact. Padlockable transparent cover. The type and ordering codes are for 1 piece. |**Suitable**<br>**for OMD control unit**|**Type**|**Order number**|**Units/type**<br>**[pcs]**| |---|---|---|---| |OMD200_, OMD300_, OMD800_|OMZC2|1SCA101001R1001|1| OMZC2 72 | 1SCC303003C0201 | Transfer, change-over and bypass switches ## Optional accessories for motorized change-over switches Technical data and dimensional drawings for automatic control units ## Technical data for automatic control units OMD200/300/800 ## **OMD200 and OMD300** **==> picture [527 x 318] intentionally omitted <==** **----- Start of picture text -----**<br> Rated operational voltage Ue 208 V AC - 480 V AC +/- 20% + N<br>Phase - Neutral 120 V AC - 277 V AC +/- 20%<br>Rated frequency 50 / 60 Hz +/- 10%<br>Voltage sensing precision 5%<br>Frequency sensing precision 1%<br>Relay ratings: X21, X22 12 A, AC1, 250 V / 12 A, DC1, 24 V<br>X23, X24 8 A, AC1, 250 V / 8 A, DC1, 24 V<br>X26, X27, X28 10 A, AC1, 250 V / 5 A, DC1, 24 V<br>Rated impulse withstand voltage, Uimp 6 kV<br>Overvoltage category III<br>Pollution degree 2<br>OMD800<br>Rated operational voltage Ue on 3 phase system 100 V AC - 480 V AC +/- 20%<br>Phase - Neutral 57,7 V AC - 277 V AC +/- 20%<br>Rated operational voltage U e on 1 phase system [1)] 57,7 V AC - 277 V AC +/- 20%<br>Rated frequency 50 / 60 Hz +/- 10%<br>Voltage sensing precision 1%<br>Frequency sensing precision 1%<br>Relay ratings: X21, X22, X24 12 A, AC1, 250 V / 12 A, DC1, 24 V<br>X23 8 A, AC1, 250 V / 8 A, DC1, 24 V<br>X29 5 A, AC1, 250 V / 6 A, DC1, 24 V<br>Rated impulse withstand voltage, Uimp 6 kV<br>Overvoltage category III<br>Pollution degree 2<br>AUX voltage [1)] 24 V DC - 110 V DC (-10% to +15%)<br>Protection rating for the front panel IP40<br>Operating temperature – 20...+ 60 °C<br>Transportation and storage temperature – 25...+ 80 °C<br>Altitude Max. 2000m<br>Humidity<br>With condensation 5 %...98 %<br>Without condensation 5 %...90 %<br>**----- End of picture text -----**<br> 1) If on 1 phase system the voltage level is between 57,7 – 109 V AC, AUX voltage supply must be used OMD200/300/800 **==> picture [527 x 209] intentionally omitted <==** **----- Start of picture text -----**<br> 96 170<br>OMD<br>144<br>138<br>150<br>90<br>**----- End of picture text -----**<br> Transfer, change-over and bypass switches | 1SCC303003C0201 | 73 ## Optional accessories for motorized change-over switches Ordering information for dual power sources ## Dual power source Provides power supply to the motor operator by using two lines. The device has two inputs, from line I (LN I) and line II (LN II), and one output for the motor operator. The motor operator is automatically energized whenever power is available in one of the lines. Can be used with 230VAC motor operators. Snap-on mounted PCB connectors are included in the delivery. The device can be DIN-rail or screw mounted. ODPSE230C |**Suitable**|||||||**Units/**|**Weight/**| |---|---|---|---|---|---|---|---|---| |**for**|||||||**type**|**unit**| |**switches**|||||**Type**|**Order number**|**[pcs]**|**[kg]**| |OTM40…3200_|||||ODPSE230C|1SCA116892R1001|1|0.3| ||Line 1|Line 1|ODPS||Motor<br>operator<br>M|||| |G|Line 2|Line 2||||||| Connection diagram, ODPSE230C ## Dual power source including ATS functionality Similar to previous dual power source but also including ATS (Automatic Transfer Switch) functionality and in-built short-circuit protection. Provides power supply to the motor operator by using two 220...240 V AC lines. Motor operator is automatically energized whenever power is available in one of the lines. The device has a three position (AUTO-MAN-O) DIP switch to choose the correct operating mode. The AUTO position enables and the MAN position disables the ATS functionality when used with OTM motorized change-over switch. The O position is used for safety reasons: it operates the OTM to position 0 to isolate the load from the feeding sources. The device can be DIN-rail or screw mounted. ODPS230 **==> picture [383 x 186] intentionally omitted <==** **----- Start of picture text -----**<br> Suitable Units/ Weight/<br>for type unit<br>switches Type Order number [pcs] [kg]<br>OTM40…3200_ ODPS230 1SCA122946R1001 1 0.3<br>I Il<br>LN1 LN2<br>L N ODPS230 L N OTM_<br>Motorized<br>change-over switch<br>L N ET C II I 0 PE N L C II I 0<br>(pt _<br>**----- End of picture text -----**<br> Connection diagram, ODPS230 74 | 1SCC303003C0201 | Transfer, change-over and bypass switches ## Optional accessories for motorized change-over switches Technical data and dimensional drawings for dual power sources Technical data for dual power source ODPSE230C |**Dualpower source ODPSE230C**|| |---|---| |Rated operational voltage U[V]|220…240 V AC +/- 20%| |Rated frequency|50 / 60 Hz +/- 10%| |Short-circuitprotection device|Max. MCB 4 A| |Nominal output current I~~n~~ [A]|4 A| |~~n~~<br>Startuptime|Max. 1.0 s(with 230 V AC)| |Operatingtransfer time LN1 - LN2 or LN2 - LN1|Max. 0.5 s(with 230 V AC)| |Cable size|0,2…2,5 mm2| |Rated impulse withstand voltage,Uimp|4 kV| |Overvoltage category|III| |Pollution degree|3| |Protection ratingfor the frontpanel|IP20| |Operatingtemperature|– 25...+ 60 °C| |Transportation and storage temperature|– 40...+ 70 °C| |Altitude|Max. 2 000m| Technical data for new dual power source ODPS230 with ATS functionality |**Dualpower source ODPS230**|| |---|---| |Rated operational voltage U[V]|220…240 V AC,50 / 60 Hz| |Maximum voltage|288 V AC| |Pick-upvoltage|≥198 V AC| |Drop-out voltage|≤154 V AC| |Operatingtime|1 s ± 0.5 s| |Nominal output current I~~n~~ [A]|3,15 A| |~~n~~<br>Rated conditional short-circuit current,I~~p~~ (r.m.s.)|50 kA| |~~p~~<br>Internal fuse|T/3,15A/H*| |Fuse size|6,3 x 32 mm| |Rated impulse withstand voltage,U~~imp~~|4 kV| |~~imp~~<br>Overvoltage category|III| |Pollution degree|3| |Cable size|Max. 6 mm2| |Protection ratingfor the frontpanel|IP20| |Operatingtemperature|– 25...+ 60 °C| |Transportation and storage temperature|– 40...+ 70 °C| |Altitude|Max. 2 000m| *[)] The breaking capacity must be 50 kA to achieve 50 kA Ip (r.m.s.) rating Dimensional drawings for dual power sources ODPS230 ODPSE230C **==> picture [200 x 143] intentionally omitted <==** **----- Start of picture text -----**<br> mm<br>eee<br>Ø4,5<br>DIA 0,18<br>90<br>45 100<br>100<br>90<br>50<br>64<br>S07294<br>**----- End of picture text -----**<br> **==> picture [161 x 165] intentionally omitted <==** **----- Start of picture text -----**<br> a 32 52<br>ODPS<br>LN1 78<br>4 LN2<br>43<br>27,4<br>90 35,3<br>130<br>12X11<br>12X12<br>12X13<br>**----- End of picture text -----**<br> Transfer, change-over and bypass switches | 1SCC303003C0201 | 75 **==> picture [241 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> 76 | 1SCC303003C0201 | Transfer, change-over and bypass switches<br>**----- End of picture text -----**<br> Automatic transfer switches Open transition from 160 to 1600 Amperes **==> picture [258 x 319] intentionally omitted <==** **----- Start of picture text -----**<br> Introduction to automatic transfer switches<br>General information 78<br>Product range 79<br>Type codes 80<br>Switching sequence and operating times 81<br>List of product functionalities 82<br>Technical data<br>OTM160...400_C_D 84<br>OTM630...1600_C_D 85<br>Technical data for power and control circuits 86<br>Ordering information<br>OTM160...OTM1600_C_D 87<br>Dimension drawings<br>Automatic transfer switches 90<br>Ordering information for optional accessories<br>Terminal shrouds 94<br>Phase barriers 95<br>Terminal clamps 96<br>Bridging- and reversing bars 97<br>Auxiliary contacts 98<br>Automatic control units and related accessories 99<br>Dual power sources 98<br>**----- End of picture text -----**<br> ABB’s automatic transfer switches provide virtually instantaneous automatic switching between power sources. Transfer, change-over and bypass switches | 1SCC303003C0201 | 77 ## Automatic transfer switches Instantaneous automatic switching between power sources ABB offers a wide selection of automatic transfer switches (ATS), from 160 to 1600 Amperes in range. They have the features and functionality that makes them suitable for diverse applications: industrial plants, docks, airports and data centers. ## Quick and easy solution All ATS products by ABB are delivered as a ready-to-use solution in which the OMD unit is pre-mounted at the factory prior to delivery. It is also possible to purchase the control units and motorized change-over switches as separate components, allowing you to build the automatic transfer switch yourself. ## Safe operations With automatic transfer switches by ABB safe ON LOAD operations with a handle is always easy and readily available. Our switches also come equipped with numerous other safety features such as the possibility to prevent unwanted operations by padlocking the handle into O position. ## Reliable functionality You can rest assured that your automatic transfer switch solution works as expected without the need to carry out any testing. The entire solution has been tested by ABB and is guaranteed to fulfill all the requirements according to the IEC60947-6-1 standard. ## Improved user experience Ensuring a high performance level and an easy and efficient user experience for you is of the utmost importance to us. Usage has been made simpler than ever before with an LCD display with menus available in eight languages. 78 | 1SCC303003C0201 | Transfer, change-over and bypass switches Automatic transfer switches Open transition from 160 to 1600 Amperes |**Automatic transfer switches, 160-400 A**||||||||| |---|---|---|---|---|---|---|---|---| |**Types**|OTM160E_C_D|||OTM160E_WC_D|||OTM315E_C_D|| ||OTM200E_C_D|||OTM200E_WC_D|||OTM400E_C_D|| ||OTM250E_C_D|||OTM250E_WC_D||||| |**lth /A**|**160**<br>**200**<br>**250**|||**160**<br>**200**<br>**250**|||**315**<br>**400**|| |le/AC-22A, < 415V|160|200|250|160|200|250|315|400| |le/AC-23A, < 415V|160|200|250|160|200|250|315|400| |le/AC-31B, < 415V|160|200|250|160|200|250|315|400| |**Automatic transfer switches 630-1600 A**|||||| |---|---|---|---|---|---| |**Types**|OTM630E_C_D||OTM1000E_C_D||OTM1600E_C_D| ||OTM800E_C_D||OTM1250E_C_D||| ||||||| |**lth /A**|**630**<br>**800**||**1000**<br>**1250**||**1600**| |le/AC-22A, < 415V|630|800|1000|1250|1600| |le/AC-23A, < 415V|630|800|1000|1250|1250| |le/AC-31B, < 415V|650|720|1000|1250|1600| OTM1600E_C_D Transfer, change-over and bypass switches | 1SCC303003C0201 | 79 ## Automatic transfer switches Type codes ## Type codes Understanding the type code keys below will help you quickly identify the correct product for your needs. The simple naming system allows you to see the products type, Ampere rating, standard classification and number of poles, all in one glance. ## **Explanation of the types OTM160...1600_C_D** **==> picture [391 x 214] intentionally omitted <==** **----- Start of picture text -----**<br> Option: OTM800 E 4 C 3 D 230 C<br>Position: 1 2 3 4 5 6 7 8<br>1 Brand and Switch size / Ampere rating<br>2 IEC<br>3 Number of the poles<br>4 Change over switch: I-0-II -operation<br>3: 3-poles<br>4: 4-poles<br>5 Place of sensing kit<br>_(blank): Voltage sensing kit on the top<br>B: Voltage sensign kit on the bottom<br>6 Automatic controlle unit<br>2D: OMD200<br>3D: OMD300<br>8D: OMD800<br>7 Voltage for motor operator<br>230: 220...240 V AC<br>8 Motor voltage type<br>V=AC/DC<br>**----- End of picture text -----**<br> 80 | 1SCC303003C0201 | Transfer, change-over and bypass switches ## Automatic transfer switches Switching sequence and operating times Example of switching sequence for automatic transfer switches An example of the switching sequence can be summarized in following steps: - An anomaly occurs on the Line 1 - Switching delay - Generator start - Delay on transfer - Change-over switch (Switch I) to the position O - Dead band I to II delay - Change-over switch (Switch II) to the position II The back switching sequence can be summarized in the following steps: - The Line 1 will start the normal functioning - Back switching delay - Change-over switch (Switch II) to the position O - Dead band II to I delay - Change-over switch (Switch I) to the position I - Generator stop delay - Generator stop The diagram is with OTM_C8D and Line 1 priority operating mode **==> picture [347 x 126] intentionally omitted <==** **----- Start of picture text -----**<br> LINE 1<br>LINE 2<br>Switch I status<br>Switch II status<br>Gen. START<br>A04155 Ts Tt Ds TBs DBs Gs<br>**----- End of picture text -----**<br> Ts: Switching delay, Tt: Delay on transfer, Ds: Dead band I to II, TBs: Back switching delay, DBs: Dead band II to I, Gs: Generator stop delay Automatic transfer switches operating times for OTM160...1600_ Operating times **==> picture [348 x 140] intentionally omitted <==** **----- Start of picture text -----**<br> Operating transfer time [a)] OFF-time when operating [a)]<br>Type I - II, II - I [s] I - II, II - I [s]<br>OTM160…250_C2D_ 2.0 - 4.0 0.4 - 1.0<br>OTM160…250_C3D_ 2.0 - 4.0 0.4 - 1.0<br>OTM160…250_C8D_ 1.5 - 3.0 0.4 - 1.0<br>OTM315…400_C2D_ 2.0 - 5.0 0.4 - 1.0<br>OTM315…400_C3D_ 2.0 - 5.0 0.4 - 1.0<br>OTM315…400_C8D_ 1.5 - 3.0 0.4 - 1.0<br>OTM630…800_C2D_ 2.0 - 5.0 0.4 - 1.0<br>OTM630…800_C3D_ 2.0 - 5.0 0.4 - 1.0<br>OTM630…800_C8D_ 1.5 - 3.0 0.4 - 1.0<br>OTM1000…1600_C2D_ 3.0 - 6.0 0.6 - 1.5<br>OTM1000…1600_C3D_ 3.0 - 6.0 0.6 - 1.5<br>OTM1000…1600_C8D_ 2.5 - 4.0 0.6 - 1.5<br>**----- End of picture text -----**<br> a) Under nominal conditions Transfer, change-over and bypass switches | 1SCC303003C0201 | 81 ## Automatic transfer switches List of product functionalities ## ==68b2"Bi ~~ee~~ Automatic transfer switches functionality |~~:~~|~~:~~|**OTM_C2D_**|~~:~~|~~:~~|**OTM_C3D_**|~~:~~|**OTM_C8D_**| |---|---|---|---|---|---|---|---| |**OTM_C_D products overview**|||||||| |Includes automatic control unit||OMD200_|||OMD300_||OMD800_| |Manual operation with handle<br>:||x|:||x|:|x| |Local operation with front panel keypad||x|||x||x| |Automatic transfer switching equipment (ATSE)||x|||x||x| |Dual power source for the motor operator1)||o|||x||o| |**Measurements**|||||||| |Three phase voltage measurement on LINE 1||x|||x||x| |Single phase voltage measurement on LINE 1||x|||x||x| |Three phase voltage measurement on LINE 2||x|||x||x| |Single phase voltage measurement on LINE 2||x|||x||x| |Frequency on LINE 1||x|||x||x| |Frequency on LINE 2||x|||x||x| |Possibility to check the measurements via LCD|||||||x| |**Source failure detections**|||||||| |No voltage||x|||x||x| |Undervoltage||x|||x||x| |Overvoltage||x|||x||x| |Phase missing||x|||x||x| |Voltage unbalance||x|||x||x| |Invalid frequency||x|||x||x| |Incorrect phase sequence|||||||x| |**Configuration**|||||||| |By DIP switches||x|||x||| |By rotary switches||x|||x||| |By keypad and LCD|||||||x| |Voltage threshold setting||x|||x||x| |Voltage hysteresis setting|||||||x| |Frequency threshold setting|||||||x| |Frequency hysteresis setting|||||||x| |**Time delays**|||||||| |Switching delay||x2)|||x2)||0...60 s| |Delay on transfer3)|||||||0...600 s| |Dead band time I-II (stop switching to position O)|||||||0...60 s| |Back-switching delay||x4)|||x4)||0...5 400 s| |Dead band time II-I (stop switching to position O)|||||||0...60 s| |Generator stop delay||x5)|||x5)||0...1 800 s| |Status of time delays on the LCD|||||||x| - 1) Dual power source allows the motor operator to be supplied by two separate voltage supplies. This way the motor operator is always energized from the available line. - 2) Four options: 0, 5, 10 or 30 seconds - 3) Delaying the switching sequence before transferring to generator, guaranteeing that in cold locations the generator is properly warmed up - 4) Two options: the duration of back-switching delay is the same as switching delay, - i.e. the time delay is same for I - II and II - I, or the back-switching delay is fixed 300 seconds - 5) Two options: the duration of generator stop delay is the same as Switching delay or fixed 5 min - x = included as standard - = as an accessory 82 | 1SCC303003C0201 | Transfer, change-over and bypass switches ## Automatic transfer switches List of product functionalities ## Automatic transfer switches functionality |**Features**|||| |---|---|---|---| |Generator start and stop|x|x|x| |Off-load test sequence|x|x|x| |On-load test sequence|x|x|x| |Source status via front panel|x|x|x| |Source status via digital outputs|||x| |Switch position via front panel|x|x|x| |LCD6)|||x| |Fieldbus interface7)|||x| |Event/alarm log|||x| |Counter for number of operations|||x| |Auxiliary voltage supply8)|||x| |Programmable digital inputs (eight) and digital outputs (six)|||x| |Secondary load control (load shedding)|||x| |Digital input - Allow transfer to secondary9)|||x| |Digital input - Generator alarm10)|||x| |Digital input - Remote control to positions I, O and II|||x| - 6) Menus available in eight languages; English, French, German, Italian, Spanish, Russian, Chinese and Finnish 7) Two-way communication, bus communication protocol is Modbus 8) In case of source failure, the control unit can be supplied with an external auxiliary supply with 24…110 V DC 9) Control unit requires an external signal before allowing the transfer to secondary 10) Two options for the operating mode after receiving the alarm: control unit either works normally, or initiates generator stop with operation to position O 11) Two options: No line priority, or Source 1 is the priority source 12) Three options: No line priority, Source 1 or Source 2 is the priority source 13) Automatic back-switching to primary source is prevented 14) Control unit and motor operator must be energized x = included as standard o = as an accessory Transfer, change-over and bypass switches | 1SCC303003C0201 | 83 ## Automatic transfer switches Technical data for OTM160...400_C ## Automatic transfer switches **==> picture [527 x 528] intentionally omitted <==** **----- Start of picture text -----**<br> Switch size , OTM_<br>Data according to IEC 60947-3 OTM_160_ OTM_200_ OTM_250_ OTM_315_ OTM_400_<br>Rated insulation voltage and rated Pollution degree 3 [2)] V 1 000 1 000 1 000 1 000 1 000<br>operational voltage AC20/DC20 [1)]<br>Dielectric strength 50 Hz 1min. kV 10 10 10 10 10<br>Rated impulse withstand voltage [3)] kV 12 12 12 12 12<br>Rated thermal current and rated / ambient 40°C In open air A 160 200 250 315 400<br>operational current AC20/DC20 / ambient 40°C In enclosure A 160 200 250 315 400<br>..with minimum conductor cross section Cu mm [2] 70 95 120 185 240<br>Rated operational current, AC-21A up to 500 V A 160 200 250 315 400<br>690 V A 160 200 250 315 400<br>Rated operational current, AC-22A up to 500 V A 160 200 250 315 400<br> 690 V A 160 200 250 315 400<br>Rated operational current, AC-23A up to 415 V A 160 200 250 315 400<br>440 V A 160 200 250 315 400<br>500 V A 160 200 250 315 400<br>690 V A 160 200 250 315 400<br>Rated operational current / ≤ 110 V A 160/2 200/2 250/2 315/1 [4)] 400/1 [4)]<br>poles in series, DC-21A [10)] 220 V A 160/2 200/2 250/2 315/2 [4)] 400/2 [4)]<br>440 V A 160/3 200/3 230/3 315/3 360/3<br>660 V A 160/4 200/4 200/4 315/4 315/4<br>Rated operational power, AC-23A [5)] 230 V kW 45 60 75 100 132<br>The kW-ratings are accurate for 400 V kW 90 110 140 160 220<br>3-phase 1500 R.P.M. standard 415 V kW 90 110 145 180 230<br>asychronous motors<br>500 V kW 110 132 170 220 280<br>690 V kW 160 200 250 315 400<br>Rated breaking capacity up to 415 V A 1 280 1 600 2 000 2 520 3 200<br>in category AC-23 500 V A 1 280 1 600 2 000 2 520 3 200<br>690 V A 1 280 1 600 2 000 2 520 3 200<br>Rated conditional short-circuit current IThe cut-off current îlisted by fuse manufacturers p (r.m.s.) and cut-off current îc refers to values c(peak) value. Max. OFAIIpp (r.m.s.) 80 kA, 415 V (r.m.s.) 100 kA, 500 V_ fuse size gîîcc (peak) (peak)G/aM kAA/AkA 40.5355/31540.5 40.540.5355/315 40.540.5355/315 5961.5500/500 5961.5500/500<br>(single phase test acc. to IEC60269). Max. OFA_ fuse size gG/aM A 315/315 315/315 315/315 500/450 500/450<br>Ip (r.m.s.) 80 kA, 690 V îc (peak) kA 40.5 40.5 40.5 59 59<br>Max. OFA_ fuse size gG/aM A 355/315 355/315 355/315 500/500 500/500<br>Rated short-time withstand current Icw (r.m.s.) 690 V 0.15s kA 15 15 15 31 31<br>690 V 0.25s kA 15 15 15 24 24<br>690 V 1s kA 8 8 8 15 15<br>Rated short-time making capacity [6)] Icm (peak) [7)] 690 V kA 30 30 30 65 65<br>Power loss / pole With rated current W 2.4 4 6.5 6.5 10<br>Mechanical endurance Number of oper. cycles [8)] Cycles 8 000 8 000 8 000 8 000 8 000<br>Terminal bolt size Metric thread mm M8x25 M8x25 M8x25 M10x30 M10x30<br>diameter x length<br>Terminal tightening torque Counter torque required Nm 15-22 15-22 15-22 30-44 30-44<br>Operating torque Typical for 3-pole Nm 7 7 7 16 16<br>change-over switches<br>Weight without accessories Automatic 3-pole switch kg 5.7 5.7 5.7 10.2 10.2<br>transfer switches 4-pole switch kg 6.4 6.4 6.4 11.4 11.4<br>Data according to IEC 60947-6-1<br>Class of equipment PC PC PC PC PC<br>Rated short-time withstand current Icw (r.m.s.) 690 V 0.1s kA 15 15 15 25 25<br>Rated operational current, AC-31B up to 415 V A 160 200 250 315 400<br>Rated operational current, AC-33B up to 415 V A 160 200 250 315 400<br>**----- End of picture text -----**<br> - 1) Automatic transfer switches: operational voltage - = max. 415 V AC for OTM_C2D_, OTM_C3D_ and OTM_C8D_ - 2) Automatic transfer switches: pollution degree 2 for - OTM_C2D_, OTM_C3D_ and OTM_C8D_ - 3) Automatic transfer switches: Uimp = 6 kV for OTM_C2D_, OTM_C3D_ and OTM_C8D_ - 4) Utilization category B - 5) These values are given for guidance and may vary acc. to the motor manufacturer - 6) Short circuit duration > 50ms, without fuse protection - 7) Max. distance from switch frame to nearest busbar / cable support 150 mm - 8) Operating cycle: O - I - O - II - O - 9) Category AC-21B, up to 415V - 13) Further ratings on request 84 | 1SCC303003C0201 | Transfer, change-over and bypass switches ## Automatic transfer switches Technical data for OTM630...1600_C ## Automatic transfer switches **==> picture [528 x 527] intentionally omitted <==** **----- Start of picture text -----**<br> Switch size , OTM_<br>Data according to IEC 60947-3 OTM_630_ OTM_800_ OTM_1000_ OTM_1250_ OTM_1600_<br>Rated insulation voltage and rated Pollution degree 3 [2)] V 1 000 1 000 1 000 1 000 1 000<br>operational voltage AC20/DC20 [1)]<br>Dielectric strength 50 Hz 1min. kV 10 10 10 10 10<br>Rated impulse withstand voltage [3)] kV 12 12 12 12 12<br>Rated thermal current and rated / ambient 40°C In open air A 630 800 1 000 1 250 1 600<br>operational current AC20/DC20 / ambient 40°C In enclosure A 630 800<br>..with minimum conductor cross section Cu mm [2] 2x185 2x240 2x300 2x400 2x500<br>Rated operational current, AC-21A up to 500 V A 630 800 1 000 1 250 1 600<br>690 V A 630 800 1 000 1 250 1 600<br>Rated operational current, AC-22A up to 500 V A 630 800 1 000 1 250 1 600<br> 690 V A 630 800 1 000 1 250 1 600<br>Rated operational current, AC-23A up to 415 V A 630 800 1 000 1 250 1 250<br>440 V A 630 800 1 000 1 250 1 250<br>500 V A 630 800 1 000 1 250 1 250<br>690 V A 630 800 1 000 1 250 1 250<br>Rated operational current / ≤ 110 V A 630/1 800/1<br>poles in series, DC-21A [10)] 220 V A 630/1 800/1<br>440 V A 630/2 720/2<br>660 V A 630/4 [4)] 630/4 [4)]<br>Rated operational power, AC-23A [5)] 230 V kW 200 250 315 400 400<br>The kW-ratings are accurate for 400 V kW 355 450 560 710 710<br>3-phase 1500 R.P.M. standard 415 V kW 355 450 560 710 710<br>asychronous motors<br>500 V kW 400 560 710 900 900<br>690 V kW 630 800 1 000 1 200 1 200<br>Rated breaking capacity up to 415 V A 5 040 6 400 10 000 10 000 10 000<br>in category AC-23 500 V A 5 040 6 400 10 000 10 000 10 000<br>690 V A 5 040 6 400 10 000 10 000 10 000<br>Rated conditional short-circuit current IThe cut-off current îlisted by fuse manufacturers p (r.m.s.) and cut-off current îc refers to values c(peak) value. Max. OFAIIpp (r.m.s.) 80 kA, 415 V (r.m.s.) 100 kA, 500 V_ fuse size gîîcc (peak) (peak)G/aM kAkAA/A 83.590800/1 000 800/1 00083.590 1001061 250/1 250 1001061 250/1 250 1001061 250/1 250<br>(single phase test acc. to IEC60269). Max. OFA_ fuse size gG/aM A 800/800 800/800 1 250/1 250 1 250/1 250 1 250/1 250<br>Ip (r.m.s.) 80 kA, 690 V îc (peak) kA 83.5 83.5<br>Max. OFA_ fuse size gG/aM A 800/1 000 800/1 000<br>Rated short-time withstand current Icw (r.m.s.) 690 V 0.15s kA 38 38 50 50 50<br>690 V 0.25s kA 36 36 50 50 50<br>690 V 1s kA 20 20 50 50 50<br>Rated short-time making capacity [6)] Icm (peak) [7)] 690 V kA 80 80 92 92 92<br>Power loss / pole With rated current W 25 40 19 29 48<br>Mechanical endurance Number of oper. cycles [8)] Cycles 5 000 5 000 3 000 3 000 3 000<br>Terminal bolt size Metric thread mm M12x40 M12x40 M12x60 M12x60 M12x60<br>diameter x length<br>Terminal tightening torque Counter torque required Nm 50-75 50-75 50-75 50-75 50-75<br>Operating torque Typical for 3-pole Nm 27 27 78 78 78<br>change-over switches<br>Weight without accessories Automatic 3-pole switch kg 17.5 17.5 42 42 44<br>transfer switches 4-pole switch kg 20.4 20.4 50 50 52<br>Data according to IEC 60947-6-1<br>Class of equipment PC PC PC PC PC<br>Rated short-time withstand current Icw (r.m.s.) 690 V 0.1s kA 38 38 50 50 50<br>Rated operational current, AC-31B up to 415 V A 650 720 1 000 1 250 1 600<br>Rated operational current, AC-33B up to 415 V A 650 650 1 000 1 000 1 000<br>**----- End of picture text -----**<br> - 1) Automatic transfer switches: operational voltage - = max. 415 V AC for OTM_C2D_, OTM_C3D_ and OTM_C8D_ - 2) Automatic transfer switches: pollution degree 2 for OTM_C2D_, OTM_C3D_ and OTM_C8D_ - 3) Automatic transfer switches: Uimp = 6 kV for OTM_C2D_, OTM_C3D_ and OTM_C8D_ - 4) Utilization category B - 5) These values are given for guidance and may vary acc. to the motor manufacturer - 6) Short circuit duration > 50ms, without fuse protection - 7) Max. distance from switch frame to nearest busbar / cable support 150 mm - 8) Operating cycle: O - I - O - II - O - 9) Category AC-21B, up to 415V - 13) Further ratings on request Transfer, change-over and bypass switches | 1SCC303003C0201 | 85 ## Automatic transfer switches Technical data for power and control circuits ## Technical data for automatic transfer switches, power circuit **==> picture [527 x 197] intentionally omitted <==** **----- Start of picture text -----**<br> OTM_C2D_ (OMD200)<br>Rated operational voltage Ue 208 - 415 V AC +/- 20 % + N<br>Phase - Neutral 120 - 240 V AC +/- 20 %<br>Rated frequency 50 / 60 Hz +/- 10 %<br>Rated impulse withstand voltage Uimp 6 kV<br>OTM_C3D_ (OMD300)<br>Rated operational voltage Ue 208 - 415 V AC +/- 20 % + N<br>Phase - Neutral 120 - 240 V AC +/- 20 %<br>Rated frequency 50 / 60 Hz +/- 10 %<br>Rated impulse withstand voltage Uimp 6 kV<br>OTM_C8D_ (OMD800)<br>Rated operational voltage Ue on 3 phase system 100 - 415 V AC +/- 20 %<br>Phase - Neutral 57,7 - 240 V AC +/- 20 %<br>Rated operational voltage U e on 1 phase system [1)] 57,7 - 240 V AC +/- 20 %<br>Rated frequency 50 / 60 Hz +/- 10 %<br>Rated impulse withstand voltage Uimp 6 kV<br>AUX voltage [1)] 24 V DC - 110 V DC (-10 to 15 %)<br>Operating temperature - 5…+40°C<br>Transportation and storage temperature - 25…+70°C<br>Altitude Max.2 000m<br>**----- End of picture text -----**<br> 1) If on 1 phase system the voltage level is between 57,7 – 109 V AC, AUX voltage supply must be used Technical data for motor operator, control circuit **==> picture [526 x 258] intentionally omitted <==** **----- Start of picture text -----**<br> Motor operator, control circuit OTM160…250 OTM315…400 OTM630…800 OTM1000…1600<br>Rated operational voltage U [V] Pollution degree 3 50/60 Hz 220 - 240 V AC<br>Operating voltage range 0,8…1,2 x U e<br>Operating times See the table below<br>Nominal current Ina) A 0.2 0.5 0.7 1.8<br>Current Inrush [a)] A 1.3 2.1 2.8 7.7<br>Overload fuse Type / In / Capacity mA T/315/H T/500/H T/1 000/H T/2 000/H<br>Size mm 5x20 5x20 5x20 5x20<br>Operating rate Cycle 0 - I - 0 - II - 0<br>Max. continuous cycles / min 1 1 1 0.5<br>Max. short-time ≤ 10 cycles cycles / min 10 10 10 5<br>Overvoltage category III<br>Rated impulse withstand voltage Uimp kV 4<br>Dielectric strength 50 Hz 1 min. kV 1.5<br>Terminals<br>Voltage supply wiring for U PE - N - L<br>Cross section solid/stranded mm [2] 1.5 - 2.5<br>Short-circuit protection device max. MCB A C16<br>State information of locking (no SELV)<br>Cross section solid/stranded mm [2] 1.5 - 2.5<br>Locking motor operator 23-24 (NO) 5A/250V/cos ϕ =1<br>Short-circuit protection device Max. MCB A C2<br>Protection degree IP20<br>Operating temperature °C -25…+55<br>Transportation and storage temperature °C -40…+70<br>Max. altitude m 2 000<br>**----- End of picture text -----**<br> 86 | 1SCC303003C0201 | Transfer, change-over and bypass switches Automatic transfer switches Ordering information for OTM160…OTM1600_C **==> picture [442 x 328] intentionally omitted <==** **----- Start of picture text -----**<br> 3<br>3<br>CO) 2<br>i<br>6<br>ag<br>ne<br>”<br>7<br>———— |<br>hoi * 4<br>5<br>®<br>4<br>y Ai<br>SS -<br>| O 1<br>**----- End of picture text -----**<br> ## Automatic transfer switch accessory guide 1. Automatic transfer switch 5. Storage for handle and fuses 2. Terminal clamp 3. Terminal shroud 6. Bridging bar 7. Cover plate 4. Auxiliary contact Please note that not all listed accessories are automatically included in your order. See next page for recommendations. Voltage sensing connection is part of standard delivery and factory fitted. Transfer, change-over and bypass switches | 1SCC303003C0201 | 87 ## Automatic transfer switches Ordering information for OTM160...OTM1600_C Automatic transfer switches, open transition, OTM160…OTM1600_C Delivered with a handle for manual operation, PCB connectors, bolt kit with nuts and washers for all terminals. Voltage sensing connections are part of standard delivery and factory fitted. Types OTM160…1600_C_D_ include a voltage sensing kit on the top of the switch. Please note that OTM_C2D types are equipped with OMD200 control units, while OTM_C3D types are equipped with OMD300 control units. OTM160...250E4C_D230C To ensure suitability and easy installation, these products are also available with the voltage sensing kit installed onto the bottom of the switch. Simply add the letter “B” to the typecode when ordering. For example,OTM160E4C2D230C OTM160E4C **B** 2D230C. Types OTM160...1600E_ include a storage clip for the handle and spare fuses. Types OTM160...250_WC_D_ are equipped with extended phase distance. OTM160...250E4WC_D230C OTM315...400E4C_D230C OTM630...800E4C_D230C |4|160|110|160/160|OTM160E4C2D230C|1SCA106230R1001|11| |---|---|---|---|---|---|---| |4|160|110|160/160|OTM160E4WC2D230C|1SCA101033R1001|11| |4|200|135|200/200|OTM200E4C2D230C|1SCA106671R1001|11| |4|200|135|200/200|OTM200E4WC2D230C|1SCA101034R1001|11| |4|250|170|250/250|OTM250E4C2D230C|1SCA101016R1001|11| |4|250|170|250/250|OTM250E4WC2D230C|1SCA101035R1001|11| |4|315|215|315/315|OTM315E4C2D230C|1SCA101059R1001|15| |4|400|275|400/400|OTM400E4C2D230C|1SCA101060R1001|15| |4|630|435|650/650|OTM630E4C2D230C|1SCA108434R1001|37| |4|800|550|720/650|OTM800E4C2D230C|1SCA108439R1001|37<br>~~a~~| |4|1000|680|1000/1000|OTM1000E4C2D230C<br>~~“snd~~|1SCA112858R1001<br>~~“snd~~<br>~~—~~|66<br>~~a~~<br>~~—~~| |4|1250|850|1250/1000<br>~~ERIE~~|OTM1250E4C2D230C<br>~~cxcccccocce0~~<br>~~“snd~~<br>~~ee:~~|1SCA112857R1001<br>~~“snd~~<br>~~ee:~~<br>~~—~~|66<br>~~—~~| |4|1600|1000<br>||1600/1000<br>|<br>~~ERIE~~|OTM1600E4C2D230C<br>~~cx cccccocce0~~<br>~~ee:~~|1SCA112854R1001<br>~~ee:~~|70| **Automatic operation, OTM_C3D_ types, voltage sensing on the top. Voltage sensing connection included as standard.** Including in-built dual power source for the motor operator. Motor operator voltage Ue = 220...240 V AC[1)] OTM1000...1250E4C_D230C OTM1600E4C_D230C |4|160|110|160/160|OTM160E4C3D230C|1SCA106305R1001|11| |---|---|---|---|---|---|---| |4|160|110|160/160|OTM160E4WC3D230C|1SCA106306R1001|11| |4|200|135|200/200|OTM200E4C3D230C|1SCA106309R1001|11| |4|200|135|200/200|OTM200E4WC3D230C|1SCA106310R1001|11| |4|250|170|250/250|OTM250E4C3D230C|1SCA106313R1001|11| |4|250|170|250/250|OTM250E4WC3D230C|1SCA106314R1001|11| |4|315|215|315/315|OTM315E4C3D230C|1SCA106317R1001|15| |4|400|275|400/400|OTM400E4C3D230C|1SCA106318R1001|15| |4|630|435|650/650|OTM630E4C3D230C|1SCA108726R1001|37| |4|800|550|720/650|OTM800E4C3D230C|1SCA108728R1001|37| |4|1000|680|1000/1000|OTM1000E4C3D230C|1SCA112852R1001|66| |4|1250|850|1250/1000|OTM1250E4C3D230C|1SCA112851R1001|66| |4|1600|1000|1600/1000|OTM1600E4C3D230C|1SCA112848R1001|70| 1) Under nominal conditions See next page for handles and bolt kits 88 | 1SCC303003C0201 | Transfer, change-over and bypass switches ## Automatic transfer switches Ordering information for OTM160...1600_C Automatic transfer switches, open transition, OTM160…OTM1600_C Delivered with a handle for manual operation, PCB connectors, bolt kit with nuts and washers for all terminals. Types OTM160…1600_C_D_ include a voltage sensing kit on the top of the switch. Please note that OTM_C2D types are equipped with OMD200 control units, while OTM_C3D types are equipped with OMD300 control units. OTM160E3C8D230C To ensure suitability and easy installation, these products are also available with the voltage sensing kit installed onto the bottom of the switch. Simply add the letter “B” to the typecode when ordering. For example,OTM160E4C2D230C OTM160E4C **B** 2D230C. Types OTM160...1600E_ include a storage clip for the handle and spare fuses. Types OTM160...250_WC_D_ are equipped with extended phase distance. OTM160...250E3WC8D230C OTM315...400E4C8D230C OTM630...800E4C8D230C OTM1000...1250E4C8D230C OTM1600E3C8D230C |3|160|110|160/160|OTM160E3C8D230C|1SCA101017R1001|10| |---|---|---|---|---|---|---| |3|160|110|160/160|OTM160E3WC8D230C|1SCA101036R1001|10| |4|160|110|160/160|OTM160E4C8D230C|1SCA101020R1001|11| |4|160|110|160/160|OTM160E4WC8D230C|1SCA101039R1001|11| |3|200|135|200/200|OTM200E3C8D230C|1SCA101018R1001|10| |3|200|135|200/200|OTM200E3WC8D230C|1SCA101037R1001|10| |4|200|135|200/200|OTM200E4C8D230C|1SCA101021R1001|11| |4|200|135|200/200|OTM200E4WC8D230C|1SCA101040R1001|11| |3|250|170|250/250|OTM250E3C8D230C|1SCA101019R1001|10| |3|250|170|250/250|OTM250E3WC8D230C|1SCA101038R1001|10| |4|250|170|250/250|OTM250E4C8D230C|1SCA101022R1001|11| |4|250|170|250/250|OTM250E4WC8D230C|1SCA101041R1001|11| |3|315|215|315/315|OTM315E3C8D230C|1SCA101062R1001|14| |4|315|215|315/315|OTM315E4C8D230C|1SCA101063R1001|15| |3|400|275|400/400|OTM400E3C8D230C|1SCA101061R1001|14| |4|400|275|400/400|OTM400E4C8D230C|1SCA101064R1001|15| |3|630|435|650/650|OTM630E3C8D230C|1SCA108452R1001|34| |4|630|435|650/650|OTM630E4C8D230C|1SCA108453R1001|37| |3|800|550|720/650|OTM800E3C8D230C|1SCA108454R1001|34| |4|800|550|720/650|OTM800E4C8D230C|1SCA108455R1001|37| |3|1000|680|1000/1000|OTM1000E3C8D230C|1SCA112868R1001|57| |4<br>~~a~~|1000|680|1000/1000|OTM1000E4C8D230C<br>i|1SCA112861R1001<br>i<br>E|66| |3<br>~~a~~|1250|850|1250/1000|OTM1250E3C8D230C<br>i|1SCA112862R1001<br>i<br>E|57| |4|1250|850|1250/1000|OTM1250E4C8D230C|1SCA112864R1001|66| |3|1600|1000|1600/1000|OTM1600E3C8D230C|1SCA112866R1001|60| |4|1600|1000|1600/1000|OTM1600E4C8D230C|1SCA112867R1001|70| 1) Under nominal conditions ## Handles and bolt kits included as standard |**Suitable for switches**|**Handle**|**Bolt kit**| |---|---|---| |OTM160...250|OTV250ECMK|M8x25| |OTM315...400|OTV400ECMK|M10x30| |OTM630...800|OTV800ECMK|M12x40| |OTM1000...1600|OTV1000ECMK|M12x60| Transfer, change-over and bypass switches | 1SCC303003C0201 | 89 Automatic transfer switches Dimensional drawings **==> picture [498 x 625] intentionally omitted <==** **----- Start of picture text -----**<br> 262 96<br>170<br>OTM160...250E_C_2D_<br>OTM160...250E_C_3D_ OMD<br>237<br>OT160-250_C_D_ 203144 I II OFFONI ONII 65 83/35,5<br>20<br>[mm] E3 E4 rr _ 105 020s 30 +5 % TEST+20% Ø9<br>A 35 35<br>A1 116 116<br>14 59 M A1 130<br>A2 257 292 130 Mon. 150<br>B 272 307 65 58 100 122<br>13 / OTM160-250E_C_2D_ C<br>20 3 127<br>25 72 48,5 162 A 25<br>37 160 A2<br>B<br>262<br>96<br>170<br>OTM160...250E_C_8D_<br>OMD<br>OT160-250_C_D_<br>237 144<br>[mm] E03 E04 65 83/35,5<br>203<br>A 35 35 20<br>A1 116 116 ONI OFF ONII Ø9<br>A2 257 292<br>B 272 307 14 59 M A1 130<br>130 Mon. 150<br>M00184 / OTM160-250E_C_8D_ C 58 100 122<br>65<br>|<br>20 3 127<br>25 72 48,5 162 A 25<br>37 160 — A2<br>B<br>262<br>170 96<br>OTM160...250E_WC_2D_<br>OTM160...250E_WC_3D_ OMD<br>OT160-250_WC_D_ [mm] A E3 43 E4 43 237203 k 144 I II OFFONI ONII 6520 Ø9 83/35,5<br>A1 116 116 105 020s 30 +5 % TEST+20%<br>A2 281 324 14 59 M 100 122 150<br>B 296 339 130 Man. A1 130 170<br>M00186 / OTM160-250E_WC_2D_ C 65 58<br>20 3 127<br>37 25 16072 48,5 170 A 25<br>A2<br>zea, B<br>**----- End of picture text -----**<br> 90 | 1SCC303003C0201 | Transfer, change-over and bypass switches ## Automatic transfer switches Dimensional drawings **==> picture [492 x 626] intentionally omitted <==** **----- Start of picture text -----**<br> 262 96<br>170<br>OTM160...250E_WC_8D_<br>OMD<br>OT160-250_WC_D_<br>237<br>[mm] E3 E4 144<br>A 43 43 65 Ø9 83/35,5<br>203<br>20<br>A1 116 116 ONI OFF ONII<br>A2 281 324<br>B 296 339 14 59 M 100 122 150<br>M00187 / OTM160-250E_WC_8D_ C 130 Man. A1 130 170<br>65 58<br>20 3 127<br>25 72 48,5 170 A 25<br>37 160 A2<br>B<br>294<br>,<br>170 96<br>OTM315...400E_C_2D_<br>OTM315...400E_C_3D OMD<br>OTM315-400_C_D_ [mm] E3 E4 247213144 I II OFFOFFONI ONOMDII 25 95 126/51,5<br>A 44 44 105 020s 30 +5 % TEST+20% Ø11<br>A1 142 142<br>A2 304,5 348,5 1 7 69 M A1 160<br>B 323 367 156 Man. 150 185<br>120<br>71<br>M00192 / OTM315-400E_C_2D_ C 95<br>4 137<br>32,5 87 56 185 A2 A 31<br>43 192<br>B<br>294<br>170 96<br>OTM315...400E_C_8D_<br>OTM315-400_C_D_ OMD<br>[mm] E3 E4 247 144 95<br>A 44 44<br>213 25<br>A1 142 142 ONI OFF ONII Ø11 126/51,5<br>A2 304,5 348,5<br>B 323 367<br>17 69 M A1 160<br>M00193 / OTM315-400E_C_8D_ C 156 Man. 185<br>150<br>120<br>71<br>95<br>4 137<br>32,5 87 56 185 A2 A 31<br>43 192 B<br>**----- End of picture text -----**<br> Transfer, change-over and bypass switches | 1SCC303003C0201 | 91 ## Automatic transfer switches Dimensional drawings **==> picture [492 x 388] intentionally omitted <==** **----- Start of picture text -----**<br> 355 96<br>OTM630...800E_C_2D_ 170<br>OTM630...800E_C_3D_ OMD<br>OMD 138,5 39 Ø13,5<br>144 OFFOFF<br>OTM630-800_C_D_ 267 I II ONI ONII<br>[mm] E2 E3 E4 105 020s 30 +5%TEST+20% 61,5<br>A 65 65 65 145 89 + +<br>A1 180 180 180 200 198 250<br>A2 325 390 455 160<br>B 346 411 476 17 90 A1 210<br>+ +<br>M00204 / OTM630-800E_C_2D_ C 45<br>5 147,5<br>132,5 64 212,5 A 47,5<br>43 256 A2<br>B<br>355 96<br>170<br>OTM630...800E_C_8D_<br>OMD<br>OTM630-800_C_D_ 138,5 39 Ø13,5<br>144<br>[mm] E2 E3 E4<br>A 65 65 65 267 ONI OFF ONII 61,5<br>A1 180 180 180 145 + +<br>89<br>A2 325 390 455 200 198 250<br>B 346 411 476 17 160 A1 210<br>90<br>M00205 / OTM630-800E_C_8D_ C + +<br>45<br>5 147,5<br>132,5 64 212,5 A 47,5<br>43 256 A2<br>B<br>+<br>+<br>**----- End of picture text -----**<br> **==> picture [5 x 5] intentionally omitted <==** **----- Start of picture text -----**<br> 96<br>**----- End of picture text -----**<br> |OTM1000...1250E_C2D_| |---| |OTM1000...1250E_C3D_| |OTM1000-1250E_C_D| |**[mm]**<br>**E2**<br>**E3**<br>**E4**| |A<br>80<br>80<br>80| |A1<br>230<br>230<br>230| |A2<br>396<br>476<br>556| |B<br>426<br>506<br>586| **==> picture [70 x 4] intentionally omitted <==** **----- Start of picture text -----**<br> M00262 / OTM1000_1250E2_4C2 B<br>**----- End of picture text -----**<br> 92 | 1SCC303003C0201 | Transfer, change-over and bypass switches ## Automatic transfer switches Dimensional drawings **==> picture [493 x 399] intentionally omitted <==** **----- Start of picture text -----**<br> 387 96<br>OTM1000...1250E_C_8D || a00<br>OTM1000-1250E_C_D<br>[mm] E2 E3 E4<br>A 80 80 80<br>A1 230 230 230<br>A2 396 476 556<br>a B 426 es 506 586 ral 260 5 ——— |_| 188<br>M00264 / OTM1000_1250E2_4C8 B<br>fd Hp 253 i ai L [ttes]<br>15 75 295<br>317<br>387 96<br>240 400<br>OTM1600E_C2D_ 170 [| A2<br>OMD<br>OTM1600E_C3D_<br>Ø13,5 50<br>290 144 OFF<br>OTM1600_C_D 256 I II ONI ONII<br>[mm] E2 E3 E4 105 020s 30 +5%TEST+20%<br>A 80 80 80 400 338<br>112 246<br>A1 230 230 230 260 326<br>A2B 396426 476506 556586 206 Man.M A1 258 372<br>iH oU NP.<br>M00268 / OTM1600E2-4C2D_ C 19<br>171<br>253 A 63<br>15 75 136 74,5 B<br>295<br>317<br>**----- End of picture text -----**<br> |OTM1000...1250E_C_8D|OTM1000...1250E_C_8D| |---|---| |OTM1000-1250E_C_D|| |**[mm]**<br>**E2**<br>**E3**|**E4**| |A<br>80<br>80|80| |A1<br>230<br>230|230| |A2<br>396<br>476|556| |B<br>426<br>506<br>~~a es~~|586| |M00264 / OTM1000_1250E2_4C8 B|| |OTM1600E_C8D_|OTM1600E_C8D_|OTM1600E_C8D_|OTM1600E_C8D_|OTM1600E_C8D_|OTM1600E_C8D_|OTM1600E_C8D_|||| |---|---|---|---|---|---|---|---|---|---| |OTM1600E_C_D|||||||||| |**[mm]**|||**E2**|||**E3**|||**E4**| |A<br>A1|H<br>:||80<br>230|:<br>:||80<br>230|H<br>:||80<br>230| |A2|||396|||476|||556| |B|||426|||506|||586| **==> picture [58 x 5] intentionally omitted <==** **----- Start of picture text -----**<br> M00269 / OTM1600E2_4C8 B<br>**----- End of picture text -----**<br> Transfer, change-over and bypass switches | 1SCC303003C0201 | 93 ## Optional accessories for automatic transfer switches Ordering information for terminal shrouds ## Terminal shrouds, grey plastic Snap-on mounting to the switches, IP 20. A kit includes three or four shrouds which can be used on either side of the switch. Suitable for the upperswitch. Transparent shrouds for OT_160…1600 available on request, please replace the letter “G” with “T”. OTS_L_ OTS_S_ |**No.**<br>**of**<br>**poles**|**Description**|**Type**|**Order number**|**Units/**<br>**type**<br>**[pcs]**| |---|---|---|---|---| |3|Long type|OTS250G1L/3|1SCA022731R8150|3| |3|Short type|OTS250G1S/3|1SCA022731R8310|3| |4|Long type|OTS250G1L/4|1SCA022731R8230|4| |4|Short type|OTS250G1S/4|1SCA022731R8400|4| |3|Long type|OTS400G1L/3|1SCA022736R8840|3| |3|Short type|OTS400G1S/3|1SCA022736R9060|3| |4|Long type|OTS400G1L/4|1SCA022736R9490|4| |4|Short type|OTS400G1S/4|1SCA022736R9650|4| |3|Long type|OTS800G1L/3|1SCA022776R7890|3| |3|Short type|OTS800G1S/3|1SCA022776R8190|3| |4|Long type|OTS800G1L/4|1SCA022776R7970|4| |4|Short type|OTS800G1S/4|1SCA022776R8270|4| |3|Long type|OTS1600G1L/3|1SCA022871R9510|3| |3|Short type|OTS1600G1S/3|1SCA022871R9600|3| |4|Long type|OTS1600G1L/4|1SCA022871R9780|4| |4|Short type|OTS1600G1S/4|1SCA022871R9860|4| 94 | 1SCC303003C0201 | Transfer, change-over and bypass switches ## Optional accessories for automatic transfer switches Ordering information for phase barriers ## Phase barriers The phase barriers designed for ABB Tmax T4-T5 MCCB’s can also be used for OT_160...800 change-over switches. 3-pole change-overs need 8 barriers and 4-pole change-overs need 12 barriers for full protection. PB_ |**No.**<br>**of**<br>**poles**|**Height**<br>**h**<br>**[mm]**|**Cutting**<br>**width W**<br>**of the**<br>**phase**<br>**barrier**<br>**[mm]**|**Type**|**Order number**| |---|---|---|---|---| |3|100|55|PB100 low|1SDA054970R1| |3|200|55|PB200 high|1SDA054972R1| |4|100|55|PB100 low|1SDA054971R1| |4|200|55|PB200 high|1SDA054973R1| |3|100|67|PB100 low|1SDA054970R1| |3|200|67|PB200 high|1SDA054972R1| |4|100|67|PB100 low|1SDA054971R1| |4|200|67|PB200 high|1SDA054973R1| |3|100|90|PB100 low|1SDA054970R1| |3|200|90|PB200 high|1SDA054972R1| |4|100|90|PB100 low|1SDA054971R1| |4|200|90|PB200 high|1SDA054973R1| Transfer, change-over and bypass switches | 1SCC303003C0201 | 95 ## Optional accessories for automatic transfer switches Ordering information for terminal clamps ## Terminal clamp sets for Al- and Cu-cables OZXB2L OZXB7L > [me] OZXB9 |**Suitable**<br>**for**<br>**switches**|**Cable cross**<br>**section**<br>**[mm2]**|**Suitable**<br>**shroud**|**Type **|**Order number**|**Units/**<br>**type**<br>**[pcs]**|**Delivery**<br>**batch**<br>**[pcs]**|**Weight/**<br>**unit**<br>**[kg]**| |---|---|---|---|---|---|---|---| |OT_160...250E_C|10...70|OTS250_L|OZXB1L|1SCA022169R2030|3|1|0.15| |OT_160...250E_C|10...70|OTS250_L|OZXB1L/1|1SCA022194R0030|1|50|0.05| |OT_160...250E_C|25...120|OZXB2K|OZXB2|1SCA022119R7610|3|1|0.34| |OT_160...250E_C|25...120|OZXB2K|OZXB2/1|1SCA022194R0200|1|50|0.12| |OT_160...250E_C|25...120|OZXB2K|OZXB2L|1SCA022158R7750|3|1|0.43| |OT_160...250E_C|25...120|OZXB2K|OZXB2L/1|1SCA022194R0460|1|50|0.15| |OT_160...250E_C|95...185|OTS250_L|OZXB8|1SCA022744R1510|3|1|0.50| |OT_160...250E_C|95...185|OTS250_L|OZXB8/1|1SCA022744R1600|1|20|0.15| |OT_160...250E_C|95...240|OTS250_L|OZXB9|1SCA022750R3210|3|1|0.50| |OT_160...250E_C|95...240|OTS250_L|OZXB9/1|1SCA022750R3300|1|20|0.15| |OT_315...400E_C<br>~~So:~~|25...120<br>~~:Sosia~~|OZXB2K<br>~~iaee Ss~~|OZXB2L<br>~~Ss=~~|1SCA022158R7750<br>~~=Oe — —~~|3<br>~~— —~~|1<br>~~— —:~~|0.43<br>~~:a~~| |OT_315...400E_C<br>~~So:~~|25...120<br>~~:Sosia~~|OZXB2K<br>~~iaee Ss~~|OZXB2L/1<br>~~Ss=~~|1SCA022194R0460<br>~~=Oe — —~~|1<br>~~— —~~|50<br>~~— —:~~|0.15<br>~~:a~~| |OT_315...400E_C<br>~~So:~~|70…185<br>~~:Sosia~~|OZXB3K<br>~~iaee Ss~~|OZXB3<br>~~Ss=~~|1SCA022136R8100<br>~~=Oe — —~~|3<br>~~— —~~|1<br>~~— —:~~|1.28<br>~~:a~~| |OT_315...400E_C<br>~~So:~~|70…185<br>~~:Sosia~~|OZXB3K<br>~~iaee Ss~~|OZXB3/1<br>~~Ss=~~|1SCA022194R0620<br>~~=Oe — —~~|1<br>~~— —~~|20<br>~~— —:~~|0.43<br>~~:a~~| |OT_315...400E_C|2x(70…185)|OZXB3K|OZXB4|1SCA022137R4760|3|1|1.71| |OT_315...400E_C|2x(70…185)|OZXB3K|OZXB4/1|1SCA022194R0890|1|20|0.57| |OT_315...400E_C|120...240|OZXB5K|OZXB7|1SCA022185R0040|3|1|1.00| |OT_315...400E_C|120...240|OZXB5K|OZXB7/1|1SCA022194R1430|1|20|0.34| |OT_315...400E_C|120...240|OZXB5K|OZXB7L|1SCA022185R7130|3|1|1.17| |OT_315...400E_C|120...240|OZXB5K|OZXB7L/1|1SCA022194R1600|1|20|0.40| |OT_315...400E_C|95...185|OTS400_L|OZXB8|1SCA022744R1510|3|1|0.50| |OT_315...400E_C|95...185|OTS400_L|OZXB8/1|1SCA022744R1600|1|20|0.15| |OT_315...400E_C|95...240|OTS400_L|OZXB9|1SCA022750R3210|3|1|0.50| |OT_315...400E_C|95...240|OTS400_L|OZXB9/1|1SCA022750R3300|1|20|0.15| 96 | 1SCC303003C0201 | Transfer, change-over and bypass switches ## Optional accessories for automatic transfer switches Ordering information for bridging- and reversing bars ## Bridging bars The bridging bars provide a connection link either on the incoming or outcoming side of the switch. OTZC13...34 OTZC43...44 OTZC53...54 |**Suitable**<br>**for**<br>**switches**|**No.**<br>**of**<br>**poles**|**Type**|**Order number**|**Units/**<br>**type**<br>**[pcs]**|**Weight/**<br>**unit**<br>**[kg]**| |---|---|---|---|---|---| |OT_160…250_C|3|OTZC13|1SCA022767R6910|3|0.6| |OT_160…250_C|4|OTZC14|1SCA022767R7040|4|0.8| |OT_315…400_C|3|OTZC23|1SCA022767R7120|3|0.6| |OT_315…400_C|4|OTZC24|1SCA022767R7210|4|0.8| |OT_600_C…800E_C|3|OTZC33|1SCA022785R7020|3|1.0| |OT_600_C…800E_C|4|OTZC34|1SCA022785R7110|4|1.3| |OT_1000…1250E_C|3|OTZC43|1SCA022868R0710|3|4.2| |OT_1000…1250E_C|4|OTZC44|1SCA022868R0800|4|5.6| |OT800U_, OT_1600E_C|3|OTZC53|1SCA022868R0980|3|5.6| |OT800U_, OT_1600E_C|4|OTZC54|1SCA022868R1010|4|7.4| |OT_2000...2500E_C|3|OTZC63|1SCA022868R1100|3|10.8| |OT_2000...2500E_C|4|OTZC64|1SCA022868R1360|4|14.5| |OT_3200E_C|3|OTZC73|1SCA128843R1001|3|14.1| |OT_3200E_C|4|OTZC74|1SCA128844R1001|4|18.7| ## Reversing bars A reversing switch can be built by using phase sequence bars in two phases. The kit includes two phase sequence conversion bars. The missing bridging bars must be ordered separately, see above. For example 3-pole switches: one 4-pole standard bridging bar kit is required (one bar for the reversing side, three bars for the other side). OTZR_ |**Suitable**<br>**for**<br>**switches**|**Type**|**Order number**|**Units/**<br>**type**<br>**[pcs]**|**Weight/**<br>**unit**<br>**[kg]**| |---|---|---|---|---| |OT_160…250_C|OTZR1|1SCA100352R1001|2|0.3| |OT_315…400_C|OTZR2|1SCA104647R1001|2|0.3| |OT_600_C…800E_C|OTZR3|1SCA100355R1001|2|0.4| Transfer, change-over and bypass switches | 1SCC303003C0201 | 97 Optional accessories for automatic transfer switches Ordering information and technical data for auxiliary contacts ## Auxiliary contact blocks for OTM40…125F Snap-on mounting to the switch, IP 20, max. 2 blocks/ side. Ith = 16 A, suitable for cable cross sections max. 2 x 2,5 mm[2] . Simultaneous action with the main contacts. OA1G01 OA7G10 |**Suitable**<br>**for**<br>**switches**|**Contact**<br>**functions**|**Installation**<br>**side**|**Type**|**Order number**|**Delivery**<br>**batch**<br>**[pcs]**|**Weight/**<br>**unit**<br>**[kg]**| |---|---|---|---|---|---|---| |OT_16...125F_C|1NO|Right|OA1G10|1SCA022353R4970|10|0.03| |OT_16...125F_C|1NC|Right|OA8G01|1SCA022744R2240|10|0.03| |OT_16...125F_C|1NO|Left|OA7G10|1SCA022673R1140|10|0.03| |OT_16...125F_C|1NC|Left|OA1G01|1SCA022353R4890|10|0.03| |OT63...125F3C|1NO+1NC|Either|OA2G111)|1SCA022379R8100|10|0.03| 1) Not mountable on 4-pole change-over switches ## Auxiliary contact blocks for OTM160…3200 **OA1G10 OA8G01** Mounting on the right side of the switch: Max. 4 auxiliary contact blocks/switch (totally 8 blocks). Types _AU have gold plated contacts for harsh environments and low operating voltages. Simultaneous action with the main contacts, IP20. |**Suitable**<br>**for**<br>**switches**|**Contact**<br>**functions**|**Installation**<br>**side**|**Type**|**Order number**|**Delivery**<br>**batch**<br>**[pcs]**|**Weight/**<br>**unit**<br>**[kg]**| |---|---|---|---|---|---|---| |OT_160…3200_|1NO|Right|OA1G10|1SCA022353R4970|10|0.03| |OT_160…3200_|1NC|Right|OA3G01|1SCA022456R7410|10|0.03| |OT_160…3200_|1NO|Right|OA1G10AU|1SCA022436R7910|10|0.03| |OT_160…3200_|1NC|Right|OA3G01AU|1SCA022819R5260|10|0.03| **OA2G11** ## Auxiliary contacts |**AC15**|**AC15**|**AC15**|**DC12**|**DC12**|**DC13**|**DC13**| |---|---|---|---|---|---|---| |**Ue/[V]**<br>**Ie/[A]**<br>**Ue/[V]**|||**Ie/[A]**|**P/[W]**|**Ie/[A]**|**P/[W]**| |230|6|24|10|240|2|50| |400|4|72|4|290|0.8|60| |415|4|125|2|250|0.55|70| |690|2|250|0.55|140|0.27|70| |||440|0.1|44||| ## Function tables |Function tables|Function tables|Function tables|Function tables|Function tables| |---|---|---|---|---| |**Function table of OT160…3200, OT160...800_Y and OTM160…2500 auxiliary contacts / Switch I (max. 2+2)**||||| |**Handleposition**|**Main contacts**||**OA1G10 NO**|**OA3G01 NC**| |I|closed||closed|open| |0|open||open|closed| |II|closed||open|closed| |**Function table of OT160…3200, OT160...800_Y and OTM160…2500 auxiliary contacts / Switch II (max. 2+2)**||||| |**Handleposition**|**Main contacts**||**OA1G10 NO**|**OA3G01 NC**| |I|closed||open|closed| |0|open||open|closed| |II|closed||closed|open| 98 | 1SCC303003C0201 | Transfer, change-over and bypass switches ## Optional accessories for automatic transfer switches Ordering information for automatic control units and related accessories ## Automatic control units OMD automatic control units can be used with OTM40...3200 motorized change-over switches in order to assemble an automatic transfer switch. The type and ordering codes include the OMD control unit, PCB connectors and 2 OMZD1 fasteners for door mounting. ## If used with OTM40…125_CMA_: OMD200 1 x OTM40…125_CMA_ motorized change-over switch and 2 or 3 x OZXT6 terminal clamp sets (including voltage sensing connection) must be ordered separately to be able to assemble an automatic transfer switch. ## If used with OTM160…3200_CM_: 1 x OTM160…3200_CM_ motorized change-over switch, 1 x OMZB_ voltage sensing connectors and 2 x OA1G10 auxiliary contacts must be ordered separately to be able to assemble an automatic transfer switch. The control unit can be mounted on a door or on DIN rail. OMD300 |**Suitable**<br>**for**<br>**switches**|**Type**|**Order number**|**Units/**<br>**type**<br>**[pcs]**|**Weight/**<br>**unit**<br>**[kg]**| |---|---|---|---|---| |OTM40…3200_CM_|OMD200E480C-A1|1SCA123789R1001|1|0.8| |OTM40…3200_CM_|OMD300E480C-A1|1SCA123790R1001|1|1.0| |OTM40…3200_CM_|OMD800E480C-A1|1SCA123791R1001|1|1.3| ## Panel fasteners OMD800 For mounting the OMD automatic control unit on the door. The type and ordering code is for 1 piece, so 2 units must be ordered for mounting the control on the door. |**Suitable**<br>**for OMD control unit**<br>||**Type**<br>||**Order number**|**Units/type**<br>**[pcs]**| |---|---|---|---| |OMD200_, OMD300_, OMD800_<br>|<br>~~___dia_(wLLLLlLllUE~~|OMZD1<br>|<br>~~___dia_(wLLLLlLllUE~~|1SCA022787R5190<br>~~___dia_(wLLLLlLllUE~~|1<br>~~___dia_(wLLLLlLllUE~~| OMZD1 ## Cover plate Providing protection against accidental contact. Padlockable transparent cover. The type and ordering codes are for 1 piece. |**Suitable**<br>**for OMD control unit**|**Type**|**Order number**|**Units/type**<br>**[pcs]**| |---|---|---|---| |OMD200_, OMD300_, OMD800_|OMZC2|1SCA101001R1001|1| OMZC2 Transfer, change-over and bypass switches | 1SCC303003C0201 | 99 ## Optional accessories for automatic transfer switches Ordering information for dual power sources ## Dual power source Provides power supply to the motor operator by using two lines. The device has two inputs, from line I (LN I) and line II (LN II), and one output for the motor operator. The motor operator is automatically energized whenever power is available in one of the lines. Can be used with 230VAC motor operators. Snap-on mounted PCB connectors are included in the delivery. The device can be DIN-rail or screw mounted. ODPSE230C **==> picture [384 x 155] intentionally omitted <==** **----- Start of picture text -----**<br> |||||| |---|---|---|---|---| |Suitable|Units/|Weight/| |for|type|unit| |switches|Type|Order number|[pcs]|[kg]| |OTM40…3200_|ODPSE230C|1SCA116892R1001|1|0.3| |Connection diagram, ODPSE230C|Line 1| |ODPS| |M| |Motor| |operator| |Line 2| |G| |oy©)|e| **----- End of picture text -----**<br> ## Dual power source including ATS functionality ODPS230 Similar to previous dual power source but also including ATS (Automatic Transfer Switch) functionality and in-built short-circuit protection. Provides power supply to the motor operator by using two 220...240 V AC lines. Motor operator is automatically energized whenever power is available in one of the lines. The device has a three position (AUTO-MAN-O) DIP switch to choose the correct operating mode. The AUTO position enables and the MAN position disables the ATS functionality when used with OTM motorized change-over switch. The O position is used for safety reasons: it operates the OTM to position 0 to isolate the load from the feeding sources. The device can be DIN-rail or screw mounted. **==> picture [383 x 161] intentionally omitted <==** **----- Start of picture text -----**<br> Suitable Units/ Weight/<br>for type unit<br>switches Type Order number [pcs] [kg]<br>OTM40...3200 ODPS230 1SCA122946R1001 1 0.3<br>Connection diagram, ODPS230<br>LN1 LN2<br>LL] L N ODPS230 LL L N OTM_<br>Motorized<br>change-over switch<br>N o o<br>Ut L N TTI C II I T 0 UU [Ted] PE N L [Tt] C II I 0 S07295<br>**----- End of picture text -----**<br> Connection diagram, ODPS230 Technical data and dimensional drawings to be found on the following pages. For further information on dual power sources please refer to page 74. 100 | 1SCC303003C0201 | Transfer, change-over and bypass switches ## Optional accessories for automatic transfer switches Technical data and dimensional drawings for dual power sources Technical data for dual power source ODPSE230C |**Dualpower source ODPSE230C**|| |---|---| |Rated operational voltage U[V]|220…240 V AC +/- 20%| |Rated frequency|50 / 60 Hz +/- 10%| |Short-circuitprotection device|Max. MCB 4 A| |Nominal output current I~~n~~ [A]|4 A| |~~n~~<br>Startuptime|Max. 1.0 s(with 230 V AC)| |Operatingtransfer time LN1 - LN2 or LN2 - LN1|Max. 0.5 s(with 230 V AC)| |Cable size|0,2…2,5 mm2| |Rated impulse withstand voltage,Uimp|4 kV| |Overvoltage category|III| |Pollution degree|3| |Protection ratingfor the frontpanel|IP20| |Operatingtemperature|– 25...+ 60 °C| |Transportation and storage temperature|– 40...+ 70 °C| |Altitude|Max. 2 000m| Technical data for new dual power source ODPS230 with ATS functionality |**Dualpower source ODPS230**|| |---|---| |Rated operational voltage U[V]|220…240 V AC,50 / 60 Hz| |Maximum voltage|288 V AC| |Pick-upvoltage|≥198 V AC| |Drop-out voltage|≤154 V AC| |Operatingtime|1 s ± 0.5 s| |Nominal output current I~~n~~ [A]|3,15 A| |~~n~~<br>Rated conditional short-circuit current,I~~p~~ (r.m.s.)|50 kA| |~~p~~<br>Internal fuse|T/3,15A/H*| |Fuse size|6,3 x 32 mm| |Rated impulse withstand voltage,U~~imp~~|4 kV| |~~imp~~<br>Overvoltage category|III| |Pollution degree|3| |Cable size|Max. 6 mm2| |Protection ratingfor the frontpanel|IP20| |Operatingtemperature|– 25...+ 60 °C| |Transportation and storage temperature|– 40...+ 70 °C| |Altitude|Max. 2 000m| *[)] The breaking capacity must be 50 kA to achieve 50 kA Ip (r.m.s.) rating Dimensional drawings for dual power sources ODPS230 ODPSE230C **==> picture [200 x 143] intentionally omitted <==** **----- Start of picture text -----**<br> mm<br>eee<br>Ø4,5<br>DIA 0,18<br>90<br>45 100<br>100<br>90<br>50<br>64<br>S07294<br>**----- End of picture text -----**<br> **==> picture [161 x 165] intentionally omitted <==** **----- Start of picture text -----**<br> a 32 52<br>ODPS<br>LN1 78<br>4 LN2<br>43<br>27,4<br>90 35,3<br>130<br>12X11<br>12X12<br>12X13<br>**----- End of picture text -----**<br> Transfer, change-over and bypass switches | 1SCC303003C0201 | 101 **==> picture [245 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> 102 | 1SCC303003C0201 | Transfer, change-over and bypass switches<br>**----- End of picture text -----**<br> ## Manual and motorized bypass switches Open transition from 160 to 800 Amperes **==> picture [258 x 283] intentionally omitted <==** **----- Start of picture text -----**<br> Introduction to manual and motorized bypass switches<br>General information 104<br>Product range 105<br>Type codes and functionality in brief 107<br>Technical data<br>OTM160...800_Y_ 108<br>Motor operators 109<br>Ordering information<br>Manual OT160…800E_YP 110<br>Motorized OTM160…800E_YM_C 112<br>Dimension drawings<br>Manual bypass switches 114<br>Motorized bypass switches 115<br>Ordering information for optional accessories<br>External handles and terminal shrouds 116<br>Phase barriers 117<br>Terminal clamps 118<br>Bridging- and reversing bars 119<br>Auxiliary contacts 120<br>**----- End of picture text -----**<br> ABB’s manual and motorized bypass switches are the best solution for optimized and efficient panel design. Transfer, change-over and bypass switches | 1SCC303003C0201 | 103 ## Manual and motorized bypass switches Optimized performance in a compact device Manual bypass switches shown above. Our comprehensive range of bypass switches from 160 to 800 Amperes is the best solution for an optimized and efficient panel design, for safe maintenance of critical components. Traditionally, bypass switches were built using individual switch-disconnectors connected with conversion kits. ABB offers a modern solution: one single device, consisting of three switches and no conversion kits. This does not only have a high performance, but optimizes space. ## Innovative space saving design Three switches are stacked on top of each other; so the total footprint is equivalent to only one switch. ABB’s bypass switches can be fitted into a smaller cabinet, compared to bypass switches built using conversion kits. This enables the customer to create more compact panels with an optimized design. Safe operation and maintenance ABB’s bypass switches fulfill isolating requirements according to standard IEC 60947-3, so there is no need for additional isolating devices. The equipment can be safely maintained while the load is being supplied directly from the source. 104 | 1SCC303003C0201 | Transfer, change-over and bypass switches ## Manual and motorized bypass switches Open transition from 160 to 800 Amperes Motorized bypass switches shown above. |**Manual operation, bypass switches, 160-800 A**|**Manual operation, bypass switches, 160-800 A**||| |---|---|---|---| |**Types**|OT160_Y|OT315_Y|OT630_Y| ||OT200_Y|OT400_Y|OT800_Y| ||OT250_Y||| |**lth /A**|**160**<br>**200**<br>**250**|**315**<br>**400**|**630**<br>**800**| |le/AC-22A, < 415V|160<br>200<br>250|315<br>400|630<br>800| |le/AC-23A, < 415V|160<br>200<br>250|315<br>400|630<br>800| |**Types**|OTM160_Y|OTM315_Y|OTM630_Y| |---|---|---|---| ||OTM200_Y|OTM400_Y|OTM800_Y| ||OTM250_Y||| |**lth /A**|**160**<br>**200**<br>**250**|**315**<br>**400**|**630**<br>**800**| |le/AC-22A, < 415V|160<br>200<br>250|315<br>400|630<br>800| |le/AC-23A, < 415V|160<br>200<br>250|315<br>400|630<br>800| Transfer, change-over and bypass switches | 1SCC303003C0201 | 105 ## Manual and motorized bypass switches Type codes and functionality in brief ## Type codes Understanding the type code keys below will help you quickly identify the correct product for your needs. The simple naming system allows you to see the products type, Ampere rating, standard classification and number of poles, all in one glance. |**Explanation of the manual bypass switces types OT160...3200_C**|**Explanation of the manual bypass switces types OT160...3200_C**|**Explanation of the manual bypass switces types OT160...3200_C**|**Explanation of the manual bypass switces types OT160...3200_C**|**Explanation of the manual bypass switces types OT160...3200_C**|**Explanation of the manual bypass switces types OT160...3200_C**| |---|---|---|---|---|---| |Option:<br>OT250<br>E<br>03<br>C<br>P|||||| |Position:|1|2|3|4|5| ||||||| |1<br>Brand and Switch size / Ampere rating|||||| |2<br>Standard|||||| |E: IEC|||||| |3<br>Number of thepoles|||||| |03: 12|||||| |04: 13|||||| |22: 33|||||| |4<br>Bypass switch|||||| |5<br>Included handle|||||| |P: Pistol handle + shaft|||||| |**Explanation of the motorized bypass switces types OTM160…2500_C**|**Explanation of the motorized bypass switces types OTM160…2500_C**|**Explanation of the motorized bypass switces types OTM160…2500_C**|**Explanation of the motorized bypass switces types OTM160…2500_C**|**Explanation of the motorized bypass switces types OTM160…2500_C**|**Explanation of the motorized bypass switces types OTM160…2500_C**| |---|---|---|---|---|---| |Option:<br>OTM250<br>E<br>3<br>Y<br>M<br>230C|||||| |Position:|1|2|3|4|5<br>5| ||||||| |1<br>Brand and Switch size / Ampere rating|||||| |2<br>IEC|||||| |E: IEC|||||| |3<br>Number of thepoles|||||| |3: 3-poles|||||| |4: 4-poles|||||| |4<br>Bypass switch|||||| |5<br>Motorized bypass switch|||||| |6<br>Voltage for motor operator|||||| |230C: 220...240 V AC|||||| ## Functionality in brief This simplified diagram illustrates the basic functionality and application of these switch products. **==> picture [287 x 88] intentionally omitted <==** **----- Start of picture text -----**<br> II<br>VFD O VFD VFD<br>I<br>M M M<br>**----- End of picture text -----**<br> 106 | 1SCC303003C0201 | Transfer, change-over and bypass switches Transfer, change-over and bypass switches | 1SCC303003C0201 | 107 ## Manual and motorized bypass switches Technical data for OT and OTM160...800_Y_ Manual and motorized bypass switches **==> picture [529 x 484] intentionally omitted <==** **----- Start of picture text -----**<br> Switch size , OTM_<br>Data according to IEC 60947-3 OTM160_ OTM200_ OTM250_ OTM315_ OTM400_ OTM630_ OTM800_<br>Rated insulation voltage and rated Pollution V 1000 1000 1000 1000 1000 1000 1000<br>operational voltage AC20/DC20 degree 3<br>Dielectric strength 50 Hz 1min. kV 10 10 10 10 10 10 10<br>Rated impulse withstand voltage kV 12 12 12 12 12 12 12<br>Rated thermal current and rated / ambient 40°C In open air A 160 200 250 315 400 630 800<br>operational current AC20/DC20 / ambient 40°C In enclosure A 160 200 250 315 400 630 800<br>..with minimum conductor cross section Cu mm [2] 70 95 120 185 240 2x185 2x240<br>Rated operational current, AC-21A up to 500 V A 160 200 250 315 400 630 800<br>690 V A 160 200 250 315 400 630 800<br>Rated operational current, AC-22A up to 500 V A 160 200 250 315 400 630 800<br> 690 V A 160 200 250 315 400 630 800<br>Rated operational current, AC-23A up to 415 V A 160 200 250 315 400 630 800<br>440 V A 160 200 250 315 400 630 800<br>500 V A 160 200 250 315 400 630 800<br>690 V A 160 200 250 315 400 630 800<br>Rated operational current / ≤ 110 V A 160/2 200/2 250/2 315/14) 400/14) 630/1 800/1<br>poles in series, DC-21A1) 220 V A 160/2 200/2 250/2 315/24) 400/24) 630/1 800/1<br>440 V A 160/3 200/3 230/3 315/3 360/3 630/2 720/2<br>660 V A 160/4 200/4 200/4 315/4 315/4 630/44) 630/44)<br>Rated operational power, AC-23A [2)] 230 V kW 45 60 75 100 132 200 250<br>The kW-ratings are accurate 400 V kW 90 110 140 160 220 355 450<br>for 3-phase 1500 R.P.M. standard 415 V kW 90 110 145 180 230 355 450<br>asychronous motors 500 V kW 110 132 170 220 280 400 560<br>690 V kW 160 200 250 315 400 630 800<br>Rated breaking capacity up to 415 V A 1 280 1 600 2 000 2 520 3 200 5 040 6 400<br>in category AC-23 500 V A 1 280 1 600 2 000 2 520 3 200 5 040 6 400<br>690 V A 1 280 1 600 2 000 2 520 3 200 5 040 6 400<br>Rated conditional short-circuit current Ip (r.m.s.) 80 kA, 415 V îc (peak) kA 40.5 40.5 40.5 59 59 83.5 83.5<br>Ip (r.m.s.) and cut-off current îc Max. OFA_ fuse size gG/aM A/A 355/315 355/315 355/315 500/500 500/500 800/1 000 800/1 000<br>(peak) value. The cut-off current îc Ip (r.m.s.) 100 kA, 500 V îc (peak) kA 40.5 40.5 40.5 61.5 61.5 90 90<br>refers to values listed by fuse<br>manufacturers (single phase test acc. to Max. OFA_ fuse size gG/aM A 315/315 315/315 315/315 500/450 500/450 800/800 800/800<br>IEC60269). Ip (r.m.s.) 80 kA, 690 V îc (peak) kA 40.5 40.5 40.5 59 59 83.5 83.5<br>Max. OFA_ fuse size gG/aM A 355/315 355/315 355/315 500/500 500/500 800/1 000 800/1 000<br>Rated short-time withstand current Icw (r.m.s.) 690 V 0.15s kA 15 15 15 31 31 38 38<br>690 V 0.25s kA 15 15 15 24 24 36 36<br>690 V 1s kA 8 8 8 15 15 20 20<br>Rated short-time making capacity3) Icm (peak)4) 690 V kA 30 30 30 65 65 80 80<br>Power loss / pole With rated current W 2.4 4 6.5 6.5 10 25 40<br>Mechanical endurance Number of oper. cycles [5)] Cycles 8 000 8 000 8 000 8 000 8 000 5 000 5 000<br>Terminal bolt size Metric thread mm M8x25 M8x25 M8x25 M10x30 M10x30 M12x40 M12x40<br>diameter x length<br>Terminal tightening torque Counter torque required Nm 15-22 15-22 15-22 30-44 30-44 50-75 50-75<br>Operating torque Typical for Nm 14 14 14 32 32 54 54<br>3-pole bypass switches<br>Weight without accessories Manual bypass switches 3-pole switch kg 4.3 4.3 4.3 8.2 8.2 19.9 19.9<br>4-pole switch kg 5.8 5.8 5.8 11.0 11.0 26.6 26.6<br>**----- End of picture text -----**<br> - 1) Further ratings on request 2) These values are given for guidance and may vary acc. to the motor manufacturer - 4) Max. distance from switch frame to nearest busbar / cable support 150 mm 5) Operating cycle: O - I - O - II - O 3) Short circuit duration > 50ms, without fuse protection 108 | 1SCC303003C0201 | Transfer, change-over and bypass switches ## Manual and motorized bypass switches Technical data for motor operators ## Motorized bypass switches, Motor operator **==> picture [525 x 326] intentionally omitted <==** **----- Start of picture text -----**<br> Switch size<br>Data according to IEC 60947 160…250 315...400 630…800<br>Rated operational voltage Ue Pollution degree 3 50/60 Hz V AC 220 - 240<br>Operating voltage range 0,85 - 1,1 x Ue<br>Operating time1) 90° I-0, 0-I, 0-II, II-0 220-240VAC s 0.4-1.0 0.4-1.0 0.4-1.0<br>Operating transfer time1) 180° I-0-II, II-0-I 220-240VAC s 1.0-2.0 0.9-2.0 0.9-2.0<br>OFF -time when operating I-II or II-I1) 180° I-II, II-I 220-240VAC s 0.4-1.0 0.4-1.0 0.4-1.0<br>Nominal current In1) 220-240VAC A 0.2 0.5 0.7<br>Current inrush1) 220-240VAC A 1.3 2.1 2.8<br>Overload fuse Type / In / Capacity 220-240VAC mA T/315/H T/500/H T/1 000/H<br>Operating rate Cycle 0-I-0-II-0, 220-240VAC cycles/min 1 1 1<br>Overvoltage category III<br>Rated impulse withstand voltage Uimp kV 4<br>Dielectric strength 50 Hz 1 min. kV 1.5<br>Impulse command Min. impulse<br>duration ms 100<br>Terminals<br>Voltage supply wiring for Ue PE - N - L<br>Cross section solid/stranded mm2 1.5 - 2.5<br>Short-circuit protection device max. MCB A C16<br>Control terminal (no SELV) C - II - I - O<br>Cross section solid/stranded mm2 1.5 - 2.5<br>Maximum cable length m 100<br>State information of locking (no SELV)<br>Handle attached or motor operator locked 11-12-14 (C/O) 5A/250V/cos ϕ =1<br>Locking motor operator 23-24 (NO) 5A/250V/cos ϕ =1<br>Short-circuit protection device Max. MCB A C2<br>Protection degree IP20<br>Operating temperature °C -25…+55<br>Transportation and storage temperature °C -40…+70<br>Max. altitude m 2 000<br>**----- End of picture text -----**<br> 1) Under nominal conditions Transfer, change-over and bypass switches | 1SCC303003C0201 | 109 ## Manual and motorized bypass switches Ordering information for OT160...800E03_Y **==> picture [221 x 314] intentionally omitted <==** **----- Start of picture text -----**<br> 5<br>5<br>3<br>8<br>iaR : |<br>4<br>cel 2 re.<br>oO a = ==<br>6<br>©) 1 2<br>**----- End of picture text -----**<br> 7 ## Bypass switches accessory guide 1. Manual bypass switch 5. Terminal shroud 2. Extended shaft 3. Terminal clamp 4. Auxiliary contact 6. Pistol handle 7. Handle extension 8. Bridging bar Please note that not all listed accessories are automatically included in your order. See next page for recommendations. 110 | 1SCC303003C0201 | Transfer, change-over and bypass switches ## Manual and motorized bypass switches Ordering information for manual OT160…800_Y ## Manual bypass switches, OT160…800_Y OT160...250E03_YP Delivered with a black plastic IP65 I-0-II pistol handle and a handle extension for enabling smooth manual operation, shaft and bolt set for the cable connection. The handle extension is snap-onmounted on the standard handle for manual operation. The handle extension shall be removed when padlocking the standard handle. Handle padlockable in the 0-position, door interlock in the I- and II-positions and when padlocked. ## Open transition OT315...400E03_YP OT630...800E03_YP |**No.**<br>**of**<br>**poles**|**Rated current and power**|**Rated current and power**|**Rated current and power**|**Type**|**Order number**|**Weight/**<br>**unit**<br>**[kg]**| |---|---|---|---|---|---|---| ||**AC-21A/AC-22A**||**AC-23A**|||| ||**≤ 415V**<br>**I[A]**|**400V**<br>**S[kVA]**|**400...415V**<br>**I[A]/P[kW]**|||| |3|160|110|160/90|OT160E03YP|1SCA123551R1001|5.6| |4|160|110|160/90|OT160E04YP|1SCA123556R1001|7.5| |3|200|135|200/110|OT200E03YP|1SCA123552R1001|5.6| |4|200|135|200/110|OT200E04YP|1SCA123557R1001|7.5| |3|250|170|250/140|OT250E03YP|1SCA123553R1001|5.6| |4|250|170|250/140|OT250E04YP|1SCA123558R1001|7.5| |3|400|275|400/220|OT400E03YP|1SCA123582R1001|10.1| |4|400|275|400/220|OT400E04YP|1SCA124026R1001|13.5| |3|630|435|630/355|OT630E03YP|1SCA123590R1001|| |4|630|435|630/355|OT630E04YP|1SCA123592R1001|| |3|800|550|800/450|OT800E03YP|1SCA123591R1001|| |4|800|550|800/450|OT800E04YP|1SCA123593R1001|| ## Closed transition **==> picture [39 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> OHBZX200<br>**----- End of picture text -----**<br> **==> picture [39 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> OHBZX275<br>**----- End of picture text -----**<br> |**No.**<br>**of**<br>**poles**|**Rated current and power**|**Rated current and power**|**Rated current and power**|**Type**|**Order number**|**Weight/**<br>**unit**<br>**[kg]**| |---|---|---|---|---|---|---| ||**AC-21A/AC-22A**||**AC-23A**|||| ||**≤ 415V**<br>**I[A]**|**400V**<br>**S[kVA]**|**400...415V**<br>**I[A]/P[kW]**|||| |3|160|110|160/90|OT160E03YLP|1SCA145895R1001|5.6| |4|160|110|160/90|OT160E04YLP|1SCA145907R1001|7.5| |3|200|135|200/110|OT200E03YLP|1SCA145896R1001|5.6| |4|200|135|200/110|OT200E04YLP|1SCA145908R1001|7.5| |3|250|170|250/140|OT250E03YLP|1SCA145897R1001|5.6| |4|250|170|250/140|OT250E04YLP|1SCA145909R1001|7.5| |3|400|275|400/220|OT400E03YLP|1SCA145932R1001|10.1| |4|400|275|400/220|OT400E04YLP|1SCA145938R1001|13.5| |3|630|435|630/355|OT630E03YLP|1SCA145954R1001|| |4|630|435|630/355|OT630E04YLP|1SCA145960R1001|| |3|800|550|800/450|OT800E03YLP|1SCA145955R1001|| |4|800|550|800/450|OT800E04YLP|1SCA145961R1001|| Shafts, handle, handle extension and bolt kits included as standard |**Suitable for switches**|**Shaft**|**Handle**|**Handle extension**|**Bolt kit**| |---|---|---|---|---| |OT160...250_Y|OXP6/12x161C|OHB65J12E011|OHBZX200|M8x25| |OT315...400_Y|OXP12x166|OHB95J12E011|OHBZX200|M10x30| |OT630...800_Y|OXP12x185|OHB125J12E011|OHBZX275|M12x40| Transfer, change-over and bypass switches | 1SCC303003C0201 | 111 Manual and motorized bypass switches Ordering information for OTM160...800E_YM_C **==> picture [96 x 21] intentionally omitted <==** **----- Start of picture text -----**<br> 5<br>5<br>**----- End of picture text -----**<br> **==> picture [96 x 30] intentionally omitted <==** **----- Start of picture text -----**<br> 2<br>7<br>**----- End of picture text -----**<br> **==> picture [8 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> 3<br>**----- End of picture text -----**<br> **==> picture [9 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> 4<br>**----- End of picture text -----**<br> 6 1 O) di | ## Bypass switches accessory guide 1. Manual bypass switch 2. Terminal clamp 3. Auxiliary contact 5. Terminal shroud 6. Handle extension 7. Voltage sensing connector 4. Storage for handle and fuses Please note that not all listed accessories are automatically included in your order. See next page for recommendations. 112 | 1SCC303003C0201 | Transfer, change-over and bypass switches ## Manual and motorized bypass switches Ordering information for motorized OTM160…800E_YM_C Motorized bypass switches, open transition, OTM160…800E_YM_C Included a manual direct handle, bolt set for the cable connection and storage clip for handle and spare fuses. Handle padlockable in the 0-position. OTM160...250E3YM230C OTM315...400E3YM230C OTM315...400E4YM230C |3|160|110|160/90|OTM160E3YM230C|1SCA141435R1001|7.72| |---|---|---|---|---|---|---| |4|160|110|160/90|OTM160E4YM230C|1SCA141436R1001|8.1| |3|200|135|200/110|OTM200E3YM230C|1SCA141437R1001|7.72| |4|200|135|200/110|OTM200E4YM230C|1SCA141438R1001|8.1| |3|250|170|250/140|OTM250E3YM230C|1SCA141439R1001|7.72| |4|250|170|250/140|OTM250E4YM230C|1SCA140870R1001|8.1| |3|315|215|315/160|OTM315E3YM230C|1SCA141440R1001|14| |4|315|215|315/160|OTM315E4YM230C|1SCA141441R1001|16| |3|400|275|400/220|OTM400E3YM230C|1SCA136735R1001|14| |4|400|275|400/220|OTM400E4YM230C|1SCA136677R1001|16| |3|630|435|630/355|OTM630E3YM230C|1SCA136615R1001|25.9| |4|630|435|630/355|OTM630E4YM230C|1SCA136613R1001|28.5| |3|800|550|800/450|OTM800E3YM230C|1SCA136616R1001|25.9| |4|800|550|800/450|OTM800E4YM230C|1SCA136614R1001|28.5| OTM630-800E3YM230C ## Recommended accessories: Bridging bars Please note that two sets of bridging bars are required to make a complete connection. OTM630-800E4YM230C |**Suitable**<br>**for**<br>**switches**|**No.**<br>**of**<br>**poles**|**Type**|**Order number**|**Units/**<br>**type**<br>**[pcs]**|**Weight/**<br>**unit**<br>**[kg]**| |---|---|---|---|---|---| |OT_160…250_C, _Y|3|OTZC13|1SCA022767R6910|3|0.6| |OT_160…250_C, _Y|4|OTZC14|1SCA022767R7040|4|0.8| |OT_315…400_C, _Y|3|OTZC23|1SCA022767R7120|3|0.6| |OT_315…400_C, _Y|4|OTZC24|1SCA022767R7210|4|0.8| |OT_600_C…800E_C, _Y|3|OTZC33|1SCA022785R7020|3|1.0| |OT_600_C…800E_C, _Y|4|OTZC34|1SCA022785R7110|4|1.3| OTZC13 ## Recommended accessories: Phase barriers OTZC23 |**Suitable**<br>**for**<br>**switches**|**No.**<br>**of**<br>**poles**|**Height**<br>**h**<br>**[mm]**|**Cutting**<br>**width W**<br>**of the**<br>**phase**<br>**barrier**<br>**[mm]**|**Type**|**Order number**|**Units/**<br>**type**<br>**[pcs]**| |---|---|---|---|---|---|---| |OT_160…250E_C|3|100|55|PB100 low|1SDA054970R1|4| |OT_160…250E_C|3|200|55|PB200 high|1SDA054972R1|4| |OT_160…250E_C|4|100|55|PB100 low|1SDA054971R1|6| |OT_160…250E_C|4|200|55|PB200 high|1SDA054973R1|6| |OT_315…400E_C|3|100|67|PB100 low|1SDA054970R1|4| |OT_315…400E_C|3|200|67|PB200 high|1SDA054972R1|4| Transfer, change-over and bypass switches | 1SCC303003C0201 | 113 Manual and motorized bypass switches Dimensional drawings for manual bypass switches OT160...250E03/04Y |OT160...250_Y_|OT160...250_Y_|| |---|---|---| ||**E03**|**E04**| |A|35|35| |A1|118|118| |A2|172|207| |B|194|229| M00405 / OT160-250E02-04Y A **==> picture [352 x 145] intentionally omitted <==** **----- Start of picture text -----**<br> A2 236<br>44,533,5 20 52,5 75 3 75 11,5 83/35,5 200<br>25<br>6/12<br>A1 93,5 130<br>138 100 122 150<br>65<br> 14 min<br>68,5 A A 33,5 58,5<br>B 330...370 45<br>(OXP 6/12x161C)<br>Ø 9<br>Y A /ES<br>**----- End of picture text -----**<br> OT315…400E03/04Y |OT315...400E_Y|OT315...400E_Y|| |---|---|---| ||**E03**|**E04**| |A|44|44| |A1|136|136| |A2|218|262| |B|240|284| M00409 / OT315-400E02-04Y B/E OT630…800E03/04Y ||**E03**|**E04**| |---|---|---| |A|**E03**<br>65|**E04**<br>65| |A1<br>A2|180<br>294|180<br>359| **==> picture [70 x 4] intentionally omitted <==** **----- Start of picture text -----**<br> M00397 / OT630-800E02-04Y B /ES<br>**----- End of picture text -----**<br> **==> picture [349 x 364] intentionally omitted <==** **----- Start of picture text -----**<br> A2 305,5<br>285<br>4<br>43 25 58 87 87 20,5 83/35,5 200<br>32,5<br>12<br>156 150 185<br>A1 160<br>95<br>20 min<br>A 39 86<br>B (OXP 12 x 166)364...428 45<br>432<br>A2<br>407<br>49,5 13,5 39 78,1 132,6 138,6<br>275<br>61,5<br>45<br>12<br>200 160 ON 198 250<br>A1 OFF<br>ON 210<br>25 125<br>50 min.<br>17<br>27,5<br>114,5 A 49,5 105 45<br>B 488...573<br>(OXB 12x185)<br>Ø 11<br>120<br>**----- End of picture text -----**<br> 114 | 1SCC303003C0201 | Transfer, change-over and bypass switches Manual and motorized bypass switches Dimensional drawings motorized bypass switches **==> picture [492 x 336] intentionally omitted <==** **----- Start of picture text -----**<br> OT160...250E03-04Y 161236<br>A2 66<br>65<br>OTM160...250_Y 20 83 3<br>[mm/ln] E2 E3 E4 25 125<br>A 35 35 35<br>A1 118 118 118 138 100 122 150 14<br>A2 239 274 309 A1 130 65<br>ee sa i | P<br>B 251 296 331<br>20<br>M00339 / OTM160-250E2-4Y A 135,5 37<br>170,5 foo A A 33,5 52,5 75 c= 75<br>B<br>OTM315...400E_Y 145 A2 95 58 87 87 81<br>4<br>11 25 200<br>OTM315–400E_Y 32,5 126<br>[mm/ln] E2 E3 E4<br>A 44 44 44 150 185<br>A1 17<br>A1 136 136 136 160<br>156 120<br>A2 276 320 364<br>B 298 342 386 95<br>M00401 / OTM315-400E_Y A 20,5<br>193 A 39 285 43<br>B<br>**----- End of picture text -----**<br> **==> picture [492 x 147] intentionally omitted <==** **----- Start of picture text -----**<br> 450<br>OTM630...800E_Y 407<br>A2 110,5 132,6<br>OTM630–800E_Y [mm/ln] E2 E3 E4 149,5 13,5 39 7 8, 1 138,6 5 275<br>A 65 65 65 45<br>A1 180 180 180 250<br>A2 329 394 459 200A1160 ManM . 198210 17<br>B 350 415 480<br>145<br>M00404 / OTM630-800E2_4Y A<br>17 20,5<br>27,5<br>214,5 A 49,5 42,5<br>B<br>A<br>**----- End of picture text -----**<br> Transfer, change-over and bypass switches | 1SCC303003C0201 | 115 ## Optional accessories for manual and motorized bypass switches Ordering information for external handles ## Handle extension for bypass switches, plastic OHBZX200 The handle extension is snap-on mounted on the standard handle for manual operation. The handle extension shall be removed when padlocking the standard handle. Units / type = 1 pcs. OHBZX275 |**Colour**|**Type**|**Order number**|**Delivery**<br>**batch**<br>**[pcs]**| |---|---|---|---| |Black|OHBZX200|1SCA125960R1001|1| |Black|OHBZX275|1SCA125963R1001|1| ## Ordering information for terminal shrouds ## Terminal shrouds, grey plastic Snap-on mounting to the switches, IP 20. A kit includes three or four shrouds which can be used on either side of the switch. Suitable for the upperswitch. Transparent shrouds for OT_160…2500 available on request, please replace the letter “G” with “T”. OTS_L_ OTS_S_ |**Suitable**<br>**for**<br>**switches**|**No.**<br>**of**<br>**poles**|**Description**|**Type**|**Order number**|**Units/**<br>**type**<br>**[pcs]**|**Weight/**<br>**unit**<br>**[kg]**| |---|---|---|---|---|---|---| |OT_160…250_Y|3|Long type|OTS250G1L/3|1SCA022731R8150|3|0.09| |OT_160…250_Y|3|Short type|OTS250G1S/3|1SCA022731R8310|3|0.06| |OT_160…250_Y|4|Long type|OTS250G1L/4|1SCA022731R8230|4|0.12| |OT_160…250_Y|4|Short type|OTS250G1S/4|1SCA022731R8400|4|0.08| |OT_315…400_Y|3|Long type|OTS400G1L/3|1SCA022736R8840|3|0.15| |OT_315…400_Y|3|Short type|OTS400G1S/3|1SCA022736R9060|3|0.09| |OT_315…400_Y|4|Long type|OTS400G1L/4|1SCA022736R9490|4|0.20| |OT_315…400_Y|4|Short type|OTS400G1S/4|1SCA022736R9650|4|0.12| |OT_600…800_Y|3|Long type|OTS800G1L/3|1SCA022776R7890|3|0.32| |OT_600…800_Y|3|Short type|OTS800G1S/3|1SCA022776R8190|3|0.17| |OT_600…800_Y|4|Long type|OTS800G1L/4|1SCA022776R7970|4|0.42| |OT_600…800_Y|4|Short type|OTS800G1S/4|1SCA022776R8270|4|0.26| 116 | 1SCC303003C0201 | Transfer, change-over and bypass switches ## Optional accessories for manual and motorized bypass switches Ordering information for phase barriers ## Phase barriers The phase barriers designed for ABB Tmax T4-T5 MCCB’s can also be used for OT_160...800 change-over switches. 3-pole change-overs need 8 barriers and 4-pole change-overs need 12 barriers for full protection. PB_ |**No.**<br>**of**<br>**poles**|**Height**<br>**h**<br>**[mm]**|**Cutting**<br>**width W**<br>**of the**<br>**phase**<br>**barrier**<br>**[mm]**|**Type**|**Order number**| |---|---|---|---|---| |3|100|55|PB100 low|1SDA054970R1| |3|200|55|PB200 high|1SDA054972R1| |4|100|55|PB100 low|1SDA054971R1| |4|200|55|PB200 high|1SDA054973R1| |3|100|67|PB100 low|1SDA054970R1| |3|200|67|PB200 high|1SDA054972R1| |4|100|67|PB100 low|1SDA054971R1| |4|200|67|PB200 high|1SDA054973R1| |3|100|90|PB100 low|1SDA054970R1| |3|200|90|PB200 high|1SDA054972R1| |4|100|90|PB100 low|1SDA054971R1| |4|200|90|PB200 high|1SDA054973R1| Transfer, change-over and bypass switches | 1SCC303003C0201 | 117 ## Optional accessories for manual and motorized bypass switches Ordering information for terminal clamps OZXB2L OZXB7L OZXB9 |**Suitable**<br>**for**<br>**switches**<br>~~ne~~|**Cable cross**<br>**section**<br>**[mm2]**|**Suitable**<br>**shroud**|**Type **|**Order number**|**Units/**<br>**type**<br>**[pcs]**|**Delivery**<br>**batch**<br>**[pcs]**|**Weight/**<br>**unit**<br>**[kg]**| |---|---|---|---|---|---|---|---| |OT100…125F_|10...70||OZXL1|1SCA022439R6770|3|1|0.14| |OTM40...125F_|10...70||OZXL1|1SCA022439R6770|3|1|0.14| |OT_160...250E_C, _Y|10...70|OTS250_L|OZXB1L|1SCA022169R2030|3|1|0.15| |OT_160...250E_C, _Y|10...70|OTS250_L|OZXB1L/1|1SCA022194R0030|1|50|0.05| |OT_160...250E_C, _Y|25...120|OZXB2K|OZXB2|1SCA022119R7610|3|1|0.34| |OT_160...250E_C, _Y|25...120|OZXB2K|OZXB2/1|1SCA022194R0200|1|50|0.12| |OT_160...250E_C, _Y|25...120|OZXB2K|OZXB2L|1SCA022158R7750|3|1|0.43| |OT_160...250E_C, _Y|25...120|OZXB2K|OZXB2L/1|1SCA022194R0460|1|50|0.15| |OT_160...250E_C, _Y|95...185|OTS250_L|OZXB8|1SCA022744R1510|3|1|0.50| |OT_160...250E_C, _Y|95...185|OTS250_L|OZXB8/1|1SCA022744R1600|1|20|0.15| |OT_160...250E_C, _Y|95...240|OTS250_L|OZXB9|1SCA022750R3210|3|1|0.50| |OT_160...250E_C, _Y|95...240|OTS250_L|OZXB9/1|1SCA022750R3300|1|20|0.15| |OT_315...400E_C, _Y|25...120|OZXB2K|OZXB2L|1SCA022158R7750|3|1|0.43| |OT_315...400E_C, _Y|25...120|OZXB2K|OZXB2L/1|1SCA022194R0460|1|50|0.15| |OT_315...400E_C, _Y|70…185|OZXB3K|OZXB3|1SCA022136R8100|3|1|1.28| |OT_315...400E_C, _Y|70…185|OZXB3K|OZXB3/1|1SCA022194R0620|1|20|0.43| |OT_315...400E_C, _Y|2x(70…185)|OZXB3K|OZXB4|1SCA022137R4760|3|1|1.71| |OT_315...400E_C, _Y|2x(70…185)|OZXB3K|OZXB4/1|1SCA022194R0890|1|20|0.57| |OT_315...400E_C, _Y|120...240|OZXB5K|OZXB7|1SCA022185R0040|3|1|1.00| |OT_315...400E_C, _Y|120...240|OZXB5K|OZXB7/1|1SCA022194R1430|1|20|0.34| |OT_315...400E_C, _Y|120...240|OZXB5K|OZXB7L|1SCA022185R7130|3|1|1.17| |OT_315...400E_C, _Y|120...240|OZXB5K|OZXB7L/1|1SCA022194R1600|1|20|0.40| |OT_315...400E_C, _Y|95...185|OTS400_L|OZXB8|1SCA022744R1510|3|1|0.50| |OT_315...400E_C, _Y|95...185|OTS400_L|OZXB8/1|1SCA022744R1600|1|20|0.15| |OT_315...400E_C, _Y|95...240|OTS400_L|OZXB9|1SCA022750R3210|3|1|0.50| |OT_315...400E_C, _Y|95...240|OTS400_L|OZXB9/1|1SCA022750R3300|1|20|0.15| 118 | 1SCC303003C0201 | Transfer, change-over and bypass switches ## Optional accessories for manual and motorized bypass switches Ordering information for bridging- and reversing bars ## Bridging bars The bridging bars provide a connection link either on the incoming or outcoming side of the switch. Please note that two sets of bridging bars are required to make a complete connection. OTZC13...34 |**No.**<br>**of**<br>**poles**|**Type**|**Order number**|**Units/**<br>**type**<br>**[pcs]**| |---|---|---|---| |3|OTZC13|1SCA022767R6910|3| |4|OTZC14|1SCA022767R7040|4| |3|OTZC23|1SCA022767R7120|3| |4|OTZC24|1SCA022767R7210|4| |3|OTZC33|1SCA022785R7020|3| |4|OTZC34|1SCA022785R7110|4| ## Reversing bars A reversing switch can be built by using phase sequence bars in two phases. The kit includes two phase sequence conversion bars. The missing bridging bars must be ordered separately, see above. For example 3-pole switches: one 4-pole standard bridging bar kit is required (one bar for the reversing side, three bars for the other side). OTZR_ |**Suitable**<br>**for**<br>**switches**|**Type**|**Order number**|**Units/**<br>**type**<br>**[pcs]**|**Weight/**<br>**unit**<br>**[kg]**| |---|---|---|---|---| |OT_160…250_C|OTZR1|1SCA100352R1001|2|0.3| |OT_315…400_C|OTZR2|1SCA104647R1001|2|0.3| |OT_600_C…800E_C|OTZR3|1SCA100355R1001|2|0.4| Transfer, change-over and bypass switches | 1SCC303003C0201 | 119 Optional accessories for manual and motorized bypass switches Ordering information and technical data for auxiliary contacts ## Auxiliary contact blocks for OT_160...800 Mounting on the right side of the switch: Max. 4 auxiliary contact blocks/switch (totally 8 blocks). Types _AU have gold plated contacts for harsh environments and low operating voltages. Simultaneous action with the main contacts, IP20. The type and ordering numbers are for one piece. **OA1G01 OA7G10** |**Contact**<br>**functions**|**Installation**<br>**side**|**Type**|**Order number**|**Delivery**<br>**batch**<br>**[pcs]**| |---|---|---|---|---| |1NO|Right|OA1G10|1SCA022353R4970|10| |1NC|Right|OA3G01|1SCA022456R7410|10| |1NO|Right|OA1G10AU|1SCA022436R7910|10| |1NC|Right|OA3G01AU|1SCA022819R5260|10| ## Auxiliary contacts **OA1G10 OA8G01** **Technical data for auxiliary contacts according to IEC 60947-5-1, for OA1G_, OA2G_, OA3G_, OA7G_, OA8G_** |**AC15**|**AC15**|**AC15**|**DC12**|**DC12**|**DC13**|**DC13**| |---|---|---|---|---|---|---| |**Ue/[V]**|**Ie/[A]**|**Ue/[V]**|**Ie/[A]**|**P/[W]**|**Ie/[A]**|**P/[W]**| |230|6|24|10|240|2|50| |400|4|72|4|290|0.8|60| |415|4|125|2|250|0.55|70| |690|2|250|0.55|140|0.27|70| |||440|0.1|44||| ## Function tables ## **Function table of OT160…3200, OT160...800_Y and OTM160…2500 auxiliary contacts / Switch I (max. 2+2)** **==> picture [29 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> OA2G11<br>**----- End of picture text -----**<br> |**Handleposition**|**Main contacts**||**OA1G10 NO**|**OA3G01 NC**| |---|---|---|---|---| |I|closed||closed|open| |0|open||open|closed| |II|closed||open|closed| |**Function table of OT160…3200, OT160...800_Y and OTM160…2500 auxiliary contacts / Switch II (max. 2+2)**||||| |**Handleposition**|**Main contacts**||**OA1G10 NO**|**OA3G01 NC**| |I|closed||open|closed| |0|open||open|closed| |II|closed||closed|open| 120 | 1SCC303003C0201 | Transfer, change-over and bypass switches Transfer, change-over and bypass switches | 1SCC303003C0201 | 121 ## Transfer, change-over and bypass switches Index **==> picture [528 x 634] intentionally omitted <==** **----- Start of picture text -----**<br> Description Type Order number Page Description Type Order number Page<br>Automatic control units OMD200E480C-A1 1SCA123789R1001 72 Automatic transfer switches, OTM800E4C8D230C 1SCA108455R1001 89<br>OMD300E480C-A1 1SCA123790R1001 72 open transition OTM1000E3C8D230C 1SCA112868R1001 89<br>OMD800E480C-A1 1SCA123791R1001 72 OTM1000E4C8D230C 1SCA112861R1001 89<br>OMD200E480C-A1 1SCA123789R1001 99 OTM1250E3C8D230C 1SCA112862R1001 89<br>OMD300E480C-A1 1SCA123790R1001 99 OTM1250E4C8D230C 1SCA112864R1001 89<br>OMD800E480C-A1 1SCA123791R1001 99 OTM1600E3C8D230C 1SCA112866R1001 89<br>Automatic transfer switches, OTM160E4C2D230C 1SCA106230R1001 88 OTM1600E4C8D230C 1SCA112867R1001 89<br>open transition OTM160E4WC2D230C 1SCA101033R1001 88 Auxiliary contact blocks OA1G10 1SCA022353R4970 43<br>OTM200E4C2D230C 1SCA106671R1001 88 OA8G01 1SCA022744R2240 43<br>OTM200E4WC2D230C 1SCA101034R1001 88 OA7G10 1SCA022673R1140 43<br>OTM250E4WC2D230C 1SCA101035R1001 88 OA1G01 1SCA022353R4890 43<br>OTM315E4C2D230C 1SCA101059R1001 88 OA2G11 1SCA022379R8100 43<br>OTM400E4C2D230C 1SCA101060R1001 88 OA1G10 1SCA022353R4970 43<br>OTM630E4C2D230C 1SCA108434R1001 88 OA3G01 1SCA022456R7410 43<br>OTM800E4C2D230C 1SCA108439R1001 88 OA1G10AU 1SCA022436R7910 43<br>OTM1000E4C2D230C 1SCA112858R1001 88 OA3G01AU 1SCA022819R5260 43<br>OTM1250E4C2D230C 1SCA112857R1001 88 OA1G10 1SCA022353R4970 71<br>OTM1600E4C2D230C 1SCA112854R1001 88 OA8G01 1SCA022744R2240 71<br>OTM160E4C3D230C 1SCA106305R1001 88 OA7G10 1SCA022673R1140 71<br>OTM160E4WC3D230C 1SCA106306R1001 88 OA1G01 1SCA022353R4890 71<br>OTM200E4C3D230C 1SCA106309R1001 88 OA2G11 1SCA022379R8100 71<br>OTM200E4WC3D230C 1SCA106310R1001 88 OA1G10 1SCA022353R4970 71<br>OTM250E4C3D230C 1SCA106313R1001 88 OA3G01 1SCA022456R7410 71<br>OTM250E4WC3D230C 1SCA106314R1001 88 OA1G10AU 1SCA022436R7910 71<br>OTM315E4C3D230C 1SCA106317R1001 88 OA3G01AU 1SCA022819R5260 71<br>OTM400E4C3D230C 1SCA106318R1001 88 OA1G10 1SCA022353R4970 98<br>OTM630E4C3D230C 1SCA108726R1001 88 OA8G01 1SCA022744R2240 98<br>OTM800E4C3D230C 1SCA108728R1001 88 OA7G10 1SCA022673R1140 98<br>OTM1000E4C3D230C 1SCA112852R1001 88 OA1G01 1SCA022353R4890 98<br>OTM1250E4C3D230C 1SCA112851R1001 88 OA2G111) 1SCA022379R8100 98<br>OTM1600E4C3D230C 1SCA112848R1001 88 OA1G10 1SCA022353R4970 98<br>OTM160E3C8D230C 1SCA101017R1001 89 OA3G01 1SCA022456R7410 98<br>OTM160E3WC8D230C 1SCA101036R1001 89 OA1G10AU 1SCA022436R7910 98<br>OTM160E4C8D230C 1SCA101020R1001 89 OA3G01AU 1SCA022819R5260 98<br>OTM160E4WC8D230C 1SCA101039R1001 89 OA1G10 1SCA022353R4970 120<br>OTM200E3C8D230C 1SCA101018R1001 89 OA3G01 1SCA022456R7410 120<br>OTM200E3WC8D230C 1SCA101037R1001 89 OA1G10AU 1SCA022436R7910 120<br>OTM200E4C8D230C 1SCA101021R1001 89 OA3G01AU 1SCA022819R5260 120<br>OTM200E4WC8D230C 1SCA101040R1001 89 Bridging bars OTZC13 1SCA022767R6910 42<br>OTM250E3C8D230C 1SCA101019R1001 89 OTZC14 1SCA022767R7040 42<br>OTM250E3WC8D230C 1SCA101038R1001 89 OTZC23 1SCA022767R7120 42<br>OTM250E4C8D230C 1SCA101022R1001 89 OTZC24 1SCA022767R7210 42<br>OTM250E4WC8D230C 1SCA101041R1001 89 OTZC33 1SCA022785R7020 42<br>OTM315E3C8D230C 1SCA101062R1001 89 OTZC34 1SCA022785R7110 42<br>OTM315E4C8D230C 1SCA101063R1001 89 OTZC43 1SCA022868R0710 42<br>OTM400E3C8D230C 1SCA101061R1001 89 OTZC44 1SCA022868R0800 42<br>OTM400E4C8D230C 1SCA101064R1001 89 OTZC53 1SCA022868R0980 42<br>OTM630E3C8D230C 1SCA108452R1001 89 OTZC54 1SCA022868R1010 42<br>OTM630E4C8D230C 1SCA108453R1001 89 OTZC63 1SCA022868R1100 42<br>OTM800E3C8D230C 1SCA108454R1001 89 OTZC64 1SCA022868R1360 42<br>**----- End of picture text -----**<br> 122 | 1SCC303003C0201 | Transfer, change-over and bypass switches ## Transfer, change-over and bypass switches Index **==> picture [527 x 659] intentionally omitted <==** **----- Start of picture text -----**<br> Description Type Order number Page Description Type Order number Page<br>Bridging bars OTZC73 1SCA128843R1001 42 Handle and spare fuse OTVS0 1SCA117524R1001 66<br>OTZC74 1SCA128844R1001 42 storage clip OTVS1 1SCA111413R1001 66<br>OTZC13 1SCA022767R6910 69 OTVS2 1SCA111414R1001 66<br>OTZC14 1SCA022767R7040 69 Handle extension OHBZX200 1SCA125960R1001 116<br>OTZC23 1SCA022767R7120 69 for bypass switches OHBZX275 1SCA125963R1001 116<br>OTZC24 1SCA022767R7210 69 Handle knobs, non-padlockable OHBS3/1 1SCA108319R1001 34<br>OTZC33 1SCA022785R7020 69 OHBS3 1SCA108320R1001 34<br>OTZC34 1SCA022785R7110 69 OHRS3/1 1SCA108688R1001 34<br>OTZC43 1SCA022868R0710 69 OHRS3 1SCA108667R1001 34<br>OTZC44 1SCA022868R0800 69 OHBS9/1 1SCA108689R1001 34<br>OTZC53 1SCA022868R0980 69 OHBS9 1SCA108665R1001 34<br>OTZC54 1SCA022868R1010 69 OHRS9/1 1SCA108690R1001 34<br>OTZC63 1SCA022868R1100 69 OHRS9 1SCA108666R1001 34<br>OTZC64 1SCA022868R1360 69 Handle knobs, padlockable OHBS2/1 1SCA109090R1001 34<br>OTZC73 1SCA128843R1001 69 OHBS2 1SCA109089R1001 34<br>OTZC74 1SCA128844R1001 69 OHRS2/1 1SCA108599R1001 34<br>OTZC13 1SCA022767R6910 97 OHRS2 1SCA108598R1001 34<br>OTZC14 1SCA022767R7040 97 OHBS12/1 1SCA109094R1001 34<br>OTZC23 1SCA022767R7120 97 OHBS12 1SCA108252R1001 34<br>OTZC24 1SCA022767R7210 97 OHRS12/1 1SCA109097R1001 34<br>OTZC33 1SCA022785R7020 97 OHRS12 1SCA108253R1001 34<br>OTZC34 1SCA022785R7110 97 OHBS11/1 1SCA109093R1001 34<br>OTZC43 1SCA022868R0710 97 OHBS11 1SCA109092R1001 34<br>OTZC44 1SCA022868R0800 97 Manual bypass switches, OT160E03YP 1SCA123551R1001 111<br>OTZC53 1SCA022868R0980 97 open transition OT160E04YP 1SCA123556R1001 111<br>OTZC54 1SCA022868R1010 97 OT200E03YP 1SCA123552R1001 111<br>OTZC63 1SCA022868R1100 97 OT200E04YP 1SCA123557R1001 111<br>OTZC64 1SCA022868R1360 97 OT250E03YP 1SCA123553R1001 111<br>OTZC73 1SCA128843R1001 97 OT250E04YP 1SCA123558R1001 111<br>OTZC74 1SCA128844R1001 97 OT315E03YP 1SCA123581R1001 111<br>OTZC13 1SCA022767R6910 113 OT315E04YP 1SCA123583R1001 111<br>OTZC14 1SCA022767R7040 113 OT400E03YP 1SCA123582R1001 111<br>OTZC23 1SCA022767R7120 113 OT400E04YP 1SCA124026R1001 111<br>OTZC24 1SCA022767R7210 113 OT630E03YP 1SCA123590R1001 111<br>OTZC33 1SCA022785R7020 113 OT630E04YP 1SCA123592R1001 111<br>OTZC34 1SCA022785R7110 113 OT800E03YP 1SCA123591R1001 111<br>OTZC13 1SCA022767R6910 119 OT800E04YP 1SCA123593R1001 111<br>OTZC14 1SCA022767R7040 119 Manual change-over switches, OT160E03CLP 1SCA108468R1001 26<br>closed transition<br>OTZC23 1SCA022767R7120 119 OT160E03WCLP 1SCA108486R1001 26<br>OTZC24 1SCA022767R7210 119 OT160E04CLP 1SCA108491R1001 26<br>OTZC33 1SCA022785R7020 119 OT160E04WCLP 1SCA108494R1001 26<br>OTZC34 1SCA022785R7110 119 OT200E03CLP 1SCA108522R1001 26<br>Cover plate OMZC2 1SCA101001R1001 72 OT200E03WCLP 1SCA108525R1001 26<br>OMZC2 1SCA101001R1001 99 OT200E04CLP 1SCA108530R1001 26<br>Dual power source ODPSE230C 1SCA116892R1001 74 OT200E04WCLP 1SCA108532R1001 26<br>ODPSE230C 1SCA116892R1001 100 OT250E03CLP 1SCA108593R1001 26<br>Dual power source ODPS230 1SCA122946R1001 74 OT250E03WCLP 1SCA107576R1001 26<br>including ATS functionality ODPS230 1SCA122946R1001 100 OT250E04CLP 1SCA108605R1001 26<br>Fourth poles OTPS40FPN1 1SCA105001R1001 42<br>OTPS40FPN2 1SCA105000R1001 42<br>Fourth poles OTPS80FP 1SCA105461R1001 42<br>OTPS125FP 1SCA105099R1001 42<br>**----- End of picture text -----**<br> Transfer, change-over and bypass switches | 1SCC303003C0201 | 123 ## Transfer, change-over and bypass switches Index **==> picture [528 x 634] intentionally omitted <==** **----- Start of picture text -----**<br> Description Type Order number Page Description Type Order number Page<br>Manual change-over switches, OT250E04WCLP 1SCA108607R1001 26 Manual change-over switches, OT200E04WCP 1SCA022775R0650 21<br>closed transition OT315E03CLP 1SCA108630R1001 26 open transition OT250E03CP 1SCA022771R3450 21<br>OT315E04CLP 1SCA106404R1001 26 OT250E03WCP 1SCA022772R8300 21<br>OT400E03CLP 1SCA108641R1001 26 OT250E04CP 1SCA022775R4640 21<br>OT400E04CLP 1SCA106405R1001 26 OT250E04WCP 1SCA022775R0810 21<br>OT630E03CLP 1SCA106917R1001 26 OT250E13CP 1SCA022777R0330 21<br>OT630E04CLP 1SCA106947R1001 26 OT250E33CP 1SCA118551R1001 21<br>OT800E03CLP 1SCA106928R1001 26 OT250E33WCP 1SCA118608R1001 21<br>OT800E04CLP 1SCA106952R1001 26 OT315E03CP 1SCA022772R6780 22<br>Manual change-over switches, OT160E03CFP 1SCA106086R1001 25 OT315E12CP 1SCA022776R9910 22<br>fast transition<br>OT160E03WCFP 1SCA108484R1001 25 OT315E04CP 1SCA022775R7150 22<br>OT160E04CFP 1SCA108489R1001 25 OT315E13CP 1SCA022777R0410 22<br>OT160E04WCFP 1SCA108492R1001 25 OT315E33CP 1SCA118635R1001 22<br>OT200E03CFP 1SCA108520R1001 25 OT400E03CP 1SCA022771R8500 22<br>OT200E03WCFP 1SCA107578R1001 25 Manual change-over switches, OT400E12CP 1SCA022776R9590 22<br>OT200E04CFP 1SCA108528R1001 25 open transition OT400E04CP 1SCA022771R8680 22<br>OT200E04WCFP 1SCA108531R1001 25 OT400E13CP 1SCA022777R0500 22<br>OT250E03CFP 1SCA108591R1001 25 OT400E33CP 1SCA118629R1001 22<br>OT250E03WCFP 1SCA107577R1001 25 OT630E03CP 1SCA022785R6050 22<br>OT250E04CFP 1SCA108600R1001 25 OT630E12CP 1SCA022785R8690 22<br>OT250E04WCFP 1SCA108606R1001 25 OT630E04CP 1SCA022785R6130 22<br>OT315E03CFP 1SCA108629R1001 25 OT630E13CP 1SCA022785R9070 22<br>OT315E04CFP 1SCA114535R1001 25 OT630E33CP 1SCA118652R1001 22<br>OT400E03CFP 1SCA106360R1001 25 OT800E03CP 1SCA022785R6300 22<br>OT400E04CFP 1SCA108650R1001 25 OT800E12CP 1SCA022785R8850 22<br>OT630E03CFP 1SCA106915R1001 25 OT800E04CP 1SCA022785R6210 22<br>OT630E04CFP 1SCA108753R1001 25 OT800E13CP 1SCA022785R9230 22<br>OT800E03CFP 1SCA106916R1001 25 OT800E33CP 1SCA118649R1001 22<br>OT800E04CFP 1SCA106945R1001 25 OT1000E03CP 1SCA022872R1680 24<br>Manual change-over switches, OT16F3C 1SCA104816R1001 19 OT1000E04CP 1SCA022872R1500 24<br>open transition OT16F4C 1SCA104831R1001 19 OT1000E22CP 1SCA103289R1001 24<br>OT25F3C 1SCA104863R1001 19 OT1250E03CP 1SCA022872R0790 24<br>OT25F4C 1SCA104877R1001 19 OT1250E04CP 1SCA022872R1250 24<br>OT40F3C 1SCA104913R1001 19 OT1250E22CP 1SCA103311R1001 24<br>OT40F4C 1SCA104934R1001 19 OT1600E03CP 1SCA022872R1840 24<br>OT63F3C 1SCA105338R1001 19 OT1600E04CP 1SCA022872R2310 24<br>OT63F4C 1SCA105369R1001 19 OT1600E22CP 1SCA103303R1001 24<br>OT80F3C 1SCA105402R1001 19 OT2000E03CP 1SCA103908R1001 24<br>OT80F4C 1SCA105418R1001 19 OT2000E04CP 1SCA103912R1001 24<br>OT100F3C 1SCA105008R1001 19 OT2000E22CP 1SCA103953R1001 24<br>OT100F4C 1SCA105019R1001 19 OT2500E03CP 1SCA105615R1001 24<br>OT125F3C 1SCA105037R1001 19 OT2500E04CP 1SCA103906R1001 24<br>OT125F4C 1SCA105054R1001 19 OT2500E22CP 1SCA103902R1001 24<br>OT160E03CP 1SCA022772R6510 21 OT3200E03CP 1SCA129156R1001 24<br>OT160E03WCP 1SCA022772R8210 21 OT3200E04CP 1SCA129158R1001 24<br>OT160E04CP 1SCA022775R9440 21 OT3200E22CP 1SCA131131R1001 24<br>OT160E04WCP 1SCA022775R0220 21 Motorized bypass switches, OTM160E3YM230C 1SCA141435R1001 113<br>OT200E03CP 1SCA022771R7520 21 open transition OTM160E4YM230C 1SCA141436R1001 113<br>OT200E03WCP 1SCA022772R8720 21 OTM200E3YM230C 1SCA141437R1001 113<br>OT200E04CP 1SCA022771R7280 21 OTM200E4YM230C 1SCA141438R1001 113<br>**----- End of picture text -----**<br> 124 | 1SCC303003C0201 | Transfer, change-over and bypass switches ## Transfer, change-over and bypass switches Index **==> picture [527 x 634] intentionally omitted <==** **----- Start of picture text -----**<br> Description Type Order number Page Description Type Order number Page<br>Motorized bypass switches, OTM250E3YM230C 1SCA141439R1001 113 Motorized change-over switches, OTM315E4CM230C 1SCA022847R2870 57<br>open transition OTM250E4YM230C 1SCA140870R1001 113 open transition OTM400E2CM230V 1SCA121226R1001 57<br>OTM315E3YM230C 1SCA141440R1001 113 OTM400E3CM230C 1SCA022847R1630 57<br>OTM315E4YM230C 1SCA141441R1001 113 OTM400E4CM230C 1SCA022847R3250 57<br>OTM400E3YM230C 1SCA136735R1001 113 OTM630E2CM230V 1SCA121268R1001 58<br>OTM400E4YM230C 1SCA136677R1001 113 OTM630E3CM230C 1SCA103567R1001 58<br>OTM630E3YM230C 1SCA136615R1001 113 OTM630E4CM230C 1SCA022873R1990 58<br>OTM630E4YM230C 1SCA136613R1001 113 OTM800E2CM230V 1SCA121270R1001 58<br>OTM800E3YM230C 1SCA136616R1001 113 OTM800E3CM230C 1SCA103570R1001 58<br>OTM800E4YM230C 1SCA136614R1001 113 OTM800E4CM230C 1SCA022872R8340 58<br>OTM40F3CMA230V 1SCA120096R1001 55 OTM1000E2CM230V 1SCA121279R1001 58<br>OTM40F4CMA230V 1SCA120102R1001 55 OTM1000E3CM230C 1SCA112677R1001 58<br>OTM63F3CMA230V 1SCA120095R1001 55 OTM1000E4CM230C 1SCA112703R1001 58<br>OTM63F4CMA230V 1SCA120101R1001 55 OTM1250E2CM230V 1SCA121293R1001 58<br>OTM80F3CMA230V 1SCA120093R1001 55 OTM1250E3CM230C 1SCA112676R1001 58<br>OTM80F4CMA230V 1SCA120100R1001 55 OTM1250E4CM230C 1SCA112702R1001 58<br>OTM100F3CMA230V 1SCA120071R1001 55 OTM1600E2CM230V 1SCA121280R1001 58<br>OTM100F4CMA230V 1SCA120098R1001 55 OTM1600E3CM230C 1SCA112678R1001 58<br>OTM125F3CMA230V 1SCA120070R1001 55 OTM1600E4CM230C 1SCA112704R1001 58<br>Motorized change-over switches, OTM125F4CMA230V 1SCA120097R1001 55 OTM2000E2CM230V 1SCA121289R1001 58<br>open transition OTM40F3CMA24D 1SCA124061R1001 55 OTM2000E3CM230C 1SCA112709R1001 58<br>OTM40F4CMA24D 1SCA124063R1001 55 OTM2000E4CM230C 1SCA112712R1001 58<br>OTM63F3CMA24D 1SCA124060R1001 55 OTM2500E2CM230V 1SCA121291R1001 58<br>OTM63F4CMA24D 1SCA124064R1001 55 OTM2500E3CM230C 1SCA112710R1001 58<br>OTM80F3CMA24D 1SCA124059R1001 55 Motorized change-over switches, OTM2500E4CM230C 1SCA112713R1001 58<br>OTM80F4CMA24D 1SCA124062R1001 55 open transition OTM3200E3CM230C 1SCA129240R1001 58<br>OTM100F3CMA24D 1SCA124058R1001 55 OTM3200E4CM230C 1SCA129242R1001 58<br>OTM100F4CMA24D 1SCA124066R1001 55 OTM160E3CM110V 1SCA022845R8530 59<br>OTM125F3CMA24D 1SCA124057R1001 55 OTM160E3WCM110V 1SCA022846R3450 59<br>OTM125F4CMA24D 1SCA124065R1001 55 OTM160E4CM110V 1SCA022846R1080 59<br>OTM160E2CM230V 1SCA121216R1001 57 OTM160E4WCM110V 1SCA022846R7360 59<br>OTM160E2WCM230V 1SCA121218R1001 57 OTM200E3CM110V 1SCA022845R8880 59<br>OTM160E3CM230C 1SCA022845R8610 57 OTM200E3WCM110V 1SCA022846R3880 59<br>OTM160E3WCM230C 1SCA022846R4000 57 OTM200E4CM110V 1SCA022846R1410 59<br>OTM160E4CM230C 1SCA022848R1510 57 OTM200E4WCM110V 1SCA022846R7790 59<br>OTM160E4WCM230C 1SCA022846R7440 57 OTM250E3CM110V 1SCA022845R9180 59<br>OTM200E2CM230V 1SCA121209R1001 57 OTM250E3WCM110V 1SCA022846R4690 59<br>OTM200E2WCM230V 1SCA121294R1001 57 OTM250E4CM110V 1SCA022846R1830 59<br>OTM200E3CM230C 1SCA022845R8960 57 OTM250E4WCM110V 1SCA022846R8170 59<br>OTM200E3WCM230C 1SCA022846R3960 57 OTM315E3CM110V 1SCA022847R1120 59<br>OTM200E4CM230C 1SCA022846R1590 57 OTM315E4CM110V 1SCA022847R2790 59<br>OTM200E4WCM230C 1SCA022846R7870 57 OTM400E3CM110V 1SCA022847R1550 59<br>OTM250E2CM230V 1SCA121211R1001 57 OTM400E4CM110V 1SCA022847R3170 59<br>OTM250E2WCM230V 1SCA121220R1001 57 OTM630E3CM110V 1SCA022873R1050 59<br>OTM250E3CM230C 1SCA022845R9260 57 OTM630E4CM110V 1SCA022873R1810 59<br>OTM250E3WCM230C 1SCA022846R4770 57 OTM800E3CM110V 1SCA022872R5750 59<br>OTM250E4CM230C 1SCA022846R1910 57 OTM800E4CM110V 1SCA022872R8260 59<br>OTM250E4WCM230C 1SCA022846R8250 57 OTM1000E3CM110V 1SCA113653R1001 59<br>OTM315E2CM230V 1SCA121221R1001 57 OTM1000E4CM110V 1SCA113656R1001 59<br>OTM315E3CM230C 1SCA022847R1210 57 OTM1250E3CM110V 1SCA113652R1001 59<br>**----- End of picture text -----**<br> Transfer, change-over and bypass switches | 1SCC303003C0201 | 125 ## Transfer, change-over and bypass switches Index **==> picture [528 x 634] intentionally omitted <==** **----- Start of picture text -----**<br> Description Type Order number Page Description Type Order number Page<br>Motorized change-over switches, OTM1250E4CM110V 1SCA113655R1001 59 Motorized change-over switches, OTM315E4CM24D 1SCA022847R2520 61<br>open transition OTM1600E3CM110V 1SCA113654R1001 59 open transition OTM400E3CM24D 1SCA022847R1390 61<br>OTM1600E4CM110V 1SCA113657R1001 59 OTM400E4CM24D 1SCA022847R2950 61<br>OTM2000E3CM110V 1SCA113683R1001 59 OTM630E3CM24D 1SCA022873R1210 61<br>OTM2000E4CM110V 1SCA113685R1001 59 OTM630E4CM24D 1SCA022873R2020 61<br>OTM2500E3CM110V 1SCA113684R1001 59 OTM800E3CM24D 1SCA022872R5910 61<br>OTM2500E4CM110V 1SCA113686R1001 59 OTM800E4CM24D 1SCA022872R8420 61<br>OTM160E3CM48D 1SCA022845R8450 60 OTM1000E3CM24D 1SCA113672R1001 61<br>OTM160E3WCM48D 1SCA022846R3370 60 OTM1000E4CM24D 1SCA113675R1001 61<br>OTM160E4CM48D 1SCA022846R0940 60 OTM1250E3CM24D 1SCA113671R1001 61<br>OTM160E4WCM48D 1SCA022846R7280 60 OTM1250E4CM24D 1SCA113674R1001 61<br>OTM200E3CM48D 1SCA022845R8700 60 OTM1600E3CM24D 1SCA113673R1001 61<br>OTM200E3WCM48D 1SCA022846R3700 60 OTM1600E4CM24D 1SCA113676R1001 61<br>OTM200E4CM48D 1SCA022846R1320 60 OTM2000E3CM24D 1SCA113695R1001 61<br>OTM200E4WCM48D 1SCA022846R7610 60 OTM2000E4CM24D 1SCA113697R1001 61<br>OTM250E3CM48D 1SCA022845R9000 60 OTM2500E3CM24D 1SCA113696R1001 61<br>OTM250E3WCM48D 1SCA022846R4510 60 OTM2500E4CM24D 1SCA113698R1001 61<br>OTM250E4CM48D 1SCA022846R1750 60 Panel fasteners OMZD1 1SCA022787R5190 72<br>OTM250E4WCM48D 1SCA022846R8090 60 OMZD1 1SCA022787R5190 99<br>OTM315E4CM48D 1SCA022847R2610 60 Parallel connection kits OMZC003 1SCA121324R1001 70<br>OTM400E3CM48D 1SCA022847R1470 60 OMZC004 1SCA121325R1001 70<br>OTM400E4CM48D 1SCA022847R3090 60 OMZC03 1SCA117037R1001 70<br>OTM315E3CM48D 1SCA022847R1040 60 OMZC04 1SCA117038R1001 70<br>OTM630E3CM48D 1SCA022873R1300 60 Phase barriers PB100 low 1SDA054970R1 40<br>OTM630E4CM48D 1SCA022873R2110 60 PB200 high 1SDA054972R1 40<br>OTM800E3CM48D 1SCA022872R6050 60 PB100 low 1SDA054971R1 40<br>OTM800E4CM48D 1SCA022872R8510 60 PB200 high 1SDA054973R1 40<br>OTM1000E3CM48D 1SCA113663R1001 60 PB100 low 1SDA054970R1 40<br>OTM1000E4CM48D 1SCA113666R1001 60 PB200 high 1SDA054972R1 40<br>OTM1250E3CM48D 1SCA113662R1001 60 PB100 low 1SDA054971R1 40<br>OTM1250E4CM48D 1SCA113665R1001 60 PB200 high 1SDA054973R1 40<br>OTM1600E3CM48D 1SCA113664R1001 60 PB100 low 1SDA054970R1 40<br>OTM1600E4CM48D 1SCA113667R1001 60 PB200 high 1SDA054972R1 40<br>OTM2000E3CM48D 1SCA113689R1001 60 PB100 low 1SDA054971R1 40<br>OTM2000E4CM48D 1SCA113691R1001 60 PB200 high 1SDA054973R1 40<br>OTM2500E3CM48D 1SCA113690R1001 60 PB100 low 1SDA054970R1 68<br>OTM2500E4CM48D 1SCA113692R1001 60 PB200 high 1SDA054972R1 68<br>OTM160E3CM24D 1SCA022845R8110 61 PB100 low 1SDA054971R1 68<br>OTM160E3WCM24D 1SCA022846R3290 61 PB200 high 1SDA054973R1 68<br>OTM160E4CM24D 1SCA022846R0860 61 PB100 low 1SDA054970R1 68<br>OTM160E4WCM24D 1SCA022846R7100 61 PB200 high 1SDA054972R1 68<br>OTM200E3CM24D 1SCA022845R8290 61 PB100 low 1SDA054971R1 68<br>OTM200E3WCM24D 1SCA022846R3610 61 PB200 high 1SDA054973R1 68<br>OTM200E4CM24D 1SCA022846R1240 61 PB100 low 1SDA054970R1 68<br>OTM200E4WCM24D 1SCA022846R7520 61 PB200 high 1SDA054972R1 68<br>OTM250E3CM24D 1SCA022845R8370 61 PB100 low 1SDA054971R1 68<br>OTM250E3WCM24D 1SCA022846R4420 61 PB200 high 1SDA054973R1 68<br>OTM250E4CM24D 1SCA022846R1670 61 PB100 low 1SDA054970R1 95<br>OTM250E4WCM24D 1SCA022846R7950 61 PB200 high 1SDA054972R1 95<br>OTM315E3CM24D 1SCA022847R0910 61 PB100 low 1SDA054971R1 95<br>**----- End of picture text -----**<br> 126 | 1SCC303003C0201 | Transfer, change-over and bypass switches ## Transfer, change-over and bypass switches Index **==> picture [527 x 660] intentionally omitted <==** **----- Start of picture text -----**<br> Description Type Order number Page Description Type Order number Page<br>Phase barriers PB200 high 1SDA054973R1 95 Plastic handle OTV250ECLK 1SCA113137R1001 36<br>PB100 low 1SDA054970R1 95 for closed transition types OTV400ECLK 1SCA113143R1001 36<br>PB200 high 1SDA054972R1 95 OTV800ECLK 1SCA113148R1001 36<br>PB100 low 1SDA054971R1 95 OTV1000ECLK 1SCA113152R1001 36<br>PB200 high 1SDA054973R1 95 Plastic handle, OTV250ECK 1SCA022783R0090 36<br>PB100 low 1SDA054970R1 95 direct mounting OTV400ECK 1SCA022783R0170 36<br>PB200 high 1SDA054972R1 95 OTV800ECK 1SCA022797R2470 36<br>PB100 low 1SDA054971R1 95 OTV1000ECK 1SCA107481R1001 36<br>PB200 high 1SDA054973R1 95 OHB65D6CM 1SCA022807R9430 36<br>PB100 low 1SDA054970R1 113 OTV250ECMK 1SCA022804R0570 66<br>PB200 high 1SDA054972R1 113 OTV400ECMK 1SCA022843R2900 66<br>PB100 low 1SDA054971R1 113 OTV800ECMK 1SCA022804R3410 66<br>PB200 high 1SDA054973R1 113 OTV1000ECMK 1SCA111301R1001 66<br>PB100 low 1SDA054970R1 113 Plastic handle, OTV250ECFK 1SCA113141R1001 36<br>PB200 high 1SDA054972R1 113 handle not padlockable OTV400ECFK 1SCA113147R1001 36<br>PB100 low 1SDA054970R1 117 OTV800ECFK 1SCA113151R1001 36<br>PB200 high 1SDA054972R1 117 Reversing bars OTZR1 1SCA100352R1001 42<br>PB100 low 1SDA054971R1 117 OTZR2 1SCA104647R1001 42<br>PB200 high 1SDA054973R1 117 OTZR3 1SCA100355R1001 42<br>PB100 low 1SDA054970R1 117 OTZR1 1SCA100352R1001 69<br>PB200 high 1SDA054972R1 117 OTZR2 1SCA104647R1001 69<br>PB100 low 1SDA054971R1 117 OTZR3 1SCA100355R1001 69<br>PB200 high 1SDA054973R1 117 OTZR1 1SCA100352R1001 97<br>PB100 low 1SDA054970R1 117 OTZR2 1SCA104647R1001 97<br>PB200 high 1SDA054972R1 117 OTZR3 1SCA100355R1001 97<br>PB100 low 1SDA054971R1 117 OTZR1 1SCA100352R1001 119<br>PB200 high 1SDA054973R1 117 OTZR2 1SCA104647R1001 119<br>Pistol handle for OHB65J6E65 1SCA112050R1001 36 OTZR3 1SCA100355R1001 119<br>closed transition types OHB95J12E65 1SCA112056R1001 36 Selector handle OHBS2AJE011 1SCA105220R1001 35<br>OHB145J12E65 1SCA112063R1001 36 OHYS2AJE011 1SCA105301R1001 35<br>OHB200J12PE65 1SCA112078R1001 36 Shafts for pistol handles OXP6X150 1SCA022295R5600 38<br>Pistol handle, OHB65J6E69 1SCA112052R1001 35 OXP6X170 1SCA108224R1001 38<br>handle not padlockable OHB95J12E69 1SCA112058R1001 35 OXP6X265 1SCA108225R1001 38<br>and no door interlocking<br>OHB145J12E69 1SCA112066R1001 35 OXP6X400 1SCA108226R1001 38<br>Pistol handle, OHB45J6E311 1SCA022817R2130 35 OXP6X90 1SCA022064R1180 38<br>padlockable in all positions OHY45J6E311 1SCA022817R2300 35 OXP6X130 1SCA022057R0570 38<br>OHB65J6E311 1SCA022662R4730 35 OXP6X161 1SCA022067R1760 38<br>OHB95J12E311 1SCA022779R2140 35 OXP6X210 1SCA022295R6080 38<br>OHB125J12E311 1SCA022615R1730 35 OXP6X290 1SCA022042R6370 38<br>OHB200J12PE311 1SCA104685R1001 35 OXP6X360 1SCA022042R6530 38<br>Pistol handle, OHB45J6E011 1SCA022594R7110 35 OXP6/12x161C 1SCA111724R1001 38<br>padlockable in the O-position OHY45J6E011 1SCA022817R2210 35 OXP12X107 1SCA022029R9750 38<br>OHB65J6E011 1SCA022383R2480 35 OXP12X148 1SCA022658R5570 38<br>OHY65J6E011 1SCA022779R1840 35 OXP12X166 1SCA022325R7100 38<br>OHB95J12E011 1SCA022621R0760 35 OXP12X185 1SCA022325R6710 38<br>OHY95J12E011 1SCA022621R0920 35 OXP12X250 1SCA022325R6980 38<br>OHB125J12E011 1SCA022589R3340 35 OXP12X280 1SCA022137R5140 38<br>OHY125J12E011 1SCA022615R1650 35 OXP12X325 1SCA022042R5810 38<br>OHB274J12E011 1SCA122306R1001 35<br>OHB200J12PE011 1SCA022873R4230 35<br>Pistol handle, OHY200J12PE011 1SCA104686R1001 35<br>padlockable in the O-position<br>**----- End of picture text -----**<br> Transfer, change-over and bypass switches | 1SCC303003C0201 | 127 ## Transfer, change-over and bypass switches Index **==> picture [528 x 660] intentionally omitted <==** **----- Start of picture text -----**<br> Description Type Order number Page Description Type Order number Page<br>Shafts for pistol handles OXP12X395 1SCA022042R5990 38 Terminal clamp sets OZXB2/1 1SCA022194R0200 41<br>for Al- and Cu-cables<br>OXP12X465 1SCA022042R6020 38 OZXB2L 1SCA022158R7750 41<br>OXP12X148 1SCA022658R5570 38 OZXB2L/1 1SCA022194R0460 41<br>OXP12X185 1SCA022325R6710 38 OZXB8 1SCA022744R1510 41<br>OXP12X250 1SCA022325R6980 38 OZXB8/1 1SCA022744R1600 41<br>OXP12X325 1SCA022042R5810 38 OZXB9 1SCA022750R3210 41<br>OXP12X395 1SCA022042R5990 38 OZXB9/1 1SCA022750R3300 41<br>OXP12X465 1SCA022042R6020 38 OZXB2L 1SCA022158R7750 41<br>OXP12X166 1SCA022325R7100 38 OZXB2L/1 1SCA022194R0460 41<br>OXP12X185 1SCA022325R6710 38 OZXB3 1SCA022136R8100 41<br>OXP12X250 1SCA022325R6980 38 OZXB3/1 1SCA022194R0620 41<br>OXP12X325 1SCA022042R5810 38 OZXB4 1SCA022137R4760 41<br>OXP12X395 1SCA022042R5990 38 OZXB4/1 1SCA022194R0890 41<br>OXP12X465 1SCA022042R6020 38 OZXB7 1SCA022185R0040 41<br>Shafts for OXS6X85 1SCA101647R1001 38 OZXB7/1 1SCA022194R1430 41<br>selector handle handles<br>OXS6X105 1SCA108043R1001 38 OZXB7L 1SCA022185R7130 41<br>OXS6X120 1SCA101654R1001 38 OZXB7L/1 1SCA022194R1600 41<br>OXS6X130 1SCA101655R1001 38 OZXB8 1SCA022744R1510 41<br>Terminal clamp sets OZXT1 1SCA022469R6310 68 OZXB8/1 1SCA022744R1600 41<br>OZXT2 1SCA022620R7200 68 OZXB9 1SCA022750R3210 41<br>OZXT3 1SCA022639R0720 68 OZXB9/1 1SCA022750R3300 41<br>OZXT6 1SCA122537R1001 68 OZXL1 1SCA022439R6770 118<br>OZXB1L 1SCA022169R2030 96 OZXL1 1SCA022439R6770 118<br>OZXB1L/1 1SCA022194R0030 96 OZXB1L 1SCA022169R2030 118<br>OZXB2 1SCA022119R7610 96 OZXB1L/1 1SCA022194R0030 118<br>OZXB2/1 1SCA022194R0200 96 OZXB2 1SCA022119R7610 118<br>OZXB2L 1SCA022158R7750 96 OZXB2/1 1SCA022194R0200 118<br>OZXB2L/1 1SCA022194R0460 96 OZXB2L 1SCA022158R7750 118<br>OZXB8 1SCA022744R1510 96 OZXB2L/1 1SCA022194R0460 118<br>OZXB8/1 1SCA022744R1600 96 OZXB8 1SCA022744R1510 118<br>OZXB9 1SCA022750R3210 96 OZXB8/1 1SCA022744R1600 118<br>OZXB9/1 1SCA022750R3300 96 OZXB9 1SCA022750R3210 118<br>OZXB2L 1SCA022158R7750 96 OZXB9/1 1SCA022750R3300 118<br>OZXB2L/1 1SCA022194R0460 96 OZXB2L 1SCA022158R7750 118<br>OZXB3 1SCA022136R8100 96 OZXB2L/1 1SCA022194R0460 118<br>OZXB3/1 1SCA022194R0620 96 OZXB3 1SCA022136R8100 118<br>OZXB4 1SCA022137R4760 96 OZXB3/1 1SCA022194R0620 118<br>OZXB4/1 1SCA022194R0890 96 OZXB4 1SCA022137R4760 118<br>OZXB7 1SCA022185R0040 96 OZXB4/1 1SCA022194R0890 118<br>OZXB7/1 1SCA022194R1430 96 OZXB7 1SCA022185R0040 118<br>OZXB7L 1SCA022185R7130 96 OZXB7/1 1SCA022194R1430 118<br>OZXB7L/1 1SCA022194R1600 96 OZXB7L 1SCA022185R7130 118<br>OZXB8 1SCA022744R1510 96 OZXB7L/1 1SCA022194R1600 118<br>OZXB8/1 1SCA022744R1600 96 OZXB8 1SCA022744R1510 118<br>OZXB9 1SCA022750R3210 96 OZXB8/1 1SCA022744R1600 118<br>OZXB9/1 1SCA022750R3300 96 OZXB9 1SCA022750R3210 118<br>Terminal clamp sets OZXL1 1SCA022439R6770 41 OZXB9/1 1SCA022750R3300 118<br>for Al- and Cu-cables<br>OZXB1L 1SCA022169R2030 41 Terminal clamp sets for Al- and OZXT1 1SCA022469R6310 41<br>Cu-cables insulated versions<br>OZXB1L/1 1SCA022194R0030 41 OZXT2 1SCA022620R7200 41<br>OZXB2 1SCA022119R7610 41 OZXT3 1SCA022639R0720 41<br>Terminal clamp sets for Al- and OZXT1 1SCA022469R6310 41<br>Cu-cables insulated versions<br>**----- End of picture text -----**<br> 128 | 1SCC303003C0201 | Transfer, change-over and bypass switches ## Transfer, change-over and bypass switches Index **==> picture [258 x 609] intentionally omitted <==** **----- Start of picture text -----**<br> Description Type Order number Page<br>Terminal shrouds, OTS40T1 1SCA105314R1001 39<br>for fourth pole switches OTS40T1 1SCA105314R1001 39<br>OTS63T1 1SCA022353R6910 39<br>OTS125T1 1SCA022379R9760 39<br>Terminal shrouds, OTS40T3 1SCA105317R1001 39<br>for three pole switches OTS63T3 1SCA022353R6750 39<br>OTS125T3 1SCA022379R9680 39<br>Terminal shrouds, OTS250G1L/3 1SCA022731R8150 39<br>grey plastic OTS250G1S/3 1SCA022731R8310 39<br>OTS250G1L/4 1SCA022731R8230 39<br>OTS250G1S/4 1SCA022731R8400 39<br>OTS400G1L/3 1SCA022736R8840 39<br>OTS400G1S/3 1SCA022736R9060 39<br>OTS400G1L/4 1SCA022736R9490 39<br>OTS400G1S/4 1SCA022736R9650 39<br>OTS800G1L/3 1SCA022776R7890 39<br>OTS800G1S/3 1SCA022776R8190 39<br>OTS800G1L/4 1SCA022776R7970 39<br>OTS800G1S/4 1SCA022776R8270 39<br>OTS1600G1L/3 1SCA022871R9510 39<br>OTS1600G1S/3 1SCA022871R9600 39<br>OTS1600G1L/4 1SCA022871R9780 39<br>OTS1600G1S/4 1SCA022871R9860 39<br>OTS2500G1L/3 1SCA107261R1001 39<br>OTS2500G1S/3 1SCA107260R1001 39<br>OTS2500G1L/4 1SCA107262R1001 39<br>OTS2500G1S/4 1SCA107271R1001 39<br>OTS4000G1L/3 1SCA129042R1001 39<br>OTS4000G1S/3 1SCA129044R1001 39<br>OTS4000G1L/4 1SCA129043R1001 39<br>OTS4000G1S/4 1SCA129045R1001 39<br>OTS125T3 1SCA022379R9680 67<br>OTS250G1L/3 1SCA022731R8150 67<br>OTS250G1S/3 1SCA022731R8310 67<br>OTS250G1L/4 1SCA022731R8230 67<br>OTS250G1S/4 1SCA022731R8400 67<br>OTS400G1L/3 1SCA022736R8840 67<br>OTS400G1S/3 1SCA022736R9060 67<br>OTS400G1L/4 1SCA022736R9490 67<br>OTS400G1S/4 1SCA022736R9650 67<br>OTS800G1L/3 1SCA022776R7890 67<br>OTS800G1S/3 1SCA022776R8190 67<br>OTS800G1L/4 1SCA022776R7970 67<br>OTS800G1S/4 1SCA022776R8270 67<br>OTS1600G1L/3 1SCA022871R9510 67<br>OTS1600G1S/3 1SCA022871R9600 67<br>OTS1600G1L/4 1SCA022871R9780 67<br>OTS1600G1S/4 1SCA022871R9860 67<br>**----- End of picture text -----**<br> **==> picture [258 x 636] intentionally omitted <==** **----- Start of picture text -----**<br> Description Type Order number Page<br>Terminal shrouds, OTS2500G1L/3 1SCA107261R1001 67<br>grey plastic OTS2500G1S/3 1SCA107260R1001 67<br>OTS2500G1L/4 1SCA107262R1001 67<br>OTS2500G1S/4 1SCA107271R1001 67<br>OTS4000G1L/3 1SCA129042R1001 67<br>OTS4000G1S/3 1SCA129044R1001 67<br>OTS4000G1L/4 1SCA129043R1001 67<br>OTS4000G1S/4 1SCA129045R1001 67<br>OTS250G1L/3 1SCA022731R8150 94<br>OTS250G1S/3 1SCA022731R8310 94<br>OTS250G1L/4 1SCA022731R8230 94<br>OTS250G1S/4 1SCA022731R8400 94<br>OTS400G1L/3 1SCA022736R8840 94<br>OTS400G1S/3 1SCA022736R9060 94<br>OTS400G1L/4 1SCA022736R9490 94<br>OTS400G1S/4 1SCA022736R9650 94<br>OTS800G1L/3 1SCA022776R7890 94<br>OTS800G1S/3 1SCA022776R8190 94<br>OTS800G1L/4 1SCA022776R7970 94<br>OTS800G1S/4 1SCA022776R8270 94<br>OTS1600G1L/3 1SCA022871R9510 94<br>OTS1600G1S/3 1SCA022871R9600 94<br>OTS1600G1L/4 1SCA022871R9780 94<br>OTS1600G1S/4 1SCA022871R9860 94<br>OTS250G1L/3 1SCA022731R8150 116<br>OTS250G1S/3 1SCA022731R8310 116<br>OTS250G1L/4 1SCA022731R8230 116<br>OTS250G1S/4 1SCA022731R8400 116<br>OTS400G1L/3 1SCA022736R8840 116<br>OTS400G1S/3 1SCA022736R9060 116<br>OTS400G1L/4 1SCA022736R9490 116<br>OTS400G1S/4 1SCA022736R9650 116<br>OTS800G1L/3 1SCA022776R7890 116<br>OTS800G1S/3 1SCA022776R8190 116<br>OTS800G1L/4 1SCA022776R7970 116<br>OTS800G1S/4 1SCA022776R8270 116<br>UL/CSA OT200U03CP 1SCA022771R5910 27<br>manual change-over switches OT200U04CP 1SCA022771R6210 27<br>OT400U03CP 1SCA022771R2810 27<br>OT400U04CP 1SCA022771R2300 27<br>OT600U03CP 1SCA022785R5320 27<br>OT600U04CP 1SCA022785R5410 27<br>OT800U03CP 1SCA104031R1001 27<br>OT800U04CP 1SCA104036R1001 27<br>Voltage sensing connectors OMZB18 1SCA120153R1001 70<br>OMZB28 1SCA120154R1001 70<br>OMZB38 1SCA120155R1001 70<br>OMZB48 1SCA120156R1001 70<br>**----- End of picture text -----**<br> Transfer, change-over and bypass switches | 1SCC303003C0201 | 129 ## Transfer, change-over and bypass switches Index **==> picture [258 x 474] intentionally omitted <==** **----- Start of picture text -----**<br> Description Type Order number Page<br>Manual bypass switches, OT160E03YLP 1SCA145895R1001 111<br>Closed transition<br>OT160E04YLP 1SCA145907R1001 111<br>OT200E03YLP 1SCA145896R1001 111<br>OT200E04YLP 1SCA145908R1001 111<br>OT250E03YLP 1SCA145897R1001 111<br>OT250E04YLP 1SCA145909R1001 111<br>OT400E03YLP 1SCA145932R1001 111<br>OT400E04YLP 1SCA145938R1001 111<br>OT630E03YLP 1SCA145954R1001 111<br>OT630E04YLP 1SCA145960R1001 111<br>OT800E03YLP 1SCA145955R1001 111<br>OT800E04YLP 1SCA145961R1001 111<br>UL/CSA OT30F3C 1SCA105071R1001 27<br>manual change-over switches OT30F4C 1SCA146051R1001 27<br>OT60F3C 1SCA105078R1001 27<br>OT60F4C 1SCA146053R1001 27<br>OT100F3C 1SCA105008R1001 27<br>OT100F4C 1SCA105019R1001 27<br>**----- End of picture text -----**<br> 130 | 1SCC303003C0201 | Transfer, change-over and bypass switches For your notes Transfer, change-over and bypass switches | 1SCC303003C0201 | 131 ## For your notes 132 | 1SCC303003C0201 | Transfer, change-over and bypass switches Contact us ## ABB Oy ## Protection and Connection P.O. Box 622 FI-65101 Vaasa, Finland Phone: +358 10 22 11 Fax: +358 10 22 45708 Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. www.abb.com Find the address of your local sales organization on the ABB homepage: ## www.abb.com/contacts We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents – in whole or in parts – is forbidden without prior written consent of ABB AG. > Low Voltage Products and Systems Copyright © 2016 ABB All rights reserved
Updated at April 23, 2026
ABB is a global leader in power and automation technologies, recognized for delivering innovative solutions that improve performance while minimizing environmental impact. Serving a diverse range of sectors including industrial processing, OEM, and building services, ABB provides highly reliable components designed to meet the rigorous demands of modern electrical systems. The company is particularly renowned for its advanced circuit protection solutions. This includes a comprehensive selection of thermal magnetic circuit breakers, alongside specialized RCBO, RCD, GFCI, and AFDD circuit breakers. These foundational safety components are supported by a wide array of high-quality fuse holders and circuit breaker accessories, ensuring complete protection for complex industrial and commercial installations. Beyond circuit protection, ABB excels in automation and process control. Their offering features sophisticated visual signal indicator units, industrial switch accessories, and panel instrumentation designed for intuitive system monitoring. Additionally, ABB manufactures a robust range of power relays, safety relays, and AC/DC converters, providing engineers with the critical building blocks needed for efficient, secure, and reliable control panels.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →