- Manufacturer: MEAN WELL
- Product type: AC / DC LED Power Supplies
- SVHC: No SVHC (12-Jan-2017)
- Product Range: ODLV-45
- Output Current: 750mA
- LED Driver Mode: Constant Voltage
- Output Power Max: 45W
- Input Voltage Max: 295V
- Input Voltage Min: 90V
- Output Voltage Max: 60VDC
- Power Supply Applications: LED Lighting
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 36.1 € |
| Current stock | 10+ |
| Lead time | 30 days |
**==> picture [520 x 745] intentionally omitted <==** 45W PWM Output LED Driver ## **ODLV- 45 series** ## **SPECIFICATION** |**SPECIFICATION**|**SPECIFICATION**|||||| |---|---|---|---|---|---|---| |**ODLV-45 -12**<br>**ODLV-45 -24**<br>**ODLV-45 -36**<br>**ODLV-45 -48**<br>**ODLV-45 -60**<br>**MODEL**<br>**OUTPUT**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT(Typ.)**<br>**LEAKAGE CURRENT**<br>**SAFETY STANDARDS**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVER CURRENT**<br>47 ~ 63Hz<br>105 ~ 115%<br>20 ~ 90% RH non-condensing<br>-40 ~ +80<br>, 10 ~ 95% RH<br>℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)<br>10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**PROTECTION**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**TOTAL HARMONIC DISTORTION**<br>I/P-O/P:3.75KVAC<br>I/P-O/P:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>±10%<br>0~100%<br>84%<br>86%<br>88%<br>88%<br>90%<br>0.6A / 115VAC 0.4A / 230VAC 0.3A / 277VAC<br><0.75mA / 277VAC<br>111*77*28.5mm (L*W*H)<br>0.42Kg;24pcs/11Kg/ 0.72CUFT<br>**SHORT CIRCUIT**<br>**DIMMING RANGE**<br>**DC VOLTAGE**<br>**RATED POWER**<br>**SETUP TIME Note.3**<br>**VOLTAGE TOLERANCE**<br>**VOLTAGE RANGE Note.2**<br>1KHz( 20%)<br>±<br>500ms / 230VAC 1200ms/115VAC<br>12V<br>24V<br>36V<br>48V<br>60V<br>3.0A<br>1.88A<br>1.25A<br>0.94A<br>36W<br>45.12W<br>45W<br>45.12W<br>0.75A<br>45W<br>**PWM FREQUENCY (Typ.)**<br>**AUXILIARY DC OUTPUT Note.4**<br>Nominal 12V(deviation 11.4~12.6)@50mA for A-Type only<br>(Please refer to "STATIC CHARACTERISTIC" section)<br>90 ~ 295VAC 127 ~ 417VDC<br>PF>0.95/115VAC, PF>0.92/230VAC, PF>0.9/277VAC@full load<br>(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)<br>THD< 20%(@load 60%/115VAC,230VAC; @load 75%/277VAC)<br>≧<br>≧<br>(Please refer to “TOTAL HARMONIC DISTORTION” section)<br>COLD START 30A(twidth=<br>s measured at 50% Ipeak) at 230VAC<br>150μ<br>;Per NEMA 410<br><0.5W for Blank-Type, <1.2W for A-Type<br>**NO LOAD POWER CONSUMPTION**<br>**WORKING TEMP.**<br>**MAX. CASE TEMP.**<br>Tcase=-20 ~ +85<br>(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)<br>℃<br>Tcase=+85℃<br>Compliance to EN55015, EN61000-3-2 Class C (<br>) ; EN61000-3-3,GB17743,GB17625.1,EAC TP TC 020<br>@load<br>60%<br>≧<br>Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level(<br>),EAC TP TC 020<br>surge immunity:Line-Line:1KV<br>℃<br>℃<br>℃<br>**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**<br>32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>**RATED CURRENT**<br>388.02K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>Shut down O/P voltage, re-power on to recovery<br>UL8750<br>,CSA C22.2 NO.250.13-12;<br>(type”HL”)<br>ENEC EN61347-1 & EN61347-2-13 independent, EN62384,GB19510.1,GB19510.14;<br>BIS IS15885( for ODLV-45-12,24,48 only), EAC TP TC 004,IP67 approved<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated current and 25 _ ofambienttemperature.<br>2. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.<br>3. Length of set up time is measured at cold first start. Turning ON/OFF the driver may lead to increase of the set up time.<br>4. Aux. 12V will bedamaged with short circuit; It will not be available with dimming off or output no load condition.<br>5. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be<br>affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.<br>6. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>7. For any application note and IP water proof function installation caution, please refer our user manual before using.<br>https:/www.meanwell.com/Upload/PDF/LED_EN.pdf||**ODLV-45 -12**|**ODLV-45 -24**|**ODLV-45 -36**|**ODLV-45 -48**|**ODLV-45 -60**| ||**DC VOLTAGE**|12V|24V|36V|48V|60V| ||**RATED CURRENT**|3.0A|1.88A|1.25A|0.94A|0.75A| ||**RATED POWER**|36W|45.12W|45W|45.12W|45W| ||**DIMMING RANGE**|0~100%||||| ||**VOLTAGE TOLERANCE**|±10%||||| ||**PWM FREQUENCY (Typ.)**|1KHz( 20%)<br>±||||| ||**SETUP TIME Note.3**|500ms / 230VAC 1200ms/115VAC||||| ||**AUXILIARY DC OUTPUT Note.4**|Nominal 12V(deviation 11.4~12.6)@50mA for A-Type only||||| ||**VOLTAGE RANGE Note.2**|(Please refer to "STATIC CHARACTERISTIC" section)<br>90 ~ 295VAC 127 ~ 417VDC||||| ||**FREQUENCY RANGE**|47 ~ 63Hz||||| ||**POWER FACTOR (Typ.)**|PF>0.95/115VAC, PF>0.92/230VAC, PF>0.9/277VAC@full load<br>(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)||||| ||**TOTAL HARMONIC DISTORTION**|THD< 20%(@load 60%/115VAC,230VAC; @load 75%/277VAC)<br>≧<br>≧<br>(Please refer to “TOTAL HARMONIC DISTORTION” section)||||| ||**EFFICIENCY (Typ.)**|84%|86%|88%|88%|90%| ||**AC CURRENT (Typ.)**|0.6A / 115VAC 0.4A / 230VAC 0.3A / 277VAC||||| ||**INRUSH CURRENT(Typ.)**|COLD START 30A(twidth=<br>s measured at 50% Ipeak) at 230VAC<br>150μ<br>;Per NEMA 410||||| ||**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**|32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC||||| ||**LEAKAGE CURRENT**|<0.75mA / 277VAC||||| ||**NO LOAD POWER CONSUMPTION**|<0.5W for Blank-Type, <1.2W for A-Type||||| ||**SHORT CIRCUIT**|Shut down O/P voltage, re-power on to recovery||||| ||**OVER CURRENT**|105 ~ 115%<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed||||| ||**WORKING TEMP.**|Tcase=-20 ~ +85<br>(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)<br>℃||||| ||**MAX. CASE TEMP.**|Tcase=+85℃||||| ||**WORKING HUMIDITY**|20 ~ 90% RH non-condensing||||| ||**STORAGE TEMP., HUMIDITY**|-40 ~ +80<br>, 10 ~ 95% RH<br>℃||||| ||**TEMP. COEFFICIENT**|±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)||||| ||**VIBRATION**|10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes||||| ||**SAFETY STANDARDS**|UL8750<br>,CSA C22.2 NO.250.13-12;<br>(type”HL”)<br>ENEC EN61347-1 & EN61347-2-13 independent, EN62384,GB19510.1,GB19510.14;<br>BIS IS15885( for ODLV-45-12,24,48 only), EAC TP TC 004,IP67 approved||||| ||**WITHSTAND VOLTAGE**|I/P-O/P:3.75KVAC||||| ||**ISOLATION RESISTANCE**|I/P-O/P:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃||||| ||**EMC EMISSION**|Compliance to EN55015, EN61000-3-2 Class C (<br>) ; EN61000-3-3,GB17743,GB17625.1,EAC TP TC 020<br>@load<br>60%<br>≧||||| ||**EMC IMMUNITY**|Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level(<br>),EAC TP TC 020<br>surge immunity:Line-Line:1KV||||| ||**MTBF**|388.02K hrs min. MIL-HDBK-217F (25<br>)<br>℃||||| ||**DIMENSION**|111*77*28.5mm (L*W*H)||||| ||**PACKING**<br>0.42Kg;24pcs/11Kg/ 0.72CUFT<br>℃<br>℃<br>℃<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated current and 25 _ ofambienttemperature.<br>2. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.<br>3. Length of set up time is measured at cold first start. Turning ON/OFF the driver may lead to increase of the set up time.<br>4. Aux. 12V will bedamaged with short circuit; It will not be available with dimming off or output no load condition.<br>5. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be<br>affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.<br>6. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>7. For any application note and IP water proof function installation caution, please refer our user manual before using.<br>https:/www.meanwell.com/Upload/PDF/LED_EN.pdf|||||| _File Name:ODLV-45-SPEC 2018-09-29_ **ODLV- 45 series** 45W PWM Output LED Driver ## **DIMMING OPERATION** **==> picture [47 x 67] intentionally omitted <==** **----- Start of picture text -----**<br> AUX-(Green)<br>AUX+(Yellow)<br>V0-(Black)<br>V0+(Red)<br>DIM-(Gray)<br>DIM+(Purple)<br>ACN(Blue)<br>ACL(Brown)<br>**----- End of picture text -----**<br> ※ **Dimming principle for PWM style output** - �Dimming is achieved by varying the duty cycle of the output current. **==> picture [436 x 435] intentionally omitted <==** **----- Start of picture text -----**<br> ON<br>Output DC current<br>TON<br>Duty cycle(%) = ×100%<br>T<br>OFF Output PWM frequency : 1KHz(±20%)<br>Io=0A<br>TON<br>T<br> 2 in 1 dimming function<br>Applying additive 0 ~ 10VDC 100%<br>90%<br>80%<br>+<br>Vo+ + 70%<br>60%<br>-<br>Vo- - 50%<br>DIM+ 40%<br>+<br>Additive Voltage 30%<br>- 20%<br>DIM-<br>10%<br>“DO NOT connect "DIM- to Vo-” 0%<br>0V 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V<br>Dimming input: Additive voltage<br>Applying additive 10V PWM signal (frequency range 300~3000Hz): 100%<br>90%<br>80%<br>+<br>Vo+ + 70%<br>60%<br>-<br>Vo- - 50%<br>DIM+ 40%<br>Additive PWM signal 30%<br>20%<br>DIM-<br>10%<br>“DO NOT connect "DIM- to Vo-” 0%<br>0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>Duty cycle of additive 10V PWM signal dimming input<br>Duty cycle of output current (%)<br>Duty cycle of output current (%)<br>**----- End of picture text -----**<br> ※ **2 in 1 dimming function** **==> picture [97 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> ◎ Applying additive 0 ~ 10VDC<br>**----- End of picture text -----**<br> **==> picture [219 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> ◎ Applying additive 10V PWM signal (frequency range 300~3000Hz):<br>**----- End of picture text -----**<br> Note : 1. Min. duty cycle of output current is about 8% and the output current is not defined when 0%< Iout<8%. 2. The duty cycle of output current could drop down to 0% when dimming input is about 0Vdc or 10V PWM signal with 0% duty cycle. _File Name:ODLV-45-SPEC 2018-09-29_ **ODLV- 45 series** 45W PWM Output LED Driver ## **OUTPUT LOAD vs TEMPERATURE** **==> picture [505 x 601] intentionally omitted <==** **----- Start of picture text -----**<br> 100 100<br>80 80<br>70 70<br>60 60<br>40 40<br>20 20<br>-20 -10 0 10 20 30 40 50 (HORIZONTAL) -20 -10 0 15 30 45 60 85 (HORIZONTAL)<br>AMBIENT TEMPERATURE,Ta ( ℃ ) Tcase ( ℃ )<br>STATIC CHARACTERISTIC POWER FACTOR (PF) CHARACTERISTIC<br>※ Tcase at 75℃<br>100<br>90 for 12V model 1.00<br>80<br>0.95<br>70 for others<br>0.90 277(45W)<br>60 230(45W)<br>0.85 115(36W)<br>50<br>40 0.80<br>0.75<br>90 100 135 180 200 230 295 50% 60% 70% 80% 90% 100%<br>INPUT VOLTAGE (V) LOAD<br>※De-rating is needed under low input voltage.<br>TOTAL HARMONIC DISTORTION (THD) EFFICIENCY vs LOAD<br>ODLV-45 series possess superior working efficiency that up to 90% can<br>be reached in field applications.<br>※ 60V Model,Tcase at 75℃ 60V Model,Tcase at 75<br>91%<br>19.00%<br>90%<br>17.00%<br>15.00% 89% 277(45W)<br>13.00% 277(45W)230(45W) 88% 230(45W)115(36W)<br>11.00% 115(36W)<br>87%<br>9.00%<br>7.00% 86%<br>5.00%<br>50% 60% 70% 80% 90% 100% 85%<br>50% 60% 70% 80% 90% 100%<br>LOAD<br>LOAD<br>LOAD (%) LOAD (%)<br>PF<br>LOAD (%)<br>THD(%)<br>EFFICIENCY(%)<br>**----- End of picture text -----**<br> _File Name:ODLV-45-SPEC 2018-09-29_ ## 45W PWM Output LED Driver ## **ODLV- 45 series** ## **BLOCK DIAGRAM** **==> picture [460 x 145] intentionally omitted <==** **----- Start of picture text -----**<br> fosc : 70~150KHz<br>RECTIFIERS AUX+(for A-Type)<br>AUX-(for A-Type)<br>EMI FILTER POWER RECTIFIERS Vo+<br>I/P & SWITCHING &<br>RECTIFIERS FILTER Vo-<br>CURRENT DIM+<br>LIMIT DIM-<br>O.L.P. DETECTION<br>PWM&PFC CIRCUIT<br>CONTROL<br>**----- End of picture text -----**<br> ## **DRIVING METHODS OF LED MODULE** ※ This series work in Constant Voltage mode to drive the LEDs. **==> picture [460 x 150] intentionally omitted <==** **----- Start of picture text -----**<br> In the constant current region, the highest voltage at the output of the driver<br>100<br>depends on the configuration of the end systems.<br>Should there be any compatibility issues, please contact MEAN WELL.<br>(B)<br>(A) Constant<br>Constant<br>Current area<br>Voltage area<br>50<br>(min.)<br>(C)<br>Hiccup<br>Protection<br>50 100 Io(%)<br>Typical output current normalized by rated current (%)<br>Vo(%)<br>**----- End of picture text -----**<br> _File Name:ODLV-45-SPEC 2018-09-29_ **ODLV- 45 series** ## 45W PWM Output LED Driver **==> picture [478 x 626] intentionally omitted <==** **----- Start of picture text -----**<br> MECHANICAL SPECIFICATION Case No.ODL-45A Unit:mm<br>111<br>※ Blank-Type:<br>3.5<br>200±10<br>Vo-(Black)<br>Vo+(Red) 30<br>DIM-(Gray)<br>DIM+(Purple)<br>150±10 tc<br>ACN(Blue)<br>ACL(Brown)<br>200±10<br>2*ψ4.5<br>�tc : Max. Case Temperature 3.5<br>AC wire No. Assignment(AC IN) DC wire No. Assignment(DC OUT)<br>ACN(Blue) SVT 18AWG Vo-(Black) UL1007 18AWG<br>ACL(Brown) SVT 18AWG Vo+(Red) UL1007 18AWG<br>DIM-(Gray) UL1007 22AWG<br>DIM+(Purple) UL1007 22AWG<br>※ A-Type:<br>111<br>3.5<br>200±10<br>150±10<br>AUX-(Green)<br>AUX+(Yellow)<br>Vo-(Black)<br>Vo+(Red) 30<br>DIM-(Gray)<br>DIM+(Purple)<br>150±10 tc<br>ACN(Blue)<br>ACL(Brown)<br>200±10<br>�tc : Max. Case Temperature 2*ψ4.5 3.5<br>AC wire No. Assignment(AC IN) DC wire No. Assignment(DC OUT)<br>ACN(Blue) SVT 18AWG AUX-(Green) UL1007 22AWG<br>ACL(Brown) SVT 18AWG AUX+(Yellow) UL1007 22AWG<br>Vo-(Black) UL1007 18AWG<br>Vo+(Red) UL1007 18AWG<br>DIM-(Gray) UL1007 22AWG<br>DIM+(Purple) UL1007 22AWG<br>INSTALLATION MANUAL<br>3.5<br>77<br>30 3.5<br>28.5<br>2.5<br>3.5<br>77<br>30 3.5<br>28.5<br>2.5<br>**----- End of picture text -----**<br> Please refer to : http://www.meanwell.com/manual.html _File Name:ODLV-45-SPEC 2018-09-29_
Updated at April 17, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →