Image not available
Illustrative purposes only
NPF-60D-24
LED Driver, Household & LED Lighting, 60 W, 24 V, 2.5 A, Constant Current, 90 VAC
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC LED Power Supplies
- SVHC: No SVHC (25-Jun-2025)
- Product Range: NPF-60D Series
- Output Current: 2.5A
- LED Driver Mode: Constant Current
- Output Power Max: 60W
- Input Voltage Max: 305VAC
- Input Voltage Min: 90VAC
- Output Voltage Max: 24V
- Power Supply Applications: Household & LED Lighting
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 24.65 € |
| Current stock | 10+ |
| Lead time | 30 days |
60W Single Output LED Driver ## **- NPF 60D series** **==> picture [42 x 5] intentionally omitted <==** **----- Start of picture text -----**<br> User’s Manual<br>**----- End of picture text -----**<br> ## ** IP67** VVY CH} cWhis **** ALis **** Ks Fl ## ■ **** - ‧ - ‧ - ‧ - ‧ - ‧ - ‧ - ‧ - ‧ ## ■ **** - ‧ - ‧ - ‧ - ‧ - ‧ - ‧ - ## ■ **** ## ■ **** ℃℃ ■ ** ** ~~=~~ **** _File Name:NPF-60D-SPEC 2022-02-18_ **- NPF 60D series** 60W Single Output LED Driver ## **SPECIFICATION** ||**MODEL**<br>**CONSTANT CURRENT REGION**<br>**RATED CURRENT**<br>**RATED POWER**<br>**OUTPUT**<br>**VOLTAGE RANGENote.2**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY(Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT(Typ.)**<br>**LEAKAGE CURRENT**<br>**SAFETY STANDARDS**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVER CURRENT**<br>**OVER VOLTAGE**<br>**OVER TEMPERATURE**<br>47 ~ 63Hz<br><0.25mA / 277VAC<br>95 ~ 108%<br>Constant current limiting, recovers automatically after fault condition is removed<br>Compliance to<br>@ load≧60%<br>BS EN/EN55015, BS EN/EN61000-3-2 Class C (<br>) ; BS EN/EN61000-3-3;<br>GB17743 and GB17625.1,EAC TP TC 020<br>Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN61547, light industry level(surge immunity Line-Line 2KV);<br>EAC TP TC 020<br>20 ~ 95% RH non-condensing<br>-40 ~ +80℃, 10 ~ 95% RH<br>±0.03%/℃(0 ~ 50℃)<br>10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes<br>3082.1K hrs min. Telcordia SR-332 (Bellcore) ; 287.9K hrs min. MIL-HDBK-217F (25℃)<br>℃<br><br><br><br><br><br>℃<br><br>℃℃<br><br>https://www.meanwell.com/Upload/PDF/LED_EN.pdf<br>※ : , https://www.meanwell.com/serviceDisclaimer.aspx<br>Shut down o/p voltage, re-power on to recover<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**PROTECTION**<br>Shut down o/p voltage, re-power on to recover<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>COLD START 50A(twidth=270 s measured at 50% Ipeak) at 230VAC<br>;Per NEMA 410<br>μ<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>17.5 ~ 21V<br>15 ~ 17V<br>23 ~ 27V<br>28 ~ 34V<br>34 ~ 40V<br>41 ~ 46V<br>54 ~ 60V<br>46 ~ 54V<br>59 ~ 66V<br>**NPF-60D-15**<br>**NPF-60D-12**<br>**NPF-60D-20**<br>**NPF-60D-24**<br>**NPF-60D-30**<br>**NPF-60D-36**<br>**NPF-60D-42**<br>**NPF-60D-48**<br>**NPF-60D-54**<br>**TOTAL HARMONIC DISTORTION**<br>I/P-O/P:3.75KVAC<br>I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH<br>**MAX. NO. of PSUs on 16A**<br>**CIRCUIT BREAKER**<br>9 units (circuit breaker of type B) / 16 units (circuit breaker of type C) at 230VAC<br>**SHORT CIRCUIT**<br>Hiccup mode, recovers automatically after fault condition is removed<br>**CURRENT TOLERANCE**<br>±5.0%<br>**CURRENT RIPPLE**<br>5.0% max. @rated current<br>**SET UP TIMENote.3**<br>500ms/115VAC, 230VAC<br>90 ~ 305VAC 127 ~ 431VDC<br>(Please refer to "STATIC CHARACTERISTIC" section)<br> PF≧0.97/115VAC, PF≧0.95/230VAC, PF≧0.92/277VAC@full load<br>(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)<br>THD< 20%(@load≧60%/115VC, 230VAC; @load≧75%/277VAC)<br>(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)<br><0.5W<br>**STANDBY POWER CONSUMPTION**<br>**WORKING TEMP.**<br>Tcase=-40 ~ +85℃(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)<br>**MAX. CASE TEMP.**Tcase=+85℃<br>UL8750(type”HL”), UL879(for 12V,24V only), CSA C22.2 No. 250.13-12, ENEC BS EN/EN61347-1,<br>BS EN/EN61347-2-13, BS EN/EN62384 independent, EAC TP TC 004,GB19510.1,GB19510.14,<br>IP67 approved ; Design refer to BS EN/EN60335-1<br>150*53*35mm (L*W*H)<br>0.49Kg;30pcs/15.7Kg/1.0CUFT<br>60W<br>60W<br>60W<br>60W<br>60W<br>60.12W<br>60W<br>60.48W<br>60.06W<br>9 ~ 15V<br>7.2 ~ 12V<br>12 ~ 20V<br>14.4 ~ 24V<br>18 ~ 30V<br>21.6 ~ 36V<br>28.8 ~ 48V<br>32.4 ~ 54V<br>25.2 ~ 42V<br>4A<br>5A<br>3A<br>2.5A<br>1.67A<br>1.25A<br>1.12A<br>1.43A<br>2A<br>87%<br>86%<br>88%<br>89%<br>90%<br>90%<br>90%<br>90%<br>90%<br>0.8A / 115VAC 0.4A / 230VAC 0.32A / 277VAC|**MODEL**<br>**CONSTANT CURRENT REGION**<br>**RATED CURRENT**<br>**RATED POWER**<br>**OUTPUT**<br>**VOLTAGE RANGENote.2**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY(Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT(Typ.)**<br>**LEAKAGE CURRENT**<br>**SAFETY STANDARDS**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVER CURRENT**<br>**OVER VOLTAGE**<br>**OVER TEMPERATURE**<br>47 ~ 63Hz<br><0.25mA / 277VAC<br>95 ~ 108%<br>Constant current limiting, recovers automatically after fault condition is removed<br>Compliance to<br>@ load≧60%<br>BS EN/EN55015, BS EN/EN61000-3-2 Class C (<br>) ; BS EN/EN61000-3-3;<br>GB17743 and GB17625.1,EAC TP TC 020<br>Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN61547, light industry level(surge immunity Line-Line 2KV);<br>EAC TP TC 020<br>20 ~ 95% RH non-condensing<br>-40 ~ +80℃, 10 ~ 95% RH<br>±0.03%/℃(0 ~ 50℃)<br>10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes<br>3082.1K hrs min. Telcordia SR-332 (Bellcore) ; 287.9K hrs min. MIL-HDBK-217F (25℃)<br>℃<br><br><br><br><br><br>℃<br><br>℃℃<br><br>https://www.meanwell.com/Upload/PDF/LED_EN.pdf<br>※ : , https://www.meanwell.com/serviceDisclaimer.aspx<br>Shut down o/p voltage, re-power on to recover<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**PROTECTION**<br>Shut down o/p voltage, re-power on to recover<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>COLD START 50A(twidth=270 s measured at 50% Ipeak) at 230VAC<br>;Per NEMA 410<br>μ<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>17.5 ~ 21V<br>15 ~ 17V<br>23 ~ 27V<br>28 ~ 34V<br>34 ~ 40V<br>41 ~ 46V<br>54 ~ 60V<br>46 ~ 54V<br>59 ~ 66V<br>**NPF-60D-15**<br>**NPF-60D-12**<br>**NPF-60D-20**<br>**NPF-60D-24**<br>**NPF-60D-30**<br>**NPF-60D-36**<br>**NPF-60D-42**<br>**NPF-60D-48**<br>**NPF-60D-54**<br>**TOTAL HARMONIC DISTORTION**<br>I/P-O/P:3.75KVAC<br>I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH<br>**MAX. NO. of PSUs on 16A**<br>**CIRCUIT BREAKER**<br>9 units (circuit breaker of type B) / 16 units (circuit breaker of type C) at 230VAC<br>**SHORT CIRCUIT**<br>Hiccup mode, recovers automatically after fault condition is removed<br>**CURRENT TOLERANCE**<br>±5.0%<br>**CURRENT RIPPLE**<br>5.0% max. @rated current<br>**SET UP TIMENote.3**<br>500ms/115VAC, 230VAC<br>90 ~ 305VAC 127 ~ 431VDC<br>(Please refer to "STATIC CHARACTERISTIC" section)<br> PF≧0.97/115VAC, PF≧0.95/230VAC, PF≧0.92/277VAC@full load<br>(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)<br>THD< 20%(@load≧60%/115VC, 230VAC; @load≧75%/277VAC)<br>(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)<br><0.5W<br>**STANDBY POWER CONSUMPTION**<br>**WORKING TEMP.**<br>Tcase=-40 ~ +85℃(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)<br>**MAX. CASE TEMP.**Tcase=+85℃<br>UL8750(type”HL”), UL879(for 12V,24V only), CSA C22.2 No. 250.13-12, ENEC BS EN/EN61347-1,<br>BS EN/EN61347-2-13, BS EN/EN62384 independent, EAC TP TC 004,GB19510.1,GB19510.14,<br>IP67 approved ; Design refer to BS EN/EN60335-1<br>150*53*35mm (L*W*H)<br>0.49Kg;30pcs/15.7Kg/1.0CUFT<br>60W<br>60W<br>60W<br>60W<br>60W<br>60.12W<br>60W<br>60.48W<br>60.06W<br>9 ~ 15V<br>7.2 ~ 12V<br>12 ~ 20V<br>14.4 ~ 24V<br>18 ~ 30V<br>21.6 ~ 36V<br>28.8 ~ 48V<br>32.4 ~ 54V<br>25.2 ~ 42V<br>4A<br>5A<br>3A<br>2.5A<br>1.67A<br>1.25A<br>1.12A<br>1.43A<br>2A<br>87%<br>86%<br>88%<br>89%<br>90%<br>90%<br>90%<br>90%<br>90%<br>0.8A / 115VAC 0.4A / 230VAC 0.32A / 277VAC|**NPF-60D-12**|**NPF-60D-15**|**NPF-60D-20**|**NPF-60D-24**|**NPF-60D-30**|**NPF-60D-36**|**NPF-60D-42**|**NPF-60D-48**|**NPF-60D-54**| |---|---|---|---|---|---|---|---|---|---|---|---| |||**RATED CURRENT**|5A|4A|3A|2.5A|2A|1.67A|1.43A|1.25A|1.12A| |||**RATED POWER**|60W|60W|60W|60W|60W|60.12W|60.06W|60W|60.48W| |||**CONSTANT CURRENT REGION**|7.2 ~ 12V|9 ~ 15V|12 ~ 20V|14.4 ~ 24V|18 ~ 30V|21.6 ~ 36V|25.2 ~ 42V|28.8 ~ 48V|32.4 ~ 54V| |||**CURRENT RIPPLE**|5.0% max. @rated current||||||||| |||**CURRENT TOLERANCE**|±5.0%||||||||| |||**SET UP TIMENote.3**|500ms/115VAC, 230VAC||||||||| |||**VOLTAGE RANGENote.2**|90 ~ 305VAC 127 ~ 431VDC<br>(Please refer to "STATIC CHARACTERISTIC" section)||||||||| |||**FREQUENCY RANGE**|47 ~ 63Hz||||||||| |||**POWER FACTOR (Typ.)**|PF≧0.97/115VAC, PF≧0.95/230VAC, PF≧0.92/277VAC@full load<br>(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)||||||||| |||**TOTAL HARMONIC DISTORTION**|THD< 20%(@load≧60%/115VC, 230VAC; @load≧75%/277VAC)<br>(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)||||||||| |||**EFFICIENCY(Typ.)**|86%|87%|88%|89%|90%|90%|90%|90%|90%| |||**AC CURRENT (Typ.)**|0.8A / 115VAC 0.4A / 230VAC 0.32A / 277VAC||||||||| |||**INRUSH CURRENT(Typ.)**|COLD START 50A(twidth=270 s measured at 50% Ipeak) at 230VAC<br>;Per NEMA 410<br>μ||||||||| |||**MAX. NO. of PSUs on 16A**<br>**CIRCUIT BREAKER**|9 units (circuit breaker of type B) / 16 units (circuit breaker of type C) at 230VAC||||||||| |||**LEAKAGE CURRENT**|<0.25mA / 277VAC||||||||| |||**STANDBY POWER CONSUMPTION**|<0.5W||||||||| |||**OVER CURRENT**|95 ~ 108%<br>Constant current limiting, recovers automatically after fault condition is removed||||||||| |||**SHORT CIRCUIT**|Hiccup mode, recovers automatically after fault condition is removed||||||||| |||**OVER VOLTAGE**|Shut down o/p voltage, re-power on to recover<br>17.5 ~ 21V<br>15 ~ 17V<br>23 ~ 27V<br>28 ~ 34V<br>34 ~ 40V<br>41 ~ 46V<br>54 ~ 60V<br>46 ~ 54V<br>59 ~ 66V||||||||| |||**OVER TEMPERATURE**|Shut down o/p voltage, re-power on to recover||||||||| |||**WORKING TEMP.**|Tcase=-40 ~ +85℃(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)||||||||| |||**MAX. CASE TEMP.**|Tcase=+85℃||||||||| |||**WORKING HUMIDITY**|20 ~ 95% RH non-condensing||||||||| |||**STORAGE TEMP., HUMIDITY**|-40 ~ +80℃, 10 ~ 95% RH||||||||| |||**TEMP. COEFFICIENT**|±0.03%/℃(0 ~ 50℃)||||||||| |||**VIBRATION**|10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes||||||||| |||**SAFETY STANDARDS**|UL8750(type”HL”), UL879(for 12V,24V only), CSA C22.2 No. 250.13-12, ENEC BS EN/EN61347-1,<br>BS EN/EN61347-2-13, BS EN/EN62384 independent, EAC TP TC 004,GB19510.1,GB19510.14,<br>IP67 approved ; Design refer to BS EN/EN60335-1||||||||| |||**WITHSTAND VOLTAGE**|I/P-O/P:3.75KVAC||||||||| |||**ISOLATION RESISTANCE**|I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH||||||||| |||**EMC EMISSION**|Compliance to<br>@ load≧60%<br>BS EN/EN55015, BS EN/EN61000-3-2 Class C (<br>) ; BS EN/EN61000-3-3;<br>GB17743 and GB17625.1,EAC TP TC 020||||||||| |||**EMC IMMUNITY**|Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN61547, light industry level(surge immunity Line-Line 2KV);<br>EAC TP TC 020||||||||| |||**MTBF**|3082.1K hrs min. Telcordia SR-332 (Bellcore) ; 287.9K hrs min. MIL-HDBK-217F (25℃)||||||||| |||**DIMENSION**|150*53*35mm (L*W*H)||||||||| |||**PACKING**<br>℃<br><br><br><br><br><br>℃<br><br>℃℃<br><br>https://www.meanwell.com/Upload/PDF/LED_EN.pdf<br>※ : , https://www.meanwell.com/serviceDisclaimer.aspx<br>0.49Kg;30pcs/15.7Kg/1.0CUFT|||||||||| _File Name:NPF-60D-SPEC 2022-02-18_ **- NPF 60D series** 60W Single Output LED Driver ## **BLOCK DIAGRAM** **==> picture [468 x 145] intentionally omitted <==** **----- Start of picture text -----**<br> PFC fosc : 50~120KHz<br>PWM fosc : 60~130KHz<br>Vo+<br>EMI FILTER PFC POWER RECTIFIERS Vo-<br>I/P & CIRCUIT SWITCHING &<br>RECTIFIERS FILTER<br>O.L.P. DIM+<br>DIM-<br>O.T.P. O.L.P. DETECTION<br>PWM & PFC CIRCUIT<br>CONTROL<br>O.V.P.<br>**----- End of picture text -----**<br> ## **DRIVING METHODS OF LED MODULE** ※ This series works in constant current mode to directly drive the LEDs. **==> picture [202 x 128] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>Constant<br>Current area<br>60<br>(min.)<br>Hiccup<br>Protection<br>50 100 Io (%)<br>Vo(%)<br>**----- End of picture text -----**<br> In the constant current region, the highest voltage at the output of the driver depends on the configuration of the end systems. Should there be any compatibility issues, please contact MEAN WELL. Typical LED power supply I-V curve _File Name:NPF-60D-SPEC 2022-02-18_ **- NPF 60D series** 60W Single Output LED Driver ## **DIMMING OPERATION** **==> picture [496 x 52] intentionally omitted <==** **----- Start of picture text -----**<br> AC/L(Brown)<br>AC/N(Blue) NPF-60D Vo+(Red)<br>Vo-(Black)<br>DIM+(Purple)<br>DIM-(Pink)<br>**----- End of picture text -----**<br> ## ※ **3 in 1 dimming function** - ‧Output constant current level can be adjusted by applying one of the three methodologies between DIM+ and DIM-: - 0 ~ 10VDC, or 10V PWM signal or resistance. - ‧Direct connecting to LEDs is suggested. It is not suitable to be used with additional drivers. - ‧Dimming source current from power supply: 100μA (typ.) - Applying additive 0 ~ 10VDC **==> picture [215 x 96] intentionally omitted <==** **----- Start of picture text -----**<br> +<br>Vo+ +<br>-<br>Vo- -<br>DIM+<br>+<br>Additive Voltage<br>-<br>DIM-<br>“DO NOT connect "DIM- to Vo-"<br>**----- End of picture text -----**<br> - Applying additive 10V PWM signal (frequency range 100Hz ~ 3KHz): **==> picture [215 x 96] intentionally omitted <==** **----- Start of picture text -----**<br> +<br>Vo+ +<br>-<br>Vo- -<br>DIM+<br>Additive PWM signal<br>DIM-<br>“DO NOT connect "DIM- to Vo-"<br>**----- End of picture text -----**<br> **==> picture [104 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> ◎ Applying additive resistance:<br>**----- End of picture text -----**<br> **==> picture [214 x 96] intentionally omitted <==** **----- Start of picture text -----**<br> +<br>Vo+ +<br>-<br>Vo- -<br>DIM+<br>Additive Resistance<br>DIM-<br>“DO NOT connect "DIM- to Vo-"<br>**----- End of picture text -----**<br> **==> picture [164 x 454] intentionally omitted <==** **----- Start of picture text -----**<br> 100%<br>90%<br>80%<br>70%<br>60%<br>50%<br>40%<br>30%<br>20%<br>10%<br>0%<br>0V 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V<br>Dimming input: Additive voltage<br>100%<br>90%<br>80%<br>70%<br>60%<br>50%<br>40%<br>30%<br>20%<br>10%<br>0%<br>0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>Duty cycle of additive 10V PWM signal dimming input<br>100%<br>90%<br>80%<br>70%<br>60%<br>50%<br>40%<br>30%<br>20%<br>10%<br>0%<br>Short 10K/N 20K/N 30K/N 40K/N 50K/N 60K/N 70K/N 80K/N 90K/N 100K/N<br>(N=driver quantity for�synchronized�dimming operation)<br>Dimming input: Additive resistance<br>Output current (%)<br>Output current (%)<br>Output current (%)<br>**----- End of picture text -----**<br> Note : 1. Min. dimming level is about 6% and the output current is not defined when 0%< Iout<6%. 2. The output current could drop down to 0% when dimming input is about 0kΩ or 0Vdc, or 10V PWM signal with 0% duty cycle. _File Name:NPF-60D-SPEC 2022-02-18_ **- NPF 60D series** 60W Single Output LED Driver ## **OUTPUT LOAD vs TEMPERATURE** **==> picture [499 x 596] intentionally omitted <==** **----- Start of picture text -----**<br> 100 100<br>80 80<br>230VAC 230VAC<br>Input only Input only<br>60 60<br>50<br>40 40<br>20 20<br>-40 -25 -10 0 15 30 50 60 70 (HORIZONTAL) -40 -25 0 20 45 55 65 75 85 (HORIZONTAL)<br>AMBIENT TEMPERATURE,Ta ( � ) Tcase ( � )<br>STATIC CHARACTERISTIC POWER FACTOR (PF) CHARACTERISTIC<br>※ Tcase at 75℃<br>100<br>1.0<br>90<br>0.9<br>80<br>0.8<br>70 0.7 277V<br>60 0.6 230V<br>115V<br>0.5<br>50<br>0.4<br>40<br>0.3<br>10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>90 100 125 135 145 155 165 175 180 200 230 305 (60W)<br>INPUT VOLTAGE (V) 60Hz<br>LOAD<br>※De-rating is needed under low input voltage.<br>TOTAL HARMONIC DISTORTION (THD) EFFICIENCY vs LOAD<br>NPF-60D series possess superior working efficiency that up to 90% can<br>be reached in field applications.<br>※ 48V Model, Tcase at 75℃ ※ 48V Model, Tcase at 75℃<br>28%<br>26% 92%<br>24%<br>22% 90%<br>20%<br>18% 277VAC 88%<br>16%<br>14% 230VAC 86% 277V<br>12% 115VAC 230V<br>10% 84% 115V<br>8%<br>6% 82%<br>4%<br>2% 80%<br>0%<br>78%<br>50% 60% 70% 80% 90% 100%<br>10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>LOAD LOAD<br>LOAD (%) LOAD (%)<br>PF<br>LOAD (%)<br>THD<br>EFFICIENCY(%)<br>**----- End of picture text -----**<br> _File Name:NPF-60D-SPEC 2022-02-18_ **- NPF 60D series** 60W Single Output LED Driver ## **LIFE TIME** **==> picture [361 x 210] intentionally omitted <==** **----- Start of picture text -----**<br> 120<br>100<br>80<br>60<br>40<br>20<br>0<br>25 30 35 40 45 50 55 60 65 70 75 80 85<br>Tcase(℃)<br>(Kh)<br>LIFETIME<br>**----- End of picture text -----**<br> _File Name:NPF-60D-SPEC 2022-02-18_ **==> picture [151 x 12] intentionally omitted <==** **----- Start of picture text -----**<br> 60W Single Output LED Driver<br>**----- End of picture text -----**<br> ## **- NPF 60D series** **==> picture [511 x 668] intentionally omitted <==** **----- Start of picture text -----**<br> MECHANICAL SPECIFICATION Case No. NPF-60A Unit:mm<br>150<br>5<br>300±20<br>AC/L(Brown) 300±20<br>AC/N(Blue) Vo+(Red)<br>Vo-(Black)<br>SJTW 18AWG×2C ψ4.5 35 DIM+(Purple)<br>tc UL2464 18AWG×2C(Vo+,Vo-) DIM-(Pink)<br>UL2464 22AWG×2C(DIM+,DIM-)<br>5<br>‧ : Max. Case Temperaturetc<br>Recommend Mounting Direction<br>INSTALLATION MANUAL<br>Please refer to:http://www.meanwell.com/manual.html<br>5<br>53<br>5 31<br>35<br>3<br>**----- End of picture text -----**<br> _File Name:NPF-60D-SPEC 2022-02-18_
Updated at April 17, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →