Image not available
Illustrative purposes only
NPC38-12
Rechargeable Battery, NP Series, Valve Regulated, Single Cell, 12 V, Lead Acid, 38 Ah, Bolt, 1
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: YUASA
- Product type: Batteries - Rechargeable
- Battery Voltage:12V; Battery Technology:Lead Acid; Battery Capacity:38Ah; Battery Size Code:-; Battery Terminals:Bolt; External Diameter:-; External Height:170mm; External Width:165mm; Externa
- Weight: 14kg
- Pack Quantity: 1
- Product Range: NPC Series
- External Depth: 197mm
- External Width: 165mm
- Battery Voltage: 12V
- External Height: 170mm
- Battery Capacity: 38Ah
- Battery IEC Code: -
- Battery NEDA Code: -
- Battery Size Code: -
- Battery Terminals: Bolt
- Battery Compliance: -
- Battery Technology: Lead Acid
- Battery Type / Size: Lead-Acid
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 185.41 € |
| Current stock | 10+ |
| Lead time | 28 days |
## **NPC-Series - Valve Regulated Lead Acid Battery** ## **NPC38-12I** |SPECIFICATIONS<br>~~Ce~~|||||| |---|---|---|---|---|---| |Nominal voltage<br>12<br>V|||||| |20-hr rate Capacityto 10.5V at 20°C<br>38<br>Ah|||||| |10-hr rate Capacity to 10.8V at 20°C<br>33.44<br>Ah|||||| |DIMENSIONS|||||| |Length<br>197(±0.5)<br>mm<br>Width<br>165(±0.5)<br>mm<br>Height<br>170(±0.5)<br>mm<br>(height over terminals)<br>N/A<br>mm<br>~~a~~<br>~~a~~<br>~~i~~||w|ee<br> YUASA||| |Mass(typical)<br>14.0<br>kg|||||| |TERMINAL TYPE|||||| |Female threaded terminal<br>M5<br>mm|||||| |Torque<br>2.5<br>Nm|||||| |OPERATING TEMPERATURE RANGE|||||| |Storage<br>-20°C to +60°C<br>~~a~~|||||| |Charge<br>-15°C to +50°C<br>~~a~~|||||| |Discharge<br>Capacity loss per month at 20°C (approx)<br>3<br>%<br>Standard Option<br>Flame retardant option (FR)<br>13.65(±1%)<br>V<br>2.275(±1%)<br>V/cell<br>Float Charge voltage temperature correction factor<br>(for variations from the standard 20°C)<br>-3<br>mV/cell/°C<br>14.5(±3%)<br>V<br>2.42(±3%)<br>V/cell<br>Cyclic Charge voltage temperature correction factor<br>(for variations from the standard 20°C)<br>-4<br>mV/cell/°C<br>Float charge current limit<br>No limit<br>A<br>Cyclic (or Boost) charge current limit<br>9.50<br>A<br>1 second<br>500<br>A<br>CHARGE VOLTAGE<br>Float charge voltage at 20°C<br>Cyclic (or Boost) charge at 20°C<br>CHARGE CURRENT<br>MAXIMUM DISCHARGE CURRENT<br>-20°C to +60°C<br>ABS (UL.94:HB)<br>N/A<br>STORAGE<br>CASE MATERIAL<br>~~a~~<br>~~Cn~~~~**a**~~<br>~~Cna~~<br>~~a~~<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~Cn~~<br>~~nn~~<br>~~Cn~~<br>~~nn~~|LAYOUT<br>Ed||||| |1 minute<br>380<br>A<br>Internal resistance<br>N/A<br>mΩ<br>Short-Circuit current<br>N/A<br>A<br>SHORT-CIRCUIT CURRENT & INTERNAL RESISTANCE<br>**(according to EN IEC 60896-21)**<br>CYCLIC LIFE DATA<br>~~a~~<br>~~——~~<br>~~ee~~<br>~~a~~<br>~~ee~~||**3RD PARTY CERTIFICATIONS**<br>ISO 9001 - Quality Management Systems<br>ISO 14001 - Environmental Management Systems<br>EN 18001 - OHSAS Management Systems<br>ISO 9001 - Quality Management Systems||rs<br>‘|| |100% DOD down to 80% capacity<br>300<br>cycles|||||| |75% DOD down to 80% capacity<br>500<br>cycles|||||| |50% DOD down to 80% capacity<br>600<br>cycles<br>~~a~~|||||| |25% DOD down to 80% capacity<br>1400<br>cycles<br>~~a~~|||||| |IMPEDANCE<br>~~ee~~||UNDERWRITERS LABORATORIES Inc.|||| |Measured at 1 kHz<br>7.3<br>mΩ<br>~~a~~|||||| |Refer to the technical manual<br>NPC<br>DESIGN LIFE<br>PERFORMANCE & CHARACTERISTICS<br>~~Ce~~<br>~~a~~<br>~~(~~<br>~~Pe~~||**STANDARDS**<br>IEC61056|||| |EUROBAT Classification: Standard Commercial Cycle<br>Life data: e.g. 600 cycles at 50% DOD<br>3 to 5<br>years|||||| |Can be installed and operated in anyorientation exceptpermanentlyinverted<br>**Installation**<br>SAFETY<br>~~CCL)~~|||||| |**Handles**|||||| |Batteries must not be suspended bytheir handles(where fitted)||ALL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE|||| |**Vent valves**||Issue No.: V.1 / Issue Date: July 2010|Issue No.: V.1 / Issue Date: July 2010||| |Each cell is fitted with a low pressure release valve to allow gasses to escape and then reseal.|||||| |**Gas Release**|||||| |VRLA Batteries release hydrogen gas which can form explosive mixtures in air. Do not place inside a sealed|||||| |container|||||| ## **Recycling** YUASA's VRLA batteries must be recycled at the end of life in accordance with local and national laws and regulations
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →