NLP40-7605J
AC/DC Open Frame Power Supply (PSU), ITE, 1 Output, 50W @ 20CFM, 40 W, 90V AC to 264V AC, Fixed
- Manufacturer: ARTESYN EMBEDDED TECHNOLOGIES
- Product type: AC / DC Open Frame Power Supplies
- Product Range: NLP40
- No. of Outputs: 1 Output
- Output Power Max: 40W
- Input Voltage VAC: 90V AC to 264V AC
- Input Voltage AC Max: 264V
- Input Voltage AC Min: 90V
- Power Supply Approvals: ITE
- Power Supply Output Type: Fixed
- Output Current - Output 1: 8A
- Output Voltage - Output 1: 5VDC
- Power Rating (Forced Cooling): 50W @ 20CFM
- Power Rating (Convection Cooling): 40W
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 24.78 € |
| Current stock | 10+ |
| Lead time | 7 days |
## _NLP40 Series S i n g l e , d u a l a n d t r i p l e o u t p u t_ LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 40-50 W AC/DC Universal Input Switch Mode Power Supplies **1** - **4.25 x 2.5 x 1.15 inch package (1U applications)** - **Smallest industry package** - **Overvoltage and short circuit protection** - **40 W with free air convection** - **EN55022, EN55011 conducted emission level B** - **EN61000-4-2, -3, -4, -5, -6 immunity compliant** - **UL, VDE and CSA safety approvals** ## **• Available RoHS compliant** The NLP40 series is a 40 W universal input ac-dc power supply on a 4.25 x 2.5 inch card with a maximum component height of 1.15 inches for use in 1U applications. This product is the smallest standard 40 W package in the industry making the series ideal for communication applications with space constraints where a standard 5 x 3 inch card solution is not suitable. The NLP40 provides 40 W of output power with free air convection cooling which can be boosted to 50 W with 20 CFM of air. Standard features include overvoltage and short circuit protection. The series, with full international safety approval and the CE mark, meets conducted noise EN55022 level B and has immunity compliance to EN61000-4-2,-3,-4, -5, -6. The NLP40 series is designed for use in low power data networking, computer and telecom applications such as hubs, routers, POS terminals, LCD projectors, cable modems and PABX’s. This list is not exclusive as the generic feature set of the NLP40 series with industry standard output configurations provides a solution for most low power applications including many industrial applications. ## **2 YEAR WARRANTY** |**_All specifications are typical at nominal input, full load at 25 °C unless otherwise stated_**|**_SPECIFICATIONS_**|**_SPECIFICATIONS_**|**_SPECIFICATIONS_**| |---|---|---|---| ||||| |GENERAL SPECIFICATIONS|||| |Hold-up time|120 Vac||12 ms @ 40 W| ||230 Vac||20 ms @ 40 W| |Efficiency|||75% typical| |Isolation voltage|Input/output||3000 Vac| ||Input/chassis||1500 Vac| |Switching frequency|Fixed||65 kHz, ±5 kHz| |Approvals and|EN60950, IEC950, UL1950||| |standards (See Note 8)|VDE0805, CSA C22.2 No. 950|VDE0805, CSA C22.2 No. 950|| |Weight|||200 g (7.06 oz)| |MTBF|MIL-HDBK-217F|150,000 hours min.|| |ENVIRONMENTAL SPECIFICATIONS|||| |Thermal performance|Operating ambient,||0 °C to +70 °C| |(See Notes 6, 7, 9)|(see derating curve)||| ||Non-operating<br>-40 °C to +70 °C<br>50 °C to 70 °C ambient,<br>Derate to||| ||convection cooled||50% load| ||0 °C to 50 °C, ambient,||40 W| ||convection cooled||| ||0 °C to 50 °C ambient,<br>20 CFM forced air||50 W| ||Peak (0 °C to +50 °C, 60 s)||Peak (0 °C to +50 °C, 60 s) (See Note 2)| |Relative humidity|Non-condensing||5% to 95% RH| |Altitude|Operating|10,000 feet max.|| ||Non-operating|30,000 feet max.|| |Vibration (See Note 4)|5-500 Hz||2.4 G rms peak| |Shock|per MIL-STD-810E||516.4 Part IV| ## _**All specifications are typical at nominal input, full load at 25 °C unless otherwise stated**_ |**OUTPUT SPECIFICATIONS**|**OUTPUT SPECIFICATIONS**|| |---|---|---| |Total regulation|Main output|±2.0%| |(Line and load)|Auxiliary outputs|±5.0%| |Rise time|At turn-on|1.0 s, max.| |Transient response|Main output|5.0% max. dev.,| ||25% step at 0.1 A/µs 1 ms rec. to 1.0%|| |Temperature coefficient||±0.02%/°C| |Overvoltage protection|Main outputs|135%, ±15%| |Short circuit protection|Cyclic operation|Continuous| |Minimum output current|Single|0 A| ||Multiple|(See Note 5)| |**INPUT SPECIFICATIONS**||| |Input voltage range|Universal input|90-264 Vac| |(See Note 9)||120-370 Vdc| |Input frequency range||47-440 Hz| |Input surge current|120 Vac, cold start|15 A max.| ||230 Vac, cold start|30 A max.| |Safety ground|120 Vac, 60 Hz|0.2 mA| |leakage current|230 Vac, 50 Hz|0.4 mA| |Input current|120 Vac|1.4 A rms| ||230 Vac|0.7 A rms| |Input fuse|UL/IEC127|250 Vac H 3.15 A| |EMC CHARACTERISTICS**(10)**||| |Conducted emissions|EN55022, FCC part 15|level B| |Radiated emissions|EN55022, FCC part 15|level A| |ESD air|EN61000-4-2, level 3|Perf. criteria 1| |ESD contact|EN61000-4-2, level 3|Perf. criteria 1| |Surge|EN61000-4-5, level 3|Perf. criteria 1| |Fast transients|EN61000-4-4, level 3|Perf. criteria 1| |Radiated immunity|EN61000-4-3, level 3|Perf. criteria 1| |Conducted immunity|EN61000-4-6, level 3|Perf. criteria 1| File Name: nlp40.pdf Rev (03): 08 Nov 2005 ## _NLP40 Series_ ## _S i n g l e , d u a l a n d t r i p l e o u t p u t_ **==> picture [171 x 47] intentionally omitted <==** **==> picture [512 x 45] intentionally omitted <==** **----- Start of picture text -----**<br> LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 40-50 W AC/DC Universal Input Switch Mode Power Supplies 2<br>For the most current data and application support visit www.artesyn.com/powergroup/products.htm<br>**----- End of picture text -----**<br> |**OUTPUT**<br>**VOLTAGE**|**OUTPUT CURRENT**|**OUTPUT CURRENT**|**OUTPUT CURRENT**|**RIPPLE (3)**|**TOTAL**<br>**REGULATION**|**MODEL NUMBER (11,12)**| |---|---|---|---|---|---|---| ||**MAX (1)**|**PEAK (2)**|**FAN (1)**|||| |+3.3 V (IA)|4 A|5 A|4.5 A|50 mV|±2.0%|NLP40-76T366J (5)| |+12 V (IB)|2 A|3 A|3 A|120 mV|±5.0%|| |–12 V (IC)|0.2 A|1 A|0.5 A|120 mV|±5.0%|| |+5 V (IA)|4 A|5 A|4.5 A|50 mV|±2.0%|NLP40-7608J (5)| |+12 V (IB)|2 A|3 A|3 A|120 mV|±5.0%|| |–12 V (IC)|0.2 A|1 A|0.5 A|120 mV|±5.0%|| |+5 V (IA)|4 A|5 A|4.5 A|50 mV|±2.0%|NLP40-7610J (5)| |+15 V (IB)|1.6 A|2 A|2 A|150 mV|±5.0%|| |–15 V (IC)|0.2 A|1 A|0.5 A|150 mV|±5.0%|| |+12 V (IA)|1.8 A|2.2 A|2.1 A|120 mV|±2.0%|NLP40-7627J (5)| |-12 V (IB)|1.8 A|2.2 A|2.1 A|120 mV|±5.0%|| |+5 V (IA)|4 A|5 A|4.5 A|50 mV|±2.0%|NLP40-7629J (5)| |+12 V (IB)|2 A|3 A|3 A|120 mV|±5.0%|| |3.3 V (IA)|8 A|10 A|9 A|50 mV|±2.0%|NLP40-76S3J| |5 V|8 A|10 A|9 A|50 mV|±2.0%|NLP40-7605J| |12 V|3.3 A|4.5 A|4 A|120 mV|±2.0%|NLP40-7612J| |15 V|2.6 A|3.6 A|3.3 A|150 mV|±2.0%|NLP40-7615J| |24 V|1.6 A|2.5 A|2 A|240 mV|±2.0%|NLP40-7624J| |48 V|0.8 A|1.1 A|1 A|300 mV|±2.0%|NLP40-7617J| ## **Notes** - **1** Maximum output power is 40 W for natural convection cooling. With 20 CFM fan cooling, the maximum output power is 50 W. - **2** Peak output current lasting less than 60 seconds with duty cycle less than 5%. During peak loading, output voltage may exceed total reg. limits. - **3** Figure is peak-to-peak. Output noise measurements are made across a 50 MHz bandwidth using a 12 inch twisted pair, terminated with a 47 µF capacitor. - **4** Three orthogonal axes, random vibration 10 minutes for each axes, 2.4 G rms 5 Hz to 500 Hz. - **5** For multiple output units (except -7627J, 76T366J) to maintain stated regulation then: - 0.25 ≤IA / IB ≤5, for IB > 0.3 A - 0.50 ≤IA / IB ≤5, for IB < 0.3 A For maximum output current I(C) on triple output models, i.e. for - IC = IMax., I A min. ≥0.5 A and IA ≥IB. For NLP40-7627J only, to maintain stated regulation then: - 0.5 ≤IA / IB ≤2. For NLP40-76T366J only, to maintain stated regulation then: - 0.25 ≤IA / IB ≤4. - **6** For optimum reliability, no part of the heatsink should exceed 120 °C, and no semiconductor case temperature should exceed 130 °C. - **7** CAUTION: Allow a minimum of 1 second after disconnecting line power when making thermal measurements. **==> picture [250 x 190] intentionally omitted <==** **----- Start of picture text -----**<br> DERATING CURVE<br>Output Power (Watts)<br>50W<br>20 CFM FORCED AIR COOLING<br>40W<br>NATURAL 25W<br>CONVECTION 20W<br>COOLING<br>0 ° C 10 ° C 20 ° C 30 ° C 40 ° C 50 ° C 60 ° C 70 ° C<br>**----- End of picture text -----**<br> - **8** This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. - **9** When the input voltage is <90 Vac the operating range is 0 °C to +40 °C. - **10** For system EMI compliance, a ground choke may be required before connecting the ground wire to the chassis. It is recommended that this ground choke be placed as close as possible to the systems ac inlet to eliminate noise pick-up in the system. - **11** The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant. TSE RoHS 5/6 (non Pb-free) compliant versions may be available on special request, please contact your local sales representative for details. - **12** NOTICE: Some models do not support all options. Please contact your local Artesyn representative or use the on-line model number search tool at http://www.artesyn.com/powergroup/products.htm to find a suitable alternative. File Name: nlp40.pdf Rev (03): 08 Nov 2005 _NLP40 Series S i n g l e , d u a l a n d t r i p l e o u t p u t_ **==> picture [511 x 298] intentionally omitted <==** **----- Start of picture text -----**<br> LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 40-50 W AC/DC Universal Input Switch Mode Power Supplies 3<br>For the most current data and application support visit www.artesyn.com/powergroup/products.htm<br>|<br>4.25<br>(107.95)<br>4.00 0.125<br>(101.60) (3.175)<br>J1<br>F1<br>N<br>1<br>L<br>2.50 2.25<br>(63.50) J2 (57.15)<br>P1<br>T1<br>C5<br>Fai ie |<br>MAXIMUM COMPONENT Mounting<br>HEIGHT 1.15 (29.21) Hole Diameter<br>ALL DIMENSIONS IN INCHES (mm) TOLERANCE: .xxx ± 0.005" 0.138 (3.50) Typical<br>.xx ± 0.02"<br>**----- End of picture text -----**<br> ## **Input and output connectors** **AC (J1) connector type** Molex 26-60-4030 type. **DC (J2) connector type** Molex 26-60-4060 type. ## **Mating connectors** ## **AC (J1) mating connector type** Molex 09-50-3031 or equivalent with Molex 08-50-0105 or equivalent crimp terminals. **DC (J2) mating connector type** Molex 09-50-3061 with Triurcon 6838 or equivalent crimp terminals. **Note:** The input and output connectors are the same as those used on NFS40, NFN40, NAL40 and NAN40. |**INPUT**| |---| |**PIN CONNECTIONS**| |**J1**| |Pin 1<br>AC Line<br>Pin 2<br>No Pin| |Pin 3<br>AC Neutral| |**P1**| |Pin 1<br>Safety Ground| ## **International Safety Standard Approvals** VDE0805/EN60950/IEC950 File 10401-3336-0093 Licence No. 93662 UL1950 File No. E136005 CSA C22.2 No. 950 File No. LR41062C |||**OUTPUT PIN CONNECTIONS**|**OUTPUT PIN CONNECTIONS**|**OUTPUT PIN CONNECTIONS**| |---|---|---|---|---| |**J2**||**SINGLE**|**DUAL**|**TRIPLE**| |Pin 1|Pin 1|+Vout|V (B)|V (B)| |Pin 2|Pin 2|+Vout|V (A)|V (A)| |Pin 3|Pin 3|+Vout|V (A)|V (A)| |Pin 4|Pin 4|Return|Return|Return| |Pin 5|Pin 5|Return|Return|Return| |Pin 6|Pin 6|Return|Return|V (C)| ## Datasheet © Artesyn Technologies® 2005 The information and specifications contained in this datasheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising from printing errors or inaccuracies. The information and specifications contained or described herein are subject to change in any manner at any time without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein. _**www.artesyn.com**_ File Name: nlp40.pdf Rev (03): 08 Nov 2005
Updated at February 9, 2023
Artesyn Embedded Technologies, now part of Advanced Energy, is a global leader in the design and manufacture of highly reliable embedded power conversion solutions. The company is widely recognised for engineering robust power systems that drive the most demanding applications across hyper-scale data centres, telecom infrastructures, industrial automation, and medical technology. Our extensive range of Artesyn components is heavily focused on power supplies, specifically a broad selection of AC / DC converters. This comprehensive portfolio includes open-frame and enclosed models, configurable modular power supplies, and rack-mounting bulk front-end units. Engineered for exceptional efficiency and safety, these AC / DC power supplies are designed to integrate seamlessly into complex power architectures. Complementing this primary offering, we also feature a targeted selection of Artesyn's DC / DC converters. This includes precision-engineered isolated and non-isolated models available in industry-standard brick form factors, ensuring reliable power delivery and tight voltage regulation for critical board-level and embedded applications.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →