NJ 5-11-N-G
INDUCTIVEPOSITION
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: PEPPERL+FUCHS
- Product type: Inductive Proximity Sensors
- Sensor Output: NAMUR
- Sensing Range Max: 5mm
- Supply Voltage DC Max: 8.2V
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 68.0 € |
| Current stock | 10+ |
| Lead time | 30 days |
**NJ5-11-N-G** **Inductive sensor** ## ~~Pe~~ **Technical Data** CE @s 0102 **Model Number** ee **NJ5-11-N-G** **Features** ee **• 5 mm non-flush** - **Usable up to SIL 2 acc. to IEC 61508** |**General specifications**||| |---|---|---| |Switching function||Normally closed (NC)| |Output type||NAMUR| |Rated operating distance|sn|5 mm| |Installation||non-flush| |Assured operating distance|sa|0 ... 4.05 mm| |Reduction factor rAl||0.4| |Reduction factor rCu||0.3| |Reduction factor r304<br>Output type||0.85<br>2-wire| |**Nominal ratings**||| |Nominal voltage|Uo|8.2 V (Riapprox. 1 kΩ)| |Switching frequency|f|0 ... 3000 Hz| |Hysteresis|H|typ. 5 %| |Suitable for 2:1 technology||yes , Reverse polarity protection diode not required| |Current consumption||| |Measuring plate not detected||≥3 mA| |Measuring plate detected<br>**Functional safety related parameters**<br>Safety Integrity Level (SIL)<br>MTTFd<br>Mission Time (TM)||≤1 mA<br>SIL 2<br>11774 a<br>20 a| |Diagnostic Coverage (DC)||0 %| |**Ambient conditions**<br>Ambient temperature<br>**Mechanical specifications**||-25 ... 100 °C (-13 ... 212 °F)| |Connection type<br>Core cross-section||cable PVC , 2 m<br>0.34 mm2| |Housing material<br>Sensing face<br>Degree of protection<br>Cable||Stainless steel 1.4305 / AISI 303<br>PVDF<br>IP68| |Bending radius||> 10 x cable diameter| |**General information**||| |Use in the hazardous area||see instruction manuals| |**Compliance with standards and**||| |**directives**||| |Standard conformity||| |NAMUR||EN 60947-5-6:2000| |||IEC 60947-5-6:1999| |Standards||EN 60947-5-2:2007| |||EN 60947-5-2/A1:2012| |||IEC 60947-5-2:2007| |||IEC 60947-5-2 AMD 1:2012| |**Approvals and certificates**||| |EAC conformity||TR CU 012/2011| |UL approval||cULus Listed, General Purpose| |CCC approval||CCC approval / markingnot required forproducts rated≤36 V| ~~PO~~ **Dimensions** **==> picture [60 x 88] intentionally omitted <==** **----- Start of picture text -----**<br> M14x1<br>Ø 11<br>19<br>iP |<br>14<br>31<br>3<br>**----- End of picture text -----**<br> Refer to “General Notes Relating to Pepperl+Fuchs Product Information”. ~~CC~~ Pepperl+Fuchs Group USA: +1 330 486 0001 www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com **1** Germany: +49 621 776 4411 Singapore: +65 6779 9091 fa-info@de.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com **NJ5-11-N-G** **Inductive sensor** **Electrical Connection** **==> picture [61 x 38] intentionally omitted <==** **----- Start of picture text -----**<br> BN<br>L+<br>BU<br>L-<br>**----- End of picture text -----**<br> Refer to “General Notes Relating to Pepperl+Fuchs Product Information”. Pepperl+Fuchs Group USA: +1 330 486 0001 Germany: +49 621 776 4411 Singapore: +65 6779 9091 www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@de.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com 2 **NJ5-11-N-G** **Inductive sensor** |**Data for application in connection**|**with hazardous**|| |---|---|---| |**areas**||| |Equipment protection level||Gb , Gc (ic) , Da , Mb| |||| |**Equipment protection level Gb**||| |Type of protection||intrinsic safety| |CE marking||0102| |Certificates||| |Appropriate type||NJ 5-11-N...| |ATEX certificate||PTB 00 ATEX 2048 X| |ATEX marking||¬II 2G Ex ia IIC T6…T1 Gb| |Standards||EN 60079-0:2012+A11:2013 , EN 60079-11:2012| |IECEx certificate||IECEx PTB 11.0037X| |IECEx marking||Ex ia IIC T6...T1 Gb| |Standards||IEC 60079-0:2011 , IEC 60079-11:2011| |Effective internal inductivity|Ci|≤45 nF| |||A cable length of 10 m is considered.| |Effective internal inductance|Li|≤50µH| |||A cable length of 10 m is considered.| |Maximum permissible ambient temperature Tamb||Also observe the maximum permissible ambient temperature stated in the general technical data.| |||Keep to the lower of the two values.| |||at Ui= 16 V , Ii= 25 mA , Pi= 34 mW ,| |||T6 : 72 °C (161.6 °F)| |||T5 : 87 °C (188.6 °F)| |||T4 : 100 °C (212 °F)| |||T3 : 100 °C (212 °F)| |||T2 : 100 °C (212 °F)| |||T1 : 100 °C (212 °F)| |||at Ui= 16 V , Ii= 25 mA , Pi= 64 mW ,| |||T6 : 65 °C (149 °F)| |||T5 : 80 °C (176 °F)| |||T4 : 100 °C (212 °F)| |||T3 : 100 °C (212 °F)| |||T2 : 100 °C (212 °F)| |||T1 : 100 °C (212 °F)| |||at Ui= 16 V , Ii= 52 mA , Pi= 169 mW ,| |||T6 : 42 °C (107.6 °F)| |||T5 : 57 °C (134.6 °F)| |||T4 : 82 °C (179.6 °F)| |||T3 : 82 °C (179.6 °F)| |||T2 : 82 °C (179.6 °F)| |||T1 : 82 °C (179.6 °F)| |||at Ui= 16 V , Ii= 76 mA , Pi= 242 mW ,| |||T6 : 26 °C (78.8 °F)| |||T5 : 41 °C (105.8 °F)| |||T4 : 63 °C (145.4 °F)| |||T3 : 63 °C (145.4 °F)| |||T2 : 63 °C (145.4 °F)| |||T1 : 63 °C (145.4 °F)| Refer to “General Notes Relating to Pepperl+Fuchs Product Information”. Pepperl+Fuchs Group USA: +1 330 486 0001 Germany: +49 621 776 4411 Singapore: +65 6779 9091 www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@de.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com **3** **NJ5-11-N-G** **Inductive sensor** |**Equipment protection level Gc (ic)**||||||| |---|---|---|---|---|---|---| |Type of protection<br>CE marking||intrinsic safety||||| |Certificates||||||| |ATEX certificate||PF||13 CERT 2895 X||| |ATEX marking||¬|||II 3G Ex ic IIC T6…T1 Gc|| |Standards||EN 60079-0:2012+A11:2013 , EN 60079-11:2012||||| |Effective internal inductivity|Ci|≤|45|||nF| |||A|cable length of 10 m is considered.|||| |Effective internal inductance|Li|≤|50|||µH| |||A|cable length of 10 m is considered.|||| |Maximum permissible ambient temperature Tamb||Also||||observe the maximum permissible ambient temperature stated in the general technical data.| |||Keep to the lower of the two values.||||| |||at Ui||||= 20 V , Ii= 25 mA , Pi= 34 mW ,| |||T6||:|55 °C (131 °F)|| |||T5||:|55 °C (131 °F)|| |||T4||:|55 °C (131 °F)|| |||T3||:|55 °C (131 °F)|| |||T2||:|55 °C (131 °F)|| |||T1||:|55 °C (131 °F)|| |||at Ui||||= 20 V , Ii= 25 mA , Pi= 64 mW ,| |||T6||:|55 °C (131 °F)|| |||T5||:|55 °C (131 °F)|| |||T4||:|55 °C (131 °F)|| |||T3||:|55 °C (131 °F)|| |||T2||:|55 °C (131 °F)|| |||T1||:|55 °C (131 °F)|| |||at Ui||||= 20 V , Ii= 52 mA , Pi= 169 mW ,| |||T6||:|32 °C (89.6 °F)|| |||T5||:|32 °C (89.6 °F)|| |||T4||:|32 °C (89.6 °F)|| |||T3||:|32 °C (89.6 °F)|| |||T2||:|32 °C (89.6 °F)|| |||T1||:|32 °C (89.6 °F)|| |||at Ui||||= 20 V , Ii= 76 mA , Pi= 242 mW ,| |||T6||:|16 °C (60.8 °F)|| |||T5||:|16 °C (60.8 °F)|| |||T4||:|16 °C (60.8 °F)|| |||T3||:|16 °C (60.8 °F)|| |||T2||:|16 °C (60.8 °F)|| |||T1||:|16 °C (60.8 °F)|| |||,,,<br>T6 : 16 °C (60.8 °F)<br>T5 : 16 °C (60.8 °F)<br>T4 : 16 °C (60.8 °F)<br>T3 : 16 °C (60.8 °F)<br>T2 : 16 °C (60.8 °F)<br>T1 : 16 °C (60.8 °F)|| |---|---|---|---| |**Equipment protection level Da**|||| |Type of protection||intrinsic safety|| |CE marking||0102|| |Certificates|||| |Appropriate type||NJ 5-11-N...|| |ATEX certificate||PTB 00 ATEX 2048 X|| |ATEX marking||¬II 1D Ex ia IIIC T135°C Da|| |Standards||EN 60079-0:2012+A11:2013 , EN 60079-11:2012|| |IECEx certificate||IECEx PTB 11.0037X|| |IECEx marking||Ex ia IIIC T135°C Da|| |Standards||IEC 60079-0:2011 , IEC 60079-11:2011|| |Effective internal inductivity|Ci|≤45 nF|| |||A cable length of 10 m is considered.|| |Effective internal inductance|Li|≤50µH|| |||A cable length of 10 m is considered.|| |Maximum permissible ambient temperature Tamb||Also observe the maximum permissible ambient temperature stated in the general technical data.|| |||Keep to the lower of the two values.|| |||at Ui= 16 V , Ii= 25 mA , Pi= 34 mW : 100 °C (212 °F)|| |||at Ui= 16 V , Ii= 25 mA , Pi= 64 mW : 100 °C (212 °F)|| |**Equipment protection level Mb**<br>Certificates<br>Appropriate type||at Ui= 16 V , Ii= 52 mA , Pi= 169 mW : 82 °C (179.6 °F)<br>at Ui= 16 V , Ii= 76 mA , Pi= 242 mW : 63 °C (145.4 °F)<br>NJ 5-11-N...|306130_eng.xml| |IECEx certificate<br>IECEx marking<br>Standards<br>Effective internal inductivity<br>Ci<br>Effective internal inductance<br>Li<br>Maximum permissible ambient temperature Tamb||IECEx PTB 11.0037X<br>Ex ia I Mb<br>IEC 60079-0:2011 , IEC 60079-11:2011<br>≤45 nF<br>A cable length of 10 m is considered.<br>≤50µH<br>A cable length of 10 m is considered.<br>Also observe the maximum permissible ambient temperature stated in the general technical data.|Date of issue: 2018-04-19| |||Keep to the lower of the two values.<br>at Ui= 16 V , Ii= 25 mA , Pi= 34 mW : 100 °C (212 °F)<br>at Ui= 16 V , Ii= 25 mA , Pi= 64 mW : 100 °C (212 °F)<br>at Ui= 16 V , Ii= 52 mA , Pi= 169 mW : 82 °C (179.6 °F)<br>at Ui= 16 V , Ii= 76 mA , Pi= 242 mW : 63 °C (145.4 °F)|Release date: 2018-04-19 08:21| Refer to “General Notes Relating to Pepperl+Fuchs Product Information”. Pepperl+Fuchs Group USA: +1 330 486 0001 Germany: +49 621 776 4411 Singapore: +65 6779 9091 www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@de.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com 4
Updated at February 9, 2023
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →