NHB4-0N
Base Unit, LR4 Series Network Signal Tower, NHB4 Series
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: PATLITE
- Product type: Signal Indicator Accessories
- SVHC: No SVHC (27-Jun-2024)
- For Use With: Patlite LR4 Series Network Signal Towers
- Product Range: NHB4 Series
- Accessory Type: Base Unit
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 725.75 € |
| Current stock | 10+ |
| Lead time | 30 days |
Drawing No. Rev. Page NHB6-3- W 18 E 1 / 10 ## **SPECIFICATIONS** Product Name : Network Signal Tower - - Model : NHB□ □□ □□□□□ |Drawing No.|Rev.|Page| |---|---|---| |NHB6-3-W18|E|2 / 10| ## **1. General Specifications** |NHB□-5□<br>5 tiers<br>a| |---| |NHB□-4□<br>4 tiers<br>a| |2 tiers<br>Model<br>NHB□-3□<br>NHB□-2□<br>3 tiers<br>a<br>a| |1 tier<br>NHB□-1□<br>a| |0 tiers<br>Operating Ambient Temperature<br>Main Unit*2<br>LED Unit<br>21.6 - 26.4VDC<br>90 - 264VAC<br>1.0W (per Unit, with AC Adaptor, 100VAC input)<br>0 - 40℃(No Dew or Condensation)<br>Rated Power<br>Consumption<br>Standby: 110mA Maximum: 155mA (24VDC input)<br>40mA (per Unit)<br>DC Jack<br>AC Adaptor*1<br>Standby: 3.2W Maximum: 4.4W (with AC Adaptor, 100VAC input)<br>Rated Current<br>Consumption<br>Main Unit*2<br>LED Unit<br>Operating<br>Voltage Range<br>DC Jack<br>Input: 100 - 240VAC (50/60Hz) Output: 24VDC<br>NHB□-0□<br>24VDC<br>Rated Voltage<br>AC Adaptor*1<br>a<br>_——_—————<br>a<br>_—_————<br>a<br>Oe<br>esee<br>a<br>_——_—————<br>a<br>es| |Operating Ambient Humidity<br>20%RH - 80%RH (No Dew or Condensation)<br>ee| |Storage Ambient Temperature<br>-10 - 60℃(No Dew or Condensation)<br>es| |Storage Ambient Humidity<br>20%RH - 80%RH (No Dew or Condensation)<br>ee| |Mounting Location<br>Indoor Only<br>es| |Mounting Direction<br>Upright<br>ee| |Protection Rating<br>IP 20<br>es| |Insulation Resistance<br>More than 10Mohm at 500VDC between live part and non-current carrying metallic part<br>ee| |Mass<br>[Tolerance±10%]<br>Withstand Voltage<br>Environmental Condition<br>1500VAC applied for 1min (10mA or less) between live part and non-current carrying<br>metallic part without breaking insulration<br>Ethernet (Conforms to the IEEE 802.3)<br>10BASE-T / 100BASE-TX / 1000BASE-T (Auto MDI / MDI-X)<br>IPv4 / IPv6 dual stack<br>Interface<br>USB2.0/1.1 Type-A 1ch<br>IP Network<br>635g + (35g) x Signal Tower Tiers (AC Adaptor not included)<br>NHB4<br>Communication Method<br>Front direction from the center, at 1m, Maximum volume setting<br>645g + (60g) x Signal Tower Tiers (AC Adaptor not included)<br>NHB6<br>Sound Pressure Level<br>80dB or more (at 25℃)<br>————————————————<br>es<br>_——_—————<br>a<br>yee<br>ee| |Outer Dimensions<br>Refer to the Outer Dimension Drawing<br>es| |Accessories<br>AC Adaptor*1 , Adhesive sheet<br>ee| |LR6-E-RZ, RY, RG, RB, C<br>LR4-E-RZ, RY, RG, RB, C<br>Wall Mounting Bracket<br>NH-001<br>LR6-E-R, Y, G, B, MZ<br>Wireless Data Acquisition System Transmitter<br>WDT-6LR-Z2<br>Wireless Data Acquisition System Transmitter<br>Optional Parts<br>Partition Mounting Bracket<br>NH-002<br>AC Adaptor<br>ADP-001<br>WDT-4LR-Z2<br>NHB4<br>Compatible Unit<br>(Optional)<br>LR4-E-R, Y, G, B<br>LED Unit<br>NHB6<br>LED Unit<br>_Eee<br>BRa<br>ee| > Drawing No. Rev. Page > NHB6-3-W18 E 3 / 10 UL 62368-1, CSA C22.2 No.62368-1 FCC Part 15 Subpart B(Class A), ICES-003(Class A) Conformity Standards EN 55032(Class A), EN 55035, EN IEC 63000 (KS C 9610-6-4, KS C 9610-6-2) *3 (TR CU 020, TR EEU 037) *3 *1 N type excluded *2 This value excludes USB current consumption. Remark *3 Only N type ・ ・ Conforms to the CE Requirements Conforms to the UKCA Requirements ・ UL/cUL Listed — **2. Model** 2.1. Model Number Configuration - - N H B □ □ □ □□□□ □ Signal Tower Type Signal Tower Tiers AC Adaptor LED Unit Color 6 LR6(φ60) 0 0 tiers Blank AC Adaptor included R Red 4 LR4(φ40) 1 1 tier N AC Adaptor not included Y Amber 2 2 tiers G Green 3 3 tiers B Blue 4 4 tiers C White ~~Sa~~ 5 5 tiers From top to bottom 2.2. Model Number List NHB4-0 NHB4-3-RYG NHB6-0 NHB6-3-RYG NHB4-0N NHB4-3N-RYG NHB6-0N NHB6-3N-RYG NHB4-1-R NHB4-4-RYGB NHB6-1-R NHB6-4-RYGB NHB4-1-Y NHB4-5-RYGBC NHB6-1-Y NHB6-5-RYGBC NHB4-1-G NHB6-1-G NHB4-2-RY NHB6-2-RY NHB4-2-RG NHB6-2-RG ~~oe~~ Drawing No. Rev. Page NHB6-3-W18 E 4 / 10 rtf **3. Action Specification** 3.1. Information (Main Unit) **Signal Tower Lighting, Flashing pattern, and off lighting can be controlled for each LED.** Flashing pattern 1 ON(500ms), OFF(500ms) (repetition) Flashing pattern 2 ON(80ms), OFF(170ms), ON(80ms), OFF(670ms) (repetition) Flashing pattern 3 ON(250ms), OFF(250ms) (repetition) Flashing pattern 4 ON(1000ms), OFF(1000ms) (repetition) **Buzzer 5 kinds of buzzer sounds** Buzzer pattern 1 ON(250ms), OFF(250ms) (repetition) Buzzer pattern 2 ON(500ms), OFF(500ms) (repetition) Buzzer pattern 3 ON(200ms), OFF(50ms), ON(200ms), OFF(550ms) (repetition) Buzzer pattern 4 ON(continuity) =ESS Buzzer pattern 5 ON(1000ms), OFF(1000ms) (repetition) = 3.2. Information (Network) **Email Notification When an event occurs, an e-mail message is transmitted** Number of notifications 8 Authentication protocol SMTP certification(Password, OAuth2), POP authentication Security SSL/TLS, STARTTLS, none **SNMP Notification When an event occurs, Trap or Inform is executed.** Number of notifications 8 — Version v1 / v2c / v3 **HTTP Notification When an event occurs, HTTP command is executed.** Number of notifications 8 Protocol HTTP, HTTPS Method GET an Authentication protocol Basic Access Authentication, Digest Access Authentication, none i[=SSSSS==] **4. Function Specification** 4.1. Main Unit Control Function RSH Command Controllable with RSH Command SSH Command Controllable with SSH Command HTTP Command Controllable with HTTP Command Socket Communication Controllable with PNS Command and PHN Command SNMP Command Controllable with SNMP "set" Command Version v1 / v2c / v3 po "Clear"Button Clear operation is possible with "Clear" Button of the main unit > Drawing No. Rev. Page > NHB6-3-W18 E 5 / 10 rTii **==> picture [407 x 134] intentionally omitted <==** **----- Start of picture text -----**<br> Controllable Action<br>Command Signal Tower Buzzer e-mail SNMP HTTP<br>RSH Command ✓ ✓ ✓*1 ✓*1 -<br>SSH Command ✓ ✓ ✓*1 ✓*1 -<br>HTTP Command ✓ ✓ - - -<br>PNS ✓ ✓ - - -<br>Socket<br>PHN △*2 △*3 - - -<br>SNMP Command ✓ ✓ - - -<br>"Clear"Button ✓ ✓*4 ✓ ✓ ✓<br>*1 It can be used when e-mail or SNMP is set to "Active" in the RSH/SSH Command Configuration.<br>**----- End of picture text -----**<br> - *2 Signal Tower "Red", "Amber" and "Green", and Flashing pattern 1 - *3 Buzzer pattern1 and Buzzer pattern2 - *4 It is possible to stop only the buzzer while maintaining the state of Signal Tower. **==> picture [493 x 364] intentionally omitted <==** **----- Start of picture text -----**<br> 4.2. External Monitoring Function<br>Ping Monitoring Function Network abnormality detection by sending Ping network devices<br>Number of Monitoring 24<br>Number of Group 3<br>Monitoring Cycle 1 - 600 seconds<br>Sending Count The number of times to detect can be set from 1 to 30.<br>== Number of Sending The number of sending Ping by one monitoring can be set from 1 to 3.<br>SNMP Trap Reception Function Trap Reception detection<br>Version v1 / v2c / v3<br>Number of Reception 64<br>variable-bindings 2 OID per 1 Trap Reception<br>EST Detectable Type INTEGER, OCTET STRING (String data, Binary data)<br>SNMP Supported Equipment For SNMP Supported equipment, with SNMP command,<br>Monitor Function their status can be acquisitioned periodically and monitored.<br>Version v1 / v2c / v3<br>Monitoring Cycle 1 - 60 seconds<br>Detection method Condition Agreement Detection : 20 Change Detection : 5<br>Condition Agreement Dtection that the acquired value meets the condition<br>Detectable Type INTEGER, OCTET STRING (String data, Binary data)<br>Change Detection Detection that the acquired value has changed<br>(= Detectable Type SS INTEGER<br>Executable action at detection<br>Monitoring Signal Tower Buzzer e-mail SNMP HTTP MQTT<br>Ping Monitoring ✓ ✓ ✓ ✓ ✓ ✓<br>SNMP Trap Reception ✓ ✓ ✓ ✓ ✓ ✓<br>SNMP Supported ✓ ✓ ✓ ✓ ✓ ✓<br>**----- End of picture text -----**<br> > Drawing No. Rev. Page > NHB6-3-W18 E 6 / 10 it ## 4.3. Main Unit Status Acquisition Function |RSH Command|||The state of the main body can be acquired by the status acquisition command.|The state of the main body can be acquired by the status acquisition command.|The state of the main body can be acquired by the status acquisition command.|The state of the main body can be acquired by the status acquisition command.| |---|---|---|---|---|---|---| |SSH Command|||The state of the main body can be acquired by the status acquisition command.||The state of the main body can be acquired by the status acquisition command.|The state of the main body can be acquired by the status acquisition command.| |Socket Communication|||Status acquisition available with PNS Command and PHN Command||Status acquisition available with PNS Command and PHN Command|| |SNMP Command|||||Status acquisition available with SNMP "get" Command|| |Version||||||v1 / v2c / v3| |HTTP Communication|||The state of the main body can be acquired in XML/JSON data format.|||| |||||||| ||||Acquisition data|||| |Command|||Signal Tower||Buzzer|| |RSH Command|||✓||✓|| |SSH Command|||✓||✓|| |Socket||PNS<br>PHN|✓<br>✓*1||✓<br>✓*2|| |SNMP Command|||✓||✓|| |XML/JSON format file|||✓||✓|| - *1 Signal Tower "Red", "Amber" and "Green", and Flashing pattern 1 - *2 Buzzer pattern 1 and Buzzer pattern 2 4.4 Main Unit Setting Function The internal clock in this product can communicate with an NTP server Time Correction Function es to automatically correct the time. Network setting in this product can communicate with an DHCP server Automatic Network Setting to automatically set. EE Buzzer Volume Setting Master Volume of Buzzer can be set Flash Control Setting The brightness of the LED unit can be reduced.*1 Standard Action Setting The color of Signal Tower that lights up after the clear operation is executed can be set. Self test of Signal Tower and buzzer is possible Self-test Function with test button of the main body and RSH/SSH command. Config Setting Various settings of the main body can be read and written as setting file. —— — Event Log Event logs can be downloaded via web browser and USB flash drive. USB flash drive can be used to read and written configuration files, USB Flash Drive Function — — update firmware, and download Event logs. Main Unit Setting Various settings of the main body can be done with a web browser. Supported browsers Google Chrome *2 Microsoft Edge *3 Languages supported Japanese, English, Traditional Chinese, Sinplified Chinese, Korean, Thai ——— on the setting screen German, French, Italian, Spanish, Mexican *1 Light reduction is not possible when using LR4/6-E-MZ or WDT-4/6LR-Z2. *2 Google Chrome is a trademark or registered trademark of Google LLC. *3 Microsoft Edge is registered trademark of Microsoft Corporation in the United States and other countries. ee |||Drawing No.<br>Rev.<br>Page| |---|---|---| |||NHB6-3-W18<br>E<br>7 / 10| |4.5. Cloud Function||| |Supported Cloud Platform||Microsoft Azure *1<br>Amazon Web Services (AWS) *2<br>CO<br>CO| |Azure<br>AWS|Azure IoT Central/DPS, Azure IoT Hub<br>(IoT Plug and Play)<br>Cloud-to-device Message<br>AWS IoT Core<br>Device Shadow, MQTT client<br>Connection<br>Settings<br>Device Twin, Direct Method, Device-to-cloud Message,<br>Built-in features<br>Connection Settings<br>Built-in features<br>es<br>a|| |Main Unit Control<br>a||Signal Tower, Buzzer| |Signal Tower, Buzzer<br>Main Unit Status Transmission<br>Built-in features, "Clear" button<br>Main Unit Status Acquisition<br>ee<br>es<br>ee||| - *1 Microsoft Azure is registered trademark of Microsoft Corporation in the United States and other countries. - *2 Amazon Web Services, the "Powered by AWS"logo, and any other AWS trademarks used in such materials are trademarks of Amazon.com, Inc. or its affiliates in the United States and other countries. **==> picture [186 x 32] intentionally omitted <==** **----- Start of picture text -----**<br> Drawing No. Rev. Page<br>NHB6-3-W18 E<br>8 / 10<br>**----- End of picture text -----**<br> **==> picture [456 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> NHB6 (Unit: mm)<br>**----- End of picture text -----**<br> **==> picture [393 x 90] intentionally omitted <==** **----- Start of picture text -----**<br> No. Parts name Material Color Number of LED L<br>1 Head Cover PC Off-white 0 tiers 150<br>2 LED Unit PC Clear 1 tier 190<br>3 Main Body ABS Off-white/Medium Gray 2 tiers 230<br>3 tiers 270<br>4 tiers 310<br>5 tiers 350<br>**----- End of picture text -----**<br> Drawing No. Rev. Page NHB6-3-W18 E 9 / 10 **==> picture [456 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> NHB4 (Unit: mm)<br>**----- End of picture text -----**<br> **==> picture [393 x 90] intentionally omitted <==** **----- Start of picture text -----**<br> No. Parts name Material Color Number of LED L<br>1 Head Cover PC Off-white 0 tiers 150<br>2 LED Unit PC Clear 1 tier 190<br>3 Main Body ABS Off-white/Medium Gray 2 tiers 230<br>3 tiers 270<br>4 tiers 310<br>5 tiers 350<br>**----- End of picture text -----**<br> Drawing No. NHB6-3-W18 |Rev.||Page| |---|---|---| |E|10 / 10|10 / 10| (Unit: mm)
Updated at June 9, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →