Image not available
Illustrative purposes only
NGB800S12K
AC/DC Open Frame Power Supply (PSU), ITE, Industrial & Medical, 1 Output, 690W, 468 W
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SL POWER / ADVANCED ENERGY
- Product type: AC / DC Open Frame Power Supplies
- SVHC: To Be Advised
- Product Range: NGB800 Series
- No. of Outputs: 1 Output
- Input Voltage VAC: 80V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 39A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 12V
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE, Industrial & Medical
- Power Rating (Forced Cooling): 690W
- Power Rating (Convection Cooling): 468W
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 332.82 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **SL POWER NGB800 SERIES** 800 Watts Single Output Medical & Industrial Grade Advanced Energy’s SL Power NGB800 series of open-frame AC-DC power supplies features ITE and medical safety approvals. The series offers a choice of four single output models, with voltages of 12 V, 15 V, 24 V, or 48 V. Each model also provides an isolated 12 V fan output, and 5 V standby output. NGB800 series power supplies provide 800 Watts of output power, and have a typical full load power conversion ## **AT A GLANCE** ## **Total Power** ## **800 Watts** ## **Input Voltage** **80 to 264 VAC** ## **# of Outputs** **Single** ## **SPECIAL FEATURES** - Up to 800 Watts with Air Flow - Up to 550 Watts Convection Cooled - 5” x 8” x 1.6” Size - Universal Input 80 to 264 VAC ## **SAFETY** - UL/CSA/IEC/EN 60601-1 Am1, BF Rated - UL/CSA/IEC/EN 62368-1 Am1 - CE Compliance - Meets Class B Emissions Levels - 7+ Years Electrolytic Capacitor Life - Meets 4th Edition / Heavy Industrial EMC - Meets Class B Emissions Levels ## **TYPICAL APPLICATIONS** - ITE - Medical - Less than 100 uA Leakage Current - -20ºC to 70ºC Operating Temperature Range - ROHS Compliant - REACH Compliant - 3 Years Warranty ©2023 Advanced Energy Industries, Inc. **NGB800** ## **ELECTRICAL SPECIFICATIONS** **==> picture [478 x 495] intentionally omitted <==** **----- Start of picture text -----**<br> Input<br>Input Ra nge 80 to 264 VAC, 47 to 63 Hz, 1Ø<br>Input Current 8.0 A max at 115 VAC, 4.0 A max at 230 VAC<br>Inrush Current 40 A max., cold start @ 264 VAC input<br>Input Fuses 12 A, 250 VAC fuse provided in both line & neutral<br>Leakage Current<br>Earth <500 μA @ 264 VAC, 60 Hz, NC<br>Patient (Output to Earth) <100/500 μA @ 264 VAC, 60 Hz, NC/SFC<br>Efficiency >90% typical<br>No Load Input Power <0.5 W<br>Isolation Voltage Input/Ground: 1500 VAC (1 MOPP)<br>Input/Output: 4500 VAC (2 MOPP)<br>Output/Ground: 1500 VAC (1 MOPP)<br>Output<br>Maximum Power See "Ordering information" section<br>Ripple and Noise 1% of Vout on all other models<br>Load Regulation 2%<br>Line Regulation 1%<br>Total Regulation 5%<br>Minimum Load Not required<br>Capacitive Load 1000 μF<br>Adjustment Range 5%<br>Initial Set Point Tolerance ±1 %<br>Overshoot <5% overshoot at turn-on, <1% overshoot at turn-off, under all conditions<br>PSU have monotonic wave forms on the main output at start up, shut down and fault (OVP, OCP, OTP, OPP,<br>Monotonic Waveform<br>SCP) triggered shutdown.<br>For any 50% load step over the range of 25% to 100% of rated load, ∆ i/ ∆ t<0.2 A/μs. Max. voltage deviation is<br>Transient Response<br>±3.5% of final value.<br>Reliability<br>MTBF >500K hrs, using Telcordia SR-332, Issue 3 at 110 V & 220 V, for both 25OC and 50OC<br>Warranty 3 years<br>All specified electrolytic capacitors will exceed 7 year life based on operating at 25°C ambient temp.,<br>Electrolytic Capacitor Lifetime<br>24 hrs/day, 365 days/year, 6 power up cycles/day.<br>Protection<br>Overvoltage Protection 105% to 140% of nominal output voltage. Latch mode.<br>Short circuit Protection Short across the output terminals will not cause damage to the unit. Hiccup mode.<br>Thermal Protection Will shutdown upon an over temperature condition. Auto-recovery mode.<br>Overload Protection 130% to 200% of rated output current value. Hiccup mode.<br>**----- End of picture text -----**<br> **2 advancedenergy.com** **NGB800** ## **EMI/EMC COMPLIANCE** **==> picture [479 x 260] intentionally omitted <==** **----- Start of picture text -----**<br> EN55011/15/32: Class B, CISPR11/15/32: Class B, FCC Part 15.107, Class B, Measured at 10%, 50%, and<br>Conducted Emissions<br>100% load steps; 6db margin typ, at 120 VAC and 230 VAC<br>EN55011/15/32: Class B, CISPR11/15/32: Class B, FCC Part 15.107, Class B, Measured at 10%, 50%, and<br>Radiated Emissions<br>100% load steps; 3db margin typ, at 120 VAC and 230 VAC<br>Harmonic Current Emissions EN61000-3-2, Class A at 230 VAC, 100% load<br>Voltage Fluctuations & Flicker IEC61000-3-3<br>Electro Static Discharge Immunity EN55024/IEC61000-4-2, Level 4: ±8kV contact, ±15kV air, Criteria A, IEC60601-1-2, 4th Edition, Table 4<br>Radiated RF EM Fields Susceptibility EN55022/EN61000-4-3, 10 V/m, 80 MHz to 2.7 GHz, 80% AM at 1 kHz IEC60601-1-2, 4th Edition, Table 4<br>Electrical Fast Transients / Bursts EN55024/IEC61000-4-4, Level 4, ±4 kV, 100 Khz rep rate, 40 A, Criteria A, IEC60601-1-2, 4th Edition, Table 5<br>Surges Line to Line (DM) and Line to EN55024/IEC61000-4-5, Level 4, ±2kV DM, ±4kV CM, Criteria A Surpasses IEC60601-1-2, 4th Edition<br>Ground (CM) requirements<br>Conducted Disturbances Induced by EN55022/IEC61000-4-6, 3 V/m – Level 4, 0.15 to 80 MHz; and 12V/m in ISM and amateur radio bands<br>RF Fields between 0.15 MHz and 80 MHz, 80% AM at 1 KHz IEC60601-1-2, 4th Edition, Table 5<br>Rated Power Frequency Magnetic<br>EN55024/IEC1000-4-8, Level 4: 30 A/m, 50Hz/60Hz IEC60601-1-2, 4th Edition, Table 4<br>Fields Test<br>EN55024/IEC/EN61000-4-11:<br>--100% dip for 10 ms, at 0°, 45°, 90°, 135°, 180°, 225°, 270° and 315°<br>--100% dip for 20ms, 0 deg., Criteria B at full load, criteria A @ 50% load<br>Voltage Dips2 --100% dip for 5000 ms (250/300 cycles), criteria B<br>--60% dip for 100 ms, criteria B<br>--30% dip for 500 ms, criteria A<br>IEC60601-1-2, 4th Edition, Table 5<br>**----- End of picture text -----**<br> Notes: 1. Performance criteria are based on EN55024. According to the standards, performance criteria are decoded as following: - A. Normal performance during and after the test - B. Temporary degradation, self-recoverable - C. Temporary degradation, operator intervention required to recover the operation - D. Permanent damage ## **SYSTEM TIMING SPECIFICATIONS** **==> picture [479 x 96] intentionally omitted <==** **----- Start of picture text -----**<br> Model Number Min Typ Max Unit<br>Turn-On Time – Main outputs 500 - 1000 ms<br>Turn-On Time – 5Vsb output - - 100 ms<br>Rise Time, 10% Vmain to Vmain in regulation - - 100 ms<br>Hold Up Time - All outputs stay within regulation after loss of AC @ 80% load 20 - - ms<br>Hold Up Time - Vsb stays within regulation after loss of AC 100 - - ms<br>Turn-On Time at -20°C - 300 - ms<br>**----- End of picture text -----**<br> **advancedenergy.com 3** **NGB800** ## **ORDERING INFORMATION** **==> picture [480 x 94] intentionally omitted <==** **----- Start of picture text -----**<br> With Air1 Convection Conduction Terminations<br>Model Output Standby<br>Number Voltage Output Output Output Output Output Output Output Input Output<br>Current Power Current Power Current Power<br>NGB800S12K 12 V 57.5 A 690 W 39.0 A 468 W 44.8 A 538 W<br>Screw<br>NGB800S15K 15 V 46.0 A 690 W 26.7 A 400 W 35.9 A 538 W Screw<br>5 V @ 2A Terminals<br>NGB800S24K 24 V 33.3 A 800 W 22.9 A 550 W 26.3 A 632 W (Class I) Terminals<br>NGB800S48K 48 V 16.7 A 800 W 11.4 A 550 W 13.2 A 632 W<br>**----- End of picture text -----**<br> Note: 1. Airflow: ≥300LFM. ## **ENVIRONMENTAL SPECIFICATIONS** **==> picture [479 x 193] intentionally omitted <==** **----- Start of picture text -----**<br> Operating Temperature -20°C to +70°C<br>Temperature Derating Derate output power linearly above 50°C to 50% rated output at 70°C<br>Storage Temperature -40°C to +85°C<br>Random Vibration:<br>Operating: 0.003 g/Hz, 1.5 grams overall, 3 axes, 10 min/axis, 5 to 500 Hz.<br>Non-operating: Random waveform, 3 mins/axis, 3 axes and sine waveform, Vib. frequency / acceleration:10 Hz<br>Vibration<br>to 500 Hz / 1 g, sweep rate of 1 octave/minutes, vibration time of 10 sweeps/axes, 3 axes.<br>Transportation vibration: Random vib. per MIL-STD-810E, Method 514.4, Cat. 1, Figure 514.4-1, 1hr in each of<br>three axes.<br>Operating: Half-sine, 20 gpk, 10 ms, 3 axes, 6 shocks total.<br>Shock (IEC 60068-2-27) Non-operating: Half-sine waveform, impact acceleration of 50 g, pulse duration of 6 ms.<br>Number of shocks: 3 for each of the three axis<br>Cooling Airflow: ≥300LFM, convection, and conduction<br>Audible Noise <20 dbA<br>Altitude Operating: -500 to 5,000 m. Non-operating: -500 to 12,192 m<br>Relative Humidity 5% to 95%, non-condensing<br>**----- End of picture text -----**<br> ## **SAFETY** |UL|UL62368-1, UL60601-1-1, 3rd Edition + Am1. BF rated.| |---|---| |CSA|CAN/CSA-C22.2 No. 62368-1, 60601-1, Am1. BF rated.| |Demko|EN62368-1 EN60601-1-1, 3rd Edition. BF rated.| |CB Report|Design to meet 5000 m and 50°C, 93% RH with 120 h (Tropical standard) according to GB4943 1-2011,<br>IEC62368-1, IEC60601-1-1 Am1, BF rated.| |CE|CE Mark| **4 advancedenergy.com** **NGB800** ## **UNIT PACKAGING REQUIREMENTS** **==> picture [479 x 85] intentionally omitted <==** **----- Start of picture text -----**<br> Inserted Instructions Instruction sheet to be provided with all units packaged in individual unit box if used.<br>Individual Unit Packing Units can be packed in egg crate type cartons for production quantities. Individual product shipments include an<br>individual unit box.<br>16 units per master carton. Only anti-static packing material may be used inside the box. Exterior box sealing tape<br>Master Carton Shipping Box<br>is anti-static type.<br>Individual Carton Packing Box Individual carton is labelled with ROHS sticker and individual label showing unit serial number, bar code,<br>(When Used) manufacturing date, bar code, and manufacturing part number, bar code, country of origin.<br>**----- End of picture text -----**<br> ## **PIN ASSIGNMENTS** **==> picture [479 x 273] intentionally omitted <==** **----- Start of picture text -----**<br> Type Connector Pin # Assignment Mating Connector<br>1 Ground<br>INPUT J100 2 AC Line Molex: 19141-0052/0053<br>3 AC Neutral<br>J103 1 +Vout Molex: 19141-0058/0063/0065/<br>J104 2 -Vout 0059/0064 /0066<br>1 RTN<br>2 NA<br>3 S+<br>4 RTN<br>5 NA<br>6 DC OK Housing:<br>OUTPUT<br>7 NA LANDWIN: 2050S1400<br>J400<br>8 ON_OFF Pins:<br>9 NA LANDWIN: 2053T021N<br>10 Fan Output<br>11 RTN<br>12 NA<br>13 5VSB<br>14 5VSB<br>**----- End of picture text -----**<br> **advancedenergy.com 5** **NGB800** ## **MECHANICAL DRAWING** Notes: 1. All dimensions in mm (inches). 2. Dimensions: W: 5” Wx L: 8” x H: 1.6”. 3. Unit weight: 1200 g. **6 advancedenergy.com** **==> picture [596 x 270] intentionally omitted <==** ## **ABOUT ADVANCED ENERGY** Advanced Energy (AE) has devoted more than three decades to perfecting power for its global customers. AE designs and manufactures highly engineered, precision power conversion, measurement and control solutions for mission-critical applications and processes. Our products enable customer innovation in complex applications for a wide range of industries including semiconductor equipment, industrial, manufacturing, telecommunications, data center computing, and medical. With deep applications know-how and responsive service and support across the globe, we build collaborative partnerships to meet rapid technological developments, propel growth for our customers, and innovate the future of power. ## **TRUST** For international contact information, visit advancedenergy.com. powersales@aei.com (Sales Support) productsupport.ep@aei.com (Technical Support) +1 888 412 7832 Specifications are subject to change without notice. Not responsible for errors or omissions. ©2023 Advanced Energy Industries, Inc. All rights reserved. Advanced Energy®, and AE® are U.S. trademarks of Advanced Energy Industries, Inc. ENG-NGB800-09.11.23
Updated at April 22, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →