Image not available
Illustrative purposes only
NCB4-12GM40-N0-V1
SENSOR, INDUCTIVE, 4MM, 8.2V
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: PEPPERL+FUCHS PA
- Product type: Inductive Proximity Sensors
- Sensor Type:Inductive Proximity Sensor; Operating Temperature Max:100°C; Supply Voltage Min:-; Supply Voltage Max:8.2V; Sensor Output Type:2-Wire, NAMUR, NC; Sensor Case 29M5310
- Sensor Type: Inductive Proximity Sensor
- Sensing Range Max: 4mm
- Sensor Output Type: NAMUR
- Sensing Distance Nom: 4mm
- Thread Size - Metric: M12
- Sensor Case / Package: Cylindrical M12 Thread
- Supply Voltage DC Max: -
- Supply Voltage DC Min: -
| Delivery and price | |
|---|---|
| Units per pack | 25 |
| Price | 92.63 € |
| Current stock | 10+ |
| Lead time | 30 days |
**NCB4-12GM40-N0-V1** **Inductive sensor** ## **Technical Data** C€ 0102 **Model Number** eae) **NCB4-12GM40-N0-V1** **Features** ~~a~~ **• 4 mm flush • Usable up to SIL 2 acc. to IEC 61508** **Accessories** eae) **BF 12** Mounting flange, 12 mm **V1-G-N-2M-PUR** Female cordset, M12, 2-pin, NAMUR, PUR cable **V1-W-N-2M-PUR** Female cordset, M12, 2-pin, NAMUR, PUR cable |**General specifications**||| |---|---|---| |Switching element function||NAMUR, NC| |Rated operating distance|sn|4 mm| |Installation||flush| |Output polarity||NAMUR| |Assured operating distance|sa|0 ... 3.24 mm| |Actual operating distance|sr|3.6 ... 4.4 mm typ.| |Reduction factor rAl||0.41| |Reduction factor rCu||0.39| |Reduction factor r304||0.78| |**Nominal ratings**||| |Nominal voltage|Uo|8.2 V (Riapprox. 1 kΩ)| |Switching frequency|f|0 ... 1500 Hz| |Hysteresis|H|1 ... 15 typ. 5 %| |Reverse polarity protection||reverse polarity protected| |Short-circuit protection||yes| |Suitable for 2:1 technology<br>Current consumption<br>Measuring plate not detected<br>Measuring plate detected||yes , Reverse polarity protection diode not required<br>≥2.2 mA<br>≤1 mA| |Switching state indicator||Multihole-LED, yellow| |**Functional safety related parameters**||| |MTTFd||3010 a| |Mission Time (TM)<br>Diagnostic Coverage (DC)<br>**Ambient conditions**||20 a<br>0 %| |Ambient temperature<br>Storage temperature||-25 ... 100 °C (-13 ... 212 °F)<br>-40 ... 100 °C (-40 ... 212 °F)| |**Mechanical specifications**<br>Connection type<br>Core cross-section<br>Housing material||Connector M12 x 1 , 4-pin<br>-<br>Stainless steel 1.4305 / AISI 303| |Sensing face<br>Degree of protection||PBT<br>IP67| |**General information**<br>Scope of delivery||2 self locking nuts in scope of delivery| |Use in the hazardous area||see instruction manuals| |Category||1G; 2G; 3G; 3D| |**Compliance with standards and directives**|**Compliance with standards and directives**|| |Standard conformity||| |NAMUR||EN 60947-5-6:2000<br>IEC 60947-5-6:1999| |Electromagnetic compatibility||NE 21:2007| |Standards||EN 60947-5-2:2007| |||IEC 60947-5-2:2007| |**Approvals and certificates**||| |FM approval||| |Control drawing||116-0165| |UL approval||cULus Listed, General Purpose| |CSA approval||cCSAus Listed, General Purpose| |CCC approval||CCC approval / marking not required for products rated≤36 V| ~~|~~ **Dimensions** M12x1 **==> picture [62 x 71] intentionally omitted <==** **----- Start of picture text -----**<br> ae<br>17<br>al<br>LED<br>M12x1 =n<br>4<br>40<br>55<br>6<br>**----- End of picture text -----**<br> ~~SS—_WT—_—_—_—11————~~ Pepperl+Fuchs GroupRefer to “General Notes Relating to PeUSA: +1 330 486 0001pperl+Fuchs Product Information”.Germany: +49 621 776 4411 Singapore: +65 6779 9091 ~~_~~ EJpEppERL ~~+~~ FUCHS www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@de.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com SENSING YOUR NEEDS **1** **NCB4-12GM40-N0-V1** **Inductive sensor** **Electrical Connection** **==> picture [86 x 40] intentionally omitted <==** **----- Start of picture text -----**<br> 1<br>L+<br>2<br>L-<br>**----- End of picture text -----**<br> ## **Pinout** **==> picture [50 x 54] intentionally omitted <==** **----- Start of picture text -----**<br> 1<br>2 4<br>3<br>**----- End of picture text -----**<br> Wire colors in accordance with EN 60947-5-6 1 BN (brown) 2 BU (blue) Refer to “General Notes Relating to Pepperl+Fuchs Product Information”. Pepperl+Fuchs Group USA: +1 330 486 0001 Germany: +49 621 776 4411 Singapore: +65 6779 9091 www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@de.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com 2 **NCB4-12GM40-N0-V1** **Inductive sensor** **Equipment protection level Ga** Instruction **Manual electrical apparatus for hazardous areas** Device category 1G for use in hazardous areas with gas, vapour and mist EC-Type Examination Certificate PTB 00 ATEX 2048 X CE marking 0102 ATEX marking ¬ II 1G Ex ia IIC T6 … T1 Ga The Ex-related marking can also be printed on the enclosed label. Directive conformity 94/9/EG Standards EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection "Intrinsic safety" Use is restricted to the following stated conditions Appropriate type NCB4-12GM...-N0... Effective internal inductivity Ci ≤ 120 nF ; a cable length of 10 m is considered. Effective internal inductance Li ≤ 50 µ H ; a cable length of 10 m is considered. General The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The EC-Type Examination Certificate has to be observed. The special conditions must be adhered to! Directive 94/9/EG and hence also EC-Type Examination Certificates apply in general only to the use of electrical apparatus under atmospheric conditions. The use in ambient temperatures of > 60 °C was tested with regard to hot surfaces by the mentioned certification authority. If the equipment is not used under atmospheric conditions, a reduction of the permissible minimum ignition energies may have to be taken into consideration. Ambient temperature Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. **Note:** Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 11271 has already been applied to the temperature table for category 1. Installation, commissioning Laws and/or regulations and standards governing the use or intended usage goal must be observed. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. The associated apparatus must satisfy the requirements of category ia. Due to the possible danger of ignition, which can arise due to faults and/or transient currents in the equipotential bonding system, galvanic isolation of the power supply and signal circuit is preferable. Associated apparatus without electrical isolation must only be used if the appropriate requirements of IEC 60079-14 are met. If the Exrelated marking is printed only on the supplied label, then this must be attached in the immediate vicinity of the sensor. The sticking surface for the label must be clean and free from grease. The attached label must be legible and indelible, including in the event of possible chemical corrosion. Maintenance No changes can be made to apparatus, which are operated in hazardous areas. Repairs to these apparatus are not possible. **Special conditions** The connecting parts of the sensor must be set up in such a way that degree of protection IP20, in accordance with lEC 60529, is achieved as a minimum. Protection from mechanical danger When using the device in a temperature range of -60 °C to -20 °C, protect the sensor against the effects of impact by installing an additional enclosure. The information regarding the minimum ambient temperature for the sensor as provided in the datasheet must also be observed. Electrostatic charge Electrostatic charges must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. Refer to “General Notes Relating to Pepperl+Fuchs Product Information”. Pepperl+Fuchs Group USA: +1 330 486 0001 Germany: +49 621 776 4411 Singapore: +65 6779 9091 www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@de.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com **3** **NCB4-12GM40-N0-V1** **Inductive sensor** |**Equipment protection level Gb**||||| |---|---|---|---|---| |Instruction||**Manual electrical apparatus for hazardous areas**||| |**Device category 2G**||for use in hazardous areas with gas, vapour and mist||| |EC-Type Examination Certificate||PTB 00 ATEX 2048 X||| |CE marking||||0102| |ATEX marking||¬II 1G Ex ia IIC T6…T1 Ga||| |||The||Ex-significant identification is on the enclosed adhesive label| |Directive conformity||94/9/EG||| |Standards||EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection "Intrinsic safety"||| |||Use||is restricted to the following stated conditions| |Appropriate type||NCB4-12GM...-N0...||| |Effective internal inductivity|Ci|≤|120 nF ; a cable length of 10 m is considered.|| |Effective internal inductance|Li|≤|50µH ; a cable length of 10 m is considered.|| |General||The||apparatus has to be operated according to the appropriate data in the data sheet| |||and||in this instruction manual. The EC-Type Examination Certificate has to be| |||observed. The special conditions must be adhered to!||| |||Directive 94/9/EG and hence also EC-Type Examination Certificates apply in general||| |||only||to the use of electrical apparatus under atmospheric conditions.| |||The||use in ambient temperatures of > 60 °C was tested with regard to hot surfaces| |||by the mentioned certification authority.||| |||If the equipment is not used under atmospheric conditions, a reduction of the permis-||| |||sible minimum ignition energies may have to be taken into consideration.||| |Maximum permissible ambient temperature Tamb||Details of the correlation between the type of circuit connected, the maximum per-||| |||missible ambient temperature, the temperature class, and the effective internal reac-||| |||tance values can be found on the EC-type examination certificate.||| |Installation, commissioning||Laws and/or regulations and standards governing the use or intended usage goal||| |||must be observed. The intrinsic safety is only assured in connection with an appro-||| |||priate related apparatus and according to the proof of intrinsic safety.||| |||If|the Ex-related marking is printed only on the supplied label, then this must be|| |||attached in the immediate vicinity of the sensor. The sticking surface for the label||| |||must be clean and free from grease. The attached label must be legible and indeli-||| |||ble, including in the event of possible chemical corrosion.||| |Maintenance||No changes can be made to apparatus, which are operated in hazardous areas.||| |||Repairs to these apparatus are not possible.||| |**Special conditions**||The||connecting parts of the sensor must be set up in such a way that degree of pro-| |||tection IP20, in accordance with lEC 60529, is achieved as a minimum.||| |Protection from mechanical danger||When using the device in a temperature range of -60 °C to -20 °C, protect the sensor||| |||against the effects of impact by installing an additional enclosure. The information||| |||regarding the minimum ambient temperature for the sensor as provided in the||| |||datasheet must also be observed.||| |Electrostatic charge||Electrostatic charges must be avoided on the mechanical housing components.||| |||Dangerous electrostatic charges on the mechanical housing components can be||| |||avoided by incorporating these in the equipotential bonding.||| Refer to “General Notes Relating to Pepperl+Fuchs Product Information”. Pepperl+Fuchs Group USA: +1 330 486 0001 Germany: +49 621 776 4411 Singapore: +65 6779 9091 www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@de.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com 4 **NCB4-12GM40-N0-V1** **Inductive sensor** ## **Equipment protection level Gc (nL)** Note **Instruction** **Device category 3G (nL)** CE marking ATEX marking Directive conformity Standard conformity Effective internal capacitance Ci Effective internal inductance Li General This instruction is only valid for products according to EN 60079-15:2005, valid until 01-May-2013 **Manual electrical apparatus for hazardous areas** for use in hazardous areas with gas, vapour and mist 0102 ¬ II 3G Ex nL IIC T6 X The Ex-significant identification is on the enclosed adhesive label 94/9/EG EN 60079-15:2005 Ignition protection category "n" Use is restricted to the following stated conditions ≤ 120 nF ; a cable length of 10 m is considered. ≤ 50 µ H ; A cable length of 10 m is considered. The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be observed! Installation, commissioning Maintenance Laws and/or regulations and standards governing the use or intended usage goal must be observed. The sensor must only be operated with an energy-limited circuit, which satisfies the requirements of IEC 60079-15. The explosion group complies with the connected, supplying, power limiting circuit. The adhesive label provided must be affixed in the immediate vicinity of the sensor! The surface to which the label is applied must be clean, flat and free from grease! The affixed adhesive label must be readable and durable, taking account of the possibility of chemical corrosion! No changes can be made to apparatus, which are operated in hazardous areas. Repairs to these apparatus are not possible. ## **Special conditions** for Pi=34 mW, Ii=25 mA, T6 for Pi=34 mW, Ii=25 mA, T5 for Pi=34 mW, Ii=25 mA, T4-T1 for Pi=64 mW, Ii=25 mA, T6 for Pi=64 mW, Ii=25 mA, T5 for Pi=64 mW, Ii=25 mA, T4-T1 for Pi=169 mW, Ii=52 mA, T6 for Pi=169 mW, Ii=52 mA, T5 for Pi=169 mW, Ii=52 mA, T4-T1 for Pi=242 mW, Ii=76 mA, T6 for Pi=242 mW, Ii=76 mA, T5 for Pi=242 mW, Ii=76 mA, T4-T1 Protection from mechanical danger Protection from UV light Electrostatic charge Connection parts 55 °C (131 °F) 55 °C (131 °F) 55 °C (131 °F) 55 °C (131 °F) 55 °C (131 °F) 55 °C (131 °F) 41 °C (105.8 °F) 41 °C (105.8 °F) 41 °C (105.8 °F) 29 °C (84.2 °F) 29 °C (84.2 °F) 29 °C (84.2 °F) The sensor must not be exposed to **ANY FORM** of mechanical danger. When used in the temperature range below -20 °C the sensor should be protected from knocks by the provision of an additional housing. The sensor and the connection cable must be protected from damaging UV-radiation. This can be achieved when the sensor is used in internal areas. Electrostatic charges must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. The connection parts are to be installed, such that a minimum protection class of IP20 is achieved, in accordance with IEC 60529. Refer to “General Notes Relating to Pepperl+Fuchs Product Information”. Pepperl+Fuchs Group USA: +1 330 486 0001 Germany: +49 621 776 4411 Singapore: +65 6779 9091 www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@de.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com **5** **NCB4-12GM40-N0-V1** **Inductive sensor** ## **Equipment protection level Gc (ic)** **Manual electrical apparatus for hazardous areas** Instruction **Manual electrical apparatus for hazardous areas Device category 3G (ic)** for use in hazardous areas with gas, vapour and mist Certificate of Compliance PF 13 CERT 2895 X CE marking ATEX marking ¬ II 3G Ex ic IIC T6 … T1 Gc The Ex-significant identification is on the enclosed adhesive label Directive conformity 94/9/EG Standards EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection category "ic" Use is restricted to the following stated conditions Effective internal inductivity Ci ≤ 120 nF ; a cable length of 10 m is considered. Effective internal inductance Li ≤ 50 µ H ; A cable length of 10 m is considered. General The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be observed! Installation, commissioning Laws and/or regulations and standards governing the use or intended usage goal must be observed. The sensor must only be operated with energy-limited circuits, which satisfy the requirements of IEC 60079-11. The explosion group complies with the connected, supplying, power limiting circuit. If the Ex-relevant identification is printed exclusively on the adhesive label provided, this label must be affixed in the immediate vicinity of the sensor! The background surface to which the adhesivelabel is to be applied must be clean and free from grease! The applied label must be durable and remain legible, with due consideration of the possibility of chemical corrosion! Maintenance No changes can be made to apparatus, which are operated in hazardous areas. Repairs to these apparatus are not possible. **Special conditions** for Pi=34 mW, Ii=25 mA, T6 55 °C (131 °F) for Pi=34 mW, Ii=25 mA, T5 55 °C (131 °F) for Pi=34 mW, Ii=25 mA, T4-T1 55 °C (131 °F) for Pi=64 mW, Ii=25 mA, T6 55 °C (131 °F) for Pi=64 mW, Ii=25 mA, T5 55 °C (131 °F) for Pi=64 mW, Ii=25 mA, T4-T1 55 °C (131 °F) for Pi=169 mW, Ii=52 mA, T6 41 °C (105.8 °F) for Pi=169 mW, Ii=52 mA, T5 41 °C (105.8 °F) for Pi=169 mW, Ii=52 mA, T4-T1 41 °C (105.8 °F) for Pi=242 mW, Ii=76 mA, T6 29 °C (84.2 °F) for Pi=242 mW, Ii=76 mA, T5 29 °C (84.2 °F) for Pi=242 mW, Ii=76 mA, T4-T1 29 °C (84.2 °F) Protection from mechanical danger The sensor must not be mechanically damaged. When used in the temperature range below -20 °C the sensor should be protected from knocks by the provision of an additional housing. Electrostatic charge Electrostatic charges must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. Connection parts The connection parts are to be installed, such that a minimum protection class of IP20 is achieved, in accordance with IEC 60529. The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be observed! Refer to “General Notes Relating to Pepperl+Fuchs Product Information”. Pepperl+Fuchs Group USA: +1 330 486 0001 Germany: +49 621 776 4411 Singapore: +65 6779 9091 www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@de.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com 6 **NCB4-12GM40-N0-V1** **Inductive sensor** **Equipment protection level Da** Instruction **Manual electrical apparatus for hazardous areas Device category 1D** for use in hazardous areas with combustible dust EC-Type Examination Certificate PTB 00 ATEX 2048 X CE marking 0102 ATEX marking ¬ II 1D Ex ia IIIC T135°C Da The Ex-related marking can also be printed on the enclosed label. Directive conformity 94/9/EG Standards EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection "Intrinsic safety" Use is restricted to the following stated conditions Appropriate type NCB4-12GM...-N0... Effective internal inductivity Ci ≤ 120 nF A cable length of 10 m is considered. Effective internal inductance Li ≤ 50 µ H ; a cable length of 10 m is considered. General The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The EC-Type Examination Certificate has to be observed. Directive 94/9/EG and hence also EC-Type Examination Certificates apply in general only to the use of electrical apparatus under atmospheric conditions. The use in ambient temperatures of > 60 °C was tested with regard to hot surfaces by the mentioned certification authority. If the equipment is not used under atmospheric conditions, a reduction of the permissible minimum ignition energies may have to be taken into consideration. Maximum permissible ambient temperature Tamb Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the surface temperature, and the effective internal reactance values can be found on the EC-type-examination certificate. **The maximum permissible ambient temperature of the data sheet must be noted, in addition, the lower of the two values must be maintained.** Installation, commissioning Laws and/or regulations and standards governing the use or intended usage goal must be observed. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. If the Ex-related marking is printed only on the supplied label, then this must be attached in the immediate vicinity of the sensor. The sticking surface for the label must be clean and free from grease. The attached label must be legible and indelible, including in the event of possible chemical corrosion. Maintenance No changes can be made to apparatus, which are operated in hazardous areas. Repairs to these apparatus are not possible. **Special conditions** The connecting parts of the sensor must be set up in such a way that degree of protection IP20, in accordance with lEC 60529, is achieved as a minimum. Protection from mechanical danger When using the device in a temperature range of -60 °C to -20 °C, protect the sensor against the effects of impact by installing an additional enclosure. The information regarding the minimum ambient temperature for the sensor as provided in the datasheet must also be observed. Electrostatic charge Electrostatic charges must be avoided on the mechanical housing components. Electrostatic charges must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. Do not attach the nameplate provided in areas where electrostatic charge can build up. Refer to “General Notes Relating to Pepperl+Fuchs Product Information”. Pepperl+Fuchs Group USA: +1 330 486 0001 Germany: +49 621 776 4411 Singapore: +65 6779 9091 www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@de.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com **7** **NCB4-12GM40-N0-V1** **Inductive sensor** |**Equipment protection level Dc**||||| |---|---|---|---|---| |Note||**This instruction is only valid for products according to EN 50281-1-1, valid until 30-September-2008**||| |||Note the ex-marking on the sensor or on the enclosed adhesive label||| |**Instruction**||**Manual electrical apparatus for hazardous areas**||| |**Device category 3D**||for|use in hazardous areas with non-conducting combustible dust|| |CE marking||||0102| |ATEX marking||¬II 3D IP67 T 111 °C (231.8 °F) X||| |||The||Ex-significant identification is on the enclosed adhesive label| |Directive conformity||94/9/EG||| |Standards||EN 50281-1-1||| |||Protection via housing||| |||Use||is restricted to the following stated conditions| |General||The||apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual.| |||The||data stated in the data sheet are restricted by this operating instruction! The special conditions must be adhered to!| |Installation, commissioning||Laws and/or regulations and standards governing the use or intended usage goal must be observed.||| |||The||adhesive label provided must be affixed in the immediate vicinity of the sensor! The surface to which the label is applied| |||must be clean, flat and free from grease! The affixed adhesive label must be readable and durable, taking account of the possi-||| |||bility of chemical corrosion!||| |Maintenance||No|changes can be made to apparatus, which are operated in hazardous areas.|| |||Repairs to these apparatus are not possible.||| |**Special conditions**||||| |Maximum operating voltage|UBmax|The||maximum permissible operating voltage UBmax must be restricted to the values given in the following list. Tolerances are| |||not permitted.||| |Minimum series resistance|RV|A minimum series resistance RV is to be provided between the power supply voltage and the proximity switch in accordance||| |||with||the following list. This can also be assured by using a switch amplifier.| |Maximum heating (Temperature|rise)|Values can be obtained from the following list, depending on the max. operating voltage Ub max and the minimum series resis-||| |||tance Rv.||| |at UBmax=9 V, RV=562Ω||11|K|| |using an amplifier in accordance with||11|K|| |EN 60947-5-6||||| |Protection from mechanical danger||The||sensor must not be mechanically damaged.| |Electrostatic charge||Electrostatic charges must be avoided on the mechanical housing components. Dangerous electrostatic charges on the||| |||mechanical housing components can be avoided by incorporating these in the equipotential bonding.||| |Plug connector||The||plug connector must not be disconnected under voltage. The proximity switch is marked as follows: "DO NOT DISCON-| |||NECT UNDER VOLTAGE!" When the plug connector is disconnected the ingress of dirt into the inner areas (i.e. the areas,||| |||which are not accessible in the plugged-in condition) must be prevented.||| |||The||plug connection can only be separated using a tool. This is achieved by using the locking protection V1-Clip (Mounting| |||accessory from Pepperl + Fuchs).||| Refer to “General Notes Relating to Pepperl+Fuchs Product Information”. Pepperl+Fuchs Group USA: +1 330 486 0001 Germany: +49 621 776 4411 Singapore: +65 6779 9091 www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@de.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com 8 **NCB4-12GM40-N0-V1** **Inductive sensor** |**Equipment protection level Dc (tD)**||| |---|---|---| |Note|**This instruction is only valid for products according to EN 61241-0:2006 and EN 61241-1:2004**|| ||Note the ex-marking on the sensor or on the enclosed adhesive label|| |**Instruction**|**Manual electrical apparatus for hazardous areas**|| |**Device category 3D**|for use in hazardous areas with non-conducting combustible dust|| |CE marking||0102| |ATEX marking|¬II 3D Ex tD A22 IP67 T80°C X|| ||The|Ex-relevant identification may also be printed on the accompanying adhesive label.| |Directive conformity|94/9/EG|| |Standards|EN 61241-0:2006, EN 61241-1:2004|| ||Protection via housing "tD"|| ||Use|is restricted to the following stated conditions| |General|The|apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual.| ||The|maximum surface temperature has been determined in accordance with method A without a dust layer on the equipment.| ||The|data stated in the data sheet are restricted by this operating instruction!| ||The|special conditions must be adhered to!| |Installation, commissioning|The|statutory requirements, directives and standards applicable to the intended use and application must be observed.| ||The|adhesive label provided must be affixed in the immediate vicinity of the sensor! The surface to which the label is applied| ||must be clean, flat and free from grease! The affixed adhesive label must be readable and durable, taking account of the possi-|| ||bility of chemical corrosion!|| |Maintenance|No changes can be made to apparatus, which are operated in hazardous areas.|| ||Repairs to these apparatus are not possible.|| |**Special conditions**||| |Minimum series resistance RV|A minimum series resistance RV is to be provided between the power supply voltage and the proximity switch in accordance|| ||with|the following list. This can also be assured by using a switch amplifier.| |Maximum operating voltage UBmax|The|maximum permissible operating voltage UBmax must be restricted to the values given in the following list. Tolerances are| ||not permitted.|| |Maximum permissible ambient tempera-|Values can be obtained from the following list, depending on the max. operating voltage Ub max and the minimum series resis-|| |ture TUmax|tance Rv.|| |at UBmax=9 V, RV=562Ω|58 °C (136.4 °F)|| |using an amplifier in accordance with|58 °C (136.4 °F)|| |EN 60947-5-6||| |Protection from mechanical danger|The|sensor must not be exposed to**ANY FORM**of mechanical danger.| |Protection from UV light|The|sensor and the connection cable must be protected from damaging UV-radiation. This can be achieved when the sensor is| ||used in internal areas.|| |Electrostatic charge|Electrostatic charges must be avoided on the mechanical housing components. Dangerous electrostatic charges on the|| ||mechanical housing components can be avoided by incorporating these in the equipotential bonding.|| |Plug connector|The|plug connector must not be withdrawn under voltage. The proximity switch is identified as follows: "WARNING - DO NOT| ||SEPARATE WHEN ENERGIZED". With the plug connector disconnected, soiling of the internal area must be prevented.(i.e.|| ||the area that is inaccessible when the connector is inserted) The plug connection can only be separated using a tool.This is|| ||achieved by using the locking protection V1-Clip (Mounting accessory from Pepperl + Fuchs).|| Refer to “General Notes Relating to Pepperl+Fuchs Product Information”. Pepperl+Fuchs Group USA: +1 330 486 0001 Germany: +49 621 776 4411 Singapore: +65 6779 9091 www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@de.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com **9** **NCB4-12GM40-N0-V1** **Inductive sensor** **Equipment protection level Dc (tc)** Instruction **Manual electrical apparatus for hazardous areas Device category 3D** for use in hazardous areas with combustible dust Certificate of Compliance PF 15CERT3774 X CE marking ATEX marking ¬ II 3D Ex tc IIIC T80°C Dc The Ex-related marking can also be printed on the enclosed label. Directive conformity 94/9/EG Standards EN 60079-0:2012+A11:2013, EN 60079-31:2014 Protection by enclosure "tc" Some of the information in this instruction manual is more specific than the information provided in the datasheet. General The corresponding datasheets, declarations of conformity, EC-type examination certificates, certifications, and control drawings, where applicable (see datasheets), form an integral part of this document. These documents can be found at www.pepperlfuchs.com. The maximum surface temperature of the device was determined without a layer of dust on the apparatus. Some of the information in this instruction manual is more specific than the information provided in the datasheet. Installation, commissioning Laws and/or regulations and standards governing the use or intended usage goal must be observed. If the Ex-relevant identification is printed exclusively on the adhesive label provided, this label must be affixed in the immediate vicinity of the sensor! The background surface to which the adhesivelabel is to be applied must be clean and free from grease! The applied label must be durable and remain legible, with due consideration of the possibility of chemical corrosion! Maintenance No changes can be made to apparatus, which are operated in hazardous areas. Repairs to these apparatus are not possible. **Special conditions** Minimum series resistance RV A minimum series resistance RV is to be provided between the power supply voltage and the proximity switch in accordance with the following list. This can also be assured by using a switch amplifier. Maximum operating voltage UBmax The maximum permissible operating voltage UBmax must be restricted to the values given in the following list. Tolerances are not permitted. Maximum permissible ambient temperature TUmax Values can be obtained from the following list, depending on the max. operating voltage Ub max and the minimum series resistance Rv. at UBmax=9 V, RV=562 Ω 58 °C (136.4 °F) using an amplifier in accordance with EN 60947-5-6 58 °C (136.4 °F) Protection from mechanical danger The sensor must not be exposed to **ANY FORM** of mechanical danger. Protection from UV light The sensor and the connection cable must be protected from damaging UV-radiation. This can be achieved when the sensor is used in internal areas. Electrostatic charge Electrostatic charges must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. Do not attach the nameplate provided in areas where electrostatic charge can build up. Plug connector The plug connector must not be withdrawn under voltage. The proximity switch is identified as follows: "WARNING - DO NOT SEPARATE WHEN ENERGIZED". With the plug connector disconnected, soiling of the internal area must be prevented.(i.e. the area that is inaccessible when the connector is inserted) Refer to “General Notes Relating to Pepperl+Fuchs Product Information”. Pepperl+Fuchs Group USA: +1 330 486 0001 Germany: +49 621 776 4411 Singapore: +65 6779 9091 www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@de.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com 10
Updated at April 21, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 420,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →