Image not available
Illustrative purposes only
NBC-10-472
Power Line Filter, General Purpose, 250 V, 10 A, Single Phase, 2 Stage, Chassis Mount
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: COSEL
- Product type:
- SVHC: No SVHC (04-Feb-2026)
- No. of Phases: Single Phase
- No. of Stages: 2 Stage
- Product Range: NBC Series
- Current Rating: 10A
- Voltage Rating: 250V
- Filter Mounting: Chassis Mount
- Filter Applications: General Purpose
- Filter Input Terminals: Screw
- Filter Output Terminals: Screw
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 22.19 € |
| Current stock | 10+ |
| Lead time | 30 days |
**==> picture [508 x 224] intentionally omitted <==** **----- Start of picture text -----**<br> High-attenuation type of common mode noise from 150kHz to 1MHz (2-stage filter) Ordering information<br> NBC -10 -472 - O<br>NBC series<br>1 2 3 4<br>Ys _—<br>1 Model Name<br>R 2 Rated Current<br>3 Line to ground capacitor code:See table 1.1.<br>cli OS Ko |<br>table1.1 Line to ground capacitor code<br>Line to ground<br>Code Leakage Current capacitor<br>(Input 125/250V 60Hz)<br>(nominal value)<br>681 75.5 A/ 150 A max 680pF<br>@ a oo re ee 102 re 0.13mA/ 0.25mA max 1000pF<br>222 0.25mA/ 0.5 mA max 2200pF<br>332 0.38mA/ 0.75mA max 3300pF<br>472 0.5 mA/ 1.0 mA max 4700pF<br>* When the line to ground capacitor code is<br>different, the attenuation characteristic is<br>different.<br>4 Options<br>D :DIN rail installation type<br>DIN rail installation type is option The terminal cover is retracted inside the unit<br>**----- End of picture text -----**<br> - **The dimensions change when the option is set. Refer to External view.** ## **Features of NBC series** ## **High-attenuation type of common mode noise from 150kHz to 1MHz (2-stage filter)** - **Single Phase 250 VAC** - **Push down type terminal block** ## **Specifications** |**No.**<br>~~DO~~|**Items**<br>~~DO~~|**NBC-06-472**<br>~~DO~~|**NBC-10-472**<br>~~DO~~|**NBC-16-472**<br>~~DO~~|**NBC-20-472**<br>~~DO~~|**NBC-30-472**| |---|---|---|---|---|---|---| |**1**<br>~~po~~<br>~~a~~|**Rated Voltage[V]**<br>~~po~~<br>~~a~~|AC 1f250 / DC250<br>~~po~~||||| |**2**<br>~~po~~<br>~~a~~|**Rated Current[A]**<br>~~po~~<br>~~a~~|6<br>~~po~~|10|16|20|30| |**3**<br>~~a~~<br>~~po~~|**Test Voltage (Terminal-Mounting Plate)**<br>~~a~~<br>~~po~~|2,500 VAC(Cutoff Current = 20mA), 1minute at room temperature and humidity<br>~~po~~||||| |**4**<br>~~po~~|**Isolation Resistance(Terminal-Mounting Plate)**<br>~~po~~|500 VDC 100MWmin at room temperature and humidity<br>~~po~~||||| |**5**<br>~~po~~|**Leakage current 125/250V 60Hz**<br>~~po~~|0.5mA/1.0mA max<br>~~po~~||||| |**6**<br>~~po~~<br>~~po~~|**Voltage drop**<br>~~po~~<br>~~po~~|1.0V max<br>~~po~~<br>~~po~~||||| |**7**<br>~~po~~|**Safety agency approval temperatures**<br>~~po~~|-25 to +85C (Refer to DeratingCurve)<br>~~po~~||||| |**8**<br>~~po~~|**Operating temperature**<br>~~po~~|-40 to +85C (Refer to DeratingCurve)<br>~~po~~||||| |**9**<br>~~po~~|**Operating humidity**<br>~~po~~|20 to 95%RH(Non condensing)<br>~~po~~||||| |**10**<br>~~po~~<br>~~pO~~|**Storage temperature/humidity**<br>~~po~~<br>~~pO~~|-40 to +85C/20 to 95%RH(Non condensing)<br>~~po~~<br>~~pO~~||||| |**11**<br>~~pO~~|**Vibration**<br>~~pO~~|10 to 55Hz, 19.6m/s2 (2G), 3min. Period, 1hour each X, Y and Z axis<br>~~pO~~||||| |**12**<br>~~pO~~|**Impact**<br>~~pO~~|196.1m/s2 (20G), 11ms Once each X, Y and Z axis<br>~~pO~~||||| |**13**<br>~~po~~|**Safety agency approvals**<br>~~po~~|UL1283, CSA C22.2 No.8(C-UL), DIN EN60939 VDE0565 Teil3-1, ENEC(At onlyAC input)<br>~~po~~||||| |**14**<br>~~po~~<br>~~pO~~|**Case size(withoutprojection) /Weight**<br>~~po~~<br>~~pO~~|53X41X92 mm [2.09X1.61X3.62 inches](WXHXD)/270gmax(Option : -D refer to external view)<br>~~po~~<br>~~pO~~||||| ## **Circuit Diagram** ## **Derating Curve** **==> picture [17 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> Case<br>**----- End of picture text -----**<br> **==> picture [208 x 96] intentionally omitted <==** **----- Start of picture text -----**<br> 1 3<br>e CY CY oe<br>LINE a LOAD<br>CY<br>2 e age r 4<br>2¢ oF uyte D—4<br>CY : Line to ground capacitor : Mounting Plate<br>“GY Line to ground capacitor =; Mountng Plate<br>**----- End of picture text -----**<br> **==> picture [202 x 98] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>80<br>60<br>40<br>20<br>FEEGRPNE<br>0 || [ot] | tt| | TetTit |FATI<br>-40 -30 -20 40 50 55 60 70 80 90<br>Ambient Temperature [C]<br>Load Factor [%]<br>**----- End of picture text -----**<br> **NF-48** ## **NBC,NBM series** ## **External view** **As this product is adopted push-down type terminal block, this appearance is as follows.** 1 **The terminal cover is retracted inside the unit.** 2 **The screws for connecting the terminals are held in the up right position.** **==> picture [477 x 238] intentionally omitted <==** **----- Start of picture text -----**<br> Standard Type<br>92<br>[3.62]<br>82 ±0.5 2.5 30.5<br>2-[0.19]f4.8 80[3.23] 2-Protection Earth [0.1] [1.2] 8<br>Mounting Hole [3.15] [0.31]<br>Input<br>Terminal<br>Output<br>Name Plate Terminal<br>Output<br>Input Terminal<br>Terminal<br>6-M4<br>Terminal cover Terminal cover Mounting Plate<br>¶ Closed the terminal cover<br>¶ Tolerance : ±1 [±0.04]<br>¶ Weight : 270g max<br>¶ Mounting Plate : Iron (surface finishing:nickel plating) t=1.0 [0.04]<br>¶ Case : PBT<br>¶ Dimensions in mm, [ ]=inches<br>¶ Terminal block screw tightening torque M4:1.6N-m (16.9kgf- Terminal block screw tightening torque M4:1.6N-m (16.9kgf--m (16.9kgf-m (16.9kgf--cm) max<br>0.5<br>± [1.77]<br>45<br>15 [0.59] 53 [2.09]<br>12 [0.47]<br>2 [0.08]<br>41 [1.61]<br>**----- End of picture text -----**<br> **==> picture [199 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> ¶ Terminal block screw tightening torque M4:1.6N-m (16.9kgf- Terminal block screw tightening torque M4:1.6N-m (16.9kgf--m (16.9kgf-m (16.9kgf--cm) max<br>**----- End of picture text -----**<br> ## **DIN rail installation Type** **==> picture [494 x 236] intentionally omitted <==** **----- Start of picture text -----**<br> 92 8.2 ±1.5 2.5 30.5<br>[3.62] [0.32] [0.1] [1.2]<br>80 2-Protection Earth 8<br>[3.15] [0.31]<br>Input<br>Terminal<br>Output<br>Name Plate Terminal<br>Output<br>Input Terminal<br>Terminal<br>6-M4<br>Terminal cover Terminal cover Mounting Plate<br>¶ Closed the terminal cover<br>¶ Tolerance : ±1 [±0.04]<br>¶ Weight : 270g max<br>¶ Mounting Plate : Iron (surface finishing:nickel plating) t=1.0 [0.04]<br>¶ Case : PBT<br>¶ Dimensions in mm, [ ]=inches<br>¶ Terminal block screw tightening torque M4:1.6N-m (16.9kgf-cm) max<br>DIN rail<br>15 [0.59] 53 [2.09]<br>12 [0.47]<br>2 [0.08]<br>41 [1.61]<br>(9) [0.35]<br>7 [0.28]<br>**----- End of picture text -----**<br> ## ¡ **Note when installing the EMI/EMC Filter on a DIN rail.** **When the EMI/EMC Filter is grounded through the DIN rail, the proper noise attenuation may not be achieved.** **Be sure to connect the protection earth (PE) of the EMI/EMC Filter body to the earth. It can connect the ground to either one only.** **==> picture [170 x 92] intentionally omitted <==** **----- Start of picture text -----**<br> DIN rail<br>Name Plate<br>**----- End of picture text -----**<br> **NF-50**
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →