Image not available
Illustrative purposes only
MT4W-AV-4N
DIGITAL PANEL METER, 4-DIGIT, 100VAC TO 240VAC
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: AUTONICS
- Product type: Digital Panel Meters
- No. of Digits / Alpha:4; Meter Function:AC Voltage / Frequency; Meter Range:0V to 500V / 0.1Hz to 9.999KHz; Digit Height:14.2mm; Panel Cutout Height:45m 10R5270
- Meter Range: 0V to 500V / 0.1Hz to 9.999KHz
- Digit Height: 14.2mm
- Product Range: MT4W Series
- Meter Function: AC Voltage / Frequency
- Panel Cutout Width: 92mm
- Supply Voltage Max: 240VAC
- Supply Voltage Min: 100VAC
- Panel Cutout Height: 45mm
- No. of Digits / Alpha: 4
- Operating Temperature Max: 50°C
- Operating Temperature Min: -10°C
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 113.09 € |
| Current stock | 10+ |
| Lead time | 30 days |
**MT4Y/MT4W Series** **Multi Panel Meter** **(A) DIN W72×H36mm, W96×H48mm, Digital Multi Panel Meter Photoelectric Features Sensors (B)** ● Various input/output (default: indicator) **Fiber Optic** - Input: DC voltage, DC current, AC voltage, AC current ~~-~~ **Sensors** - Output: RS485 communication output, Low speed serial output, **(C)** transmission (DC4-20mA) output, BCD dynamic output, **Door/AreaSensors** NPN/PNP open collector output, relay output ● Maximum allowed input **(D) Proximity** : 500VDC, 500VAC, DC5A, AC5A **Sensors** ● Display range: -1999 to 9999 **(E)** ● High/low-limit display scale function **PressureSensors** ● AC frequency measurement (range: 0.1 to 9999Hz) ● Various functions: Monitoring peak display value function, **(F) Rotary** display cycle delay function, zero adjustment function, ~~-~~ **Encoders** high display correction function, transmission (DC4-20mA) output **(G)Connectors/** scale function etc. **Connector Cables/Sensor Distribution** ● Power supply: 12-24VDC, 100-240VAC 50/60Hz **Boxes/Sockets (H) Please read “Safety Considerations” in operation manual before using.** Cé We ~~=~~ **TemperatureControllers (I) SSRs / Power Ordering Information Controllers MT 4 W DV 4 N N** Indicator (without output function) **(J) Counters 0** Relay output **1** NPN open collector output **(K) MT4Y 2** PNP open collector output **Timers** 100-240VAC **3** ※1 Relay (low out)+transmission (DC4-20mA) output **4** ※1 Relay (low out)+RS485 communication output **(L) Panel 5** BCD dynamic output **Meters 6** Low speed serial output **(M)** Output 12-24VDC, **N** Indication type (no output function) **Tacho /Speed / PulseMeters** 100-240VAC **0** Relay+transmission (DC4-20mA) output **1** Relay output **(N)Display 2** NPN open collector+BCD dynamic output **Units MT4W 3** PNP open collector+BCD dynamic output **(O) 4** NPN open collector+transmission (DC4-20mA) output **SensorControllers 5** PNP open collector+transmission (DC4-20mA) output 100-240VAC **6** NPN open collector+low speed serial output **(P)Switching 7** PNP open collector+low speed serial output **Mode PowerSupplies 8** NPN open collector+RS485 communication output **(Q)** oo. ~~=~~ **9** PNP open collector+RS485 communication output ~~-~~ **Stepper Motors & Drivers** Power supply **1** ※2 12-24VDC ~~=~~ **& Controllers 4** 100-240VAC 50/60Hz **(R)Graphic/ Logic DV** DC voltage **Panels** Measuring input **DA** DC current **(S) Field AV** AC voltage **Network Devices AA** AC current Size **Y** DIN W72×H36mm **(T) Software W** DIN W96×H48mm ~~=~~ Digit **4** 9999 (4-digit) Item **MT** Multi meter ## **DIN W72×H36mm, W96×H48mm, Digital Multi Panel Meter** - Various input/output (default: indicator) - Maximum allowed input : 500VDC, 500VAC, DC5A, AC5A - Display range: -1999 to 9999 - High/low-limit display scale function - AC frequency measurement (range: 0.1 to 9999Hz) - Various functions: Monitoring peak display value function, display cycle delay function, zero adjustment function, high display correction function, transmission (DC4-20mA) output scale function etc. ● Power supply: 12-24VDC, 100-240VAC 50/60Hz - ※1: Only lST (preset output mode) setting is available in MT4Y-☐-43 (relay (low out)+transmission (DC4-20mA) output) and - MT4Y-☐-43 (relay (low out)+transmission (DC4-20mA) output) models. - ※2: Only for MT4W. ※To measure the current over DC5A, please select DV type because the shunt should be used. - ※In case of selecting frequency display, no output will be provided even if it is output support models. - (main output, sub output and RS485 communication output) L-35 ## **MT4Y/MT4W Series** ## **Specifications** |**Specifications**|**Specifications**||||||| |---|---|---|---|---|---|---|---| |Series||**MT4Y-DV-4**<br>**MT4Y-DA-4**|**MT4Y-AV-4**|**MT4W-DV-4**<br>|**MT4W-AV-4**|**MT4W-DV-1**|**MT4W-AV-1**<br>**MT4W-AA-1**| ||||**MT4Y-AA-4**|**MT4W-DA-4**<br>|**MT4W-AA-4**|**MT4W-DA-1**|| |Measurement input||DC voltage,<br>current|AC voltage,<br>current,<br>Frequency|DC voltage,<br>current<br> <br><br>|AC voltage,<br>current,<br>Frequency|DC voltage,<br>current|AC voltage,<br>current,<br>Frequency| |Power supply||100-240VACᜠ50/60Hz||||12-24VDCᜡ|| |Allowable voltage range||90 to 110%||||90 to 110%|| |Power consumption||5VA||||5W|| |Displaymethod||7-segment LED display (red) (character height: 14.2mm)|||||| |Display accuracy||• 23℃±5℃ - DC Type: F.S. ±0.1% rdg±2-digit / AC Type: F.S. ±0.3% rdg±3-digit (frequency: F.S.±0.1% rdg±2-digit)<br>DC/AC Type: F.S +0.3% rdg ±3-digit max. only for 5A terminal<br>• -10℃to 50℃ -DC/AC Type: F.S.±0.5% rdg±3-digit|||||| |Max. allowable input||110% F.S. for each measured input range|||||| |A/D conversion method||Practical oversamplingusingsuccessive approximation ADC|||||| |Samplingcycle||DC type: 50ms,AC type: 16.6ms|||||| |Max. displayrange||-1999 to 9999(4-digit)|||||| |Preset output||• Relay output - Contact capacity: 250VACᜠ3A, 30VDCᜡ3A / Contact composition: N.O (1a)<br>• NPN/PNP Open collector output - Max. 12-24VDCᜡ±2V 50mA(resistive load)|||||| |Sub output<br>(transmission output)||• RS485 communication output - Baud rate: 1,200/2,400/4,800/9,600, Communication method<br>: 2-wire half duplex, Synchronous method: Asynchronous method, Protocol: Modbus type<br>• Serial/BCD dynamic output - NPN Open collector output: 12-24VDC Max. 50mA (resistive load)<br>• DC4-20mA output - Resolution: 12,000 division(load resistance max. 600Ω),Response time: max. 450ms|||||| |AC measuringfunction※1||Selectable RMS or AVG|||||| |Frequencymeasurement function※1||Measurement range: 0.100 to 9999Hz(variable bydecimalpointposition)|||||| |Hold function※2||Includes(external hold function)|||||| |Insulation resistance||Over 100MΩ(at 500VDC megger,between external terminal and case)|||||| |Dielectric stength||2000VAC 50/60Hz for 1 min(between external terminal and case)|||||| |Noise immunity||±2kV the square wave noise(pulse width: 1㎲)bythe noise simulator|||||| |Vibration <br>|Mechanical|0.75mm amplitude at frequencyof 10 to 55Hz(for 1 min)in each X,Y,Z direction for 2 hours|||||| ||Malfunction|0.5mm amplitude at frequencyof 10 to 55Hz(for 1 min)in each X,Y,Z direction for 10 min|||||| |Shock<br><br>|Mechanical|100m/s²(approx. 10G)in each X,Y,Z direction for 3 times|||||| ||Malfunction|300m/s²(approx. 30G)in each X,Y,Z direction for 3 times|||||| |Relay<br>life cycle<br><br>|Malfunction|Min. 20,000,000 operations|||||| ||Mechanical|Min. 100,000 operations(250VAC 3A load current)|||||| |Environ<br>-ment<br> <br>|Ambient temperature|-10 to 50℃,storage: -20 to 60℃|||||| ||Ambient humidity|35 to 85%RH,storage: 35 to 85%RH|||||| |Insulation type||Double insulation or reinforced insulation<br>(mark:<br>,dielectric strength between the measuringinputpart and thepowerpart: 1kV)|||||| |Approval|||||||| |Weight※3||Approx. 213.5g (approx. 134g)||Approx. 326g (approx. 211g)|||| ※1: AC measuring function, and frequency measuring function are only for AC measuring input type. - ※2: MT4Y-4N model has no hold function. - ※3: The weight includes packaging. The weight in parenthesis is for unit only. ※Environment resistance is rated at no freezing or condensation. ## **Unit Description** ## **● MT4Y Series** **==> picture [111 x 53] intentionally omitted <==** **----- Start of picture text -----**<br> 1<br>2 6<br>3<br>4 5<br>**----- End of picture text -----**<br> **==> picture [117 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> 1. HI: High output indication of preset<br>**----- End of picture text -----**<br> **2. GO:** GO output indication of preset **3. LO:** Low output indication of preset ## **● MT4W Series** **==> picture [137 x 59] intentionally omitted <==** **----- Start of picture text -----**<br> 1<br>2 6<br>3<br>4 5<br>**----- End of picture text -----**<br> **4.** MODE **key:** mode key **5. key:** moves digit, enters parameter mode, **key:** changes sv **6. unit label part** - ※There is no **1** , **2** , **3** on a display panel of MT4Y-4N, 45, 46 and MT4W-4N. - ※In MT4Y3, 4, OUT is used for Go output display and there is no **1** , **3** in display panel. L-36 **Multi Panel Meter** **(A) Photoelectric Sensors (B) Fiber Optic Sensors (C) Door/Area Sensors (D) Proximity Sensors** **(E) Pressure Sensors** **(F) Rotary Encoders** ## **Connections** **==> picture [436 x 423] intentionally omitted <==** **----- Start of picture text -----**<br> Measuring input connection of MT4Y Series<br>● MT4Y-DV-4 ● MT4Y-AV-4<br>1 2 3 4 5 6 7 1 2 3 4 5 6 7<br>250mV 2V/1V<br>/50mV<br>5V/1V SOURCE 20V/10V SOURCE<br>50V/10V 100-240VAC50/60Hz 5VA 110V/50V 100-240VAC50/60Hz 5VA<br>500V/100V 500V/250V<br>● MT4Y-DA-4 ● MT4Y-AA-4<br>1 2 3 4 5 6 7 1 2 3 4 5 6 7<br>5mA 100mA<br>/2mA /50mA<br>50mA/ SOURCE 500mA SOURCE<br>4-20mA 100-240VAC /250mA 100-240VAC<br>500mA/200mA 50/60Hz 5VA 1A 50/60Hz 5VA<br>5A/2A 5A/2.5A<br> Output terminal of connection of MT4Y Series<br>●MT4Y- -4N (indicator) ●MT4Y- -40 (triple relay output) ●MT4Y- -41<br>(triple NPN open collector output)<br>8 9 10 11 12 13<br>8 9 10 11 12 13<br>Hold/Zero<br>1 2 3 4 5 6 7 HI GO LO COM Hold/Zero<br>CONTACT OUT HI GO LO COM<br>: 250VAC 3A 1a, 30VDC 3A 1a RESISTIVE LOAD<br>●MT4Y- -42 ●MT4Y- -43 ●MT4Y- -44<br>(triple PNP open collector output) (relay+transmission (DC4-20mA) output) (relay+RS485 communication output)<br>8 9 10 11 12 13 8 9 10 11 12 13 8 9 10 11 12 13<br>+ - B (-) A (+)<br>Hold/Zero DC4-20mALoad OUT1 Hold/Zero OUT1 Hold/Zero<br>HI GO LO COM 600Ω max. CONTACT OUT RS485 CONTACT OUT<br>: 250VAC 3A 1a, 30VDC 3A 1a : 250VAC 3A 1a, 30VDC 3A 1a<br>RESISTIVE LOAD RESISTIVE LOAD<br>●MT4Y- -45 (BCD dynamic output) ●MT4Y- -46 (low speed serial output)<br>Hold/Zero PCB 8 9 10 11 12 13<br>A C D0 D2 Dot<br>2 4 6 8 10 12 14 Hold/Zero<br>CLOCK DATA LATCH POL COM<br>1 3 5 7 9 11 13 ※POL: When a display value is "-",<br>COM B D D1 D3 POL the signal of "-" will be outputted.<br>※Hirose connector pin header model of the unit: HIF3BA-14PA-2.54DS<br>※ Contact Hirose Electric to purchase socket and wires of Hirose connector.<br>[Socket: HIF3BA-14D-2.54R]<br>**----- End of picture text -----**<br> ## **Measuring input connection of MT4W Series** **==> picture [372 x 157] intentionally omitted <==** **----- Start of picture text -----**<br> ● MT4W-DV- ● MT4W-AV-<br>1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9<br>250mV 2V/1V<br>/50mV + - + -<br>5V/1V Hold/Zero 20V/10V Hold/Zero<br>50V/10V SOURCE 110V/50V SOURCE<br>12-24VDC 5W 12-24VDC 5W<br>500V/100V COM 100-240VAC 500V/250V COM 100-240VAC<br>50/60Hz 5VA 50/60Hz 5VA<br>● MT4W-DA- ● MT4W-AA-<br>1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9<br>5mA 100mA<br>/2mA + - /50mA + -<br>50mA/ Hold/Zero 500mA Hold/Zero<br>4-20mA SOURCE /250mA SOURCE<br>500mA/200mA 12-24VDC 5W 1A 12-24VDC 5W<br>5A/2A 100-240VAC 5A/2.5A 100-240VAC<br>COM 50/60Hz 5VA COM 50/60Hz 5VA<br>**----- End of picture text -----**<br> **(G) Connectors/ Connector Cables/ Sensor Distribution Boxes/Sockets (H) Temperature Controllers (I) SSRs / Power Controllers (J) Counters (K) Timers (L) Panel Meters (M) Tacho / Speed / Pulse Meters (N) Display Units (O) Sensor Controllers (P) Switching Mode Power Supplies (Q) Stepper Motors & Drivers & Controllers (R) Graphic/ Logic Panels (S) Field Network Devices (T) Software** L-37 **MT4Y/MT4W Series** ## **Output terminal connection of MT4W Series** **==> picture [437 x 186] intentionally omitted <==** **----- Start of picture text -----**<br> ● MT4W- - 0 (triple relay+transmission (DC4-20mA) output) ● MT4W- - 1 (triple relay output)<br>MAIN OUT MAIN OUT<br>CONTACT OUT CONTACT OUT<br>: 250VAC 3A 1a, 30VDC 3A 1a RESISTIVE LOAD : 250VAC 3A 1a, 30VDC 3A 1a RESISTIVE LOAD<br>10 11 12 13 14 15 10 11 12 13 14 15<br>+ -<br>DC4-20mA HI GO LO<br>HI GO LO COM Load 600Ω Max.<br>1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9<br>PCB<br>1 2 3 4 5 6 7 8 9 ※Hirose connector pin header model of the unit: HIF3BA-20PA-2.54DS<br>※Contact Hirose Electric to purchase socket and wires of Hirose connector.<br>[Socket: HIF3BA-20D-2.54R]<br>**----- End of picture text -----**<br> - **MT4W2 / MT4W3** (triple NPN/PNP open collector+BCD dynamic output) ||||**GO**|**GO**||||+24VDC<br>30mA Max.|+24VDC<br>30mA Max.|+24VDC<br>30mA Max.|+24VDC<br>30mA Max.|**B**||**D1**<br>**D**||**D3**||**COM2**<br>**DOT**|**COM2**<br>**DOT**|**COM2**<br>**DOT**|**COM2**<br>**DOT**|**COM2**<br>**DOT**|||**GO**|**GO**|**GO**||||+24VDC<br>30mA Max.|+24VDC<br>30mA Max.| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| |||||||||||||||||||||||||||||||||| |**MAIN OUT:**<br>**NPN OPEN COLLECTOR**<br>12-24VDC Max. 50mA|||**1**<br>**2**||**3**<br>**4**||**5**<br>**6**||**7**<br>**8**|||**9**<br>**10**||**11**<br>**13**<br>**12**<br>**14**||**15**<br>**16**|||**17**<br>**18**||**19**<br>**20**||**MAIN OUT:**<br>**PNP OPEN COLLECTOR**<br>12-24VDC Max. 50mA||**1**<br>**2**|||**3**<br>**4**|||**5**<br>**7**<br>**6**<br>**8**|| |||||||||||||||||||||||||||||||||| ||**COM1**|||**HI**|**LO**||||0V|||**A**||**BCD OUT:**<br>**C**<br>**D0**<br>**D2**||||||**POL**|||**COM1**|||**HI**|||**LO**||0V|| |||||||||||||||**NPN OPEN COLLECTOR**<br>12-24VDC Max. 50mA|||||||||※POL: When a display value is<br>outputted.|"-", the||signal||||of|"-" will be|| ## **● MT4W4 / MT4W5** (triple NPN/PNP open collector+transmission (DC4-20mA) output) **==> picture [419 x 72] intentionally omitted <==** **----- Start of picture text -----**<br> +24VDC +24VDC<br>GO 30mA Max. (-) GO 30mA Max.<br>MAIN OUT: 2 4 6 8 10 12 14 16 18 20 MAIN OUT: 2 4 6 8<br>NPN OPEN COLLECTOR PNP OPEN COLLECTOR<br>12-24VDC Max. 50mA 12-24VDC Max. 50mA<br>1 3 5 7 9 11 13 15 17 19 1 3 5 7<br>COM1 HI LO 0V Current: (+) COM1 HI LO 0V<br>DC4-20mA LOAD 600Ω Max.<br>**----- End of picture text -----**<br> ## **● MT4W6 / MT4W7 (** triple NPN/PNP open collector+low speed serial output) |**T4W-**<br>**-**<br>**6 / MT4W-**||**-**<br>**7 **|**-**<br>**7 **|**(**tr|ipl|e|NPN/P|NPN/P|NPN/P|NPN/P|NPN/P|NP|open collector+low speed serial output)|open collector+low speed serial output)|open collector+low speed serial output)|open collector+low speed serial output)|open collector+low speed serial output)|open collector+low speed serial output)|open collector+low speed serial output)|open collector+low speed serial output)||||||||||||| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| |||**GO**|||||+24VDC<br>30mA Max.||||||※POL: When a display value is "-", the signal of "-" will be<br>outputted.<br>**CLOCK**<br>**POL**<br>**LATCH**|||||||||**GO**||||||+24VDC<br>30mA Max.||||| |||||||||||||||||||||||||||||||||| |**MAIN OUT:**<br>**NPN OPEN COLLECTOR**<br>12-24VDC Max. 50mA||**1**<br>**2**||**3**<br>**4**||**5**<br>**6**|||**7**<br>**8**|||**9**<br>**10**||**11**<br>**12**||**13**<br>**14**|**15**<br>**17**<br>**16**<br>**18**|**19**<br>**20**||**MAIN OUT:**<br>**PNP OPEN COLLECTOR**<br>12-24VDC Max. 50mA||**1**<br>**2**|||**3**<br>**4**|||**5**<br>**6**||**7**<br>**8**||| |**COM1**|||**HI**|**LO**|||||0V||||||||**SERIAL OUT:**<br>**COM2**<br>**DATA**||||**COM1**||**HI**|||**LO**||||0V||| ||||||||||||||||||**NPN OPEN COLLECTOR**|||||||||||||||| ||||||||||||||||||12-24VDC Max.||50mA|||||||||||||| ## **● MT4W8 / MT4W9** (triple NPN/PNP open collector+RS485 communication output) **==> picture [418 x 86] intentionally omitted <==** **----- Start of picture text -----**<br> +24VDC RS485 +24VDC<br>GO 30mA Max. B (-) SG GO 30mA Max.<br>MAIN OUT: MAIN OUT:<br>NPN OPEN COLLECTOR 2 4 6 8 10 12 14 16 18 20 PNP OPEN COLLECTOR 2 4 6 8<br>12-24VDC Max. 50mA 12-24VDC Max. 50mA<br>1 3 5 7 9 11 13 15 17 19 1 3 5 7<br>COM1 HI LO 0V A (+) SG ※SG (Signal Ground) COM1 HI LO 0V<br>RS485 : Signal ground is the terminal which is base of<br>the signal voltage. It is connected with terminal 7<br>inside of the product.<br>**----- End of picture text -----**<br> L-38 **Multi Panel Meter** **==> picture [481 x 542] intentionally omitted <==** **----- Start of picture text -----**<br> Dimensions (A)<br>(unit: mm) Photoelectric Sensors<br>● MT4Y- -4N, 45, 46<br>(B)<br>85 Fiber<br>Optic<br>72 6 77 Sensors<br>(C)<br>● Panel cut-out Door/AreaSensors<br>Min. 91<br>(D)<br>Proximity<br>Sensors<br><MT4Y- -4N, 40 to 44, 46> + 0.7<br>● MT4Y- -43, 44 68 0 (E) Pressure<br>Sensors<br>(F)<br>Rotary<br>6 77 10 Pin Hirose connector Encoders<br> (HIF3BD-10PA-2.54DS) (G)<br>Connectors/<br>● MT4Y- -40, 41, 42 Connector Cables/Sensor Distribution<br>Boxes/Sockets<br>(H)<br>Temperature<br><MT4Y- -45> Controllers<br>(I)<br>SSRs / Power<br>Controllers<br>● MT4W- - N (indicator)<br>(J)<br>109 106 ● Panel cut-out Counters<br>96 6 89.5 Relay contact Min. 116<br>output terminal (K)<br>Timers<br>(L)<br>Panel<br>92 + 0.8 0 Meters<br>(M)<br>Tacho /<br>※There is no Relay output terminal block in Speed / PulseMeters<br>indication type.<br>< MT4W- - N, MT4W- - 0, 1 > (N)Display<br>● MT4W- - 0 to 9 Units<br>110.4<br>6 89.5 (O)Sensor<br>20 Pin Hirose connector Controllers<br> (HIF3BA-20PA-2.54DS)<br>(P)<br>Switching<br>Mode Power<br>Supplies<br>(Q)<br>Stepper Motors<br>& Drivers<br>& Controllers<br>< MT4W- - 2 to 9 ><br>(R)<br>Graphic/<br>Logic<br> Parameter Setting Panels<br>(S)<br>RUN ※Press MODE key in RUN mode and it enters PA 0 group. FieldNetwork<br>※Press MODE key for over 3 sec in RUN mode, it displays [ PA1 ]. Devices<br> 3 sec 3 sec ※Press MODE key for over 5 sec in RUN mode, it displays [ PA2 ] after [ PA1 ].<br>When pressing MODE key continually, it stops displaying at [ PA2 ]. (T) Software<br>※It is advanced to current display parameter releasing MODE key at [ PA1 ] or [ PA2 ].<br>36 30<br>+ 0.531.5 0<br>Min. 40<br>30<br>+ 0.6 0<br>45<br>48 44.8<br>Min. 52<br>44.8<br>**----- End of picture text -----**<br> **==> picture [124 x 111] intentionally omitted <==** **----- Start of picture text -----**<br> RUN<br> 3 sec<br>3 sec<br>PA 0 PA1<br>2 sec<br>PA2<br> 3 sec<br>**----- End of picture text -----**<br> - ※Press MODE key for over 3 sec in any parameter groups, it returns to **RUN** mode. - ※If any key is not entered for 60 sec in each parameter, it returns to **RUN** mode. - ※After returning to **RUN** mode, press MODE key within 2 sec, it returns to previous parameter. (Refer to the below descriptions of each parameter group.) - ※ **PA 0** group cannot be entered when preset output mode of [ PA2 ] group is OFF[.] L-39 **MT4Y/MT4W Series** ## **Parameter 1 Group** **==> picture [442 x 484] intentionally omitted <==** **----- Start of picture text -----**<br> RUN<br> 3 sec<br>PA1 ● Measuring input chart by model<br>Item Range of measuring input<br>MT4Y/W-DV 500V 100V 50V 10V 5V 1V )25V 50ㅡMV 500V<br>IN-R Display of factory measuring inputdefault for Select measuring input specification by - Refer to " Measurement Input" . . MT4Y/W-DAMT4Y/W-AV 5A 500V 2A 250V)5A 110P)2A (※) 50MA 50V 4-20MA 20V 10V5MA 2V2MA 1V 5A500V<br>MT4Y/W-AA 5A 2.5A 1A )5A )25A )1A 50mA 5A<br>※Standard specification. (110P is 440VAC/110VAC P.T)<br>DISP STND<br>- Refer to " Measurement Input" .<br> ( FREQ mode is only for AC measuring type.)<br>IN-T AVG Select measuring method for AC.Setting range: AVG , RMS (average: AVG, root mean square: RMS)<br>(This parameter will be displayed only for AC measuring models. In case<br>of selecting frequency display, it will not be displayed.)<br>When DISP is STND When DISP is SCAL When DISP is FREQ<br>(It is only displayed for AC measuring type.)<br>STND Max. displayvalue DOT Decimal pointposition Select decimal point position.Setting range DOT Decimal pointposition Set frequency measuringrange, it is decided as<br>: ※ 0 When selecting the decimal , )0 , )00 , )000 the decimal point position.( change the<br>point position, " H-SC ", L-SC " have decimal point position)<br>It shows Max. display decimal point position.<br>value of standard 0 1 to 9999Hz<br>specification. )0 0.1 to 999.9Hz<br>Display value is fixed. Max. display Set display value against<br>H-SC value max. measuring input. )00 0.10 to 99.99Hz<br> ( : shift the digit )000 0.100 to 9.999Hz<br>: change setting value) ※In case of selecting frequency display, no<br>output will be provided even if it is output<br>support models (main output, Sub output<br>and RS485 communication output).<br>Set display value against<br>L-SC Min. displayvalue min. measuring input.<br> ( : shift the digit<br>: change setting value)<br>It corrects a gradient of High-limit display value against max. input. It corrects a gradient of display<br>INbH !000 Setting range: )100 to %000 (%) INbH !000 value against max.input.<br>( : change setting value, : shift the digit) Setting range: 0.001 to 9.999<br>( : shift the digit,<br>: change setting value)<br>INbL 00 It corrects deviation of Low-limit display value against Min. input. Setting range: -99 to 99 (Refer to " Zero adjustment " .) INbE 10-0 Set Setting range: 10-2 to 101<br>( : set a deviation value, : shift the digit) ( : shift the digit,<br>: change setting value)<br>※After setting each mode, press MODE key for 2 sec to return to RUN .<br>**----- End of picture text -----**<br> - ※If any key is untouched for 60 sec after advance to parameter, it will return to **RUN** . ## **Factory defaults** |Parameter|MT4Y/W-DV|MT4Y/W-DA|MT4Y/W-AV|MT4Y/W-AA|Parameter|MT4Y/W-DV|MT4Y/W-DA|MT4Y/W-AV|MT4Y/W-AA| |---|---|---|---|---|---|---|---|---|---| |IN-R|500V|SA|500V|SA|INbH|!000|!000|!000|!000| |DISP|STND|STND|STND|STND|INbL|00|00|00|00| |IN-T|~~-~~|~~-~~|AVG|AVG|DOT|)0|)000|)0|)000| |STND|50)0|%000|50)0|%000|INbE|~~-~~|~~-~~|10-0|10-0| L-40 **Multi Panel Meter** **==> picture [477 x 542] intentionally omitted <==** **----- Start of picture text -----**<br> Parameter 2 Group (A) Photoelectric<br>RUN Sensors<br> 5 sec (B)<br>Fiber<br>PA2 OpticSensors<br>Move after 1 sec<br>OUtT OFF Select preset output mode. (only for available models)Setting range: OFF , lST , hST , LhST , HhST , LlST , LdST (C) Door/AreaSensors<br>※Only lST setting is available in MT4Y-☐-43 and MT4Y-☐-44 models.<br>(D)<br>HYS 001 Set preset hysteresis. The range is within 10% of max. display range (unit: digit).※ OUtT mode is OFF , it is not displayed. ProximitySensors<br>(E)<br>Set startup compensation time. Pressure<br>STaT 0)0 ( : shift the digit, : change setting value) Sensors<br>Setting range: 0.0 to 99.9 sec<br>When initially supplying power, delays monitoring of high-limit/low-limit value of display value for the set time. (F) Rotary<br>PEkT 00 5 ( :shift the digit, : change setting value) Encoders<br>Setting range: 00 to 30 sec (G)<br>※ If it is set to 00 sec [ 00 S ], parameters of high-peak monitoring value [ hPEK ]/low-limit monitoring value [ lPEK ] in the Connectors/<br>parameter 0 group will be not displayed. Connector Cables/Sensor Distribution<br>D1sT )2 5 Set display cycle and also variable sets by 0.1 sec. ( : shift the digit, : change setting value) Boxes/Sockets<br>Setting range: 0.1 to 5.0 sec (H)<br>Temperature<br>Controllers<br>ZERO NO Select zero function with operation at front. (set with When + Key are pressed for 3 sec to set YES , it will be zero function and the deviation key) (I)<br>value is saved automatically at ㅡ INbL mode. SSRs / PowerControllers<br>Select input with 6, 7 (MT4W)[12, 13 (MT4Y)] terminal or zero function for external signal.<br>EV1N HOLD (set with , Key) (J)<br>HOLD : Holding display value, ZERO : Zero function using Hold/Zero terminal Counters<br>Set the high limit value, output point of current output 20mA.<br>FS-H 50)0 ( : shift the digit, : change setting value) (K)<br>(When changing measuring input and prescale mode, it is changed automatically Timers<br> as maximum value of input range.)<br>FS-L 00)0 Set the low limit value, output point of current output 4mA.( : shift the digit, : change setting value) (L) Panel<br>(When changing measuring input and prescale mode, it is changed automatically Meters<br> as minimum value of input range.)<br>(M)<br>ADRS 01 Set the address of RS485 communication output.( : shift the digit, : change setting value) Tacho /Speed / PulseMeters<br>Setting range: 01 to 99<br>(N)<br>Select Baud rate of RS485 communication output. Display<br>BPS 9600 Setting range: 9600 , 4800 , 2400 , 1200 Units<br>(O)<br>PRTY NONE Set parity bit of RS485 communication. Setting range: NONE , EVEN , ODD SensorControllers<br>(P)<br>Switching<br>Set stop bit of RS485 communication. Mode Power<br>STP 2 Setting range: 1 , 2 Supplies<br>(Q)<br>Stepper Motors<br>RSwT 5 Set response wait time of RS485 communication. Setting range: 5 to 99 & Drivers & Controllers<br>(R)<br>OFF [Disable to lock keys] Graphic/<br>Logic<br>LOC OFF Set key lock function and select from 4 types.Setting range: OFF , LOC1 , LOC2 , LOC3 LOC1 [Lock Parameter 1] Panels<br>LOC2 [Lock Parameter 1, 2] (S)<br>Field<br>LOC3 [Lock Parameter 0, 1 and 2] Network<br>Devices<br>The dotted mode is only displayed for output type.<br>After setting each mode, press MODE key for 2 sec to return to key for 2 sec to return to RUN mode. (T)<br>If any key is untouched for 60 sec after advance to parameter, it will return to RUN mode. Software<br>**----- End of picture text -----**<br> - ※The dotted mode is only displayed for output type. - ※After setting each mode, press MODE key for 2 sec to return to key for 2 sec to return to **RUN** mode. - ※If any key is untouched for 60 sec after advance to parameter, it will return to **RUN** mode. ## **Factory defaults** |Parameter|MT4Y/W-DV|MT4Y/W-DA|MT4Y/W-AV|MT4Y/W-AA|Parameter|MT4Y/W-DV|MT4Y/W-DA|MT4Y/W-AV|MT4Y/W-AA| |---|---|---|---|---|---|---|---|---|---| |OUtT|OFF|OFF|OFF|OFF|EV1N|HOLD|HOLD|HOLD|HOLD| |HYS|001|001|001|001|FS-H|50)0|%000|50)0|%000| |STAT|0)0|0)0|0)0|0)0|FS-L|00)0|)000|00)0|)000| |PEkT|00 5|00 5|00 5|00 5|ARDS|01|01|01|01| |DIsT|)2 5|)2 5|)2 5|)2 5|BPS|9600|9600|9600|9600| |ZERO|NO|NO|NO|NO|LOC|OFF|OFF|OFF|OFF| L-41 **MT4Y/MT4W Series** ## **Parameter 0 Group** |||**RUN**|**RUN**|**RUN**|||||Set preset High-limit value. (set with<br>,<br>,<br>key)<br>※It is displayed when set the preset only.<br>When setOFFinOUtTmode of the parameter 2 group, the parameter is not displayed.<br>Set preset Low-limit value. (set with<br>,<br>,<br>key)<br>※It is displayed when set the preset only.<br>When setOFFinOUtTmode of the parameter 2 group, the parameter is not displayed.<br>It shows High-limit monitoring value while it is in RUN mode.<br>It will be reset by pressing<br>,<br>,<br>key.<br>※hPEKparameter is not displayed whenPEkTparameter is set as 00 sec [00 5] at the parameter 2 group.<br>It shows Low-limit monitoring value while it is in RUN mode.<br>It will be reset by pressing<br>,<br>,<br>key.<br>※lPEKparameter is not displayed whenPEkTparameter is set as 00 sec [00 5] at the parameter 2 group.| |---|---|---|---|---|---|---|---|---|---| |||hSET||||50)0|||| ||||||||||| ||||||||||| |||lSET||||00)0|||| ||||||||||| ||||||||||| |||hPEK||||)0|||| ||||||||||| ||||||||||| |||lPEK||||)0|||| ||||||||||| ||||||||||| - ※If any key is untouched for 60 sec after advance to parameter, it will return to **RUN** mode. ## **Factory defaults** |Parameter|MT4Y/W-DV|MT4Y/W-DA|MT4Y/W-AV|MT4Y/W-AA|Parameter|MT4Y/W-DV|MT4Y/W-DA|MT4Y/W-AV|MT4Y/W-AA| |---|---|---|---|---|---|---|---|---|---| |hSET|50)0|%000|50)0|%000|hPEK|)0|)000|)0|)000| |lSET|00)0|)000|00)0|)000|lPEK|)0|)000|)0|)000| ## **Measurement Input** |Type|Measuring input and range|Input impedance|Display range [STND]|Prescale display range [SCAL]| |---|---|---|---|---| |DC voltage|0-500V<br>[500V]|4.33MΩ|0.0 to 500.0(fxed)|DOT<br>Display range<br>0<br>-1999 to 9999<br>)0<br>-199.9 to 999.9<br>)00<br>-19.99 to 99.99<br>)000<br>-1.999 to 9.999<br>(Display range is variable according<br>to decimal point position.)<br>※Please wire the proper terminal<br>to its max. input within 30 to<br>100% of the input terminal. When<br>it is higher than input, it may<br>cause terminal breakdown and<br>HHHHappears. The accuracy is<br>decreased when it is connected to<br>the terminal under 30%.<br>※In case of 0 to 110V [110P] of<br>AC voltage range and using<br>P.T (potential transformer) for<br>440V/110VAC, if 110V is input,<br>a nd the unit displays 440V<br>automatically by preset scale<br>value for P.T user's convenient.| ||0-100V<br>[100V]|4.33MΩ|0.0 to 100.0(fxed)|| ||0-50V<br>[50V]|433.15kΩ|0.00 to 50.00(fxed)|| ||0-10V<br>[10V]|433.15kΩ|0.00 to 10.00(fxed)|| ||0-5V<br>[5V]|43.15kΩ|0.000 to 5.000(fxed)|| ||0-1V<br>[1V]|43.15kΩ|0.000 to 1.000(fxed)|| ||0-250mV<br>[)25V]|2.15kΩ|0.0 to 250.0(fxed)|| ||0-50mV<br>[50MV]|2.15kΩ|0.00 to 50.00(fxed)|| |DC current|0-5A<br>[5A]|0.01Ω|0.000 to 5.000(fxed)|| ||0-2A<br>[2A]|0.01Ω|0.000 to 2.000(fxed)<br>|| ||0-500mA<br>[)5A]|0.1Ω|0.0 to 500.0(fxed)|| ||0-200mA<br>[)2A]|0.1Ω|0.0 to 200.0(fxed)|| ||0-50mA<br>[50MA]|1.0Ω|0.00 to 50.00(fxed)|| ||4-20mA<br>[4-20]|1.0Ω|4.00 to 20.00(fxed)|| ||0-5mA<br>[5MA]|10.0Ω|0.000 to 5.000(fxed)|| ||0-2mA<br>[2MA]|10.0Ω|0.000 to 2.000(fxed)|| |AC voltage|0-500V<br>[500V]|4.98MΩ|0.0 to 500.0(fxed)|| ||0-250V<br>[250V]|4.98MΩ|0.0 to 250.0(fxed)|| ||0-110V<br>[110P]|1.08MΩ|0.0 to 440.0(fxed)|| ||0-50V<br>[50V]|1.08MΩ|0.00 to 50.00(fxed)|| ||0-20V<br>[20V]|200kΩ|0.00 to 20.00(fxed)|| ||0-10V<br>[10V]|200kΩ|0.00 to 10.00(fxed)|| ||0-2V<br>[2V]|20kΩ|0.000 to 2.000(fxed)|| ||0-1V<br>[1V]|20kΩ|0.000 to 1.000(fxed)|| |AC current|0-5A<br>[5A]|0.01Ω|0.000 to 5.000(fxed)|| ||0-2.5A<br>[2.5A]|0.01Ω|0.000 to 2.500(fxed)|| ||0-1A<br>[1A]|0.05Ω|0.000 to 1.000(fxed)|| ||0-500mA<br>[)5A]|0.1Ω|0.0 to 500.0(fxed)|| ||0-250mA<br>[)25A]|0.1Ω|0.0 to 250.0(fxed)|| ||0-100mA<br>[)1A]|0.5Ω|0.0 to 100.0(fxed)|| ||0-50mA<br>[50MA]|0.5Ω|0.00 to 50.00(fxed)|| L-42 **Multi Panel Meter** **(A) Photoelectric Sensors (B) Fiber Optic Sensors** ~~-~~ **(C) Door/Area Sensors (D) Proximity Sensors (E) Pressure Sensors (F) Rotary Encoders (G) Connectors/ Connector Cables/ Sensor Distribution Boxes/Sockets (H) Temperature Controllers** ~~_~~ **(I) SSRs / Power Controllers (J) Counters** **(K) Timers** **(L) Panel Meters (M) Tacho / Speed / Pulse Meters (N) Display Units** ~~e~~ **(O) Sensor Controllers (P) Switching Mode Power Supplies (Q) Stepper Motors & Drivers & Controllers** **(R) Graphic/ Logic Panels** **(S) Field Network Devices (T) Software** ## **Sold Separately** ## **Communication converter** - **SCM-WF48 SCM-US48I** e **( Wi-Fi to RS485·USB wireless (USB to RS485 converter)** Ce **communication converter)** Ie c€ ke - **SCM-38I** e - **(RS232C to RS485 converter)** ## ~~©~~ **Display Units (DS/DA-T Series)** **DS/DA-T Series (RS485 communication input type display unit)** **==> picture [349 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> DS16- T DS22/DA22- T DS40/DA40- T DS60/DA60- T<br>**----- End of picture text -----**<br> ※Connect RS485 communication input type display unit (DS/DA-T Series) and RS485 communication output model of MT4Y/MT4W Series, the display unit displays present value of the device without PC/PLC. ## (mi **Functions** ## **AC frequency measurement** ## **[PA 1 group:** DISP **]** It measures input signal frequency when it is AC input. It uses fixed decimal point [ **PA1** : DOT ], measured range can be changed by setting and measured range of decimal point position is as below chart. It is available to adjust the upper gradient at [ **PA 1** : INbH ]and [ **PA 1** : INbE ]. In order to measure frequency normally, input signal, over 10% F.S. of the measured range, should be supplied. Please select the proper point of ## ① Measuring range |Decimal point<br>position|0.000|0.00|0.0|0| |---|---|---|---|---| |Measurement<br>range|0.100 to<br>9.999Hz|0.10 to<br>99.99Hz|0.1 to<br>999.9Hz|1 to<br>9999Hz| ※Accuracy of frequency measurement: Below 1kHz, F.S. ±0.1rdg ±2-digit. From 1kHz to 10kHz, F.S. ±0.3rdg ±2-digit. ② INbH : 0.100 to 9.999 [Gradient adjustment of high value] ③ INbE: 10-2, 10-1, 100, 101 [Index adjustment of INbH ] ## **Zero adjustment** ## **[Deviation correction function of low limit display value]** It adjusts the display value of the optional configured input value as zero by force, zero point error can be adjusted with 3 ways as below. When zero point adjustment with front key and Hold terminal is finished normally, zero point of measurement terminal is displayed and the adjusted value at saved in INbL automatically. |~~E~~||ee|ee| |---|---|---|---| |Operation <br>~~ee~~<br>~~E~~|Input correction<br>value<br>~~ee~~<br>~~y@)~~|Front panel<br>key<br>~~ee~~<br>ee<br>~~y@)~~|Input external signal<br>~~ee~~<br>ee<br>~~y@)od~~| |Description<br>~~E~~|PA 1: Direct<br>input correction<br>value method at<br>INbL.<br>~~y@)~~|Press<br>,<br>key for 3 sec<br>at the<br>RUN mode.<br>ee<br>~~y@)~~|Short-circuit external<br>Hold terminal 11,12<br>[6, 7 (MT4W)] over<br>min. 50m.<br>ee<br>~~y@)od~~| ## **Transmission (DC4-20mA) output scale [PA2 group: / ]** It sets transmission output for the display value at the output current DC4-20mA. It sets display value for 4mA at FS-L and 20mA at FS-H and the range between FS-H and FS-L should be 10% ※When min. set interval between FS-H and FS-L is set as under 10% F.S., it changed as over 10% F.S. automatically. ※Preset display value is fixed to output as 4mA at under FS-L and 20mA at over FS-H . **==> picture [151 x 71] intentionally omitted <==** **----- Start of picture text -----**<br> Output<br>20mA<br>Min.<br>4mA setting range<br>F.S. 10%<br>Display value<br>FS-L FS-H<br>**----- End of picture text -----**<br> L-43 Axons ~=~=~—COt=CSs=‘s—Ss~s=s‘s™s™S L-43 ## **MT4Y/MT4W Series** ## **Initialization** It initializes as the factory default status. If press , , keys together for 2 sec in **RUN** mode, INlT mode and the setting value ( NO ) is displayed every 0.5 sec and it will be initialized as the factory default when press MODE key after change NO → YES . ## **Startup compensation time** ## **[PA 2 group:** STAT **]** This time function limits the operation of an output until the measured input (overvoltage or inrush current) is stable at moment of power on. All outputs are off during startup compensation time setting after power is applied. Setting range: 00.0 to 99.9 (unit: sec) Factory default: 00.0 ## **Error display** |Display|Description| |---|---| |HHHH<br> <br>|Flashes when measuring input is exceeded the max.<br>allowable input(110%)| |LLLL<br> <br>|Flashes when measuring input is exceeded the max.<br>allowable input(-10%)| |D-HH<br> <br>|Flashes when display input is exceeded the max.<br>displayrange(9999)| |D-LL<br> <br>|Flashes when display input is exceeded the min.<br>displayrange(-1999)| |F-HH<br> <br>|Flashes when measuring frequency is exceeded the max.<br>measuringvalue(9999)| |OVER<br>|Flashes when it exceeds zero adjustment range(±99)| - ※Error display is released automatically when it is in the measured and display range. - ※" LLLL " is displayed when the measuring input is DC4-20mA. - ※ After flashing " OVER " 2 times when it exceeds the zero adjustment range, it returns to RUN mode. ## **Display scale [PA 1 group:** H-SC **/** L-SC **]** This function is to display setting (-1999 to 9999) of particular High/Low-limit value in order to display High/Lowlimit value of measured input. If measured inputs are 'a' and 'b' and particular values are 'A' and 'B', it will display a=A, b=B as below graphs. **==> picture [207 x 90] intentionally omitted <==** **----- Start of picture text -----**<br> Display B Display B Display B<br>value A value A value<br>a b<br>a b a b A<br>Input value Input value Input value<br>Display A a b A<br>value Display A a b<br>B value Display<br>value<br>a b B B<br>Input value Input value Input value<br>**----- End of picture text -----**<br> ## **Gradient correction [PA 1 group:** INbH **]** This function is to correct a gradient of prescale value and display value. (Fig.1) Display value Y can be used as α, β times against X input value by correction function [ INbH ]. And also can be used as correction function of max. display value ( H-SC ). Adjustment range is 0.100 to 5.000 and multiply current gradient. E.g.) Input: DC200mV, Display: 3.000 for MT4W-DV **==> picture [212 x 237] intentionally omitted <==** **----- Start of picture text -----**<br> Display value for<br>measuring input<br>αY 15.000<br>α time 12.000<br>Y 9.000<br>β time 6.000<br>βY<br>3.000<br>1.000 Input<br>0 X Input 0.2 0.40.60.8 1V value<br>value<br> (Fig. 1) (example of gradient correction)<br>① Select 0-1VDC[ 1V ] for measuring input in Parameter1.<br>② Standard specification in input: 0-1VDC and 1.000<br>therefore it has to be 15.000 ( H-SC ) for 1VDC (input)<br>in order to display 3.000 for DC200mV (input). But it is<br>disable due to setting range is 9.999<br>③ In this case, please check below chart.<br>Please set as INbH × H-SC =15.000<br>Setting H-SC L-SC INbH Other<br>① Disable 0.000 1.000 -<br>② 7.500 0.000 2.000<br>③ 5.000 0.000 3.000 In this case, any setting<br>methods display the<br>④ 3.750 0.000 4.000<br>same display value.<br>⑤ 3.000 0.000 5.000<br>Display value Display value<br>**----- End of picture text -----**<br> **Error correction [PA 1 group:** INbH **/** INbL **]** It corrects display value error of measured input. INbL[: ±99 [Adjust deviation of low value]] INbH[: 5.000 to 0.100 [Correct gradient (%) of high value]] Display value= (measured value × INbH ) + INbL E.g.) When the measured range is 0 to 500V, and the display range is 0 to 500.0. If the low display value is " 1.2 " to 0V input, set -12 as INbL value to display " )0 " by adjusting offset of the low value. The display value to 500V measured input varies by adjusting the offset of low value. If this display value is " 501.0 ", calculate 500.0/501.0 (desired display value/the display value), and set the 0.998 correction value as the INbH to display 50)0 by adjusting gradient of high value. ※The offset correction range of INbL is within -99 to 99 for D-0, D-1 digit regardless of decimal point. ## **Display cycle delay [PA 2 group:**[D1sT] **]** In some applications the measured input may fluctuate which in turn causes the display to fluctuate. By adjusting the display cycle delay function time in the D1sT of parameter 2, the operator can adjust the display time within a range of 0.1 sec to 5 sec. For example, if the operator sets the display cycle time to 4.0 sec, the display value displayed will be the average input value over 4 sec and also will show any changes if any every 4 sec. L-44 **Multi Panel Meter** **(A) Photoelectric Sensors** **(B) Fiber Optic Sensors** **(C) Door/Area Sensors** **(D) Proximity Sensors** **(E) Pressure Sensors (F) Rotary Encoders** **(G) Connectors/ Connector Cables/ Sensor Distribution Boxes/Sockets** **(H) Temperature Controllers** **(I) SSRs / Power Controllers** **(J) Counters** **(K) Timers** **(L) Panel Meters** **(M) Tacho / Speed / Pulse Meters** **(N) Display Units** **(O) Sensor Controllers** **(P) Switching Mode Power Supplies** **(Q) Stepper Motors & Drivers & Controllers (R) Graphic/ Logic Panels (S) Field Network Devices** **(T) Software** ## **Monitoring peak display value** ## **[PA 0 group:** hPEK **/** lPEK **, PA 2 group:** PEkT **]** It monitors max./min. value of display value based on the current displays value and then displays the data at hPEK , lPEK of parameter 0. Set the delay time (0 to 30 sec) at PEkT of parameter 2 in order to prevent malfunction caused by initial overcurrent or overvoltage, when monitoring the peak value. Delay time is 0 to 30 sec and it starts to monitor the peak value after the set time. When pressing any one of keys at hPEK , lPEK of parameter 0, the monitored data is initialized. - ※ hPEK **,** lPEK parameters is not displayed when monitoring delay time [ PEkT ] of parameter 2 group is set as 00 sec [ 00 S ]. ## **Preset output operation mode** ## **[PA 2 group:** OUtT **]** **==> picture [212 x 249] intentionally omitted <==** **----- Start of picture text -----**<br> Mode Output operation Operation<br>H<br>H: Hysteresis<br>OFF No output<br>If it is equal or smaller than low<br>lST GO setting value, LO output will be ON.<br>LO H If it is bigger than low setting value,<br>GO output will be ON.<br>If it is equal or bigger than high<br>hST HI H setting value, HI output will be ON.<br>GO If it is equal or smaller than high<br>setting value, GO output will be ON.<br>If it is equal or smaller than low<br>HI H setting value and equal or bigger<br>LhST GO than high setting value, the output will be ON. If it is bigger than Low<br>LO H setting value and smaller than high setting value, GO output will be ON.<br>If it is equal or bigger than low set<br>HI H and equal or bigger than high set<br>HhST GO value, output will be ON. If it is smaller than low setting value and<br>LO H high setting value, GO output will<br>be ON.<br>If it is equal or smaller than low<br>HI H setting value, LO output will be ON.If it is equal or smaller than high<br>LlST GO setting value, HI output will be ON.<br>LO H If it is bigger than low setting value and High setting value, GO output<br>will be ON.<br>This operation is the same as lST<br>GO But it doesn't operate at initial low<br>LdST LO H set value, it will operate at next low set value. If this is higher than low<br>set value, Go output will be ON.<br>**----- End of picture text -----**<br> - ※"H" means hysteresis and able to set 1 to 99 at " HYS " mode in **PA 2** among above comparison output chart. - ※ hSET is displayed according to the setting of output operation mode, when user sets " OFF ", hSET / lSET are not displayed. - ※Only lST setting is available in MT4Y-☐-43 and MT4Y-☐-44 models. ## **Sub output** - RS485 communication output - It is able to set address (01 to 99) - It is able to transmit by selecting modulation speed (transmitted number of signal per 1 sec) of serial trans -mission. (selectable 1200, 2400, 4800, 9600bps) - Low-speed serial output - It outputs current display value as Low-frequency (50Hz) type. - Transmission (DC4-20mA) output It outputs DC4-20mA against High/Low-limit scale. (resolution: 12000 division) - BCD dynamic output - It outputs display value as BCD Code. - ※ **Only one sub-output is selectable.** **(More than one sub-output is not allowed.)** ## **Time chart of BCD dynamic output and Serial output** - BCD dynamic output (negative logic) **==> picture [217 x 426] intentionally omitted <==** **----- Start of picture text -----**<br> t<br> t: 7.8ms<br>ta tw tb ta: 0.5ms<br>tw: 5ms<br>Digit signal<br>tb: 2.3ms<br>Input Data Data<br>31.2ms<br>D3<br>D2<br>Digit<br>D1<br>D0<br>A H L H L H<br>B H L L H H<br>Data C L H H H H<br>D H H H H H<br>dot H H L H H<br>Display<br>● Serial output (negative logic)-Clock frequency:50Hz<br>tw t: 20ms<br>ta: 0.05ms<br>tw: 5ms<br>Latch tb: 4.95ms<br>t ta tb<br>Clock Cn-1 Cn C1<br>Data Dn-1 Dn D1<br>Input<br>ordering 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 1 2<br>DP D C B A DP D C B A DP D C B A DP D C B A DP D<br>Clock<br>Data H H L H H H H H L L L H H L H H H H H L<br>tw<br>ta tb<br>Latch<br>Display<br>**----- End of picture text -----**<br> L-45
Updated at June 9, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →