Image not available
Illustrative purposes only
MPS-30-27
AC/DC Open Frame Power Supply (PSU), Medical, 1 Output, 29.7 W, 88V AC to 264V AC, Fixed
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC Open Frame Power Supplies
- SVHC: No SVHC (12-Jan-2017)
- Product Range: MPS-30 Series
- No. of Outputs: 1 Output
- Input Voltage VAC: 88V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 1.1A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 27VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: Medical
- Power Rating (Forced Cooling): -
- Power Rating (Convection Cooling): 29.7W
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 26.58 € |
| Current stock | 10+ |
| Lead time | 30 days |
**MPS - 30 series** MEAN WELL 30W Single Output for Medical Type **- series** ~~a~~ ## ■ ## **SPECIFICATION** |**SPECIFICATION**<br>~~+~~<br>CBCE|**SPECIFICATION**<br>~~+~~<br>CBCE||||~~+~~||CBCE| |---|---|---|---|---|---|---|---| |**MPS-30-5**<br>**MPS-30-12**<br>**MPS-30-15**<br>**MPS-30-24**<br>**MPS-30-27**<br>**MPS-30-48**<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**OVER TEMPERATURE**<br>**AC CURRENT (Typ.)**<br>5V<br>12V<br>15V<br>24V<br>27V<br>48V<br>5A<br>2.5A<br>2A<br>1.2A<br>1.1A<br>0.6A<br>0 ~ 5A<br>0 ~ 2.5A<br>0 ~ 2A<br>0 ~ 1.2A<br>0 ~ 1.1A<br>0 ~ 0.6A<br>25W<br>30W<br>30W<br>28.8W<br>29.7W<br>28.8W<br>80mVp-p<br>120mVp-p<br>150mVp-p<br>240mVp-p<br>240mVp-p<br>240mVp-p<br>±3.0%<br>±3.0%<br>±3.0%<br>±3.0%<br>±3.0%<br>±2.0%<br>±1.0%<br>±1.0%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±2.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>88 ~ 264VAC auto switch 120 ~ 370VDC<br>47 ~ 63Hz<br>72%<br>75%<br>76%<br>77%<br>78%<br>78%<br>0.8A/115VAC 0.5A/230VAC<br>COLD START 30A/230VAC<br>Above 105% rated output power<br>5.5 ~ 6.75V<br>13.2 ~ 16.2V<br>16.5 ~ 20.25V<br>26.4 ~ 32.4V<br>29.7 ~ 36.45V<br>52.8 ~ 64.8V<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>Shut down o/p voltage, re-power on to recover<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>-20 ~ +85<br>, 10 ~ 95% RH<br>℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)<br>10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>547Khrs min. MIL-HDBK-217F (25<br>)<br>℃<br>101.6*65.8*23.5mm (L*W*H)<br>0.16Kg; 90pcs/15.8Kg/1.02CUFT<br>500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load<br>70ms/230VAC 12ms/115VAC at full load<br>-10 ~ +60<br>(Refer to "Derating Curve")<br>℃<br>20 ~ 90% RH non-condensing<br>**SAFETY STANDARDS**<br>ANSI/AAMI ES60601-1, TUV EN60601-1, IEC60601-1 approved<br>Compliance to EN55011 (CISPR11) Class B, EN61000-3-2,-3<br>Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN60601-1-2, medical level, criteria A<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCE Note.3**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:SHORT<br>I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**(Note 4)**<br>**PROTECTION**<br>℃<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>Earth leakage current < 200 A/264VAC<br>μ<br>**ISOLATION LEVEL**<br>Primary-Secondary: 2xMOPP, Primary-Earth:1xMOPP<br>NRND<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25 _ of ambient temperature.<br>2. Ripple & noise are measured at20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance: includes set up tolerance, line regulation and load regulation.<br>4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)<br>5. When the input viotage is less than 40VAC, the SPS may exhibit degradation of performance. The final product manufacturers must re-confirm this<br>deviation that does not affect basic safety or essential performance.||**MPS-30-5**|**MPS-30-12**|**MPS-30-15**|**MPS-30-24**|**MPS-30-27**|**MPS-30-48**| ||**DC VOLTAGE**|5V|12V|15V|24V|27V|48V| ||**RATED CURRENT**|5A|2.5A|2A|1.2A|1.1A|0.6A| ||**CURRENT RANGE**|0 ~ 5A|0 ~ 2.5A|0 ~ 2A|0 ~ 1.2A|0 ~ 1.1A|0 ~ 0.6A| ||**RATED POWER**|25W|30W|30W|28.8W|29.7W|28.8W| ||**RIPPLE & NOISE (max.) Note.2**|80mVp-p<br>NRND|120mVp-p<br>NRND|150mVp-p<br>NRND|240mVp-p<br>NRND|240mVp-p|240mVp-p| ||**VOLTAGE TOLERANCE Note.3**|±3.0%<br>NRND|±3.0%<br>NRND|±3.0%<br>NRND|±3.0%<br>NRND|±3.0%|±2.0%| ||**LINE REGULATION**|±1.0%<br>NRND|±1.0%<br>NRND|±0.5%<br>NRND|±0.5%<br>NRND|±0.5%|±0.5%| ||**LOAD REGULATION**|±2.0%<br>NRND|±1.0%<br>NRND|±1.0%<br>NRND|±1.0%<br>NRND|±1.0%|±1.0%| ||**SETUP, RISE TIME**|500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load<br>NRND|||||| ||**HOLD UP TIME (Typ.)**|70ms/230VAC 12ms/115VAC at full load<br>NRND|||||| ||**VOLTAGE RANGE**|88 ~ 264VAC auto switch 120 ~ 370VDC<br>NRND|||||| ||**FREQUENCY RANGE**|47 ~ 63Hz<br>NRND|||||| ||**EFFICIENCY (Typ.)**|72%<br>NRND|75%<br>NRND|76%<br>NRND|77%<br>NRND|78%|78%| ||**AC CURRENT (Typ.)**|0.8A/115VAC 0.5A/230VAC<br>NRND|||||| ||**INRUSH CURRENT (Typ.)**|COLD START 30A/230VAC<br>NRND|||||| ||**LEAKAGE CURRENT**|Earth leakage current < 200 A/264VAC<br>μ<br>NRND|||||| ||**OVERLOAD**|Above 105% rated output power<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>NRND|||||| ||**OVER VOLTAGE**|5.5 ~ 6.75V<br>13.2 ~ 16.2V<br>16.5 ~ 20.25V<br>26.4 ~ 32.4V<br>29.7 ~ 36.45V<br>52.8 ~ 64.8V<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>NRND|||||| ||**OVER TEMPERATURE**|Shut down o/p voltage, re-power on to recover|||||| ||**WORKING TEMP.**|-10 ~ +60<br>(Refer to "Derating Curve")<br>℃|||||| ||**WORKING HUMIDITY**|20 ~ 90% RH non-condensing|||||| ||**STORAGE TEMP., HUMIDITY**|-20 ~ +85<br>, 10 ~ 95% RH<br>℃|||||| ||**TEMP. COEFFICIENT**|±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)|||||| ||**VIBRATION**|10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes|||||| ||**SAFETY STANDARDS**|ANSI/AAMI ES60601-1, TUV EN60601-1, IEC60601-1 approved|||||| ||**ISOLATION LEVEL**|Primary-Secondary: 2xMOPP, Primary-Earth:1xMOPP|||||| ||**WITHSTAND VOLTAGE**|I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:SHORT|||||| ||**ISOLATION RESISTANCE**|I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃|||||| ||**EMC EMISSION**|Compliance to EN55011 (CISPR11) Class B, EN61000-3-2,-3|||||| ||**EMC IMMUNITY**|Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN60601-1-2, medical level, criteria A|||||| ||**MTBF**|547Khrs min. MIL-HDBK-217F (25<br>)<br>℃|||||| ||**DIMENSION**|101.6*65.8*23.5mm (L*W*H)|||||| ||**PACKING**|0.16Kg; 90pcs/15.8Kg/1.02CUFT|||||| ||℃<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25 _ of ambient temperature.<br>2. Ripple & noise are measured at20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance: includes set up tolerance, line regulation and load regulation.<br>4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)<br>5. When the input viotage is less than 40VAC, the SPS may exhibit degradation of performance. The final product manufacturers must re-confirm this<br>deviation that does not affect basic safety or essential performance.||||||| _File Name:MPS-30-SPEC 2015-08-06_ **MPS - 30 series** ## 30W Single Output for Medical Type **==> picture [511 x 688] intentionally omitted <==** **----- Start of picture text -----**<br> Mechanical Specification Unit:mm<br>101.6<br>66.1<br>3.2 95.2<br>4<br>CN2 3<br>2<br>1<br>5<br>4<br>CN1 3<br>2<br>1<br>FUSE*2<br>T2.5A 250V<br>AC Input Connector (CN1) : Molex 41791-5 or equivalent DC Output Connector (CN2) : Molex 41791-4 or equivalent<br>Pin No. Assignment Mating Housing Terminal Pin No. Assignment Mating Housing Terminal<br>1 FG 1,2 -V Molex 2139 Molex 2478<br>2,4 No Pin Molex 2139 Molex 2478 3,4 +V or equivalent or equivalent<br>3 AC/N or equivalent or equivalent<br>5 AC/L<br>: Grounding Required<br>CN1:Pin 1 is safety ground<br>Block Diagram<br>fosc : 100KHz<br>EMI RECTIFIERS POWER RECTIFIERS +V<br>I/P FILTER & SWITCHING & -V<br>FILTER FILTER<br>PWM<br>CONTROL DETECTION<br>FG CIRCUIT<br>CROWBAR<br>OVP<br>Derating Curve Static Characteristics<br>32 350<br>100<br>28 300<br>80<br>24 250<br>60 20 200<br>16 150<br>40<br>12 100<br>20<br>8 50<br>-10 0 10 20 30 40 50 60 (HORIZONTAL) 60 80 100 120 140 160 180 200 220 240 264<br>AMBIENT TEMPERATURE ( ℃ ) INPUT VOLTAGE (V) 60Hz<br>4-ψ3.2<br>M3 L=6mm<br>NRND<br>LOAD (%) OUTPUT VOLTAGE (V) OUTPUT RIPPLE (mVp-p)<br>3.2<br>18<br>65.8 62.6 51.4<br>23.5 max.<br>2 max.<br>**----- End of picture text -----**<br> _File Name:MPS-30-SPEC 2015-08-06_
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →